NEMA JM/JP Close Coupled Pump Motors. Features Include: NEMA MG1-Part 31 inverter duty 15:1 constant torque, 20:1 variable torque.
|
|
- Esmond Wheeler
- 5 years ago
- Views:
Transcription
1 W Series JM/JP - TEFC Cast , JM/JP Pump Motors. Features Include: MG1-Part 31 inverter duty 15:1 constant torque, 20:1 variable torque 1 HP to 30 HP 40 HP to 75 HP 1.25 service factor at 60Hz, 1.0 service factor at 50Hz temperature rise washdown duty enclosure both brackets for increased Dual rated 60/50Hz at same HP Split conduit box is 90 degree rotatable CSA approved for Class I; Division 2; Groups A, B, C & D, Zone 2; Groups IIA & IIB T3 on sine wave power Internal tropicproof 3 year warranty 32 : RF - Removable Feet TM - Thermistors
2 143JM-365JM - TEFC C-Face With Removable Feet Frames 44 RF 44 RF 1 RF RF RF 44 RF 44 RF 1.5 RF RF RF RF RF 2 RF RF RF RF RF 3 RF RF RF RF RF RF 5 RF RF RF RF RF RF RF 7.5 RF RF 10 RF RF RF Discount Category 56 33
3 143JM-365JM - TEFC C-Face With Removable Feet Discount Category 56 Frames 34
4 W Series JP - TEFC C-Face With Removable Feet Frames RF 1 RF RF RF RF RF 1.5 RF RF RF RF RF 2 RF RF RF RF RF 3 RF RF RF RF RF RF 5 RF RF RF RF RF RF RF 7.5 RF RF 10 RF RF RF Discount Category 56 35
5 W Series JP - TEFC C-Face With Removable Feet Discount Category 56 Frames 36
6 JM/JP TEFC Dimensions Frame Sizes Frame U AH AJ AK BB BD Max. No. BF Size Bolt Pen. Allow EL EM Size Drill Depth Max. EN Bolt Pen. Allow. EP EQ ER R Keyseat Frame U AH AJ AK BB BD Max. No. BF Size Bolt Pen. Allow EL EM Size Drill Depth Max. EN Bolt Pen. Allow. EP EQ ER R ES Keyseat *For standard foot dimensions see page 96 JM Dimensions JP Dimensions ES S S ET ET 95
7 IP (Ingress Protection) IEC Metric Motors IP 5 5 Protection Against Solid Objects Protection Against Liquids # Brief Description* # Brief Description* 0 No special protection 0 No special protection 1 2 solid objects greater than solid objects greater than Accidental or inadvertent contact with or approach to live and moving parts inside the enclosure by a large surface of the human body, such as a or approach to live or moving parts inside the enclosure. Ingress of solid 1 2 dripping water dripping shall have no harmful effect. Vertically dripping water shall have no harmful effect when the machine is tilted in 3 solid objects greater than Contact with or approach to live or moving parts inside the enclosure by ools or wires exceeding 2.5 mm in diameter. Ingress of solid objects 3 spraying water Vertically dripping water shall have no harmful effect when the machine is tilted in 4 solid objects greater than Contact with or approach to live or moving parts inside the enclosure by wires or strips of thickness greater 4 splashing water harmful effect 5 Contact with or approach to live or moving parts inside the enclosure. Ingress of dust is not totally prevented but interfere with satisfactory operation of the machine. 5 water jets machine from any direction shall have no harmful effect. 6 Contact with or approach to live or moving parts inside the enclosure. No ingress of dust 6 heavy seas projected in powerful jets shall not enter 102
8 Mounting Codes IEC Mounting Codes Mounting Codes 103
Small and Medium Industrial Motors
Small and Medium Industrial Motors PRODUCT ABBREVIATIONS XT = Extra Tough EM = E-Master (EPAct compliant) EMT = E-Master, Extra Tough XE = Premium Efficient NEMA PREMIUM/CEE The Consortium for Energy Efficiency
More information70 Series End Mount 8700 Style NEMA Frame Sizes 182TC through 256TC/UC Torque Ratings: 10 to 105 lb-ft
70 Series End Mount 8700 Style EMA Frame Sizes 182 through 256/U Ratings: 10 to 105 Dripproof EMA 2, SA 2, IP43 70 Series Specifications: Reaction ime: 20-25 milliseconds (release and set) AK: 8.5 Register
More informationConsiderations for Specifying, Installing and Interfacing Rotary Incremental Optical Encoders
Considerations for Specifying, Installing and Interfacing Rotary Incremental Optical Encoders Scott Hewitt, President SICK STEGMANN, INC. Dayton, OH www.stegmann.com sales@stegmann.com 800-811-9110 The
More informationModular Lube Lubrication Systems System Controls
Model 84501 Program Timer Solid State Designed to control the lubrication cycle frequency of air-operated single-stroke pumps. Timer turns pump on/off at programmed intervals via a 3-way or 4-way air solenoid
More informationXML LED X M L L E D. Explosionproof Linear LED Lighting
LED Class I, Division 1, Groups C & D Class I, Division 2, Groups C & D Class II, Division 1, Groups E, F & G Class III Simultaneous Presence UL 844 Hazardous Locations IEC Ex d Zone 1 Equivalent UL 924
More informationWIRE AND CABLE FIRE TESTS
TEST CSA C22.2 No 2556-13 Section 9.4 (FV-2/VW-1) (Small Scale Vertical) # OF VALUES REPORTED FOOTAGE REQUIRED 3 3 pieces: 24 each 5 7 days PERFORMANCE TIME CSA-FT1 (Small Scale Vertical) 3 5 pieces: 24
More informationMVSI-TS. Technical features
Technical features Power supply Three-phase voltage from 48V to 690V, 50Hz or 60Hz; suitable for use with an inverter from 20Hz to the base frequency, with constant torque load profile. Polarity 4, 6 and
More informationOperating Manual. Automated Gear. Apollo Design Technology, Inc Fourier Drive Fort Wayne, IN USA
Operating Manual Automated Gear Apollo Design Technology, Inc. 4130 Fourier Drive Fort Wayne, IN 46818 USA PH: +01(260)497-9191 FX: +01(260)497-9192 www.apollodesign.net 11-25-09 5-6 POWERING UP THE RIGHT
More information9 Control Equipment. Measurement- and Control Equipment Series 8214, 8218
9 Control Equipment Measurement- and Control Equipment Series, Explosion protection to CENELEC IEC Can be used in Zone 1 and Zone 2 Designed for panel mounting Enclosure material : Polyester resin : Aluminium,
More informationSoft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit
DATASHEET - S811+N66N3S Delivery program Soft starter, 66 A, 200-600 V AC, Us= 24 V DC, with control unit, Frame size N Part no. S811+N66N3S Catalog No. 168978 Eaton Catalog No. S811PLUSN66N3S EL-Nummer
More informationAmphenol. Circular. Connectors C 16-1 / C Circular Connectors. Amphenol-Tuchel Electronics
Amphenol C 6- / C 6- Circular Circular Connectors Connectors Amphenol-Tuchel Electronics General information We reserve the right to change the design due to improvement in quality, development or production
More informationP Output Ratings. Dimensions and Weights. Prime Rating
- P220-3 #FGWILSON_GENSET_IMAGE Output Ratings Voltage, Frequency Prime Standby 400V, 50 Hz 480V, 60 Hz kva 200 220 kw 160 176 kva - - kw - - Ratings at 0.8 power factor. Please refer to the output ratings
More informationP Output Ratings. Dimensions and Weights. Prime Rating
- P165-5 #FGWILSON_GENSET_IMAGE Output Ratings Voltage, Frequency Prime Standby 400V, 50 Hz 480V, 60 Hz kva 150 165 kw 120 132 kva 168.8 187.5 kw 135 150 Ratings at 0.8 power factor. Please refer to the
More informationP88-3. Output Ratings. Dimensions and Weights. Prime Rating
- P88-3 #FGWILSON_GENSET_IMAGE Output Ratings Voltage, Frequency Prime Standby 400V, 50 Hz 480V, 60 Hz kva 80 88 kw 64 70.4 kva 90 100 kw 72 80 Ratings at 0.8 power factor. Please refer to the output ratings
More informationP Output Ratings. Dimensions and Weights. Prime Rating
- #FGWILSON_GENSET_IMAGE Output Ratings Voltage, Frequency Prime Standby 400V, 50 Hz 480V, 60 Hz kva 150 165 kw 120 132 kva kw Ratings at 0.8 power factor. Please refer to the output ratings technical
More informationP Output Ratings. Dimensions and Weights. Prime Rating
- P150-5 #FGWILSON_GENSET_IMAGE Output Ratings Voltage, Frequency Prime Standby 400V, 50 Hz 480V, 60 Hz kva 135 150 kw 108 120 kva 150 165 kw 120 132 Ratings at 0.8 power factor. Please refer to the output
More informationP Output Ratings. Dimensions and Weights. Prime Rating
- #FGWILSON_GENSET_IMAGE Output Ratings Voltage, Frequency Prime Standby 400V, 50 Hz 480V, 60 Hz kva 180 200 kw 144 160 kva 200 218.8 kw 160 175 Ratings at 0.8 power factor. Please refer to the output
More informationP550-3L. Output Ratings. Dimensions and Weights. Prime Rating
- P550-3L Optional LS Upgrade #FGWILSON_GENSET_IMAGE Output Ratings Voltage, Frequency 400V, 50 Hz 480V, 60 Hz Prime Standby kva 500 550 kw 400 440 kva kw Ratings at 0.8 power factor. Please refer to the
More informationP65-5. Output Ratings. Dimensions and Weights. Prime Rating
- P65-5 #FGWILSON_GENSET_IMAGE Output Ratings Voltage, Frequency Prime Standby 400V, 50 Hz 480V, 60 Hz kva 60 65 kw 48 52 kva 68.8 75 kw 55 60 Ratings at 0.8 power factor. Please refer to the output ratings
More informationP400-3L. Output Ratings. Dimensions and Weights. Prime Rating
- P400-3L Optional LS Upgrade #FGWILSON_GENSET_IMAGE Output Ratings Voltage, Frequency 400V, 50 Hz 480V, 60 Hz Prime Standby kva 350 400 kw 280 320 kva kw Ratings at 0.8 power factor. Please refer to the
More informationP Output Ratings. Dimensions and Weights. Prime Rating
#DEALER_LOGO P275-5 #FGWILSON_GENSET_IMAGE Output Ratings Voltage, Frequency Prime Standby 400/230V, 50 Hz 480/277V, 60 Hz kva 250 275 kw 200 220 kva kw Ratings at 0.8 power factor. Please refer to the
More informationRatings at 0.8 power factor. Please refer to the output ratings technical data section for specific generator set outputs per voltage.
- P2000/P2250E #FGWILSON_GENSET_IMAGE Output Ratings Voltage, Frequency Prime Standby 400V, 50 Hz 480V, 60 Hz kva 2000 2250 kw 1600 1800 kva kw Ratings at 0.8 power factor. Please refer to the output ratings
More informationP1000P1/P1100E1 50Hz
- P1000P1/P1100E1 50Hz #FGWILSON_GENSET_IMAGE Output Ratings Voltage, Frequency Prime Standby 400V, 50 Hz 480V, 60 Hz kva 1000 1100 kw 800 880 kva kw Ratings at 0.8 power factor. Please refer to the output
More informationP Output Ratings. Dimensions and Weights. Prime Rating
#DEALER_LOGO P660-3 #FGWILSON_GENSET_IMAGE Output Ratings Voltage, Frequency Prime Standby 400/230V, 50 Hz 480/277V, 60 Hz kva 600 660 kw 480 528 kva kw Ratings at 0.8 power factor. Please refer to the
More informationP800P1/P900E1. Output Ratings. Dimensions and Weights. Prime Rating
#DEALER_LOGO P800P1/P900E1 #FGWILSON_GENSET_IMAGE Output Ratings Voltage, Frequency Prime Standby 400/230V, 50 Hz 480/277V, 60 Hz kva 800 900 kw 640 720 kva 844 938 kw 675.2 750.4 Ratings at 0.8 power
More informationP Output Ratings. Dimensions and Weights. Prime Rating
#DEALER_LOGO P400-3 #FGWILSON_GENSET_IMAGE Output Ratings Voltage, Frequency Prime Standby 400/230V, 50 Hz 480/277V, 60 Hz kva 350 400 kw 280 320 kva kw Ratings at 0.8 power factor. Please refer to the
More informationP1350P1/P1500E1 50Hz
- P1350P1/P1500E1 50Hz #FGWILSON_GENSET_IMAGE Output Ratings Voltage, Frequency Prime Standby 400V, 50 Hz 480V, 60 Hz kva 1350 1500 kw 1080 1200 kva kw Ratings at 0.8 power factor. Please refer to the
More informationHOG 86. The incremental HeavyDuty encoder for highest demands
HOG 86 The incremental HeavyDuty encoder for highest demands Extremely robust. Failsafe in any environment The solid, extremely sturdy housing with minimum 10 mm wall thickness is a prerequisite design
More informationHorn loudspeaker, Ex proof, short/long flare
Horn loudspeaker, Ex proof, short/long flare LH3 UC25XS, LH3 UC25XL en Installation note Horn loudspeaker, Ex-proof, short/long flare Installation en 3 1 Installation 1 2 Figure 1.1 Figure 1.2 4X Figure
More informationProduct Data Sheet 4656 ZW
The engineer's choice 4656 ZW INDEX 1 General... 3 2 Mechanics... 3 2.1 GENERAL... 3 2.2 CONNECTIONS... 4 3 Operating Data... 5 3.1 ELECTRICAL OPERATING DATA... 5 3.2 OPERATING DATA - ELECTRICAL INTERFACE
More informationAGS Low profile capacitive air gap measuring sensor for rotating machines
Air gap sensor AGS Low profile capacitive air gap measuring sensor for rotating machines Low profile Air Gap Sensor for wind / hydro-generators and electrical motors High accuracy, non contact capacitive
More informationENCODERS FOR OIL & GAS
ENCODERS FOR OIL & GAS Explosive atmospheres demand extraordinary encoder solutions Even in the toughest environments Leine & Linde encoders have to be reliable and work perfectly. With a development process
More informationCoils for solenoid valves
MAKING MODERN LIVING POSSIBLE Technical leaflet Coils for solenoid valves www.danfoss.com B and A coils Encapsulated coils with long operating life, even under extreme conditions Standard coils for a.c.
More informationProduct Data Sheet 8506 VW-691
The engineer's choice 8506 VW-691 INDEX 1 General... 3 2 Mechanics... 3 2.1 GENERAL... 3 2.2 CONNECTIONS... 4 3 Operating Data... 5 3.1 ELECTRICAL OPERATING DATA... 5 3.2 OPERATING DATA - ELECTRICAL INTERFACE
More informationPart-Turn Electric Multi-Turn Electric
Optional 7 Handwheel Available NEMA 4 Enclosure Approvals MAR s Only (Canadian Standard Association) Enclosure NEMA 7 Enclosure Approvals MAR s Only (Canadian Standard Association) Class I, Divisions 1
More informationThe 2 way full range TKT102 is a 1,200 Watt 10" loudspeaker system. applications. Engineered for either permanent installation or portable
2 way full range loudspeaker for KTV applications Rotatable waveguide with 1 H x 6 V dispersion Watts continuous, 1,2 Watts peak power High power 1" low frequency driver with low mass voice coil Titanium
More informationIn-Ceiling Electric Motorized Front Projection Screen Evanesce Series. User s Guide
In-Ceiling Electric Motorized Front Projection Screen Evanesce Series User s Guide Important Safety & Warning Precautions Make sure to read this user s guide and follow the procedures below. Caution: The
More informationTECHNICAL MANUAL DRAW-WIRE DISPLACEMENT TRANSDUCER TYPE DWT
RDP Customer Document TECHNICAL MANUAL DRAW-WIRE DISPLACEMENT TRANSDUCER TYPE DWT Doc. Ref CD1004L BS EN ISO 9001 Certificate No. FM13141 Affirmed by Declaration of Conformity USA & Canada RDP Electrosense
More informationEXPlora. Introduction
Introduction EXPlora The EXPlora range is most suited to manufacturers of ancillary electrical equipment such as motors, pumps, lighting equipment, process and control gear for use in factories and plant
More informationOPERATING MANUAL FIXED FLOW PUMP DRIVES
OPERATING MANUAL FIXED FLOW PUMP DRIVES Model Nos. 7540-01 7540-30 7542-12 7540-02 7540-60 7542-20 7540-06 7542-01 7542-30 7540-12 7542-02 7542-60 7540-20 7542-06 Note: Drive is shown with optional Pump
More informationType: DILM25 10(24V50HZ) Article No.:
Type: DILM25 10(24V50HZ) Article No.: 277119 Ordering information Rated operational current AC 3 400 V I e A 25 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors,
More informationAnalog Input Module HART Ex n Inputs, 8 Channels Series 9461/15
> 8 channels for 2-wire HART transmitters > Inputs for Ex nl, Ex na and Nonincendive > Galvanic separation between inputs and system > Open-circuit and short-circuit monitoring for each field circuit >
More informationRoomMatch Utility RMU208 TECHNICAL DATA SHEET. small-format foreground/fill loudspeaker. Key Features. Technical Specifications
RoomMatch Utility RMU28 Key Features Award-winning RoomMatch sound now in smaller 2-way point-source designs for high-level foreground music, under-balcony, zone-fill and vocalrange floor monitor applications
More informationAF-300 E11 Adjustable Frequency Drive
AF-300 E11 Adjustable Frequency Drive The AF-300 E11 adjustable frequency drive is GE s new generation of micro drives. GE recognized your need for a high-performance, full-featured compact drive and designed
More informationType: DILM12 10(24VDC) Article No.:
Type: DILM12 10(24VDC) Article No.: 276845 Ordering information Rated operational current AC 3 400 V I e A 12 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors,
More informationType: NZMN1 A100 Article No.: Sales text Circuit breaker3p systems/cable prot. Ordering information Number of poles
Type: NZMN1 A100 Article No.: 259085 Sales text Circuit breaker3p systems/cable prot. Ordering information Number of poles Description Rated current = rated uninterrupted current Setting range 3 pole I
More informationDUCAT-IV Adjustable Aim Recessed LED Downlight
DUCAT-IV Adjustable Aim Recessed LED Downlight DUCAT-IV Adjustable Aim Recessed LED Downlight DUCAT-IV is an adjustable aim recessed downlight using 4 high power LEDs. Typical applications include general
More informationSPECIFICATION NO Model 207 Automatic GTAW Welding System
1.0 Introduction The Model 207 is a completely self-contained Gas Tungsten Arc Welding (GTAW) System requiring only input power, inert gas and AMI Welding Head (or manual torch) for operation. Its small
More informationVM GATE VALVE GRINDING & LAPPING MACHINE
VM1150-1200 GATE VALVE GRINDING & LAPPING MACHINE 2014 04 VM1150-1200 Lightweight for easy handling and installation. Powerful Wide working range: nominal diameter of 1.5-48 inches (40-1200 mm). Submersion
More informationTKT122. # Designed and engineered in the U.K. Precision and Detailed Clarity
2 way full range loudspeaker for KTV applications Low distortion waveguide with 7 H x 7 V dispersion 5 Watts continuous, 2, Watts peak power High power 12" low frequency driver with low mass voice coil
More informationAnalog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/
> 8 channels for 2-wire HART transmitters > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit monitoring for each field circuit > Module
More informationElectric Motorized Projection Screen PowerMax Tension Series
Electric Motorized Projection Screen PowerMax Tension Series User s Guide Important Safety & Warning Precautions Make sure to read this user s guide and follow the procedures below. Caution: The screen
More information2291 Guided Wave Radar Level Transmitter
2291 Guided Wave Radar Level Transmitter Product description / Function The 2291 Guided Wave Radar level transmitter is designed for continuous level measuring of conductive or non-conductive liquids,
More informationThe 2 way full range TKT122 is a 2,000 Watt 12" loudspeaker system. applications. Engineered for either permanent installation or portable
Product Information Document TKT122 2 way full range loudspeaker for KTV applications Low distortion waveguide with 7 H x 7 V dispersion 5 Watts continuous, 2, Watts peak power High power 12" low frequency
More informationProduct Data Sheet 4656 EZ
The engineer's choice 4656 EZ INDEX 1 General... 3 2 Mechanics... 3 2.1 GENERAL... 3 2.2 CONNECTIONS... 4 3 Operating Data... 5 3.1 ELECTRICAL OPERATING DATA... 5 3.2 OPERATING DATA - ELECTRICAL INTERFACE
More informationQuick-disconnect cables. Adjustable mounting brackets
MiniSafe File No. LR90200 Operation MiniSafe 1.0 inch (25.4 mm) resolution 100 foot (30.5 m) range Individual Beam Indicator lights covered by U.S. and international patents Compact size 2.25 x 1.8 inches
More informationSmall & Medium AC Accessories and Kits
Motor Bases, dapter These adapters permit mounting of new NEM frames so that shaft extension ends are positioned interchangeably with the old line NEM frames they replace. ll adapter mountings are supplied
More informationIncremental Rotary Encoders
Incremental Rotary Encoders Rotary Magnetic Incremental Encoder Encoders ELTRA are designed in order to control the position and the angular speed of moving mechanical axels. Rotary Incremental Eltra encoder
More informationWLC60 Heavy Duty LED Light - PWM Dimmable
WLC60 Heavy Duty LED Light - PWM Dimmable Datasheet Banner's WLC60 Heavy Duty Lights are engineered to withstand harsh environments, making it the first choice for a machine lighting solution. A conservative
More informationA wireless turntable for new way of enjoying vinyl records
Bluetooth Turntable TN-280BT 2-speed Analog Turntable with Phono EQ and Bluetooth A wireless turntable for new way of enjoying vinyl records Main Features 2-speed Belt-drive turntable Built-in MM phono
More informationVAT 20 Adjustable Frequency Drive
VAT 0 Adjustable Frequency Drive VAT 0 Adjustable Frequency Drive The VAT 0 is a small, flexible, low cost, well performing AC drive designed for use in small machines such as fans and conveyors. The drive
More informationLPUM - Local Power Unit General. Product Data Sheet January 2013 SD E06
LPUM - Local Power Unit General Product Data Sheet January 2013 SD 1520-0E06 TM LPUM - Local Power Unit January 2013 Description The LPUM - (Local Power Unit) - is an integrated electro-hydraulic system
More informationPhotoelectrics Through-beam Type PA18C.T..., DC
Photoelectrics Through-beam Type, DC Miniature sensor range Range: 20 m (Axial), 16 m (Radial) Sensitivity adjustment by potentiometer Modulated, infrared light 850 nm Supply voltage: to 30 VDC Output:
More informationDescription Set value in neutral conductor is synchronous with set value Ir of main pole. R.m.s. value measurement and thermal memory CSA 100
DATASHEET - NZMN3-4-AE400 Circuit-breaker, 4p, 400A Part no. NZMN3-4-AE400 Catalog No. 265891 Similar to illustration EL-Nummer (Norway) 0004358857 Delivery program Product range Circuit-breaker Protective
More informationIncremental Encoder DFS60 in a class of its own. The high-resolution incremental encoder range
ProduCt information Incremental Encoder DFS60 in a class of its own The high-resolution incremental encoder range PDF processed with CutePDF evaluation edition www.cutepdf.com DFS60 In a class of its own
More informationELECTRICAL. DATA AND INDEX Not all complements shown A shown for reference. Index A leads B, CW (from shaft end) TERMINAL CONNECTIONS COM VCC CASE
NorthStar brand SERIES HD35R Heavy Duty Encoder Key Features Phased Array Sensor for Reliable Signal Output Rugged Design with Wide-Spaced Oversized Bearings Unbreakable Code Disc up to 5000PPR Improved
More informationTENSIONED ELPRO CONCEPT Motorized projection screen for wall or ceiling installations
Motorized projection screen for wall or ceiling installations Watch the video: Product specifications: Electrically operated projection screen 230 volt (50Hz) with a usage of no more than 0.53 Ampere (121.9
More informationALLEN BRADLEY TIMING RELAY
ALLEN BRADLEY TIMING RELAY Configuration Details Product: 700-HS12BA1 Description: 700-HS General Purpose Square Base Timing Relay, On Delay Timer, 1.0 to 180 seconds, DPDT, 120V AC 50/60Hz CONTROL RELAY
More informationOperating temperatures from 20 C ( 4 F) up to 50 C (122 F). Up to 70 C (158 F) with current derating and optional control module fan kit.
PowerFlex 525 PowerFlex 525 AC drives feature an innovative, modular design offering fast and easy installation and configuration. These costeffective compact drives come with embedded EtherNet/IP communications,
More informationVM GATE VALVE GRINDING & LAPPING MACHINE
VM1350-1600 GATE VALVE GRINDING & LAPPING MACHINE 2014 04 VM1350-1600 Powerful, rigid design with easy set up and handling. Powerful Wide working range: nominal diameter of 1.5-48 inches (40-1200 mm).
More informationInstallation instructions Ex frames
General information Installation and maintenance: For European member countries of GENELEC shall standard EN 60079-14 and EN 60079-17 be considered. For countries members of IECEx shall standard IEC 60079-14
More informationVGA Extender over Cat 6 with Audio Support. Model Extend both video and audio up to 300 meters
VGA Extender over Cat 6 with Audio Support Model 103004 Extend both video and audio up to 300 meters Utilize a Cat 6 cable instead of a bulky VGA cable Supports a local monitor and local audio Easy installation
More informationLC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil
Product datasheet Characteristics LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationSplit System Air Conditioner
Residential & Light Commercial HVAC Split System Air Conditioner 1 R-410A, 1 2 thru 5 Tons 208/230 Volt, 1-Phase, 60 Hz Performance: Efficiency rating of 13 SEER Cooling capacities from 1 1 2 to 5 tons
More informationParts List _2.1. Flygt /.190
Parts List 886747_2. Flygt 3069 3069.60/.90 Table of Contents Table of Contents Introduction... 2. Specially approved products... 2 2 Product Description...3 2. The data plate...3 2.2 Approvals...4 2.3
More informationVGA Extender over Single CAT 6 Cable with Audio Support. Model Extend both video and audio up to 1000 feet
VGA Extender over Single CAT 6 Cable with Audio Support Model 103004 Extend both video and audio up to 1000 feet Utilize a Cat 6 cable instead of a bulky VGA cable Supports a local monitor and local speakers
More informationEmergency lighting units EM powerled
E 15 W CE CPS ED Driver for AC and DC power supplies Product description ED Driver for mains operation with integrated Simple CORRIDOR FUCTIO (CF) For use in central battery systems For luminaire installation
More informationMagnetic and Hydraulic-Magnetic Circuit Breaker
Magnetic and Hydraulic-Magnetic Circuit Breaker 850-... Description Single, two, three and four pole magnetic and hydraulic-magnetic circuit breakers with trip-free-mechanism and toggle or rocker actuation.
More informationLC3D115M7 TeSys D - star delta starter - 3 x 3P (3 NO) A V AC coil
Characteristics TeSys D - star delta starter - 3 x 3P (3 NO) - 115 A - 220 V AC coil Main Range Product name Product or component type Device short name Contactor application Utilisation category Device
More informationLC1D32P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A V AC 50/60 Hz coil
Characteristics TeSys D contactor - 3P(3 NO) - AC-3 -
More informationEXLUX ECOLUX C-LUX 6480 Series
EXLUX ECOLUX C-LUX 6480 Series 6000 6008 6400 6408 6600 6608 6500 6480 Explosion Protected Fluorescent Luminaires for Hazardous and Corrosive Applications Features: Electronic Ballasts For Fluorescent
More informationWLS27 Multicolor LED Strip Light with EZ-STATUS
WLS7 Multicolor LED Strip Light with EZ-STATUS Instruction Manual Banner's WLS7 Multicolor LED Strip Light has a sturdy aluminum housing and is encased in a shatterproof, UV-stabilized, copolyester shell,
More informationElectric Wall/Ceiling Projection Screen Saker Series User s Guide
Electric Wall/Ceiling Projection Screen Saker Series User s Guide Important Safety & Warning Precautions Make sure to read this user s guide and follow the procedures below. Caution: The screen s Black
More informationNessie Coils for VDH and VDHT valves
Data Sheet Nessie Coils for VDH and VDHT valves Introduction The coils for the Danfoss High-Pressure Systems valves are high-performance and reliable coils based on more than 50 years manufacturing of
More informationDatasheet. LED Transformers. LED Transformer 120W 24V V. LED Transformers
LED Transformers Datasheet LED Transformers LED Transformer 120W 24V 220-240V Product description Philips full-electronic constant voltage LED Transformers are designed to operate 24VDC LED solutions used
More informationSM-1100/SM-1500/SM-1600 ROTARY ACTUATORS
SM-1100/SM-1500/SM-1600 ROTARY ACTUATORS GENERAL DESCRIPTION The SM-1100, SM-1500 and SM-1600 Series are multi-turn, rotary actuators, designed to meet the exacting requirements for closed-loop modulating
More informationLC1D12P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A V AC coil
Characteristics TeSys D contactor - 3P(3 NO) - AC-3 -
More informationElectric Wall/Ceiling Projection Screen Saker Plus Series User s Guide
Electric Wall/Ceiling Projection Screen Saker Plus Series User s Guide Important Safety & Warning Precautions Make sure to read this user s guide and follow the procedures below. Caution: The screen s
More informationBulletin IND05 INDUSTRACON
Bulletin IND05 INDUSTRACON Models: IND-OT, IND-WT, IND-AH Industrial Exhauster Introduction CERTIFIED RATINGS Fans PennBarry certifies that the Series 61 Fans shown herein are licensed to bear the AMCA
More informationLC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil
Product datasheet Characteristics LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationLC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil
Product data sheet Characteristics LC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationOPERATING MANUAL. Cole-Parmer Stir-Pak. Mixer Head Model Numbers , , , , & Mixer Controller Model Numbers
OPERATING MANUAL Cole-Parmer Stir-Pak Mixer Head Model Numbers 50007-10, 50007-20, 50007-30, 50007-40, & Mixer Controller Model Numbers 50007-00 Cole-Parmer ServoDyne Mixer Head Model Numbers 50008-10,
More informationFOREST SHUTTLE S / L / M RECEIVER
2 FOREST SHUTTLE S / L / M RECEIVER QUICK INSTALLATION OF ASSEMBLED TRACKS : Programming Shuttle S / L / M Receiver to a channel One pre-assembled motorized curtain track systems is standard programmed
More informationSeries CT7N Bimetallic Overload Relays
Series CT7N imetallic Overload Relays Choose CT7N overloads in DC applications and when monitoring Variable Frequency Drives Sprecher + Schuh has always paid particular attention to the subject of motor
More informationCENTRAL BLOWER COMPANY 211 S. 7th Ave. City of Industry, CA (626) Fax (626)
CENTRAL BLOWER COMPANY 211 S. 7th Ave. City of Industry, CA 91746 (626) 330-3182 Fax (626) 330-9406 www.centralblower.com CATALOG REF-11 OCTOBER 2011 Series RE Scoop with Grease Trough Sealed to blower
More informationLED MODULES READYLINE DL
LED MODULES READYLINE DL BUILT-IN MODULE LED-MODULE READYLINE DOWNLIGHT DL WU-M-538 / WU-M-539 / WU-M-540 Typical Applications Downlights Replacement for CFL DIRECT MAINS CONNECTION REDUCED FLICKER HIGH
More informationLC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil
Product data sheet Characteristics LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationllen-bradley 194R-HM4-NFPA3
Technical Data Rotary Disconnect Switch Specifications Bulletin Number 194R Topic Page Product Line Overview 2 General Specifications Fuse Description 12 Approximate Dimensions 14 Additional Resources
More informationPushbutton Units and Indicator Lights
Insert labels and insert caps Clear, illuminated and indicator lights can be fitted with insert labels and caps for identification purposes. These labels and caps are made of a semi-transparent molded
More informationAC1036. Definite Purpose Contactors
Definite Purpose Contactors Definite purpose contactors Definite purpose Contactors Applications Type DP contactors provide high performance with flexibility and reliability, designed to match numerous
More information