TRANSMISSION ENGINEERING STANDARD TES-P , Rev. 0 TABLE OF CONTENTS 1.0 SCOPE 2.0 CABLES SPLICES

Size: px
Start display at page:

Download "TRANSMISSION ENGINEERING STANDARD TES-P , Rev. 0 TABLE OF CONTENTS 1.0 SCOPE 2.0 CABLES SPLICES"

Transcription

1

2 1.0 SCOPE TABLE OF CONTENTS 2.0 CABLES SPLICES 2.1 Definitions 2.2 Scope of Specifications and Drawings 2.3 General Requirements 2.4 Routing Cables 2.5 Connectors 2.6 Conductor Connections 2.7 Heat Shrinkable Splices Volts Through 35 kv 2.8 Phasing of Cable Splices 2.9 Cable End Caps 3.0 CABLE TERMINATIONS 3.1 General 3.2 Precautions in Making Cable Terminations 3.3 Locating Cable Terminations 3.4 Grounding of Cable Terminations 3.5 Partial Discharge Measurement 3.6 Elbow Terminations PAGE NO. 2 OF 9

3 1.0 SCOPE This standard has been prepared as a guide for the splicing & termination of insulated cables with copper or aluminum conductor that will be used for 0.6/1, 11, 13.8, 33, 34.5, 69, 110, 115, 132, 230 and 380 kv underground cables circuits in the system of Saudi Electricity Company (SEC) Saudi Arabia. 1.1 General Requirements All splices & terminations shall meet the requirements of applicable Saudi Electricity Company Material Standard Specification (12- TMSS-10), IEEE-48, IEEE-404 and in strict compliance with manufacturer s instructions The cables shall also meet the standards of SASO, AEIC, ICEA, IEC and/or any other internationally recognized organizations The high voltage cable terminations shall be installed in a professional manner with acceptable workmanship. Before commencement of work all cable splicing and terminating personnel shall obtain certification (from manufacturer or SEC) valid for a period of not more than one year from the date of issue stating that the person has been trained and is capable of accomplishing the task All GIS terminations shall be done under manufacturer s supervision and instruction, based on GIS termination drawings and installation instructions which shall be submitted to SEC for review and acceptance prior to starting the termination work. Personnel carrying out the terminations shall posses certificate from mother company and/or by an independent agency valid for a period of not more than one year from the date of issue The cables splicing and terminating operation shall be performed in a manner to mitigate the adverse effects of the environmental conditions specified in 01-TMSS CABLE SPLICES 2.1 Definitions The term "Cable Splice" as used in these specifications refers to all splices, solid taps and branches in insulated power cable as may be made in man holes, hand holes, splice boxes, vaults, tunnels, etc. This term does not apply to splices for pulling into ducts. The various types of cable splices referred to in this section are defined as follows: PAGE NO. 3 OF 9

4 2.2 Scope Straight Splice:- A splice between two cables having the same number of conductors. "Y" Splice:- A splice for connecting one cable to two cables, all of which have the same number of conductors. This section covers various types of cable splices for all types and sizes of insulated cable commonly used by SEC for high and low voltage power transmission. Cable splices, not covered here shall be made according to the cable manufacturer's recommendations and design. 2.3 General In making cable splices, the the splicer and/or terminator must be certified by manufacturer or SEC or an independent agency and shall specifically follow this section and the manufacturer's recommendations for the particular splice and type of cable being installed. Splicing power cables requires great care in the assimilation of manufacturer's instructions, utilizing prescribed materials with proper tools and above all, observing extreme cleanliness in all phases of the splicing operation. The cutting of the cable for splices also requires the observance of exact dimensions - length and depth in the preparation of the cable for the splicing procedure. The operation should be carried out in a proper dust free tent where humidity and temperature are controlled as per manufacturer's recommendations. The removal of the semi-conducting layers over the conductor and the insulation should be executed in a manner prescribed in the manufacturer's instructions for each splice. Similar recognition should be applied in the removal of the conductor, insulation and jacket. Unless otherwise permitted by SEC, all splicing operations shall be conducted in a double walled tent equipped with a positive pressure type air conditioning unit. The air conditioning unit shall be capable of maintaining the relative humidity below 40%. 2.4 Routing Cables Route the cables into their final positions, avoiding sharp bends and allowing the ends to overlap. The overlap for splicing power cable should equal the length of the completed splice. Also, it is desirable to have at least 150 m of straight cable beyond ends of finished splice. PAGE NO. 4 OF 9

5 2.5 Connectors Connectors for use in splicing shall be either compression or thermite welded types in accordance with the manufacturer's specific recommendations Compression connectors shall be suitable for aluminum or copper conductors. All connectors 35 mm 2 and above shall have tapered ends and metal barriers. Tapered ends will ease tape splicing and alleviate stress points on high voltage splices Solder type connectors shall not be used with solid dielectric cables When splicing copper to copper conductors, only copper connector shall be used When splicing aluminum to aluminum, only copper-aluminum or aluminum rated connectors shall be used When splicing copper to aluminum conductors, only copper aluminum rated connectors shall be used. 2.6 Conductor Connections Preparation of Conductors The normal procedure for cleaning exposed bare conductor ends prior to installing connectors is brushing the surface of the conductor with a steel brush until it is clean and bright. When cleaning aluminum conductor for compression connections, it is necessary to apply an SEC approved inhibitor compound to the exposed conductors immediately after the wire brushings. The inhibitor compound will prevent the formation of a non-conductive film of oxide on the conductor surface, which would otherwise form as a result of the chemical reaction between the aluminum surface and air Application of Compression Connectors Care shall be taken always to select the recommended compression die for pressing the joint connector. It shall be installed in strict compliance with manufacturer's instructions for applying compression connectors Preparation of Cable Joint Surfaces After the cable joint connector is installed and prior to applying the insulation tape, or heat shrink material, the surfaces of the insulation and insulation shield must be thoroughly cleaned with a SEC approved cleaning fluid. The use of benzine, or gasoline, for this purpose, is not permitted. PAGE NO. 5 OF 9

6 2.7 Heat Shrinkable Sleeve Heat shrinkable polyethylene provides a recommended method for insulating underground splices for XLPE cables (600 V to 35 kv). If the manufacturer's splice kit does not include a heat shrinkable sleeve to protect the concentric neutral wires against corrosion, then one shall be installed. 2.8 Phasing of Cable Splices When the cable splices are installed for the purpose of circuit expansion or repair, the cables to be spliced shall be identified and labeled to correspond with phase indentification at the source side of the cable termination. Splicing of the cables in accordance with proper phase identification will eliminate the possibility of the splice introducing an out-of-phase condition in the circuit. 2.9 Cable End Caps During the period that cables have been placed in ducts or trenches, and are to be spliced at a later time, the cable ends are to be sealed to eliminate moisture entering and corroding the cable conductor. Heat shrinkable caps, shall be utilized and installed on open ends of the cables in order to maintain the integrity of the cable Partial Discharge Test Partial discharge measurements shall be carried out for high voltage cable 230 kv & 380 kv at site after completion of splicing/jointing of the cable to detect the weak points. The tests shall be carried out preferably during the HV test or immediately thereafter. 3.0 CABLE TERMINATIONS 3.1 General Definitions The term "Cable Termination" as used in this Section refers to all terminations of insulated power cable in order to effect an electrical connection to the cable conductor. In its simplest form, a cable termination may be formed by attaching a suitable terminal lug to the end of a cable conductor. For insulated power cable, however, it is necessary to remove a section of the outer jacket and shielding (if applicable), to seal the cable end against the entrance of moisture, as well as provide a suitable electrical termination of the cable insulation shield by means of a stress cone. The method of sealing the cable end varies with the style of cable termination. PAGE NO. 6 OF 9

7 3.1.2 Taped Termination A taped cable termination is one in which the cable end is sealed by the application of suitable insulating tape. Taped terminations of power cables over 5 kv shall require the construction of a stress cone by building up the proper shape through consecutive layers of tape Premolded and Molded Terminations A premolded termination may be one of several types of slip on terminations constructed of rubber like synthetic materials or a combination of plastics and polymers. Terminations in this category include skirted one-piece terminations with varying creep distances, or elbow type of separable connections. The application of premolded and molded terminations shall be performed in strict compliance with the manufacturer's installation procedures Heat Shrink Terminations Heat shrink irradiated polyethylene is used to control terminal stress and provide a means of terminating 15 kv, 35 kv, 69 kv, 110kV, 115 kv, 132 kv, 230 kv and 380 kv cables, indoor and outdoor. The application of heat shrink irradiated polyethylene shall be performed in strict compliance with the manufacturer's installation procedures Porcelain Terminations Indoor and outdoor porcelain terminations are used for kv rated cables, and shall be installed in strict compliance with the manufacturer's procedures SF6 Gas-Immersed Terminations SF6 Gas-Immersed terminations are used up to 380 kv rated cables, and shall be installed in strict compliance with the manufacturer's procedures Terminal Lugs Terminal lugs used for all cable terminations must be selected to insure the compatibility of the metal to metal contact. Where cables with aluminum conductors are to be terminated on copper bus, such as transformers or switchgear or on overhead copper line hardware, the terminal lug shall be rated copperaluminum. An oxide inhibitor PAGE NO. 7 OF 9

8 shall be applied to the aluminum conductor prior to compressing the terminal lug Leakage Distance For outdoor terminations, the leakage distance shall be a minimum of 40 mm/kv line-to-line and 50 mm/kv near the coastel area (preferably with High Voltage Insulator Coating (SYLGARD) for coastal/polluted areas). 3.2 Precautions in Making Cable Terminations In making cable terminations, the splicer and/or terminator must be certified by an independent agency and shall specifically follow the specifications, details, dimensions given on the manufacturer's drawings for the particular termination and type of cable being installed. Extreme care shall be taken in every step from start to finish to keep the cable termination free from moisture, dirt, particles of metal and air pockets. To accomplish this, the technician's hands, tools, containers and supplies must be kept clean, dry and free from foreign matter at all times. Do not expose unpacked premolded insulating materials to the atmosphere for more time than absolutely necessary (as suggested by the manufacturer). After the cable insulation has been exposed by removal of any section of the outer covering, operations should be continued without interruption until the cable termination is complete. Should it be necessary to leave an incomplete cable termination overnight, the exposed cable insulation shall be protected by a carefully applied covering of tape of the final type to be applied to the termination and, in damp locations, this tape shall be covered by a waterproof rubber or plastic tape. Suitable protection (depending on moisture and dirt conditions and the voltage of the termination being made up) shall also be applied to exposed insulation when terminating is interrupted for eating time or for necessary tests. The permanent storage of cable termination shall be strictly as per manufacturer recommendations 3.3 Locating Cable Terminations Locating Terminations Cable terminations are frequently attached directly to the equipment terminals, buses or other conductors. This application determines to an appreciable extent, the location of the termination. However, there may be some choice with regards to the direction from which the cable approaches the termination. The cable shall be so arranged as to permit locating the last cable support close to the termination. This will avoid putting undue strains on the equipment terminals or the PAGE NO. 8 OF 9

9 terminal lugs on the cable. Usually, such terminal supports shall be located mm from the equipment terminals. Terminal supports shall be so located that no sharp edges are made on the cable and no bend occurs in the taped portion of the cable termination. 3.4 Grounding of Cable Terminations General Metal parts of terminating devices, concentric neutral copper, tinsel braid or other metallic shielding on stress cones in cable terminations shall be effectively grounded to the system ground. These various components usually are bonded together within the cable termination so that a single grounding connection serves to ground the complete termination. However, precautions must be taken to make sure that all parts of a termination requiring grounding are properly connected together. An exception is when, on occasion, the open end of a single point grounded section of circuit is terminated. Special provisions will be required to isolate the cable shield or concentric neutral from the ground potential of metal parts of the terminating rack or device. 3.5 Partial Discharge Measurement Partial discharge measurements shall be carried out for high voltage cable 230 kv & 380 kv at site after completion of termination of the cable to detect the weak points. The tests shall be carried out preferably during the HV test or immediately thereafter. 3.6 Elbow Terminations When specified by the Design Engineer, elbow type separable connector terminations may be used to terminate 15 kv and 35 kv rated cables to compartment type padmounted transformer or padmounted switching cubicles All elbow terminations shall be rated 200 amperes for load break service and 600 amperes for no-load break services The elbow terminations shall be provided with a capacitive test point The application of elbow terminations shall be performed in strict accordance with the manufacturer's installation procedures All elbows shall comply with IEEE Standard No PAGE NO. 9 OF 9

SECTION MEDIUM VOLTAGE CABLE INSTALLATION. 1. Section Underground Ducts and Manholes.

SECTION MEDIUM VOLTAGE CABLE INSTALLATION. 1. Section Underground Ducts and Manholes. SECTION 33 71 49.23 MEDIUM VOLTAGE CABLE INSTALLATION PART 1 GENERAL 1.1 SCOPE A. Work included in this Section: Medium Voltage Cable (4 kv and 12 kv) Installation and Termination. Removal and return of

More information

Student Services & Classroom Addition

Student Services & Classroom Addition SECTION 260513 - MEDIUM-VOLTAGE CABLES PART 1 - GENERAL 1.1 SUMMARY A. Section includes cables and related cable splices, terminations, and accessories for mediumvoltage (2001 to 35,000 V) electrical distribution

More information

TERMINATIONS AND JOINTS FOR XLPE-INSULATED kv MEDIUM VOLTAGE CABLES

TERMINATIONS AND JOINTS FOR XLPE-INSULATED kv MEDIUM VOLTAGE CABLES Accessories TERMINATIONS AND JOINTS FOR XLPE-INSULATED 12 36 kv MEDIUM VOLTAGE CABLES Cable Systems, Cables and Accessories Test values for terminations 1) Testing to DIN VDE 0278-629-1 (Testing methods

More information

HIGH VOLTAGE CABLE ACCESSORIES - Application, Design, Installation, Testing - Ivan Jovanovic G&W Electric Company

HIGH VOLTAGE CABLE ACCESSORIES - Application, Design, Installation, Testing - Ivan Jovanovic G&W Electric Company HIGH VOLTAGE CABLE ACCESSORIES - Application, Design, Installation, Testing - Ivan Jovanovic G&W Electric Company 1 Year 1905 First detachable porcelain pothead for 4 kv systems Year 2015 Terminations

More information

STRAIGHT TWO WAY JOINT3/C, PAPER INSULATED, SHIELDED, LEAD COVERED CABLE. Revised: October 10, 2008 Revised By: SGL Approved By: RHS SPLICES

STRAIGHT TWO WAY JOINT3/C, PAPER INSULATED, SHIELDED, LEAD COVERED CABLE. Revised: October 10, 2008 Revised By: SGL Approved By: RHS SPLICES STRAIGHT TWO WAY JOINT3/C, PAPER INSULATED, SHIELDED, LEAD COVERED CABLE I. INSTALLATION INSTRUCTIONS I.1. PRECAUTIONS: I.1.1. Expansion bends must be made in the cables to allow for cable movement while

More information

3M Cold Shrink Splice Kit QS-III 5416A

3M Cold Shrink Splice Kit QS-III 5416A 3M Cold Shrink Splice Kit QS-III 5416A for Jacketed Concentric Neutral (JCN) and Concentric Neutral Cable Instructions IEEE Std. 404 15 kv Class 150 kv BIL CAUTION Working around energized systems may

More information

F CAUTION. Jacketed Concentric Neutral (JCN) Cable. Concentric Neutral (CN) Cable. IEEE Std. No. 48 Class 1 Termination 15 kv Class 110 kv BIL

F CAUTION. Jacketed Concentric Neutral (JCN) Cable. Concentric Neutral (CN) Cable. IEEE Std. No. 48 Class 1 Termination 15 kv Class 110 kv BIL 3M Cold Shrink QT-III Silicone Rubber Skirted Termination Kit With High-K Stress Relief 7642-S-2 For Jacketed Concentric Neutral (JCN) and Concentric Neutral (CN) Cable Instructions IEEE Std. No. 48 Class

More information

EE028: Practical High Voltage Cable Jointing and Termination

EE028: Practical High Voltage Cable Jointing and Termination EE028: Practical High Voltage Cable Jointing and Termination EE028 Rev.001 CMCT COURSE OUTLINE Page 1 of 5 Training Description: The range of voltage and capacity of power transmitted through cables is

More information

3M Cold Shrink Splice Kit QS-III 5515A

3M Cold Shrink Splice Kit QS-III 5515A 3M Cold Shrink Splice Kit QS-III 5515A for UniShield, Wire Shielded, Longitudinally Corrugated (LC), and Tape Shielded (Ribbon Shielded) Cable or Transitions to Concentric Neutral (CN)/Jacketed Concentric

More information

SPECIAL SPECIFICATION 6559 Telecommunication Cable

SPECIAL SPECIFICATION 6559 Telecommunication Cable 2004 Specifications CSJ 0015-09-147, etc. SPECIAL SPECIFICATION 6559 Telecommunication Cable 1. Description. This specification governs the materials, installation, termination, splicing, testing, training,

More information

COOPER POWER SERIES. 600 A 15/25 kv class DT625 T-body installation and cable preparation instructions. Deadbreak Apparatus Connectors MN650017EN

COOPER POWER SERIES. 600 A 15/25 kv class DT625 T-body installation and cable preparation instructions. Deadbreak Apparatus Connectors MN650017EN Deadbreak Apparatus Connectors MN650017EN Effective January 2016 Supersedes S600-46-2 July 2014 COOPER POWER SERIES 600 A 15/25 kv class DT625 T-body installation and cable preparation instructions DISCLAIMER

More information

Cable installation guidelines

Cable installation guidelines The Quality Connection Cable installation guidelines Business Unit Industrial Projects 2 Cable installation guidelines www.leoni-industrial-projects.com GENERAL Installation methods Many different methods

More information

SPECIAL SPECIFICATION 8540 Telecommunication Cable

SPECIAL SPECIFICATION 8540 Telecommunication Cable 2004 Specifications CSJ 0914-00-307 & CSJ 0914-25-003 SPECIAL SPECIFICATION 8540 Telecommunication Cable 1. Description. This specification governs the materials, installation, termination, splicing, testing,

More information

220KV EHV NETWORK AT RELIANCE JAMNAGAR REFINERY COMPLEX

220KV EHV NETWORK AT RELIANCE JAMNAGAR REFINERY COMPLEX 220KV EHV NETWORK AT RELIANCE JAMNAGAR REFINERY COMPLEX JAMNAGAR 220KV CABLE NETWORK: 2 2. DESIGN 2A. NETWORK: 220 KV NETWORK DESIGN IS DESIGNED WITH 100% REDUNDANCY FROM 220 KV BUS TO LOAD. THIS IS ACHIEVED

More information

3M Cold Shrink QS4 Integrated Splice Kit QS4-15JCN

3M Cold Shrink QS4 Integrated Splice Kit QS4-15JCN 3M Cold Shrink QS4 Integrated Splice Kit QS4-15JCN-500-1000 for Jacketed Concentric Neutral (JCN) and Flat Strap Neutral Cable Instructions IEEE Std. 404 15 kv Class 150 kv BIL F CAUTION Working around

More information

3M Cold Shrink QS-III Silicone Rubber Splice Kit 5488A-TOW/WOT

3M Cold Shrink QS-III Silicone Rubber Splice Kit 5488A-TOW/WOT 3M Cold Shrink QS-III Silicone Rubber Splice Kit 5488A-TOW/WOT For Tape Over Wire (TOW) and Wire-Over-Tape (WOT) Shielded Cable For 250 2000 kcmil cable with 650-mil primary insulation thickness Instructions

More information

3M Cold Shrink Splice Kit QS-III 5514A

3M Cold Shrink Splice Kit QS-III 5514A 3M Cold Shrink Splice Kit QS-III 5514A for UniShield, Wire Shielded, Longitudinally Corrugated (LC), and Tape Shielded (Ribbon Shielded) Cable or Transitions to Concentric Neutral (CN)/Jacketed Concentric

More information

2016 Cable Splicing Courses

2016 Cable Splicing Courses 206 Cable Splicing Courses The electrical training ALLIANCE will be offering medium voltage (2,00-35,000 volts) cable splicing classes at several different locations in 206. Module I, of the cable splicing

More information

3M Cold Shrink QS-III Splice Kit 5467A(S)-WF

3M Cold Shrink QS-III Splice Kit 5467A(S)-WF 3M Cold Shrink QS-III Splice Kit 5467A(S)-WF for Jacketed Concentric Neutral (JCN) Cable Instructions IEEE Std. 404 35 kv Class 250 kv BIL F CAUTION Working around energized systems may cause serious injury

More information

3M Cold Shrink QS4 Integrated Splice Kit QS4-15JCN-4/0-500

3M Cold Shrink QS4 Integrated Splice Kit QS4-15JCN-4/0-500 3M Cold Shrink QS4 Integrated Splice Kit QS4-15JCN-4/0-500 for Jacketed Concentric Neutral (JCN) and Flat Strap Neutral Cable Instructions IEEE Std. 404 15 kv Class 150 kv BIL CAUTION Working around energized

More information

DOME OPTIC SPLICE CLOSURE

DOME OPTIC SPLICE CLOSURE FIBER OPTIC SPIICE CLOSURE GJS-JKDH1001-120 BOX DIMENSION: W=140mm H=340mm Weight = 1.80 kgs Outer Internal structure Fuse fiber disc Type sealing ring Plastic hoop base Pole Mount Pole Mount 1 1. product

More information

Public Works Division Lighting District Fiber Optic Specifications April 2009

Public Works Division Lighting District Fiber Optic Specifications April 2009 Public Works Division Lighting District Fiber Optic Specifications April 2009 7000 Florida Street Punta Gorda, Florida 33950 Tele: 941.575.3600 Fax : 941.637.9265 www.charlottecountyfl.com/publicworks

More information

ECONOMICAL 36 kv CABLE SYSTEM FOR THE BELGIAN NETWORK

ECONOMICAL 36 kv CABLE SYSTEM FOR THE BELGIAN NETWORK ECONOMICAL 36 kv CABLE SYSTEM FOR THE BELGIAN NETWORK J. Becker NEXANS BENELUX S.A. F. Musique ELECTRABEL S.A. ABSTRACT In order to tackle the deregulated market with confidence and in a realistic way,

More information

PEM1124ENG ENGLISH. STK TERMINATION KIT FOR PLASTIC CABLE WITHOUT ARMOURING 1 kv STKR TERMINATION KIT FOR PLASTIC CABLE WITH ARMOURING 1 kv

PEM1124ENG ENGLISH. STK TERMINATION KIT FOR PLASTIC CABLE WITHOUT ARMOURING 1 kv STKR TERMINATION KIT FOR PLASTIC CABLE WITH ARMOURING 1 kv INSTALLATION INSTRUCTION PEM1124ENG 2010-05 STK TERMINATION KIT FOR PLASTIC CABLE WITHOUT ARMOURING 1 kv STKR TERMINATION KIT FOR PLASTIC CABLE WITH ARMOURING 1 kv ENGLISH 4 CORE 3+1 CORE 2/8 PEM1124ENG

More information

Quick Term III. 3M Cold Shrink 3 Core Indoor Termination. 3.3 kv mm 2

Quick Term III. 3M Cold Shrink 3 Core Indoor Termination. 3.3 kv mm 2 Quick Term III 3M Cold Shrink 3 Core Indoor Termination Instruction Sheet All dimensions shown are mm unless otherwise stated Kit Contents 3 QT-III Termination Assembly 1 Cold Shrink Breakout Boot 3 Phase

More information

Industrial Loadbreak Elbow

Industrial Loadbreak Elbow Industrial Loadbreak Elbow 200 A 5, 8, and 15 kvclass 5810 Series Installation Instructions 1.0 General The 3M Industrial Loadbreak Elbow connector is a fullyshielded and insulated plug-in termination

More information

3M Super 23 Electrical Tape

3M Super 23 Electrical Tape WEATHERPROOFING S CHEMICALS ET 3M SUPER 23 Features: Premium all-weather black electrical tape Remains conformable at -18 C /0 F 7mm thickness UV resistant Part # Size ET 3M Super 23 19mm x 9.15m WEATHERPROOFING

More information

Cold Shrink Three-Conductor Splice Kit QS-III for use on Armor and Non-Armor Cables Instructions IEEE Std kv Class 250 kv BIL

Cold Shrink Three-Conductor Splice Kit QS-III for use on Armor and Non-Armor Cables Instructions IEEE Std kv Class 250 kv BIL Cold Shrink Three-Conductor Splice Kit QS-III for use on Armor and Non-Armor Cables Instructions IEEE Std. 404 35 kv Class 250 kv BIL Kit Number 5798A-MT Cable Range Requirements Cable Insulation O.D.

More information

Cold Shrink Silicone Rubber Termination QT-II

Cold Shrink Silicone Rubber Termination QT-II 3 Cold Shrink Silicone Rubber Termination QT-II Instructions IEEE Std. No. 48-1990 Class 1 Termination 15 Class 110 kv BIL Kit Contents: 1 Hi-K Silicone Rubber Termination 2 Scotch Silicone Rubber Tape

More information

PEM1126ENG ENGLISH STPKR. TERMINATION KIT FOR PAPER CABLE WITH LEAD SHEATH 1 kv INSTALLATION INSTRUCTION

PEM1126ENG ENGLISH STPKR. TERMINATION KIT FOR PAPER CABLE WITH LEAD SHEATH 1 kv INSTALLATION INSTRUCTION INSTALLATION INSTRUCTION PEM1126ENG 2010-05 TERMINATION KIT FOR PAPER CABLE WITH LEAD SHEATH 1 kv ENGLISH 2/6 PEM1126ENG 2010-05 GENERAL INFORMATION - Check that the kit is suitable for the cable type.

More information

3 Cold Shrink Products

3 Cold Shrink Products 3 Cold Shrink Products Low Voltage Splices 0-600V (1000V rated) 279 Cold Shrink Splices (0-1000V) 279 Cold Splicing Products 279 Resin Splices 0-600V (1000V rated) 281 Resin 284 3M 8420 and 8430 Series

More information

UFGS (August 2010) UNIFIED FACILITIES GUIDE SPECIFICATIONS

UFGS (August 2010) UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-26 05 13.00 40 (November 2013) ----------------------------------- Preparing Activity: NASA Superseding UFGS-26 05 13.00 40 (August 2010) UNIFIED FACILITIES GUIDE SPECIFICATIONS

More information

TRANSMISSION ENGINEERING STANDARD TES-P , Rev. 0 TABLE OF CONTENTS 1.0 PURPOSE 2.0 SCOPE 3.0 CODES, STANDARDS AND REFERENCES

TRANSMISSION ENGINEERING STANDARD TES-P , Rev. 0 TABLE OF CONTENTS 1.0 PURPOSE 2.0 SCOPE 3.0 CODES, STANDARDS AND REFERENCES TABLE OF CONTENTS 1.0 PURPOSE 2.0 SCOPE 3.0 CODES, STANDARDS AND REFERENCES 4.0 ORDER OF PRECEDENCE 5.0 SYSTEM PARAMETERS 5.1 Frequency 5.2 System Voltage 5.3 Short Circuit Rating 5.4 Insulation Levels

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-26 05 13.00 40 (November 2016) ----------------------------------- Preparing Activity: NASA Superseding UFGS-26 05 13.00 40 (November 2013) UNIFIED FACILITIES GUIDE SPECIFICATIONS

More information

ELECTRICAL SAFETY INSPECTION REPORT

ELECTRICAL SAFETY INSPECTION REPORT ELECTRICAL SAFETY INSPECTION REPORT A PLUS INDUSTRIES LIMITED. Plot-28, Milk Vita Rd., Section-07, Mirpur, Dhaka Factory List: 1. A Plus Industries Ltd. Inspected by: Yoon Report Generated by: Nezar Inspected

More information

3M Cold Shrink QS4 Integrated Splice Kit QS4-15JCN-2-4/0

3M Cold Shrink QS4 Integrated Splice Kit QS4-15JCN-2-4/0 3M Cold Shrink QS4 Integrated Splice Kit QS4-15JCN-2-4/0 for Jacketed Concentric Neutral (JCN) and Flat Strap Neutral Cable Instructions IEEE Std. 404 15 kv Class 150 kv BIL F CAUTION Working around energized

More information

3M Cold Shrink QT-III Silicone Rubber Skirted Termination Kit

3M Cold Shrink QT-III Silicone Rubber Skirted Termination Kit 3M Cold Shrink QT-III Silicone Rubber Skirted Termination Kit With High-K Stress Relief For Jacketed Concentric Neutral (JCN) Cable and Concentric Neutral (CN) Cable 7652-S-4, 7652-S-4 (L), 7653-S-4, 7654-S-4,

More information

Aging test: integrated vs. non-integrated splices shield continuity systems.

Aging test: integrated vs. non-integrated splices shield continuity systems. Aging test: integrated vs. non-integrated splices shield continuity systems. George Fofeldea Power Engineer, 3M Canada November 2018 Abstract To maximize long-term splice performance, the implications

More information

3M Cold Shrink QS4 Integrated Splice Kit QS4-35TS

3M Cold Shrink QS4 Integrated Splice Kit QS4-35TS 3M Cold Shrink QS4 Integrated Splice Kit QS4-35TS-350-1000 for Tape Shield, Wire Shield, UniShield, and Longitudinally Corrugated (LC) Cable Instructions IEEE Std. 404 35 kv Class 250 kv BIL F CAUTION

More information

TFT-150R-G. Tape Shield Cable (page 2) Suggested Installation Equipment (not supplied with kit) Wire Shield Cable (page 7)

TFT-150R-G. Tape Shield Cable (page 2) Suggested Installation Equipment (not supplied with kit) Wire Shield Cable (page 7) TFT-150R-G 5-15kV Cold Applied Indoor (5-8kV Indoor and Outdoor) Termination for Copper Tape, Wire Shield, Lead Sheath, and UniShield Cable Suggested Installation Equipment (not supplied with kit) Cable

More information

Scotch Heavy Duty Vinyl Electrical Tape 22

Scotch Heavy Duty Vinyl Electrical Tape 22 Scotch Heavy Duty Vinyl Electrical Tape 22 Data Sheet July 2015 Description Agency Approvals & Self Certifications Scotch Heavy Duty Vinyl Electrical Tape 22 is a premium grade, 10-mil thick, vinyl insulating

More information

Instructions. Cable with Armor F CAUTION. October Rev A

Instructions. Cable with Armor F CAUTION. October Rev A 3M Single Conductor Accessory Breakout Kits (BOK's) for use with 3M Cable Accessories (Terminations, T-Bodies and Push-On Elbows) For Use With Single Conductor Accessories On Three-Core Conductor Cables

More information

NC-1000 INSTALLATION MANUAL NC-1000 FIBRE OPTIC CROSS-CONNECTION SYSTEM

NC-1000 INSTALLATION MANUAL NC-1000 FIBRE OPTIC CROSS-CONNECTION SYSTEM NC-1000 INSTALLATION MANUAL NC-1000 FIBRE OPTIC CROSS-CONNECTION SYSTEM Content 1. General 5 2. The products of NC-1000 system 6 3. Mounting of the frame 8 4. Earthing of the frame 8 NC-1000 FIBRE OPTIC

More information

2179-CD Series Fiber Optic Splice Closure. Installation Instructions

2179-CD Series Fiber Optic Splice Closure. Installation Instructions 2179-CD Series Fiber Optic Splice Closure Installation Instructions 1.0 Product Introduction The new 3M TM 2179-CD Series Fiber Optic Splice Closure can be used in buried, underground, aerial, and pedestal

More information

ELECTRICAL SAFETY INSPECTION REPORT. MTM Garments Ltd.

ELECTRICAL SAFETY INSPECTION REPORT. MTM Garments Ltd. ELECTRICAL SAFETY INSPECTION REPORT MTM Garments Ltd. 15934/16004, Chanpara, Medical Road, Uttarkhan, Dhaka, Bangladesh. Factory List MTM Garments Ltd. Inspected by: Hemlal Dahal Report Generated by: Hemlal

More information

POLICY & APPLICATION GUIDE FOR 11kV POLYMERIC CABLES

POLICY & APPLICATION GUIDE FOR 11kV POLYMERIC CABLES 1. SCOPE This document provides information and guidance on the application of polymeric cables on the SPEN 11kV network. Throughout this document, references to 11kV shall by inference also relate to

More information

3M Scotchcast Mine and Portable Cable Splice and Jacket Repair Kit M-40

3M Scotchcast Mine and Portable Cable Splice and Jacket Repair Kit M-40 3M Scotchcast Mine and Portable Cable Splice and Jacket Repair Kit M-40 Instructions 1 & 2 For Jacket Repair (pages 2 & 7) Supplemental Instructions for: Insulation Repair (page 12) Conductor Repair (page

More information

COMMON WORK RESULTS FOR INTEGRATED AUTOMATION DESIGN AND CONSTRUCTION STANDARD

COMMON WORK RESULTS FOR INTEGRATED AUTOMATION DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 103 2018 Test Method for DC Contact Resistance, Drop cable to F connectors and F 81 Barrels NOTICE The Society of Cable Telecommunications

More information

ENGINEERING COMMITTEE

ENGINEERING COMMITTEE ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 32 2016 Ampacity of Coaxial Telecommunications Cables NOTICE The Society of Cable Telecommunications Engineers

More information

ENGINEERING COMMITTEE Interface Practices Subcommittee SCTE Test Method for Cable Weld Integrity

ENGINEERING COMMITTEE Interface Practices Subcommittee SCTE Test Method for Cable Weld Integrity ENGINEERING COMMITTEE Interface Practices Subcommittee SCTE 178 2011 Test Method for Cable Weld Integrity NOTICE The Society of Cable Telecommunications Engineers (SCTE) Standards are intended to serve

More information

High Voltage Cable Splicing Training

High Voltage Cable Splicing Training High Voltage Cable Splicing Training Contact us Today for a FREE quotation to deliver this course at your company?s location. https://www.electricityforum.com/onsite-training-rfq High Voltage Cables are

More information

Cold Shrink Straight Joint

Cold Shrink Straight Joint Cold Shrink Straight Joint 3M QS2000E 22 kv Single Core Straight Joint Instruction Sheet All dimensions shown are in mm unless otherwise stated Kits contains components for one single core cable -2-2*

More information

LEGEND POWER SYSTEMS

LEGEND POWER SYSTEMS S HEAT SHRINK JOINT 11kV 3 CORE Armoured XLPE/EPR Copper Wire screens STRAIGHT JOINT LEGEND POWER SYSTEMS Date 11 November 2014 Instruction Number PJJ006-14C PJJ006-14C Page 1 of 10 HEAT SHRINKABLE JOINT

More information

SPECIAL SPECIFICATION 2344 TMC Support Equipment

SPECIAL SPECIFICATION 2344 TMC Support Equipment 2004 Specifications CSJ 0912-00-488 SPECIAL SPECIFICATION 2344 TMC Support Equipment 1. Description. Furnish Traffic Management Center (TMC) support equipment in the City of Missouri City TMC location

More information

Operating instructions

Operating instructions 108183 2017-05-17 Page 1 0359 Operating instructions TPPL-EX series Hazardous environments luminaires Please read the instructions carefully before starting any works! Content: 1. Safety instructions 2.

More information

IndyGo Facility Upgrades Project 35671EE

IndyGo Facility Upgrades Project 35671EE SECTION 260553 IDENTIFICATION FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Identification for raceways. 2. Identification of power and control cables. 3. Identification for

More information

Instrumentation Cables

Instrumentation Cables Instrumentation Cables 9 KEWBERG manufactures and supplies a wide range of Instrumentation cables, which are made using superior raw materials. These are extensively used in data acquisition systems, process

More information

Identification - electrical services

Identification - electrical services Identification - electrical services Aesthetic All live phase cable sheathing to be brown coloured and neutral phase cable sheathing to be blue coloured, all labelled L1, L2, L3 & N respectively in accordance

More information

CLP s first 400kV XLPE cable application

CLP s first 400kV XLPE cable application CLP s first 400kV XLPE cable application Chris Cheung CLP Power Hong Kong Limited 9 October 2017 Information Classification : PROPRIETARY Information Classification : PROPRIETARY Project Requirement Due

More information

3M Cold Shrink QS4 Integrated Splice Kit QS4-15SP-2-4/0

3M Cold Shrink QS4 Integrated Splice Kit QS4-15SP-2-4/0 3M Cold Shrink QS4 Integrated Splice Kit QS4-15SP-2-4/0 for Jacketed Concentric Neutral (JCN), Flat Strap, Tape Shield and Longitudinally Corrugated (LC) Cable Instructions IEEE Std. 404 15 kv Class 150

More information

ACADEMIC SUCCESS CENTER THE COLLEGE AT BROCKPORT STATE UNIVERSITY OF NEW YORK PROJECT NO

ACADEMIC SUCCESS CENTER THE COLLEGE AT BROCKPORT STATE UNIVERSITY OF NEW YORK PROJECT NO SECTION 270536 - CABLE TRAYS FOR COMMUNICATIONS SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

UNDERGROUND CONSTRUCTION MANUAL MATERIAL DATA

UNDERGROUND CONSTRUCTION MANUAL MATERIAL DATA UNDERGROUND CONSTRUCTION MANUAL Back to MAIN INDEX Go to SECTION INDEX CONSTRUCTION DESCRIPTION DWG CONSTRUCTION DESCRIPTION DWG LV cable details 5108 HV cable details 5109 Insect protected LV cable details

More information

ELECTRICAL SAFETY FOLLOW UP INSPECTION REPORT (8th) Factory Name Address Factory ID

ELECTRICAL SAFETY FOLLOW UP INSPECTION REPORT (8th) Factory Name Address Factory ID Factory Name Address Factory ID Shirir Chala, Bagherbazar 11705 Electrical Safety dates Initial Date 09/07/2014 30/10/2016 Date of 5 th Follow Up Report Received Date 24/08/2014 02/01/2017 Date of 6 th

More information

Specification for Loose Tube Fiber Optic Cable (Non-Metallic, Dry Block, Figure-8) (G.652.D)

Specification for Loose Tube Fiber Optic Cable (Non-Metallic, Dry Block, Figure-8) (G.652.D) 2-3, Marunouchi 2-chome, Chiyoda-ku, Tokyo 100-8322, Japan No. FB-KL4001C for Loose Tube Fiber Optic Cable (Non-Metallic, Dry Block, Figure-8) (G.652.D) Aug 2014 1 1. General This specification describes

More information

Power and Control T YPE BY RAVI GANATR November/December IAEI NEWS

Power and Control T YPE BY RAVI GANATR November/December IAEI NEWS Power and Control 26 1999 November/December IAEI NEWS T YPE BY RAVI GANATR This article discusses how the requirements in both the installation code and the product standard are utilized to manufacture

More information

Quick Term II. Cold Shrink Silicone Rubber Termination (With High-K Stress Relief) Instruction Sheet. Quick Term II. Silicone Rubber Termination Kits

Quick Term II. Cold Shrink Silicone Rubber Termination (With High-K Stress Relief) Instruction Sheet. Quick Term II. Silicone Rubber Termination Kits Quick Term II Cold Shrink Silicone Rubber Termination (With High-K Stress Relief) Instruction Sheet IEEE Std. No. 48 1990 Class 1 Termination 15 kv Class 110 kv BIL Kit Contents: 3 Hi K Silicone Rubber

More information

ENGINEERING COMMITTEE Interface Practices Subcommittee. ANSI/SCTE (Formerly IPS SP 001)

ENGINEERING COMMITTEE Interface Practices Subcommittee. ANSI/SCTE (Formerly IPS SP 001) ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 74 2003 (Formerly IPS SP 001) Specification for Braided 75 Ω Flexible RF Coaxial Drop Cable NOTICE The Society

More information

AMERICAN NATIONAL STANDARD

AMERICAN NATIONAL STANDARD ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 153 2008 Drop Passives: Splitters, Couplers and Power Inserters NOTICE The Society of Cable Telecommunications

More information

HSK Mine and Portable Cable Splice

HSK Mine and Portable Cable Splice 8096-4-HSK Mine and Portable Cable Splice Instructions 5 and 8 kv rated cables; Type SHD-GC Size 2/0 4/0 (connector max. length 2 1/2") 8096-4-HSK Mine and Portable Cable Splice 78-8119-6296-4-A 1 1.0

More information

Drop Passives: Splitters, Couplers and Power Inserters

Drop Passives: Splitters, Couplers and Power Inserters ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 153 2016 Drop Passives: Splitters, Couplers and Power Inserters NOTICE The Society of Cable Telecommunications

More information

SECTION 7 -- CROSS-CONNECT SYSTEMS

SECTION 7 -- CROSS-CONNECT SYSTEMS DETAIL ENGINEERING REQUIREMENTS AT&T March, 2016 Section 7, ATT-TP-76400 Revised NA SECTION 7 -- CROSS-CONNECT SYSTEMS CONTENTS PAGE 1. GENERAL... 7-2 1.1. Introduction... 7-2 1.2. Cable Holes... 7-2 1.3.

More information

Revision of Qualification Procedures for High Voltage and Extra High Voltage AC Extruded Underground Cable Systems

Revision of Qualification Procedures for High Voltage and Extra High Voltage AC Extruded Underground Cable Systems Revision of Qualification Procedures for High Voltage and Extra High Voltage AC Extruded Underground Cable Systems Tutorial vor the ICC Educational Session on November 11 2009 in Scottsdale, AZ by Wim

More information

Installation Guide VL-MV10. Model No.

Installation Guide VL-MV10. Model No. Installation Guide Model Name Model No. Main Monitor Station VL-MV0 R Main monitor station is described as "main monitor" in this guide. R In this guide, the suffix of each model number (e.g., the "EX"

More information

INSTALLATION INSTRUCTION PEM1368ENG ENGLISH

INSTALLATION INSTRUCTION PEM1368ENG ENGLISH INSTALLATION INSTRUCTION PEM1368ENG 2015-01 ENGLISH COLD SHRINK HYBRID JOINT CJH11.42 FOR SINGLE CORE CABLES WITH Cu WIRE SHIELD Uo/U = 20.8/36 kv, Um = 42 kv 2/10 CJH11.42 PEM1368ENG 2015-01 GENERAL INFORMATION

More information

Automatic Connector MHV Connectors MHV Introduction MHV series connectors Contents Polarized mating interfaces Anti-Rock mating interfaces

Automatic Connector MHV Connectors MHV Introduction MHV series connectors Contents Polarized mating interfaces Anti-Rock mating interfaces Automatic s 2004 Automatic. All rights reserved. pdf 1.0 3-18-04 Contents Specifications........................... 2 Straight Cable Plugs...................... 3 Right Angle Cable Plugs...................

More information

HN Connectors. Automatic Connector. Introduction. Contents. 631/ FAX 631/

HN Connectors. Automatic Connector. Introduction. Contents. 631/ FAX 631/ Connectors Introduction 2004 Automatic Connector. All rights reserved. pdf 1.0 4-13-04 Contents Specifications........................... 2 Straight Cable Plugs...................... 3 Right Angle Cable

More information

UNSIGNED HARDCOPY NOT CONTROLLED

UNSIGNED HARDCOPY NOT CONTROLLED SUBJECT: APPROVED BY STATUS PURPOSE AFFECTED FUNCTIONS REFERENCES Cable and Harness Making Manager, Hardware Engineering Maintenance Revision Establishes requirements for the fabrication and inspection

More information

3M Sensored Termination (15 kv) QX-T15I-vi1-E

3M Sensored Termination (15 kv) QX-T15I-vi1-E 3M Sensored Termination () QX-T15I-vi1-E Data Sheet May 2016 Kit Contents: Each kit contains sufficient quantities of the following materials to make three single-phase terminations. 31" (REF) One piece

More information

Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD Specification for Braided 75 Ω, Mini-Series Quad Shield Coaxial Cable for CMTS and SDI cables NOTICE The Society of Cable Telecommunications

More information

TRF STEP-DOWN TRANSFORMER USER MANUAL

TRF STEP-DOWN TRANSFORMER USER MANUAL TRF STEP-DOWN TRANSFORMER USER MANUA www.ventilation-system.com 2013 ! WARNING The present operation manual consisting of the technical details, operating instructions and technical specification applies

More information

Low Voltage Splices, 1000 V or less

Low Voltage Splices, 1000 V or less For installations from 120 V to 1 kv, 3M offers several low voltage splice options, including 3M-developed cold shrink technology, heat shrink, resin and tape. 3M Low Splices are reliable in buried, overhead,

More information

SECTION CONTROL, COMMUNICATION AND SIGNAL WIRING

SECTION CONTROL, COMMUNICATION AND SIGNAL WIRING PART 1 - GENERAL 1.1 DESCRIPTION SECTION 27 10 00 CONTROL, COMMUNICATION AND SIGNAL WIRING SPEC WRITER NOTES: 1. Edit this specification section between // //, to fit project, or delete if not applicable.

More information

3 Cleaning. 4 Technical data

3 Cleaning. 4 Technical data EXC+ EXC- Sig- SIG+ SEN- SEN+ 2.4 Attaching cable to the analog board Attaching cable of the weighing cell to the system solution Connect the cable to the appropriate terminal strip of the Ex1 system solution

More information

D-COAX, Inc. D-COAX d086 Series Cable Pair. High Frequency, Skew Matched, Phase Stable Cable Pair (65 GHz)

D-COAX, Inc. D-COAX d086 Series Cable Pair. High Frequency, Skew Matched, Phase Stable Cable Pair (65 GHz) D-COAX, Inc. D-COAX d086 Series Cable Pair High Frequency, Skew Matched, Phase Stable Cable Pair (65 GHz) D-COAX d086 Series Cable Pair consists of two skew matched (to 1ps) flexible cable assemblies with

More information

VITALink Taped Splice Straight Through Crimp

VITALink Taped Splice Straight Through Crimp A Marmon Wire & Cable Berkshire Hathaway Company VITALink Taped Splice Straight Through Crimp 2 Hour Fire-Rated Splice VITALink MC Cables, UL FHIT 120 Installation Instructions Description The VITALink

More information

1993 Specifications CSJ , etc. SPECIAL SPECIFICATION ITEM CCTV Central Equipment

1993 Specifications CSJ , etc. SPECIAL SPECIFICATION ITEM CCTV Central Equipment 1993 Specifications CSJ 0922-33-042, etc. SPECIAL SPECIFICATION ITEM 8549 CCTV Central Equipment 1. Description. This Item shall govern for the furnishing and installation of closed circuit television

More information

SINAMICS G130. dv/dt filter plus Voltage Peak Limiter. Operating Instructions 03/2013 SINAMICS

SINAMICS G130. dv/dt filter plus Voltage Peak Limiter. Operating Instructions 03/2013 SINAMICS SINAMICS G130 Operating Instructions 03/2013 SINAMICS s dv/dt filter plus Voltage Peak Limiter Safety information 1 General 2 SINAMICS SINAMICS G130 Operating Instructions Mechanical installation 3 Electrical

More information

Installation instructions Roxtec RM ES B

Installation instructions Roxtec RM ES B Installation instructions Roxtec RM ES B Environmental side Termination/ interior side Pipe Cable screen/armor Layers Termination/ interior side Cable sheath Layers Environmental side Vertical screen Plastic

More information

640 kv XLPE HVDC cable system

640 kv XLPE HVDC cable system 640 kv XLPE HVDC cable system World s most powerful extruded cable system enables utilization of renewable energy resources nkt.com Demand for higher voltages NKT s new 640 kv XLPE DC cable system is the

More information

ENCAPSULATED TRANSFORMERS FOR HARSH LOCATIONS

ENCAPSULATED TRANSFORMERS FOR HARSH LOCATIONS SECTION ENCAPSULATED TRANSFORMERS FOR HARSH LOCATIONS 600 Volt Class, Encapsulated Single Phase and Three Phase Description and Applications... 8 Copper NEMA R Features... 8 Copper Single Phase Selection

More information

Dry Type Transformers. Section 10. BuyLog Catalog 10-1

Dry Type Transformers. Section 10.  BuyLog Catalog 10-1 For more information on these products, order publications listed in Section 27. Find What You Need Faster - Page headings and table format make product selection easier. Easy Cross Reference - Frame size

More information

STANDARD FOR MULTI-DWELLING UNIT (MDU) OPTICAL FIBER CABLE. Publication S First Edition - June 2012

STANDARD FOR MULTI-DWELLING UNIT (MDU) OPTICAL FIBER CABLE. Publication S First Edition - June 2012 STANDARD FOR MULTI-DWELLING UNIT (MDU) OPTICAL FIBER CABLE Publication S-115-730 First Edition - June 2012 Published By Insulated Cable Engineers Association, Inc. Post Office Box 1568 Carrollton, Ga 30112,

More information

INSTRUCTION DE SÉCURITÉ SAFETY INSTRUCTION Mandatory as defined in SAPOCO/42 FIRE PREVENTION FOR CABLES, CABLE TRAYS AND CONDUITS

INSTRUCTION DE SÉCURITÉ SAFETY INSTRUCTION Mandatory as defined in SAPOCO/42 FIRE PREVENTION FOR CABLES, CABLE TRAYS AND CONDUITS CERN INSTRUCTION DE SÉCURITÉ SAFETY INSTRUCTION Mandatory as defined in SAPOCO/42 Edms 335813 TIS IS 48 Edited by: TIS/GS Publication Date: June 2001 Original: English FIRE PREVENTION FOR CABLES, CABLE

More information

Non Magnetic Connectors

Non Magnetic Connectors Non Magnetic Connectors Johnson Components builds coaxial connectors using innovative materials and design to provide Mil Spec Performance at a commercial price. Now we offer our Non Magnetic Connectors

More information

High Temperature Operation of Extruded Distribution Cable Systems. White Paper

High Temperature Operation of Extruded Distribution Cable Systems. White Paper High Temperature Operation of Extruded Distribution Cable Systems White Paper October 2018 NOTICE The information contained herein is, to our knowledge, accurate and reliable at the date of publication.

More information

Draft for Public Comment

Draft for Public Comment Draft for Public Comment Form 36 Version 6.1 DPC: 03/302646 DC Head Office 389 Chiswick High Road London W4 4AL Telephone: +44(0)20 8996 9000 Fax: +44(0)20 8996 7001 Date: 27 March 2003 Origin: National

More information

Installation instructions Roxtec RM PE B

Installation instructions Roxtec RM PE B Installation instructions Roxtec RM PE B Environmental side Termination/ interior side Pipe Cable screen/armor Layers Termination/ interior side Cable sheath Layers Environmental side Plastic film Conductive

More information

PRODUCT CATALOGUE 2016

PRODUCT CATALOGUE 2016 Power cables accessories for low, medium and low-high voltage 2016 PRODUCT CATAOGUE 2016 Content Page ow Voltage product range 5 Medium Voltage Terminations 15 Medium Voltage joints 29 OW-High Voltage

More information

Safety Codes Council Conference Banff C Panel Discussion

Safety Codes Council Conference Banff C Panel Discussion Safety Codes Council Conference Banff 2014 90 C Panel Discussion Tim Driscoll OBIEC Consulting Ltd. George Morlidge Fluor Canada Ltd. Scott Basinger Eaton Canada René Leduc Marex Canada Limited Perspectives

More information