1 Yokogawa AC Voltage Switchboard Meters Click Here to Order Online AB Series Rugged, Durable Construction No Shadows on Scale Accurate and Readable, Even from Sharp Angles Accurate to Within ±1% of Full Scale Attractive, Uncluttered Scales High-Shock Design Meets MIL-M-16034A and MIL-S-901 (AB-14) Weathertight Construction Ideal for Adverse Conditions (AB-40) Easy to Read Up to 30 Feet Away (AB-16) Taut-Band Suspension ORDERING INFORMATION Self-Contained, 50/60 Hz Rating Scale AB-14 AB-40 AB-16 (volts) Volts Cat. No. Cat. No. Cat. No PZPZ PZPZ PZPZ RSRS RSRS RSRS RXRX RXRX RXRX SFSF SFSF SFSF SJS SJSJ SJSJ 750* 0-750* ** SMSM SMSM Transformer-Rated, 50/60 Hz PZRX PZRX PZRX PZSJ PZSJ PZSJ PZSM PZSM PZSM PZUA PZUA PZUA PZUL PZUL PZUL PZUY PZUY PZUY kV PZWZ PZWZ PZWZ kV PZXE PZXE PZXE kV PZXU PZXU PZXU kV PZYR PZYR PZYR RSSJ RSS RSSJ Expanded Scale Self-Contained, 50/60 Hz ** PNPN PNPN Expanded Scale Transformer-Rated, 50/60 Hz ** PN PN..+ Rectifier-Type 1.5% Hz ** ** ** ** ** ** + + Ground-Detector Type-Single-Phase 50/60 Hz ** PZPZ PZPZ ** PZ PZ ** RXRX RXRX ** SJSJ SJSJ AB-40 Photos not to scale SPECIFICATIONS OPTIONS Custom Scaling Nonstandard Ranges Adjustable Potentiometer (Voltmeters Only) Color Bands AB-16 In accordance with ANSI Specifications C39.1 Accuracy ±1% of FS basic accuracy class Rectifier Instruments ± C calibrated on sine wave Operating Temperature Range 0 40 C (32 F 104 F) Dielectric Level 2,300VAC for 1 minute between circuit & case Overload Rating Voltmeter or potential coils 1.2x continuous; AC ammeters 2x continuous, 10x for 1 second; Current coils other than AC ammeters 1.5x continuous, 10x for 1 second Response Time Approx. 2.5 seconds (except AB-16) Position of Use Vertical (scale) Full Scale Deflection Angle 250 Case Size 4 1 4" 4 1 4" 8 3 4" Model AB-14 AB-40 AB-16 Size (H x W x D) 4.33" x 4.33" x 4.85" 8.69" x 8.69" x 4.85" Barrel (cutout) 4.03" Full Scale Length 6.9" 13.8" * UL Version Not Available ** High Stock Version Not Available + Order by Description. Specify P.T. (Potential Transformer) Ratio if Used, and Scale Desired. AB fax: info@weschler.com 52

2 Yokogawa AC Watt & VAR Switchboard Meters Click Here to Order Online 53 Rugged, Durable Construction No Shadows on Scale Accurate and Readable, Even from Sharp Angles Accurate to Within ±1% of Full Scale Attractive, Uncluttered Scales Weathertight Construction Ideal for Adverse Conditions (AB-40) Easy to Read Up to 30 Feet Away (AB-16) Taut-Band Suspension SPECIFICATIONS In accordance with ANSI Specifications C39.1 Accuracy ±1% of FS basic accuracy class Rectifier Instruments ± C calibrated on sine wave Operating Temperature Range 0 40 C (32 F 104 F) Dielectric Level 2,300VAC for 1 minute between circuit & case Overload Rating Voltmeter or potential coils 1.2x continuous; AC ammeters 2x continuous, 10x for 1 second; Current coils other than AC ammeters 1.5x continuous, 10x for 1 second Response Time Approx. 2.5 seconds (except AB-16) Position of Use Vertical (scale) Full Scale Deflection Angle 250 (360 for synchr scopes) Case Size 4 1 4" 8 3 4" Model AB-40 AB-16 Size (H x W x D) 4.33" x 4.33" x 4.85" 8.69" x 8.69" x 4.85" Barrel (cutout) 4.03" Full Scale Length 6.9" 13.8" VAR METER ORDERING INFORMATION Rating (Amperes) Rating (Volts) Scale AB-40 Cat. No. AB-16 Cat. No. Single Phase/2-Wire, 1-Element, Transformer Rated, 60 Hz A A A * A * 3-Phase/3-Wire, 2-Element, Transformer Rated, 50/60 Hz (Cannot Use with External Phase Shifter) A A A A 3-Phase, 3-Wire, 2-Element, Transformer-Rated, 60 Hz for Use with External Phase Shifters A A A * A * 3-Phase/4-Wire, Element, Transformer-Rated, 50/60 Hz (Cannot Use External Phase Shifter) B B B B 3-Phase/4-Wire, Element, Transformer-Rated, 60 Hz for Use with External Phase Shifters A A A * A * Order by description. Specify CT (Current Transformer) and/or PT (Potential Transformer) ratios if used and scale desired. * Used for 0-Center when calibrating watts are less than ±380. Used for 0-Center when calibrating watts less than ±658. Used for 0-Center when calibrating watts are less than ±760. The element varmeters used on 4-wire 3-phase 120V L-N systems are rated 208V because they are connected line-to-line. Sixth digit signifies pointer deflection (1-zero left, 2-zero center). Photos not to scale AB-40 AB-16 AC Wattmeters Non-Isolated (cannot be use with external phase shifter for VARs) Single-Phase/2-Wire, 1-Element, Self-Contained, 50/60 Hz Rating Scale AB-40 AB-16 Amperes/Volts Cat. No. Cat. No Watts AARC7GCB AARC7GCB Watts AAWP7CJB AAWP7CJB Watts ARBU7CRB ARBU7CRB Watts AWDP7DAB AWDP7DAB Single-Phase/2-Wire, 1-Element, Transformer-Rated, 50/60 Hz A A 3-Phase/3-Wire, 2-Element, Transformer-Rated, 50/60 Hz A A C C 5 480* D D 5 600* E E 3-Phase/4-Wire, Element, Transformer-Rated, 50/60 Hz (voltage balanced) F F A A C C + Order by Description. Specify CT (Current Transformer) and/or PT (Potential Transformer) Ratios if Used, and Scale Desired. * UL Version in Short Case, Non-UL Version in Long Case. Sixth Digit Signifies Pointer Deflection (1-Zero Left, 2-Zero Center) Custom Scaling Nonstandard Ranges Zero-Center Color Bands Nonstandard Frequencies fax: info@weschler.com WATT METER ORDERING INFORMATION OPTIONS (WHERE APPLICABLE)

3 Yokogawa Power Factor, Frequency & Synchroscope Meters Rugged, Durable Construction Click Here to Order Online No Shadows on Scale Accurate and Readable, Even from Sharp Angles Accurate to Within ±1% of Full Scale Attractive, Uncluttered Scales Weathertight Construction Ideal for Adverse Conditions (AB-40) Easy to Read up to 30 Feet Away Taut-Band Suspension Except Synchroscopes AB-16 ORDERING INFORMATION Power Factor AB-40 AB-16 Amperes Volts Scale Cat. No. Cat. No. Single-Phase 2 Wire 60 Hz FCAD FCAD 3-Phase 3 & 4 Wire, 50 & 60 Hz, Balanced System Only FCAD FCAD 5 208* CCAD CCAD FEAD FEAD FFAD FFAD FGAD FGAD 3-Phase 3 Wire, 50/60 Hz, Unbalanced Systems FCAD FEAD 3-Phase 4-Wire, 50/60 Hz, Unbalanced Systems FCAD CCAD FEAD Frequency Meters, 120V Rated Scale Center AB-40 AB-16 (Hz) Freq, Hz Cat. No. Cat. No AGAG AGAG AJAJ AJAJ AKAK AKAK ALAL ALAL ANAN ANAN ATAT ATAT ASAS ASAS BHBH BHBH BLBL BLBL Synchroscopes Pivot and Jewel 120 Volt Rated Scale Normal AB-40 AB-16 Freq. Cat. No. Cat. No. Slow-Fast ABAA ABAA Slow-Fast AAAA AAAA Slow-Fast ACAA ACAA * Line to line 208V (120V line to neutral) + Line to line ++ Line to neutral AB-40 In accordance with ANSI Specifications C39.1 Accuracy ±1% of FS basic accuracy class Rectifier Instruments ± C calibrated on sine wave Power Factor Meters ±1% of scale length Balanced system (20-100% rated current) Unbalanced system (±3% of scale length) Frequency Meters 45 Hz 55 Hz, ±0.15 Hz 55 Hz 66 Hz, ±0.15 Hz 58 Hz 62 Hz, ±0.093 Hz 350 Hz 450 Hz, ±1.5 Hz Operating Temperature Range 0 40 C (32 F 104 F) Dielectric Level 2,300 VAC for 1 minute between circuit and case Overload Rating Voltmeter or potential coils, 1.2x continuous AC ammeters, 2x continuous, 10x for 1 second. Current coils other than AC ammeters, 1.5x continuous, 10x for 1 second Response Time Approx. 2.5 seconds (except AB/DB-16) Position of Use Vertical (scale) Full Scale Deflection Angle 250 Case Size Model Size (H x W x D) Barrel (Cutout) Scale Length 4 1 4" AB " x 4.33" x 6.75" 4.03" 6.9" 4 1 4" AB " x 4.33" x 6.75" 4.03" 6.9" 8 3 4" AB " x 8.69" x 6.75" 4.03" 13.8" fax: info@weschler.com SPECIFICATIONS 54

4 250 Linear Scale AC Instruments with True RMS Circuit UL/CSA Approvals Oil Dampened Mechanisms AC/DC SWITCHBOARD METER SPECIFICATIONS Accuracy: ±1% Full Scale Response Time: Approx. 2.5 Seconds to Full Scale Scale Arc: 250 Full Scale Deflection Position Use: Vertical (Scale) Overshoot: 33% Maximum Dielectric Withstand: 2300 VAC for 1 Minute Operating Temperature: -20 C to 65 C Size (H x W x D): 4.30" x 4.30" x 2.20" AC AMMETERS - RMS READING SELF CONTAINED 4 1 /2" Square Flange 1A 0-1A -05FA-LALA-C FJ-LALA-C6 1.5A 0-1.5A -05FA-LCLC-C FJ-LCLC-C6 2A 0-2A -05FA-LELE-C FJ-LELE-C6 3A 0-3A -05FA-LJLJ-C FJ-LJLJ-C6 5A 0-5A -05FA-LSLS-C FJ-LSLS-C6 7.5A 0-7.5A -05FA-MFMF-C FJ-MFMF-C6 10A 0-10A -05FA-MTMT-C FJ-MTMT-C6 15A 0-15A -05FA-NDND-C FJ-NDND-C6 20A 0-20A -05FA-NGNG-C FJ-NGNG-C6 30A 0-30A -05FA-NLNL-C FJ-NLNL-C6 AC AMMETERS - RMS READING TRANSFORMER RATED 5A 0-10A -05FA-LSMT-C FJ-LSMT-C6 5A 0-15A -05FA-LSND-C FJ-LSND-C6 5A 0-20A -05FA-LSNG-C FJ-LSNG-C6 5A 0-25A -05FA-LSNJ-C FJ-LSNJ-C6 5A 0-30A -05FA-LSNL-C FJ-LSNL-C6 5A 0-40A -05FA-LSNP-C FJ-LSNP-C6 5A 0-50A -05FA-LSNT-C FJ-LSNT-C6 5A 0-75A -05FA-LSPB-C FJ-LSPB-C6 5A 0-100A -05FA-LSPK-C FJ-LSPK-C6 5A 0-150A -05FA-LSPZ-C FJ-LSPZ-C6 5A 0-200A -05FA-LSRL-C FJ-LSRL-C6 5A 0-250A -05FA-LSRS-C FJ-LSRS-C6 5A 0-300A -05FA-LSRX-C FJ-LSRX-C6 5A 0-400A -05FA-LSSC-C FJ-LSSC-C6 5A 0-500A -05FA-LSSF-C FJ-LSSF-C6 Note: Additional meters with scales up to 8,000A available AC VOLTMETERS- RMS READING SELF CONTAINED 4 1 /2" Square Flange 150V 0-150V -05GA-PZPZ-C GJ-PZPZ-C6 250V 0-250V -05GA-RSRS-C GJ-RSRS-C6 300V 0-300V -05GA-RXRX-C GJ-RXRX-C6 500V 0-500V -05GA-SFSF-C GJ-SFSF-C6 600V 0-600V -05GA-SJSJ-C GJ-SJSJ-C6 750V 0-750V -05GA-SMSM-C GJ-SMSM-C6 AC VOLTMETERS - RMS READING TRANSFORMER RATED 150V 0-300V -05GA-PZRX-C GJ-PZRX-C6 150V 0-600V -05GA-PZSJ-C GJ-PZSJ-C6 150V 0-750V -05GA-PZSM-C GJ-PZSM-C6 150V V -05GA-PZUA-C GJ-PZUA-C6 150V V -05GA-PZUL-C GJ-PZUL-C6 150V V -05GA-PZUP-C GJ-PZUP-C6 150V V -05GA-PZUY-C GJ-PZUY-C6 150V 0-15 KV -05GA-PZWC-C GJA-PZWC-C6 150V 0-18 KV -05GA-PZWD-C GJ-PZWD-C6 150V 0-45 KV -05GA-PZWJ-C GJ-PZWJ-C6 250V 0-600V -05GA-RSSJ-C GJ-RSSJ-C6 55 FREQUENCY METERS 120V SELF CONTAINED Standard Case Hi-Shock Case Center Frequency Accuracy Hz Scale Catalog Number Catalog Number 50 Hz ± Hz -41LA-PNAG-AG LJ-PNAG-AG 50 Hz ± Hz -41LA-PNAH-AH LJ-PNAH-AH 50 Hz ± Hz -41LA-PNAJ-AJ LJ-PNAJ-AJ 60 Hz ± Hz -41LA-PNAL-AL LJ-PNAL-AL 60 Hz ± Hz -41LA-PNAN-AN LJ-PNAN-AN 60 Hz ± Hz -41A-PNAO-AO LJ-PNAO-AO 60 Hz ± Hz -41A-PNAT-AT LJ-PNAT-AT fax: info@weschler.com

5 DC AMMETERS - SELF CONTAINED 200 ua ua -05AA-EAEA AJ-EAEA 300 ua ua -05AA-EEEE AA-EEEE 500 ua ua -05AA-EMEM AA-EMEM 800 ua ua -05AA-EWEW AA-EWEW 1 ma 0-1 ma -05AA-FAFA AA-FAFA 2 ma 0-2 ma -05AA-FGFG AA-FGFG 5 ma 0-5 ma -05AA-FXFX AA-FXFX 10 ma 0-10 ma -05AA-GZGZ AA-GZGZ 20 ma 0-20 ma -05AA-HFHF AA-HFHF 30 ma 0-30 ma -05AA-HMHM AA-HMHM 50 ma 0-50 ma -05AA-HYHY AA-HYHY 100 ma ma -05AA-JRJR AA-JRJR 200 ma ma -05AA-KAKA AA-KAKA 300 ma ma -05AA-KGKG AA-KGKG 500 ma ma -05AA-KMKM AA-KMKM 800 ma ma -05AA-KWKW AA-KWKW 1A 0-1A -05AA-LALA AA-LALA 5A 0-5A -05AA-LSLS AA-LSLS 10A 0-10A -05AA-MTMT AA-MTMT 15A 0-15A -05AA-NDND AA-NDND 20A 0-20A -05AA-NGNG AA-NGNG 30A 0-30A -05AA-NLNL AA-NLNL 50 mv 0-15A -05AA-EYND AJ-EYND 50 mv 0-20A -05AA-EYNG AJ-EYNG 50 mv 0-30A -05AA-EYNL AJ-EYNL 50 mv 0-40A -05AA-EYNP AJ-EYNP 50 mv 0-50A -05AA-EYNT AJ-EYNT 50 mv 0-75A -05AA-EYPB AJ-EYPB 50 mv 0-100A -05AA-EYPK AJ-EYPK 50 mv 0-150A -05AA-EYPZ AJ-EYPZ 50 mv 0-200A -05AA-EYRL AJ-EYRL 50 mv 0-300A -05AA-EYRX AJ-EYRX 50 mv 0-400A -05AA-EYSC AJ-EYSC 50 mv 0-500A -05AA-EYSF AJ-EYSF 50 mv 0-750A -05AA-EYSM AJ-EYSM 50 mv A -05AA-EYSS AJ-EYSS 50 mv A -05AA-EYSU AJ-EYSU 50 mv A -05AA-EYTC AJ-EYTC 50 mv A -05AA-EYTM AJ-EYTM 50 mv A -05AA-EYUA AJ-EYUA DC AMMETERS - SHUNT RATED 1/5 ma To Suit 4/20 ma To Suit 10/50 ma To Suit MILLIAMMETERS = SUPPRESSED ZERO 15V 0-15V -05VA-NDND VJ-NDND 30V 0-30V -05VA-NLNL VJ-NLNL 50V 0-50V -05VA-NTNT VJ-NTNT 75V 0-75V -05VA-PBPB VJ-PBPB 150V 0-150V -05VA-PZPZ VJ-PZPZ 300V 0-300V -05VA-RXRX VJ-RXRX 400V 0-400V -05VA-SCSC VJ-SCSC 500V 0-500V -05VA-SFSF VJ-SFSF 600V 0-600V -05VA-SJSJ VJ-SJSJ 750V 0-750V -05VA-SMSM VJ-SMSM 800V 0-800V -05VA-SNSN VJ-SNSN DC VOLTMETERS (SENSITIVITY 1000 OHMS PER VOLTS) Standard Case Hi-Shock Case Rating &Scale Catalog Number Catalog Number V -05NA-RXRX NJ-RXRX V -05NA-SJSJ NJ-SJSJ V -05NA-SSSS NJ-SSSS V -05NA-SUSU NJ-SUSU DC VOLTMETERS - ZERO CENTER (2000 OHMS PER VOLT) fax: info@weschler.com 56

6 AC VARMETERS Phase/ Amp/ 2 element, transformer rated, 50/60 Hz, Taut Band, integral transducer 3 / 3 5/120 To Suit + -31LA-QQ** LJ-QQ** 3 / 3 5/208 To Suit 31LA-QR** LJ-QR** 3 / 3 5/240 To Suit -31LA-QS** LJ-QS** 3 / 3 5/380 To Suit -31LA-QX** LJ-QX** 3 / 3 5/480 To Suit -31LA-QT** LJ-QT** 3 / 3 5/600 To Suit -31LA-VY** LJ-VY** Use 077 for 4 1 2" Case and 079 for 8 1 2" Case ** Specify Current Transformer and Voltage Transformer and Preferred Scale element, transformer rated, 50/60 Hz, Taut Band, integral transducer 3 / 4 5/120 To Suit + -31UA-QL** UJ-QL** 3 / 4 5/208 To Suit -31UA-QR** UJ-QR** 3 / 4 5/480 To Suit -31UA-QT** UJ-QT** 3 / 4 5/600 To Suit -31UA-VY** UJ-VY** ** Specify Current Transformer and Voltage Transformer and Preferred Scale UL Recognized and CSA Approved, 079 UL Recognized 57 AC WATTMETER AND VARMETER SPECIFICATIONS Burden per element: Current Circuit: 2 VA Voltage Circuit: 1 VA Accuracy Class: 1.0 Scale Arc: 250 Full Scale Deflection Position Use: Vertical (Scale) Overshoot: 33% Maximum Dielectric Withstand: 2600 VRMS for 1 minute Operating Temperature: 0 to 60 C (32 to 140 F) Size (H x W x D): 4.30" x 4.30" x 5.19" AC WATTMETERS Phase/ Amp/ 1 element, transformer rated, 50/60 Hz, Taut Band, integral transducer 1 / 2 5/120 To Suit A-QQ** J-QQ** 1 / 2 5/120 To Suit -215A-QQ** J-QQ** 2 element, transformer rated, 50/60 Hz, Taut Band, integral transducer 3 / 3 5/120 To Suit A-QQ** J-QQ** 3 / 3 5/208 To Suit -218A-QR** J-QR** 3 / 3 5/240 To Suit -218A-QS** J-QS** 3 / 3 5/380 To Suit -218A-QX** J-QX** 3 / 3 5/480 To Suit -218A-QT** J-QT** 3 / 3 5/600 To Suit -218A-QY** J-QY** element, transformer rated, 50/60 Hz, Taut Band, integral transducer 3 / 4 5/69 To Suit A-QL** J-QL** 3 / 4 5/120 To Suit A-QQ** J-QQ** 3 / 4 5/277 To Suit -219A-QY** J-QY** 3 / 4 5/346 To Suit -219A-QZ** J-QZ** ** Specify Current Transformer and Voltage Transformer and Preferred Scale UL Recognized and CSA Approved, 079 UL Recognized A Phase/ Amp/ Single element, transformer rated, 50/60 Hz, Taut Band, integral transducer 1 / 2 5 / 120 To Suit 077-KHBU-QQ** 077-KHBJ-QQ** 2 element, transformer rated, 50/60 Hz, Taut Band, integral transducer 3 / 3 5 / 120 To Suit 077-KHEU-QQ** 078-KHEU-QQ** 3 / 3 5 / 208 To Suit 077-KHEU-QR** 078-KHEU-QR** element, transformer rated, 50/60 Hz, Taut Band, integral transducer 3 / 4 5 / 69 To Suit 077-KHGU-QL** 078-KHGU-QL** 3 / 4 5 / 120 To Suit 077-KHEU-QQ** 078-KHEU-QQ** 3 / 4 5 / 277 To Suit 077-KHGU-QY** 078-KHGU-QY** ** - Specify pulse rate and external power supply AC SYNCHROSCOPES - PIVOT AND JEWEL KH AC WATT/WATT HOUR METERS (SELF CONTAINED) Volts Hz Scale Catalog Number Catalog Number 120V 50 Hz SLOW FAST A-PRAE-C J-QQAB-C5 120V 60 Hz SLOW FAST A-PRAE-C J-QQAB-C5 120V 400 Hz SLOW FAST A-PRAE-C J-QQAB-C UL Recognized and CSA Approved, 079 UL Recognized AC LED 360 SYNCHROSCOPES Standard Case Volts Hz Scale Catalog Number 120V 40/65 Hz SLOW FAST AU-PQYY-FQ 240V 40/65 Hz SLOW FAST AU-RRYY-FQ 480V 40/65 Hz SLOW FAST AU-SEYY-FQ fax: info@weschler.com

7 Rugged taut bank construction 3 1 /2 digit LED display Wide selection of inputs Standard ANSI 4 1 /2" switchboard mounting 077-DI PHASE SHIFTING TRANSFORMERS For use with Wattmeters, when VAR measurement with external phase shifter is required Phase/ Amp/ 3 / 3 120V To Suit -956-A-PR J-PR 3 / 4 120V To Suit -957-A-PR J-PR 3 / 4 69V To Suit -956-A-NZ J-NZ Use 855 for 4 1 2" or 8 3 4" Case AC POWER FACTOR METERS (BALANCED LOAD) Phase/ Amp/ 1 / 2 5/ A-QQAD J-QQAD 1 / 2 5/ A-QSAD J-QSAD 3 / 3 or 4 5/ A-QQAD J-QQAD 3 / 3 or 4 5/ A-QRAD J-QRAD 3 / 3 or 4 5/ A-QSAD J-QSAD 3 / 3 or 4 5/ A-QTAD J-QTAD 3 / 3 or 4 5/ A-QVAD J-QVAD Use 077 for 4 1 2" Case and 079 for 8 1 2" Case UL Recognized and CSA Approved, 079 UL Recognized AC POWER FACTOR METERS (UNBALANCED LOAD) Phase/ Amp/ 3 / 3 5/ TFUA-QQAD N/A 3 / 3 5/ TFUA-QQAD N/A AC POWER FACTOR METERS ROTATING IRON Phase/ Amp/ 3 / 3 or 4 5/ A-QQAB J-QQAB 3 / 3 or 4 5/ A-QRAB J-QQAB 3 / 3 5/ A-QQAB J-QQAB 3 / 3 5/ A-QRAB J-QQAB AC AMMETERS TRANSFORMER RATED (40/2000Hz) Digital accuracy ±0.1% ±1 counts, analog accuracy ±1%. 5A 0-20A 077-DIBA-LSNG-C6-** 5A 0-50A 077-DIBA-LSNT-C6-** 5A 0-100A 077-DIBA-LSPK-C6-** 5A 0-300A 077-DIBA-LSRX-C6-** 5A 0-400A 077-DIBA-LSSC-C6-** 5A 0-500A 077-DIBA-LSSF-C6-** 5A A 077-DIBA-LSTC-C6-** Direct reading AC Ammeters also available, 1A to 10A. AC VOLTMETERS TRANSFORMER RATED (40/2000HZ) 150V 0-300V 077-DIWA-PZRX-C6-** 150V 0-600V 077-DIWA-PZSJ-C6-** 150V 0-750V 077-DIWA-PZSM-C6-** 150V V 077-DIWA-PZUA-C6-** 150V V 077-DIWA-PZUP-C6-** Direct reading AC Voltmeters also available, 200mV to 600V. AC FREQUENCY METERS Self contained 110/130 Volt rating. Integral transducer Center Accuracy Scaling* Catalog No. 50Hz ± Hz 077-DZLA-PNAG-AG 55Hz ± Hz 077-DZLA-PNAJ-AJ 60Hz ± Hz 077-DZLA-PNAL-AL 60Hz ± Hz 077-DZLA-PNAN-AN 400Hz ± Hz 077-DZLA-PNBI-BI Direct reading AC Ammeters also available, 1A to 10A. DC VOLTMETERS - DIRECT READING Digital accuracy ±0.5% ±1 counts, analog accuracy ±1%. 200mV 0-200mV 077-DIVA-KAKA-** 1V 0-1V 077-DIVA-LALA-** 5V 0-5V 077-DIVA-LSLS-** 50V 0-50V 077-DIVA-NTNT-** 150V 0-150V 077-DIVA-PZPZ-** 300V 0-300V 077-DIVA-RXRX-** DC AMMETERS DIRECT READING Digital accuracy ±0.5% ±1 counts, analog accuracy ±1%. 1mA 0-1mA 077-DIAA-FAFA-** 10mA 0-10mA 077-DIAA-GZGZ-** 20mA 0-20mA 077-DIAA-HFHF-** 100mA 0-100mA 077-DIAA-JRJR-** 1A 0-1A 077-DIAA-LALA-** MU 12 Volts DC BD 24 Volts DC NR 48 Volts DC PR 120 Volts DC PS 125 Volts DC Z2 130 Volts DC ** POWER SUPPLY PO 115 Volts AC PQ 120 Volts AC RR 240 Volts AC Many standard ranges not shown. *Custom scales and custom ranges on request fax: info@weschler.com 58

Crompton Switchboard Meters

Crompton Switchboard Meters Crompton Switchboard Meters 250 Linear Scale AC Instruments with True RMS Circuit Rugged Pivot & Jewel Movement IP54 Front cul & CE Certifications ANSI C39.1 Performance Terminal Cover (007 Case) AC/DC

More information

Weschler Analog Switchboard Meters

Weschler Analog Switchboard Meters Weschler Analog Switchboard Meters High accuracy, full view design Volts, amps, watts, vars, speed, frequency and power factor High overload capacity Military and Nuclear versions Ultimate in reliability

More information

30 STYLE LISTINGS SWITCHBOARD METERS

30 STYLE LISTINGS SWITCHBOARD METERS 30 STYLE LISTINGS SWITCHBOARD METERS Dc Circular Scale Dc Edgewise Type... Size... Scale Arc... Standard Specification... Accuracy Class... KX-261 MIL-M-16034A VX-252 HX-252 Dc Microammeter seif-contained

More information

ANALOGUE METERS FOR MARINE APPLICATIONS

ANALOGUE METERS FOR MARINE APPLICATIONS CROMPTON INSTRUMENTS ANALOGUE METERS FOR MARINE APPLICATIONS ANALOGUE INSTRUMENTS FOR MARINE APPLICATIONS High quality analogue instruments designed to measure a wide range of electrical parameters. This

More information

Product Guide. Analog Panel Meters for use in Electrical Engineering Systems. M Series. Instruments clamping to 35 mm DIN rails W/P/ LSP BWQ BGQ

Product Guide. Analog Panel Meters for use in Electrical Engineering Systems. M Series. Instruments clamping to 35 mm DIN rails W/P/ LSP BWQ BGQ Product Guide Analog Panel Meters for use in Electrical Engineering Systems M Series 200.U.001.05 M Series W/P/ LSP Instruments clamping to 35 mm DIN rails BWQ BGQ TP TG WQ /0S WQ /2S FQ /2 W BI BIW SY

More information

Measurement and Instrumentation

Measurement and Instrumentation Measurement and instrumentation Overview of ranges Selection guide Info & advice Round barrel NORMEUROPE range High-level operating constraints Square barrel LOGIC range Standard applications and products

More information

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell 99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load

More information

ORDERING Page 6 BASLER RELAY STANDARDS, DIMENSIONS, ACCESSORIES Request bulletin SDA

ORDERING Page 6 BASLER RELAY STANDARDS, DIMENSIONS, ACCESSORIES Request bulletin SDA BE1-59NC CAPACITOR NEUTRAL OVERVOLTAGE RELAY The BE1-59NC Capacitor Neutral Overvoltage Relay provides sensitive protection for capacitor banks. ADDITIONAL INFORMATION INSTRUCTION MANUAL ADVANTAGES Helps

More information

ORDERING Page 6 STANDARDS, DIMENSIONS and ACCESSORIES Request bulletin SDA

ORDERING Page 6 STANDARDS, DIMENSIONS and ACCESSORIES Request bulletin SDA BE1-59NC CAPACITOR NEUTRAL OVERVOLTAGE RELAY The BE1-59NC Capacitor Neutral Overvoltage Relay provides sensitive protection for capacitor banks. ADVANTAGES Helps avoid cascading capacitor failures. Sensing

More information

Type Contact form Model PCB SPDT G6E-134P-ST-US G6E-134PL-ST-US. Type Contact form Model

Type Contact form Model PCB SPDT G6E-134P-ST-US G6E-134PL-ST-US. Type Contact form Model Low Signal Relay G6E Subminiature 7.87 H x.1 W x 16 L mm (0.31 H x 0.3 W x 0.63 L in). High sensitivity with pick-up coil power of 8 mw. Surge withstand meets FCC Part 68 rule and Telcordia 2.5 kv Specifications.

More information

3.5. Control Relays and Timers. Contents. 9575H Series 3000 Type AA, AC and DC. General Purpose Relays Type AA

3.5. Control Relays and Timers. Contents. 9575H Series 3000 Type AA, AC and DC. General Purpose Relays Type AA .5 9575H Series 000 Relay Contents 9575H Series 000 Type AA, AC and DC Product Selection....................... Accessories............................ Technical Data and Specifications........... Dimensions............................

More information

Type Contact form Model

Type Contact form Model Low Signal Relay G6A High sensitivity can be driven by digital circuits. Low-profile design allows use in.70 mm (0.50 in) PC board rack. Surge withstand meets FCC Part 68 regulation. Units can be mounted

More information

TESTING METHODS AND RELIABILITY -POWER

TESTING METHODS AND RELIABILITY -POWER TESTING METHODS AND RELIABILITY -POWER By the same author Testing Methods and Reliability - Electronics Macmillan Basis Books in Electronics Electrical Circuits and Systems Noel M. Morris Digital Electronic

More information

DUCATI SISTEMI S. P. A. DUCA47-96 USER MANUAL

DUCATI SISTEMI S. P. A. DUCA47-96 USER MANUAL DUCATI SISTEMI S. P. A. DUCA47-96 USER MANUAL Introduction The instrument DUCA47-96 is a digital multimeter for panel mounting that allows the measurement of the principal electrical parameters in three-phase

More information

ScopeMeter 190 Series Specifications

ScopeMeter 190 Series Specifications Seite 1 von 7 ScopeMeter 190 Series Specifications Product Home Features Specifications Models, Options & Accessories Oscilloscope Mode Meter Mode Recorder Mode General Specifications Oscilloscope Mode

More information

GP-500 SERIES - Low Voltage

GP-500 SERIES - Low Voltage M O T O R & G E N E R A T O R P R O T E C T I O N AUTOMATIC INSULATION RESISTANCE TESTERS Meg-Alert is an automatic, in-line insulation resistance tester and monitor with test capabilities from 500 to

More information

SECTION 8. Counters & Timers. Laurel Hecon Simpson Yokogawa (YCA)

SECTION 8. Counters & Timers. Laurel Hecon Simpson Yokogawa (YCA) SECTION Counters & Timers (Analog / Digital) Laurel Hecon Simpson Yokogawa (YCA) Counters and Timers from the following manufacuturers are also available but not shown in catalog: Texmate Triplett (LFE)

More information

USER MANUAL. Compact dimensions 6 DIN modules, with 4 LED s display with 7 segments, for an excellent reading of the measurements

USER MANUAL. Compact dimensions 6 DIN modules, with 4 LED s display with 7 segments, for an excellent reading of the measurements DUCATI SISTEMI S. P. A. DUCA47 USER MANUAL Introduction The instrument DUCA47 is a digital multimeter that allows the measurement of the principal electrical parameters in threephase 230/400Vac networks

More information

Analog Panel Meters Preference Program Basic Series Vario Series

Analog Panel Meters Preference Program Basic Series Vario Series Analog Panel Meters Preference Program Basic Series Vario Series Analog Panel Meters Preference Program Certificates DIN EN ISO 9001:2000 - Certificate Germanischer Lloyd - Certificates Square Panel Meters

More information

9 Control Equipment. Measurement- and Control Equipment Series 8214, 8218

9 Control Equipment. Measurement- and Control Equipment Series 8214, 8218 9 Control Equipment Measurement- and Control Equipment Series, Explosion protection to CENELEC IEC Can be used in Zone 1 and Zone 2 Designed for panel mounting Enclosure material : Polyester resin : Aluminium,

More information

LAUREL ELECTRONICS, INC.

LAUREL ELECTRONICS, INC. LAUREL ELECTRONICS, INC. Laureate Digital Panel Meter for Process, Strain & Potentiometer Follower Signals Features Selectable ±0.2, ±2, ±20, ±200, ±300 & ±600 Vdc voltage ranges Selectable ±2, ±20, ±200

More information

MILLITARY SPECIFICATION SHEET

MILLITARY SPECIFICATION SHEET INCH-POUND MILLITARY SPECIFICATION SHEET 10 November 2000 SUPERSEDING MIL-R-6106/14B 10 March 1989 RELAY, ELECTRIC, PERMANENT DRIVE, 50 AMP, SPDT (DB) DOUBLE MAKE DOUBLE BREAK AUXILIARY CONTACTS (5 AMP),

More information

MIL-C CLASS L COMPATIBILITY ORDERING INFORMATION

MIL-C CLASS L COMPATIBILITY ORDERING INFORMATION MIL-C-22992 CLASS L COMPATIBILITY ORDERING INFORMATION ORDERING INFORMATION: Connectors are supplied with removable contacts. Contacts are supplied unassembled. Also supplied are applicable accessories

More information

SCALE & WEIGHT DISPLAYS

SCALE & WEIGHT DISPLAYS The MICRO SERIES SCALE & WEIGHT DISPLAYS LARGE DIGIT MODELS Mighty-5S DPM MODELS Micro-S & Mighty-1S Mighty-1S Micro-S ELECTRO-NUMERICS, INC. Introduction The Electro-Numerics family of Digital Panel Meters

More information

multi-function meters

multi-function meters multi-function meters eclipse 2 eclipse 7 installation and operating manual 1 GENERAL DESCRIPTION 2 INSTALLATION 3 WIRING INFORMATION 4 2 ECLIPSE 2 METERS 2.1 PROGRAMMING THE METER 5 2.2 INFORMATION 6

More information

BE3-GPR GENERATOR PROTECTIVE RELAY

BE3-GPR GENERATOR PROTECTIVE RELAY BE3-GPR GENERATOR PROTECTIVE RELAY Behind-the-Panel Mounting Semi-flush Mounting Basler Electric s BE3-GPR generator protective relay offers multiple protective features in a single package. Its microprocessor-based

More information

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description Description LAUREL ELECTRONICS, INC. Features Laureate Digital Panel Meter for Load Cell & Microvolt Input 20, 50, 100, 250 & 500 mv ranges Span adjust from 0 to ±99,999, zero adjust from -99,999 to +99,999

More information

ALLEN BRADLEY TIMING RELAY

ALLEN BRADLEY TIMING RELAY ALLEN BRADLEY TIMING RELAY Configuration Details Product: 700-HS12BA1 Description: 700-HS General Purpose Square Base Timing Relay, On Delay Timer, 1.0 to 180 seconds, DPDT, 120V AC 50/60Hz CONTROL RELAY

More information

FEATURES. Measurement and Verifi cation (M&V) Studies Electrical Load Profi ling Energy Audits New Technology Assessment Studies

FEATURES. Measurement and Verifi cation (M&V) Studies Electrical Load Profi ling Energy Audits New Technology Assessment Studies FEATURES Works on single or 3-phase loads on 0-600V (AC or DC) voltage services. Measures up to four channels of current from 0-6,000 amps (AC current only). Line-powered no need for batteries or external

More information

SAFETY TERMS AND SYMBOLS

SAFETY TERMS AND SYMBOLS Contents Page Safety Terms and Symbols. 1 Introduction. 4 Preliminary Notes 5 Panel Description. 6 Operation Method... 10 Specifications 13 Maintenance. 16 Cleaning 16. Troubleshooting 16. Interchangeable

More information

POWERSCOUT SERIES FEATURES NETWORKED POWER METERS HIGH PERFORMANCE INSTRUMENTS FOR ENERGY MEASUREMENT

POWERSCOUT SERIES FEATURES NETWORKED POWER METERS HIGH PERFORMANCE INSTRUMENTS FOR ENERGY MEASUREMENT SERIES NETWORKED POWER METERS HIGH PERFORMANCE INSTRUMENTS FOR ENERGY MEASUREMENT FEATURES Monitors voltage, current, power, energy, and many other electrical parameters on single and three-phase electrical

More information

HDRFI Series Tensolite High-Performance Cable & Interconnect Systems. High Density RF Interconnect

HDRFI Series Tensolite High-Performance Cable & Interconnect Systems. High Density RF Interconnect HDRFI Series Tensolite High-Performance Cable & Interconnect Systems High Density RF Interconnect HDRFI is a patented Tensolite connection system that transfers high frequency signals through a unique

More information

Magnecraft Power Relays

Magnecraft Power Relays Description DPST-NO, 30 A; DPDT, 30 A (NO) / 3 A (NC) Description The series power relays offer a small package size and features Class F insulation for a maximum coil temperature of 55 C (3 F). These

More information

Type Contact form Model Ag (Au clad) Standard DPDT G6A-274P-ST-US Low-sensitivity DPDT G6A-274P-ST40-US

Type Contact form Model Ag (Au clad) Standard DPDT G6A-274P-ST-US Low-sensitivity DPDT G6A-274P-ST40-US Low Signal Relay G6A Fullly Sealed Relay with High Impulse Withstand High sensitivity can be driven by digital circuits. Low-profile design allows use in 12.70 mm PC board rack. Surge withstand meets FCC

More information

Part-Turn Electric Multi-Turn Electric

Part-Turn Electric Multi-Turn Electric Optional 7 Handwheel Available NEMA 4 Enclosure Approvals MAR s Only (Canadian Standard Association) Enclosure NEMA 7 Enclosure Approvals MAR s Only (Canadian Standard Association) Class I, Divisions 1

More information

Definite Purpose Contactors

Definite Purpose Contactors Definite Purpose Contactors Your order must include: 1) complete cat. no. of selected contactor, and 2) auxiliary contacts, if required. 20/25 FLA 1 and 2 Pole 1-Pole Contactor with Shunt 2-Pole Contactor

More information

45 Hz to 500 Hz 1.0% Hz to 1 khz 2.0% + 3. Accuracy 0.09% + 2. Range / resolution. Range / resolution. Accuracy 1% + 2

45 Hz to 500 Hz 1.0% Hz to 1 khz 2.0% + 3. Accuracy 0.09% + 2. Range / resolution. Range / resolution. Accuracy 1% + 2 AC Voltage Range¹ / resolution 2 3 4 45 Hz to 500 Hz 1.0% + 3 500 Hz to 1 khz 2.0% + 3 600.0 mv / 0.1 mv 6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V 1000 V / 1 V 1. All AC voltage ranges are specified

More information

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories PBC series IEC-Type Contactors & Accessories 9-80 Amp AC-3, 25-125 Amp AC-1 AC Coils File E38802 (PBC) RoHS Ready Users should thoroughly review the technical data before selecting a product part number.

More information

IQ Analyzer 6400/6600 Series. Cutler-Hammer Power Management Products High End Metering Capabilities

IQ Analyzer 6400/6600 Series. Cutler-Hammer Power Management Products High End Metering Capabilities IQ Analyzer 6400/6600 Series Cutler-Hammer Power Management Products High End Metering Capabilities New IQ Analyzer Available May 2000 6400/6600 Series 2 Power Quality Monitoring Over 150 metered parameters

More information

Clamp 200 A AC/DC (+ V AC/DC + Ω)

Clamp 200 A AC/DC (+ V AC/DC + Ω) PCE-DC1 Clamp meter 200 A AC/DC & Freq. LC display 3 2/3 digits, with backlight measures AC / DC current, AC voltage & frequency Hold function / DC A zero reset function tests voltage without contact automatic

More information

ELECTRONIC HARMONICS METER RELAY

ELECTRONIC HARMONICS METER RELAY PRODUCT CATALOG ELECTRONIC HARMONICS METER RELAY OUTLINE * RMS value, fundamental wave RMS value, conversion RMS value/, n-time harmonic RMS value/ / distortion factor can be measured or monitored by 1

More information

80i-500s AC CURRENT PROBE FOR OSCILLOSCOPES

80i-500s AC CURRENT PROBE FOR OSCILLOSCOPES 80i-500s AC CURRENT PROBE FOR OSCILLOSCOPES Instruction Sheet INTRODUCTION The Fluke 80i-500s is a clamp-on current probe that is designed to reproduce current waveforms found in modern commercial and

More information

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40 Characteristics Type of contactor LC- LC- LC- LC- LC-D & D09 D8 D2 D38 D40 D0 D9 LC-D0 DT20 & DT2 DT32 & DT40 Environment Rated insulation voltage (Ui) Conforming to IEC 947-4-, overvoltage category III,

More information

Modular Lube Lubrication Systems System Controls

Modular Lube Lubrication Systems System Controls Model 84501 Program Timer Solid State Designed to control the lubrication cycle frequency of air-operated single-stroke pumps. Timer turns pump on/off at programmed intervals via a 3-way or 4-way air solenoid

More information

Bulletin 190 IEC Modular Starter System

Bulletin 190 IEC Modular Starter System Bulletin 90 Table of Contents Selection Guide Description Page Bulletin 90....................................... Accessories....................................... 7 Specifications.....................................

More information

EVC300i. Generator Automatic Voltage Regulator Operation Manual

EVC300i. Generator Automatic Voltage Regulator Operation Manual EVC300i Generator Automatic Voltage Regulator Operation Manual 1. INTRODUCTION The EVC300i Voltage Regulator is thyristor base to control the DC exciter field power of conventional 50 or 60 Hz brushless

More information

MASTR II BASE STATION 12/24V POWER SUPPLY 19A149979P1-120 VOLT/60 Hz 19A149979P2-230 VOLT/50 Hz

MASTR II BASE STATION 12/24V POWER SUPPLY 19A149979P1-120 VOLT/60 Hz 19A149979P2-230 VOLT/50 Hz Mobile Communications MASTR II BASE STATION 12/24V POWER SUPPLY 19A149979P1-120 VOLT/60 Hz 19A149979P2-230 VOLT/50 Hz CAUTION THESE SERVICING INSTRUCTIONS ARE FOR USE BY QUALI- FIED PERSONNEL ONLY. TO

More information

EVC600i. Generator Automatic Voltage Regulator Operation Manual

EVC600i. Generator Automatic Voltage Regulator Operation Manual EVC600i Generator Automatic Voltage Regulator Operation Manual 1. INTRODUCTION The EVC600i Voltage Regulator is thyristor base to control the DC exciter field power of conventional 50 or 60 Hz brushless

More information

Certificate of Calibration

Certificate of Calibration Certificate of Calibration Manufacturer Radian Research, Inc. Instrument Model: Serial Number 123456 Firmware Revision: 07.10.14 Error Specification.01% worst case Quality Management System Customer Name:

More information

Series CT7N Bimetallic Overload Relays

Series CT7N Bimetallic Overload Relays Series CT7N imetallic Overload Relays Choose CT7N overloads in DC applications and when monitoring Variable Frequency Drives Sprecher + Schuh has always paid particular attention to the subject of motor

More information

OSCILLOSCOPE AND DIGITAL MULTIMETER

OSCILLOSCOPE AND DIGITAL MULTIMETER Exp. No #0 OSCILLOSCOPE AND DIGITAL MULTIMETER Date: OBJECTIVE The purpose of the experiment is to understand the operation of cathode ray oscilloscope (CRO) and to become familiar with its usage. Also

More information

Self Excited Automatic Voltage Regulator For Generator Compatible with Marathon SE350* Operation Manual

Self Excited Automatic Voltage Regulator For Generator Compatible with Marathon SE350* Operation Manual Self Excited Automatic Voltage Regulator For Generator Compatible with Marathon SE350* Operation Manual s * Use for reference purpose only and not a genuine Marathon product. 1. INTRODUCTION Sensing Input

More information

222 HARTREY AVE., EVANSTON, IL U.S.A. AREA CODE 312/ CABLE: SHUREMlCRO. Copyright 1973, Shure Brothers Inc.

222 HARTREY AVE., EVANSTON, IL U.S.A. AREA CODE 312/ CABLE: SHUREMlCRO. Copyright 1973, Shure Brothers Inc. 222 HARTREY AVE., EVANSTON, IL. 60204 U.S.A. AREA CODE 312/328-9000 CABLE: SHUREMlCRO General: The Shure Model M63 Audio Master is a unit designed to give maximum flexibility in the control of volume,

More information

Agilent 5345A Universal Counter, 500 MHz

Agilent 5345A Universal Counter, 500 MHz Agilent 5345A Universal Counter, 500 MHz Data Sheet Product Specifications Input Specifications (pulse and CW mode) 5356C Frequency Range 1.5-40 GHz Sensitivity (0-50 deg. C): 0.4-1.5 GHz -- 1.5-12.4 GHz

More information

Type MG-6 Auxiliary Relay Class 1E

Type MG-6 Auxiliary Relay Class 1E Type MG-6 Auxiliary Relay Class 1E Product Guide Device Number: 94X, Y, Z ZPA Rating 4.2g ABB Application MG-6 relays have been specially designed and tested to establish their suitability for Class 1E

More information

FEATURES. Measurement and Verification (M&V) Studies Electrical Load Profiling Energy Audits New Technology Assessment Studies

FEATURES. Measurement and Verification (M&V) Studies Electrical Load Profiling Energy Audits New Technology Assessment Studies FEATURES For single or 3-phase systems using 80-600V phase-to-phase (AC or DC) services when line powered or 0-600V (AC or DC) when externally powered. Measures up to four channels of energy metrics with

More information

DATA SHEET. Synchronisers, FAS-113DG ANSI code 25

DATA SHEET. Synchronisers, FAS-113DG ANSI code 25 DATA SHEET Synchronisers, ANSI code 25 Synchronisation of generator to busbar Circuit breaker time compensation LED indication of status LED for activated control LED for synchronising signal 35 mm DIN

More information

Digital Delay / Pulse Generator DG535 Digital delay and pulse generator (4-channel)

Digital Delay / Pulse Generator DG535 Digital delay and pulse generator (4-channel) Digital Delay / Pulse Generator Digital delay and pulse generator (4-channel) Digital Delay/Pulse Generator Four independent delay channels Two fully defined pulse channels 5 ps delay resolution 50 ps

More information

EMS DATA ACQUISITION AND MANAGEMENT (LVDAM-EMS) MODEL 9062-C

EMS DATA ACQUISITION AND MANAGEMENT (LVDAM-EMS) MODEL 9062-C A Electric Power / Controls 2 kw EMS DATA ACQUISITION AND MANAGEMENT (LVDAM-EMS) MODEL 9062-C GENERAL DESCRIPTION The Lab-Volt Data Acquisition and Management for Electromechanical Systems (LVDAM-EMS),

More information

E8Y. Micropressure Sensor with Easy-to-Read Digital Display. Differential Pressure Sensor. Ordering Information. Sensors

E8Y. Micropressure Sensor with Easy-to-Read Digital Display. Differential Pressure Sensor. Ordering Information. Sensors Differential Sensor Micropressure Sensor with Easy-to-Read Digital Repeat accuracy of ±1% FS (setting resolution: 0.01 kpa), high-precision pressure control available. Compact design (31 mm) saves mounting

More information

263 Series LED Bargraph Indicator and Controllers

263 Series LED Bargraph Indicator and Controllers 263 Series LED Bargraph Process Control Water Treatment High resolution 51 segment LED Bargraph for easy reading Accuracy 1% Red display Vertical or Horizontal mounting & stackable Connection Diagrams

More information

02/11/2015

02/11/2015 DIN Rail Mount 17.5 mm MUS/MUSF 80 AC/DC Part number 84872141 Control relays monitoring their own power supply - MUS : Over/undervoltage control Selectable latching (memory) function - MUSF : Over/undervoltage

More information

DPS-250AB-18 E. 電氣規格 (Electrical Specification) REV. Description Date DESCRIPTION : MODEL NO. : Date Drawn Desing(EE) Design(ME) DOCUMENT NO. : REV.

DPS-250AB-18 E. 電氣規格 (Electrical Specification) REV. Description Date DESCRIPTION : MODEL NO. : Date Drawn Desing(EE) Design(ME) DOCUMENT NO. : REV. Description Date 07/18/ 08 敖孌鳳孫占蠃杜連軍 ES-250AB-18 E S1 File Name DF-PSLA4V-2R00.DOC SHEET 1 OF 6 1. Input characteristics: 1.1 Input voltage range: 90Vac to 135Vac; 180Vac to 265Vac,single phase. switch

More information

Signal Conditioners. Highlights. Battery powered. Line powered. Multi-purpose. Modular-style. Multi-channel. Charge & impedance converters

Signal Conditioners. Highlights. Battery powered. Line powered. Multi-purpose. Modular-style. Multi-channel. Charge & impedance converters Signal Conditioners Highlights Battery powered Line powered Multi-purpose Modular-style Multi-channel Charge & impedance converters Industrial charge amplifiers & sensor simulators PCB Piezotronics, Inc.

More information

Figure 1: Standard 906 Sensor and Pulser Disc. Figure 2: Standard 906 Sensor and Pulser Wrap

Figure 1: Standard 906 Sensor and Pulser Disc. Figure 2: Standard 906 Sensor and Pulser Wrap Description: The TR5000 is a Full Logic Control Process ratemeter that can display up to three separate values of rate and compare them to programmable set points. Rates A & B can be programmed by the

More information

Universal Hybrid Analog-Digital Voltage Regulator Operation Manual

Universal Hybrid Analog-Digital Voltage Regulator Operation Manual Universal Hybrid Analog-Digital Voltage egulator Operation Manual elf Excited Analog/Digital 5Amp AV For use in shunt and generators with auxiliary windings Warning! 1. Only qualified technicians should

More information

Advanced Test Equipment Rentals ATEC (2832)

Advanced Test Equipment Rentals ATEC (2832) Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) This product is no longer carried in our catalog. AFG 2020 Characteristics Features Ordering Information Characteristics

More information

APQ Series Type C Power Factor Correction Banks

APQ Series Type C Power Factor Correction Banks APQ Series Type C Power Factor Correction Banks N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI 53051 P. (262) 754-3883 F. (262) 754-3993 www.apqpower.com Regardless of the load size or type, APQ will work

More information

HOBO H Energy Logger

HOBO H Energy Logger HOBO H22-001 Energy Logger Logs AC Current Temperature Relative Humidity DC Voltage 4-20 ma AC Voltage Carbon Dioxide DC Current Kilowatt Hours Killowatts The HOBO Energy Logger is a modular, reconfigurable

More information

ProcessMeter. Product Overview

ProcessMeter. Product Overview 787 ProcessMeter Product Overview November 2000 Rev. 1, 12/01 2000, 2001 Fluke Corporation. All rights reserved. Printed in U.S.A. All product names are trademarks of their respective companies. Quick

More information

DATA SHEET Panorama Rudder Indicator, TRI-2

DATA SHEET Panorama Rudder Indicator, TRI-2 DATA SHEET Panorama Rudder Indicator, TRI-2 Class 1 accuracy on CAN version Readable from up to 5 metres Single and dual CAN or analogue interface LED illumination DEIF A/S Frisenborgvej 33 DK-7800 Skive

More information

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A and 3DPT, 10 A UL Listed when used with proper Magnecraft s The 750R series octal base, plug-in relays offer clear or full-feature covers with multiple mounting options and accessories. 750R 750R Full-Feature

More information

DC Motors & Controls. DC2 DC Drives for 1/4 thru 2 Hp PMDC and Shunt Wound Motors. 1/4-2 Hp 115/230 VAC 1 Phase 50/60 Hz.

DC Motors & Controls. DC2 DC Drives for 1/4 thru 2 Hp PMDC and Shunt Wound Motors. 1/4-2 Hp 115/230 VAC 1 Phase 50/60 Hz. HVAC Farm Duty Brake 200 & 575 Volt & Controls DC 310 DC2 DC Drives for 1/4 thru 2 Hp PMDC and Shunt Wound DC & Controls 1/4-2 Hp 115/ 1 Phase 50/60 Hz. Applications: General purpose industrial use with

More information

EA350. Generator Automatic Voltage Regulator Operation Manual

EA350. Generator Automatic Voltage Regulator Operation Manual Generator Automatic Voltage Regulator Operation Manual Self Excited Automatic Voltage Regulator For General Generators Compatible with Marathon SE350* * Use for reference purpose only and not a genuine

More information

www. ElectricalPartManuals. com l Basler Electric VOLTAGE REGULATOR FEATURES: CLASS 300 EQUIPMENT AVC63 4 FEATURES AND APPLICATIONS

www. ElectricalPartManuals. com l Basler Electric VOLTAGE REGULATOR FEATURES: CLASS 300 EQUIPMENT AVC63 4 FEATURES AND APPLICATIONS Using enhanced technology, the AVC63-4 voltage regulator is designed for use on 50/60 Hz brushless generators. This encapsulated regulator is economical, small in size, ruggedly constructed, and incorporates

More information

User Manual Power and Harmonics Analyzer Model PQ3350

User Manual Power and Harmonics Analyzer Model PQ3350 User Manual Power and Harmonics Analyzer Model PQ3350 Additional User Manual Translations available at www.extech.com EN 61010-2-032 CAT III 600V Pollution Degree 2 Definition of Symbols: Caution: Refer

More information

Selection guide siemens.com/sirius-modular-system

Selection guide siemens.com/sirius-modular-system SIRIUS modular system Selection guide siemens.com/sirius-modular-system Everything for the control cabinet: SIRIUS modular system Efficiently combined Advantages at a glance: Load feeders: easy to implement

More information

14 GHz, 2.2 kw KLYSTRON GENERATOR GKP 22KP 14GHz WR62 3x400V

14 GHz, 2.2 kw KLYSTRON GENERATOR GKP 22KP 14GHz WR62 3x400V 14 GHz, 2.2 kw KLYSTRON GENERATOR GKP 22KP 14GHz WR62 3x400V With its characteristics of power stability independent of the load, very fast response time when pulsed (via external modulated signal), low

More information

Part No. ENC-LAB01 Users Manual Introduction EncoderLAB

Part No. ENC-LAB01 Users Manual Introduction EncoderLAB PCA Incremental Encoder Laboratory For Testing and Simulating Incremental Encoder signals Part No. ENC-LAB01 Users Manual The Encoder Laboratory combines into the one housing and updates two separate encoder

More information

HIGH VOLTAGE SWITCH PERFORMANCE OF THE EIMAC X-2159 TETRODE ABSTRACT

HIGH VOLTAGE SWITCH PERFORMANCE OF THE EIMAC X-2159 TETRODE ABSTRACT HIGH VOLTAGE SWITCH PERFORMANCE OF THE EIMAC X-2159 TETRODE by Bobby R. Gray High Power Component & Effects Section Techniques Branch Surveillance Division Rome Air Development Center Griffiss Air Force

More information

WVR500 Waveform/Vector Monitor

WVR500 Waveform/Vector Monitor Service Manual WVR500 Waveform/Vector Monitor 070-8897-01 Warning The servicing instructions are for use by qualified personnel only. To avoid personal injury, do not perform any servicing unless you are

More information

OPERATING INSTRUCTIONS FOR SYLVANIA. Type I08 Cathode-Ray Oscilloscope. Sylvania Electric Products Inc. Industrial Apparatus. Emporium, Pennsylvania

OPERATING INSTRUCTIONS FOR SYLVANIA. Type I08 Cathode-Ray Oscilloscope. Sylvania Electric Products Inc. Industrial Apparatus. Emporium, Pennsylvania OPERATING INSTRUCTIONS FOR SYLVANIA Type I08 Cathode-Ray Oscilloscope Sylvania Electric Products Inc. Industrial Apparatus Plant Emporium, Pennsylvania OPERATING INSTRUCTIONS FOR Sylvania Type 08 Cathode-Ray

More information

LOW-COST, 3 1/2 DIGIT DC VOLTMETERS MODEL 201A & 201AN OPTION 201AN-AC / 301AN

LOW-COST, 3 1/2 DIGIT DC VOLTMETERS MODEL 201A & 201AN OPTION 201AN-AC / 301AN LOW-COST, 3 1/2 DIGIT DC VOLTMETERS MODEL 201A & 201AN OPTION 201AN-AC / 301AN STANDARD FEATURES ±1,999-count display span ±200 mv to ±200 Vdc ranges True-differential input with 80 db CMR 3-wire ratio

More information

Linear flow control with actuator IFC

Linear flow control with actuator IFC Linear flow control with actuator Product brochure GB 3 Edition 01.14 Linear relationship between adjustment angle and flow rate Large control ratio of 25:1 EC type-tested and certified Actuators IC 20

More information

3M Sensored Termination (15 kv) QX-T15I-vi1-E

3M Sensored Termination (15 kv) QX-T15I-vi1-E 3M Sensored Termination () QX-T15I-vi1-E Data Sheet May 2016 Kit Contents: Each kit contains sufficient quantities of the following materials to make three single-phase terminations. 31" (REF) One piece

More information

EA63-7D. Generator Automatic Voltage Regulator Operation Manual. Self Excited Automatic Voltage Regulator

EA63-7D. Generator Automatic Voltage Regulator Operation Manual. Self Excited Automatic Voltage Regulator EA63-7D Generator Automatic Voltage Regulator Operation Manual Self Excited Automatic Voltage Regulator SP POWERWORLD LTD Willows, Waterside, Ryhall, Stamford, Lincs, PE9 4EY, UK Tel: +44 1780 756872 -

More information

CP-830FP Chassis TX-29E50D TX-29E50D/B TX-29PS12D TX-29PS12F TX-29PS12P SPECIFICATIONS. Order No: PCZ C2

CP-830FP Chassis TX-29E50D TX-29E50D/B TX-29PS12D TX-29PS12F TX-29PS12P SPECIFICATIONS. Order No: PCZ C2 Order No: PCZ0510103C2 SPECIFICATIONS Power Source: Power Consumption: 220-240V a.c.,50hz 100W Stand-by Power Consumption: 1,5W Aerial Impedance: 75Ω unbalanced, Coaxial Type Receiving System: PAL-I, B/G,

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker

Magnetic and Hydraulic-Magnetic Circuit Breaker Magnetic and Hydraulic-Magnetic Circuit Breaker 850-... Description Single, two, three and four pole magnetic and hydraulic-magnetic circuit breakers with trip-free-mechanism and toggle or rocker actuation.

More information

Level Measurement silometer FMC 420, FMC 423

Level Measurement silometer FMC 420, FMC 423 Technical Information TI 077F/00/en Level Measurement silometer FMC 420, FMC 423 For connecting to capacitance probes or Deltapilot S hydrostatic probes Main applications The is used for continuous level

More information

SITOP power supply. Technical data, April SITOP Power Supply. Answers for industry.

SITOP power supply. Technical data, April SITOP Power Supply. Answers for industry. SITOP power supply Technical data, April 2010 SITOP Power Supply Answers for industry. SITOP reliable power supply Efficient operation of a machine or plant requires a reliable, constant power supply.

More information

TELEDYNE HASTINGS INSTRUMENTS

TELEDYNE HASTINGS INSTRUMENTS DVT (Digital VT) DCVT (Digital CVT) www.teledyne-hi.com TELEDYNE HASTINGS INSTRUMENTS Vacuum Measurement RANGES DV-4 (0.1 20 Torr) DV-5 (0.1 100 mtorr) DV-6 (1 999 mtorr) FEATURES Linear Analog Output

More information

MAP110 AC-DC Series Data Sheet

MAP110 AC-DC Series Data Sheet Description Single-Output Model Selection VOLTAGE RANGE OUTPUT CURRENT OUTPUT CURRENT REGULATION REGULATION %p-p (NOTE 1) ACCURACY MAP110-1005 5V 4.95V to 5.50 16A 2 0.2% 1% 1% 5.09V to 5.11V MAP110-1012

More information

BE1-81O/U Frequency Protection. Washington State University Hands-On Relay School.

BE1-81O/U Frequency Protection. Washington State University Hands-On Relay School. Frequency Protection Washington State University Hands-On Relay School www.basler.com Relay Benefits As many as four independent, adjustable frequency setpoints and time delays Each setpoint has output

More information

LX3V-4AD User manual Website: Technical Support: Skype: Phone: QQ Group: Technical forum:

LX3V-4AD User manual Website: Technical Support: Skype: Phone: QQ Group: Technical forum: User manual Website: http://www.we-con.com.cn/en Technical Support: support@we-con.com.cn Skype: fcwkkj Phone: 86-591-87868869 QQ Group: 465230233 Technical forum: http://wecon.freeforums.net/ 1. Introduction

More information

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features: HM 1808 LVDT Inductive Position Transducer - Hydraulic Series SM-HYD Hydraulic Series Key-Features: Content: - Screw flange M18x1,5 / M30x1,5 or plug-in flange Ø18 - Pressure up to 400 bar - Measurement

More information

Certificate of Calibration

Certificate of Calibration Certificate of Calibration We hereby certify that this product has been calibrated and found to be in accordance with the applicable SPECIFICATIONS and STANDARDS. Accuracies of the standard equipment used

More information

Bulletin 509 Full Voltage

Bulletin 509 Full Voltage Bulletin 509 Full Voltage Example Cat. No. 509 B O D A2E 17 a b c d e f a Bulletin No. Bulletin No. 509 Top-wired starter 509DC Top-wired starter (DC voltage) b NEMA Size T 00 A 0 B 1 C 2 D 3 E 4 F 5 G

More information

4830A Accelerometer simulator Instruction manual. IM4830A, Revision E1

4830A Accelerometer simulator Instruction manual. IM4830A, Revision E1 4830A Accelerometer simulator Instruction manual IM4830A, Revision E1 IM4830, Page 2 The ENDEVCO Model 4830A is a battery operated instrument that is used to electronically simulate a variety of outputs

More information

18 GHz, 2.2 kw KLYSTRON GENERATOR GKP 24KP 18GHz WR62 3x400V

18 GHz, 2.2 kw KLYSTRON GENERATOR GKP 24KP 18GHz WR62 3x400V 18 GHz, 2.2 kw KLYSTRON GENERATOR GKP 24KP 18GHz WR62 3x400V With its characteristics of power stability whatever the load, very fast response time when pulsed (via external modulated signal), low ripple,

More information

POWER SUPPLIES COAX DC INSERTERS SITUATION

POWER SUPPLIES COAX DC INSERTERS SITUATION SITUATION devices require voltage on the coax output connector and RF signals must pass from input to output on the power inserter. SOLUTION Sonora power inserters couple regulated voltage on coax cables

More information