Data Sheet Definite Purpose Contactors Ex9CK Series
|
|
- Frederick Armstrong
- 5 years ago
- Views:
Transcription
1 Data Sheet Ex9CK Series Ex9CK40B0 Ex9CKA10 na.noarkelectric.com
2 NOARK Ex9CK Series Features Ex9CK Series DP Contactors provide high performance with both flexibility and reliability. They are designed to match numerous applications including: HVACR Resistive heating Refrigeration equipment Motors Welding Pumps Power supplies Food serivce equipment Compressors Business machines Available as: Rated current from 0~90 A 1,, and pole configurations Enclosed coil standard for all pole frame sizes Open coil standard for all 1 and pole frame sizes Industry standard mounting plate provides easily accessible mounting holes Connection terminal options, including screw or lug connections each with quick connect spades Coil is Class B 66 F (10 C) insulation system with a wide range of voltages and 50/60 Hz ratings Double E magnet assembly provides optimal performance with reduced power consumption 1NO+1NC auxiliary contact block with 600 Vac rating available as an option Base assembly is made from high arcresistant polyester Certifications UL Recognized Component, File Number E5866 Certified for Canada according to CSA standards IEC/EN Complies with VDE standards RoHS Compliant 019 NOARK Electric
3 Ex9CK Product Selection Guide and Packaging Product Selection Guide Ex9CK 40 A 10 G 7 Q NOARK Ex9CK Series Full Load Amperage (FLA) Terminal Pole Coil Voltage Frequency Quick Connection Terminal for P 0: 0 A 5: 5 A 0: 0 A : A 40: 40 A 50: 50 A 60: 60 A 75: 75 A 90: 90 A A: Screw B: Lug 10: 1NO+1Shunt 0: NO 0: NO B: 4V N: 77 V C: 6 V Q 1 : 80 V D: 4 V V: 400 V E: 48 V N: 415 V F: 110 V R: 440 V G: 10 V T: V M: 0 V S: 500 V P: 0 V Y: 600 V 7: 50/60 Hz Blank: Open Coil (1 & Pole) Enclosed Coil ( Pole) Packaging Full Load Amperage (A) MOQ Quantity (pc/carton) Carton Weight Piece Weight lbs (kgs) lbs (kgs) Gross Gross Net Carton Dimensions in (mm) (16.65) 0.57 (0.6) 0.51 (0.) 15.67x9.5x (1.1) 0.7 (0.) 0.64 (0.9) (98x4x1) (5.6) 1.04 (0.47) 0.97 (0.44) 18.66x1.68x10.75 (474xx7) (16.65) 0.57 (0.6) 0.51 (0.) 15.67x9.5x (1.1) 0.7 (0.) 0.64 (0.9) (98x4x1) (5.6) 1.04 (0.47) 0.97 (0.44) 18.66x1.68x10.75 (474xx7) (16.65) 0.57 (0.6) 0.51 (0.) 15.67x9.5x (1.1) 0.7 (0.) 0.64 (0.9) (98x4x1) (5.6) 1.04 (0.47) 0.97 (0.44) 18.66x1.68x10.75 (474xx7) (16.00) 0.55 (0.5) 0.51 (0.) 15.67x9.5x (1.1) 0.7 (0.) 0.64 (0.9) (98x4x1) (5.6) 1.04 (0.47) 0.97 (0.44) 18.66x1.68x10.75 (474xx7) (16.00) 0.55 (0.5) 0.51 (0.) 15.67x9.5x (1.1) 0.7 (0.) 0.64 (0.9) (98x4x1) (5.6) 1.04 (0.47) 0.97 (0.44) (17.9) 1.41 (0.64) 1.8 (0.58) (19.70).6 (1.64). (1.51) 18.66x1.68x10.75 (474xx7) 15.67x9.5x1.64 (98x4x1) 14.x8.8x16.50 (64x4x419) All Rights Reserved
4 Ex9CK Specifications 0~40 A 0~40 FLA Description Ex9CK0 Ex9CK5 Ex9CK0 Ex9CK Ex9CK40 Full Load Amperage (A) Locked Rotor (A) Horsepower (hp) 40/77 V V 600 V 600 Vac (A) 40/77 V V 600 V Voltage (V) 1Phase Phase Shunt / Shunt / Shunt / Shunt / Shunt / NOARK Electric
5 Ex9CK Specifications 0~40 A Ex9CK Power Consumption* Operation Range InRush 50 Hz Sealed 50 Hz InRush 60 Hz Sealed 60 Hz PickUp Voltage DropOut Voltage Power Supply Voltage Us Terminal Connection Line and Load Terminals Copper Cable AWG (mm ) Tightening Torque inlb (N.m) Quick Connects 1 Pole+ Shunt 1 Pole+ Shunt 1 Pole+ Shunt 1 Pole+ Shunt 1 Pole+ Shunt ~110% Us 0~65% Us 50/60 Hz; 4~600 Vac #10 Screw Box Lug Ridge Wire Screw 14~10 (.5~6) 1~8 (4~10) 16~8 (1.5~10) ~8 (4~10) with Single Core Lug 14~8 (.5~10) Flexible Stranded Wire Screw 14~1 (.5~6) Lug 14~8 (.5~10) Coil Main Circuit Insulation System Power Terminals Coil Terminals Screw 1P: 0 (1.8~) P, P: 0 (1.8) Lug 40 (4~6) Dual or 0.50 Standard Quad Quad** Dual or Dual Quad Quad** Dual or Dual Quad Quad** Dual 0.50 QC () Dual Class B 66 F (10 C) Dual or Quad Quad** 16~8 (1.5~10) ~8 (4~10) 16~8 (1.5~10) Dual or Dual Quad Quad** Dual * Power consumption is the same for 4, 10, 40, 77 and Vac. ** Dual is standard. Mechanical & Electrical Life Mechanical Electrical 1,000,000 cycles 50,000 cycle (AC Resistance Air Heating Load) All Rights Reserved 5
6 Ex9CK Specifications 50~90 A 50~90 FLA Description Full Load Amperage (A) Locked Rotor (A) Horsepower (hp) 40/77 V V 600 V 600 Vac (A) 40/77 V V 600 V Voltage (V) 1Phase Phase 110/10 00/ Ex9CK / / / Ex9CK / / / Ex9CK / / / Ex9CK / ~90 FLA Coil Power Consumption* Operation Range Power Supply Voltage Us InRush 50 Hz Sealed 50 Hz InRush 60 Hz Sealed 60 Hz PickUp Voltage DropOut Voltage ~110% Us 0~65% Us 50/60 Hz; 4~600 Vac * Power consumption is the same for 4, 10, 40, 77 and Vac NOARK Electric
7 Ex9CK Specifications 50~90 A and SCCR Ratings 50~90 FLA Terminal Line and Load Terminals Copper Cable AWG (mm ) Tightening Torque inlb (N.m) Quick Connects #10 Screw Box Lug Ridge Wire Screw with Single Core Lug 10~6 (6~16) 14~6 (.5~16) 6~ (16~5) 4~ (5~5) Flexible Stranded Wire Screw Lug 10~8 (4~10) 8~4 (10~5) 8~4 (16~5) Coil 10 (0.8~1.) Main Circuit Power Terminals Coil Terminals Screw Lug 50 (4~7) Dual 0.50 QC () Dual 0.50 QC () 6~ Screw and 0.50 QC () 0.50 Standard Dual Dual 0.50 QC () Covers Insulation System Standard Class B 66 F (10 C) SCCR Ratings SCCR: 100kA@Vac with max. with Fuse Ex9CK 0 & 5A (1P) Ex9CK 0 & A (1P) Ex9CK 40A (1P) Ex9CK 50A Ex9CK 60A Ex9CK 75A Ex9CK 90A CB rated current A M1N 50A M1N 50A M1N 70A M1N 100A M1N 100A MN 15A MN 15A Fuse rated current A CB: must be NOARK UL MCCB M1N or MN. Fuse type: Class J or Class L (Class L fuse required for applications with 100A or greater) Lighting Data 550A; 1//P Inductive Rating (DP Contactor FLA) 5A 0A 40A 50A Tungsten & Ballast Rating 0A 40A 50A 60A All Rights Reserved 7
8 Ex9CK Dimensions 0~40 Ex9CK0~40 1 Pole+Shunt 0.0 [5].6 [9] max 0.87 [] 0.0 [5] R 1.6 [41.] max Ex9CK0~ [41.] 1.77 [45].17 [55] max.64 [67] max 0.0 [5].6 [9] max R 0.87 [] 1.6 [41.] Ex9CK0~40.04 [51.7] 1.48 [7.5] ø0. [ø5.5].75 [95.] max ø0. [ø5.5].19 [81].5 [8.5] 0.0 [5].17 [55] max 1.77 [45].64 [67] max.66 [67.5] max.87 [7] max ø0. [ø5.5] 1.48 [7.5].4 [57] ø0. [ø5.5] NOARK Electric
9 Ex9CK Dimensions 0~40 50 ~ 90 Ex9CK50~60.04 [51.7] 1.48 [7.5] ø0. [ø5.5].91 [74].5 [64] ø0. [ø5] 5.4 [1] max ø0. [ø5] 4.40 [11] 4.60 [117] 4.65 [118] max ø0. [ø5.5].19 [81].5 [8.5] Ex9CK75~90.66 [67.5] max.11 [79] max ø0. [ø5.5] 1.48 [7.5].4 [57] ø0. [ø5.5].50 [89] max 4.57 [116] max ø0. [ø5].5 [64] All Rights Reserved 019 NOARK Electric 9
10 Ex9CK: Wiring Diagram and Mounting Positions Line Side Ex9CK0~40 Ex9CK0~90 A1 1/L1 A1 1/L1 /L A /T1 A /T1 4/T Ex9CK... 1P 1NO+1Shunt Ex9CK... P NO Ex9CK... P NO Load Side Ex9CK0~ NOARK Electric
11 Ex9CK Accessories: Specifications and Packaging Selection Guide AXF C 11 Q Description Coil Pole Connection Auxiliary Contact (Side Mount) C: Enclosed Coil Contact for 0~90 A ( pole only D: Microswitch for 0~40 A ( pole only) 11: 1NO+1NC : NO+NC Q: Quick Connect Blank: Screw Connect Dimensions AXFC11/AXFC11Q 0~90 A ( pole only).5 [85] max.56 [65] max.54 [64.5] 0.70 [17.7] max.70 [68.5] 0.9 [10] AXFD11/AXFD 0~40 A ( pole only).7 [69] max 1.8 [5.1] 0.91 [] max 0.6 [16] max.49 [6.].68 [68] max All Rights Reserved 019 NOARK Electric 11
12 Ex9CK Accessories: Specifications and Packaging Auxiliary Contact AXFC11/AXFC11Q AXFD11 AXFD Compatable With Ex9CK0~90 Pole Ex9CK0~40 Pole Microswitch SPDT One Switch Per Side SPDT Two Switches Per Side Mounting Side Mounted (Maximum of two) One Auxillary Only 1NO+1NC 1NO+1NC NO+NC 0.50 Quick Connection Terminals Wiring #6~ Screw Terminal Ratings 10 Vac DropOut (A) 40 Vac 1.50 Vac Vac Vac 0 PickUp (A) 40 Vac 15 Vac Vac 6 10 Vac Continuous (A) 40 Vac Vac 600 Vac 10 Current Ratings 15 or 50 Vac 15A 10 Vac on Lamp Load 4 A 15 Vdc 1/ A 50 Vdc 1/4 A Packaging Accessory Quantity (pc/carton) Carton Weight lbs (kgs) Piece Weight lbs (kgs) Carton Dimensions Gross Gross Net in (mm) AXFC (6.74) 0.09 (0.04) (0.04) 18.66x9.67x10.75 (474x46x7) AXFC11Q (10.1) 0.11 (0.05) (0.06) AXFD (4.64) 0.07 (0.0) 0.04 (0.0) 150 AXF 1.54 (6.14) 0.09 (0.04) 0.07 (0.0) 15.67x9.84x1.19 (98x50x5) 18.66x9.67x10.75 (474x46x7) 18.66x9.67x10.75 (474x46x7) NOARK Electric
13 NOARK Electric North America 188 Pomona Blvd, Pomona Ca (66) na.noarkelectric.com Note: NOARK Electric reserves the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. NOARK Electric nor any of its affiliates or subsidiaries shall be responsible or liable for potential errors or possible lack of information in this document. NOARK Electric reserves all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of NOARK Electric. 019 NOARK Electric All Rights Reserved DSDP01901NA
Agency approvals UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B
11 Applications Type DP provide high performance with flexibility and reliability, designed to match numerous applications including: Motors Power supplies Food service equipment Compressors Business machines
More informationAC1036. Definite Purpose Contactors
Definite Purpose Contactors Definite purpose contactors Definite purpose Contactors Applications Type DP contactors provide high performance with flexibility and reliability, designed to match numerous
More informationContactors. Agency approvals. UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B
Contactors Applications Type DP provide high performance with flexibility and reliability, designed to match numerous applications including: Motors Power supplies Food service equipment Compressors Business
More informationSeries CDP2 Definite Purpose Contactors
Series 2 Definite Purpose High performance economical contactors for commercial applications up to 90 Sprecher + Schuh s Definite Purpose contactors are ideal for commercial applications including air
More informationSeries CDP2 Definite Purpose Contactors
Series CDP2 Definite Purpose Contactors High performance economical contactors for commercial applications up to 90 Sprecher + Schuh s Definite Purpose contactors are ideal for commercial applications
More informationMovable Contacts Heavy duty silver cadmium oxide composition to resist welding and contact erosion for greater reliability
Compare These Features Built-in Shock bsorber Reduces contact bounce for longer life. Coil Dust Cover Keeps dust and dirt away from magnet and coil area. Coil Class B (1300 C Insulation System) with wide
More informationDefinite Purpose Contactors
Definite Purpose Contactors Your order must include: 1) complete cat. no. of selected contactor, and 2) auxiliary contacts, if required. 20/25 FLA 1 and 2 Pole 1-Pole Contactor with Shunt 2-Pole Contactor
More informationMagnecraft Power Relays
Description DPST-NO, 30 A; DPDT, 30 A (NO) / 3 A (NC) Description The series power relays offer a small package size and features Class F insulation for a maximum coil temperature of 55 C (3 F). These
More informationPBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories
PBC series IEC-Type Contactors & Accessories 9-80 Amp AC-3, 25-125 Amp AC-1 AC Coils File E38802 (PBC) RoHS Ready Users should thoroughly review the technical data before selecting a product part number.
More informationLC1D25G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A V AC coil
Product data sheet Characteristics LC1D25G7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationLC1D09B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V AC coil
Product data sheet Characteristics LC1D09B7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationLC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A V AC coil
Product data sheet Characteristics LC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationLC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC
Product datasheet Characteristics LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC Price* : 86.25 GBP Main Range Product name Product or component type Device short name Contactor application Utilisation category
More informationLC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil
Product data sheet Characteristics LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationLC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil
Product datasheet Characteristics LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationTeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40
Characteristics Type of contactor LC- LC- LC- LC- LC-D & D09 D8 D2 D38 D40 D0 D9 LC-D0 DT20 & DT2 DT32 & DT40 Environment Rated insulation voltage (Ui) Conforming to IEC 947-4-, overvoltage category III,
More informationAS09..S 3-pole Contactors - Spring Terminals
4 kw 5 hp AS09..S 3-pole Contactors - Spring AC Operated Description - 3-pole contactors with spring terminals, - N.C. or N.O. built-in auxiliary contact, - Rail-mounted, no tools required, - Additional
More informationLC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil
Product datasheet Characteristics LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationType: DILM25 10(24V50HZ) Article No.:
Type: DILM25 10(24V50HZ) Article No.: 277119 Ordering information Rated operational current AC 3 400 V I e A 25 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors,
More informationLC1D32P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A V AC 50/60 Hz coil
Characteristics TeSys D contactor - 3P(3 NO) - AC-3 -
More informationLC1D12P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A V AC coil
Characteristics TeSys D contactor - 3P(3 NO) - AC-3 -
More informationSeries CT7N Bimetallic Overload Relays
Series CT7N imetallic Overload Relays Choose CT7N overloads in DC applications and when monitoring Variable Frequency Drives Sprecher + Schuh has always paid particular attention to the subject of motor
More informationA V 50Hz / V 60Hz
A16-22-00 400-415V 50Hz / 415-440V 60Hz Products Low Voltage Products and Systems Control Products Contactors Block Contactors General Information Extended Product Type: A16-22-00 400-415V 50Hz / 415-440V
More informationMinicontactorrelay,2NO/2NC,DCoperated
Minicontactorrelay,2NO/2NC,DCoperated Partno. DILER-22-G(24VDC) Articleno. 010042 CatalogNo. XTRM10A22TD Deliveryprogramme Product range DILER Mini-contactors Application Contactor relays Connection technique
More informationLC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil
Product data sheet Characteristics LC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationLC3D180AV7 TeSys D - star delta starter - 3 x 3P (3 NO) - 18 A V AC coil
Characteristics TeSys D - star delta starter - 3 x 3P (3 NO) - 18 A - 400 V AC coil Main Range Product name Product or component type Device short name Contactor application Utilisation category Device
More informationLC1D12B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V AC coil
Characteristics TeSys D contactor - 3P(3 NO) - AC-3 -
More informationLC1D150B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A - 24 V AC 50/60 Hz coil
Product data sheet Characteristics LC1D150B7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationLC1D65AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC 50/60 Hz coil
Characteristics TeSys D contactor - 3P(3 NO) - AC-3 -
More informationLC1D50AFE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil
Product data sheet Characteristics LC1D50AFE7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationType: DILM12 10(24VDC) Article No.:
Type: DILM12 10(24VDC) Article No.: 276845 Ordering information Rated operational current AC 3 400 V I e A 12 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors,
More information3.5. Control Relays and Timers. Contents. 9575H Series 3000 Type AA, AC and DC. General Purpose Relays Type AA
.5 9575H Series 000 Relay Contents 9575H Series 000 Type AA, AC and DC Product Selection....................... Accessories............................ Technical Data and Specifications........... Dimensions............................
More informationClimatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC
Deliveryprogramme Contactorrelay,3N/O+1N/C,AC Partno. DILER-31(230V50HZ,240V60HZ) Articleno. 051768 CatalogNo. XTRM10A31F Product range DILER Mini-contactors Application Contactor relays Description with
More informationLC3D80B7 TeSys D - star delta starter - 3 x 3P (3 NO) - 80 A - 24 V AC coil
Characteristics TeSys D - star delta starter - 3 x 3P (3 NO) - 80 A - 24 V AC coil Price* : 4058.00 USD has not been replaced. Please contact your customer care center for more information. Main Range
More informationLC3D115M7 TeSys D - star delta starter - 3 x 3P (3 NO) A V AC coil
Characteristics TeSys D - star delta starter - 3 x 3P (3 NO) - 115 A - 220 V AC coil Main Range Product name Product or component type Device short name Contactor application Utilisation category Device
More informationBulletin 190 IEC Modular Starter System
Bulletin 90 Table of Contents Selection Guide Description Page Bulletin 90....................................... Accessories....................................... 7 Specifications.....................................
More informationLC1D09M7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil
Bảng thông số sản phẩm Đặc diểm LC1D09M7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationwith handle LIMOGES Cedex 1. DESCRIPTION - USE 3. DIMENSIONS Symbol: Technology: Use:. For controlling a load remotely via a switch 2.
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 25A power contactors silent CONTENTS PAGES 1. Description, use... 1 2. Range... 1 3. Dimensions... 1 4. Positioning - Connection...
More informationPower Circuit of a UL508A Panel. Typical UL489 Application
Typical UL489 Application Power Circuit of a UL508A Panel Disclaimer: This is an application example. Installation should be done by a qualified electrician under the guidance of UL specifications.. Altech
More informationand Refrigeration Institute). Hydraulic Elevator Wye-Delta Contactors
C7 Series C7 Special Use designed and labeled for specific industrial applications The C7 line includes a number of contactors designed and labeled for specific industrial applications. In most cases,
More information1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control
IEC Contactors and Starters. XT Family of Contactors Contactors and Starters Product Description The Eaton XT contactors and starters includes nonreversing and reversing contactors, overload relays and
More informationand Refrigeration Institute). CAQ7 Capacitor Switching Contactors
SSN9000 Series C7 Special Use designed and labeled for specific industrial applications Special Use Capacitor switching contactors HVC rated contactors NEM size labeled contactors Lighting contactors Hydraulic
More informationGV2ME. Main. Device short name. Device application
Product datasheet Characteristics GV2ME32 TeSys GV2-Circuit breaker-thermal-magnetic - 24...32 A - screw clamp terminals Main Range Product name Device short name Product or component type Device application
More informationMagnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A
and 3DPT, 10 A UL Listed when used with proper Magnecraft s The 750R series octal base, plug-in relays offer clear or full-feature covers with multiple mounting options and accessories. 750R 750R Full-Feature
More informationllen-bradley 194R-HM4-NFPA3
Technical Data Rotary Disconnect Switch Specifications Bulletin Number 194R Topic Page Product Line Overview 2 General Specifications Fuse Description 12 Approximate Dimensions 14 Additional Resources
More informationSoft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit
DATASHEET - S811+N66N3S Delivery program Soft starter, 66 A, 200-600 V AC, Us= 24 V DC, with control unit, Frame size N Part no. S811+N66N3S Catalog No. 168978 Eaton Catalog No. S811PLUSN66N3S EL-Nummer
More informationMagnetic and Hydraulic-Magnetic Circuit Breaker
Magnetic and Hydraulic-Magnetic Circuit Breaker 850-... Description Single, two, three and four pole magnetic and hydraulic-magnetic circuit breakers with trip-free-mechanism and toggle or rocker actuation.
More informationDimensions and Weight Size 2.79 HEIGHT X 1.6 WIDTH X 1.19 DEPTH IN, HEIGHT X WIDTH X DEPTH MM
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 FF30MC 30MIN SPR Wound TMR Intermatic Inc. Catalog Number Manufacturer Description Weight per unit Product Category FF30MC
More information16 A and 25 A power contactors with or without handle
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 16 and 25 power contactors CONTENTS PGES 1. Description, use... 1 2. Range... 1 3. Dimensions... 1 4. Positioning -
More informationMagnecraft General Purpose Relays 782 Power Series SPDT 20 A; DPDT 15 A
72 Power Series SPDT 20 A; DPDT 15 A UL listed when used with proper Magnecraft sockets The 72 Plug-in Power relays offer clear or full-feature covers with multiple mounting options and accessories. Feature
More informationGV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A - screw clamp terminals. Main.
Product data sheet Characteristics GV2ME06 TeSys GV2-Circuit breaker-thermal-magnetic - 1...1.6 A - screw clamp terminals Main Range Product name Device short name Product or component type Device application
More informationGV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A -screw clamp terminals. Main.
Product data sheet Characteristics GV2ME04 TeSys GV2-Circuit breaker-thermal-magnetic- 0.4...0.63 A -screw clamp terminals Main Range Product name Device short name Product or component type Device application
More informationContactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122
www.stahl.de with 3 Main Contacts and max. 4 Auxiliary Contacts > Screw fastening version robust vibration resistant reliable > Corrosion resistant enclosure material > Easily accessible connection terminals
More informationType Contact form Model PCB SPDT G6E-134P-ST-US G6E-134PL-ST-US. Type Contact form Model
Low Signal Relay G6E Subminiature 7.87 H x.1 W x 16 L mm (0.31 H x 0.3 W x 0.63 L in). High sensitivity with pick-up coil power of 8 mw. Surge withstand meets FCC Part 68 rule and Telcordia 2.5 kv Specifications.
More information1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control
XT Family of Contactors Contactors and Starters Product Description The Eaton XT contactors and starters includes nonreversing and reversing contactors, overload relays and a variety of related accessories.
More informationBusbar Systems. Altech UL489. UL489 Listed Busbars. Universal UL489 Busbar fits most UL489 Miniature Circuit Breakers in the market!
Busbar Systems UL489 Listed Busbars The Altech Busbar System is an innovative way to jumper up to 57 poles of Miniature Circuit Breakers (MCB). The advantages of this busbar system are: 30% Installation
More informationHigh performance circuit breakers
Series High performance Description The high performance MCB offers a compact solution to circuit protection. The devices are DIN rail mounted. The is available with application-specific trip characteristics
More informationElectronic Timer Control Day Astronomic Electronic Control
Electronic Timer Control - 365-Day Astronomic Electronic Control Item ET90215CRE / EAN-Code PRODUCT DESCRIPTION The ET90000 Series combines powerful and intuitive scheduling with truly maintenance-free
More informationCT7N CT7 CT7K 4 6 CT TJ 4 6 CT7K TKK 6 10 CT TK 6 9 CT7K TKL
Obsolete Overload Cross Reference Series CT7/CT7K to Cross Reference CT7 CT7K Directly Mounts to Contactor... Adjustment Catalog Adjustment Catalog Adjustment Catalog Code Code Range (A) Number Range (A)
More informationGV2ME086 TeSys GV2 - Circuit breaker - thermal-magnetic A - lugs-ring terminals
Product data sheet Characteristics GV2ME086 TeSys GV2 - Circuit breaker - thermal-magnetic - 2.5...4 A - lugs-ring terminals Main Range Product name Device short name Device application Trip unit technology
More informationModular Lube Lubrication Systems System Controls
Model 84501 Program Timer Solid State Designed to control the lubrication cycle frequency of air-operated single-stroke pumps. Timer turns pump on/off at programmed intervals via a 3-way or 4-way air solenoid
More informationGV2ME. Main. Device short name. Device application
Product datasheet Characteristics GV2ME10 Main Range Product name Device short name Product or component type Device application Trip unit technology TeSys TeSys GV2 GV2ME Circuit breaker Motor Thermal-magnetic
More informationFeatures XT SC 012 B B A
Motor Control and Protection. XT IEC Manual and Combination Motor Controllers Selection XT IEC Manual and Combination Motor Controllers Manual and Combination Motor Controllers Design XT = XT IEC power
More information110 Volt AC at 50 Hertz, 120 Volt AC at 60 Hertz. 20 Amp (UL Continuous), 7 Amp (AC-3), 22 Amp (AC-1)
80 South Street 7596-726, TX Nacogdoches Phone: 96-569-79 Fax: 96-560-685 XTCE007B0A PH FVNR 7A IEC Contactor Eaton Corp Catalog Number XTCE007B0A Manufacturer Eaton Corp Description Magnetic Contactor,
More informationFeatures XT SC 012 B B A
Motor Control and Protection. XT IEC Manual and Combination Motor Controllers Selection XT IEC Manual and Combination Motor Controllers Manual and Combination Motor Controllers Design XT = XT IEC power
More informationData sheet. CI-TI TM Contactors and Motor Starters Contactors CI EI 520B1286
CI-TI TM Contactors and Motor Starters June 2002 DKACT.PD.C00.I2.02 520B1286 Introduction are intended for a.c. coil voltages and cover the power range 45-238 kw. The largest types, CI 170 EI-420 EI have
More information02/11/2015
DIN Rail Mount 17.5 mm MUS/MUSF 80 AC/DC Part number 84872141 Control relays monitoring their own power supply - MUS : Over/undervoltage control Selectable latching (memory) function - MUSF : Over/undervoltage
More information1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control
. XT Family of Contactors Contactors and Starters Product Description The Eaton XT contactors and starters includes nonreversing and reversing contactors, overload relays and a variety of related accessories.
More information1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control
. XT Family of Contactors Contactors and Starters Product Description The Eaton XT contactors and starters includes nonreversing and reversing contactors, overload relays and a variety of related accessories.
More informationKuhnke Technical Data. Contact Details
Kuhnke Technical Data The following page(s) are extracted from multi-page Kuhnke product catalogues or CDROMs and any page number shown is relevant to the original document. The PDF sheets here may have
More informationModular pulse operated latching relay 16 A
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 Modular pulse operated latc / 05 / 07 / 08 / 10 / 11 / 12 / 14 / 16 / 20 and 927 00 / 49 CONTENTS PAGES 1. Description,
More informationCatalogue numbers. PowerPact Multistandard. H-Frame, J-Frame unit-mount circuit breaker F-2. H-Frame, J-Frame circuit breaker accessories F-3
PowerPact Multistandard Catalogue numbers Functions and characteristics A-1 Installation recommendations B-1 Dimensions C-1 Wiring diagrams D-1 Additionals characteristics E-1 H-Frame, J-Frame unit-mount
More informationGV2P05. Main. Device short name. Device application
Product datasheet Characteristics GV2P05 Main Range Product name Device short name Product or component type Device application Trip unit technology TeSys TeSys GV2 GV2P Circuit breaker Motor Thermal-magnetic
More informationTeSys circuit-breakers
Thermal-magnetic motor circuit-breakers type GV2-ME GV2-ME with pushbutton control and screw clamp terminals (1) Standard power ratings Setting Magnetic Reference Weight of -phase motors range tripping
More informationDatasheet - SRB301LC 24VAC/DC
25.02.2016-18:05:23h Datasheet - SRB301LC 24VAC/DC Guard door monitors and Safety control modules for Emergency Stop applications / General Purpose safety controllers (Series PROTECT SRB) / SRB301LC Preferred
More informationAPPLICATIONS. Automatic warehouse. Trasportation lines
INDUCTIVE TUBULAR SENSOR M12 SERIES There are millions of inductive sensors deployed in almost every area of factory automation. They detect metal objects contactless and are distinguished by a long operating
More informationType Contact form Model Ag (Au clad) Standard DPDT G6A-274P-ST-US Low-sensitivity DPDT G6A-274P-ST40-US
Low Signal Relay G6A Fullly Sealed Relay with High Impulse Withstand High sensitivity can be driven by digital circuits. Low-profile design allows use in 12.70 mm PC board rack. Surge withstand meets FCC
More informationIntelligent compressor solutions. EFC, EFCe Systems Electronic Frequency Control EFC. EFCe
EFC, EFCe Systems Electronic Frequency Control Continuously variable speed control using frequency converter technology With the EFC and EFCe system Bock offers the most efficient means of adapting the
More information1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control
. XT Family of Contactors Contactors and Starters Product Description The Eaton XT contactors and starters includes nonreversing and reversing contactors, overload relays and a variety of related accessories.
More informationALLEN BRADLEY TIMING RELAY
ALLEN BRADLEY TIMING RELAY Configuration Details Product: 700-HS12BA1 Description: 700-HS General Purpose Square Base Timing Relay, On Delay Timer, 1.0 to 180 seconds, DPDT, 120V AC 50/60Hz CONTROL RELAY
More informationAltech UL489 Busbar System
Altech UL489 Busbar System ANNEX UL489 Listed Busbars The Altech Busbar System is an innovative way to jumper up to 57 poles of Miniature Molded Case (MMCCB). The advantages of this busbar system are:
More informationBulletin 109 TABLE OF CONTENTS Bulletin 109 IEC Non-Reversing Starters. Enclosed Type Molded Plastic. Description Page Description Page
3a Enclosed Type Molded Plastic Compact Design Impact-Resistant Molded Enclosures IP42 (Type 1) or IP66 (Type4/4X/12)Enclosure Ratings Solid-State Overload Relays Meets International Standards 109-C09KDA1E-1-4R1-7
More information59.1. Motor Control and Protection. For Immediate Delivery or Tech Support call KMParts.com at (866) Product Overview.
.1 Motor Control and Protection Product Overview Selection Guide Description Definite Purpose XT IEC Miniature XT IEC Page 65 Page 69 Page 71 Type Definite purpose IEC IEC Approvals UL Recognized, CSA,
More informationRCA3 SOLENOID PILOT VALVES PENTAIR CLEAN AIR SYSTEMS
RCA3 SOLENOID S PENTAIR CLEAN AIR SYSTEMS GOYEN RCA3D REMOTE PILOT Remote solenoid pilot valve to control the actuation of dust collector diaphragm valves. RCA3D with flying lead connection INSTALLATION
More informationDC Motors & Controls. DC2 DC Drives for 1/4 thru 2 Hp PMDC and Shunt Wound Motors. 1/4-2 Hp 115/230 VAC 1 Phase 50/60 Hz.
HVAC Farm Duty Brake 200 & 575 Volt & Controls DC 310 DC2 DC Drives for 1/4 thru 2 Hp PMDC and Shunt Wound DC & Controls 1/4-2 Hp 115/ 1 Phase 50/60 Hz. Applications: General purpose industrial use with
More informationGV3P80 TeSys GV3P thermal-magn motor circuit breaker 70-80A EverLink
Characteristics TeSys GV3P thermal-magn motor circuit breaker 70-80A EverLink Main Range Product name Device short name Product or component type Device application Trip unit technology Complementary Poles
More informationSingle Point Flow Monitor SW118 SW119
SW8 SW9 SW8 SW9 Single point flow monitors with MIN/MAX monitoring function, suitable for water, oil, air and media with similar thermal conductivities (selectable by means of a medium switch). With either
More informationType: NZMN1 A100 Article No.: Sales text Circuit breaker3p systems/cable prot. Ordering information Number of poles
Type: NZMN1 A100 Article No.: 259085 Sales text Circuit breaker3p systems/cable prot. Ordering information Number of poles Description Rated current = rated uninterrupted current Setting range 3 pole I
More informationEXPlora. Introduction
Introduction EXPlora The EXPlora range is most suited to manufacturers of ancillary electrical equipment such as motors, pumps, lighting equipment, process and control gear for use in factories and plant
More informationElectronic 2-Circuit 24-Hour Time Switch With 100-Hour Backup
MODELS ET2125C, ET2125CR, ET2125CP Installation and Setup Instructions Electronic 2-Circuit 24-Hour Time Switch With 100-Hour Backup WARNING Risk of Fire or Electric Shock Disconnect power at the circuit
More informationE6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm
Low-cost Encoder with Diameter of 50 mm CSM DS_E An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. High-precision detection of automatic machine timing.
More informationPROXIMITY SWITCHES INDUCTIVE TUBULAR SENSOR M30 SERIES HIGHLIGHTS APPLICATIONS
INDUCTIVE TUBULAR SENSOR M30 SERIES There are millions of inductive sensors deployed in almost every area of factory automation. They detect metal objects contactless and are distinguished by a long operating
More informationI r A I i = I n x. Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100
Deliveryprogramme Circuitbr.,3pmotorprotection Partno. Articleno. 265784 NZMN4-ME875 Product range Circuit-breaker Protective function Motor protection Standard/Approval IEC Installation type Fixed Release
More informationProduct Information. Circuit Breaker BZM1(16 to 125 A) Circuit Breaker BZM2 (125 to 250A) Circuit Breaker BZM3 (250 to 400A)
Circuit Breakers BZM Product Information Circuit Breaker BZM1(16 to 125 A) Circuit Breaker BZM2 (125 to 250A) Circuit Breaker BZM3 (250 to 400A) BZM1 & BZM2 & BZM3 Accessories Optimum and Efficient Protection
More informationBulletin 150, 154 Softstarters Quick Selection Table
Bulletin 50, 54 Quick Selection Table Type Current Range Bulletin No. 50 50 50 SMC-3 Controller 85 A SMC-Delta Controller 47 A SMC Flex Controller 54 480 A Soft Start Kickstart Current Limit Dual Ramp
More informationI r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100
DATASHEET - NZMH2-A100 Circuit-breaker, 3p, 100A Part no. NZMH2-A100 Catalog No. 259099 Similar to illustration Delivery program Product range Circuit-breaker Protective function System and cable protection
More informationGV2ME083 TeSys GV2 - Circuit breaker - thermal-magnetic A - spring terminals
Product datasheet Characteristics GV2ME083 TeSys GV2 - Circuit breaker - thermal-magnetic - 2.5...4 A - spring terminals Main Range Product name Device short name Product or component type Device application
More informationDescription Set value in neutral conductor is synchronous with set value Ir of main pole. R.m.s. value measurement and thermal memory CSA 100
DATASHEET - NZMN3-4-AE400 Circuit-breaker, 4p, 400A Part no. NZMN3-4-AE400 Catalog No. 265891 Similar to illustration EL-Nummer (Norway) 0004358857 Delivery program Product range Circuit-breaker Protective
More informationSelection guide siemens.com/sirius-modular-system
SIRIUS modular system Selection guide siemens.com/sirius-modular-system Everything for the control cabinet: SIRIUS modular system Efficiently combined Advantages at a glance: Load feeders: easy to implement
More informationOrdering details. Approval. Classification
Datasheet - SRB 301MC-24V Guard door monitors and Safety control modules for Emergency Stop applications / General Purpose safety controllers (Series PROTECT SRB) / SRB 301MC Fit for signal evaluation
More information