ErP ROOF UNITS - ROOFMASTER STOF VERTICAL FEATURES ELECTRICAL SUPPLY AMBIENT TEMPERATURE RANGE SIZES MATERIAL AND DESIGN
|
|
- Lewis Glenn
- 6 years ago
- Views:
Transcription
1 161 ROOF UNITS - ROOFMASTER STOF VERTICAL FEATURES 8 sizes Volume flows up to 4.7 m 3 /s Static Pressures up to 1050 Pa Both EC- and AC-versions available Insulated and non-insulated casing Low sound level High efficiency Speed controllable ErP 2015 compliant ELECTRICAL SUPPLY 230V/50Hz/1f 400V/50Hz/3f AMBIENT TEMPERATURE RANGE -20 C to +60 C (dependant on size) SIZES 190, 225, 310, 355, 400, 450, 500 and 630 mm 225, 310, 355, 400 mm available with insulated casing. MATERIAL AND DESIGN The fan casing is manufactured from black pre-painted galvanised sheet steel or aluminium and zinc coated sheet steel. The fan discharges air upwards. MOTOR AND IMPELLER The impeller has backward curved blades and is manufactured from polyamide (plastic) and is located inside the airstream. The motor is of the external rotor type.. 1 phase AC motors are equipped with thermal contact. See motor IP class in the motor table. INSTALLATION Fans are suitable for different roof curb mounting using an installation frame or can be fitted directly to roof base. PRODUCT CODE - STOF-190-VAC STOF-aaa-bbb-ccc-0 aaa = impeller diameter, e.g. 225 bbb V = vertical S = shutter bbb AC = AC-motor EC = EC-motor ccc 1 = 1-phase 3 = 3-phase ccc 0 = non insulated 1 = insulated ccc 1 = pre-painted galvanised sheet steel, black 2 = aluzinc 0 Generation ACCESSORIES - CONTROLLERS (Pages ) ErP COMPLIANT 2015 SPEED CONTROL Both AC and EC versions are available with speed control. EC motors are equipped with integral speed control for use with auxiliary 0-10v controller. AC motors can be controlled using a separate transformer speed control. DSM/DSC Adapter plate Controls Potentiometer Controls Transformer Isolator Switch
2 162 PRODUCT & ELECTRICAL DETAILS - 50 HZ EC STOF VERTICAL ROOF FAN Part Number (EC) Part Code Motor nominal data at 50 Hz Supply voltage Power kw Max current A Speed r/min Speed fan r/min Maximum Operating Temp C Isolator ErP COMPLIANT 2015 STOF-190-VEC SV x VAC 50/60 Hz EA STOF-225-VEC SV x VAC 50/60 Hz EA STOF-310-VEC SV x VAC 50/60 Hz EA STOF-355-VEC SV x VAC 50/60 Hz EA STOF-400-VEC SV x VAC 50/60 Hz EA STOF-450-VEC SV x VAC 50/60 Hz EA STOF-500-VEC SV x VAC 50/60 Hz EA STOF-630-VEC SV x VAC 50/60 Hz EA Vertical EC IP class Insulation Motor protection Speed Controller 0-10 V STOF-190-VEC B Internal TOP EA STOF-225-VEC B Internal TOP EA STOF-310-VEC B Internal TOP EA STOF-355-VEC B Internal TOP EA STOF-400-VEC B Internal TOP EA STOF-450-VEC B Internal TOP EA STOF-500-VEC B Internal TOP EA STOF-630-VEC B Internal TOP EA AC STOF VERTICAL ROOF FAN Part Number (AC) Part Code Motor nominal data at 50 Hz Supply voltage Power kw Max current A Speed r/min Speed fan r/min Maximum Operating Temp C Isolator STOF-190-VAC SV x230V 50/60 Hz EA STOF-225-VAC SV x230V 50/60 Hz EA STOF-310-VAC SV x230V 50/60 Hz EA STOF-355-VAC SV x 230 V 50 Hz EA STOF-355-VAC SV x230VD 50/60Hz/ 3x400VY 50/60 Hz EA STOF-400-VAC SV x230V 50/60 Hz EA STOF-400-VAC SV x400VYD 50 Hz/ 3x400 VYD 60 Hz EA STOF-450-VAC SV x230VD/400VY 50 Hz EA STOF-500-VAC SV x230VD/400VY 50 Hz EA Vertical AC IP class Insulation Motor protection Transformer Current A IP class Voltage STOF-190-VAC B Internal TOP EA VAC 50/60 Hz STOF-225-VAC F Internal TOP EA VAC 50/60 Hz STOF-310-VAC B Internal TOP EA VAC 50/60 Hz STOF-355-VAC F Internal TOP EA VAC 50/60 Hz STOF-355-VAC F TOP brought out EA VAC 50/60 Hz STOF-400-VAC F TOP brought out EA VAC 50/60 Hz STOF-400-VAC F TOP brought out EA VAC 50/60 Hz STOF-450-VAC F TOP brought out EA VAC 50/60 Hz STOF-500-VAC F TOP brought out EA VAC 50/60 Hz The part numbers shown above are for the standard un-insultated, aluzinc finish. Wiring diagrams, please see pages Products in bold are available from our UK Distributors on next day delivery, if ordered by 4pm. Please call to confirm availability on
3 163 K OCT FACTORS FOR SOUND DATA (STOF, VERTICAL, UNINSULATED) K Oct Correction factors (db) Octave band mid-frequency (Hz) Fan code Sound path MinRPM MaxRPM STOF-190-Vbb-10c-0 Surroundings STOF-190-Vbb-10c-0 Surroundings STOF-190-Vbb-10c-0 Surroundings STOF-190-Vbb-10c-0 Surroundings STOF-190-Vbb-10c-0 To the inlet duct STOF-190-Vbb-10c-0 To the inlet duct STOF-190-Vbb-10c-0 To the inlet duct STOF-190-Vbb-10c-0 To the inlet duct STOF-225-Vbb-10c-0 Surroundings STOF-225-Vbb-10c-0 Surroundings STOF-225-Vbb-10c-0 To the inlet duct STOF-225-Vbb-10c-0 To the inlet duct STOF-310-Vbb-10c-0 Surroundings STOF-310-Vbb-10c-0 Surroundings STOF-310-Vbb-10c-0 To the inlet duct STOF-310-Vbb-10c-0 To the inlet duct STOF-355-Vbb-10c-0 Surroundings STOF-355-Vbb-10c-0 Surroundings STOF-355-Vbb-10c-0 To the inlet duct STOF-355-Vbb-10c-0 To the inlet duct STOF-355-Vbb-30c-0 Surroundings STOF-355-Vbb-30c-0 Surroundings STOF-355-Vbb-30c-0 To the inlet duct STOF-355-Vbb-30c-0 To the inlet duct STOF-400-Vbb-10c-0 Surroundings STOF-400-Vbb-10c-0 Surroundings STOF-400-Vbb-10c-0 To the inlet duct STOF-400-Vbb-10c-0 To the inlet duct STOF-400-Vbb-30c-0 Surroundings STOF-400-Vbb-30c-0 Surroundings STOF-400-Vbb-30c-0 To the inlet duct STOF-400-Vbb-30c-0 To the inlet duct STOF-450-Vbb-30c-0 Surroundings STOF-450-Vbb-30c-0 Surroundings STOF-450-Vbb-30c-0 To the inlet duct STOF-450-Vbb-30c-0 To the inlet duct STOF-500-Vbb-30c-0 Surroundings STOF-500-Vbb-30c-0 Surroundings STOF-500-Vbb-30c-0 To the inlet duct STOF-500-Vbb-30c-0 To the inlet duct STOF-630-Vbb-30c-0 Surroundings STOF-630-Vbb-30c-0 Surroundings STOF-630-Vbb-30c-0 To the inlet duct STOF-630-Vbb-30c-0 To the inlet duct
4 164 K OCT FACTORS FOR SOUND DATA (STOF, VERTICAL, INSULATED) K Oct Correction factors (db) Octave band mid-frequency (Hz) Fan code Sound path MinRPM MaxRPM STOF-225-Vbb-11c-0 Surroundings STOF-225-Vbb-11c-0 Surroundings STOF-225-Vbb-11c-0 To the inlet duct STOF-225-Vbb-11c-0 To the inlet duct STOF-310-Vbb-11c-0 Surroundings STOF-310-Vbb-11c-0 Surroundings STOF-310-Vbb-11c-0 To the inlet duct STOF-310-Vbb-11c-0 To the inlet duct STOF-355-Vbb-11c-0 Surroundings STOF-355-Vbb-11c-0 Surroundings STOF-355-Vbb-11c-0 To the inlet duct STOF-355-Vbb-11c-0 To the inlet duct STOF-355-Vbb-31c-0 Surroundings STOF-355-Vbb-31c-0 Surroundings STOF-355-Vbb-31c-0 To the inlet duct STOF-355-Vbb-31c-0 To the inlet duct STOF-400-Vbb-11c-0 Surroundings STOF-400-Vbb-11c-0 Surroundings STOF-400-Vbb-11c-0 To the inlet duct STOF-400-Vbb-11c-0 To the inlet duct STOF-400-Vbb-31c-0 Surroundings STOF-400-Vbb-31c-0 Surroundings STOF-400-Vbb-31c-0 To the inlet duct STOF-400-Vbb-31c-0 To the inlet duct
5 165 PERFORMANCE TABLES EC STOF VERTICAL ROOF FAN Pressure (Pa) Vertical EC STOF-190-VEC-10c STOF-225-VEC-10c STOF-310-VEC-10c STOF-355-VEC-10c STOF-400-VEC-10c STOF-450-VEC-30c STOF-500-VEC-30c STOF-630-VEC-30c Airflow m 3 /s Pressure (Pa) Insulated EC STOF-225-VEC-10c STOF-310-VEC-10c STOF-355-VEC-10c STOF-400-VEC-10c Airflow m 3 /s AC STOF VERTICAL ROOF FAN Pressure (Pa) Vertical AC STOF-190-VAC-10c STOF-225-VAC-10c STOF-310-VAC-10c STOF-355-VAC-10c STOF-355-VAC-30c STOF-400-VAC-10c STOF-400-VAC-30c STOF-450-VAC-30c STOF-500-VAC-30c STOF-630-VAC-30c Airflow m 3 /s Pressure (Pa) Insulated AC STOF-225-VAC-10c STOF-310-VAC-10c STOF-355-VAC-10c STOF-355-VAC-30c STOF-400-VAC-10c STOF-400-VAC-30c Airflow m 3 /s Performance table is valid for both aluzinc and black casing.
6 166 FAN CHART - EXPLANATION AND DEFINITIONS SYMBOLS 1. qv Air flow m 3 /s, m 3 /h 2. Δp t Static pressure Pa 3. η Total fan efficiency % 4. L wa A-weighted total sound power level L pa A-weighted total sound pressure level ΔL Remote attenuation db SOUND PRESSURE LEVEL db(a) db(a) The total A-weighted sound power level, L wa emitted from the power roof ventilator to the surroundings can be read in the chart. The sound pressure level at different distances from the power roof ventilator can be determined by using the following formula: L pa = L wa - ΔL Distance L (m) Attenuation ΔL (db) SOUND LEVEL AT DIFFERENT OCTAVE BANDS Correction Koct (db) Octave band mid-frequency (Hz) Sound path MinRPM MaxRPM Surroundings To the inlet duct The total A-weighted sound power level, LwA, emitted from the power roof ventilator to the surroundings can be read in the fan chart. The sound power level by octave band to the surroundings and to the inlet duct (without A-weighting) can be obtained by using the following formula: L woct =L wa + K oct. The corrections are given in Koct table for both sound paths and correct speed area.
7 167 PERFORMANCE CHARTS FAN CHART, VERTICAL NON INSULATED STOF-190 STOF VEC -1- SV STOF VAC -1 - SV FAN CHART, VERTICAL NON INSULATED STOF-225 STOF VEC -1- SV STOF VAC -1- SV221102
8 168 PERFORMANCE CHARTS FAN CHART, VERTICAL NON INSULATED STOF-310 STOF VEC -1 - SV STOF VAC -1 - SV FAN CHART, VERTICAL NON INSULATED STOF-355 STOF VAC -1 SV STOF VAC SV STOF VEC -1 SV353102
9 169 PERFORMANCE CHARTS FAN CHART, VERTICAL NON INSULATED STOF-400 STOF VEC -1 - SV STOF VAC SV STOF VAC -1 - SV FAN CHART, VERTICAL NON INSULATED STOF-450 STOF VEC SV STOF VAC SV453302
10 170 PERFORMANCE CHARTS FAN CHART, VERTICAL NON INSULATED STOF-500 STOF VEC SV STOF VAC SV FAN CHART, VERTICAL NON INSULATED STOF-630 STOF VEC SV633302
11 171 DRAWING AND DIMENSIONS Uninsulated vertical Fan size A H L in L out W in W out Weight All dimensions shown in mm
12 172 WIRING DIAGRAMS - STOF STOF AC 1ph 190, 225, 310, 355 STOF AC 1ph 400 STOF 190 AC 1PH STOF 225 AC 1PH STOF 310 AC 1PH STOF 355 AC 1PH STOF 400 AC 1PH CAPACITOR CAPACITOR YELLOW- YELLOW- TO BE SUPPLIED BY A SUITABLE RATED SUPPLY N L E EXTERNAL SAFETY CIRCUIT (2AMP MAX 240v) N L E TO BE SUPPLIED BY A SUITABLE RATED SUPPLY STOF AC 3ph 355, 450, 500, 630 WHITE YELLOW YELLOW- FACTORY FITTED TWO LINK CABLES EXTERNAL SAFETY CIRCUIT 240v 2Amp MAX L3 L2 L1 PE TO BE SUPPLIED BY A SUITABLE RATED SUPPLY
13 173 WIRING DIAGRAMS - STOF STOF EC 1ph 190, 225, 310, 355 STOF EC 1ph 400 TACHO 10v WHITE RED YELLOW YELLOW- RED YELLOW WHITE WHITE YELLOW- SPEED POTENTIOMETER SDP V10 SDP V230 10volt 0-10v GND 0-10v GND BMS N L PE TO BE SUPPLIED BY A SUITABLE RATED SUPPLY 240v EXTERNAL SAFETY CIRCUIT 2Amp MAX N L PE TO BE SUPPLIED BY A SUITABLE RATED SUPPLY STOF EC 3ph 450 STOF EC 3ph 500, 630 STOF 450 EC 3PH RED WHITE RED WHITE YELLOW- YELLOW- t10v 0-10v BMS GND t10v BMS Ain 1U/0-10v GND ALARM RELAY 240V NC MAX 2 AMP RATE NO COM L3 L2 L1 PE TO BE SUPPLIED BY A SUITABLE RATED SUPPLY ALARM RELAY 240V MAX 2 AMP RATE NC NO COM L3 L2 L1 PE TO BE SUPPLIED BY A SUITABLE RATED SUPPLY
14 ALSO AVAILABLE FROM THE WOODS RANGE JMv Aerofoil MaXfan 2 JM Aerofoil HT JM Aerofoil JM Bifurcated Series 33 Plate Fans Cased & Plate Axial Accessories Tube Fans Sabina EC Box Fans Daisho AC Box Fans Daisho EC Box Fans Estoc Estoc Targe Estoc EC Tube & Box Accessories Roof Units Horizontal Roof Units Vertical Fire Dampers Iris Dampers Fire Valves Valves Supply KE Valves Extract KK Valves Exhaust VEFS Nozzles DK & DR Louvres/ Cowls EYMA and DYMA External Louvres USAV Controllers Selected products available from our UK Distributors on next day delivery, if ordered by 4pm. Please call for more information.
AC diagonal module Ø 200 mm
max. 850 m /h C diagonal module Ø 00 mm Material: Housing: Plastic P Support bracket: Plastic P Impeller: Plastic P Rotor: Coated in black Number of blades: 7 Direction of air flow: "V" Direction of rotation:
More informationSIDE CHANNEL BLOWERS. Voltage Δ / Y 2 V 230/ / / / / /460 - Current Δ / Y Revolutions
DB411/415/422/ DESCRIPTION Dutair blowers for pressure and vacuum are compact machines consisting of an electric motor with a built-on pump housing. The rotational speed of the impeller creates a high
More informationProduct Data Sheet 4656 EZ
The engineer's choice 4656 EZ INDEX 1 General... 3 2 Mechanics... 3 2.1 GENERAL... 3 2.2 CONNECTIONS... 4 3 Operating Data... 5 3.1 ELECTRICAL OPERATING DATA... 5 3.2 OPERATING DATA - ELECTRICAL INTERFACE
More informationProduct Data Sheet 8506 VW-691
The engineer's choice 8506 VW-691 INDEX 1 General... 3 2 Mechanics... 3 2.1 GENERAL... 3 2.2 CONNECTIONS... 4 3 Operating Data... 5 3.1 ELECTRICAL OPERATING DATA... 5 3.2 OPERATING DATA - ELECTRICAL INTERFACE
More informationROOF FANS RANGE INDUSTRIAL VENTILATION NEW
www.vortice.com ROOF FANS RANGE INDUSTRIAL VENTILATION NEW HEADQUARTERS VORTICE IN THE WORLD Founded in 197, Vortice France is located at Crétail about 1 Km from Paris. Our current Vortice Headquarters
More informationR87B. Box Fan. Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting. Ordering Information. Model Number Structure
Box Fan R87B CSM_R87B_DS_E_4_2 Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting Mounts in a square cutout and conceals the hole-cut to simplify installation work.
More informationProduct Data Sheet 4650 N-465
The engineer's choice 4650 N-465 INDEX 1 General... 3 2 Mechanics... 3 2.1 GENERAL... 3 2.2 CONNECTIONS... 4 3 Operating Data... 5 3.1 ELECTRICAL OPERATING DATA... 5 3.2 ELECTRICAL FEATURES... 5 3.3 AERODYNAMIC...
More informationProduct Data Sheet 4656 ZW
The engineer's choice 4656 ZW INDEX 1 General... 3 2 Mechanics... 3 2.1 GENERAL... 3 2.2 CONNECTIONS... 4 3 Operating Data... 5 3.1 ELECTRICAL OPERATING DATA... 5 3.2 OPERATING DATA - ELECTRICAL INTERFACE
More informationLINEAR ACTUATORS. Type S / SH 95, S / SH 80, S / SH 71, S / SH 56
LINEAR ACTUATORS Type S / SH 95, S / SH 80, S / SH 71, S / SH 56 moving As one of the leading manufacturers of electrical and electronic drive components and systems we offer you a wide product range for
More informationInstallation Operation Maintenance
Installation Operation Maintenance Rooftop Energy Recovery Module for TKD / TKH / WKD / WKH YKD / YKH / DKD / DKH # 125-155-175-200 250 265-290-340 # 275-300-350-400-500-600 April 2011 RT-SVX42B-E4 General
More informationActuator for dampers ACCESSORIES. Actuators for air dampers control in ventilation and air-conditioning systems.
SP Actuator for dampers CM230-1-F-L LF 230 TF 230 LM230A-TP LM24A-TP LM230A-SR-TP NM24A-TP NM230A-TP NM24A-SR-TP NF230A NF24A SF24A SF230A SF24A-SR SM230A-TP SM24A-TP SM24A-SR-TP ZAKP0027 ZAKP0039 ZAKP0063
More informationSTE Technic Project Engineering Services Trade Ltd. Co. General Information. Main Features. Proven Performance
Technic Cross-Flow Fans T R A N S F O R M E R C O O L I N G S O L U T I O N S Transformer Cross-Flow Fans General Information provides optimal solutions for air forced cooling of transformers. High performance
More informationINDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS. Twin City Fan MODULAR PLENUM FANS MPLFN MPLFS MPLQN MPLQS CATALOG 495 APRIL 2013
Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS MODULAR PLENUM FANS MPLFN MPLFS MPLQN MPLQS CATALOG 495 APRIL 2013 PLENUM FANS Models MPLFN MPLFS MPLQN MPLQS Twin City Fan & Blower
More informationKüba comfort DP. Draught-free ventilation and extremely quiet operation
Draught-free ventilation and extremely quiet operation engineering for a better world GEA Heat Exchangers Draught-free ventilation and extremely quiet operation Low air speed in the cold room Integrated
More informationSERIES 400 SERIES 620
x 0. 0... PUR cable type,000 Hz SERIES 00 SERIES 0 0,000 Hz Table Diagram ---.... 9 VDC /. ma** PUR cable type / Connector S,000 Hz 0,000 Hz Table Diagram ---.... 9 VDC /. ma** PUR cable type,000 Hz x
More informationSeries description: Wilo-Drain VC
Series description: Wilo-Drain VC 0H[m] 18 16 14 12 10 8 6 4 2 VC 32/10 Wilo-Drain VC 0 2 4 6 8 10 12 VC 40/20 Q[m³/h] Design Vertically-mounted drainage pump (pedestal pump with IE2 motor) Application
More informationFlygt D 8050, 50 Hz. Technical specification
Flygt D 8050, 50 Hz Technical specification Table of Contents Table of Contents D 8050... 2 Product... 2 Denomination... 2 Process data... 2 Motor data...2 Cable...2 Monitoring equipment... 2 Material...
More informationAir Flow Static Pressure Characteristics MU1238A MU1238B MU1238L. Static Pressure. Static Pressure. Speed [r/min] [Pa] Speed
Cooling Fans MU Series Slim-Line, General-Purpose s 4.69 in. 1.5 in. thick ( 119 mm 38 mm thick) Ambient Temperature: 14 F to 14 F ( 1 C to 6 C) Operating Voltage Range: 1% Materials Frame: Die Cast Aluminum
More informationR87B. Box Fan. Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting. Model Number Structure. Ordering Information
Box Fan R87B CSM_R87B_DS_E_4_4 Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting Mounts in a square cutout and conceals the hole-cut to simplify installation work.
More informationSeries description: Wilo-Sub TWU 3 HS
Series description: Wilo-Sub TWU 3 HS Design Submersible pump, multistage Application For private water supply from boreholes, wells and rainwater storage tanks For domestic water supply, sprinkling and
More informationCENTRAL BLOWER COMPANY 211 S. 7th Ave. City of Industry, CA (626) Fax (626)
CENTRAL BLOWER COMPANY 211 S. 7th Ave. City of Industry, CA 91746 (626) 330-3182 Fax (626) 330-9406 www.centralblower.com CATALOG REF-11 OCTOBER 2011 Series RE Scoop with Grease Trough Sealed to blower
More informationSplit System Air Conditioner
Residential & Light Commercial HVAC Split System Air Conditioner 1 R-410A, 1 2 thru 5 Tons 208/230 Volt, 1-Phase, 60 Hz Performance: Efficiency rating of 13 SEER Cooling capacities from 1 1 2 to 5 tons
More informationwith handle LIMOGES Cedex 1. DESCRIPTION - USE 3. DIMENSIONS Symbol: Technology: Use:. For controlling a load remotely via a switch 2.
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 25A power contactors silent CONTENTS PAGES 1. Description, use... 1 2. Range... 1 3. Dimensions... 1 4. Positioning - Connection...
More informationDewatering. Series description Wilo-Drain STS 65. Submersible sewage pump
Series description Wilo-Drain STS 65 Thermal winding monitoring Max. fluid temperature: 3-40 C Cable length: 10 m Free ball passage: 65 mm Max. immersion depth: 10 m Equipment/function Thermal motor monitoring
More informationSERIES x5. Nickel-plated brass Connection 1) PUR cable type 1 Degree of protection. IP 67 Mounting. Embeddable Max. switching frequency
1 Size SERIES 400 x SERIES x Operating distance mm 0.8 0.8 1. Housing material Connection 1) PUR cable type 1 PUR cable type 1 / Connector S8 PUR cable type 1 Degree of protection Mounting Max. switching
More informationATZAF FF DOUBLE INLET CENTRIFUGAL FANS WITH AIRFOIL BACKWARD CURVED BLADES
ATZAF FF DOUBLE INLET CENTRIFUGAL FANS WITH AIRFOIL BACKWARD CURVED BLADES COMEFRI USA: Manufacturing and Warehouse facilities in Hopkinsville, KY. Total facility: 125,000 sq.ft. Producing centrifugal
More informationKüba compact DF. The space-saving helper in filling stations, gastronomy and the trade
The space-saving helper in filling stations, gastronomy and the trade The space-saving helper in the positive and negative range Straightforward mounting Integrated air baffle plate Extremely space-saving
More informationImmersion Pumps HCT (High Chem) sealless
Immersion Pumps HCT (High Chem) sealless 1-6004-US Centrifugal pumps of plastic for a wide variety of industrial fluids Technical data Delivery rate Q max = 120 l/min Delivery head H max = 32 m Temperature
More informationTURNING AIR INTO SOLUTIONS. DIRECT DRIVE MIXED FLOW INDUCED FLOW EXHAUST FANS. Model TVIFE
TURNING AIR INTO SOLUTIONS. 60 2 CA AM ted tes DIRECT DRIVE MIXED FLOW INDUCED FLOW EXHAUST S Model TVIFE CATALOG 1090 September 2016 LABORATORY EXHAUST S Overview TVIFE TVIFE Single Unit Twin City Fan
More informationPBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories
PBC series IEC-Type Contactors & Accessories 9-80 Amp AC-3, 25-125 Amp AC-1 AC Coils File E38802 (PBC) RoHS Ready Users should thoroughly review the technical data before selecting a product part number.
More informationModular pulse operated latching relay 16 A
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 Modular pulse operated latc / 05 / 07 / 08 / 10 / 11 / 12 / 14 / 16 / 20 and 927 00 / 49 CONTENTS PAGES 1. Description,
More information3/2-directional valve, electrically operated, Series AS3-SOV G 3/8 - G 1/2 pipe connection ATEX optional
Preparation of compressed air Maintenance units and components 1 IM0046156 Version Poppet valve, Can be assembled into blocks Nominal flow 4500 l/min Nominal flow, 1 2 4500 l/min Nominal flow, 2 3 3200
More informationCENTRAL BLOWER COMPANY 211 S. 7th Ave. City of Industry, CA (626) Fax (626)
CENTRAL BLOWER COMPANY 211 S. 7th Ave. City of Industry, CA 91746 (626) 330-3182 Fax (626) 330-9406 www.centralblower.com CATALOG REF - 01 JULY, 2001 Series RE Scoop with Grease Trough Sealed to blower
More informationMIKRO POWER FACTOR CORRECTION COMPONENTS
MIKRO POWER FACTOR CORRECTION COMPONENTS MIKRO POWER FACTOR REGULATOR Steps 6, 8, 12, 14 Voltage 1 4V AC Frequency 0 and 60 Hz Detection method Displacement Power Factor Input current A Modes Automatic,
More informationTwin City Fan & Blower
Twin City Fan & Blower BULLETIN 315 August 2000 SERIES 2000 DWDI BACKWARD INCLINED FANS TYPE BAB Series 2000 BAB DWDI Backward Inclined Fans This bulletin features our new BAB Series 2000 DWDI (double
More informationGear Pump Units For single-line centralized lubrication systems
1-1202-EN Gear ump Units For single-line centralized lubrication systems MFE5-KW3-2 MFE5-KW6 MFE5-BW7 These units comprising the MFE Group are designed to supply the lubricant used in intermittently operated,
More informationFluid Cooling P-BAR b Industrial BOL Series
Fluid Cooling P-BAR b Industrial BOL Series 10 BRAZED ALUMINUM CONSTRUCTION Performance Notes Bar and plate brazed aluminum core Provides the best heat transfer per given envelope size while minimizing
More informationUltra Quiet Series Electric Air Handler
Residential & Light Commercial HVAC Ultra Quiet Series Electric Air Handler 1 1 2 thru 5 Tons 208/230 Volt, 1-Phase, 60 Hz The Fedders multi-position air handlers, when matched with our air conditioners
More informationHigh efficiency pumps with LCD display electronically controlled HEP Optimo L series, H2 product group
High efficiency pumps with LCD display electronically controlled HEP Optimo L series, H2 product group indicate which mode has been active or selected. By pressing the activation pushbutton for more than
More informationPhotoelectrics Through-beam Type PA18C.T..., DC
Photoelectrics Through-beam Type, DC Miniature sensor range Range: 20 m (Axial), 16 m (Radial) Sensitivity adjustment by potentiometer Modulated, infrared light 850 nm Supply voltage: to 30 VDC Output:
More informationI Ex-protected connectors exlink I
Y-Junction-box Technical data Y-Junction-box / Marking to 94/9/EC II 2 G Ex de IIC T6/T5 / II 2D Ex td A21 T80 C/ T95 C EC-Type Examination Certificate PTB 05 ATEX 1084 IECEx-Certificate of Conformity
More informationWCHE BTU/Hr Watts
763.576.3200 SPEC-01037 A763.422.2211 COOLING SEALED ENCLOSURE COOLING HEAT EXCHANGERS Sealed Enclosure Cooling Heat Exchangers CLIMAGUARD AIR-TO-WATER INDOOR HEAT EXCHANGERS WCHE01 2968 BTU/Hr. 870 Watts
More informationProduct catalogue 2010
Product catalogue 2010 welding, cutting and more... www.kemper.eu Extraction systems for the electronic industry Soldering workstations... 153-154 Soldering smoke extraction systems... 155 Accessories
More informationCENTRIFAN IN-LINE CENTRIFUGAL FAN
CENTRIFAN IN-LINE CENTRIFUGAL FAN The Peerless Electric Centrifan represents the latest development in the fan and blower industry. Incorporating the tried and proven, highly efficient Peerless wheel in
More informationData sheet: Wilo-Drain TP 50 E 101/5,5 (1~230 V)
Data sheet: Wilo-Drain TP 50 E 101/5,5 (1~230 V) Pump curves Wilo-Drain TP 50 E - 50 Hz - 2900 rpm Unit Max. delivery head H max 9.5 m Max. volume flow Q max 26 m 3 /h Optimal delivery head H opt 5.0 m
More informationWCHE BTU/Hr Watts
763.576.3200 SPEC-00754 F763.422.2211 THERMAL MANAGEMENT SEALED ENCLOSURE COOLING HEAT EXCHANGERS Sealed Enclosure Cooling Heat Exchangers CLIMAGUARD AIR-TO-WATER INDOOR WCHE01 2968 BTU/Hr. 870 Watts WCHE04/WCHE06
More informationRoots pumps with a pumping speed of 280 to 840 m 3 /h: Okta 500 DUO DN1 DN B A
3.1 Vacuum generation / / Convection cooled OktaLine Okta 500 with a pumping speed of 280 to 840 m 3 /h: High-performance Roots pump with a pumping speed of 280 to 840 m 3 /h With 3-phase motor, IE2 No
More informationNew SV series / Holger Falk / Distributor meeting Page 2
New SV series / Holger Falk / Distributor meeting 2014 Page 2 New SV-series: Integrated accessories More compact design of SV300 with integrated accessories by new design of filter housing Larger effective
More informationTUC: Universal thermostat
Product data sheet 3.1 21.700 TUC: Universal thermostat How energy efficiency is improved Control, monitoring and limiting according to needs and with no auxiliary energy. Features Regulates and monitors
More informationHorn loudspeaker, Ex proof, short/long flare
Horn loudspeaker, Ex proof, short/long flare LH3 UC25XS, LH3 UC25XL en Installation note Horn loudspeaker, Ex-proof, short/long flare Installation en 3 1 Installation 1 2 Figure 1.1 Figure 1.2 4X Figure
More informationCME500 SERVICE PARTS
This section contains the parts illustrations and parts lists for the CME500. CME500 ice machines are manufactured in both 115 volt, 60 cycle and 220 volt, 50 cycle. When ordering electrical parts, be
More informationSWA Cable BS6724 Steel Wire Armoured LSZH Eland Product Group A9L
SWA Cable BS6724 Steel Wire Armoured LSZH Eland Product Group A9L Application SWA Cable power and auxiliary control cables for use in power networks, underground, outdoor and indoor applications and for
More informationSeries description: Wilo-Jet HWJ
Series description: HWJ 2 Design Self-priming water-supply unit Application Water supply Sprinkling Irrigation and spraying Pumping water from wells and out of low-lying tanks Type key Example: H WJ HWJ
More informationDHK DHK-NW MEDIUM PRESSURE FRP CENTRIFUGAL FAN HIGH PRESSURE FRP CENTRIFUGAL FAN
DHK MEDIUM PRESSURE FRP CENTRIFUGAL DHK-NW HIGH PRESSURE FRP CENTRIFUGAL INTRODUCTION AND FEATURES We are pleased to provide you with this Engineering brochure for the DHK Medium Pressure and DHK-NW High
More informationENCODER. Incremental Angle Transducer. Series A36, A58. Key-Features:
ENCODER Incremental Angle Transducer Series A36, A58 Key-Features: Content: Technical Data A36...2 Technical Data A58...4 Elektrical Data...6 Accessories...7 Measuring Wheels...8 Order Code...9 - Incremental
More informationPhone Horizontal Multistage Pumps Horizontal Stainless Steel Multistage Pumps 3, 6, 9 m³/h
Horizontal Stainless Steel Multistage Pumps 3, 6, 9 m³/h Horizontal Multistage Pumps 50 Hz Stainless Steel 3-9 m3/h Model Number Explanation Example: 3AMH2B-51 3 = m 3 /h AMH = Series 2 = # of Stages
More informationData sheet: Wilo-Drain TP 65 E 114/11 (1~230 V)
Data sheet: Wilo-Drain TP 65 E 114/11 (1~230 V) Pump curves Wilo-Drain TP 65 E - 50 Hz - No. of poles: 2 Unit Max. delivery head H max 15.0 m Max. volume flow Q max 52.0 m 3 /h Optimal delivery head H
More informationLinear flow control with actuator IFC
Linear flow control with actuator Product brochure GB 3 Edition 01.14 Linear relationship between adjustment angle and flow rate Large control ratio of 25:1 EC type-tested and certified Actuators IC 20
More informationAxial Fan, 4 in, Bulletin D85 (Hoffman Thermal Management
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 Catalog Number Manufacturer Description Weight per unit Product Category A4AXFN24 4", 24VDC Cooling Fan Hoffman Enclosures,
More informationMax. temp. of sensor C. Capillary tube mm. Switching difference K. Sensor cartridge mm
21.610/1 RAK: Universal thermostat How energy efficiency is improved Demand-led controlling, monitoring and limiting, without auxiliary energy. Areas of application For controlling and monitoring the temperature
More informationWCHE BTU/Hr Watts
Spec-00754 B Sealed Enclosure Heat Exchangers Sealed Enclosure Heat Exchangers CLIMAGUARD Air-to-Water Indoor WCHE01 2968 BTU/Hr. 870 Watts WCHE04/WCHE06 7506/10577 BTU/Hr. 2200/3100 Watts WCHE14 22861
More informationXR47-24 Models 24 W/ F (43 W/ C)
CLIMAGUARD AIR-TO-AIR INDOOR XR20 Models 4 W/ F (7 W/ C) XR29-08 Models 8 W/ F (14 W/ C) XR29-18 Models 18 W/ F (32 W/ C) XR47-24 Models 24 W/ F (43 W/ C) XR47-35 Models 35 W/ F (63 W/ C) XR60-55 XR60-84
More informationtechnical data (according to IEC ) Degree of protection IP 67 Max. ripple content 15 % U B / 20 % U B (amplifier) No-load supply current
Inductive Sensors: high-temperature ü For ambient temperatures of up to +230 C ü With integrated electronics, up to +180 C ü With external electronics, up to +230 C ü Excellent long-term reliability (according
More informationSMALL OIL SEALED PUMPS
SMALL OIL SEALED PUMPS PERFORMANCE YOU CAN RELY ON EM0.7 and.5 Oil Sealed Rotary Vane Pumps 8 RV Oil Sealed Rotary Vane Pumps 86 RV ATEX Oil Sealed Rotary Vane Pumps 94 EM8 and 8 Oil Sealed Rotary Vane
More informationWall-/Pipe-Mount Level Indicator
Data Sheet SS/_4 Wall-/Pipe-Mount Level Indicator High visibility 5-digit LED display clear multi-functional indication Analog and 2-relay outputs as standard high, low, latch and rate alarms, plus isolated
More informationLC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil
Product data sheet Characteristics LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationN43 N36 N28. Sealed Enclosure Cooling Air Conditioners
SPECTRACOOL NARROW INDOOR/OUTDOOR N43 N36 N28 11000 BTU/Hr. / BTU/Hr. BTU/Hr. 3223 Watt / Watt Watt INDUSTRY STANDARDS UL/cUL Listed; Type 12, 3R, 4; 4X optional; File No. SA6453 CE IP 56 Internal Loop
More informationEVAPORATIVE COOLER. ...Simple Effective Inexpensive to operate Economical. MODEL EC2.5 EC to CFM Nominal Airflow
...Simple Effective Inexpensive to operate Economical The Saudi Factory for Air Conditioning Units No air cooled condenser needed No chiller or cooling tower needed No major control center No refrigerant
More informationENCODER. Incremental Angle Transducer. Series A36, A58. Key-Features:
ENCODER Incremental Angle Transducer Series A36, A58 Key-Features: Content: Technical Data A36...2 Technical Data A58...4 Elektrical Data...6 Accessories...7 Measuring Wheels...8 Order Code...9 - Incremental
More informationDirect PWM. 1000/2000 Series POWERBLOK MODULE
Direct PWM 1000/2000 Series POWERBLOK MODULE Features A universal servo-drive integrated on a Power Hybrid Module. Designed for direct PWM Servo Control Designed for use with Deta Tau's PMAC controllers
More informationAdmiss. counterpressure
in survey Multi-layer diaphragm technology High dosing accuracy Safe to run dry High quality materials Leakage-free Low maintenance User-friendly Integrable into automatic processes Manual stroke length
More informationAC 2-wire Inductive Sensors
Tubular, M12 1 AC-sensors are optimized for controllers with alternating current inputs. When maintaining the rated operating current, the sensors can directly control fuses and relays. Housing size M12
More informationAF-300 E11 Adjustable Frequency Drive
AF-300 E11 Adjustable Frequency Drive The AF-300 E11 adjustable frequency drive is GE s new generation of micro drives. GE recognized your need for a high-performance, full-featured compact drive and designed
More informationSeries 7400 Vaneaxial Fans Designs 7410, 7412, 7413 & 7416
Bulletin 7410-3 March 1996 Series 7400 Vaneaxial Fans Designs 7410, 7412, 7413 & 7416 Description Index Series 7400 Vaneaxial Fans The Northern Series 7400 Vaneaxial fan is one of the most rugged axial
More informationModel ED 23 Drying and heating chambers Classic.Line with natural convection
Model ED 23 Drying and heating chambers Classic.Line with natural convection The strengths of a BINDER ED series drying chamber include routine drying and sterilization tasks up to 300 C. Thanks to the
More informationPROCESS HEAT. From LE to LHS: How to benefit from Leister s new generation of air heaters. We know how.
PROCESS HEAT From LE to LHS: How to benefit from Leister s new generation of air heaters. We know how. 3 New LHS air heaters from Leister: Compact and reliable. 1 Compact: Small dimensions for installation
More informationGP-500 SERIES - Low Voltage
M O T O R & G E N E R A T O R P R O T E C T I O N AUTOMATIC INSULATION RESISTANCE TESTERS Meg-Alert is an automatic, in-line insulation resistance tester and monitor with test capabilities from 500 to
More informationSeries 8800 Radial Tip Fans Design 8812
Bulletin 8800-2 October 1996 Series 8800 Radial Tip Fans Design 8812 Description Index Series 8800 Radial Tip Fans The Design 8812 Radial Tip fan is a reliable, highly efficient, heavy duty, rugged fan
More informationCircuit-Breakers for Motor Protection Series 8523/8
> Accessories Auxiliary contacts 1 NC + 1 NO or 2 NC + 2 NO Undervoltage trip Shunt release > Switch operation with knop > Secure switching > Clear switch setting indicator > Different current setting
More information110 Volt AC at 50 Hertz, 120 Volt AC at 60 Hertz. 20 Amp (UL Continuous), 7 Amp (AC-3), 22 Amp (AC-1)
80 South Street 7596-726, TX Nacogdoches Phone: 96-569-79 Fax: 96-560-685 XTCE007B0A PH FVNR 7A IEC Contactor Eaton Corp Catalog Number XTCE007B0A Manufacturer Eaton Corp Description Magnetic Contactor,
More informationJust cool with green: GEA Küba market SP. The new standard for basic refrigeration applications
Just cool with green: GEA Küba market SP The new standard for basic refrigeration applications engineering for a better world GEA Heat Exchangers GEA Küba market SP The new standard for basic refrigeration
More informationModel FP 240 Drying and heating chambers Classic.Line with forced convection and program functions
Model FP 240 Drying and heating chambers Classic.Line with forced convection and program functions A BINDER material test chamber with mechanical convection of the FP series provides reliably short drying
More informationInstruction Manual Model BlockUpconverter
Instruction Manual Model 2115-55 BlockUpconverter June 2009 - Rev. 0 MODEL 2115 UPCONVERTER CROSS TECHNOLOGIES INC. EXT 10MHZ ALARM POWER Data, drawings, and other material contained herein are proprietary
More informationModel KBF 1020 Constant climate chambers with large temperature / humidity range
Model KBF 1020 Constant climate chambers with large temperature / humidity range The BINDER KBF is the specialist for unconditionally reliable stability testing and precise maintenance of constant climate
More informationLC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil
Product datasheet Characteristics LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationN BTU/Hr Watt. N /8000 BTU/Hr. 1758/2344 Watt. N BTU/Hr Watt. Air Conditioners
Spec-00732 F Sealed Enclosure Air Conditioners Sealed Enclosure Air Conditioners SPECTRACOOL Narrow Indoor/Outdoor N43 11000 BTU/Hr. 3223 Watt INDUSTRY STANDARDS N36 / BTU/Hr. / Watt N28 BTU/Hr. Watt UL/cUL
More informationMILLITARY SPECIFICATION SHEET
INCH-POUND MILLITARY SPECIFICATION SHEET 10 November 2000 SUPERSEDING MIL-R-6106/14B 10 March 1989 RELAY, ELECTRIC, PERMANENT DRIVE, 50 AMP, SPDT (DB) DOUBLE MAKE DOUBLE BREAK AUXILIARY CONTACTS (5 AMP),
More informationModel KBF 115 Constant climate chambers with large temperature / humidity range
Model KBF 115 Constant climate chambers with large temperature / humidity range The BINDER KBF is the specialist for unconditionally reliable stability testing and precise maintenance of constant climate
More informationDMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial
DMP 5 Industrial Pressure Transmitter Welded, Dry Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Industrial Pressure Transmitter Nominal pressure from 0... 6 bar up to 0... 600 bar Output
More informationModel KT 53 Cooling incubators with thermoelectric cooling
Model KT 53 Cooling incubators with thermoelectric cooling The KT series combines outstanding performance with impressive energy efficiency and environmental friendliness. The cooled incubators of the
More informationImmersion Pumps HCT (High Chem) sealless EN
Immersion Pumps HCT (High Chem) sealless 1 6004 EN Centrifugal pumps of plastic for a wide variety of industrial fluids Technical data Delivery rate Q max = 120 l/min Delivery head H max = 32 m Temperature
More information1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control
IEC Contactors and Starters. XT Family of Contactors Contactors and Starters Product Description The Eaton XT contactors and starters includes nonreversing and reversing contactors, overload relays and
More informationSelection guide siemens.com/sirius-modular-system
SIRIUS modular system Selection guide siemens.com/sirius-modular-system Everything for the control cabinet: SIRIUS modular system Efficiently combined Advantages at a glance: Load feeders: easy to implement
More informationLinear flow controls VFC Linear flow controls with actuator IFC
Linear flow controls VFC Linear flow controls with actuator Product brochure GB 3 Edition 01.16 Linear relationship between adjustment angle and flow rate Large control ratio of 25:1 Actuators IC 20 or
More informationModel KT 115 Cooling incubators with thermoelectric cooling
Model KT 115 Cooling incubators with thermoelectric cooling The KT series combines outstanding performance with impressive energy efficiency and environmental friendliness. The cooled incubators of the
More informationLC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC
Product datasheet Characteristics LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC Price* : 86.25 GBP Main Range Product name Product or component type Device short name Contactor application Utilisation category
More informationPart-Turn Electric Multi-Turn Electric
Optional 7 Handwheel Available NEMA 4 Enclosure Approvals MAR s Only (Canadian Standard Association) Enclosure NEMA 7 Enclosure Approvals MAR s Only (Canadian Standard Association) Class I, Divisions 1
More informationRevision 1.0 Parts List Minor
Revision.0 www.grindex.com Parts List 803.8 Minor Table of Contents Table of Contents Introduction... Specially approved products... Product Description...3 The data plate...3 Parts... 4 Exploded view...
More informationNessie Coils for VDH and VDHT valves
Data Sheet Nessie Coils for VDH and VDHT valves Introduction The coils for the Danfoss High-Pressure Systems valves are high-performance and reliable coils based on more than 50 years manufacturing of
More informationDC Motors & Controls. DC2 DC Drives for 1/4 thru 2 Hp PMDC and Shunt Wound Motors. 1/4-2 Hp 115/230 VAC 1 Phase 50/60 Hz.
HVAC Farm Duty Brake 200 & 575 Volt & Controls DC 310 DC2 DC Drives for 1/4 thru 2 Hp PMDC and Shunt Wound DC & Controls 1/4-2 Hp 115/ 1 Phase 50/60 Hz. Applications: General purpose industrial use with
More information