Small & Medium AC Accessories and Kits

Size: px
Start display at page:

Download "Small & Medium AC Accessories and Kits"

Transcription

1 Motor Bases, dapter These adapters permit mounting of new NEM frames so that shaft extension ends are positioned interchangeably with the old line NEM frames they replace. ll adapter mountings are supplied as individually packaged kits with complete instructions. Frame Ordering Number Notes ist Price Price Symbol pprox. Wt. (lb) Norm. Stocked T $69 RSE56 3 Yes T RSE56 3 Yes T RSE56 3 Yes T RSE56 3 Yes 254U-213T B 130 RSE56 6 Yes 256U-215T B 130 RSE56 6 Yes 284U-254T C 130 RSE56 7 Yes 286U-256T C 130 RSE56 7 Yes 324U-284T D 167 RSE56 11 Yes 326U-286T D 167 RSE56 10 Yes 326U-284TS RSE56 10 Yes 364U-324TS E 286 RSE56 14 Yes 365U-326T E 286 RSE56 15 Yes 404U-364T P 294 RSE56 20 Yes 404US-364TS R 340 RSE56 21 Yes 405U-365T P 294 RSE56 21 Yes 404US-364TS R 340 RSE56 21 Yes 444U-364T S 451 RSE56 95 N 445U-365T S 451 RSE56 95 N For additional product information, go to Synchronous - Permanent Synchronous - Reluctance Kiln Duty Submersible ccessories & Kits Modifications M-141

2 Submersible Kiln Duty Synchronous - Reluctance Synchronous - Permanent Motor Bases, Sliding Bases for use with C Motors - T-Frame and U-Frame Frame Ordering Number Notes ist Price Price Symbol pprox. Wt. (lb) Norm. Stocked F $40 RSE56 5 Yes 143T RSE56 6 Yes 145T B 69 RSE56 6 Yes 182T, U U 85 RSE56 9 Yes 184T, U V 85 RSE56 10 Yes 213T, U W 95 RSE56 15 Yes 215T, U X 95 RSE56 16 Yes 254T, U 256T, U 284T, U 286T, U 324T, U 326T U 364T, U 365T, U 404T, U 405T, U 444T, U 445T, U D 140 RSE56 18 Yes E RSE56 20 Yes Y 140 RSE56 22 Yes P RSE56 22 Yes E 167 RSE56 27 Yes M RSE56 27 Yes Z 167 RSE56 22 Yes T RSE56 25 Yes F 229 RSE56 37 Yes R RSE56 40 Yes RSE56 32 Yes D RSE56 37 Yes H 297 RSE56 49 Yes U RSE56 49 Yes J 297 RSE56 45 Yes V RSE56 49 Yes K 599 RSE56 60 Yes F RSE56 55 Yes RSE56 61 Yes RSE56 65 Yes M 665 RSE56 83 Yes H RSE56 74 Yes N 665 RSE56 85 Yes J 21, RSE56 75 Yes 447/9T R 23 2,700 RSE Yes ccessories & Kits Modifications For pricing information or to place orders, go to M-142

3 Double C-Face Motor Brakes DBSS Model COMPETE UNIT PRT NUMBER - DISCOUNT CB20 NOTES: DOUBE C-FCE Standard Enclosure Unit Size --- Static Torque 3 Ft- bs 6 Ft- bs 10 Ft - bs 15 Ft- bs 20 Ft- bs 25 Ft- bs DBSS Complete Units 56 Frame, 5/8, Bore $578 $622 $702 $808 $1,078 $1, /230 VC 60 Hz (1) /460 VC 60 HZ (2) /575 VC 60 Hz (3) /208 VC 60 Hz (4) /380 VC 50 Hz (5) /500 VC 50 Hz DBSS Complete Units 140 Frame, 7/8Ó, Bore 115/230 VC 60 Hz (1) /460 VC 60 HZ (2) /575 VC 60 Hz (3) /208 VC 60 Hz (4) /380 VC 50 Hz (5) /500 VC 50 Hz Bold Part Numbers are stock units. Other voltage units available on standard non-stock basis. Coil will operate at the following voltages: (1) 15/ VC 50 or 60 Hz,133/265 VC 60 Hz, VDC (3) 287/575 VC 60 Hz, 300/600 VC 60 Hz (2) /460 VC 50 or 60 Hz, 240/480 VC 60 Hz, 220/440 VC 50 Hz, 230 VDC (4) 104/208 VC 50 or 60 Hz, 100/200 VC 60 Hz, VDC DIMENSIONS Standard Enclosure Double C-face Coupler Unit Size 56DBSS-3 56DBSS-6 56DBSS-10 56DBSS-15 56DBSS-20 56DBSS DBSS-3 140DBSS-6 140DBSS DBSS DBSS DBSS-25 Inertia Friction Disc & Hub (b.on2) Input Bore Shaft Keyway & Input Keyway Max 1 Nom K "C" (4) MOUNTIN BOTS (5) 190/380 VC 50 Hz, 200/400 VC 60 Hz, 206/416 VC 50 Hz H For additional product information, go to SHFT H (3) IRP DJUSTMENT SCREWS 1/4-28 x 2-3/4 J 1 "B" DIMETER BORE 3/4, NPT THREDED HOE FOR OPTION CONDUIT FITTIN B Max. B1 Radius Max. K C Mounting Bolts KEY "B1" RDIUS (5) ED WIRES (PPROX. 10, ON) J (2) 1/4-20 UNC SET SCREWS PRT (PIOT PTE NOT SHOWN) /8 3/16 x 3/ /8/16 UNC-2 (4) Equally Spaced on Bolt Circle /8 3/16 x 3/ Shipping Weight bs) Synchronous - Permanent Synchronous - Reluctance Kiln Duty Submersible ccessories & Kits Modifications M-143

4 Synchronous - Permanent Double C-Face Motor Brakes "C" (4) MOUNTIN BOTS H 1 "-B1" RDIUS K SHFT BORE J KEY ccessories & Kits Submersible Kiln Duty Synchronous - Reluctance DBES Model COMPETE UNIT PRT NUMBERS - DISCOUNT CB20 NOTE: DOUBE C-FCE (3) IRP DJUSTMENT SCREWS 1/4-28 x 2-3/4 3/4, NPT THREDED HOE FOR OPTION CONDUIT FITTIN (5) ED WIRES (PPROX. 10, ON) E-Z KEEN Enclosure Unit Size-Static Torque 3 Ft- bs 6 Ft- bs 10 Ft- bs 15 Ft- bs 20 Ft- bs 25 Ft- bs DBES Complete Units 56 Frame, 5/8, Bore $900 $1,078 $1,188 $1,302 $1,442 $1, /230 VC 60 Hz (1) /460 VC 60 HZ (2) /575 VC 60 Hz (3) DBES Complete Units 140 Frame, 7/8, Bore 115/230 VC 60 Hz (1) /460 VC 60 HZ (2) /575 VC 60 Hz (3) ll torque ratings and voltages not listed here are available as standard non-stock units. Please contact DODE Customer Service for part numbers, pricing & availability. Coil will operate at the following voltages: (1) 115/ VC 50 or 60 Hz,133/265 VC 60 Hz, VDC (2) /460 VC 50 or 60 Hz, 240/480 VC 60 Hz, 220/440 VC 50 Hz, 230 VDC (3) 287/575 VC 60 Hz, 275/550 VC 60 Hz, 300/600 VC 60 Hz DIMENSIONS E-Z KEEN Double C-Face Coupler Unit Size 56DBES-3 56DBES-6 56DBES-10 56DBES-15 56DBES-20 56DBES DBES-3 140DBES-6 140DBES DBES DBES DBES-25 Inertia Friction Disc & Hub (b.-in2) Input Bore & Shaft. Keyway & Input Key Nom 1 Nom K.. H J B Max. B1 Radius Max C Mounting Bolts /8 3/16 x 3/ /8/16 UNC-2 (4) Equally Spaced on Bolt Circle /8 3/16 x 3/ Shipping Weight (bs) Modifications For pricing information or to place orders, go to M-144

5 Kits C-Face Kit (48-140Frames) Frame Enclosure Ordering Number Notes ist Price Price Symbol pprox. Wt. (lb) Norm. Stock 56 * Basic (TEFC, TENV) K56H $36 RSM01 2 Yes 56, 140 ** Basic (TEFC, TENV) K56H RSM01 3 Yes (1) Basic (TEFC, TENV) motors that have aluminum end shields. This kit will not mount on XT/EMT/XEX and other enhanced enclosure product that have Cast Iron end shields * For frames beginning with E ; ie, EB56 ** For frames beginning with F ;ie, FB56 C-Face Kit (180T - 400T Frames) Frame Enclosure Ordering Number Notes ist Price Price Symbol pprox. Wt. (lb) Norm. Stock 180T TEFC, TEFC-EMT, TEFC-XEX K183 3,12 $125 RSE56 5 Yes TEFC K1832 c RSE56 5 Yes ODP K18S33 b RSE56 3 Yes TEFC K18S34 a RSE56 3 Yes 180 TEFC U-FRME K185 3, RSE56 10 Yes 210T, U 250T, U 280T, U TEFC, TEFC-EMT, TEFC-XEX K213 3, RSE56 18 Yes TEFC K2132 c RSE56 10 Yes ODP K21S33 b* RSE56 7 Yes ODP K21S35 a** RSE56 7 Yes TEFC K21S34 a RSE56 7 Yes TEFC, TEFC-EMT, TEFC-XEX K252 3, RSE56 25 Yes TEFC K2532 c RSE56 18 Yes ODP K25S33 b RSE56 15 Yes TEFC K25S34 a RSE56 15 Yes TEFC, TEFC-EMT, TEFC-XEX K282 3, RSE56 32 Yes 320T, U TEFC, TEFC-EMT, TEFC-XEX 360T, U TEFC, TEFC-EMT, TEFC-XEX TEFC K2832 c RSE56 25 Yes ODP K28S33 b RSE56 22 Yes TEFC K28S34 a RSE56 22 Yes K322 3, RSE56 34 Yes K3232 c RSE56 57 Yes K362 3, RSE56 40 Yes K3632 c* RSE56 40 Yes K3635 c** RSE56 40 Yes 400T, U TEFC, TEFC-EMT, TEFC-XEX K402 3, RSE56 46 Yes * 1200 RPM ** 3600 RPM Note: Kits with suffix a, b, or c can only be used on motor models with the corresponding suffix. C-face kits with a suffix when added to a motor will not meet NEM B dimension. D-Flange Kit Frame Enclosure Ordering Number Notes ist Price Price Symbol pprox. Wt. (lb) Norm. Stock 180, 180T TEFC, TEFC-EMT, TEFC-XEX K186 3,47 $226 RSE56 10 N 210, 210T TEFC, TEFC-EMT, TEFC-XEX K216 3, RSE56 15 N Conduit Box Kit Frame Motor Enclosure Conduit Box Material Ordering Number Notes ist Price Price Symbol For additional product information, go to pprox. Wt. (lb.) 48, 56 XP luminum K48H $47 RSM01 1 Yes T Norm. Stock XP luminum K RSM01 1 Yes XP-XT Cast Iron K56H RSM01 1 Yes ODP/TENV Steel K56H RSM01 1 Yes 180T TEFC Cast Iron K RSE56 3 Yes 210T TEFC Cast Iron K RSE56 3 Yes 250T TEFC Cast Iron K RSE56 6 Yes 280T TEFC Cast Iron K RSE56 10 Yes 320T TEFC Cast Iron K RSE56 15 Yes 360T TEFC Cast Iron K RSE56 20 Yes Synchronous - Permanent Synchronous - Reluctance Kiln Duty Submersible ccessories & Kits Modifications M-145

6 Synchronous - Permanent Synchronous - Reluctance Kits Drip Cover / Canopy Kit Frame Enclosure Ordering Number Notes ist Price Price Symbol pprox. Wt. (lb) Norm. Stock 56, 140T TEFC, XT, XP K56H $51 RSM01 1 Yes 180T 210T TEFC, TEFC-EMT, TEFC-XEX K RSE56 12 Yes TEFC K1819 c 82 RSE56 8 Yes TEFC K18S30 a 82 RSE56 6 Yes TEFC, TEFC-EMT, TEFC-XEX K RSE56 18 Yes TEFC K2119 c 103 RSE56 10 Yes TEFC K21S30 a 103 RSE56 8 Yes 250T TEFC K25S30 a 154 RSE56 12 Yes 280T TEFC K28S30 a 215 RSE56 18 Yes Note: Kits with suffix a, b, or c can only be used on motor models with the corresponding suffix. Kiln Duty Mill and Chemical Duty Kit Cast Iron Shroud and Conduit Box Frame Enclosure Ordering Number Notes ist Price Price Symbol pprox. Wt. (lb) Norm. Stock 180T TEFC K1818 c $149 RSE56 12 Yes 210T TEFC K2118 c 205 RSE56 15 Yes 250T TEFC K2518 c 277 RSE56 20 Yes 280T TEFC K2818 c 328 RSE56 25 Yes 320T TEFC K3218 c 359 RSE56 30 Yes 360T TEFC K3618 c 580 RSE56 Note: Kits with suffix a, b, or c can only be used on motor models with the corresponding suffix. Brake Fast Response Kit - D Series Brake Frame Enclosure Ordering Number Notes ist Price Price Symbol pprox. Wt. (lb) Norm. Stock 56, 140, 180 ll /460 $120 CB20 1 Yes 56, 140, 180 ll / CB20 1 Yes Submersible ccessories & Kits Brake Rectifier Kit - Replacement Kit Frame Enclosure Ordering Number Notes ist Price Price Symbol pprox. Wt. (lb) Norm. Stock 56, 140, 180 ll For both DBSC & DBSS $76 CB20 1 Yes uxiliary Conduit Box Kits Frames Enclosure Ordering Number Notes ist Price Price Symbol pprox. Wt. (lb) Norm. Stock 180/210 TEFC-XEX K1821 $55 RSE56 4 Yes 250 TEFC-XEX K RSE56 9 Yes 280 TEFC-XEX K RSE56 9 Yes 320 TEFC-XEX K RSE56 9 Yes 360 TEFC-XEX K RSE56 12 Yes 400 TEFC-XEX K RSE56 15 Yes 440 TEFC-XEX K RSE56 18 Yes Modifications For pricing information or to place orders, go to M-146

UNIBRAKE AC Motor Brakes

UNIBRAKE AC Motor Brakes A L T R A I N D U S T R I A L M O T I O N UNIBRAKE AC Motor UNIBRAKE Decelerates or Holds Loads When Power is Off Page 4-9 C-Face, Power-Off Single C-Face Power-Off are designed to decelerate or hold inertia

More information

A L T R A I N D U S T R I A L M O T I O N. UNIBRAKE AC Motor Brakes

A L T R A I N D U S T R I A L M O T I O N. UNIBRAKE AC Motor Brakes A L T R A I N D U S T R I A L M O T I O N UNIBRAKE AC Motor Brakes UNIBRAKE decelerates or holds loads when power is off Page 4-9 Page 10-13 Page 14-17 C-Face, Power-Off Brakes Single C-Face Power-Off

More information

70 Series End Mount 8700 Style NEMA Frame Sizes 182TC through 256TC/UC Torque Ratings: 10 to 105 lb-ft

70 Series End Mount 8700 Style NEMA Frame Sizes 182TC through 256TC/UC Torque Ratings: 10 to 105 lb-ft 70 Series End Mount 8700 Style EMA Frame Sizes 182 through 256/U Ratings: 10 to 105 Dripproof EMA 2, SA 2, IP43 70 Series Specifications: Reaction ime: 20-25 milliseconds (release and set) AK: 8.5 Register

More information

Product Information Packet EM2334T 20HP,1770RPM,3PH,60HZ,256T,0960M,TEFC,F1

Product Information Packet EM2334T 20HP,1770RPM,3PH,60HZ,256T,0960M,TEFC,F1 Product Information Packet EM2334T 20HP,1770RPM,3PH,60HZ,256T,0960M,TEFC,F1 Copyright ll product information within this document is subject to Motors and Mechanical Inc. copyright protection, unless otherwise

More information

W.C. BRANHAM INC. Right Angle Gear Drives

W.C. BRANHAM INC. Right Angle Gear Drives S O L U T I O N S I N M O T I O N Right Angle Gear Drives RIGHT ANGLE GEAR DRIVES APPLICATION USES Providing solutions to your gear drive needs Check Weighing Systems Web tensioning machinery Packaging

More information

Magnetic Drive Pumps. 180 Hines Ave. Bellville, OH PH: FAX:

Magnetic Drive Pumps. 180 Hines Ave. Bellville, OH PH: FAX: Operation is similar to standard centrifugal pumps, except the impeller is driven with a magnetic coupling, eliminating the need for a shaft seal. Magnetic drive pumps must be used where flooded suction

More information

Bulletin IND05 INDUSTRACON

Bulletin IND05 INDUSTRACON Bulletin IND05 INDUSTRACON Models: IND-OT, IND-WT, IND-AH Industrial Exhauster Introduction CERTIFIED RATINGS Fans PennBarry certifies that the Series 61 Fans shown herein are licensed to bear the AMCA

More information

Absolute Rotary Encoder E6CP

Absolute Rotary Encoder E6CP Absolute Rotary Encoder Absolute Rotary Encoders with Gray Code Output Gray code output decreases output errors Lightweight plastic housing Used with Omron s H8PS Cam Positioner, this encoder detects the

More information

NEMA JM/JP Close Coupled Pump Motors. Features Include: NEMA MG1-Part 31 inverter duty 15:1 constant torque, 20:1 variable torque.

NEMA JM/JP Close Coupled Pump Motors. Features Include: NEMA MG1-Part 31 inverter duty 15:1 constant torque, 20:1 variable torque. W Series JM/JP - TEFC Cast 143-286, 324-365 JM/JP Pump Motors. Features Include: MG1-Part 31 inverter duty 15:1 constant torque, 20:1 variable torque 1 HP to 30 HP 40 HP to 75 HP 1.25 service factor at

More information

Fluid Cooling P-BAR b Industrial BOL Series

Fluid Cooling P-BAR b Industrial BOL Series Fluid Cooling P-BAR b Industrial BOL Series 10 BRAZED ALUMINUM CONSTRUCTION Performance Notes Bar and plate brazed aluminum core Provides the best heat transfer per given envelope size while minimizing

More information

2100, 2200, 4100, 6200, MPB Series Side Mount Drive Package for Light Load 60 Hz Gearmotors

2100, 2200, 4100, 6200, MPB Series Side Mount Drive Package for Light Load 60 Hz Gearmotors 00, 00, 400, 600, MPB Series Side Mount Drive Package for Light Load 60 Hz Gearmotors Installation, Maintenance & Parts Manual DORNER MFG. CORP. INSIDE THE USA OUTSIDE THE USA P.O. Box 0 975 Cottonwood

More information

.152 (3.86) KEYWAY DEPTH .033 (.84).066 (1.68) .550 DIA (13.97) MOUNTING SURFACE .350 (8.89) 3/8-32 UNEF-2A THREADS (19.71.

.152 (3.86) KEYWAY DEPTH .033 (.84).066 (1.68) .550 DIA (13.97) MOUNTING SURFACE .350 (8.89) 3/8-32 UNEF-2A THREADS (19.71. Optical SERIES 61K High Resolution, 4-Pin FEATURES 25, 32, 50, 64, 100, 128 and 256 Cycles per Revolution Available Sealed Version Available Rugged Construction Cable or Pin Versions 10 Million Rotational

More information

SQM40/41 Actuators for air and gas dampers

SQM40/41 Actuators for air and gas dampers SQM40/41 Actuators for air and gas dampers Description SQM40/41 actuators are used for the positioning of flow control valves, butterfly valves, dampers or any application requiring rotary motion. The

More information

EZ Encoder : Optical Incremental

EZ Encoder : Optical Incremental 1. Introduction The EZ25 Encoder is a 2.5 incremental optical encoder, designed for optical shaft encoder motion control and precision sensor systems. Our ET7272 available models are short circuit proof

More information

Smart-Encoder : Optical Incremental

Smart-Encoder : Optical Incremental 1. Introduction The Smart-Encoder effectively eliminates multiple encoder part numbers by bringing intelligence and security to its design. In seconds, a four-digit LED display with two push-buttons enables

More information

Close Coupled Motor. Hydraulics. Catalog /USA. Hydraulics. Close Coupled Motor B81. Catalog HY /US

Close Coupled Motor. Hydraulics. Catalog /USA. Hydraulics. Close Coupled Motor B81. Catalog HY /US Close Coupled Catalog 2600-510-02/US 81 Performance Information The Parker close coupled electric motor/pump provides exceptional performance and compact size at an economical price. lso, with the elimination

More information

High Head Close-Coupled Centrifugal Pumps

High Head Close-Coupled Centrifugal Pumps Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect

More information

Material: Weight: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

Material: Weight: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands: Oil & Gas / Heavy Industry Type 2REX-H EN 60079 Electrical Specifications Code: Resolution: Supply Voltage: Voltage: Current: Incremental 1 to 10,000 ppr (pulses per revolution) 4.5 Vdc min. to 30 Vdc

More information

Part-Turn Electric Multi-Turn Electric

Part-Turn Electric Multi-Turn Electric Optional 7 Handwheel Available NEMA 4 Enclosure Approvals MAR s Only (Canadian Standard Association) Enclosure NEMA 7 Enclosure Approvals MAR s Only (Canadian Standard Association) Class I, Divisions 1

More information

Material: Weight: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

Material: Weight: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands: Oil & Gas / Heavy Industry Type 2REX-H-SR EN 60079 Electrical Specifications Code: Resolution: Supply Voltage: Voltage: Current: Incremental 1 to 10,000 ppr (pulses per revolution) 4.5 Vdc min. to 30 Vdc

More information

2100/2200/4100/6200 & MPB Series Bottom Mount Drive Pack. for Standard Load Parallel Shaft 60 Hz Gearmotors

2100/2200/4100/6200 & MPB Series Bottom Mount Drive Pack. for Standard Load Parallel Shaft 60 Hz Gearmotors 00/00/400/600 & MPB Series Bottom Mount Drive Pack. for Standard Load Parallel Shaft 60 Hz Gearmotors Installation, Maintenance & Parts Manual DORNER MFG. CORP. INSIDE THE USA OUTSIDE THE USA P.O. Box

More information

EZ Encoder : Optical Incremental (P Series)

EZ Encoder : Optical Incremental (P Series) 1. Introduction Our EZ Encoders effectively eliminate multiple encoder part numbers by bringing intelligence and security to the design. A four-digit LED display with two push-buttons enables the user

More information

Accessories. Servo Motors. Servo Motors B-47. Accessories

Accessories. Servo Motors. Servo Motors B-47. Accessories Servo Motors Servo Motors Accessories Accessories Page Cables B-48 Flexible Couplings B-52 Control Module B-55 Data Setting Software B-55 Accessory Sets B-56 Battery B-56 Regeneration Units B-57 B-47 Accessories

More information

ENC-MC58SN-L R-L1

ENC-MC58SN-L R-L1 MC58/ MC59/ MC60 Hollow Shaft Magnetic Encoder Series FETURES DESCRIPTION Standard Encoder for Heavy Industrial pplications Hollow Shaft up to ø15mm 20 to 10,000 Cycles Per Revolution 80 to 40,000 Pulses

More information

Air Moving Solutions. axifan TUBEaxial fans

Air Moving Solutions. axifan TUBEaxial fans Air Moving Solutions. axifan TUBEaxial fans MODEL TCTA CATALOG AX200 January 2013 TubeaxialFans Model TCTA 36 B 5 Model TCTA is available with UL/ CUL 705 listing for electrical, File No. E158680. Model

More information

XML LED X M L L E D. Explosionproof Linear LED Lighting

XML LED X M L L E D. Explosionproof Linear LED Lighting LED Class I, Division 1, Groups C & D Class I, Division 2, Groups C & D Class II, Division 1, Groups E, F & G Class III Simultaneous Presence UL 844 Hazardous Locations IEC Ex d Zone 1 Equivalent UL 924

More information

DC Motors & Controls. DC2 DC Drives for 1/4 thru 2 Hp PMDC and Shunt Wound Motors. 1/4-2 Hp 115/230 VAC 1 Phase 50/60 Hz.

DC Motors & Controls. DC2 DC Drives for 1/4 thru 2 Hp PMDC and Shunt Wound Motors. 1/4-2 Hp 115/230 VAC 1 Phase 50/60 Hz. HVAC Farm Duty Brake 200 & 575 Volt & Controls DC 310 DC2 DC Drives for 1/4 thru 2 Hp PMDC and Shunt Wound DC & Controls 1/4-2 Hp 115/ 1 Phase 50/60 Hz. Applications: General purpose industrial use with

More information

ELECTRICAL. DATA AND INDEX Not all complements shown A shown for reference. Index A leads B, CW (from shaft end) TERMINAL CONNECTIONS COM VCC CASE

ELECTRICAL. DATA AND INDEX Not all complements shown A shown for reference. Index A leads B, CW (from shaft end) TERMINAL CONNECTIONS COM VCC CASE NorthStar brand SERIES HD35R Heavy Duty Encoder Key Features Phased Array Sensor for Reliable Signal Output Rugged Design with Wide-Spaced Oversized Bearings Unbreakable Code Disc up to 5000PPR Improved

More information

Small and Medium Industrial Motors

Small and Medium Industrial Motors Small and Medium Industrial Motors PRODUCT ABBREVIATIONS XT = Extra Tough EM = E-Master (EPAct compliant) EMT = E-Master, Extra Tough XE = Premium Efficient NEMA PREMIUM/CEE The Consortium for Energy Efficiency

More information

SM-1100/SM-1500/SM-1600 ROTARY ACTUATORS

SM-1100/SM-1500/SM-1600 ROTARY ACTUATORS SM-1100/SM-1500/SM-1600 ROTARY ACTUATORS GENERAL DESCRIPTION The SM-1100, SM-1500 and SM-1600 Series are multi-turn, rotary actuators, designed to meet the exacting requirements for closed-loop modulating

More information

and Refrigeration Institute). Hydraulic Elevator Wye-Delta Contactors

and Refrigeration Institute). Hydraulic Elevator Wye-Delta Contactors C7 Series C7 Special Use designed and labeled for specific industrial applications The C7 line includes a number of contactors designed and labeled for specific industrial applications. In most cases,

More information

TEK-LCD 7801A. NEMA 4X Loop-Powered Feet and Inches Level Meter. ACCESSORIES. Technology Solutions

TEK-LCD 7801A. NEMA 4X Loop-Powered Feet and Inches Level Meter.   ACCESSORIES. Technology Solutions Technology Solutions TEK-LCD 7801A NEMA 4X Loop-Powered Feet and Inches Level Meter ACCESSORIES www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction The

More information

FLUID COOLING Industrial BOL Series

FLUID COOLING Industrial BOL Series FLUID COOLING Idustrial Series AIR COOLED brazed alumium Costructio Features bar ad Plate Brazed Alumium Core rugged, lightweight, ad compact provides the best heat trasfer per give evelope size while

More information

DATA AND INDEX Not all complements shown A shown for reference. Index A leads B, CW (from clamp end)

DATA AND INDEX Not all complements shown A shown for reference. Index A leads B, CW (from clamp end) NorthStar brand HAZARDOUS SERIES HSD35 Key Features UL Certified for Hazardous Applications Rugged Design Resists up to 400g Shock and 20g Vibration Compact Design with Field Serviceable Connector for

More information

Contactors. Agency approvals. UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B

Contactors. Agency approvals. UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B Contactors Applications Type DP provide high performance with flexibility and reliability, designed to match numerous applications including: Motors Power supplies Food service equipment Compressors Business

More information

Movable Contacts Heavy duty silver cadmium oxide composition to resist welding and contact erosion for greater reliability

Movable Contacts Heavy duty silver cadmium oxide composition to resist welding and contact erosion for greater reliability Compare These Features Built-in Shock bsorber Reduces contact bounce for longer life. Coil Dust Cover Keeps dust and dirt away from magnet and coil area. Coil Class B (1300 C Insulation System) with wide

More information

Okta 600, Roots pump, 230/400 V, 50 Hz; 265/460 V, 60 Hz

Okta 600, Roots pump, 230/400 V, 50 Hz; 265/460 V, 60 Hz Okta 600, Roots pump, 230/400 V, 50 Hz; 265/460 V, 60 Hz Okta 600, Roots pump, 230/400 V, 50 Hz; 265/460 V, 60 Hz Similar Image Dimensions Technical Data Ambient temperature 5-40 C Cooling method, standard

More information

Series CDP2 Definite Purpose Contactors

Series CDP2 Definite Purpose Contactors Series 2 Definite Purpose High performance economical contactors for commercial applications up to 90 Sprecher + Schuh s Definite Purpose contactors are ideal for commercial applications including air

More information

DOWNDRAFT SANDING TABLES

DOWNDRAFT SANDING TABLES 888-377-2454 276-656-1039 fax DOWNDRAFT SANDING TABLES DUSKITS offers a comprehensive line of downdraft sanding tables for industry, and table kits for smaller shops and individual craftsmen All of our

More information

VM GATE VALVE GRINDING & LAPPING MACHINE

VM GATE VALVE GRINDING & LAPPING MACHINE VM1150-1200 GATE VALVE GRINDING & LAPPING MACHINE 2014 04 VM1150-1200 Lightweight for easy handling and installation. Powerful Wide working range: nominal diameter of 1.5-48 inches (40-1200 mm). Submersion

More information

Modular Lube Lubrication Systems System Controls

Modular Lube Lubrication Systems System Controls Model 84501 Program Timer Solid State Designed to control the lubrication cycle frequency of air-operated single-stroke pumps. Timer turns pump on/off at programmed intervals via a 3-way or 4-way air solenoid

More information

Agency approvals UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B

Agency approvals UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B 11 Applications Type DP provide high performance with flexibility and reliability, designed to match numerous applications including: Motors Power supplies Food service equipment Compressors Business machines

More information

MVSI-TS. Technical features

MVSI-TS. Technical features Technical features Power supply Three-phase voltage from 48V to 690V, 50Hz or 60Hz; suitable for use with an inverter from 20Hz to the base frequency, with constant torque load profile. Polarity 4, 6 and

More information

lumenalpha spot Specification Sheet

lumenalpha spot Specification Sheet Client Project name Order# Type Qty FEATURES AND BENEFITS Physical Housing material: extruded aluminum Available in or 8 sections Finish: black or white Ceiling mounting: surface or recessed Wall mounting:

More information

ENC-CK58SN-L R-L1

ENC-CK58SN-L R-L1 CK58/ CK59/ CK60 Blind Hollow Shaft Encoder Series FETURES Standard Encoder for Heavy Industrial pplications Blind Hollow Shaft up to ø15mm 2 to 10,000 Cycles Per Revolution 8 to 40,000 Pulses Per Revolution

More information

VM GATE VALVE GRINDING & LAPPING MACHINE

VM GATE VALVE GRINDING & LAPPING MACHINE VM1350-1600 GATE VALVE GRINDING & LAPPING MACHINE 2014 04 VM1350-1600 Powerful, rigid design with easy set up and handling. Powerful Wide working range: nominal diameter of 1.5-48 inches (40-1200 mm).

More information

and Refrigeration Institute). CAQ7 Capacitor Switching Contactors

and Refrigeration Institute). CAQ7 Capacitor Switching Contactors SSN9000 Series C7 Special Use designed and labeled for specific industrial applications Special Use Capacitor switching contactors HVC rated contactors NEM size labeled contactors Lighting contactors Hydraulic

More information

ENCODER. Incremental Angle Transducer. Series A36, A58. Key-Features:

ENCODER. Incremental Angle Transducer. Series A36, A58. Key-Features: ENCODER Incremental Angle Transducer Series A36, A58 Key-Features: Content: Technical Data A36...2 Technical Data A58...4 Elektrical Data...6 Accessories...7 Measuring Wheels...8 Order Code...9 - Incremental

More information

TECHNICAL DATASHEET Absolute Encoder AC 58 - SSI-P

TECHNICAL DATASHEET Absolute Encoder AC 58 - SSI-P n n n n n Compact design: 59 mm mounting depth for single or multiturn Aids for start up and operation: diagnostic LED, preset key with optical response Parameterization: Resolution, code type, direction,

More information

ARS 20, ARS 25: Single-turn Absolute Encoders. Modular Design for tailor-made solutions.

ARS 20, ARS 25: Single-turn Absolute Encoders. Modular Design for tailor-made solutions. , : ingle-turn bsolute Encoders. Modular Design for tailor-made solutions. Maximum reliability as a result of opto-ics with Chip-on-Board technology quare flange, servo and face mount options with 1/4,

More information

Surge Protective Device

Surge Protective Device Surge Protective Device Series RE - Residential TYPE Whole house surge protection Blue indicator LED 50 ka surge current strength Optional electrical noise filter Five year warranty Protect residence from

More information

WFH SERIES Fluorescent High-Bay Lighting for Hazardous Locations

WFH SERIES Fluorescent High-Bay Lighting for Hazardous Locations WFH SERIES W FH Fluorescent High-Bay Lighting for Hazardous Locations Class I, Division 2, Groups A, B, C, & D Class II, Division 2, Groups F & G Class III UL Listed for Wet & Hazardous Locations CUL Listed

More information

GENESIS Indoor Air Conditioners

GENESIS Indoor Air Conditioners Product Overview : Indoor Air Conditioners M28 Model M52 460 Volt 3-Phase Model M17 Model 68 68 Product Overview : The specifier s choice for cooling industrial process controls Indoor Air Conditioners

More information

Features XT SC 012 B B A

Features XT SC 012 B B A Motor Control and Protection. XT IEC Manual and Combination Motor Controllers Selection XT IEC Manual and Combination Motor Controllers Manual and Combination Motor Controllers Design XT = XT IEC power

More information

TX33 Models 28 W/ F (50 W/ C) TX23 Models 14 W/ F (25 W/ C) TX38 Models 56 W/ F (100 W/ C) TX52 Models 83 W/ F (150 W/ C)

TX33 Models 28 W/ F (50 W/ C) TX23 Models 14 W/ F (25 W/ C) TX38 Models 56 W/ F (100 W/ C) TX52 Models 83 W/ F (150 W/ C) CLIMAGUARD Air-to-Air Outdoor TX23 Models 14 W/ F (25 W/ C) TX33 Models 28 W/ F (50 W/ C) TX38 Models 56 W/ F (100 W/ C) TX52 Models 83 W/ F (150 W/ C) INDUSTRY STANDARDS ; Type 12, 4; 4X optional; File

More information

Cast Aluminum Circuit Breaker Interlocked Receptacle (Cutaway View)

Cast Aluminum Circuit Breaker Interlocked Receptacle (Cutaway View) 30A 400A (30 200A Load Breaking), Maximum 600VAC/250VDC Receptacles, Inlets, Plugs, Connectors, Interlocked Receptacles, Explosion-Proof Interlocked Receptacles Cast Aluminum Circuit Breaker Interlocked

More information

Dewatering. Series description Wilo-Drain STS 65. Submersible sewage pump

Dewatering. Series description Wilo-Drain STS 65. Submersible sewage pump Series description Wilo-Drain STS 65 Thermal winding monitoring Max. fluid temperature: 3-40 C Cable length: 10 m Free ball passage: 65 mm Max. immersion depth: 10 m Equipment/function Thermal motor monitoring

More information

Features XT SC 012 B B A

Features XT SC 012 B B A Motor Control and Protection. XT IEC Manual and Combination Motor Controllers Selection XT IEC Manual and Combination Motor Controllers Manual and Combination Motor Controllers Design XT = XT IEC power

More information

VM1700-VM1900 GATE VALVE GRINDING & LAPPING MACHINE

VM1700-VM1900 GATE VALVE GRINDING & LAPPING MACHINE VM1700-VM1900 GATE VALVE GRINDING & LAPPING MACHINE 2014 04 VM1700-1900 Powerful, rigid design with easy set up and handling. Powerful Wide working range: nominal diameter of 1.5-48 inches (40-1200 mm).

More information

Figure 1: Standard 906 Sensor and Pulser Disc. Figure 2: Standard 906 Sensor and Pulser Wrap

Figure 1: Standard 906 Sensor and Pulser Disc. Figure 2: Standard 906 Sensor and Pulser Wrap Description: The TR5000 is a Full Logic Control Process ratemeter that can display up to three separate values of rate and compare them to programmable set points. Rates A & B can be programmed by the

More information

Material: Weight: Bearing Life: Shaft Speed: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable:

Material: Weight: Bearing Life: Shaft Speed: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable: Automation / Mini Type 2RMHF Hollow Shaft Encoder - Ø 24 mm Hollow Bore: Ø 2 mm to Ø 1/4 inch Resolution up to 7.500 ppr IP 64 rating (IP 50 for flat cable option) Electrical Specifications Code: Resolution:

More information

Material: Weight: Shaft Speed: Starting Torque: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable:

Material: Weight: Shaft Speed: Starting Torque: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable: Automation / Mini Type 2RMHF Hollow Shaft Encoder - Ø 24 mm Hollow Bore: Ø 2 mm to Ø 1/4 inch Resolution up to 7.500 ppr IP 64 rating (IP 50 for flat cable option) Electrical Specifications Code: Resolution:

More information

HANNAY REELS. Audio/Video Reels. For use in: Production & Recording Facilities Television & Radio Stations

HANNAY REELS. Audio/Video Reels. For use in: Production & Recording Facilities Television & Radio Stations udio/video Reels NNY RLS or use in: Production & Recording acilities Television & Radio Stations Mobile roadcast Units Satellite & able ompanies Live vents & oncerts -9703-/V Rev. 3 Series V/VX udio/video

More information

Material: Weight: IP Rating: Cable: Connector:

Material: Weight: IP Rating: Cable: Connector: Automation / Mini Hollow Shaft Encoder - Ø 24 mm Hollow Bore: Ø 2 mm to Ø 6 mm Resolution up to 7.500 ppr IP 64 rating (IP 50 for flat cable option) Electrical Specifications Code: Resolution: Supply Voltage:

More information

Twin City Fan & Blower

Twin City Fan & Blower Twin City Fan & Blower BULLETIN 315 August 2000 SERIES 2000 DWDI BACKWARD INCLINED FANS TYPE BAB Series 2000 BAB DWDI Backward Inclined Fans This bulletin features our new BAB Series 2000 DWDI (double

More information

ATZAF FF DOUBLE INLET CENTRIFUGAL FANS WITH AIRFOIL BACKWARD CURVED BLADES

ATZAF FF DOUBLE INLET CENTRIFUGAL FANS WITH AIRFOIL BACKWARD CURVED BLADES ATZAF FF DOUBLE INLET CENTRIFUGAL FANS WITH AIRFOIL BACKWARD CURVED BLADES COMEFRI USA: Manufacturing and Warehouse facilities in Hopkinsville, KY. Total facility: 125,000 sq.ft. Producing centrifugal

More information

IK10 IP68. Specifications. White (4 300 K typical) Warm white (3 000 K typical) Blue (470 nm) Other colors by request

IK10 IP68. Specifications. White (4 300 K typical) Warm white (3 000 K typical) Blue (470 nm) Other colors by request 1300 Industrial Road, Unit #19 San Carlos, CA 94070 FREE CALL 1-866-695-5862 US & Canada info@lumascape.com LS553LED Via Ingrade IP68 IK10 The LS553LED is a rugged, side emitting marker light constructed

More information

Pilot Valves and Nema 4 Enclosures. Innovative Environmental Solutions

Pilot Valves and Nema 4 Enclosures. Innovative Environmental Solutions Pilot Valves and Nema 4 Enclosures Innovative Environmental Solutions Technical Specification Q Series Solenoid Solenoid used in the remote or integral actuation of dust collector diaphragm or pilot valves.

More information

Series 8800 Radial Tip Fans Design 8812

Series 8800 Radial Tip Fans Design 8812 Bulletin 8800-2 October 1996 Series 8800 Radial Tip Fans Design 8812 Description Index Series 8800 Radial Tip Fans The Design 8812 Radial Tip fan is a reliable, highly efficient, heavy duty, rugged fan

More information

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm Low-cost Encoder with Diameter of 50 mm CSM DS_E An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. High-precision detection of automatic machine timing.

More information

Series CDP2 Definite Purpose Contactors

Series CDP2 Definite Purpose Contactors Series CDP2 Definite Purpose Contactors High performance economical contactors for commercial applications up to 90 Sprecher + Schuh s Definite Purpose contactors are ideal for commercial applications

More information

T BTU/Hr Watts. T BTU/Hr Watts. Finish. Accessories. Options

T BTU/Hr Watts. T BTU/Hr Watts. Finish. Accessories. Options T-SERIES Mid-size Outdoor T29 4000 BTU/Hr. 1173 Watts T43, 8000, 10000 BTU/Hr., 2344, 2930 Watts T50 12000 BTU/Hr. 3516 Watts T53 19000 BTU/Hr. 5567 Watts Industry Standards UL/cUL Listed; Type 12, 3R,

More information

03-Durchfuehren_RZ_0708_EN.qxd:03-Durchfuehren GB.qxd :06 Uhr Seite 200 Feed-through

03-Durchfuehren_RZ_0708_EN.qxd:03-Durchfuehren GB.qxd :06 Uhr Seite 200 Feed-through Feed-through Feed-through FEED-THROUGH Series Size Page Rotary Feed-through for Robots DDF 202 DDF 031 206 DDF 040 208 DDF 040-1 210 DDF 050 212 DDF 050-1 214 DDF 063 216 DDF 080 218 DDF 080-1 220 DDF

More information

ENCODER. Incremental Angle Transducer. Series A36, A58. Key-Features:

ENCODER. Incremental Angle Transducer. Series A36, A58. Key-Features: ENCODER Incremental Angle Transducer Series A36, A58 Key-Features: Content: Technical Data A36...2 Technical Data A58...4 Elektrical Data...6 Accessories...7 Measuring Wheels...8 Order Code...9 - Incremental

More information

GENESIS Indoor Air Conditioners

GENESIS Indoor Air Conditioners PH FX ( Product Overview : Indoor Air Conditioners M28 Model M52 460 Volt 3-Phase Model M17 Model 74 74 Product Overview : The specifier s choice for cooling industrial process controls Indoor Air Conditioners

More information

General Wiring and Installation Guidelines. Typical Mounting Installations Electrical Connections General Guidelines Common Questions & Answers

General Wiring and Installation Guidelines. Typical Mounting Installations Electrical Connections General Guidelines Common Questions & Answers General Wiring and Installation Guidelines Typical Mounting Installations Electrical Connections General Guidelines Common Questions & Answers Congratulations on your purchase of a Dynapar brand encoder.

More information

INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS. Twin City Fan MODULAR PLENUM FANS MPLFN MPLFS MPLQN MPLQS CATALOG 495 APRIL 2013

INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS. Twin City Fan MODULAR PLENUM FANS MPLFN MPLFS MPLQN MPLQS   CATALOG 495 APRIL 2013 Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS MODULAR PLENUM FANS MPLFN MPLFS MPLQN MPLQS CATALOG 495 APRIL 2013 PLENUM FANS Models MPLFN MPLFS MPLQN MPLQS Twin City Fan & Blower

More information

SPECIFICATION NO Model 207 Automatic GTAW Welding System

SPECIFICATION NO Model 207 Automatic GTAW Welding System 1.0 Introduction The Model 207 is a completely self-contained Gas Tungsten Arc Welding (GTAW) System requiring only input power, inert gas and AMI Welding Head (or manual torch) for operation. Its small

More information

PT9420 Cable Actuated Sensor Industrial ma 0..20mA

PT9420 Cable Actuated Sensor Industrial ma 0..20mA PT9 Cable ctuated Sensor Industrial.. m 0..m bsolute Linear Position to 550 inches ( meters) luminum or Stainless Steel Enclosure Options VLS Option to Prevent Free-Release Damage IP68 / NEM 6 Hazardous

More information

RW45 Motor Gearboxes:. Drive torques up to 120Nm at 50 Hz and 60 Hz mains frequencies;

RW45 Motor Gearboxes:. Drive torques up to 120Nm at 50 Hz and 60 Hz mains frequencies; RW45 Motor Gearboxes Motor gearboxes RW45 Motor Gearboxes The RW45 motor gearboxes are maintenance-free, compact power units for driving ventilation, screen and flap ventilation systems in greenhouses

More information

Typical Roll Shutter Hood* Assembly

Typical Roll Shutter Hood* Assembly Typical Roll Shutter Hood* Assembly Override Motor * Various Hood sizes, styles & colors listed on Hurricane p34 Hurricane 26 website: www.easternmetal.com e-mail: info@easternmetal.com version: 11/05/13

More information

Series description: Wilo-Drain VC

Series description: Wilo-Drain VC Series description: Wilo-Drain VC 0H[m] 18 16 14 12 10 8 6 4 2 VC 32/10 Wilo-Drain VC 0 2 4 6 8 10 12 VC 40/20 Q[m³/h] Design Vertically-mounted drainage pump (pedestal pump with IE2 motor) Application

More information

Ultra Quiet Series Electric Air Handler

Ultra Quiet Series Electric Air Handler Residential & Light Commercial HVAC Ultra Quiet Series Electric Air Handler 1 1 2 thru 5 Tons 208/230 Volt, 1-Phase, 60 Hz The Fedders multi-position air handlers, when matched with our air conditioners

More information

Data sheet: Wilo-Drain TP 50 E 101/5,5 (1~230 V)

Data sheet: Wilo-Drain TP 50 E 101/5,5 (1~230 V) Data sheet: Wilo-Drain TP 50 E 101/5,5 (1~230 V) Pump curves Wilo-Drain TP 50 E - 50 Hz - 2900 rpm Unit Max. delivery head H max 9.5 m Max. volume flow Q max 26 m 3 /h Optimal delivery head H opt 5.0 m

More information

Butterfly Valve Retrofits

Butterfly Valve Retrofits Butterfly Valve Retrofits Contents How to Select the Butterfly Retrofit Solution... pg 127 Butterfly Valve Retrofit Actuators... pg 128 Solutions for Specific Manufacturer and Part Number Apollo... pg

More information

M BTU/Hr Watts. Finish. Options

M BTU/Hr Watts. Finish. Options Spec-00607 CPH FX ( Protective Cooling Air Conditioners Indoor Air Conditioners M13 1000 BTU/Hr. 293 Watt M17 1800 BTU/Hr. 527 Watt Industry Standards Maintains U/cUL Type 12 rating when properly installed

More information

For applications from 0.25 to 5 HP, the MD60 is a simple AC Microdrive that can be panel mounted as well as wall or machine mounted.

For applications from 0.25 to 5 HP, the MD60 is a simple AC Microdrive that can be panel mounted as well as wall or machine mounted. For applications from 0.25 to 5 HP, the MD60 is a simple AC Microdrive that can be panel mounted as well as wall or machine mounted. N223 Reliance Electric s MD60 AC Drive is ready to operate out-of-the-box!

More information

T BTU/Hr Watts

T BTU/Hr Watts 763.576.3200 Spec-00734 H763.422.2211 Sealed Enclosure Air Conditioners Sealed Enclosure Air Conditioners T-SERIES Mid-size Outdoor T29 4000 BTU/Hr. 1173 Watts T43, 8000, 10000 BTU/Hr., 2344, 2930 Watts

More information

Bulletin 109 TABLE OF CONTENTS Bulletin 109 IEC Non-Reversing Starters. Enclosed Type Molded Plastic. Description Page Description Page

Bulletin 109 TABLE OF CONTENTS Bulletin 109 IEC Non-Reversing Starters. Enclosed Type Molded Plastic. Description Page Description Page 3a Enclosed Type Molded Plastic Compact Design Impact-Resistant Molded Enclosures IP42 (Type 1) or IP66 (Type4/4X/12)Enclosure Ratings Solid-State Overload Relays Meets International Standards 109-C09KDA1E-1-4R1-7

More information

M SERIES DISPENSER M SERIES DISPENSER

M SERIES DISPENSER M SERIES DISPENSER M SERIES DISPENSER PART NUMBER 5006621 M SERIES DISPENSER M SERIES DISPENSER... M - 1 M15 TOP EXPLODED VIEW... M - 2 M15 TOP PARTS LIST... M - 3 M15 BASE EXPLODED VIEW... M - 4 M15 BASE PARTS LIST... M

More information

Dry Type Transformers Section 10

Dry Type Transformers Section 10 For more information on these products, order publications listed in Section 27. Find What You Need Faster - Page headings and table format make product selection easier. Easy Cross Reference - Frame size

More information

MODEL HS35 DRAWWORKS OPTICAL ENCODER

MODEL HS35 DRAWWORKS OPTICAL ENCODER MODEL HS35 DRAWWORKS OPTICAL ENCODER Product Description This specially configured DrawWorks Model HS35 encoder combines rugged, heavy-duty features into a unique through-shaft style for use as a winchturns

More information

T BTU/Hr Watts

T BTU/Hr Watts T-SERIES Mid-size Outdoor T29 4000 BTU/Hr. 1173 Watts T43, 8000, 10000 BTU/Hr., 2344, 2930 Watts T50 12000 BTU/Hr. 3516 Watts T53 19000 BTU/Hr. 5567 Watts INDUSTRY STANDARDS UL/cUL Listed; Type 12, 3R,

More information

Butterfly Valve Retrofits

Butterfly Valve Retrofits Butterfly Valve Retrofits Contents How to Select the Butterfly Retrofit Solution... pg 127 Butterfly Valve Retrofit Actuators... pg 128 Solutions for Specific Manufacturer and Part Number Apollo... pg

More information

PT9150. Heavy Industrial Incremental Encoder

PT9150. Heavy Industrial Incremental Encoder PT950 Heavy Industrial Incremental Encoder Linear Position to 550 inches (00 cm) luminum or Stainless Steel Enclosure Options VLS Option To Prevent Free-Release Damage IP67 NEM 6 Protection GENERL Full

More information

Butterfly Valve Retrofits

Butterfly Valve Retrofits Butterfly Valve Retrofits Contents How to Select the Butterfly Retrofit Solution... pg 127 Butterfly Valve Retrofit Actuators... pg 128 Solutions for Specific Manufacturer and Part Number Apollo... pg

More information

Single sensor setup with NIVEL210

Single sensor setup with NIVEL210 Single sensor setup with NIVEL210 Essential Items: 576 198 NIVEL210 RS232 748 335 Cable, Lemo 0 power supply cable Lemo 1 802 902 Cable, Lemo 0 722 409 Power supply plus power cords 802 902 576 198 748

More information

Butterfly Valve Retrofits

Butterfly Valve Retrofits Butterfly Valve Retrofits Contents How to Select the Butterfly Retrofit Solution... pg 127 Butterfly Valve Retrofit Actuators... pg 128 Solutions for Specific Manufacturer and Part Number Apollo... pg

More information

Electromagnetic Block Valves Direct Acting

Electromagnetic Block Valves Direct Acting Electromagnetic Block Valves Direct Acting Outline Drawing Models A B C D E NW16 2.50 2.28 4.43 1.58 1.58 (64) (58) (113) (40) (40) NW25 2.98 2.28 4.83 1.98 1.98 (76) (58) (123) (50) (50) Features Benefits

More information

GOYEN PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS CLEAN AIR SOLUTIONS PRODUCT LEAFLET

GOYEN PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS CLEAN AIR SOLUTIONS PRODUCT LEAFLET PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS CLEAN AIR SOLUTIONS 3-6VFD COMBINATION FLAME AND DUST IGNITION PROOF ENCLOSURES Goyen pilot valve enclosures for hazardous locations are available in a combination

More information