Extended Reach, Client-Side SFP, Multi-Rate, Multi-Protocol, DWDM, 3R Transponder WaveReady Transponder 740 XLR

Similar documents
Long Reach, Client-Side SFP, Multi-Rate, Multi-Protocol, CWDM, 3R Transponder WaveReady Transponder 740 LR CWDM

WaveReady WRT Gbps Extended-Reach DWDM Tunable Transponder with XFP Client Interface

2.5 Gb/s Transponder with Mux/Demux (1310 and 1550 nm) 54TR Series

Cisco 10GBASE Dense Wavelength-Division Multiplexing SFP+ Modules

Cisco 10GBASE Dense Wavelength-Division Multiplexing XFP Modules

Hardware Specifications

SPDxx040100D SFP+ Dual Fibre DWDM 100GHz DWDM / 40 km / 10 Gigabit Ethernet

Industrial Diode Laser (IDL) System IDL Series

Tunable SFP+ DWDM 10G 80Km ZR SLSSD-10GE-ZR-T

Fibre Channel Fiber-to-Fiber Media Converters

MTS/T-BERD Platforms WDMPMD Module

LambdaFLEX Zero Chirp Tunable XFP Module TL8800ZPCND

LambdaFLEX Tunable XFP Module

Optical Add/Drop Cards

SFCxxB24GExD SFP Dual Fibre CWDM CWDM / 24dB / Gigabit Ethernet

SPCxxB10100D SFP+ Dual Fiber CWDM CWDM / 10dB / 10 Gigabit Ethernet

LambdaFLEX Negative Chirp Tunable XFP Module TL8900NACND

SFCxxB16GExD SFP Dual Fibre CWDM ITU CWDM / 16dB / Gigabit Ethernet

MTS/T-BERD 8000 Platform Optical Spectrum Analyzer Modules

40G SWDM4 MSA Technical Specifications Optical Specifications

Pluggable Transceivers Installation Guide

CHP Max Headend Optics Platform CHP CORWave II

Fibre Optic Modem ODW-611

SFP-10G-LR (10G BASE-LR SFP+) Datasheet

ED5229GT-E Series. Page 1 of 8

CFPQD010C10D CFP Dual Fibre 1310nm* / 10km / 100GBASE-LR4 & OTN OTU4

CFMFFxxxx-2xx User s Guide Slide-in-Module Media Converter Fast Ethernet, ATM, SONET, or Gigabit

10G SFP+ Modules. 10G SFP+ Module Series

Intel Ethernet SFP+ Optics

ED5229GT-E/GTRE Series

Headend Optics Platform (CH3000)

Benchtop/Rackmount Programmable Switches. Key Features & Benefits. SB/SC/SCG Series. Applications INSTRUMENTATION CATALOGUE - 73

Industrial 10/100 Base-TX to 100 Base-FX Media Converter NS-200AFC-T/NS-200AFCS-T/NS-200AFCS-60T +12 ~ +48

OC-48/STM-16 Bi-directional SFP Transceiver (40km) RBT25SI2

10Gbps 10km Range SFP+ Optical Transceiver

Fibre Optic Modem ODW-622

40GBASE-ER4 optical budget

40G SWDM4 MSA Technical Specifications Optical Specifications

Opti Max Nodes Digital Return System

10Gbps 10km Range 1310nm SFP+ Optical Transceiver

DWDM Cards. 6.1 DWDM Card Overview CHAPTER

MICROSENS. Fast Ethernet Switch Modul 4x 10/100Base-TX, 1x 100Base-FX. Description. Features

HDO701 FIBRE OPTIC TRANSMITTER

FTS-S12G-B53Y-005. SFP 1000Base-LX, BiDi, 1550/1310nm, single-mode, 5km

10Gbps SFP+ Optical Transceiver, 10km Reach

EMPOWERFIBER 10Gbps 2km SFP+ Optical Transceiver EPP C

InterReach Fusion Data Sheet

FTX-S1XG-S55L-040DI. XFP 10GBase-ER, 1550nm, single-mode, 40km

OmniStar GX2 Headend Optics Platform

FTS-M12G-S85L-55M. SFP 1000Base-SX, 850nm, multi-mode, 550m

SPECIAL SPECIFICATION :1 Video (De) Mux with Data Channel

LONWORKS Fibre Optic Converter

10Gb/s SFP+ ER 1550nm Cooled EML with TEC, PIN Receiver 40km transmission distance

ODW-621. RS-232 Point-to-point applications

Prolabs SFP-10G-AOCxM

LONWORKS Fibre Optic Router

Model 755U Optical Transmitter DWDM, up to 20 km, Low Distortion, Wideband

SNS-XFP-10GD-LR 10 Gbps Multi-Rate XFP Transceivers OC192/STM-64, 10GE or 10G FC 1310nm, Single-Mode 10Km, with Digital Diagnostics.

F M1SDI 1 Ch Tx & Rx. HD SDI Fiber Optic Link with RS 485. User Manual

Spec Sheet. InterReach Fusion Wideband 2.5 GHz WiMAX. In-Building Wireless Networking System. Product Highlights

PRE-QSFP-LR4L 100G QSFP 28 Dual Range Optical Transceiver, 10km. Product Features: General Product Description:

SMF Ad Hoc report. Pete Anslow, Ciena, SMF Ad Hoc Chair. IEEE P802.3bm, Geneva, September 2012

XFP Optical Transceiver

MTS/T-BERD 8000 Platform

10Gb/s 40km DWDM XFP Optical Transceiver

Fibre optic router for TP/FT-10 LRW-112PP

MX/HD-SDI-3G. Transmit HD-SDI-3G signals over Fiber

Prisma II Optical Amplifiers for Fiber to the Home (FTTH)

GPON EDFA with WDM for IP(OLT) Wavelengths Multiple Optical Outputs

PowerBit F10. Data Sheet Gb/s Intensity Modulator with Low Drive Voltage. Features:

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter

400G-FR4 Technical Specification

FTS-R27G-S31L-002DI. Multirate SFP 125Mbps-2.67Gbps, 1310nm, single-mode, 2km

OC-48/STM-16 SFP Transceiver (SR) RSP25SS1

IEC G-port Gigabit smart rackmount Ethernet switches STAT PWR1 PWR2 FAULT FDX/HDX MODE. Warranty

10G- XFP- LR- AO. 10Gbs XFP Transceiver

40GBd QSFP+ SR4 Transceiver

Part Number Transmitter Output Power Receiver Sensitivity Reach Temp DDM RoHS. Logic Symbol Name/Description Note 1 - GND Module Ground 1

Cisco ONS Exposed Faceplate Mux/Demux 48-Channel Extended Bandwidth Patch Panel and Splitter Coupler Module

3G-SDI Extender via Single Mode Fiber LC Simplex Connector Extends 3G-SDI Link Up To 20 Kilo Meters

Model DM8000-U Optical Transmitter Direct Modulation, DWDM, Low Distortion, Wideband

100G-FR and 100G-LR Technical Specifications

DVBus and Multiplexer and demultiplexer assemblies for video channels, with bidirectional audio and data USER MANUAL

! "#$ ' % & % & ' ( )!' *!+, ( *-"(! './ 0 / 0/ $ 1/ 2$3 1

100GBASE-DR2: A Baseline Proposal for the 100G 500m Two Lane Objective. Brian Welch (Luxtera)

Hardware Specifications

Model GS Port Node 1 GHz with 65/86 MHz split

3Gb/s, HD and SD and ASI/DVB and SMPTE-310M 8x8 video router ALL RIGHTS RESERVED

FORWARD PATH TRANSMITTERS

FX-1310-F10 10Gbps XFP Optical Transceiver, 10km Reach

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

OmniStar GX2 Headend Optics Platform GX2 LM1000E Series

User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W

H5000 Outdoor Mini Virtual HUB

FOM-9010, FOM-9011 and FOM-9012

User s Guide TN-GB-SM512. Gigabit Interface Converter (GBIC) Transceiver Modules

Dual Fiber SFP Series

10G- XFP- SR- AO. 10Gbs XFP Transceiver

Product Specification XFP 10G LR 20km LC Optical Transceiver

Small Form-factor Pluggable (SFP) Optical Module Cartridges (Ethernet) For Densité Frames and Grass Valley/Telecast Standalone Fiber Products

Transcription:

COMMUNICATIONS MODULES & SUBSYSTEMS Extended Reach, Client-Side SFP, Multi-Rate, Multi-Protocol, DWDM, 3R Transponder WaveReady Transponder 740 XLR Key Features Client-side SFP modules support either single-mode fiber (SMF) or multimode fiber (MMF) Automatic bit-rate detection and reporting Multiple protocols supported at discrete bit rates of 125 Mb/s to 3.125 Gb/s Network optics support 16 ITU wavelengths on a 100 GHz grid over distances up to 180 km, without dispersion compensation or amplification Facility loopback functionality on both network and client sides Remote management via SNMP traps or TL1 3R functionality at all supported bit rates and protocols Applications Wavelength services Metro optical access overlay Storage area network (SAN) and GigE extension services Compliance FCC Part 15 (Class A); UL 60950 3rd Edition, December 2000; CAN/CSA-C22.2 No. 950-95; NEBS Level 3; GR-63-CORE; GR-1089-CORE; GR-78-CORE; CE; IEC 60950; ETS300-386; EN 55022 (Class B); 73/23/EEC The WaveReady Transponder 740 (WRT-740) is a multi-rate, multi-protocol, auto-lock module that translates optical signals between a variety of client-side interfaces into a long-reach, single-mode, dense wavelength division multiplexing (DWDM) interface. This module includes small form factor pluggable (SFP) modules on the client side, loopback, and 3R (reshape, retime and reamplify/regenerate) functionality. SFP modules optimized for a wide range of protocols are available for singlemode and multimode fiber. Supported protocols include 100Base-FX Ethernet, Gigabit Ethernet (GigE), ESCON, Fibre channel, FICON, and OC-3 to OC-48. Supported data rates range from 125 Mb/s to 3.125 Gb/s. The WRT-740's bit-rate and protocol independence gives service providers the flexibility to meet the shifting service demands of customers without changing installed equipment. Remote management lowers operating, administration and management expenditures (OPEX). A WaveReady communications module manages the WRT- 740 with TL1 and a command line or telnet interface, or with TL1 or simple network management protocol (SNMP) and the JDSU Node Manager software. An embedded supervisory channel on the network side is also available for remote management of standalone modules without the cost of extra fiber or an extra WaveReady communications module. Full 3R functionality allows multiple WRT-740 modules to be deployed in series for very long reach applications. Loopback facilitates fault isolation and troubleshooting. NORTH AMERICA: 800 498-JDSU (5378) WORLDWIDE: +800 5378-JDSU WEBSITE: www.jdsu.com

2 Point-to-Point Four-Channel DWDM Link WaveReady 3500-F Shelf WRT-740 WaveReady 3500-F Shelf WRT-740 Typical Link Budget Data Rate Minimum Rx Power Total Power Budget Maximum Distance OC-48-28.5 dbm 27.9 db 111 km Gigabit Ethernet -30 dbm 29.4 db 117 km Point-to-point Single Channel DWDM Link Typical Link Budget Data Rate Minimum Rx Power Total Power Budget Maximum Distance OC-48-28.5 dbm 33.5 db 134 km Gigabit Ethernet -30 dbm 35 db 140 km

3 Network Optical Specifications Parameter Specifications Optical Path between Transmitter and Receiver Connectors Dispersion at OC-48 Maximum 3240 ps/nm Optical return loss of cable plant, including any connectors Minimum 24 db Discrete reflectance between transmit and receive connectors Maximum 27 db Maximum link budget at OC-48 including dispersion Minimum 31.5 db Typical 36 db Transmitter Wavelength range on ITU grid 1530 to 1561 nm Frequency range (32 frequencies, 100 GHz spacing) 192.1 to 195.9 THz Wavelength accuracy Maximum 100 pm Mean output power Minimum 5 dbm Typical 7 dbm Maximum 10 dbm Extinction ratio Minimum 8.2 db Typical 9.5 db 1 Receiver Sensitivity at 100BaseF to GE, BER=1x10-10 Minimum -30 dbm Sensitivity at OC-48, BER=1x10-10 Minimum -28.5 dbm Overload Minimum -8 dbm 2 OSNR tolerance at BER=1x10-12 Minimum 20 db 3 Optical path penalty on standard single-mode fiber Maximum 2 db 4 Reflectance of receiver at receiver connector Maximum -27 db LOS activation threshold Typical -32 dbm LOS deactivation threshold Typical -30 dbm Note: All specifications are guaranteed over the life, operating temperatures, wavelength range, and input voltage range specified. This product should be deployed in accordance with each company's deployment directives. 1. At OC-48 2. Management communications at OC-3 require input power less than -15 dbm 3. With receive power of -27 dbm with no other signal impairments at EOL over all temperature ranges 4. Dispersion penalty only

4 Other Specifications Parameter Condition Specifications Electrical Power consumption Over temperature range EOL Typical 16.5 W Maximum 20 W Supply voltage 1 Minimum 38 V Typical 48 V Maximum 60 V Environmental Storage temperature -40 to 85 C Ambient operating temperature -5 to 55 C short term, 96 hours continuous. -5 to 55 C No more than 15 days per year. Humidity Non-condensing 5 to 95% Mechanical Weight (approximate) 1.4 kg (3.1 pounds) Dimensions (WxHxD) 25.4 x 223.5 x 175 mm (1.0 x 6.89 x 8.8 inches) Mounting options WaveReady 3500-F or fan-equipped WaveReady 3100 shelf in standard 19- or 24-inch rack 1. The DC power supply must be -48 V SELV output and certified by a nationally recognized test laboratory (NRTL) Interface Specifications Parameter Provisioning, operations, administration, maintenance Front panel LEDs Front panel ports Alarms Specification Via the WaveReady Communication Module 200. Remote management: SNMP and TL1 command mode through JDS Uniphase Node Manager software or TL1 through telnet or command-line application or SNMP. Communication with remote modules through an embedded supervisory channel. CARD (power), MAJ/CRIT (major or critical alarm), MIN (minor alarm), LOS B, LOS D, LOS F (loss of lock) LOOPBK (loopback), MGT (management). Client side ports A and B single mode or multimode fiber (SMF or MMF), SFP1, SFP2, SFP3, SFP4 or SFP5. Network side ports: C and D, SMF. CARD (power), MAJ/CRIT (major or critical alarm), MIN (minor alarm), LOS B, LOS D (loss of lock). Alarm relay open under normal operation. Relay closed when power is off and alarm is active.

5 Compatibility of Client SFPs Protocol Bit Rate SFP SMF Fiber 100Base-FX Ethernet 125 Mb/s SFP1 and SFP2 OC-3 IR-1/STM-1 S-1.1 155.52 Mb/s SFP1 and SFP2 ESCON 200 Mb/s SFP1 and SFP2 D1 video 270 Mb/s SFP1 and SFP2 OC-12/STM-4 S-4.1 622.08 Mb/s SFP1 and SFP2 FICON LX single mode 1.0625 Gb/s SFP1 Fibre channel 100-SMLL-L 1.0625 Gb/s SFP1 Gigabit Ethernet 1000Base-LX 1.250 Gb/s SFP1 Fibre channel 200-SMLL-I 2.125 Gb/s SFP1 OC-48/STM-16 I-16 2.48832 Gb/s SFP1 OC-48 FEC 2.7 Gb/s SFP1 MMF Fiber 100Base-FX Ethernet 125 Mb/s SFP2 ESCON 200 Mb/s SFP2 or SFP1 1 FICON LX 1.0625 Gb/s SFP3 or SFP1 1 FICON SX 1.0625 Gb/s SFP4 Fibre channel 100-M5-SN-I 1.0625 Gb/s SFP4 Gigabit Ethernet 1000Base-SX 1.250 Gb/s SFP4 1. Due to the dual media (single-mode and multimode) support of this transmitter, fulfillment of this protocol requires a single-mode fiber offset launch mode conditioning patch cord. The offset launch mode conditioning cable lowers the launch power by 0.5 db and incurs a similar penalty on the sensitivity.

6 Ordering Information For more information on this or other products and their availability, please contact your local JDSU account manager or JDSU directly at 1-800-498-JDSU (5378) in North America and +800-5378-JDSU worldwide or via e-mail at customer.service@jdsu.com. Sample: WRT-740DT240B-153 WRT-740DT240B- Code ITU Channel/Frequency 1 135 193.5 THz/1549.32 nm 137 193.7 THz/1547.72 nm 144 194.4 THz/1542.14 nm 145 194.5 THz/1541.35 nm 146 194.6 THz/1540.56 nm 147 194.7 THz/1539.77 nm 148 194.8 THz/1538.98 nm 149 194.9 THz/1538.19 nm 152 195.2 THz/1535.82 nm 153 195.3 THz/1535.04 nm 154 195.4 THz/1534.25 nm 155 195.5 THz/1533.47 nm 156 195.6 THz/1532.68 nm 157 195.7 THz/1531.90 nm 158 195.8 THz/1531.12 nm 159 195.9 THz/1530.33 nm 1. Other channels are available upon request. SFP Sample: WRT-SFPS12SB1310 WRT-SFP Code S24SB1310 S12SB1310 M20SB0850 S20SB1310 Model SFP1 SFP2 SFP3 SFP4 All statements, technical information and recommendations related to the products herein are based upon information believed to be reliable or accurate. However, the accuracy or completeness thereof is not guaranteed, and no responsibility is assumed for any inaccuracies. The user assumes all risks and liability whatsoever in connection with the use of a product or its application. JDSU reserves the right to change at any time without notice the design, specifications, function, fit or form of its products described herein, including withdrawal at any time of a product offered for sale herein. JDSU makes no representations that the products herein are free from any intellectual property claims of others. Please contact JDSU for more information. JDSU, Waveready, and the JDSU logo are trademarks of JDS Uniphase Corporation. Other trademarks are the property of their respective holders. 2005 JDS Uniphase Corporation. All rights reserved. 10143107 Rev. 004 0808 WRT740.DS.CMS.AE NORTH AMERICA: 800 498-JDSU (5378) WORLDWIDE: +800 5378-JDSU WEBSITE: www.jdsu.com