1 RF Noise Source Operation Manual Version 2.04 June 3, 2016
2 SPECIFICATIONS Frequency... Maximum output level... Output flatness... (at max output level) Impedance... Displayed level... Repeatability... Level adjustment... Input power... Output connector... Size, Weight... 5 MHz to 2.15 GHz. at least -90 dbm/hz (+50 dbmv) total power khz bandwidth MHz bandwidth MHz bandwidth ±1.5 db 5 MHz to 1 GHz ±2.0 db 1 GHz to 2 GHz ±3.0 db 5 MHz to 2.15 GHz 75 Ohm (standard), 50 Ohm (optional) relative ±0.5 db 30 db, in steps of 0.1, 1.0 or 10 db 120/240 VAC Front panel Type BNC or F female (standard) Rear panel Type SMA, N, BNC, or F female (optional) 7.3 W x 3.7 H x 9.25 D, 4.5 lbs. (18.5cm) x (9.4cm) x (23.5cm), 2.04 kg Recommended duration between conformance inspections: two years Specifications subject to change without notice Page 2 of 11
3 1. Introduction The Applied Instruments Model RF Noise Source generates a high quality RF noise signal for laboratory and field use. Features 5 MHz to 2.15 GHz frequency range 30 db of adjustment range in 0.1 db steps Adjustable step size in addition to direct numeric entry On/off pulsed modulation modes in three speeds Settable reference point Remote control via RS232 and/or USB port Standard Accessories AC Line cord 30 patch cable USB cable Options Rack-mount kit 75 Ohm or 50 Ohm output impedance Rear panel RF output connector (Type SMA, N, BNC, or F) BNC 75 to 50 ohm matching pad (75 ohm male BNC to 50 ohm female BNC) External RF amplifier External band-pass filters, inquire for frequencies Page 3 of 11
4 2. Safety and Service 2.1. Symbols Used The following symbols are used in this manual and/or marked on the instrument. Hazardous areas on the instrument are marked with this symbol. Consult this manual to learn the nature of the hazard and proper actions for safe operation. Indicates an earth ground terminal Indicates possibility of electric shock Indicates a protective conductor terminal 2.2. Safety Instructions Read and follow all instructions in this manual. Risk of electrical shock exists if the unit is opened when AC is connected. Cleaning: Unplug and turn unit off before cleaning. Clean with a dry cloth only. Use only the cord supplied with the unit or an equivalent cord rated for at least 1.4 Amps and containing a protective earth ground conductor. Servicing should be done by qualified service technicians only. Use of the instrument in a manner not consistent with the instructions in this manual may impair the safety features and lead to damage or injury AC Operation When operating the instrument from AC power, adhere to these rules: 1. Warning: The appliance coupler (AC cord) is used as the disconnect device. Do not position the instrument so that it is difficult to operate the appliance coupler. 2. Use only the cord supplied with the unit or an equivalent cord rated for at least 1.4 Amp and containing a protective earth ground conductor. 3. Warning: The AC plug shall be connected to a mains socket outlet with a protective earthing connection Operating Conditions This instrument is intended for use under the following environmental conditions. Use outside of these conditions may result in safety hazards, incorrect operation, or damage. 1. Indoor use 2. Altitude <= 2000 meters 3. Ambient temperature 10 C to 50 C 4. Relative humidity <80% up to 31 C, <50% at 40 C 5. AC voltage +/- 10% of nominal (some temporary over-voltage tolerated) 6. Transient voltage spikes <2500 Vp 7. Pollution degree 2 or less, non-conductive pollution Page 4 of 11
5 2.5. Water Ingress and Mounting Do not set up or use unit where liquids or other conductive materials are used. Ensure that no liquids are spilled into the unit. If water or other conductive material enters the enclosure, immediately turn off the unit and unplug it. Contact a qualified technician or return the unit to Applied Instruments for repair. 3. Servicing Instructions With normal use, the only servicing of the unit that should be expected is recalibration. A calibration period of two years is recommended. All service should be performed by a qualified technician only. WARNING: Risk of shock is present when the cover is removed and AC power is present. Be sure to disconnect from AC before opening the unit. 4. Front Panel Operations After a brief start-up message indicating the firmware version number, the main screen is displayed: REF MOD RATE SET STEP RF OFF MAX db (at min) MODULATION OFF Step Size 1.0 db RF ON STEP UP STEP DOWN SET UP The soft keys displayed on the LCD screen are positioned next to their corresponding buttons. The screen is NOT a touch screen, you have to press the button next to the function shown on the screen. RF ON/OFF Press the RF ON soft key to turn the RF output on. The key label will change to RF OFF to indicate the action when the button is pressed a second time. The present state is shown in the center of the screen. REFERENCE MODE The RF level is displayed in db in one of three ways: 1) db down from the maximum output Page 5 of 11
6 2) db up from the minimum level 3) db up or down from a set reference level You select the reference mode by pressing the REF soft key. The selected mode appears just above the level number in the middle of the screen. When changing the reference mode, the level itself does not change, but the displayed number will change according to the new mode. REFERENCE LEVEL When the REF reference mode is selected, you can set the reference level by pressing the SET REF key. This key is not available or displayed when either the MIN or the MAX modes are selected. When you press the SET REF key, the displayed level changes to zero (the actual output level does not change). Now you can adjust the level either up or down from this new reference level. Page 6 of 11
7 LEVEL ADJUSTMENT There are several ways to change the RF output level: If you know what numeric value you want, you may use the numeric keypad to enter the number and press the ENTER key when finished. Or, you may use the arrow keys to adjust any digit of the displayed number either up or down. Use the left and right keys to move the cursor between the digits. The level will change as you press the up and down arrow keys. This method allows easy adjustment in 10 db, 1 db or 0.1 db steps. Finally, you may use the STEP UP and STEP DOWN soft keys to step up or down at the defined step size. STEP SIZE The step size is shown at the bottom of the screen and may be set by pressing the SET STEP key, entering the step size with numeric keys and pressing ENTER. MODULATION The modulation feature cycles the RF on and off at a 50% duty cycle at three selectable rates: SLOW 10 seconds per cycle MED 1 second per cycle FAST 50 cycles per second NONE no cycling Press the MOD RATE soft key to select the desired rate. SETUP Press the SET UP soft key to display the setup screen. This screen lets you enter the desired screen contrast value with the numeric pad or press ENTER and adjust with the arrow buttons. Press ENTER when finished. SETUP Contrast: 50 PRE SET DIAG EXIT The contrast is temperature compensated and should be legible at any operating temperature once it is set. Press PRESET to return all settings to the factory default settings. Press EXIT to return to the main screen. The DIAG soft key allows access to a diagnostic screen intended for service technicians only. Page 7 of 11
8 BACKLIGHT The screen backlight has four settings: off, low, medium and high. When turned on with AC power, the backlight is set to high. The backlight setting may be changed with the +/- key. You must press the key twice to change the backlight. The first press is interpreted as either the + or the and used to change the sign of number being entered. Press it repeatedly until the desired backlight setting is obtained. 5. Rear Panel Functions The rear panel contains the following items: 1) AC power input jack 2) RS232 DB-9 connector 3) USB connector 4) Power option switch 5) Rear RF output connector hole AC Power Input The AC power input jack accepts a standard IEC power cord and may be plugged into 120V or 240V AC power, 50 or 60 Hz. A United States cord is standard; other cords are available on request. RS232 Connection A standard PC style serial cable with a DB-9 connector may be used to connect a PC to the RS232 port of the. This enables the remote control functions to be used. USB Connector The USB port provides the same remote functions as the RS232 port. A standard USB cable is included. Power Option Switch For use in automated test applications, the power option switch enables the instrument to automatically power up whenever AC power is applied. This is useful when installing the as part of an equipment rack: the unit will power up when the rack is turned on. Rear RF output connector hole A rear panel RF output connector is available as an option instead of the front panel connector for the RF output. This is also useful in automated test applications. Connector options include SMA, N, BNC, or F female (specify 75 Ohm or 50 Ohm desired impedance). Page 8 of 11
9 6. Remote Operations The may be controlled remotely through the RS232 or USB serial ports. If using the USB port, a standard cable is provided, and a USB virtual com port driver must be installed on your PC. The driver makes the appear as another com port on your PC. You may then use any terminal emulation software to communicate with the. NOTE: The driver is available from: If you are using an actual RS232 port, you will need a standard straight-thru 9 pin serial cable (not a null-modem cable). This can be obtained from Applied Instruments or any computer outlet. Set the serial port on your PC to 9600 baud, 8 data bits, no parity, 1 stop bit, flow control none. The command set conforms to the SCPI standard and is described below. See for more information on the SCPI standard. The commands are described below in the standard SCPI notation. Commands are terminated with a carriage return character. Most commands have a query form (trailing question mark) that returns the present value. Syntax notes: 1. Commands parts in brackets below are optional. 2. Uppercase denotes required spelling, lower case optional spelling. 3. Either case is accepted. 4. Boolean values may be entered as OFF, ON, 0 or 1. 0 is the same as OFF RF On/Off OUTPut[:STATe] <Boolean> Turns the RF output on or off. OUTPut[:STATe]? Returns 0 or 1. Examples: output:state on outp on output off 6.2. Level Control [OUTPut:]ATTenuation <value> [OUTPut:]ATTenuation? Sets the attenuation in db Returns the attenuation in db The output power level is set to the maximum output minus the attenuation value used here. This corresponds to the MAX reference type on the front panel operations. The MIN and REF types are not supported via remote commands. The step size and stepping functions are also not supported by the remote commands. Examples: Output:attenuation 10.5 attenuation 20 att 5.1 Page 9 of 11
10 6.3. Modulation [SOURce:]PULM[:STATe] <Boolean> Turns the modulation on or off [SOURce:]PULM[:STATe]? Returns the modulation state (0 or 1). [SOURce:]PULM:[INTernal:]FREQuency <value>sets the modulation frequency in Hz. [SOURce:]PULM:[INTernal:]FREQuency? Return the modulation frequency in Hz. The supports only three pulse frequencies: slow=0.1 Hz, med=1 Hz and fast=50 Hz. The SCPI command uses a numeric value; the translates the given frequency into the closest supported frequency. Examples: Source:pulm:state on Pulm:frequency 50 Pulm:freq? Pulm off 6.4. Error Reporting The system error query command is supported for a few types of errors: SYSTem:ERRor? Returns one of the following: 0, "No error" -100, "Command error" -350, "Queue overflow" 6.5. SCPI Required Commands The following commands are implemented as required by the SCPI standard but have no real function in the. *CLS *ESE *ESE? *ESR? *IDN? *OPC *OPC? *RST *SRE *SRE? *STB? *TST? *WAI Clear Status Command Standard Event Status Enable Command Standard Event Status Enable Query Standard Event Status Register Query Identification Query Operation Complete Command Operation Complete Query Reset Command Service Request Enable Command Service Request Enable Query Read Status Byte Query Self Test Query Wait to continue Command The has no overlapped commands so the *OPC, *WAI and *OPC commands are not needed Multiple Commands SCPI allows multiple commands to be strung together on the same line separated by semicolons. This feature is not implemented in the. Page 10 of 11
11 WARRANTY The Applied Instruments is warranted against defects in materials and workmanship for a period of twelve months. Applied Instruments agrees to repair or replace any assembly or component found to be defective under normal use during this period. Our obligation under this warranty is limited solely to repairing the instrument proved to be defective within the scope of the warranty when returned to the factory. Transportation to the factory is to be prepaid by the customer. Authorization by Applied Instruments is required prior to shipment. Applied Instruments assumes no liability for secondary charges or consequential damages and, in any event, Applied Instruments liability for breach of warranty under any contract shall not exceed the purchase price of the instrument shipped, and against which a claim is made. Any application recommendation made by Applied Instruments for the use of its products are based upon tests believed to be reliable, but Applied Instruments makes no warranty of the results to be obtained. This warranty is in lieu of all other warranties, expressed or implied, and no representative or person is authorized to represent or assume for Applied Instruments any liability in connection with the sale of our products other than that set forth herein. Applied Instruments, Inc Elmwood Avenue Indianapolis, IN USA Tel: +1 (317) Tel (Toll free USA): (800) Fax: +1 (317) Page 11 of 11
Noise Detector ND-1 Operating Manual
Noise Detector ND-1 Operating Manual SPECTRADYNAMICS, INC 1849 Cherry St. Unit 2 Louisville, CO 80027 Phone: (303) 665-1852 Fax: (303) 604-6088 Table of Contents ND-1 Description...... 3 Safety and Preparation
More informationMENU EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free
Instruction Manual Model 2584-31 Combiner May 2011, Rev. A RF MONITOR GAIN = -15 MENU MODEL 2584 COMBINER CROSS TECHNOLOGIES INC. ALARM REMOTE POWER EXECUTE Data, drawings, and other material contained
More informationPAM-1840 Preamplifier Operation Manual
PAM-1840 Preamplifier Operation Manual 1 TABLE OF CONTENTS INTRODUCTION 3 GENERAL INFORMATION 4 SPECIFICATIONS 4 OPERATING INSTRUCTIONS 5 MAINTENANCE 6 2 INTRODUCTION BEFORE APPLYING POWER Review this
More informationModel /29S RF Splitter
Instruction Manual Model 1584-29/29S RF Splitter March 2013, Rev. 0 LNB VOLTAGE A B MODEL 1584 COMBINER CROSS TECHNOLOGIES INC. GND+DC ON Data, drawings, and other material contained herein are proprietary
More informationUSB-TG124A Tracking Generator User Manual
USB-TG124A Tracking Generator User Manual Signal Hound USB-TG124A User Manual 2017, Signal Hound, Inc. 35707 NE 86th Ave La Center, WA 98629 USA Phone 360.263.5006 Fax 360.263.5007 This information is
More informationCS x1 RS-232 Computer Controlled Video Switcher. Instruction Manual
CS-1600 16x1 RS-232 Computer Controlled Video Switcher Instruction Manual Thank you for purchasing one of our products. Please read this manual before using this product. When using this product, always
More informationModel P/03P Upconverters
Instruction Manual Model 2005-02P/03P Upconverters October 2013, Rev H 2005 TEST UPCONVERTER GHz 100MHz10MHz 1MHz C KU 70 140 IF IN GAIN DC POWER +DC IN +15V, 200 ma RF OUT DC ALARM LO IF FREQUENCY J1
More informationInstruction Manual Model # Block Upconverter
Instruction Manual Model 2115-278# Block Upconverter August 2018, Rev. A MODEL 2115 UPCONVERTER CROSS TECHNOLOGIES INC. EXT 10MHZ ALARM POWER Data, drawings, and other material contained herein are proprietary
More informationMONITOR POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free
Instruction Manual Model 2099-10xx 10MHz Frequency Source April 2014, Rev. H MENU INTERNAL LEVEL = +10dBm MONITOR POWER 1 2 MODEL 2099 FREQUENCY SOURCE CROSS TECHNOLOGIES INC. ALARM OVEN REMOTE EXECUTE
More informationDISTRIBUTION AMPLIFIER
MANUAL PART NUMBER: 400-0045-005 DA1907SX 1-IN, 2-OUT VGA/SVGA/XGA/UXGA DISTRIBUTION AMPLIFIER USER S GUIDE TABLE OF CONTENTS Page PRECAUTIONS / SAFETY WARNINGS... 2 GENERAL...2 GUIDELINES FOR RACK-MOUNTING...2
More informationQCA9-33 Active Combiner
Product Manual QCA9-33 Active Combiner April 13, 2012 Table of Contents Table of Contents... 2 Overview... 3 Specifications... 4 Installation... 5 Basic Setup... 5 16-Channel Operation... 5 16-64 Channel
More informationInstruction Manual Model BlockUpconverter
Instruction Manual Model 2115-55 BlockUpconverter June 2009 - Rev. 0 MODEL 2115 UPCONVERTER CROSS TECHNOLOGIES INC. EXT 10MHZ ALARM POWER Data, drawings, and other material contained herein are proprietary
More informationQDA4-44 RF Amp/Combiner
Product Manual QDA4-44 RF Amp/Combiner May 17, 2012 Table of Contents Table of Contents... 2 Overview... 3 Specifications... 4 Installation... 5 Basic Setup... 5 Rack Mounting... 6 RK2 Dual Rack Kit with
More informationMENU EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free
Instruction Manual Model 2016-1250 Downconverter May 2009 Rev A F=2501.750 G=+25.0 MENU MODEL 2016 DOWNCONVERTER CROSS TECHNOLOGIES INC. ALARM REMOTE POWER EXECUTE Data, drawings, and other material contained
More informationLEVEL ADJUST POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free
Instruction Manual Model 1200-75 Amplifier August 2012, Rev. A LEVEL ADJUST POWER MODEL 1200 AMPLIFIER CROSS TECHNOLOGIES, INC. Data, drawings, and other material contained herein are proprietary to Cross
More informationAssembly Level Service Guide
Assembly Level Service Guide This guide describes how to service the Agilent 53150A, 53151A, and 53152A Microwave Frequency Counters. The information in this guide applies to instruments having the number
More informationVector Network Analyzer TTR503A/TTR506A USB Vector Network Analyzer Preliminary Datasheet. Subject to change.
Vector Network Analyzer TTR503A/TTR506A USB Vector Network Analyzer Preliminary Datasheet. Subject to change. Applications Academic/Education Design, development and manufacturing of passive and active
More informationARS x4 MATRIX SWITCHER Instruction Manual
ARS-8400 8x4 MATRIX SWITCHER Instruction Manual Thank you for purchasing one of our products. Please read this manual before using this product. When using this product, always follow the instructions
More informationLEVEL ADJUST POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free
Instruction Manual Model 1200-07 Amplifier September 2010 Rev A MONITOR J1 LEVEL ADJUST POWER MODEL 1200 AMPLIER CROSS TECHNOLOGIES, INC. Data, drawings, and other material contained herein are proprietary
More informationTABLE OF CONTENTS Page PRECAUTIONS / SAFETY WARNINGS...2 GENERAL...2 RACK MOUNT SAFETY GUIDELINES...2 INSTALLATION...2 CLEANING...2 FCC / CE NOTICE...
MANUAL PART NUMBER: 400-0099-001 PRODUCT REVISION: 0 MX2456RM 6-IN, 1-OUT VGA & AUDIO SWITCHER USER S GUIDE TABLE OF CONTENTS Page PRECAUTIONS / SAFETY WARNINGS...2 GENERAL...2 RACK MOUNT SAFETY GUIDELINES...2
More information6170 Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free
Instruction Manual Model 2115-202 Upconverter November 2011, Rev. C MODEL 2115 UPCONVERTER CROSS TECHNOLOGIES INC. EXT 10MHZ ALARM POWER Data, drawings, and other material contained herein are proprietary
More informationclipping; yellow LED lights when limiting action occurs. Input Section Features
ELX-1A Rack-Mount Mic/Line Mixer Four inputs, one output in a single rack space Very-highery-high-quality audio performance High reliability Extensive filtering circuitry and shielding protect against
More informationDTV742 Installation Quick Start Guide
DTV742 Installation Quick Start Guide The Wegener Model DTV742 8VSB 4-Channel Multiplexor receives VHF/UHF broadcast HDTV signals and provides output ASI streams for connection to cable system QAM modulators.
More informationKramer Electronics, Ltd. USER MANUAL. Model: VS x 1 Sequential Video Audio Switcher
Kramer Electronics, Ltd. USER MANUAL Model: VS-120 20 x 1 Sequential Video Audio Switcher Contents Contents 1 Introduction 1 2 Getting Started 1 2.1 Quick Start 2 3 Overview 3 4 Installing the VS-120 in
More informationST-4000 SIGNAL LEVEL METER
ST-4000 SIGNAL LEVEL METER Table of Contents Features / Specifications.... 1 Keypad Illustration....... 2 Keypad Controls.... 2 Getting Started: Powering the Meter.... 3 Quick Use Instructions.. 3 Main
More informationInstructions. P MHz 1X/10X Passive Probe
Instructions P2100 100 MHz 1X/10X Passive Probe 071-0774-01 071077401 Copyright Tektronix, Inc. All rights reserved. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information
More informationRS232 settings are internally definable via jumper blocks, to accommodate interfacing with a wide range of control products.
Appendix C RS232 Protocol RS232 settings are internally definable via jumper blocks, to accommodate interfacing with a wide range of control products. Baud rate 9600 or 19200 Echo status AUTO or REQUEST
More informationAES-402 Automatic Digital Audio Switcher/DA/Digital to Analog Converter
Broadcast Devices, Inc. AES-402 Automatic Digital Audio Switcher/DA/Digital to Analog Converter Technical Reference Manual Broadcast Devices, Inc. Tel. (914) 737-5032 Fax. (914) 736-6916 World Wide Web:
More informationSTAGE SETTER-8. User Instructions. Elation Professional 4295 Charter Street Los Angeles Ca
Introduction STAGE SETTER-8 User Instructions Introduction: Thank you for purchasing the Elation Professional Stage Setter 8. To optimize the performance of this product, please read these operating instructions
More informationKramer Electronics, Ltd. USER MANUAL. Model: VM Video Component Distributor
Kramer Electronics, Ltd. USER MANUAL Model: VM-1045 Video Component Distributor Contents Contents 1 Introduction 1 2 Getting Started 1 2.1 Quick Start 1 3 Overview 3 4 Your VM-1045 Video Component Distributor
More informationModular Block Converter Systems
Modular Block Converter Systems The Modular Block Converter System eliminates system downtime and maximizes ease of repair by providing fully modular systems for up conversion or down conversion. Critical
More informationUSER MANUAL. DV-HSW-41 HDMI 4x1 SWITCHER LIT Bergen Boulevard, Woodland Park, NJ Tel FAX Web
USER MANUAL DV-HSW-41 HDMI 4x1 SWITCHER 244 Bergen Boulevard, Woodland Park, NJ 07424 Tel 973-785-4347 FAX 973-785-3318 Web www.fsrinc.com LIT1372 PROPRIETARY INFORMATION All information in this manual
More informationTABLE OF CONTENTS Page PRECAUTIONS / SAFETY WARNINGS...2 GENERAL...2 RACK MOUNT SAFETY GUIDELINES...2 INSTALLATION...2 CLEANING...2 FCC / CE NOTICE...
MANUAL PART NUMBER: 400-0129-001 PRODUCT REVISION: 0 MX2436RM 6-IN, 1-OUT COMPOSITE VIDEO & AUDIO SWITCHER USER S GUIDE TABLE OF CONTENTS Page PRECAUTIONS / SAFETY WARNINGS...2 GENERAL...2 RACK MOUNT SAFETY
More informationSAWM60 AUDIO/VIDEO MODULATOR
SAWM60 LIMITED WARRANTY Holland Electronics LLC, warrants that the product enclosed with this Limited Warranty statement will conform to the manufacturer s specifications and be free of defects in the
More informationAES-404 Digital Audio Switcher/DA/Digital to Analog Converter
Broadcast Devices, Inc. AES-404 Digital Audio Switcher/DA/Digital to Analog Converter Technical Reference Manual Broadcast Devices, Inc. Tel. (914) 737-5032 Fax. (914) 736-6916 World Wide Web: www.broadcast-devices.com
More information10MHz Source/Inserter
Instruction Manual Model 2099-218 10MHz Source/Inserter Redundant 18V January 2011, Rev. A RX 0.32 A TX 0.86 A REF ON REF OFF MENU MODEL 2099 SOURCE/INSERTER CROSS TECHNOLOGIES INC. PS1 PS2 REMOTE ALARM
More informationTR6102HD HDTV/DVD/COMPONENT VIDEO TO RGBHV TRANSCODER USER S GUIDE
MANUAL PART NUMBER: 400-0031-003 PRODUCT REVISION: 1 HDTV/DVD/COMPONENT VIDEO TO RGBHV TRANSCODER USER S GUIDE INTRODUCTION Thank you for your purchase of the Transcoder. We are certain that you will find
More informationLIGHT COPILOT II. elationlighting.com Internet:
LIGHT COPILOT II E-mail: info@ elationlighting.com Internet: http://www.elationlighting.com 1 Introduction Thank you for your purchase of the LIGHT COPILOT II. The LIGHT COPILOT II is an intelligent lighting
More informationINSTALLATION MANUAL. Model: HDD. ATSC/QAM Digital to Analog Demodulator
INSTALLATION MANUAL Model: HDD ATSC/QAM Digital to Analog Demodulator Caution: These servicing instructions are for use by qualified service personnel only. To reduce the risks of electric shock, do not
More informationST-4000D SIGNAL LEVEL METER
ST-4000D SIGNAL LEVEL METER Rev 100606 Table of Contents Features / Specifications.... 1 Keypad Illustration....... 2 Keypad Controls.... 2 Getting Started: Powering the Meter...... 3 Quick Use Instructions.....
More informationInstruction Manual Model Downconverter
Instruction Manual Model 2016-1351 Downconverter August 2010, Rev. A F=512 G=+0.0 MENU MODEL 2016 DOWNCONVERTER CROSS TECHNOLOGIES INC. ALARM REMOTE POWER EXECUTE Data, drawings, and other material contained
More informationOperator s Manual. Ultegra. Health Scale. Fairbanks Scales by Fairbanks Scales Inc. All rights reserved. Revision 5 06/07
Operator s Manual Ultegra Health Scale Fairbanks Scales 2007 by Fairbanks Scales Inc. All rights reserved 50735 Revision 5 06/07 Amendment Record Ultegra Health Scale 50735 Manufactured by Fairbanks Scales
More information3GSDI Audio Embedder
1080P 3GSDI Audio Embedder GEF-SDI-AUDE User Manual www.gefenpro.com ASKING FOR ASSISTANCE Technical Support: Telephone (818) 772-9100 (800) 545-6900 Fax (818) 772-9120 Technical Support Hours: 8:00 AM
More informationAC182A 8 Input x 8 Output S-Video Matrix Switch with Audio
Heading AC180A 8 Input x 8 Output Composite Video Matrix Switch with Audio MARCH 2005 AC180A AC182A AC182A 8 Input x 8 Output S-Video Matrix Switch with Audio CUSTOMER SUPPORT INFORMATION Order toll-free
More informationDTV744 Installation Quick Start Guide
DTV744 Installation Quick Start Guide The Wegener Model DTV744 8VSB 4-Channel Demodulator receives VHF/UHF broadcast HDTV 8VSB signals and provides output ASI streams for connection to an advanced cable
More informationINSTALLATION MANUAL Model: HMDD. ATSC/QAM Digital Mini Demodulator
INSTALLATION MANUAL Model: HMDD ATSC/QAM Digital Mini Demodulator 1 PACKAGE CONTENTS This package contains: One HMDD ATSC/QAM Mini Demodulator One HMDD Installation Manual PRODUCT DESCRIPTION The HMDD
More informationHMA-860H AGILE MODULATOR
HMA-860H AGILE MODULATOR LIMITED WARRANTY Holland Electronics LLC, warrants that the product enclosed with this Limited Warranty statement will conform to the manufacturer s specifications and be free
More informationDUAL/QUAD DISPLAY CONTROLLER Operation Manual
DUAL/QUAD DISPLAY CONTROLLER Operation Manual Model PXD524 MicroImage Video Systems division of World Video Sales Co., Inc PO Box 331 Boyertown, PA 19512 Phone 610-754-6800 Fax 610-754-9766 sales@mivs.com
More informationInstruction Manual Model Block Downconverter
Instruction Manual Model 3116-7890 Block Downconverter May 2016, Rev. 0 MENU 8.40-1.55 GHZ G=+10.0 REF AUTO-I MODEL 3116 DOWNCONVERTER CROSS TECHNOLOGIES INC. REMOTE ALARM POWER EXECUTE Data, drawings,
More informationHD-1603 Single Input MPEG-4 DVB-T HD Encoder/Modulator User Guide and Install Manual
ZyCastR digi-mod HD Range digi-mod HD-1603 www.digi-modbyzycast.com HD-1603 Single Input MPEG-4 DVB-T HD Encoder/Modulator User Guide and Install Manual Table of Contents www.digi-modbyzycast.com Safety
More informationipump 622 Streaming Media Decoder Installation Quick Start Guide
ipump 622 Streaming Media Decoder Installation Quick Start Guide General Information Unpacking and Inspection The Wegener ipump 622 Enterprise Media Server is an integrated satellite receiver and video
More informationINSTRUCTION MANUAL. MODEL Downconverter
INSTUCTION MANUAL MODEL 2016-123 Downconverter Data, drawings, and other material contained herein are proprietary to Cross Technologies, Inc., but may be reproduced or duplicated without the prior permission
More informationIntegrator s Guide Avalon
Integrator s Guide Avalon HD Component Video / Digital Audio Matrix Switch 2 Table of Contents Table of Contents... 2 Introduction... 3 Features:... 3 Installation... 4 Unpacking... 4 Front Panel Protective
More informationZIG-POEPRO-70A. HDBaseT HDMI Extender
ZIG-POEPRO-70A HDBaseT HDMI Extender 1 Important Safety Instructions 1. Do not use this product near water. 2. Do not block any ventilation openings. Install in accordance with the manufacturer s instructions.
More informationDIGITAL STROBOSCOPE OPERATION MANUAL. Model : DT-2239A
DIGITAL STROBOSCOPE Model : DT-2239A Your purchase of this DIGITAL STROBOSCOPE marks a step forward for you into the field of precision measurement. Although this STROBOSCOPE is a complex and delicate
More informationEnglish. User Manual sub8 Subwoofer SUBWOOFER. Supporting your digital lifestyle
English User Manual sub8 Subwoofer U SUBWOOFER Supporting your digital lifestyle Table of Contents Important Safety Precautions........ 2 Introduction / What s in the Box?...... 3 Front & Rear Panels............
More informationPRO-HDMI2HD. HDMI to SDI/3G-HD-SD Converter. User Manual. Made in Taiwan
PRO-HDMI2HD HDMI to SDI/3G-HD-SD Converter User Manual Made in Taiwan rev.1008 103 Quality Circle, Suite 210 Huntsville, Alabama 35806 Tel: (256) 726-9222 Fax: (256) 726-9268 Email: service@pesa.com Safety
More informationDA IN 1-OUT LINE DRIVER WITH EQUALIZATION + AUDIO USER S GUIDE
MANUAL PART NUMBER: 400-0430-001 1-IN 1-OUT LINE DRIVER WITH UALIZATION + AUDIO USER S GUIDE TABLE OF CONTENTS Page PRECAUTIONS / SAFETY WARNINGS... 2 GENERAL...2 GUIDELINES FOR RACK-MOUNTING...2 INSTALLATION...2
More informationPRO-ScalerHD2V HDMI to VGA & Audio Scaler Converter. User s Guide. Made in Taiwan
PRO-ScalerHD2V HDMI to VGA & Audio Scaler Converter User s Guide Made in Taiwan Congratulations for owning a gofanco product. Our products aim to meet all your connectivity needs wherever you go. Have
More informationAES Channel Digital/Analog Audio Switcher/DA/Digital to Analog Converter
Broadcast Devices, Inc. AES-408 8 Channel Digital/Analog Audio Switcher/DA/Digital to Analog Converter Technical Reference Manual Broadcast Devices, Inc. Tel. (914) 737-5032 Fax. (914) 736-6916 World Wide
More informationUSER INSTRUCTIONS MODEL CSI-200 COAXIAL SYSTEM INTERFACE
USER INSTRUCTIONS MODEL CSI-200 COAXIAL SYSTEM INTERFACE 9350-7676-000 Rev B, 5/2001 PROPRIETARY NOTICE The RTS product information and design disclosed herein were originated by and are the property of
More information1X4 HDMI Splitter with 3D Support
AV Connectivity, Distribution And Beyond... VIDEO WALLS VIDEO PROCESSORS VIDEO MATRIX SWITCHES EXTENDERS SPLITTERS WIRELESS CABLES & ACCESSORIES 1X4 HDMI Splitter with 3D Support Model #: SPLIT-HDM3D-4
More informationOLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide
OLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide Limited Warranty One Year Limited Warranty All Noyes products are warranted against defective material and
More informationHD-CM HORIZON DIGITAL CABLE METER
HD-CM OFF! Max RF i/p = +17dBm 75Ω Max AC/DC i/p = 120Vrms MENU INPUT ON HORIZON DIGITAL CABLE METER Horizon Global Electronics Ltd. Unit 3, West Side Flex Meadow Harlow, Essex CM19 5SR Phone: +44(0) 1279
More informationDA1909 COMPUTER VIDEO LINE DRIVER WITH EQUALIZATION USER S GUIDE
MANUAL PART NUMBER: 400-0108-002 PRODUCT REVISION: 1 COMPUTER VIDEO LINE DRIVER WITH EQUALIZATION USER S GUIDE INTRODUCTION Altinex appreciates your purchase of the Line Driver. We are sure you will find
More informationArtisan Technology Group is your source for quality new and certified-used/pre-owned equipment
Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment FAST SHIPPING AND DELIVERY TENS OF THOUSANDS OF IN-STOCK ITEMS EQUIPMENT DEMOS HUNDREDS OF MANUFACTURERS SUPPORTED
More informationInstruction Manual Model Block Upconverter
Instruction Manual Model 3115-73 Block Upconverter April 2013, Rev. 0 MENU 7.1-7.3GHZ G=+10.0 REF AUTO MODEL 3115 UPCONVERTER CROSS TECHNOLOGIES INC. REMOTE ALARM POWER EXECUTE Data, drawings, and other
More informationSCALE & WEIGHT DISPLAYS
The MICRO SERIES SCALE & WEIGHT DISPLAYS LARGE DIGIT MODELS Mighty-5S DPM MODELS Micro-S & Mighty-1S Mighty-1S Micro-S ELECTRO-NUMERICS, INC. Introduction The Electro-Numerics family of Digital Panel Meters
More informationConcert Series ORDERCODE D3470 ORDERCODE D3471 ORDERCODE D3472 D3470 D3471 D3472
Concert Series ORDERCODE D3470 ORDERCODE D3471 ORDERCODE D3472 D3470 D3471 D3472 Congratulations! You have bought a great, innovative product from DAP Audio. The DAP Audio Concert Series brings excitement
More informationInstruction Manual Fixed Speed Vortex Mixer Analog Vortex Mixer Digital Vortex Mixer Pulsing Vortex Mixer
Instruction Manual Fixed Speed Vortex Mixer Analog Vortex Mixer Digital Vortex Mixer Pulsing Vortex Mixer Table of Contents Package Contents............ 1 Warranty............ 1 Installation............
More informationR&S ZVA-Zxx Millimeter-Wave Converters Specifications
R&S ZVA-Zxx Millimeter-Wave Converters Specifications Data Sheet Version 19.00 CONTENTS Definitions... 3 General information... 4 Specifications... 5 Test port... 5 Source input (RF IN)... 5 Local oscillator
More informationAdvanced Test Equipment Rentals ATEC (2832)
E stablished 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) Technical Datasheet Scalar Network Analyzer Model 8003-10 MHz to 40 GHz The Giga-tronics Model 8003 Precision Scalar
More informationKramer Electronics, Ltd. USER MANUAL. Model: VM-10xl. Video Audio Distribution Amplifier
Kramer Electronics, Ltd. USER MANUAL Model: VM-10xl Video Audio Distribution Amplifier Contents Contents 1 Introduction 1 2 Getting Started 1 2.1 Quick Start 1 3 Overview 3 4 Your VM-10xl Video Audio Distribution
More information1080P. 3GSDI Audio De-Embedder. GEF-SDI-AUDD User Manual.
1080P 3GSDI Audio De-Embedder GEF-SDI-AUDD User Manual www.gefenpro.com ASKING FOR ASSISTANCE Technical Support: Telephone (818) 772-9100 (800) 545-6900 Fax (818) 772-9120 Technical Support Hours: 8:00
More informationUtility Amplifier GA6A Model
Utility Amplifier GA6A Model Installation and Use Manual 2004 Bogen Communications, Inc. All rights reserved. Specifications subject to change without notice. 54-5757-03D 1503 NOTICE: Every effort was
More informationVK-P10SE WARRANTY REGISTRATION FORM
VK-P10SE WARRANTY REGISTRATION FORM Unit Serial Number: Customer Name: Address: Date of Purchase: Purchased From: Dealer Name: Address: IMPORTANT NOTE: In order to receive the full five-year product warranty,
More informationAgilent 87075C Multiport Test Set Product Overview
Agilent 87075C Multiport Test Set Product Overview A complete 75 ohm system for cable TV device manufacturers Now, focus on testing, not reconnecting! For use with the Agilent 8711 C-Series of network
More informationModel R177M and R177S Baseband Switch
Model R177M and R177S Baseband Switch Installation Guide P/N 1340192 082304 Monroe Electronics 100 Housel Ave Lyndonville NY 14098-0535 800-821-6001 585-765-2254 fax 585-765-9330 www.monroe-electronics.com
More informationHD-1600 Single Input MPEG-4 DVB-T HD Encoder/Modulator User Guide and Install Manual
digi-mod HD Range digi-mod HD-1600 www.resi-linx.com HD-1600 Single Input MPEG-4 DVB-T HD Encoder/Modulator User Guide and Install Manual Table of Contents Safety Precautions 2 Package Contents 2 Product
More informationSLS-50 Stabilized Laser Source. User s Manual. Shineway Technologies, Inc. All rights reserved.
SLS-50 Stabilized Laser Source User s Manual Shineway Technologies, Inc. All rights reserved. Safety Instructions The WARNING sign denotes a hazard. It calls attention to a procedure, practice, or the
More informationMetal Electrode Meter
Metal Electrode Meter INSTRUCTION MANUAL FOR Metal Electrode Meter MODEL 2900 Serial # Date PO Box 850 Carlsborg, WA 98324 U.S.A. 360-683-8300 800-426-1306 FAX: 360-683-3525 http://www.a-msystems.com Version
More informationKramer Electronics, Ltd.
Kramer Electronics, Ltd. Preliminary USER MANUAL Model: VM-1110xl Balanced Audio Distributor Contents Contents 1 Introduction 1 2 Getting Started 1 2.1 Quick Start 2 3 Overview 3 4 Your VM-1110xl Balanced
More informationMP-204D Digital/Analog Stereo Monitor Panel
MP-204D Digital/Analog Stereo Monitor Panel Videoquip Research Limited 595 Middlefield Road, Unit #4 Scarborough, Ontario, Canada. MIV 3S2 (416) 293-1042 1-888-293-1071 www.videoquip.com 1 Videoquip MP-204D
More informationRS232 settings are internally definable via jumper blocks, to accommodate interfacing with a wide range of control products.
Appendix C RS232 Protocol RS232 settings are internally definable via jumper blocks, to accommodate interfacing with a wide range of control products. Baud rate 96ØØ or 192ØØ Echo status AUTO or REQUEST
More informationTest Systems. Typical JFW Systems. Matrix switches Programmable assemblies Switch assemblies Manual attenuator assemblies Power divider assemblies
Test Systems This section of our catalog showcases some standard JFW test systems. However, we understand that everyone s system requirements are unique. For this reason, we can design a system to suit
More informationElement 78 MPE-200. by Summit Audio. Guide To Operations. for software version 1.23
Element 78 MPE-200 by Summit Audio Guide To Operations for software version 1.23 TABLE OF CONTENTS IMPORTANT SAFETY AND GROUNDING INSTRUCTIONS COVER 1. UNPACKING AND CONNECTING...3 AUDIO CONNECTIONS...4
More informationT L Audio. User Manual C1 VALVE COMPRESSOR. Tony Larking Professional Sales Limited, Letchworth, England.
T L Audio User Manual C1 VALVE COMPRESSOR Tony Larking Professional Sales Limited, Letchworth, England. Tel: 01462 490600. International +44 1462 490600. Fax: 01462 490700. International +44 1462 490700.
More informationFor warranty service, please contact Microframe at: A technician will gladly assist you.
Your Microframe System is warranted against failure due to defects in workmanship or material for a period of one (1) year from the date of purchase. Microframe Corporation will repair or replace any defective
More informationVPM2. Operator's Manual
VPM2 Operator's Manual Whip Mix Corporation 361 Farmington Ave. P.O. Box 17183 Louisville, KY 40217-0183 USA 502-637-1451 800-626-5651 Fax 502-634-4512 www.whipmix.com Features The Whip Mix VPM2 is designed
More informationDragonfly Quad. User Manual V1.4. Order code: EQLED101
Dragonfly Quad User Manual V1.4 Order code: EQLED101 Safety advice WARNING FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START-UP! Before your initial start-up, please
More informationMX2416RM/MX2414RM 6/(4) - IN, 1 - OUT VGA/MAC SWITCHER USER S GUIDE
MANUAL PART NUMBER: 400-0020-003 PRODUCT REVISION: 0 MX2416RM/MX2414RM 6/(4) - IN, 1 - OUT VGA/MAC SWITCHER USER S GUIDE INTRODUCTION Thank you for purchasing the MX2416RM Switcher. We are sure you will
More informationL-BAND MONITOR Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free
Instruction Manual Model 3116-77#-1200 Block Downconverter February 2014, Rev. 0 MENU F = 7812.600 MHZ REF = INT L-BAND MONITOR MODEL 3116 DOWNCONVERTER CROSS TECHNOLOGIES INC. REMOTE ALARM POWER EXECUTE
More informationInstruction Manual Model
Instruction Manual Model 4115-267 Ka-Band Block Upconverter May 2015, Rev. C Data, drawings, and other material contained herein are proprietary to Cross Technologies, Inc., but may be reproduced or duplicated
More informationMultiMode FOMs -ST and -SMA
FEBRUARY 1996 MD640A-ST-R2 MD640A-SMA-R2 MD640AE-ST-R2 MD640AE-SMA-R2 MultiMode FOMs -ST and -SMA POWER TD RD RTS CD MultiMode FOM Test Modes Remote Normal Local CUSTOMER SUPPORT INFORMATION Order toll-free
More informationSyncGen. User s Manual
SyncGen User s Manual 1 IMPORTANT SAFETY INSTRUCTION READ FIRST This symbol, whenever it appears, alerts you to the presence of uninsulated dangerous voltage inside the enclosure-voltage that may be sufficient
More informationIntegrator s Guide Concord
Integrator s Guide Concord HD Component Video / Composite Video / Analog Audio Matrix Switch with Cat5 outputs 2 3 Table of Contents Table of Contents... 3 Introduction... 4 Features:... 4 Installation...
More informationFrequency. Range. HP 83751A/B: 2 GHz to 20 GHz HP 83752A/B: 10 MHz to 20 GHz. Standard 10 MHz timebase: f10 ppm
Frequency Range HP 83751A/B: 2 GHz to 20 GHz HP 83752A/B: 10 MHz to 20 GHz Timebase Stability Standard 10 MHz timebase: f10 ppm High stability timebase (Option le5): Accuracy = Calibration &Aging rate
More informationOPERATOR MANUAL OSD351 FIBRE OPTIC CCTV TRANSMITTER CARD
OPERATOR MANUAL OSD351 FIBRE OPTIC CCTV TRANSMITTER CARD OSD351 FIBRE OPTIC CCTV TRANSMITTER CARD Document No:10103701 PAGE 2 C O N T E N T S 1. TECHNICAL SUMMARY...4 1.1 BRIEF DESCRIPTION...4 1.2 TECHNICAL
More informationInstalling the FOREST SHUTTLE S / L
2 Installing the FOREST SHUTTLE S / L 1 Assemble the track 2 Install the brackets and fix the track onto the brackets 3 Do not attach the drapery yet. Attach the drapery only after the end positions have
More informationMarshall Electronics. Broadcast A/V Division VAC-HT12-KIT. 4K HDBaseT Extender Kit. User Manual
Marshall Electronics Broadcast A/V Division VAC-HT12-KIT 4K HDBaseT Extender Kit User Manual VAC-HT12-KIT Manual Table of Contents Introduction... 3 Features... 3 Package Contents... 3 Specifications...
More information