Scodix Ultra Foil Station Operator Guide

Size: px
Start display at page:

Download "Scodix Ultra Foil Station Operator Guide"

Transcription

1 Scodix Ultra Foil Station Operator Guide The Scodix Ultra Pro Press with the Scodix Ultra Foil Station (in- line)

2 Important Notice Copyright 2016 Scodix Ltd. All rights reserved. All product names are trademarks of Scodix Ltd. Other names are the property of the respective owners. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system or translated into any language or computer language, in any form or by any means, electronic, mechanical or otherwise without prior written permission of Scodix Ltd. Disclaimer of Warranty Scodix Ltd. has made every effort to ensure the accuracy and relevancy of the material in this document. It is expected that all sections of this document will be read thoroughly and that all information and procedures should be fully understood. However, Scodix Ltd. assumes no responsibility for any errors that may have been included in this document, and reserves the right to make changes to the document without notice. Scodix Ltd. makes no warranty of any kind in regard to this document including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Scodix Ltd. disclaims any responsibility for incidental or consequential damages in connection with the furnishing, performance or use of this document. Parts of this document may be based on hardware or software developed by third-party vendors. Scodix Ltd. disclaims any responsibility for the accuracy of this document with respect to such hardware and software, and assumes no responsibility for incidental or consequential damages arising due to discrepancies between this document and such hardware or software. When the system is operated properly, as specified by Scodix in this and other publications, there is no danger to operators or to equipment. High-voltage power supplies and UV sources are behind protective covers, which should not be removed. Warning labels are attached to each protective cover. Environmental Policy Service personnel are advised that when changing any part of the Scodix Ultra Foil Station, care should be taken to dispose of those parts in the correct manner and, where applicable, they should be recycled. When the lifecycle of parts, such as filters is complete, the product should be disposed of according to the laws and regulations of the local authority. For more detailed information regarding these recommended procedures, please refer to your local or regional Scodix Ltd. Scodix is committed to continuously seek and implement the best possible manufacturing procedures and servicing routines. Part Number: DBK Edition: March 2016 Revision: Rev 02 Compatible with software version: Scodix Ultra Press - V3.1.5 and higher Important Notice Page 2 of 37

3 Table of Contents Important Notice... 2 About this operator guide... 4 Overview... 5 Scodix Ultra Foil Station - Rewind/Unwind Specifications... 5 Foiling process description... 5 Component overview... 6 Components inside the Scodix Ultra Foil Station... 6 Operator Safety Precautions... 6 Scodix Ultra Foil Station Lockout Procedures... 7 To lockout power to the Scodix Ultra Foil Station... 7 To lockout the drive system and energy sources... 8 To lockout the Pneumatic Air System... 8 Safety Information... 8 Safety Notice... 9 Interlocks... 9 Flammable Liquids and Fumes... 9 Material Safety Data Sheets (MSDSs)... 9 Handling Polymer and Flushing Fluid... 9 Disposing of Consumables and Cleaning Materials... 9 Cleaning liquids Handling Polymer Environment Working Environment Illumination Conditions Ventilation Noise Level Scodix Ultra Foil Station Main Control Touch Screen Main Control Touch Screens Running Information Screens Alarm Screens Working with the Scodix Ultra Foil Station Measuring the diameter of the roll of foil, and an empty core Loading a roll of foil Loading an empty core Threading the foil Setting roller type and diameter parameters Setting the Rewind roll diameter parameters Setting the Unwind roll diameter parameters Checking that the new settings are now updated into the memory Passing control back to the Scodix Ultra Press Setting the tension of the Rewind and Unwind rolls Setting the Foil settings in the Job ticket on the Scodix Ultra Press Selecting the Selective Foil area Operating the Scodix Ultra Foil Station Operating in Local mode Starting the Scodix Ultra Foil Station Stopping the Scodix Ultra Foil Station Important Notice Page 3 of 37

4 Routine Maintenance Daily Maintenance Weekly Maintenance Appendix Threading for Cast & Cure (not currently in use) Document History About this operator guide This Operator Guide should be considered as part of the Scodix Ultra Foil Station, should be referred to regularly. A copy of the Operator Guide must be kept with the Scodix Ultra Foil Station at all times. The instructions contained herein will be invalidated should any modification to the Scodix Ultra Foil Station or to the control system be carried out without the approval of the supplier. Scodix reserves the right to amend in any way the contents of this Operator Guide, at any time. All amendments to the contents of the Operator Guide supplied by Scodix must be incorporated in to the text by the end user. It is the end users responsibility to supply the Operator Guide to any subsequent user of the Scodix Ultra Foil Station. The Scodix Ultra Foil Station should only be operated and worked upon by personnel who have been trained and have read and understood the contents of the Operator Guide. The Scodix Ultra Foil Station should only be used within the limits that it was designed for which is contained within the Scodix Ultra Foil Station specification. About this operator guide Page 4 of 37

5 Overview The Scodix Ultra Foil Station is designed to apply cold foil, or cast & cure effects to sheets indexed through the Scodix Ultra Press. (Note, the cast & cure functionality is not currently in use.) Users should not operate or maintain this Scodix Ultra Foil Station until they have been instructed in the correct procedures by qualified personnel, and have read and understood all the safety precautions and operating procedures contained in this Operator Guide. A copy of this Operator Guide should be kept near the Scodix Ultra Foil Station at all times so that it may be referred to without delay. Scodix Ultra Foil Station - Rewind/Unwind Specifications Maximum web width Maximum reel diameter Material Thickness Unwind core sizes 545 mm 300 mm Micron 76 mm Foiling process description The sheet foiling parameters are preloaded into the Scodix Ultra Foil Station prior to the sheet arriving at the foil station. An encoder is fitted to the preceding conveyor to measure the speed of the line. This encoder is used to set the speed of the conveyors in the foiling section. When the sheet transfers to the foiling section it passes under the infeed heater which warms the polymer slightly prior to foiling if required. The sheet travels on the infeed conveyor and is detected by the infeed paper sensors. Activation of these sensors will reset the foiling encoder to zero and increments the sheet counter by one. The foiling encoder is used to determine to position of the sheet at the index nip. Prior to entering the index nip the sheet passes under the infeed air jet which directs the sheet's leading edge towards the nip reducing the effect of sheet curl which can cause paper jams. The sheet then passes through the index nip where the sheet meets the foil. The nip will move up and down when the encoder count synchronizes with the preloaded sheet parameters. When the nip is down foil is attached to the polymer. As the leading edge of the sheet exits the nip it passes under the outfeed air jet, this ensures the foil peels away from the sheet. The sheet then passes under the UV lamp to cure the polymer under the foil. The sheet then passes under the outfeed paper sensor which counts the sheet out, a missing or slow to exit sheet will actuate a paper jam alarm stopping the Scodix Ultra Foil Station. Overview Page 5 of 37

6 Component overview Components inside the Scodix Ultra Foil Station Web break sensor Figure 1: Components inside the Scodix Ultra Foil Station Rewind roller Unwind roller Manual alignment laser beam Heater Cast and cure roller Infeed sheet sensors Infeed airjet adjuster Scodix UV lamp Rewind twitch roller Index nip Unwind twitch roller Operator Safety Precautions To ensure the safety of Scodix Ultra Foil Station operators and maintainers, the safe working practices and precautions (including hazard WARNING and CAUTION notices) in this Operator Guide must be observed at all times. The inclusion of a WARNING notice indicates that a danger exists which would result in injury to or death of a person. The inclusion of a CAUTION notice indicates that a risk exists that could result in the Scodix Ultra Foil Station being damaged. WARNING! Before operating ensure that no unauthorized person is near the Scodix Ultra Foil Station, and that it is safe to proceed. Beware of possible trap points (places where loose clothing, hair, jewelry, etc. may become trapped), between moving parts and between moving parts and fixed parts; or between the web and rolls; or between rolls. WARNING! The Scodix Ultra Foil Station drive and the energy sources lock-out procedure must be implemented before carrying out any set-up, adjustment or maintenance work not requiring the Scodix Ultra Foil Station to be run. See the Scodix Ultra Foil Station Lockout Procedure on page 7. Safety precautions to be observed at all times by operators also include: Operators must ensure that the work area is free from any debris, oil spills or any item that could obstruct clear access to the Scodix Ultra Foil Station. Do not operate the Scodix Ultra Foil Station when the surrounding area is wet, slippery or fouled with web materials. Operators must be familiar with the location of all the Emergency Stop buttons and other Operator Safety Precautions Page 6 of 37

7 safety devices and must check the action of the emergency stop function before operating the Scodix Ultra Foil Station at the beginning of a new shift. At this time, operators must ensure that all Unwind/Rewind shaft support clamps are closed correctly before proceeding All non-essential personnel and unauthorized visitors must be kept at a safe distance (minimum of 1.6m) from the Scodix Ultra Foil Station when preparing to operate it and when it is operating. Do not wear bulky or torn clothing, long sleeves, neckties or jewelry while operating the Scodix Ultra Foil Station. Wear safety shoes and other items at all times. Long hair must be tied back. Ensure all safety guards, covers and doors are correctly in place and are in good condition before starting the Scodix Ultra Foil Station. Do not tamper with fixed guards or reach through, around or behind them. Do not touch any moving part when the Scodix Ultra Foil Station is operating. Do not clean glue, web particles or other material from the Scodix Ultra Foil Station during operation. Do not attempt to operate the Scodix Ultra Foil Station at a rate/capacity other than that for which it is designed. Any faulty, loose or misplaced electrical cables or pneumatic pipes must be reported immediately and only dealt with by authorized engineers. Never use damaged Rewind/Unwind shafts. Safety precautions for maintenance engineers Observe all the safety precautions stated above and. Do not clean, oil or grease, adjust or service any part or assembly while the Scodix Ultra Foil Station is in operation. Do not make adjustments to Scodix Ultra Foil Station parts or assemblies, which are on or near moving parts. Before proceeding with any cleaning, adjustment or service work, ensure that the Scodix Ultra Foil Station drive and the energy sources lock-out procedure has been applied (in which pneumatic and electrical supply main switches are padlocked [isolated] in their OFF positions. (See the Scodix Ultra Foil Station Lockout Procedure on page 7.). If it is essential to operate the Scodix Ultra Foil Station for inspection, servicing or repair purposes, exercise extreme care to avoid any injury caused by exposed, unguarded or moving parts. Never remove safety guards or covers, or open safety doors while the Scodix Ultra Foil Station is in operation. Scodix Ultra Foil Station Lockout Procedures Health and safety regulations dictate that it is mandatory to perform a power lockout procedure, as described in this section, before performing maintenance on any subsystem in the Scodix Ultra Foil Station that has a mechanical or an electrical component. Locking out the Scodix Ultra Foil Station protects the operator or maintenance person from being inadvertently electrocuted. It requires that you either: Install a lockable electrical power energy-isolating device (for example, a fuse box), to prevent activation of the Scodix Ultra Foil Station during service or maintenance procedures. Or, Unplug the Scodix Ultra Foil Station so that the plug is under the exclusive supervision and control of the person performing the service or maintenance. To lockout power to the Scodix Ultra Foil Station The Scodix Ultra Foil Station Electrical supply is isolated from the Scodix Ultra Press. The isolator on the Scodix Ultra Foil Station can be locked off but power will still be present on the incoming terminals. The Main supply is fed from the Scodix Ultra Press. This Mains air supply should be isolated and locked off before any maintenance work is carried out. Operator Safety Precautions Page 7 of 37

8 Note: Every person who is working on the Scodix Ultra Foil Station should have his or her own individual padlock and key. Each person must apply their own pad-lock to lock off the supplies when carrying out maintenance work. These pad-locks should only be removed when it is safe to do so and when the maintenance work is complete. 1. Disconnect the Scodix Ultra Foil Station from all electrical power sources, and turn off the Main Power Supply. 2. Lock the isolator switch in the OFF position to prevent anyone from inadvertently turning on the electricity. 3. Switch off the external Uninterrupted Power Supply (UPS). 4. After the Scodix Ultra Foil Station is turned off, wait 20 seconds for residual stored electrical energy to discharge. To lockout the drive system and energy sources To ensure the safety of personnel and the Scodix Ultra Foil Station during set-up, adjustment or maintenance procedures in which the Scodix Ultra Foil Station is not to be operated, the installation must be isolated from all energy sources (i.e. electrical and pneumatic) before commencing any work. To lockout the Pneumatic Air System The Scodix Ultra Foil Station pneumatic regulator set is mounted on the Pneumatic Panel. The Main air supply is fed from the Scodix Ultra Press. This Mains air supply should be isolated and locked off before any maintenance work is carried out. Safety Information IMPORTANT SAFETY NOTICE: The press uses Scodix PolySENSE Polymer: This polymer may cause eye irritation. This polymer may cause skin irritation after prolonged or repeated contact. Read and practice the safety guidelines as outlined in the Material Safety Data Sheet (MSDS). Print out the MSDS for the polymer, and post it in the work area as required by prevailing law. An excerpt of the MSDS is provided below: Personal Safety: The operator should wear rubber gloves, a protective apron and safety glasses with side shields when handling polymers. Handling Polymer Spills on Surfaces: Observe the following precautions: Ventilate the area. Contain the spill. Cover with absorbent material. Collect spilled material. Clean up residue with lint-free cloth soaked with Ethanol / IPA Place in a closed container. Do not release to waterways or sewer. Incinerate in a permitted hazardous waste incinerator. Handling Spills on a Person: Observe the following precautions: Eye contact: Immediately flush eyes with large amounts of water. Get immediate medical attention. Skin contact: Flush skin with large amounts of water and soap. If irritation persists, get medical attention. Inhalation: Remove person to fresh air. If not breathing, give artificial respiration and get immediate medical attention. If breathing is difficult, get immediate medical attention. Safety Information Page 8 of 37

9 If swallowed: Call a physician immediately. Do not induce vomiting, unless instructed to do so by a physician. Never give anything orally to an unconscious person. Safety Notice The Scodix Ultra Foil Station contains a UV lamp and high-voltage power supplies. The system also has moving parts. There is no danger to persons or equipment when the system is operated in accordance with the directions provided by Scodix in this and other publications. All high-voltage power supplies are located behind protective covers with warning labels attached. Do not remove these protective covers. Interlocks The main hood has an interlock switch. Opening the main hood during operation immediately stops all moving parts. Flammable Liquids and Fumes If you have any questions regarding the safe operation of the Scodix Ultra Foil Station, do not hesitate to contact your local support representative. Material Safety Data Sheets (MSDSs) The MSDS for Scodix PolySENSE can be found in the Scodix web site. The MSDS for other cleaning fluids used for cleaning e.g. Acetone, IPA, PM, alcohol are to be supplied by the chemical vendor. Keep the MSDS readily available in the work area. Read and consult it for your personal protection. Keep the MSDS in a protective plastic cover. Handling Polymer and Flushing Fluid Use only Scodix PolySENSE Polymer and Flushing fluid supplied by Scodix with the Scodix Ultra Foil Station. When handling Scodix PolySENSE Polymer or Flushing fluid, follow these safety practices: Keep the room where the Scodix Ultra Foil Station is situated well ventilated. Clean all spills immediately, and dispose of the used cleaning materials in accordance with local regulations. Do not smoke near the press. Do not allow any ignition sources near the press, such as an open flames, halogen lights, heaters, pilot lights, or stoves. Do not allow sparks (static, electrical, or mechanical), or spark-producing equipment near the press. Disposing of Consumables and Cleaning Materials All used consumables and cleaning materials must be disposed of in accordance with the relevant regulations. Consult your local authorities to determine the correct manner to dispose of the following wastes: Lint-free cleaning cloths Contaminated chemical-resistant gloves Empty coating-material containers NOTE: For disposal of items other than those listed above, contact your local service provider. Safety Information Page 9 of 37

10 Cleaning liquids Adhere to the local regulations regarding the usage of Acetone, Ethanol or IPA. WARNING! Acetone, Ethanol and IPA are extremely flammable liquids. Do not use it near an open flame or sources of electrical sparks. Do not apply acetone to hot surfaces. Handling Polymer The following precautions are mandatory when handling or storing coating materials. It is also mandatory to adhere to the MSDS specifications for each material: Store the Scodix PolySENSE Polymer in a dry and cool location without direct sunlight or heat. Ensure that containers are tightly closed at all times. When a container is damaged, transfer its contents to a dry, clean and suitable container that is sealed tightly. Only trained personnel are permitted to handle Scodix PolySENSE Polymer. Be especially careful while draining the air conditioner drain tank and avoid splashing. A suitable receptacle must be used. Wear safety glasses with side shields, long-sleeve overalls and protective gloves as indicated in MSDS when handling Scodix PolySENSE or any other cleaning fluid. Scodix PolySENSE, Flushing fluid, acetone, IPA, Alcohol and all waste fluids must not be ingested. Use the entire content of the PolySENSE Container into the press tanks. Environment Make sure you have storage space for the Polymer (Ink) and the foil under the following conditions: Store the polymer in an environment below 35 C (95 F). Avoid direct sunlight, UV radiation and strong oxidizers. Keep containers tightly closed in a dry, cool and well-ventilated place. Store in a place that is only accessible to authorized personnel. Keep out of reach of children. Only store polymer in the original HDPE container. Never mix the polymer from one container with that from another container. Do not store near inert gas, such as nitrogen. Keep the container away from oxidizing materials, acids and bases. Working Environment The production area should be reasonably free of dust and other airborne particles. Dust and particles can affect the printing quality. The temperature and humidity of the working environment should be kept within the limits listed in the Media Specifications. Illumination Conditions Do not expose the Scodix Ultra Foil Station to direct sunlight. Ventilation Make sure the production room is adequately ventilated. Noise Level The operator should wear Ear Protection if required. Safety Information Page 10 of 37

11 Scodix Ultra Foil Station Main Control Touch Screen The Scodix Ultra Foil Station is operated remotely by the Scodix Ultra Press. However it can be operated in Local mode through the Main Control Touch Screen, for example when threading the web. Figure 2: Scodix Ultra Foil Station - Main Control Touch Screen Main Control Touch Screen Emergency stop button Emergency Stop Lock-Down Button Pressing the Emergency Stop button brings the Scodix Ultra Foil Station drive and auxiliary functions to a rapid stop, and the button will automatically lock down. When the cause of the emergency condition is cleared, the button must be released by a turning and pull action. E-Stop Reset NOTE: The Emergency Stop control must not be used for normal production stopping of the Scodix Ultra Foil Station. The E-Stop Reset is automatic once the Scodix Ultra Foil Station safety circuit and the Scodix Ultra Press safety circuit are true. The Main Control Touch Screen will indicate if the Emergency Stop is active, in the alarm screens. Main Control Touch Screens The Scodix Ultra Foil Station has a Local and a Remote Main Control Touch Screen. Figure 3: Home Screen - Local Control Home Screen - Remote Control Scodix Ultra Foil Station Main Control Touch Screen Page 11 of 37

12 The home screen provides information about the current mode of operation (top right text in blue). The modes of operation are: Standby Bypass Foiling Cast & Cure Attention Local The home screen allows the operator to access the following screens: Running screens (described below) Sheet info screens (these screen will not be described in this document.) Alarm Screens (described on page 15) Engineering Screen (these screen will not be described in this document.) Local Control screens (described in Working with the on page 16) Tension Screen - allows the operator to quickly change the Unwind or Rewind tension values Running Information Screens Running Information Screen 1 Running screen 1 provides the operator with key information about the machine operating state. MACHINE STATUS This provides information about the Scodix Ultra Foil Station operating state: Emergency stop Safe to run Running Stopping Rewind at maximum diameter Not safe to run Web break Unwind Diameter stop Scodix Ultra Foil Station Main Control Touch Screen Page 12 of 37

13 SCODIX STATE This displays the Scodix Ultra Foil Station state, which was requested by the Scodix Ultra Press. Off Bypass Foiling Cast & Cure Attention Local This status request should match the machine status display in the top right of the screen. REWIND DIAMETER This shows the actual Rewind diameter. When this value reaches a pre-set maximum (set in the Engineering screen), the Scodix Ultra Foil Station will stop on a diameter stop. UNWIND DIAMETER This shows the actual Unwind diameter. When this value reaches a pre-set minimum (set in the Engineering screen), the Scodix Ultra Foil Station will stop on a diameter stop. Navigation buttons Pressing the NEXT button takes the operator to the RUNNING SCREEN 2. Pressing the HOME button returns the operator to the HOME screen. Running Information Screen 2 TOTAL SHEETS ON This displays the count of the number of sheets that have entered the Scodix Ultra Foil Station. The value is incremented each time a sheet passes the infeed sheet detection sensors. The blue reset button resets the SHEETS ON and SHEETS OFF count. TOTAL SHEETS OFF This displays the count of the number of sheets that have exited the Scodix Ultra Foil Station. The value is incremented each time a sheet passes the outfeed sheet detection sensors. ULTRA-POINTER This displays the sheet number which currently being processed by the Scodix Ultra Press. This sheet number will be loaded in the FIFO register. Scodix Ultra Foil Station Main Control Touch Screen Page 13 of 37

14 FOILER POINTER This displays the sheet number which currently being processed by the Scodix Ultra Foil Station. Navigation buttons Pressing the HOME button returns the operator to the HOME screen. Pressing the NEXT button takes the operator to RUNNING SCREEN 3. Pressing the BACK button returns the operator to RUNNING SCREEN 1. Running Information Screen 3 LAMINATING DRIVE SPEED This shows the speed of the Scodix Ultra Foil Station conveyor. FOILER THREADED STATE This shows the status of how the Scodix Ultra Foil Station has been threaded. NO WEB: Scodix Ultra Foil Station thread state not selected. FOIL STATE: Scodix Ultra Foil Station threaded for foiling operation. CAST STATE: (not currently in use) Scodix Ultra Foil Station threaded for cast & cure operation. Navigation buttons Pressing the BACK button returns the operator to RUNNING SCREEN 2. Pressing the HOME button returns the operator to the HOME screen. Scodix Ultra Foil Station Main Control Touch Screen Page 14 of 37

15 Alarm Screens The alarm screen allows the operator to view all active alarms. Alarms that can be displayed are: Machine not safe to run: Scodix Ultra Foil Station unable to run, because the running conditions do not meet the safety conditions. Emergency stop: Emergency stop circuit activated. Ultra Comms Fault: Communication failure between Scodix Ultra Foil Station and the Scodix Ultra Press. Drives Comms faults: Communication error between PLC and Drives. Drives not safe to run: Faulty drives. Encoder Direction: Mismatch between Unwind & Rewind Directions. Web break: Common web break alarm indicating a web break has been detected. Web break sensor 1: Web break 1 sensor activated. Web Break Sensor 2: Web Break 2 sensor activated. Web Break Sensor 3: Web Break 3 sensor activated. Web Break Sensor 4: Web Break 4 senor activated. FIFO Empty: FIFO register is empty. Thread Error: Mismatch between Scodix Ultra Foil Station thread state and selected mode of operation. Machine Guard Open: Scodix Ultra Foil Station cover is open. UV System Alarm: Faulty UV system. PLC fault: Error within PLC. Paper Jam: Indication of paper jam. Foil low warning: Warning that the Unwind roll is low on foil. Unwind Diameter Stop: Unwind roll at minimum diameter. Rewind Diameter Stop: Rewind roll at maximum diameter. Pressing the RESET ALL button resets all alarms, if the alarm is still active it will not reset. Pressing the HOME button returns the operator to the home screen. Scodix Ultra Foil Station Main Control Touch Screen Page 15 of 37

16 Working with the Scodix Ultra Foil Station Measuring the diameter of the roll of foil, and an empty core 1. Measure the diameter of the core of a roll of foil. Figure 4: Measuring the diameter of a roll of foil 2. Measure the diameter of an empty core. Figure 5: Measuring an empty core Working with the Scodix Ultra Foil Station Page 16 of 37

17 Loading a roll of foil Load a roll of foil as follows: 1. Turn the wing-screw to open the Unwind roller support. Figure 6: Opening the roller support 2. Insert the roll of foil, and push it onto the Unwind roller. Working with the Scodix Ultra Foil Station Page 17 of 37

18 3. Close the Unwind roller support, and turn the wing-screw to lock the roller support. Loading an empty core Insert an empty core as follows: 1. Turn the wing-screw to open the Rewind roller support. 2. Insert an empty core, and push it onto the Rewind roller. Working with the Scodix Ultra Foil Station Page 18 of 37

19 3. Close the Rewind roller support, and turn the wing-screw to lock the roller support. 4. Turn on the Manual laser beam, and use it to align the ends of the two cores. If they are not aligned, then push / pull the cores until they align with the laser beam. Manual laser beam Red stripe of light from the laser beam Working with the Scodix Ultra Foil Station Page 19 of 37

20 Threading the foil Thread the foil as follows: 1. Thread the foil under the first roller, and then over the second roller. 2. Continue threading according the blue line in the diagram below: Figure 7: Threading diagram Working with the Scodix Ultra Foil Station Page 20 of 37

21 3. Pull the foil, and tape it to the empty core. Make sure that the foil is tight, and has no slack. 4. Tape the end of the foil to the empty core. Working with the Scodix Ultra Foil Station Page 21 of 37

22 Setting roller type and diameter parameters 1. At the Scodix Ultra Foil Station control panel, press LOCAL. WARNING! The Scodix Ultra Foil Station must not be left unattended when operating in local control mode, because the Scodix Ultra Foil Station does not be communicating with the Scodix Ultra Press, therefore some alarm signals are not monitored by neither the Scodix Ultra Press, nor by the Scodix Ultra Foil Station. 2. Press LOCAL CONTROL. Working with the Scodix Ultra Foil Station Page 22 of 37

23 3. Press THREADING. 4. Press NEXT (1 of 4 times). Figure: Pressing NEXT (1 of 4 times) 5. Press NEXT (2 of 4 times). Figure: Pressing NEXT (2 of 4 times) Working with the Scodix Ultra Foil Station Page 23 of 37

24 6. Press NEXT (3 of 4 times). Figure: Pressing NEXT (3 of 4 times) 7. Press NEXT (4 of 4 times). Figure: Pressing NEXT (4 of 4 times) Setting the Rewind roll diameter parameters 1. Set the Start Diameter of the Rewind roll by pressing on the START DIA value box. Working with the Scodix Ultra Foil Station Page 24 of 37

25 2. Enter the empty core diameter (mm). (This is the empty core diameter value that you measured, see Measuring the diameter of the roll of foil, and an empty core on page 16). 3. Press ENTER. 4. Set the Stop Diameter of the Rewind roll by pressing on the STOP DIA value box. (This is the maximum roll diameter that the Rewinder will allow onto the roll, before stopping.) Working with the Scodix Ultra Foil Station Page 25 of 37

26 5. Enter the STOP DIA diameter. (The default is 180 mm). Press ENTER. 6. The new parameters are displayed (for example 85 mm, and 180 mm). Press NEXT, to open the Unwind Parameters screen. Setting the Unwind roll diameter parameters 1. At the Unwind Parameters screen, set the Start Diameter of the Unwind roll by pressing on the START DIA value box. Figure 8: Unwind Parameters screen Working with the Scodix Ultra Foil Station Page 26 of 37

27 2. Enter the empty core diameter (mm). (This is the empty core diameter value that you measured, see Measuring the diameter of the roll of foil, and an empty core on page 16). Press ENTER. 3. Set the Stop Diameter of the Unwind roll by pressing on the STOP DIA value box. (This is the diameter of the core when it is empty.) 4. Enter the STOP DIA diameter (mm). Press ENTER. Working with the Scodix Ultra Foil Station Page 27 of 37

28 5. Set the Foil Gauge by pressing on the FOIL GAUGE value box. (This is the thickness of the foil see the specifications from the supplier.) 6. Enter the FOIL GAUGE value. Press ENTER. 7. Press NEXT. Checking that the new settings are now updated into the memory The values that you entered in the step above should now be updated into the memory. If not, then do the following: 1. At the Diameter Reset screen, update the Rewind parameters into memory by pressing RESET (under the RW DIA box). Figure 9: Diameter Reset screen Working with the Scodix Ultra Foil Station Page 28 of 37

29 2. Update the Unwind parameters into memory by pressing RESET (under the UW DIA box). 3. Press HOME. Passing control back to the Scodix Ultra Press On the Home screen, press REMOTE, to give control of the Scodix Ultra Foil Station back to the Scodix Ultra Press. The Scodix Ultra Foil Station control panel now shows that it is in the Remote control status: Working with the Scodix Ultra Foil Station Page 29 of 37

30 Setting the tension of the Rewind and Unwind rolls Setting the roll tension correctly prevents the foil from breaking or buckling, and can reduce unnecessary foil wastage. Consider the following when setting the tension: Always set the Unwind tension higher than the Rewind tension, to prevent foil buckling. Higher Unwind tension reduces unnecessary foil wastage. Tension that is too low allows too much blank foil is lost in-between the images. However, higher tension causes more friction, which can cause the web to break, as well as increases resistance to the motor. Set the tension of the Rewind and Unwind rolls as follows: 1. On the Remote Control screen, press TENSION. 2. Set the Rewind and Unwind tension as required, and adjust as necessary. You can set the following basic initial values, and adjust as necessary: Rewind Tension = 2 Unwind Tension = 8 3. Press HOME to exit the screen. Working with the Scodix Ultra Foil Station Page 30 of 37

31 Setting the Foil settings in the Job ticket on the Scodix Ultra Press Foil settings are located in the highlighted areas of the Job Properties window, as shown below. 1. Click on a ripped job in the Job Queue, to open the Job Properties window. Figure 10: Job Properties window showing areas that are relevant to the Scodix Ultra Foil Station settings NOTE: Old jobs that were not ripped with foil options, must be reimported and ripped with foil options. 2. In the Print Quality section, do the following: a. Set the Polymer Type to Polysense 500. NOTE: Only Polysense 500 can be used for foiling. If necessary, switch the Press to Polysense 500, using the Ink Switching procedure. - See the Scodix Ultra Press Operator Guide - Ink Switching section. b. Select the required Print Mode. (This will affect the height of the polymer and amount of polymer used.) Working with the Scodix Ultra Foil Station Page 31 of 37

32 3. In the Pin (LED UV) section, do the following: a. Set the Pin (LED UV) to Auto. (Pinning changes the polymer into a semi-cured state, which stops it from spreading out too much.) b. Set the Pin (LED UV) Power %, the recommended value is between 10 % and 30 %. NOTE: In general, the higher the power, the less the foil adheres to the substrate. However, different foil types have different optimal power settings. 4. In the Scodix Foil section, do the following: a. Click Use Foil. b. Set the Activate (UV power) %, the recommended value is between 40 % and 80 %. Selecting the Selective Foil area 1. Click Selective Foil to select the areas of the image that will receive foil. The Selective Foil window shows one or more potential foiling areas, of 50 mm or more, that were automatically marked with a green line on the right of the preview image. Figure 11: Selective Foil window showing green areas for foiling First foil area - roll engage point First foil area - roll disengage point Second foil area - roll engage point Second foil area - roll disengage point Working with the Scodix Ultra Foil Station Page 32 of 37

33 2. To remove gaps between foil areas, click Mark All Image for the foil area to be continuous. 3. To move the First foil area - roll engage point, enter an Offset distance (mm). 4. To unselect / select a foiling area, click on the green line. Figure 12: Two Foil Areas selected One Foil Area selected Working with the Scodix Ultra Foil Station Page 33 of 37

34 Operating the Scodix Ultra Foil Station The Scodix Ultra Foil Station can be operated in 'foiling' Mode. (Note, there is another mode that is not being used called the 'Cast & Cure Mode'.) Each mode requires the web to be threaded slightly differently, the control of the index nip also changes between each mode. The Scodix Ultra Foil Station has a 'Bypass' mode where all nips are in their disengaged positions and only the Conveyor is running, this mode is used to clear the Ultra & Scodix Ultra Foil Station of any sheets. This mode is selected by the Scodix Ultra Press when required. Operating in Local mode The Scodix Ultra Foil Station has the ability to be operated locally from the Control Touch Screen, this function is tests that the Scodix Ultra Foil Station is functioning correctly and not intended for continuous Scodix Ultra Foil Station operation. Starting the Scodix Ultra Foil Station The Scodix Ultra Foil Station is controlled from the Scodix Ultra Press, when the Scodix Ultra Press is ready to print, a Foiling state signal is sent to the Scodix Ultra Foil Station. The signal will put the Scodix Ultra Foil Station into a foil state. The nip will lower closing the nip to 3mm and start the Laminating drive and Rewind drive. The Laminating drive will be held at zero speed until the Ultra outfeed conveyor starts moving. The laminating drive will then follow the speed of the Ultra Conveyor. The Rewind shaft will rotate with a 10% over speed. When the Scodix Ultra Foil Station Conveyor speed is above 10m/min the UV shutter signal will be activated, when the speed drops below 10m/min the UV open shutter signal is removed. The Scodix Ultra Foil Station will index the index nip as determined by the sheet parameters loaded into the Scodix Ultra Foil Station. Stopping the Scodix Ultra Foil Station Under normal circumstances the Scodix Ultra Press will initiate the off signal to stop the Scodix Ultra Foil Station, when the signal is received the nip roll will raise to the disengaged position and the drives will ramp to zero speed and switch off. As the speed drops below 10m/min the UV shutter signal will be removed ensuring the UV shutter is closed by the time the conveyor speed reaches zero. The foil web only moves through the Scodix Ultra Foil Station when the index nip is down. The foil nip is quickly stopped by a brake when moving to the up position to achieve maximum foil saving. The foil is monitored by web break sensors, so in the event of the foil web breaking the Scodix Ultra Foil Station is stopped quickly. The Scodix Ultra Foil Station can initiate a stop cycle if a problem has occurred within the Scodix Ultra Foil Station via an attention signal to the Scodix Ultra Press these are: a. Unwind diameter stop, (Scodix Ultra Foil Station has run out of foil) b. Paper Jam c. Drive fault d. Not safe to run e. PLC fault. f. Encoder direction mismatch Operating the Scodix Ultra Foil Station Page 34 of 37

35 Routine Maintenance Daily Maintenance Scodix Ultra Foil Station: At the start and finish of each shift, check the Emergency Stop condition and reset if necessary. Check that equipment condition overall is satisfactory and safe for operation. Check the Emergency stop buttons and the Scodix Ultra Foil Station guard. Air system: Check air pressure at Air Set gauge is set to supply 6 bar. Air pressure settings: Check for correct settings at Scodix Ultra Foil Station pressure regulator gauges. At start and finish of each shift: The equipment should be dusted down with a clean soft cloth to remove any dust and dirt, which may have accumulated. Weekly Maintenance Repeat Daily maintenance. Pneumatic system: Check throughout for loose connections and air leaks. Take any necessary action to correct. Rewind airshafts: Check for correct expanding operation and absence of any air leakage. Unwind airshafts: Check for correct expanding operation and absence of any air leakage. Routine Maintenance Page 35 of 37

36 Appendix Threading for Cast & Cure (not currently in use) Cast & Cure is not currently operational. This section has been included for future use. The foil web is threaded through the Scodix Ultra Foil Station as per the figure below. The foil web only moves through the Scodix Ultra Foil Station when the index nip is down. The foil is monitored by web break sensors, so in the event of the foil web breaking the Scodix Ultra Foil Station is stopped quickly. The Scodix Ultra Foil Station also monitors the direction of two idler rolls. If these two rolls are not rotating in the same direction the Scodix Ultra Foil Station will initiate a stop as there is a problem with the foil web. Figure 13: Cast & Cure Web Path 1. Select Local control of the Scodix Ultra Foil Station by pressing LOCAL on the Control Touch Screen. 2. Select the THREADING button. 3. Turn the Unwind and Rewind shaft air supply OFF, this will remove the tension from the shafts. Remove the differential shaft supports. 4. Rotate all the Unwind Differential shaft elements in a clock wise direction and slide the new Unwind reel(s) of foil onto the shaft. Move the foil reel(s) to the desired position on the shaft. Refit the differential shaft support. 5. Rotate all the Rewind Differential shaft elements in an anti-clock wise direction and slide the new Rewind reel(s) onto the shaft. Move the reels to the desired position on the shaft, using the laser alignment position the Rewind reels with its corresponding Unwind reel of foil. Refit the differential shaft support. 6. Press the NEXT button on the Control Touch Screen. WARNING: Before operating the manual control of any nip ensure that no unauthorized person is near the Scodix Ultra Foil Station, and that it is safe to proceed. Beware of trap points between fixed and moving parts. 7. Operate the index nip roll manual control button to the ON position. 8. Thread the foil web as per the figure above. 9. Operate the nip roll manual control button to the ON position. 10. Press the NEXT button on the Control Touch Screen. 11. Turn the Unwind and Rewind Air to the ON position. 12. Press and hold the jog button, the Scodix Ultra Foil Station will jog the foil web through the Scodix Ultra Foil Station. If the Jog button is released the Scodix Ultra Foil Station will stop. Appendix Page 36 of 37

37 13. Press the NEXT button on the Control Touch Screen. 14. Operate the nip roll manual control button to the AUTO position. 15. Operate the index nip roll manual control button to the AUTO position. 16. Press the NEXT button on the Control Touch Screen. 17. Enter the START DIAMETER and STOP DIAMETER of the Rewind reel (pressing the Value will open up a text box to enter new value). 18. Press NEXT on the Control Touch Screen. 19. Enter the START DIAMETER, STOP DIAMETER and FOIL GAUGE of the Unwind roll. 20. Press NEXT on the Control Touch Screen. 21. Press the RESET button to reset the diameters of the Unwind and Rewind Reels, the value will change to the start diameter entered on previous screens. 22. Press NEXT on the Control Touch Screen. 23. Select how the Scodix Ultra Foil Station has been threaded, for cast & Cure web path select Cast & Cure, the text will change to Machine threaded for Cast N Cure. 24. Press the LOCAL button on the Control Touch Screen. 25. Ensure all nip roll control buttons are in the AUTO position. 26. Press NEXT on the Control Touch Screen. 27. Select the UV SYSTEM shutter control to AUTO. 28. Select the HOT AIR BLOWER to AUTO if required. (Temperature and Fan speed adjusted manually.) 29. Select the FANS to AUTO. 30. Press NEXT on the Control Touch Screen. 31. Select the INFEED AIR JET to AUTO if Required (Pressure set manually). 32. Select OUTFEED AIR JET to OFF. 33. Press NEXT on the Control Touch Screen. 34. Select WEB BREAK sensor 1 to 3 to the ON if positioned over the threaded foil. 35. Press NEXT on the Control Touch Screen. 36. Select WEB BREAK sensor 4 to the ON position if positioned over the threaded foil. 37. Press the LOCAL button to return to the local control screen. 38. Ensure Scodix Ultra Foil Station guard is down and no alarms on ALARMS screen. 39. Press the HOME button and select remote control to give control back to the Scodix Ultra Press. 40. The Scodix Ultra Foil Station is now ready to run in Cast N Cure state. Document History Rev Written / updated by Date Approved by Remarks 01 Yossi Bahar Yossi Bahar New Document 02 Yossi Bahar Yossi Bahar Added Setting the tension of the Rewind and Unwind rolls section. Head Office: Scodix Ltd., 13 Amal Street, Park Afek, Rosh Ha ayin , Israel. Tel: (+972) Fax: (972) Document History Page 37 of 37

User Manual. Tensioned Screens. Website: Tel:

User Manual. Tensioned Screens. Website:    Tel: User Manual Tensioned Screens Website: www.luxburgvisual.com Email: support@luxburgvisual.com Tel: 0044 207 237 4842 Table of Contents SAFETY INFORMATION... 3 IMPORTANT SAFETY INSTRUCTION... 3 SETTING

More information

Operation Manual VMS 3.0 Video System

Operation Manual VMS 3.0 Video System Operation Manual VMS 3.0 Video System for the AlterG Anti-Gravity Treadmill 1 This manual covers operation procedures for the following AlterG products: AlterG Video System model VMS 3.0 NOTE: The following

More information

User Guide UD51. Second encoder small option module for Unidrive. Part Number: Issue Number: 5.

User Guide UD51. Second encoder small option module for Unidrive. Part Number: Issue Number: 5. EF User Guide UD51 Second encoder small option module for Unidrive Part Number: 0460-0084-05 Issue Number: 5 www.controltechniques.com Safety Information The option card and its associated drive are intended

More information

PSC300 Operation Manual

PSC300 Operation Manual PSC300 Operation Manual Version 9.10 General information Prior to any attempt to operate this Columbia PSC 300, operator should read and understand the complete operation of the cubing system. It is very

More information

IMPORTANT SAFETY INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS 1. Read, follow and keep these instructions safely. 2. Heed all warnings. 1. Do not use this apparatus near water. 2. Clean only with dry cloth. 3. Do not block any ventilation

More information

Photovoltaic Module Installation Manual (IEC)

Photovoltaic Module Installation Manual (IEC) Phono Solar Technology Co., Ltd. Add: No. 1 Xinghuo Rd., Nanjing Hi-tech Zone, Nanjing, China Tel: +86 25 5863 8000 Fax: +86 25 5863 8009 E-mail: support@phonosolar.com Website: www.phonosolar.com PHONO

More information

Photovoltaic Module Installation Manual (IEC)

Photovoltaic Module Installation Manual (IEC) Phono Solar Technology Co., Ltd. Add: No. 1 Xinghuo Rd., Nanjing Hi-tech Zone, Nanjing, China Tel: +86 25 5863 8000 Fax: +86 25 5863 8009 E-mail: support@phonosolar.com Website: www.phonosolar.com PHONO

More information

SIM 5 series Lamp Kit

SIM 5 series Lamp Kit SIM 5 series Lamp Kit Installation manual R9841842 R59770361/01 04/12/2013 Factory: Barco nv, Simulation Division Noordlaan 5, B-8520 Kuurne Phone: +32 56.36.82.11 Fax: +32 56.36.84.86 Support: www.barco.com/esupport

More information

OPERATION AND MAINTENANCE MANUAL

OPERATION AND MAINTENANCE MANUAL OPERATION AND MAINTENANCE MANUAL SERIAL NUMBER CUSTOMER: SALES REP.: CONTENTS Mixer Installation / Assembly / Dimension Drawings Safety... 1 Customer Service Contact... 1 Initial Inspection... 2 Installation...2

More information

SATRI AMPLIFIER AMP-51R. Owner s Manual

SATRI AMPLIFIER AMP-51R. Owner s Manual SATRI AMPLIFIER AMP-51R Owner s Manual contents SAFETY INSTRUCTIONS 4 INTRODUCTION 6 OVERVIEW (FRONT PANEL) 8 OVERVIEW (REAR PANEL) 9 OVERVIEW (REMOTE CONTROL) 1 1 OPERATION 12 TROUBLESHOOTING 13 SPECIFICATION

More information

USER GUIDE 8-CHANNEL DMX CONTROLLER December 2013 Version 1.0 CHASE / STROBE SPEED FADE SPEED RED GREEN BLUE WHITE AMBER DIMMER INSERT

USER GUIDE 8-CHANNEL DMX CONTROLLER December 2013 Version 1.0 CHASE / STROBE SPEED FADE SPEED RED GREEN BLUE WHITE AMBER DIMMER INSERT 8-CHANNEL DMX CONTROLLER RED GREEN BLUE YELLOW 1 2 3 4 5 6 CYAN ORANGE PURPLE WHITE RED GREEN BLUE WHITE AMBER DIMMER RECORD INSERT DELETE TAP CLEAR MANUAL MUSIC 1 2 3 5 6 7 AUTO CHASE / STROBE SPEED 4

More information

In-Ceiling Electric Motorized Front Projection Screen Evanesce Series. User s Guide

In-Ceiling Electric Motorized Front Projection Screen Evanesce Series. User s Guide In-Ceiling Electric Motorized Front Projection Screen Evanesce Series User s Guide Important Safety & Warning Precautions Make sure to read this user s guide and follow the procedures below. Caution: The

More information

Electronic lubrication control unit

Electronic lubrication control unit Installation instructions Electronic lubrication control unit Model 85307; Single line system Date of issue July 2018 Form number 404773 Version 1 Contents Description....................... 3 Speciications...................

More information

Function Manual SIMATIC HMI TP900. Operator Panel.

Function Manual SIMATIC HMI TP900. Operator Panel. Function Manual SIMATIC HMI TP900 Operator Panel Edition 10/2016 www.siemens.com Introduction 1 Safety notes 2 Medium-voltage converters SIMATIC Description 3 Screens 4 Installing software 5 Function

More information

AUTOMATIC TAPING MACHINE INSTRUCTION MANUAL TAIYO SEIKI CO., LTD.

AUTOMATIC TAPING MACHINE INSTRUCTION MANUAL TAIYO SEIKI CO., LTD. - AUTOMATIC TAPING MACHINE INSTRUCTION MANUAL TAIYO SEIKI CO., LTD. 1 Contents CONTENTS 1. Introduction... 2 1-1. Important safety notice...2 1-2. Precautions for use and installation...2 1-3. Operating

More information

TRF STEP-DOWN TRANSFORMER USER MANUAL

TRF STEP-DOWN TRANSFORMER USER MANUAL TRF STEP-DOWN TRANSFORMER USER MANUA www.ventilation-system.com 2013 ! WARNING The present operation manual consisting of the technical details, operating instructions and technical specification applies

More information

01. Stay safe. Privacy information

01. Stay safe. Privacy information 01. Stay safe In order to enjoy a long and joyful experience with Beam there are a couple of things to keep in mind. Read the following section about safety and regulations before using Beam. Never leave

More information

USER MANUAL. WARNING Read the instructions before using the machine. EN (Original Instruction) / 1704

USER MANUAL. WARNING Read the instructions before using the machine. EN (Original Instruction) / 1704 USER MANUAL European Models American Models 60/100/120 3/4/5 24/40/48 3/4/5 Read the instructions before using the machine. EN (Original Instruction) 9124097 / 1704 KEEP THIS USER MANUAL FOR FUTURE USE

More information

USER MANUAL. 27 Full HD Widescreen LED Monitor L27ADS

USER MANUAL. 27 Full HD Widescreen LED Monitor L27ADS USER MANUAL 27 Full HD Widescreen LED Monitor L27ADS TABLE OF CONTENTS 1 Getting Started 2 Control Panel/ Back Panel 3 On Screen Display 4 Technical Specs 5 Care & Maintenance 6 Troubleshooting 7 Safety

More information

3 Instruction Bulletin 5.41-EU

3 Instruction Bulletin 5.41-EU 3 Instruction Bulletin 5.41-EU Release A-EU, Effective August, 2007 Controltac Graphic Film Series IJ 380 Application of Controltac Graphic Film Series IJ 380 on Substrates with Recesses Introduction 3M

More information

USER MANUAL. 22" Class Slim HD Widescreen Monitor L215DS

USER MANUAL. 22 Class Slim HD Widescreen Monitor L215DS USER MANUAL 22" Class Slim HD Widescreen Monitor L215DS TABLE OF CONTENTS 1 Getting Started Package Includes Installation 2 Control Panel / Back Panel Control Panel Back Panel 3 On Screen Display 4 Technical

More information

Dragonfly Quad. User Manual V1.4. Order code: EQLED101

Dragonfly Quad. User Manual V1.4. Order code: EQLED101 Dragonfly Quad User Manual V1.4 Order code: EQLED101 Safety advice WARNING FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START-UP! Before your initial start-up, please

More information

USER MANUAL. 27 Full HD Widescreen LED Monitor L270E

USER MANUAL. 27 Full HD Widescreen LED Monitor L270E USER MANUAL 27 Full HD Widescreen LED Monitor L270E TABLE OF CONTENTS 1 Getting Started 2 Control Panel/ Back Panel 3 On Screen Display 4 Technical Specs 5 Care & Maintenance 6 Troubleshooting 7 Safety

More information

4-PROJECTOR BAR WITH 3 X 9W LEDS AND 1 X 1W FLASH LED USER GUIDE

4-PROJECTOR BAR WITH 3 X 9W LEDS AND 1 X 1W FLASH LED USER GUIDE 4-PROJECTOR BAR WITH 3 X 9W LEDS AND 1 X 1W FLASH LED USER GUIDE 10482 - Version 1 / 04-2016 English LIVESET - LIVESET - 4-Projector bar with 3 x 9W LEDs and 1 x 1W Flash LED 1 - Safety information Important

More information

DH551C/DH550C/DL550C Double Sided Display User Manual

DH551C/DH550C/DL550C Double Sided Display User Manual DH551C/DH550C/DL550C Double Sided Display User Manual Disclaimer BenQ Corporation makes no representations or warranties, either expressed or implied, with respect to the contents of this document. BenQ

More information

Winmate Communication INC.

Winmate Communication INC. 20.1 Military Grade Display Model: R20L100-RKA2ML User s Manual Winmate Communication INC. May, 2011 1 IMPORTANT SAFETY INSTRUCTIONS Please read these instructions carefully before using the product and

More information

ATTACHING & REMOVING THE BASE

ATTACHING & REMOVING THE BASE TV53DB ATTACHING & REMOVING THE BASE 1. To install or remove the neck, screw in or remove the 4 screws indicated in the picture. 2. To install the base, place the display unit flat on a table. Afterwards

More information

6X3W RGB LEDS PROJECTOR FOR PROFESSIONAL TRUSSES USER GUIDE / Version 1

6X3W RGB LEDS PROJECTOR FOR PROFESSIONAL TRUSSES USER GUIDE / Version 1 6X3W RGB LEDS PROJECTOR FOR PROFESSIONAL TRUSSES USER GUIDE 10364-07-2015 / Version 1 English MINITRUSS-6TCb - 6x3W RGB LEDs projector for professional trusses 2 MINITRUSS-6TCb - 6x3W RGB LEDs projector

More information

28 4K LED monitor. User Manual M284K

28 4K LED monitor. User Manual M284K 28 4K LED monitor User Manual M284K CONTENTS Safety Information... 2 What s included..... 4 Getting Started....... 8 Troubleshooting.... 14 Specification.... 15 2 of 15 SAFETY INFORMATION Read these instructions

More information

PNP300 & PNP350 POP N PLUG SLIM INTERCONNECT BOX USER S GUIDE

PNP300 & PNP350 POP N PLUG SLIM INTERCONNECT BOX USER S GUIDE The is shown above. MANUAL PART NUMBER: 400-0114-004 & PNP350 POP N PLUG SLIM INTERCONNECT BOX USER S GUIDE TABLE OF CONTENTS Page PRECAUTIONS / SAFETY WARNINGS... 2 GENERAL...2 HANDLING...2 CLEANING...2

More information

USER MANUAL Full HD Widescreen LED Monitor L215ADS

USER MANUAL Full HD Widescreen LED Monitor L215ADS USER MANUAL 21.5 Full HD Widescreen LED Monitor L215ADS TABLE OF CONTENTS 1 Getting Started 2 Control Panel/ Back Panel 3 On Screen Display 4 Technical Specs 5 Care & Maintenance 6 Troubleshooting 7 Safety

More information

USER MANUAL Full HD Widescreen LED Monitor L215IPS

USER MANUAL Full HD Widescreen LED Monitor L215IPS USER MANUAL 21.5 Full HD Widescreen LED Monitor L215IPS TABLE OF CONTENTS 1 Getting Started 2 Control Panel/ Back Panel 3 On Screen Display 4 Technical Specs 5 Care & Maintenance 6 Troubleshooting 7 Safety

More information

ALO 030 MKII. 30 Watt DMX LED scanner. User manual

ALO 030 MKII. 30 Watt DMX LED scanner. User manual ALO 030 MKII 30 Watt DMX LED scanner User manual Safety instructions WARNING! Always keep this device away from moisture and rain! Hazardous electrical shocks may occur! WARNING! Only connect this device

More information

Website: Tel: ADDRESS: 6475 Las Positas Rd. Livermore, CA Item No. E5B/E5S Installation Guide

Website:   Tel: ADDRESS: 6475 Las Positas Rd. Livermore, CA Item No. E5B/E5S Installation Guide Website: www.flexispot.com Tel: -855-4-808 ADDRESS: 6475 Las Positas Rd. Livermore, CA 9455 Item No. E5B/E5S Installation Guide Specifications Step Column 3 Max. Weight Capacity 0 Ibs (00 kg) Speed 38mm/s

More information

Register your product and get support at www.philips.com/welcome SWW1890 User manual Contents 1 Important 4 Safety 4 English 2 Your Philips Wireless HD Net Connect 5 What is in the box 5 3 Overview 6

More information

HDCVI Camera User s Manual

HDCVI Camera User s Manual HDCVI Camera User s Manual Version 1.0.2 Table of Contents 1 General Introduction... 1 1.1 Overview... 1 1.2 Features... 1 2 Device Framework... 2 3 Installation... 5 3.1 Installation for Model A... 5

More information

.Power Distribution Center. PD-1. Instruction Manual

.Power Distribution Center. PD-1. Instruction Manual .Power Distribution Center. PD-1 Instruction Manual www.datavideo-tek.com 1 Contents Warnings and Precautions... 3 Warranty... 4 Standard Warranty... 4 Two Year Warranty... 4 Disposal... 4 Packing List...

More information

HEX16 Strip User Manual

HEX16 Strip User Manual User Manual www.showtech.com.au 1 Table of Contents 1. Safety instructions 3 1.1 Overhead rigging.4 1.2 Power Connection..5 1.3 Cleaning and Maintenance..6 2. Menu Navigation..7 3. DMX Allocation..9 4.

More information

SINAMICS G130. dv/dt filter plus Voltage Peak Limiter. Operating Instructions 03/2013 SINAMICS

SINAMICS G130. dv/dt filter plus Voltage Peak Limiter. Operating Instructions 03/2013 SINAMICS SINAMICS G130 Operating Instructions 03/2013 SINAMICS s dv/dt filter plus Voltage Peak Limiter Safety information 1 General 2 SINAMICS SINAMICS G130 Operating Instructions Mechanical installation 3 Electrical

More information

28 & 32 & 40 & 55 & 65 & 84-INCH TFT-LCD 4K MONITOR

28 & 32 & 40 & 55 & 65 & 84-INCH TFT-LCD 4K MONITOR 28 & 32 & 40 & 55 & 65 & 84-INCH TFT-LCD 4K MONITOR INSTRUCTION MANUAL Please read this manual thoroughly before use, and keep it handy for future reference. TABLE OF CONTENTS 1, General information...

More information

PNP300 / PNP300UN / PNP350

PNP300 / PNP300UN / PNP350 DOCUMENT NUMBER 400-0114-003 / UN / PNP350 Pop N Plug Slim INTERCONNECT BOX USER'S GUIDE TABLE OF CONTENTS Page PRECAUTIONS / SAFETY WARNINGS...2 GENERAL...2 INSTALLATION...2 CLEANING...2 ABOUT YOUR /300UN/350...3

More information

Owner s Manual. Backup Monitor System. LCD Monitor & CCD Color Camera

Owner s Manual. Backup Monitor System. LCD Monitor & CCD Color Camera Backup Monitor System LCD Monitor & CCD Color Camera Backup Monitor System Copyright 2003 TMI Products, Inc. All Rights Reserved Corona, CA U.S.A. 060300 Owner s Manual 1493 Bentley Drive Corona, CA 92879

More information

User Instructions. 16 SCB Sync Station.

User Instructions. 16 SCB Sync Station. User Instructions 16 SCB Sync Station Contents Overview... 1 Specifications... 1 Compliance and approvals... 2 Safety instructions... 3 Set up... 4 How to charge multiple devices... 4 How to synchronize

More information

800 Displaying Series Flowmeter

800 Displaying Series Flowmeter TECHNICAL PRODUCT INSTRUCTION SHEET 800 Displaying Series Flowmeter OVERVIEW The principle of operation is very simple. A jet of liquid is directed at a free running Pelton wheel turbine in a specially

More information

LED Thunder S-150 Code 1097

LED Thunder S-150 Code 1097 LED Thunder S-150 Code 1097 User Manual 1 1 SAFETY INSTRUCTIONS This device has left the factory in perfect condition. In order to maintain this condition and to ensure a safe operation, it is absolutely

More information

MSF1000. MSF Radio Time Code Receiver. User Manual Version 1.1. World Time Solutions. World Time Solutions Limited

MSF1000. MSF Radio Time Code Receiver. User Manual Version 1.1. World Time Solutions. World Time Solutions Limited MSF1000 MSF Radio Time Code Receiver User Manual Version 1.1 World Time Solutions World Time Solutions Limited COPYRIGHT 2011-2014 World Time Solutions Limited. All Rights Reserved. All information contained

More information

GPS4000. GPS Time Receiver System. User Manual Version 1.1. World Time Solutions. World Time Solutions Limited

GPS4000. GPS Time Receiver System. User Manual Version 1.1. World Time Solutions. World Time Solutions Limited GPS000 GPS Time Receiver System User Manual Version. World Time Solutions World Time Solutions Limited COPYRIGHT 0-0 World Time Solutions Limited. All Rights Reserved. All information contained within

More information

Elcometer Circular Ball Type. Drying Time Recorder. Operating Instructions

Elcometer Circular Ball Type. Drying Time Recorder. Operating Instructions English Elcometer 5500 Circular Ball Type Drying Time Recorder Operating Instructions English The Elcometer 5500 Circular Ball Type Drying Time Recorder has been tested in accordance with EU Regulations

More information

LED Spot Light User Manual Model LS90 Big Dipper Laser Science And Technology Co., Ltd Please read this manual carefully before operating

LED Spot Light User Manual Model LS90 Big Dipper Laser Science And Technology Co., Ltd Please read this manual carefully before operating LED Spot Light User Manual Model:LS90 Big Dipper Laser Science And Technology Co., Ltd REV: 1.01 Please read this manual carefully before operating Warnings: Please check the package whether any damage

More information

HDCVI Camera User s Manual

HDCVI Camera User s Manual HDCVI Camera User s Manual Version 1.0.0 Table of Contents 1 General Introduction... 1 1.1 Overview... 1 1.2 Features... 1 2 Device Framework... 2 3 Device Cable Structure... 4 4 Device Installation...

More information

Operating Manual (Edition 04/2004) sinamics. Line Reactors SINAMICS G130

Operating Manual (Edition 04/2004) sinamics. Line Reactors SINAMICS G130 Operating Manual (Edition 04/2004) sinamics Line Reactors SINAMICS G130 Contents 1. Safety Information 2 2. General 5 3. Mechanical Installation 6 4. Electrical Installation 8 5. Technical Specifications

More information

Operating Instructions and Parts Manual 24383

Operating Instructions and Parts Manual 24383 Please read and save these instructions. Read through this owner s manual carefully before using product. Protect yourself and others by observing all safety information, warnings, and cautions. Failure

More information

Peak Atlas IT. RJ45 Network Cable Analyser Model UTP05. Designed and manufactured with pride in the UK. User Guide

Peak Atlas IT. RJ45 Network Cable Analyser Model UTP05. Designed and manufactured with pride in the UK. User Guide GB05-7 Peak Atlas IT RJ45 Network Cable Analyser Model UTP05 Designed and manufactured with pride in the UK User Guide Peak Electronic Design Limited 2001/2013 In the interests of development, information

More information

USER MANUAL. 28" 4K Ultra HD Monitor L28TN4K

USER MANUAL. 28 4K Ultra HD Monitor L28TN4K USER MANUAL 28" 4K Ultra HD Monitor L28TN4K TABLE OF CONTENTS 1 Getting Started 2 Control Panel/ Back Panel 3 On Screen Display 4 Technical Specs 5 Care & Maintenance 6 Troubleshooting 7 Safety Info &

More information

Mini LED Pin Spot Light Model: PLS00571

Mini LED Pin Spot Light Model: PLS00571 Mini LED Pin Spot Light Model: PLS00571 1 Please read these instructions carefully before use and retain for future reference. IMPORTANT SAFETY INFORMATION When using electrical appliances basic safety

More information

INSTRUCTION DE SÉCURITÉ SAFETY INSTRUCTION Mandatory as defined in SAPOCO/42 FIRE PREVENTION FOR CABLES, CABLE TRAYS AND CONDUITS

INSTRUCTION DE SÉCURITÉ SAFETY INSTRUCTION Mandatory as defined in SAPOCO/42 FIRE PREVENTION FOR CABLES, CABLE TRAYS AND CONDUITS CERN INSTRUCTION DE SÉCURITÉ SAFETY INSTRUCTION Mandatory as defined in SAPOCO/42 Edms 335813 TIS IS 48 Edited by: TIS/GS Publication Date: June 2001 Original: English FIRE PREVENTION FOR CABLES, CABLE

More information

3 Application Tapes. Premasking and Prespacing Tape for Graphic Films. Instruction Bulletin 4.3 Release UK-K, Effective March 2010

3 Application Tapes. Premasking and Prespacing Tape for Graphic Films. Instruction Bulletin 4.3 Release UK-K, Effective March 2010 Instruction Bulletin 4.3 Release UK-K, Effective March 2010 3 Application Tapes Premasking and Prespacing Tape for Graphic Films Table of Contents Product Description... 1 Product Line... 2 Characteristics...

More information

HDCVI Eyeball Camera Lite

HDCVI Eyeball Camera Lite HDCVI Eyeball Camera Lite User s Manual V1.0.0 Foreword General This user s manual (hereinafter referred to be "the Manual") introduces the functions, installation, and operations of the camera. Safety

More information

INSTALLATION AND OPERATING MANUAL FOR ALL MATSUKO SWITCHBOX MODELS SWB 5 SWB 5P SWB 5P+PG WARNING:

INSTALLATION AND OPERATING MANUAL FOR ALL MATSUKO SWITCHBOX MODELS SWB 5 SWB 5P SWB 5P+PG WARNING: MSB12906121MAN UK English INSTALLATION AND OPERATING MANUAL FOR ALL MATSUKO SWITCHBOX MODELS SWB 5 SWB 5P SWB 5P+PG WARNING: Ensure that the Matsuko Switchbox is switched off at the mains before you attempt

More information

PC-250. SMD Taped Parts Counter Operator s Manual. ISO 9001:2008 Certified. V-TEK, Incorporated 751 Summit Avenue Mankato, MN USA

PC-250. SMD Taped Parts Counter Operator s Manual. ISO 9001:2008 Certified. V-TEK, Incorporated 751 Summit Avenue Mankato, MN USA PC-250 SMD Taped Parts Counter Operator s Manual ISO 9001:2008 Certified V-TEK, Incorporated 751 Summit Avenue Mankato, MN 56001 USA (P) 507-387-2039 (F) 507-387-2257 www.vtekusa.com Dear Customer: All

More information

ivw-fd122 Video Wall Controller MODEL: ivw-fd122 Video Wall Controller Supports 2 x 2 Video Wall Array User Manual Page i Rev. 1.

ivw-fd122 Video Wall Controller MODEL: ivw-fd122 Video Wall Controller Supports 2 x 2 Video Wall Array User Manual Page i Rev. 1. MODEL: ivw-fd122 Video Wall Controller Supports 2 x 2 Video Wall Array User Manual Rev. 1.01 Page i Copyright COPYRIGHT NOTICE The information in this document is subject to change without prior notice

More information

CONTENTS. Table of Figures

CONTENTS. Table of Figures Application Note SXGA Microdisplay Handling Guide (Low Volume) Customer support information: CRL Opto Limited, Dawley Road, Hayes, Middlesex, UB3 1HH. United Kingdom. Tel: +44 (0) 20 8848 6400 Fax: +44

More information

Operating Instructions 07/2007 Edition. SINAMICS G130/G150 Line harmonics filter. sinamics

Operating Instructions 07/2007 Edition. SINAMICS G130/G150 Line harmonics filter. sinamics Operating Instructions 07/2007 Edition SINAMICS G130/G150 Line harmonics filter sinamics s Safety information 1 General 2 SINAMICS SINAMICS G130/G150 Operating Instructions Mechanical installation 3 Electrical

More information

PEGAS 160 T PULSE HF PEGAS 200 T PULSE HF

PEGAS 160 T PULSE HF PEGAS 200 T PULSE HF - 1 - WELDING INVERTER PEGAS 160 T PULSE HF PEGAS 200 T PULSE HF OPERATING MANUAL PEGAS 160-200 T PULSE manual EN 06 -2- CONTENT: 1. INTRODUCTION... 3 2. SAFETY INSTRUCTIONS AND WARNINGS... 4 3. TECHNICAL

More information

/ PAT01 USER MANUAL

/   PAT01 USER MANUAL PONOVO POWER CO., LTD No. 139 Jinghai Third Road, BDA, Beijing, China, 100176 Office TEL. +86 (10) 59089666 E-Mail Website Info@relaytest.com www.relaytest.com / www.ponovo.com.cn PAT01 USER MANUAL VERSION:

More information

LED Spot 300W. Please read this user manual before your operation

LED Spot 300W. Please read this user manual before your operation LED Spot 300W Please read this user manual before your operation 1. Introduction 2. General Guideline 3. Safety Instructions 4. Cleaning and Maintenance 5. Technical Parameters 6. DMX Channels 7. Remark

More information

OPERATOR MANUAL OSD351 FIBRE OPTIC CCTV TRANSMITTER CARD

OPERATOR MANUAL OSD351 FIBRE OPTIC CCTV TRANSMITTER CARD OPERATOR MANUAL OSD351 FIBRE OPTIC CCTV TRANSMITTER CARD OSD351 FIBRE OPTIC CCTV TRANSMITTER CARD Document No:10103701 PAGE 2 C O N T E N T S 1. TECHNICAL SUMMARY...4 1.1 BRIEF DESCRIPTION...4 1.2 TECHNICAL

More information

INSTRUCTION & INSTALLATION GUIDE

INSTRUCTION & INSTALLATION GUIDE Digital electric radiator INSTRUCTION & INSTALLATION GUIDE 2 Introduction harmoni digital electric radiators are programmable with an exclusive electronic temperature programmer and manufactured with quality

More information

Check our knowledge base at

Check our knowledge base at USER MANUAL Check our knowledge base at www.paralinx.net/support Copyright 2015 Paralinx LLC All Rights Reserved TABLE OF CONTENTS 1 Important Notice 10 LCD Screen 2 Safety Instructions 11 Indicators 3

More information

Electrical connection

Electrical connection (I)GSU 14C Ultrasonic Label Fork Dimensioned drawing en 06-2011/12 50109234-01 4mm 12-30 V DC 4 m/s We reserve the right to make changes DS_IGSU_14C_en.fm Ultrasonic forked sensor for universal application

More information

PLL1920M LED LCD Monitor

PLL1920M LED LCD Monitor PLL1920M LED LCD Monitor USER'S GUIDE www.planar.com Content Operation Instructions...1 Safety Precautions...2 First Setup...3 Front View of the Product...4 Rear View of the Product...5 Installation...6

More information

3 Cleaning. 4 Technical data

3 Cleaning. 4 Technical data EXC+ EXC- Sig- SIG+ SEN- SEN+ 2.4 Attaching cable to the analog board Attaching cable of the weighing cell to the system solution Connect the cable to the appropriate terminal strip of the Ex1 system solution

More information

Trusted 40 Channel 120 Vac Digital Input FTA

Trusted 40 Channel 120 Vac Digital Input FTA PD-T8824 Trusted Trusted 40 Channel 120 Vac Digital Input FTA Product Overview The Trusted 40 Channel 120 Vac Digital Input Field Termination Assembly (FTA) T8824 is designed to act as the main interface

More information

DA IN 1-OUT LINE DRIVER WITH EQUALIZATION + AUDIO USER S GUIDE

DA IN 1-OUT LINE DRIVER WITH EQUALIZATION + AUDIO USER S GUIDE MANUAL PART NUMBER: 400-0430-001 1-IN 1-OUT LINE DRIVER WITH UALIZATION + AUDIO USER S GUIDE TABLE OF CONTENTS Page PRECAUTIONS / SAFETY WARNINGS... 2 GENERAL...2 GUIDELINES FOR RACK-MOUNTING...2 INSTALLATION...2

More information

HDCVI Camera User s Manual

HDCVI Camera User s Manual HDCVI Camera User s Manual Version 1.0.3 Table of Contents 1 General Introduction... 1 1.1 Overview... 1 1.2 Features... 1 2 Device Framework... 2 3 Installation... 5 Model A... 5 Model B1 and B2... 6

More information

USER MANUAL Full HD Widescreen LED Monitor L236VA

USER MANUAL Full HD Widescreen LED Monitor L236VA USER MANUAL 23.6 Full HD Widescreen LED Monitor L236VA TABLE OF CONTENTS 1 Getting Started 2 Control Panel/ Back Panel 3 On Screen Display 4 Technical Specs 5 Care & Maintenance 6 Troubleshooting 7 Safety

More information

ER-100 Eurorack 8 Channel Stereo, Transformer Balanced Out Summing Mixer User Manual

ER-100 Eurorack 8 Channel Stereo, Transformer Balanced Out Summing Mixer User Manual ER-100 Eurorack 8 Channel Stereo, Transformer Balanced Out Summing Mixer User Manual Issue 0.1 SAFETY INSTRUCTIONS WARNING Always follow the precautions listed below to avoid any possibility of serious

More information

Electronic Roll Feed (ERF) Registration System

Electronic Roll Feed (ERF) Registration System 3 Electronic Roll Feed (ERF) Registration System Information Folder 9.6 May 2014 Replaces IF 9.6 dated February 2013 Safety Blanking Die Guard: Fabricated guards enclose the blanking die to prevent accidental

More information

3M Cold Shrink QS-III Silicone Rubber Splice Kit 5488A-TOW/WOT

3M Cold Shrink QS-III Silicone Rubber Splice Kit 5488A-TOW/WOT 3M Cold Shrink QS-III Silicone Rubber Splice Kit 5488A-TOW/WOT For Tape Over Wire (TOW) and Wire-Over-Tape (WOT) Shielded Cable For 250 2000 kcmil cable with 650-mil primary insulation thickness Instructions

More information

PL2410W LCD Monitor USER'S GUIDE.

PL2410W LCD Monitor USER'S GUIDE. PL2410W LCD Monitor USER'S GUIDE www.planar.com Content Operation Instructions...1 Safety Precautions...2 First Setup...3 Front View of the Product...4 Rear View of the Product...5 Quick Installation...6

More information

ACCESSORIES MANUAL PART NUMBER: PRODUCT REVISION: 1 TNP100. Tilt N Plug Interconnect Box USER'S GUIDE

ACCESSORIES MANUAL PART NUMBER: PRODUCT REVISION: 1 TNP100. Tilt N Plug Interconnect Box USER'S GUIDE MANUAL PART NUMBER: 400-0091-001 PRODUCT REVISION: 1 TNP100 Tilt N Plug Interconnect Box USER'S GUIDE INTRODUCTION Your purchase of the TNP100 Tilt N Plug Interconnect Box is greatly appreciated. We are

More information

AWT150C/AWT150CS/ AWT151C CCD Camera

AWT150C/AWT150CS/ AWT151C CCD Camera AWT150C/AWT150CS/ AWT151C CCD Camera ISSUED OCTOBER 2018 WARNING Failure to follow all instructions and safety precautions in this manual, in the vehicle and body manufacturers' manuals and on the safety

More information

SmartCrystal Cinema Neo

SmartCrystal Cinema Neo Model VPSP-11100 www.volfoni.com 1 SUMMARY SUMMARY... 2 I. PRODUCT OVERVIEW... 3 II. REQUIREMENTS... 3 III. SMARTCRYSTAL CINEMA NEO FEATURES... 5 A. General specifications... 5 B. Technical specifications...

More information

PLL2210MW LED Monitor

PLL2210MW LED Monitor PLL2210MW LED Monitor USER'S GUIDE www.planar.com Content Operation Instructions...1 Safety Precautions...2 First Setup...3 Front View of the Product...4 Rear View of the Product...5 Quick Installation...6

More information

Operation and Maintenance Guide Electric Needle Scalers

Operation and Maintenance Guide Electric Needle Scalers Operation and Maintenance Guide Electric Needle Scalers Models Covered Model Number ENS100V ENS200V Electric Needle Scaler, 110V-1ph Electric Needle Scaler, 220V-1ph Description IMPA Number 59 12 01 59

More information

PRODUCT SPECIFICATIONS

PRODUCT SPECIFICATIONS FOS Spot 150W 1 PRODUCT SPECIFICATIONS TECHNICAL SPECIFICATION Voltage: 100/240 Volt AC, 50/60 Hz. Power Consumption: 250 Watt. Light Source: 150 Watt LEDs, 7500K. Beam angle: 14. Colors: 8 colors + White

More information

ACCESSORIES MANUAL PART NUMBER: PRODUCT REVISION: 1 PNP202. Interconnect Box USER'S GUIDE

ACCESSORIES MANUAL PART NUMBER: PRODUCT REVISION: 1 PNP202. Interconnect Box USER'S GUIDE MANUAL PART NUMBER: 400-0109-001 PRODUCT REVISION: 1 PNP202 Interconnect Box USER'S GUIDE INTRODUCTION Your purchase of the PNP202 Interconnect Box is greatly appreciated. We are sure you will find it

More information

Electric Wall/Ceiling Projection Screen Saker Plus Series User s Guide

Electric Wall/Ceiling Projection Screen Saker Plus Series User s Guide Electric Wall/Ceiling Projection Screen Saker Plus Series User s Guide Important Safety & Warning Precautions Make sure to read this user s guide and follow the procedures below. Caution: The screen s

More information

Label Applicator HERMA 400

Label Applicator HERMA 400 Label Applicator HERMA 400 Info GB V6.0 / 30.3.07 [ Facts & Data ] R Constructional variant Right-hand or left-hand version, always flexible to use L Power supply / Line voltage Max. power consumption

More information

Operating Instructions

Operating Instructions Model No.: MS0801-E02 Operating Instructions Thanks for purchasing our product. Please be sure to read this instruction manual carefully before using our product. Introduction MS0801-E02 supports to switch

More information

Trusted 40 Channel 120 Vac Digital Input FTA

Trusted 40 Channel 120 Vac Digital Input FTA ICSTT-RM290F-EN-P (PD-T8824) Trusted Product Overview The Trusted 40 Channel 120 Vac Digital Input Field Termination Assembly (FTA) T8824 is designed to act as the main interface between a field device

More information

Index. Index. 1.0 Introduction...2 This Manual Operation Finger Lift Cable Lift Pneumatic Operation...

Index. Index. 1.0 Introduction...2 This Manual Operation Finger Lift Cable Lift Pneumatic Operation... Li nearenc oder s wi t httlout put Us ermanual Index 1.0 Introduction..........................2 This Manual...........................2 2.0 Safety Summary......................3 Terms in this Manual....................3

More information

Basic Vortex Mixer Standard Vortex Mixer Advanced Vortex Mixer Pulsing Vortex Mixer

Basic Vortex Mixer Standard Vortex Mixer Advanced Vortex Mixer Pulsing Vortex Mixer Instruction Manual Manual Basic Vortex Mixer Standard Vortex Mixer Advanced Vortex Mixer Pulsing Vortex Mixer Table of Contents Package Contents............... 1 Warranty............... 1 Installation...............

More information

Spectra Batten (Order code: LEDJ95)

Spectra Batten (Order code: LEDJ95) www.prolight.co.uk Spectra Batten (Order code: LEDJ95) Safety WARNING FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START-UP! CAUTION! Keep this equipment away from rain,

More information

ACCESSORIES MANUAL PART NUMBER: TNP500. Universal Tilt N Plug Interconnect Box USER'S GUIDE

ACCESSORIES MANUAL PART NUMBER: TNP500. Universal Tilt N Plug Interconnect Box USER'S GUIDE MANUAL PART NUMBER: 400-0091-003 TNP500 Universal Tilt N Plug Interconnect Box USER'S GUIDE INTRODUCTION Your purchase of the TNP100 Tilt N Plug Interconnect Box is greatly appreciated. We are sure you

More information

ivw-fd133 Video Wall Controller MODEL: ivw-fd133 Video Wall Controller Supports 3 x 3 and 2 x 2 Video Wall Array User Manual Page i Rev. 1.

ivw-fd133 Video Wall Controller MODEL: ivw-fd133 Video Wall Controller Supports 3 x 3 and 2 x 2 Video Wall Array User Manual Page i Rev. 1. MODEL: ivw-fd133 Video Wall Controller Supports 3 x 3 and 2 x 2 Video Wall Array User Manual Rev. 1.01 Page i Copyright COPYRIGHT NOTICE The information in this document is subject to change without prior

More information

HOME THEATER. Super IR Accessories. Vanco Part Numbers. Technical Support

HOME THEATER. Super IR Accessories. Vanco Part Numbers. Technical Support HOME THEATER Super Accessories Vanco Part Numbers 280703 280720 280721 Technical Support www.vanco1.com info@vanco1.com 800-626-6445 DEAR CUSTOMER Thank you for purchasing this product. For optimum performance

More information

10.4" LCD Monitor with Aluminum Front Bezel YPM1040PHB

10.4 LCD Monitor with Aluminum Front Bezel YPM1040PHB SPECIFICATION FOR APPROVAL M0DEL: 10.4" LCD Monitor with Aluminum Front Bezel YPM1040PHB BASE MODEL Customer's Confirmation Approved by: Reviewed by: Prepared by: Supplier's Confirmation Approved by: Reviewed

More information

CNK JR. SERIES CABLE-NOOK JR. TABLETOP INTERCONNECT BOXES USER'S GUIDE

CNK JR. SERIES CABLE-NOOK JR. TABLETOP INTERCONNECT BOXES USER'S GUIDE MANUAL PART NUMBER: 400-0133-001 PRODUCT REVISION: 0 CNK JR. SERIES CABLE-NOOK JR. TABLETOP INTERCONNECT BOXES USER'S GUIDE TABLE OF CONTENTS Page PRECAUTIONS / SAFETY WARNINGS... 2 GENERAL... 2 INSTALLATION...

More information

LA1500R USER S GUIDE.

LA1500R USER S GUIDE. LA1500R USER S GUIDE www.planar.com The information contained in this document is subject to change without notice. This document contains proprietary information that is protected by copyright. All rights

More information