User s and operator s manual for art

Size: px
Start display at page:

Download "User s and operator s manual for art"

Transcription

1 User s and operator s manual for art

2 Safety informations... page 1 Warnings... page 2 Technical features... page 3 Lamp installation, replacement and setting... page 4 Connection to the mains power... page 5 Connection to the data link (DMX)... page 6 ENGLISH INDEX Control panel... page 7 Summary of the programming functions... page 8 Automode functioning... page 10 DMX values and games table... page 11 (r3_11/2011) 1

3 WARNING SAFETY INFORMATION READ ALL CAUTIONS AND WARNINGS PRIOR TO OPERATE THIS EQUIPMENT. INSTRUCTION TO PREVENT INJURY OR DAMAGE DUE TO ELECTRIC SHOCK, FIRE, MECHANICAL HAZARDS AND UV RADIATION HAZARDS. PROTECTION AGAINTS FIRE 1) This equipment is designed for use with the following lamps only: MSD 575HR, MSR 575HR. Other available lamps: HMP 575SE, BA 800SE, MSA 600SE. DO NOT USE ANY OTHER TYPE LAMP! 2) Maintain minimum distance of 0.5 meter from walls or any other type flammable surfaces. 3) Maintain minimum distance to lighted objects of 5.0 meter. 4) Replace fuses only with the specified type and rating. 5) Do not install the spot close to heat sources. Do not lay the connection cable on the spot when it is warm. PROTECTION AGAINST ELECTRIC SHOCK 1) This equipment must be earthed. 2) Class I equipment. The power supply cord includes a protective earthing conductor as part of the cord. 3) For connection to the supply mains proceed as pict.1 page 3. The equipment must be connected to branch circuit having a circuit- breacker In=16A Id=0.03A (230VAC) 4) Disconnect power before lamp s replacement or servicing (service personnel). PROTECTION AGAINST MECHANICAL HAZARDS 1) Use secondary safety chain when fixing this equipment. 2) Hot lamp explosion hazard. Do not open the equipment for 300 seconds after switching off. 3) Equipment surface may reach temperature up to 100 C. Allow about five minutes before handling. 4) Replace the lamp if it is damaged or thermally deformed. PROTECTION AGAINST UV RADIATION HAZARDS 1) Do not start on this equipment without lamp enclosure or if the protection screens, or ultraviolets screens are damaged. 2) The protection screens, the lenses, or the ultraviolet filters must be replaced if they are visibly damaged and their effectiveness has been reduced, for example, by cracks or deep scratches. 3) Do not look directly at the lamp while lamp is on. INTRODUCTION Thank you for choosing the Hercules800m! The Hercules800m projects, thanks to an extremely efficient optic system (PATENT PENDING), a powerful light beam which can create numberless color shades. Its performances, in terms of luminousity and lighted surfaces, can reach incredible levels. The Hercules800m comes in unique version: Art HERCULES 800m The Hercules800m can work in automatic mode or in synchro mode, otherwise may be controlled by 8 bit DMX controllers The input protocol is the DMX 512. To drive the Hercules800m we suggest to use either our controller Control Show 512, Control Five or the Easy Control. To make the most of its possibilites and for a correct functioning of this unit in the years to come, we suggest you to read carefully this manual before connecting or putting the spot into use. By doing so you will gain experience with its commands and connections and you will be easily able to use it. 2

4 YOUR REFERENCE Always remember to give the serial number and to specify the model any time you address the seller for information or assistance. BASIC KIT The basic kit of the Hercules800m flood projector consist of: Projector User s manual Power connector DMX connectors (in-out) Studio Due warranty Available on request: Lamp WARNING Check that the fixture has not been damaged during transport. If it has been damaged or it does not work, address the seller. Whether the fixture has been shipped to you directly, please contact the shipping company. Only the consignee (person or company) can claim for these damages. TECHNICAL FEATURES LAMPS Lamps MSD 575 HR MSR 575 HR Available lamps Colour temperature K K HMP 575 SE Lamp life hours hours BA 800 SE Luminous flux lm lm MSA 600 SE Colour rendering index (Ra) > 90 (Ra) > 95 Burning position universal universal OPTIC COLOUR SYSTEM Full CYM unlimited variety of colours and shades. High resolution stepper motors. Shutter. BEAM ANGLE: wxh 40 x45 or 45 x40 New concept optical system with rotating parabole to illuminate the surface with maximum horizontal or vertical beam opening. Motorised variation of the beam opening. CONTROL INPUT Standard interface: RS-485; opto-couplet input Protocol: USITT DMX 512 SETUP AND CONFIGURATION On the control panel with leds menu and buttons AUTOMODE Stand-alone control: auto mode function master/slave (synchro mode) 27 programs DMX CHANNELS 1=motor speed 2=cyan 3=yellow 4=magenta 5=dimmer 6=beam angle 7=remote reset/lamp off POWER SUPPLY Rated voltage: 230v; 50hz (other version upon request) Rated power: 800va Rated current: 4,0a (230v) FUSES (inside of base) Lamp fuse: 2x 5.0a/250v (delay time) Electronic fuse: 2.0a/250v (delay time) POWER FACTOR CORRECTOR: built-in cos ø0.9 DIMENSIONS (wxdxh): mm 675x600x720 (830max) WEIGHT: kgs. 70,0 3

5 LAMP'S INSTALLATION OR REPLACEMENT WARNING IN CASE OF LAMP'S REPLACEMENT OR MAINTENANCE: Do not open the fixture unless 10 minutes have passed from the switching off. Disconnect the fixture from the mains supply. A G C C pict.1 B pict.2 Read all cautions and warnings to page 2 prior to install this equipment. Particularly, read the follow: 1) Disconnect power before lamp s replacement or servicing (service personnel) 2) Do not open the lamp cover (G) for 10 minutes after switching off 3) Wear gloves and goggles to re-lamping or to work inside the unit (service personnel). 4) Loosen the two screws (B), unscrews completely the two screws (A) and open the lamp cover (G), pict.1 5) Unscrews the two screws (C) on the lamp support plate, pict.2 6) Remove the lamp holder (D) and insert the lamp into the lampholder, pict.3 Do not touch the quarz bulb with fingers. If this happenes, clean the bulb before use with dry cloth and alcohol. 7) Replace, with care, the lampholder (D) and screws the two screws (C). 8) Close the lamp cover and screw the four screws (B and A). pict.3 D 4

6 BEAM ANGLE SETTING (default 45 x40 or 40 x45 ) The fixture, thanks to the new concept optical system with rotating parabole (WxD 45 x40 or 40 x45 ), allows to illuminate the surfaces with maximum horizontal or vertical beam opening. Operate as shown in the pictures below to set the vertical or horizontal parabole position (default position is 45 x40 ). The label on the dichroic unit, next page pict.9, shows the correct position of the parabole and the dichroic unit. 1) Unscrews the six screws (S) on the head cover and remove it, pict 5 2) Loosen the two pommels (P) under the dichoic group (I), pict.5a without remove it 3) Rotate (clockwise) of 45 the parabole up to stop it, pict.6 and 6a 4) Screws the two pommels (P), pict.6a 5) Open the four spring lock (S) on the four side of the dichroic group (I), pict.7 6) Lift and rotate the dichroic group (counter-clockwise) and reposition it on the four cylindrical pin (L). 7) Close the four spring lock (S) on the four side of the dichroic group (I), pict.7 8) Put again the head cover once all the operations has been made and screw tightly the six screws (S), pict.5. S M pict.5 P I I S pict.5a P HORIZONTAL BEAM ANGLE 45 X40 (WxH) P L S VERTICAL BEAM ANGLE 40 X45 (WxH) P pict.7 pict.6 P P pict.6a 5

7 To completely remove the dichroic unit (I) operate as shown in the pictures below: 1) Open the spring lock (S) 2) Unscrew the four screws (Q) of the plate (N) 5) Unscrews the screws of the connecter protection (V) and disconnect the connecter (Z) 6) Open the other three spring lock (S) on the three side of the dichroic unit (I) 7) Remove with care the dichroic unit (I) 8) Once all the operations has been made, make sure to reposition with care the dichroic unit on the four cylindrical pin (L), pict. 6a, and reposition all the removed parts. S N Q I IMPORTANT pict.9 pict.8 V Z screw 6

8 CONNECTION TO THE MAINS SUPPLY WARNING The equipment must be earthed. If this rule is not followed, the warranty will be void. CONDUCTOR SIZES (length < 20mt.) MAINS VOLTAGE 230V CROSS SELECTIONAL AREAS 3X1,5 mm 2 (minimum) pict.4 1=N pict.5 INPUT CONNECTOR IP 68 10A - 250V 3 PIN CONNECTOR FOR DMX LINE IN 3 PIN CONNECTOR FOR DMX LINE OUT 2=free pict.4a 3=L Read all cautions and warnings to page 2 prior to install this equipment. Particularly, read the follow: 1) Disconnect power before lamp s replacement or servicing (service personnel). 2) Do not open the lamp cover for 10 minutes after switching off. 3) Wear gloves and goggles to re-lamping or to work inside the unit (service personnel). Before connecting the equipment to the mains power: make sure that the mains voltage and frequency correspond to rated values. The Hercules 800m can be equipped for a mains voltage 230VAC, 50Hz. For a power supply of 100V-120V it is necessary to use one auto transformer with the following features: Output voltage 230V Output current 15A The power supply cords construction is shown in pict.4. For connection to the mains supply proceed as pict. 4a. Pict.5 shows the control panel, the mains power and the DMX connections. The equipment must be connected to branch circuit having a circuit-breacker In=16A Id=0.03A (230VAC) a) Do not install the spot close to the heat sources. b) Observe minimum distance between the fixtures of 1.5 meters. c) Do not lay the connection cable on the spot when it is warm. d) This unit must be positioned as to allow its ventilation. e) The unit must be positioned at least 50cm. from walls or other flammable surfaces. f) Observe minimum distance to lighted objects of 5 meters. External surface temperature Ta 35 C: After 5 minutes work; Tc=75 C. Once the thermic balance has been obtained; Tc=100 C. 4) The protection screens, the lenses, or the ultraviolet filters must be replaced if they are visibly damaged and their effectiveness has been reduced, for example, by cracks or deep scratches. 5) The lamp must be replaced if it has been damaged or thermally deformed. 6) Do not handle the spot by taking it by the head, but always by using the special handles. 7

9 CONNECTION THE DATA LINK (DMX 512) The connection of the DMX signal to the fixture must be made by using the signal input XLR 3 pin connectors which are located on the control panel. The pin nomenclature of the connectors for the connection to the DMX signal is listed in the table. (pict.6) In order to avoid any problem in the signal transmission, it is suggested to use a cable for high speed data transmission (sect. > 2x gnd). If the lines have a total length over mts it is suggested to use a signal amplifier (art DMX repeter amplifier). The usage of a normal microphonic or audio cable is suggested only for lines max 100 mts long. PIN WIRE SIGNAL 1 SHIELD GROUND/RETURN/OV 2 INNER CONDUCTOR DATA COMPLEMENT (-, INVERTED) 3 INNER CONDUCTOR DATA TRUE (+, NON INVERTED) pict.6 DMX TERMINAL LINE WARNING The wrong connection of the terminal line or its non-connection are probably the most frequent reasons for the defective functioning of the DMX line. The terminator is a resistor fitted between the two data lines (shown in pict.7) at the end of the cable furthest from the transmitter. The terminator resistor should have the same value as the impedance of the connection cable. We supply a terminal with a 100 Ohm resistor. It is recommanded that all DMX 512 systems have the termination resistor at the and of the line. TERMINATION RESISTOR pict.7 EXAMPLE 1 Connection controller-spot with 1 DMX 512 output SPOT SPOT SPOT LAST SPOT DMX CONTROLLER OR LIGHT CONSOLE EXAMPLE 2 Connection controller-spot to one DMX 512 output over 150mts long SPOT LAST SPOT TERMINATION RESISTOR DMX CONTROLLER OR LIGHT CONSOLE TERMINATION RESISTOR LINE > 150mts (with microphonic or audio cable) SIGNAL AMPLIFIER 8

10 CONTROL PANEL pict.8 LAMP DIMMER LAMP OFF DMX MENU DOWN UP ENTER pict.8a CONTROL PANEL On the control panel of the Hercules800m (pict.8) you can find, besides the display, the leds and the buttons to use to set the spot. To operate on the control panel, unscrew the nut and remove the plastic protection. Alwais remember to put again the plastic protection when all the operations has been made. LED DMX led flashing: DMX input present off: no DMX input LAMP led flashing: the lamp switching off is remotely controlled off: lamp switched on DIMMER led flashing: off: the lamp is 33% dimmered lamp switched on BUTTONS Four buttons are used to programme the spot: MENU DOWN UP ENTER to select the programming options to go backward in the selected options to go forward in the selected options to confirm the selected options DISPLAY Shows the various menus and the selected options. 9

11 SUMMARY OF THE PROGRAMMING FUNCTIONS Addr nchn FOCU Mode test LHrS FLIP FHrS rset About twenty seconds after the switching on, the number of the software version will be shown on the display in X_00 format. Afterwards the first of the nine available menus will appear: Addr to assign the DMX-512 address Mode DMX512 mode, master with pre-set selection, slave LHrS lamp working hours FHrS fixture total working hours nchn channels number FOCU parabole position test auto-test FLIP display inversion rset reset of the spot To select any of the given options, press the MENU button up to when the required one is shown. Addr (Address) To visualise the DMX address press ENTER. To modify the address press Down and Up buttons and, once the required address has been selected, press and keep ENTER pressed up to when the display stops flashing (it flashes to indicate that the selected option is different from the pre-set one). To go back to the options without making any change, press the MENU button. Mode (Mode) To visualise this mode press ENTER. Use Down and Up buttons to change the mode and, once the required one has been selected, press and keep ENTER pressed up to when the display stops flashing (it flashes to indicate that the selected option is different from the pre-set one). The available options are: no (normal) for the functioning in DMX reception; Pr01 Pr27 (pre-set 01 27) for the master functioning with the respective game, SL (slave) for the functioning as slave. To go back to the options without any change, press the MENU button. LHrS (Lamp Hours) To visualise the number of working hours of lamp press ENTER. The maximum countable number of hours is Exceeding this number, the display will show gr3t (greater than 3 thousands). To reset the counter press simultaneously buttons Down and UP: the display will show CLLH (clear lamp hours). To go back to the options without making any change, press the MENU button. FHrS (Fixture hours) To visualise the number of working hours of fixture press ENTER. The maximum countable number of hours is Exceeding this number, the display will show gr3t (greater than 3 thousands). To reset the counter press simultaneously buttons Down and UP. A control of the memory will be run and all the default settings will be stored: the display will then show Init. If the memory is damaged, the display will show the message FAIL. To go back to the options without making any change, press the MENU button

12 FOCU (Focus control) To visualise the focus position press ENTER. Use Down and Up buttons to change the channel and, once the required one has been selected, press and keep ENTER pressed up to when the display stops flashing (it flashes to indicate that the selected option is different from the pre-set one). It is possible to set 0 to 255 step). To go back to the options without making any change, press the MENU button. nchn (Number of Channel) To visualise the number of channel press ENTER. Use Down and Up buttons to change the channel and, once the required one has been selected, press and keep ENTER pressed up to when the display stops flashing (it flashes to indicate that the selected option is different from the pre-set one). It is possible to set 6 channels or 7 channels ( remote reset and remote lamp switch off ). To go back to the options without making any change, press the MENU button. test (Autotest) To insert the auto-test press ENTER and keep it pressed up to when the display shows the flashing message t-on (test on). To take off the auto-test press the MENU button. To go back to the options without making any change, press the MENU button. FLIP (Display overturning) The display visualisation can be standard or overturned: by pressing the ENTER button the two modes will be alternatively visible. The selected one will be immediately stored in the spot setting. To go back to the options without making any change, press the MENU button. rset (Reset) To run the complete reset press ENTER and keep it pressed up to when the display shows the flashing message r-on (reset on). Once the reset procedure has been completed the spot will go back to the normal setting. To go back to the options without making any change, press the MENU button. DRIVING THE FIXTURE WITH A DMX REMOTE CONTROLLER Select the requested DMX starting address by operating on the Addr option Select the requested number of channel with NChn option Connect the DMX signal between the fixture and the controller Check that the DMX led is flasing. (DMX signal present) If there is no signal, you must manually reset by operating on the RESET option It is possible to choose a standard configuration occupying 6 DMX channels, or a enanched configuration occupying 7 channels. Use the enanched configuration if you want to activate channel 7 which enables the reset of the motors and the switching off of the lamp from the controller. 7 OR 6 CHANNELS (16 bit) MODE SELECTION Press the MENU button on the control panel up to when the option nchn is shown on the display, select it by pressing ENTER and the set indication will appear (6 or 7 channels). If you want to activate channel 7 you must set 6 channels on the display. Pass through the numbers by pressing the buttons UP and DOWN: once you have set the required number, store it by pressing the ENTER button and keep it pressed up to when the display stops flashing (the flashing shows that the selected option is different from the one previously stored). To exit from the selected option without making any change press the MENU button. Here below is shown the list of the functions of the fixture. The complete list of the DMX values can be found to page CHANNELS 6 CHANNELS CH 1= Speed CH 2= Cyan CH 3= Yellow CH 4= Magenta CH 5= Dimmer CH 6= Beam angle CH 7= Reset/Lamp Off CH 1= Speed CH 2= Cyan CH 3= Yellow CH 4= Magenta CH 5= Dimmer CH 6= Beam angle

13 LAMP DIMMER LAMP OFF DMX MENU DOWN UP ENTER pict.9 USE OF THE FIXTURE IN AUTO-MODE A short list of the games can be found to page 11. MASTER Press the MENU button on the control panel up to when the option MODE (pict. 9) is shown on the display, select it by pressing ENTER and the set indication will appear (no...sl). Use Down and Up buttons to change the mode and, once the required one has been selected, press and keep ENTER pressed up to when the display stops flashing (it flashes to indicate that the selected option is different from the pre-set one). The available options are: no (normal) for the functioning in DMX reception; Pr01 Pr27 (pre-set 01 27) for the master functioning with the respective game, SL (slave) for the functioning as slave. To go back to the options without any change, press the MENU button. Mode no use of the fixture in DMX-512 Pr1..Pr27 master functioning with execution of the 27 stored programmes SL use of the fixture in SLAVE MODE EXAMPLE OF CONNECTION AND SETTING OF 4 FIXTURE IN SYNCHRO - MODE WARNING The cables are the same as the DMX standard cable MASTER SLAVE SLAVE SLAVE TERMINATION RESISTOR EXAMPLE OF CONNECTION AND SETTING OF 4 FIXTURE IN INDIPENDENT AUTO - MODE MASTER MASTER MASTER MASTER EXAMPLE TO DRIVE 4 FIXTURES IN DMX 512 (7 CHANNELS ) Spot n 1 Spot n 2 Spot n 3 Spot n 4 Channels 1-7 Channels 8-14 Channels Channels EXAMPLE TO DRIVE 4 FIXTURES IN DMX 512 (6 CHANNELS ) Spot n 1 Spot n 2 Spot n 3 Spot n 4 Channels 1-6 Channels 7-13 Channels Channels

14 DMX VALUES Here is the complete list of DMX values (ref. page 11) GAMES LIST CHANNEL FUNCTION DESCRIPTION DECIMAL PERCENT 1 MOTOR SPEED SPEED MOVEMENT Slow Mid1 Mid2 Fast 2 CYAN CONTINUOUSLY VARIABLE White Full color 3 YELLOW CONTINUOUSLY VARIABLE White Full color 4 MAGENTA CONTINUOUSLY VARIABLE White Full color 5 DIMMER CONTINUOUSLY VARIABLE 0% 100% 6 BEAM ANGLE CONTINUOUSLY VARIABLE 0% 100% 7 REMOTE RESET/ LAMP OFF Normal Reset (delay) Normal Lamp off (delay) PROGRAM FUNCTION 01 Red Magenta Yellow: color mix sequence (slow; 30 sec.) 02 Red Magenta Yellow + White color mix sequence (slow; 30 sec.) 03 Green Cyan Yellow: color mix sequence (slow; 30 sec.) 04 Green Cyan Yellow + White color mix sequence (slow; 30 sec.) 05 Blue Cyan Magenta: color mix sequence (slow; 30 sec.) 06 Blue Cyan Magenta + White color mix sequence (slow; 30 sec.) 07 All colors: color mix sequence (slow; 30 sec.) 08 All colors + White color mix sequence (slow; 30 sec.) 09 All colors: color mix sequence (mid; 20 sec.) 10 All colors + White color mix sequence (mid; 20 sec.) 11 All colors: color mix sequence (mid+; 15 sec.) 12 All colors: color mix sequence (mid+; 15 sec.) 13 All colors + White color mix sequence (fast; 10 sec.) 14 Basic color (6 sec.) 15 Basic color + White (6 sec.) 16 Wood (static) 17 Magenta (static) 18 Red (static) 19 Light Red (static) 20 Orange (static) 21 Yellow (static) 22 Cyan (static) 23 Light Cyan (static) 24 Green (static) 25 Light Green (static) 26 White (static) 27 Ten colors + White (slow; 60 sec.) %..24% 25%..50% 51%..74% 75%..100% 0% 100% 0% 100% 0% 100% 0% 100% 0% 100% 0%..50% 50%..75% 75%..98% 98%..100%

15 NOTE 14

16 Head Office: STUDIO DUE s.r.l. (I) Str. Poggino, Viterbo (Italy) tel fax STUDIO DUE (UK) 3 Encon Court Owl Close Moulton Park Industrial Estate Northampton England UK - NN3 6 HZ tel info@studiodue.co.uk STUDIO DUE Far East LTD (HK) Unit 8, 4/F, Harbour Centre Tower II, 8 Hok Cheung Street, Hunghom, Kowloon Hong Kong. tel fax info@studiodue.com.hk STUDIO DUE lighting technology (PRC) Shen Zhen LTD (China) for technical info service@studiodue.com Studio Due - The features on this brochure are not binding: they can be changed without notice. Le caratteristiche riportate su questo catalogo non sono impegnative: possono essere soggette a variazioni senza preavviso.

Sirio 150 / 150DV. Code 02E010 - Sirio 150 Code 02E011 - Sirio 150DV OPERATING INSTRUCTIONS. COEF srl. Revision 1

Sirio 150 / 150DV. Code 02E010 - Sirio 150 Code 02E011 - Sirio 150DV OPERATING INSTRUCTIONS. COEF srl. Revision 1 COEF srl. Via Albinatico, 80-82 51019 Ponte Buggianese (PT) ITALY www.coef.it / www.coef.net info@coef.it Graphic by PC CAD & VIDEO Sirio 150 / 150DV Code 02E010 - Sirio 150 Code 02E011 - Sirio 150DV OPERATING

More information

User s and operator s manual for art Manuale d uso e dell operatore per art. 0302

User s and operator s manual for art Manuale d uso e dell operatore per art. 0302 User s and operator s manual for art. 0302 Manuale d uso e dell operatore per art. 0302 This page is intentionally left blank Safety informations... page 2 Technical features... page 3 Photometric parameters...

More information

Stratos Duo RGB. User Manual. Order code: EQLED371

Stratos Duo RGB. User Manual. Order code: EQLED371 Stratos Duo RGB User Manual Order code: EQLED1 Safety advice WARNING FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START-UP! Before your initial start-up, please make

More information

Fixture One XLR Signal Cable One Omega Clamp - Two Safety Chain One User Manual - One

Fixture One XLR Signal Cable One Omega Clamp - Two Safety Chain One User Manual - One TABLE OF CONTENTS 1. INTRODUCTION AND UNPACKING 1 2. SAFTEY INSTRUCTIONS 1-2 3. OPERATION INSTRUCTIONS 2-3 4. MOUNTING AND INSTALLATION 3-4 5. DMX-512 CONTROL CONNECTIONS 4-5 6. MENU NAVIGATION 5 7. PHOTOMETRIC

More information

LED Thunder S-150 Code 1097

LED Thunder S-150 Code 1097 LED Thunder S-150 Code 1097 User Manual 1 1 SAFETY INSTRUCTIONS This device has left the factory in perfect condition. In order to maintain this condition and to ensure a safe operation, it is absolutely

More information

SquareLED - Aura Bar & Matrix Beam Light 100

SquareLED - Aura Bar & Matrix Beam Light 100 SquareLED - Aura Bar & Matrix Beam Light 100 1. SAFETY INSTRUCTIONS Please read these instructions carefully they include the important information about the installation usage and maintenance of this

More information

Dragonfly Quad. User Manual V1.4. Order code: EQLED101

Dragonfly Quad. User Manual V1.4. Order code: EQLED101 Dragonfly Quad User Manual V1.4 Order code: EQLED101 Safety advice WARNING FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START-UP! Before your initial start-up, please

More information

Spectra Batten (Order code: LEDJ95)

Spectra Batten (Order code: LEDJ95) www.prolight.co.uk Spectra Batten (Order code: LEDJ95) Safety WARNING FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START-UP! CAUTION! Keep this equipment away from rain,

More information

Fusion 120 Zoom. User Manual. Order code: EQLED068

Fusion 120 Zoom. User Manual. Order code: EQLED068 Fusion 120 Zoom User Manual Order code: EQLED068 Safety advice WARNING FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START-UP! Before your initial start-up, please make

More information

Spectra Flood Q40. Exterior Fixture User Manual. Order code: LEDJ Version LEDJ284N - 15 Version

Spectra Flood Q40. Exterior Fixture User Manual. Order code: LEDJ Version LEDJ284N - 15 Version Spectra Flood Q40 Exterior Fixture User Manual Order code: LEDJ284-40 Version LEDJ284N - 15 Version Safety advice WARNING FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL

More information

BEAM MOVING HEAD YODN Lamp. 132W 2R MOVING HEAD Brightness / Stability USER MANUAL. Version 1.0 beta

BEAM MOVING HEAD YODN Lamp. 132W 2R MOVING HEAD Brightness / Stability USER MANUAL. Version 1.0 beta BEAM MOVING HEAD YODN Lamp W R MOVING HEAD Brightness / Stability This product manual contains important information about the safe installation and use of this projector. Please read and follow these

More information

ORDER CODE: EQLED65 USER MANUAL

ORDER CODE: EQLED65 USER MANUAL www.prolight.co.uk ORDER CODE: EQLED65 USER MANUAL Safety WARNING FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START-UP! CAUTION! Keep this equipment away from rain,

More information

PRODUCT SPECIFICATIONS

PRODUCT SPECIFICATIONS FOS Beam 150W 1 PRODUCT SPECIFICATIONS TECHNICAL SPECIFICATION Voltage: 100/240 Volt AC, 50/60 Hz. Power Consumption: 250 Watt. Light Source: 150 Watt LED, 6800K Beam angle: 2 Colors: 11 dichroic color

More information

ORLAND SCAN PR PR LIGHTING LTD. Yingbin Road, Dashi Panyu, Guangzhou, China

ORLAND SCAN PR PR LIGHTING LTD. Yingbin Road, Dashi Panyu, Guangzhou, China ORLAND SCAN PR-1201 This product manual contains important information about the safe installation and use of this projector. Please read and follow these instructions carefully and keep this manual in

More information

SUPER LED F4.7 VW Vari-White INSTRUCTION MANUAL

SUPER LED F4.7 VW Vari-White INSTRUCTION MANUAL SUPER LED F4.7 VW Vari-White 60W Vari-White from 2.750 to 6.900 K - Enhanced CRI > 94 White light, with Adjustable Correlated Colour Temperature INSTRUCTION MANUAL Operated Pole Operated MANUFACTURER REPRESENTATIVE

More information

ALO 030 MKII. 30 Watt DMX LED scanner. User manual

ALO 030 MKII. 30 Watt DMX LED scanner. User manual ALO 030 MKII 30 Watt DMX LED scanner User manual Safety instructions WARNING! Always keep this device away from moisture and rain! Hazardous electrical shocks may occur! WARNING! Only connect this device

More information

KingWash 7QX 7x40w,Zoom 5-60degree. User manual. Please read the instructions carefully before use TABLE OF CONTENTS

KingWash 7QX 7x40w,Zoom 5-60degree. User manual. Please read the instructions carefully before use TABLE OF CONTENTS KingWash 7QX 7x40w,Zoom 5-60degree User manual Please read the instructions carefully before use TABLE OF CONTENTS 1. Safety Instructions... 2 2. Technical Specifications... 4 3. How To Control The Unit...

More information

LED Beam Moving Head. TWIST-150LED Order No INSTRUCTION MANUAL

LED Beam Moving Head. TWIST-150LED Order No INSTRUCTION MANUAL LED Beam Moving Head TWIST-150LED Order No. 38.7970 INSTRUCTION MANUAL MONACOR INTERNATIONAL GmbH & Co. KG Zum Falsch 36 28307 Bremen Germany www.monacor.com 01.30.11.2016 ELECTRONICS FOR SPECIALISTS ELECTRONICS

More information

LED-BANK4 USER MANUAL. COLORbank 4

LED-BANK4 USER MANUAL. COLORbank 4 LED-BANK4 COLORbank 4 USER MANUAL CHAUVET, 3000 N 29 th Ct, Hollywood, FL 33020 U.S.A (800) 762-084 (954) 929-5 FAX (954) 929-5560 www.chauvetlighting.com 2006-04-8/6:44 Table of Content BEFORE YOU BEGIN...

More information

www. eklights.com Guangzhou Liangyi Lighting Equipments Co.,Ltd. 37 Gongyedadao, Xinhua, Huadu, Guangzhou PC:510800

www. eklights.com Guangzhou Liangyi Lighting Equipments Co.,Ltd. 37 Gongyedadao, Xinhua, Huadu, Guangzhou PC:510800 Guangzhou Liangyi Lighting Equipments Co.,Ltd. 37 Gongyedadao, Xinhua, Huadu, Guangzhou PC:510800 Tel: (020)666 090 88-8002 Fax: (020) 868 670 11 www. eklights.com USER MANUAL CONTENTS SAFETY DIMENSION

More information

User Manual. 360W LED Moving Zoom KEEP THIS MANUAL FOR FUTURE NEEDS. 36pcs10W 4 in 1 RGBW LEDs

User Manual. 360W LED Moving Zoom KEEP THIS MANUAL FOR FUTURE NEEDS. 36pcs10W 4 in 1 RGBW LEDs User Manual 360W LED Moving Zoom 36pcs10W 4 in 1 RGBW LEDs KEEP THIS MANUAL FOR FUTURE NEEDS 1. Dispacking Thank you for choosing our moving head. For your own safety, please read this manual before installing

More information

LED SPOT HEAD USERS GUIDE

LED SPOT HEAD USERS GUIDE LED SPOT HEAD USERS GUIDE 1 1. Product Introduction: 1.1 Before unpack the fixture, pls make sure that the packing is in good condition, following items will be found in the box: - The fixture - This users

More information

SOFT LED 4 Vari-White INSTRUCTION MANUAL

SOFT LED 4 Vari-White INSTRUCTION MANUAL SOFT LED 4 Vari-White 180W LED SOFTLIGHT 90-250V 50/60 Hz (white light, with tunable correlated color temperature from 2.800 to 6.600 K) INSTRUCTION MANUAL Manual Operated (Pole Operated available, not

More information

Hex-color RGBAW+UV LED strip light

Hex-color RGBAW+UV LED strip light Hex-color RGBAW+UV LED strip light 2 19 SAFETY / GENERAL INSTRUCTIONS INTRODUCTION Features Specifications OVERVIEW : CONNECTIONS Rear view DIMENSIONS INSTALLATION Mounting FUNCTIONS AND SETTINGS Function

More information

ArtFox Lighting. LED Beam Wash 19E. User manual. 6. Fixture Cleaning. Please read the instructions carefully before use

ArtFox Lighting. LED Beam Wash 19E. User manual. 6. Fixture Cleaning. Please read the instructions carefully before use 6. Fixture Cleaning ArtFox Lighting LED Beam Wash 19E The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to optimize light output. Cleaning frequency depends

More information

Page 1 of 6 FXLD618FRP2I4 LED FIXTURE Version 0.2 OWNERS MANUAL 10/04/17

Page 1 of 6 FXLD618FRP2I4 LED FIXTURE Version 0.2 OWNERS MANUAL 10/04/17 Page 1 of 6 FEATURES AND SPECIFICATIONS LEDS: 18, 6W each (Warm White, Cool White, 2in1) Beam angle: 25º or 45 Control system: DMX512 + Stand Alone Modes DMX channels: 1/2/3/4/5 DMX connectors: 3 pin XLR

More information

aorun manual V2.0 MARCH 2018

aorun manual   V2.0 MARCH 2018 aorun manual V2.0 MARCH 2018 table of CONTENTS Dimensions 2 Safety instruction 5 Physical installation 6 Control panel 8 Menu navigation 9 DMX Protocols 12 DMX protocol CH14 12 DMX protocol CH16 15 DMX

More information

This device is a lighting effect for professional use on stages, in discotheques, theatres, etc..

This device is a lighting effect for professional use on stages, in discotheques, theatres, etc.. At first, thank you for purchasing QUADRO 24. For the sake of safety and regular operation of this projector, please read this manual carefully before using and operating it, lest incur any personal injury

More information

Mover Beam 7 CKU (US) / CKE (EU) USER MANUAL

Mover Beam 7 CKU (US) / CKE (EU) USER MANUAL Mover Beam 7 CKU01-5030 (US) / CKE01-5030 (EU) USER MANUAL Introduction Thank you for purchasing the ColorKey Mover Beam 7. Please read these instructions carefully before use. Operating this fixture according

More information

LED IP65 Slimline Par RGBWA +UV 7x12W

LED IP65 Slimline Par RGBWA +UV 7x12W VIS0495.4 LED IP65 Slimline Par RGBWA +UV 7x12W User Manual KEEP THIS MANUAL FOR FURTHER NEEDS Key Features: 7 x RGBAW + UV HEX 12W LED IP65 Weatherproof Die-Cast Housing Slimline, Compact & Stylish Design

More information

USER MANUAL. TS-3 DMX-Scanner. For your own safety, please read this user manual carefully before you initial start-up.

USER MANUAL. TS-3 DMX-Scanner. For your own safety, please read this user manual carefully before you initial start-up. USER MANUAL TS- DMX-Scanner For your own safety, please read this user manual carefully before you initial start-up. Every person involved with the installation, operation and maintenance of this device

More information

PRODUCT SPECIFICATIONS

PRODUCT SPECIFICATIONS FOS Spot 150W 1 PRODUCT SPECIFICATIONS TECHNICAL SPECIFICATION Voltage: 100/240 Volt AC, 50/60 Hz. Power Consumption: 250 Watt. Light Source: 150 Watt LEDs, 7500K. Beam angle: 14. Colors: 8 colors + White

More information

LED SPOT HEAD USERS GUIDE

LED SPOT HEAD USERS GUIDE LED SPOT HEAD USERS GUIDE 1. Product Introduction: 1 1.1 Before unpack the fixture, pls make sure that the packing is in good condition, following items will be found in the box: -The fixture -This users

More information

Operating Manual. Automated Gear. Apollo Design Technology, Inc Fourier Drive Fort Wayne, IN USA

Operating Manual. Automated Gear. Apollo Design Technology, Inc Fourier Drive Fort Wayne, IN USA Operating Manual Automated Gear Apollo Design Technology, Inc. 4130 Fourier Drive Fort Wayne, IN 46818 USA PH: +01(260)497-9191 FX: +01(260)497-9192 www.apollodesign.net 11-25-09 5-6 POWERING UP THE RIGHT

More information

ALO 060 DMX LED scanner

ALO 060 DMX LED scanner ALO 060 DMX LED scanner User manual Safety instructions WARNING! Always keep this device away from moisture and rain! Hazardous electrical shocks may occur! WARNING! Only connect this device to a matching

More information

User Manual MAINTENANCE AND CLEANING. CAUTION Disconnect from mains before starting maintenance operation. KEEP THIS MANUAL FOR FUTURE NEEDS

User Manual MAINTENANCE AND CLEANING. CAUTION Disconnect from mains before starting maintenance operation. KEEP THIS MANUAL FOR FUTURE NEEDS 0 MAINTENANCE AND CLEANING The following points have to be considered during the inspection: ) All screws for installing the devices or parts of the device have to be tightly connected and must not be

More information

TRANSCENSION 6-CHANNEL DMX DIMMER PACK (order code: BOTE40) USER MANUAL

TRANSCENSION 6-CHANNEL DMX DIMMER PACK (order code: BOTE40) USER MANUAL www.prolight.co.uk TRANSCENSION 6-CHANNEL PACK (order code: BOTE40) USER MANUAL SAFETY WARNING FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START-UP! CAUTION! Keep this

More information

DESIGN 250 PR PR LIGHTING LTD. No. 571, Yingbin Road, Dashi Panyu, Guangzhou, China

DESIGN 250 PR PR LIGHTING LTD. No. 571, Yingbin Road, Dashi Panyu, Guangzhou, China DESIGN 250 PR-1250 This product manual contains important information about the safe installation and use of this projector. Please read and follow these instructions carefully and keep this manual in

More information

80W SPOT MOVING HEAD CYCLONE-80 USER GUIDE April 2014 version

80W SPOT MOVING HEAD CYCLONE-80 USER GUIDE April 2014 version 80W SPOT MOVING HEAD CYCLONE-80 USER GUIDE 10175-1 April 2014 version 1 - Safety information Important safety information WARNING : This unit contains no user-serviceable parts. Do not open the housing

More information

BEAM MOVING HEAD WITH 100W OSRAM HRI LAMP AND 8-FACET PRISM USER GUIDE

BEAM MOVING HEAD WITH 100W OSRAM HRI LAMP AND 8-FACET PRISM USER GUIDE BEAM MOVING HEAD WITH 100W OSRAM HRI LAMP AND 8-FACET PRISM USER GUIDE 10410 - Version 1 / 11-2015 English Ray1R - Beam moving head with 100W OSRAM HRI LAMP and 8-facet prism 1 - Safety information Important

More information

Commander 384. w w w. p r o l i g h t. c o. u k U S E R M A N U A L

Commander 384. w w w. p r o l i g h t. c o. u k U S E R M A N U A L Commander 384 w w w. p r o l i g h t. c o. u k U S E R M A N U A L 1, Before you begin 1.1: Safety warnings...2 3 1.2: What is included...4 1.3: Unpacking instructions...4 2, Introduction 2.1: Features...4

More information

LED Spere Direct Control 30 ORDERCODE 41125

LED Spere Direct Control 30 ORDERCODE 41125 LED Spere Direct Control 30 ORDERCODE 41125 Congratulations! You have bought a great, innovative product from Showtec. The Showtec LED Sphere Direct Control 30 brings excitement to any venue. Whether you

More information

JunoScan MK-II LED scanner. user manual

JunoScan MK-II LED scanner. user manual JunoScan MK-II LED scanner user manual Musikhaus Thomann e.k. Treppendorf 30 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0 E-mail: info@thomann.de Internet: www.thomann.de 26.10.2012 Table of

More information

KEEP THIS MANUAL FOR FUTURE NEEDS

KEEP THIS MANUAL FOR FUTURE NEEDS USER S MANUAL www.lfxgroup.com MOVING HEAD PRO HEAD 250 KEEP THIS MANUAL FOR FUTURE NEEDS For your own safety, please read this user manual carefully before installing the device. Keep this device away

More information

BROTHER, BROTHER & SONS

BROTHER, BROTHER & SONS AREA SOFT BROTHER, BROTHER & SONS ApS INTRO Brother, Brother & Sons ApS The information in this manual is subject to change without notice. Go to www.brothers-sons.dk for the latest version. Brother, Brother

More information

Stage Wash 7x 10W LED Moving Head (RGBW)

Stage Wash 7x 10W LED Moving Head (RGBW) Stage Wash 7x 10W LED Moving Head (RGBW) P/N 612870 User's Manual CONTENTS SAFETY WARNINGS AND GUIDELINES... 3 INTRODUCTION... 4 FEATURES... 5 CUSTOMER SERVICE... 5 PACKAGE CONTENTS... 6 PRODUCT OVERVIEW...

More information

Truss Light COB LED 30W

Truss Light COB LED 30W User manual Truss Light COB LED 30W User manual Focusing tube Truss Light COB LED 30W 2 / 11 Table of contents 1. Safety instructions... 4 1.1. FOR SAFE AND EFFICIENT OPERATION... 4 2. Technical data...

More information

TABLE OF CONTENTS INTRODUCTION

TABLE OF CONTENTS INTRODUCTION 1 TABLE OF CONTENTS INTRODUCTION... 2 MAIN FEATURES... 3 UNPACKING... 3 SAFETY WARNING... 3 PANEL REVIEW... 4 INSTALLATION AND SETTING... 4 1. MULTI-FIXTURES CONNECTION... 4 2. LAMP BODY INSTALLATION...

More information

LED-PAR200B USER MANUAL. COLORsplash 200B

LED-PAR200B USER MANUAL. COLORsplash 200B LED-PAR00B COLORsplash 00B USER MANUAL CHAUVET, 3000 N 9 th Ct, Hollywood, FL 3300 U.S.A (800) 76-084 (954) 99-5 FAX (954) 99-5560 www.chauvetlighting.com 006-07-06/0:3 TABLE OF CONTENT TABLE OF CONTENT...

More information

PROFESSIONAL MOVING HEAD USER S MANUAL DESIGN WASH 250

PROFESSIONAL MOVING HEAD USER S MANUAL DESIGN WASH 250 PROFESSIONAL MOVING HEAD USER S MANUAL DESIGN WASH 250 KEEP THIS MANUAL FOR FUTURE NEEDS For your own safety, please read this user manual carefully before installing the device. K eep thi s devi ce aw

More information

WaferPar HEX 12 CKU (US) / CKE (EU) USER MANUAL

WaferPar HEX 12 CKU (US) / CKE (EU) USER MANUAL WaferPar HEX 12 CKU01-2140 (US) / CKE01-2140 (EU) USER MANUAL Introduction Thank you for purchasing the ColorKey WaferPar HEX 12. Please read these instructions carefully before use. Operating this fixture

More information

192 Channel DMX Controller

192 Channel DMX Controller DM-X 92 Channel DMX Controller USER MANUAL 54. 9UK Vers ion. D M X 5 2 C O N T R O L L E R S E R I E S Content. Before you begin. What is included.......2 Unpacking instructions....3 Safety instructions...

More information

aorun manual V1.0 OCTOBER 2017

aorun manual  V1.0 OCTOBER 2017 aorun manual V1.0 OCTOBER 2017 table of CONTENTS Dimensions 2 Safety information 5 Specifications 7 Included items 8 Physical installation 9 Control panel 11 Operating instructions 12 Channel function

More information

180w led gobo moving USER MANUAL

180w led gobo moving USER MANUAL 180w led gobo moving USER MANUAL 1. BEFORE YOU BEGIN What is included 1 x Light 1 x Mounting bracket and screws 1 x Power cable 1 x User Manual Unpacking Instructions Congratulations on purchasing ART-TECH

More information

GR0660. Instruction manual

GR0660. Instruction manual GOBOSTORM PLUS MK2 GR0660 Instruction manual INDEX 1.0 Introduction...4 1.1 Safety information...4 1.1.1 Protecting against electric shock...4 1.1.2 Installation...4 1.1.3 Protection against burns and

More information

DJ SCAN 150 XT. Table of contents

DJ SCAN 150 XT. Table of contents DJ SCAN 150 XT Table of contents 1. Safety instructions... 3 2. Operating determinations... 4 3. Description of the device... 5 4. Installation... 6 4.1Fitting/Exchanging the lamp... 6 4.2 Rigging the

More information

HEX16 Strip User Manual

HEX16 Strip User Manual User Manual www.showtech.com.au 1 Table of Contents 1. Safety instructions 3 1.1 Overhead rigging.4 1.2 Power Connection..5 1.3 Cleaning and Maintenance..6 2. Menu Navigation..7 3. DMX Allocation..9 4.

More information

thinpar 38

thinpar 38 thinpar 38 OWNER S MANUAL www.venuelightingeffects.com INTRODUCTION The Venue Thinpar 38 is a DMX intelligent LED Par Can. It is lightweight and compact which makes it a great light for clubs, parties,

More information

SPECIFICATIONS: Model: Supply Voltage: LED: Weight: Size: Fuse: Power Consumption: Working Position: Duty Cycle: DMX Channels:

SPECIFICATIONS: Model: Supply Voltage: LED: Weight: Size: Fuse: Power Consumption: Working Position: Duty Cycle: DMX Channels: STEALTH WASH ZOOM Introduction: The Stealth Wash Zoom is a unique DMX intelligent moving head unit. The Stealth Wash Zoom has 3 operating modes; sound active mode, show mode, or controlled via DMX controller.

More information

1. BEFORE YOU BEGIN INTRODUCTION SETUP... 7

1. BEFORE YOU BEGIN INTRODUCTION SETUP... 7 User Manual TABLE OF CONTENTS 1. BEFORE YOU BEGIN... 3 WHAT IS INCLUDED... 3 UNPACKING INSTRUCTIONS... 3 MANUAL CONVENTIONS... 3 ICONS... 3 SAFETY NOTES... 4 2. INTRODUCTION... 5 PRODUCT OVERVIEW... 6

More information

YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE POWERING OR INSTALLING. SAVE IT FOR FUTURE REFERENCE

YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE POWERING OR INSTALLING. SAVE IT FOR FUTURE REFERENCE MYTHIC USER S MANUAL Thank you for purchasing our moving head MYTHIC. Every suit has been thoroughly tested and shipped in perfect condition. Carefully check the shipping carton for damage that may have

More information

PLL1920M LED LCD Monitor

PLL1920M LED LCD Monitor PLL1920M LED LCD Monitor USER'S GUIDE www.planar.com Content Operation Instructions...1 Safety Precautions...2 First Setup...3 Front View of the Product...4 Rear View of the Product...5 Installation...6

More information

6X3W RGB LEDS PROJECTOR FOR PROFESSIONAL TRUSSES USER GUIDE / Version 1

6X3W RGB LEDS PROJECTOR FOR PROFESSIONAL TRUSSES USER GUIDE / Version 1 6X3W RGB LEDS PROJECTOR FOR PROFESSIONAL TRUSSES USER GUIDE 10364-07-2015 / Version 1 English MINITRUSS-6TCb - 6x3W RGB LEDs projector for professional trusses 2 MINITRUSS-6TCb - 6x3W RGB LEDs projector

More information

WASH MOVING HEAD M7W15RGBW USER MANUAL. For safety, please read this user manual carefully before initial use.

WASH MOVING HEAD M7W15RGBW USER MANUAL. For safety, please read this user manual carefully before initial use. 1 WASH MOVING HEAD M7W15RGBW USER MANUAL For safety, please read this user manual carefully before initial use. Event Lighting reserves the right to revise the manual at any time. Information and specifications

More information

User Instructions. Warning! To prevent or reduce the risk of electrical shock or fire, do not expose this unit to rain or moisture.

User Instructions. Warning! To prevent or reduce the risk of electrical shock or fire, do not expose this unit to rain or moisture. General Information User Instructions Unpacking: Thank you for purchasing the by American DJ. Every has been thoroughly tested and has been shipped in perfect operating condition. Carefully check the shipping

More information

User Instructions. Warning! To prevent or reduce the risk of electrical shock or fire, do

User Instructions. Warning! To prevent or reduce the risk of electrical shock or fire, do 7/07 User Instructions American DJ 4295 Charter Street Los Angeles Ca. 90058 www.americandj.com Introduction Unpacking: Thank you for purchasing the by American DJ. Every has been thoroughly tested and

More information

Mini LED Pin Spot Light Model: PLS00571

Mini LED Pin Spot Light Model: PLS00571 Mini LED Pin Spot Light Model: PLS00571 1 Please read these instructions carefully before use and retain for future reference. IMPORTANT SAFETY INFORMATION When using electrical appliances basic safety

More information

AuraBeam 150 LED. User Manual KEEP THIS MANUAL FOR FUTURE NEEDS

AuraBeam 150 LED. User Manual KEEP THIS MANUAL FOR FUTURE NEEDS AuraBeam 150 LED LED 0.2m ta 40 C tc 150 C User Manual KEEP THIS MANUAL FOR FUTURE NEEDS 1 SAFETY INSTRUCTIONS CAUTION Becareful with your operations.with a dangerous voltage you cansuffer a dangerous

More information

DMX LED light effect with 4 lenses

DMX LED light effect with 4 lenses DMX LED light effect with 4 lenses User manual 1 Safety precautions WARNING: This unit may cause serious injury to the eyes when used incorrectly. It is therefore strongly advised to read this user manual

More information

USER MANUAL Table of Contents

USER MANUAL Table of Contents USER MANUA Table of Contents Safety Information.. 3 Specifications.. 4 Main Power Connection.. 5 DMX-512 Connection... 5 Main Control Menu... 6 DMX Profile... 8 Rigging the Fixture....10 Cleaning & Maintenance...10

More information

PILOT 250 PR PR LIGHTING LTD. Yingbin Road, Dashi Panyu, Guangzhou, China

PILOT 250 PR PR LIGHTING LTD. Yingbin Road, Dashi Panyu, Guangzhou, China PILOT 250 PR-2250 This product manual contains important information about the safe installation and use of this projector. Please read and follow these instructions carefully and keep this manual in a

More information

User Instructions. Warning! To prevent or reduce the risk of electrical shock or fire, do not expose this unit to rain or moisture.

User Instructions. Warning! To prevent or reduce the risk of electrical shock or fire, do not expose this unit to rain or moisture. General Information User Instructions Unpacking: Thank you for purchasing the by American DJ. Every has been thoroughly tested and has been shipped in perfect operating condition. Carefully check the shipping

More information

USER MANUAL (SSDL-3201RGB)

USER MANUAL (SSDL-3201RGB) USER MANUAL (SSDL-3201RGB) 1 TABLE OF CONTENTS INTRODUCTION...3 MAIN FEATURES...3 UNPACKING...3 SAFETY WARNING...3 PANEL REVIEW...4 INSTALLATION AND SETTING...4 1. MULTI-FIXTURES CONNECTION...4 2. LAMP

More information

BSL HELIOS USERS GUIDE

BSL HELIOS USERS GUIDE BSL HELIOS USERS GUIDE 1. Product Introduction: 1.1 Before unpack the fixture, pls make sure that the packing is in good condition, following items will be found in the box: - The fixture - This users

More information

6X3W TRICOLOUR LEDS COMPACT PROJECTOR

6X3W TRICOLOUR LEDS COMPACT PROJECTOR 6X3W TRICOLOUR LEDS COMPACT PROJECTOR USER GUIDE 10147 - Version 2 / 05-2015 English MINICUBE-6TCb - 6x3W tricolour LEDs compact projector 1 - Safety information Important safety information This unit

More information

User Instructions. Warning! To prevent or reduce the risk of electrical shock or fire, do not expose this unit to rain or moisture.

User Instructions. Warning! To prevent or reduce the risk of electrical shock or fire, do not expose this unit to rain or moisture. General Information User Instructions Unpacking: Thank you for purchasing the by American DJ. Every has been thoroughly tested and has been shipped in perfect operating condition. Carefully check the shipping

More information

1. Before you Begin Introduction Setup Operation Technical Information Technical Specifications...

1. Before you Begin Introduction Setup Operation Technical Information Technical Specifications... User Manual TABLE OF CONTENTS 1. Before you Begin... 3 What is Included... 3 Unpacking Instructions... 3 Text Conventions... 3 Icons... 3 Safety Notes... 4 2. Introduction... 5 Product Overview... 5 3.

More information

MH-X50+ LED spot moving head. user manual

MH-X50+ LED spot moving head. user manual MH-X50+ LED spot moving head user manual Musikhaus Thomann e.k. Treppendorf 30 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0 E-mail: info@thomann.de Internet: www.thomann.de 02.08.2012 Table

More information

DJ SCAN 250 XT. Table of contents

DJ SCAN 250 XT. Table of contents DJ SCAN 250 XT Table of contents 1. Safety instructions... 3 2. Operating determinations... 4 3. Description of the device... 5 4. Installation... 6 4.1Fitting/Exchanging the lamp... 6 4.2 Inserting/Exchanging

More information

Color Ground 12T 16 A USER MANUAL 5 APPENDIX 5.1 TROUBLE SHOOTING 5.2 MAINTENANCE LED MODULE. Version 1.0 SITUATION CAUSE ACTION 5 APPENDIX

Color Ground 12T 16 A USER MANUAL 5 APPENDIX 5.1 TROUBLE SHOOTING 5.2 MAINTENANCE LED MODULE. Version 1.0 SITUATION CAUSE ACTION 5 APPENDIX 5 APPENDIX 5. TROUBLE SHOOTING LED MODULE SITUATION CAUSE ACTION Can not receive DMX signal ) DMX signal cable error 2) Signal connection error 3) The input signal IC damaged 4) DMX address error ) Check

More information

User Manual. Snapshot. Use on Dimmer. Outdoor Use. Sound Activated DMX. Master/Slave. Auto-ranging Power Supply. Replaceable Fuse.

User Manual. Snapshot. Use on Dimmer. Outdoor Use. Sound Activated DMX. Master/Slave. Auto-ranging Power Supply. Replaceable Fuse. Snapshot Use on Dimmer Outdoor Use Sound Activated DMX Master/Slave Auto-ranging Power Supply Replaceable Fuse User Serviceable Duty Cycle User Manual 3000 N 29 th Ct, Hollywood, FL 33020 U.S.A. (800)

More information

LED Spot 300W. Please read this user manual before your operation

LED Spot 300W. Please read this user manual before your operation LED Spot 300W Please read this user manual before your operation 1. Introduction 2. General Guideline 3. Safety Instructions 4. Cleaning and Maintenance 5. Technical Parameters 6. DMX Channels 7. Remark

More information

USER MANUAL Table of Contents

USER MANUAL Table of Contents USER MANUA Table of Contents Safety Information. 3 Specifications.. 4 Main Power Connection.. 5 DMX-512 Connection...... 5 DMX Profile... 7 Main Control Menu... 8 Rigging the Fixture.10 Cleaning & Maintenance...10

More information

PRO PAR HEX 12. User Manual

PRO PAR HEX 12. User Manual Caution: For your safety, please read this user manual carefully before initial use! DISCLAIMER: Stage Light Company known as SLC in this document believes that the information contained in this manual

More information

PROFESSIONAL SCANNER USER S MANUAL

PROFESSIONAL SCANNER USER S MANUAL PROFESSIONAL SCANNER USER S MANUAL (VER1.0) KEEP THIS MANUAL FOR FUTURE NEEDS For your own safety, please read this user manual carefully before installing the device. K eep thi s devi ce aw ay f rom rai

More information

Waterfall 250 Pro. Elation Professional 4295 Charter Street Los Angeles, Ca Rev. 12/28/05

Waterfall 250 Pro. Elation Professional 4295 Charter Street Los Angeles, Ca Rev. 12/28/05 Waterfall 250 Pro Elation Professional 4295 Charter Street Los Angeles, Ca 90058 Rev. 12/28/05 www.elationlighting.com Elation Professional 2 Elation Professional 3 Contents 1. General Information 3 a.

More information

User Instructions. Warning! To prevent or reduce the risk of electrical shock or fire, do not expose this unit to rain or moisture.

User Instructions. Warning! To prevent or reduce the risk of electrical shock or fire, do not expose this unit to rain or moisture. General Information User Instructions Unpacking: Thank you for purchasing the by American DJ. Every has been thoroughly tested and has been shipped in perfect operating condition. Carefully check the shipping

More information

PRODUCT SPECIFICATIONS

PRODUCT SPECIFICATIONS FOS RGB Fan 1 PRODUCT SPECIFICATIONS TECHNICAL SPECIFICATION Voltage: 110/240 Volt AC, 50/60 Hz. Power Consumption: 180 Watt. Light Source: 792x 0,2 Watt RGB SMD 5050 LEDs. Effects: LEDs are separated

More information

Instruction Manual. from software version 1.0 (instruction version 1.3) Internet:

Instruction Manual. from software version 1.0 (instruction version 1.3)   Internet: Instruction Manual from software version 1.0 (instruction version 1.3) email: service@glp.de Internet: http://www.glp.de GLP German Light Production (V1.3) 1 Table of contents 1 Description of Device...

More information

1. BEFORE YOU BEGIN INTRODUCTION CONTROL FEATURES... 5 Additional Features... 5 PRODUCT OVERVIEW SETUP... 6

1. BEFORE YOU BEGIN INTRODUCTION CONTROL FEATURES... 5 Additional Features... 5 PRODUCT OVERVIEW SETUP... 6 User Manual TABLE OF CONTENTS 1. BEFORE YOU BEGIN... 3 WHAT IS INCLUDED... 3 UNPACKING INSTRUCTIONS... 3 MANUAL CONVENTIONS... 3 ICONS... 3 SAFETY INSTRUCTIONS... 4 2. INTRODUCTION... 5 CONTROL FEATURES...

More information

User Instructions. Warning! To prevent or reduce the risk of electrical shock or fire, do not expose this unit to rain or moisture.

User Instructions. Warning! To prevent or reduce the risk of electrical shock or fire, do not expose this unit to rain or moisture. General Information User Instructions Unpacking: Thank you for purchasing the by American DJ. Every has been thoroughly tested and has been shipped in perfect operating condition. Carefully check the shipping

More information

Outdoor Stage PAR 12 4W Quad IR RGBW, 12 3W Quad IR UV LED PAR. user manual

Outdoor Stage PAR 12 4W Quad IR RGBW, 12 3W Quad IR UV LED PAR. user manual Outdoor Stage PAR 12 4W Quad IR RGBW, 12 3W Quad IR UV LED PAR user manual Musikhaus Thomann Thomann GmbH Hans-Thomann-Straße 1 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0 E-mail: info@thomann.de

More information

USER MANUAL Table of Contents

USER MANUAL Table of Contents USER MANUAL Table of Contents Safety Information. 3 Specifications.. 4 Main Power Connection.. 5 DMX-512 Connection...... 5 Main Control Menu... 6 Fixture Addressing... 6 Manual Mode...7 Save Scene...7

More information

LED Spot Light User Manual Model LS90 Big Dipper Laser Science And Technology Co., Ltd Please read this manual carefully before operating

LED Spot Light User Manual Model LS90 Big Dipper Laser Science And Technology Co., Ltd Please read this manual carefully before operating LED Spot Light User Manual Model:LS90 Big Dipper Laser Science And Technology Co., Ltd REV: 1.01 Please read this manual carefully before operating Warnings: Please check the package whether any damage

More information

PLL2210MW LED Monitor

PLL2210MW LED Monitor PLL2210MW LED Monitor USER'S GUIDE www.planar.com Content Operation Instructions...1 Safety Precautions...2 First Setup...3 Front View of the Product...4 Rear View of the Product...5 Quick Installation...6

More information

American DJ. User Instructions. Model: Mega Bar 50RGB

American DJ. User Instructions. Model: Mega Bar 50RGB Specifications Model: SPECIFICATIONS: Working Position: Any safe working position Voltage: 90V ~ 240V, 50/60Hz LEDs: 126 x 10mm LEDs (42 Red, 42 Green, 42 Blue) Power Draw: 18W Beam Angle: 40 Degree Fuse:

More information

Outdoor Stage PAR 12 4 W Quad, 12 3 W UV IR LED PAR. user manual

Outdoor Stage PAR 12 4 W Quad, 12 3 W UV IR LED PAR. user manual Outdoor Stage PAR 12 4 W Quad, 12 3 W UV IR LED PAR user manual Musikhaus Thomann Thomann GmbH Hans-Thomann-Straße 1 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0 E-mail: info@thomann.de Internet:

More information

ETC Quick Guide. Source Four LED Profile

ETC Quick Guide. Source Four LED Profile ETC Quick Guide Source Four LED Profile Overview For complete information and step-by-step instructions, see the Source Four LED Profile User Manual. ETC documentation can be downloaded at www.etcconnect.com.

More information

MB150 USER MANUAL (V2.00) Elektralite 70 Sea Lane, Farmingdale N.Y U.S.A. Tel (+1) Fax (+1)

MB150 USER MANUAL (V2.00) Elektralite 70 Sea Lane, Farmingdale N.Y U.S.A. Tel (+1) Fax (+1) MB150 USER MANUAL (V2.00) Elektralite 70 Sea Lane, Farmingdale N.Y. 11735 U.S.A. Tel (+1)-516-249-3662 Fax (+1)-516-249-8870 www.myelektralite.com For your own safety, please read this user manual carefully

More information

Design Wash 1400E. Elation Professional 6122 S. Eastern Ave Los Angeles, Ca Rev. 08/08/2008-visage

Design Wash 1400E. Elation Professional 6122 S. Eastern Ave Los Angeles, Ca Rev. 08/08/2008-visage Design Wash 1400E Elation Professional 6122 S. Eastern Ave Los Angeles, Ca. 90040 Rev. 08/08/2008-visage CONTENTS 1. General Information 4 a. Introduction. 4 b. Customer Support. 3 c. Warranty Registration...

More information