Enclosing the STB Island

Size: px
Start display at page:

Download "Enclosing the STB Island"

Transcription

1 Enclosing the STB Island Open System Requirement All Advantys STB modules meet CE mark requirements for open equipment and should be installed in an enclosure that meets NEMA 250 type 1 requirements and IP 20 requirements conforming to IEC 529. The enclosure should be designed to prevent: unauthorized access personal injury resulting from access to live parts The specific environmental conditions under which the modules must operate should be considered in planning for the enclosure. Special consideration should be given to hazardous locations where a potentially explosive atmosphere (see page 35) may exist. NOTE: The majority of Advantys STB modules are certified for use in explosive environments. Refer to ATEX/FM Certified STB Modules (see page 37) for a complete list of modules. Size of the Enclosure The size of the enclosure is determined by the number of modules that will makeup the island. One NIM and a maximum of 32 I/O modules are permitted per island which can be: standard Advantys STB optional preferred optional standard CANopen In addition, PDMs, and an EOS or termination plate must be included in determining the total size of the island Standard Module Dimensions Advantys STB modules come in three different sizes and the dimensions for each of the sizes are listed in the following table. Module size Width of module alone Height of module in base Depth of module in base with field connectors mm (.55 in.) mm (5.05 in.) 75.5 mm (2.97 in.) mm (.73 in.) mm (5.05 in.) 75.5 mm (2.97 in.) 2-PDM 18.4 mm (.73 in.) mm (5.45 in) 79.5 mm (3.13 in.) mm (1.11 in.) mm (5.05 in.) 70.1 mm (2.76 in) These depth and height dimensions do not take into account the dimensions of external power equipment, preferred modules and/or standard CANopen devices /2009

2 The size and type of base for each of the Advantys STB modules is listed in the table on the following page. STB Modules Size & Base Type The following table lists the size and required base for each of the Advantys STB modules. Model Size Base Model Size Base Analog Input Modules Analog Output Modules /

3 Model Size Base Model Size Base STB ACI STB XBA 2000 STB ACO STB XBA 2000 STB ACI STB XBA 1000 STB ACO STB XBA 2000 STB ACI STB XBA 1000 STB ACO STB XBA 1000 STB ACI STB XBA 2000 STB ACO STB XBA 1000 STB ACI STB XBA 2000 STB AVO STB XBA 2000 STB ART STB XBA 1000 STB AVO STB XBA 1000 STB AVI STB XBA 2000 STBAVO STB XBA 1000 STB AVI STB XBA 1000 STB AVO STB XBA 1000 STB AVI STB XBA STB AVI STB XBA STB AVI STB XBA Digital Input Modules Digital Output Modules STB DAI STB XBA 2000 STB DAO STB XBA 2000 STB DAI STB XBA 2000 STB DAO STB XBA 2000 STB DAI STB XBA 2000 STB DDO STB XBA 1000 STB DDI STB XBA 1000 STB DDO STB XBA 1000 STB DDI STB XBA 1000 STB DDO STB XBA 1000 STBDDI STB XBA 1000 STB DDO STB XBA 1000 STB DDI STB XBA 1000 STB DDO STB XBA 1000 STB DDI STB XBA 1000 STB DDO STB XBA 1000 STB DDI STB XBA 3000 STB DDO STB XBA STB DRC STB XBA STB DRA STB XBA 3000 Power Distribution Modules Special Purpose Modules STB PDT STB XBA 2200 STB EHC STB XBA 3000 STB PDT STB XBA 2200 STB EPI STB XBA 2000 STB PDT STB XBA 2200 STB EPI STB XBA 3000 STB PDT STB XBA 2200 STB XBE STB XBA STB XBE STB XBA /2009

4 Spacing Requirements Adequate clearance must be maintained between the modules installed in the enclosure and surrounding fixed objects such as wire ducts and inside surfaces. The following two illustrations show the spacing requirements within an enclosure /

5 Mounting The island is mounted on one or more 35 mm wide DIN carrier rails. For EMC compliance, a metal DIN rail must be attached to a flat metal mounting surface or mounted on an EIA rack or in a NEMA cabinet enclosure. The physical backplane for the island is established by placing a NIM and a sequence of interlocked base units on the DIN rail (see page 18). The standard DIN rail is 35 mm x 15 mm deep. For DIN rail mounting requirements (see page 74) Wiring Wiring must not obstruct the 100 mm (3.94) of free air space above and below the island segment. All wires must be secured to prevent undue load or strain on the STB modules. As shown in the side view (above), all leads from a harness or cable channel must be dressed with a service loop to reduce strain on the module. Thermal Considerations For proper heat dissipation, allow a minimum clearance of 100 mm (3.94 in) above and below each island segment. The vent openings on top and bottom of the modules must not be obstructed. Listed below are some worst-case values for estimating the wattage dissipation when you plan the cooling for your system and cabinet enclosure: Module Type Module Width Worst-case Wattage Value inputs size W size W size /2009

6 Module Type Module Width Worst-case Wattage Value outputs size W size W size 3 special I/O size W size 3 CANopen extension size W EOS size W BOS size W auxiliary power supply size W DC PDM size W AC PDM size W NIM The values above assume elevated bus voltage, elevated field-side voltage and maximum load currents. Typical wattage values are often considerably lower /

HART STB Multiplexer Applications Guide

HART STB Multiplexer Applications Guide HART S1B40735 4/2013 HART STB Multiplexer Applications Guide 4/2013 S1B40735.01 www.schneider-electric.com The information provided in this documentation contains general descriptions and/or technical

More information

IP 20 distributed inputs/outputs Advantys STB. Catalog January

IP 20 distributed inputs/outputs Advantys STB. Catalog January IP 0 distributed inputs/outputs Catalog January 0 Contents Distributed I/O Solution Open and Modular System b Presentation, description.................................. pages to 8 b Dimensions, references.......................................

More information

Advantys STB Standard INTERBUS Network Interface Module Applications Guide. 890USE17400 Version 2.0

Advantys STB Standard INTERBUS Network Interface Module Applications Guide. 890USE17400 Version 2.0 Advantys STB Standard INTERBUS Network Interface Module Applications Guide 890USE17400 Version 2.0 31004624 01 31004624 01 2 Table of Contents Safety Information.................................... 5 About

More information

STBXBA1000 Podstawa moduł WE/WY FORMAT I

STBXBA1000 Podstawa moduł WE/WY FORMAT I Dane produktu Charakterystyki Uzupełnienie Zgodność produktu Szerokość Masa produktu Środowisko Oferta zrównoważonego rozwoju Status oferty zrównoważonego rozwoju RoHS (kod daty: RRTT) REACh Contractual

More information

Automation & Control Advantys STB IP20 Distributed I/O

Automation & Control Advantys STB IP20 Distributed I/O Automation & Control Advantys STB IP0 Distributed I/O Catalog October 07 us. This international site allows you to access all the Telemecanique brand products in just clicks via comprehensive range data-sheets,

More information

Advantys Configuration Software

Advantys Configuration Software Advantys Configuration Software 33004243 05/2012 Advantys Configuration Software Quick Start Guide for Former Advantys Lite Users 05/2012 33004243.04 www.schneider-electric.com The information provided

More information

Advantys STB DATA SHEET. Advantys STB Output Module. Description. Features

Advantys STB DATA SHEET. Advantys STB Output Module. Description. Features Advantys STB Advantys STB Output Module DATA SHEET Description The Advantys model STBDAO5260 Digital Output Module provides 2 isolated discrete output points that operate on a 115 VAC power source. The

More information

Advantys STB Standard Profibus DP Network Interface Module Applications Guide. 890USE17300 Version 2.0

Advantys STB Standard Profibus DP Network Interface Module Applications Guide. 890USE17300 Version 2.0 Advantys STB Standard Profibus DP Network Interface Module Applications Guide 890USE17300 Version 2.0 31002957 01 31002957 01 2 Table of Contents Safety Information....................................

More information

DATA SHEET. The Advantys model STBDAI5260 Digital Input Module provides 2 isolated discrete input points that operate on a 115 VAC power source.

DATA SHEET. The Advantys model STBDAI5260 Digital Input Module provides 2 isolated discrete input points that operate on a 115 VAC power source. Advantys STB Advantys STB Input Module DATA SHEET Description The Advantys model STBDAI5260 Digital Input Module provides 2 isolated discrete input points that operate on a 115 VAC power source. Features

More information

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil Product datasheet Characteristics LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil Product data sheet Characteristics LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

Advantys STB Standard DeviceNet Network Interface Module Applications Guide. 890USE Version 2.0

Advantys STB Standard DeviceNet Network Interface Module Applications Guide. 890USE Version 2.0 Advantys STB Standard DeviceNet Network Interface Module Applications Guide 890USE175 00 Version 2.0 31003680 01 01 2 Table of Contents Safety Information.................................... 5 About the

More information

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC Product datasheet Characteristics LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC Price* : 86.25 GBP Main Range Product name Product or component type Device short name Contactor application Utilisation category

More information

STBART0200K standard analog input kit STB - 2 I - 15 bits + sign

STBART0200K standard analog input kit STB - 2 I - 15 bits + sign Product data sheet Characteristics STBART0200K standard analog input kit STB - 2 I - 15 bits + sign Main Range of product Product or component type Kit composition Analogue input type Analogue input number

More information

LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil Product datasheet Characteristics LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O Characteristics motion servo drive - Lexium 23 - single phase 200...255 V - 1 kw - I/O Main Range of product Product or component type Device short name Complementary Format of the drive Network number

More information

LC3D180AV7 TeSys D - star delta starter - 3 x 3P (3 NO) - 18 A V AC coil

LC3D180AV7 TeSys D - star delta starter - 3 x 3P (3 NO) - 18 A V AC coil Characteristics TeSys D - star delta starter - 3 x 3P (3 NO) - 18 A - 400 V AC coil Main Range Product name Product or component type Device short name Contactor application Utilisation category Device

More information

Operating Manual (Edition 04/2004) sinamics. Line Reactors SINAMICS G130

Operating Manual (Edition 04/2004) sinamics. Line Reactors SINAMICS G130 Operating Manual (Edition 04/2004) sinamics Line Reactors SINAMICS G130 Contents 1. Safety Information 2 2. General 5 3. Mechanical Installation 6 4. Electrical Installation 8 5. Technical Specifications

More information

LC3D115M7 TeSys D - star delta starter - 3 x 3P (3 NO) A V AC coil

LC3D115M7 TeSys D - star delta starter - 3 x 3P (3 NO) A V AC coil Characteristics TeSys D - star delta starter - 3 x 3P (3 NO) - 115 A - 220 V AC coil Main Range Product name Product or component type Device short name Contactor application Utilisation category Device

More information

LC1D50AFE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

LC1D50AFE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil Product data sheet Characteristics LC1D50AFE7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

OP5. Preprogrammed, configurable controller for simple applications

OP5. Preprogrammed, configurable controller for simple applications sect. pos. revision 3 020 08 2007 OP5 Preprogrammed, configurable controller for simple applications Optigo 5 is a new preprogrammed, configurable controller intended for DIN-mounting that can be set to

More information

Premium and Advantys STB on MB/TCP Advantys STB with Advantys FTB and Altivar on CANopen System User Guide [source code]

Premium and Advantys STB on MB/TCP Advantys STB with Advantys FTB and Altivar on CANopen System User Guide [source code] 33003500.01 Premium and Advantys STB on MB/TCP Advantys STB with Advantys FTB and Altivar on CANopen System User Guide [source code] Contents Application Example - Source Code...3 Typical applications...4

More information

LC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

LC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil Product data sheet Characteristics LC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

Modicon STB IP 20 distributed inputs/outputs

Modicon STB IP 20 distributed inputs/outputs IP 0 distributed inputs/outputs Catalog 00 A full range of catalogs for...... IP 0 distributed inputs/outputs Catalog 00 Detection Automation Automation Operator dialog Motion and Drives & Global Detection

More information

LC1D150B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A - 24 V AC 50/60 Hz coil

LC1D150B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A - 24 V AC 50/60 Hz coil Product data sheet Characteristics LC1D150B7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

Datasheet - SRB301LC 24VAC/DC

Datasheet - SRB301LC 24VAC/DC 25.02.2016-18:05:23h Datasheet - SRB301LC 24VAC/DC Guard door monitors and Safety control modules for Emergency Stop applications / General Purpose safety controllers (Series PROTECT SRB) / SRB301LC Preferred

More information

AS09..S 3-pole Contactors - Spring Terminals

AS09..S 3-pole Contactors - Spring Terminals 4 kw 5 hp AS09..S 3-pole Contactors - Spring AC Operated Description - 3-pole contactors with spring terminals, - N.C. or N.O. built-in auxiliary contact, - Rail-mounted, no tools required, - Additional

More information

SINAMICS G130. dv/dt filter plus Voltage Peak Limiter. Operating Instructions 03/2013 SINAMICS

SINAMICS G130. dv/dt filter plus Voltage Peak Limiter. Operating Instructions 03/2013 SINAMICS SINAMICS G130 Operating Instructions 03/2013 SINAMICS s dv/dt filter plus Voltage Peak Limiter Safety information 1 General 2 SINAMICS SINAMICS G130 Operating Instructions Mechanical installation 3 Electrical

More information

For applications from 0.25 to 5 HP, the MD60 is a simple AC Microdrive that can be panel mounted as well as wall or machine mounted.

For applications from 0.25 to 5 HP, the MD60 is a simple AC Microdrive that can be panel mounted as well as wall or machine mounted. For applications from 0.25 to 5 HP, the MD60 is a simple AC Microdrive that can be panel mounted as well as wall or machine mounted. N223 Reliance Electric s MD60 AC Drive is ready to operate out-of-the-box!

More information

I/A Series Hardware Fieldbus Communications Module, FCM10Ef

I/A Series Hardware Fieldbus Communications Module, FCM10Ef Product Specifications I/A Series Hardware ieldbus Communications odule, C10Ef The C10Ef ieldbus Communications odule is a fiber optic communications interface which allows the DIN rail mounted ieldbus

More information

I/A Series Hardware Fiber Optic LAN Converter

I/A Series Hardware Fiber Optic LAN Converter I/A Series Hardware PSS 21H-7F3 B4 The provides bidirectional conversion between coaxial and fiber optic media. The converter is compatible with existing I/A Series system hardware, utilizes industry standard

More information

LC1D09M7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

LC1D09M7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil Bảng thông số sản phẩm Đặc diểm LC1D09M7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

llen-bradley 194R-HM4-NFPA3

llen-bradley 194R-HM4-NFPA3 Technical Data Rotary Disconnect Switch Specifications Bulletin Number 194R Topic Page Product Line Overview 2 General Specifications Fuse Description 12 Approximate Dimensions 14 Additional Resources

More information

ALLEN BRADLEY TIMING RELAY

ALLEN BRADLEY TIMING RELAY ALLEN BRADLEY TIMING RELAY Configuration Details Product: 700-HS12BA1 Description: 700-HS General Purpose Square Base Timing Relay, On Delay Timer, 1.0 to 180 seconds, DPDT, 120V AC 50/60Hz CONTROL RELAY

More information

Ordering details. Approval. Classification

Ordering details. Approval. Classification Datasheet - SRB 301MC-24V Guard door monitors and Safety control modules for Emergency Stop applications / General Purpose safety controllers (Series PROTECT SRB) / SRB 301MC Fit for signal evaluation

More information

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100 DATASHEET - NZMH2-A100 Circuit-breaker, 3p, 100A Part no. NZMH2-A100 Catalog No. 259099 Similar to illustration Delivery program Product range Circuit-breaker Protective function System and cable protection

More information

LC1D09B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V AC coil

LC1D09B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V AC coil Product data sheet Characteristics LC1D09B7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

Connecting cables for valves, Sub-D Type codes

Connecting cables for valves, Sub-D Type codes Type codes NEBV C S1 G 44 K Function NEBV Connecting cables for valves Product design Standard C Easy to clean design Connection technology, left, field device side S1 S7 Sub-D socket Sub-D HD socket Cable

More information

LC1D25G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A V AC coil

LC1D25G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A V AC coil Product data sheet Characteristics LC1D25G7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

Datasheet - SRB-E-201ST

Datasheet - SRB-E-201ST 27.04.2016-16:36:21h Datasheet - SRB-E-201ST Multi-function safety modules / SRB-E-201ST STOP 0 Function 1 oder 2-channel control Start button / Auto-start Monitoring two-hand control panels to EN 574

More information

LC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A V AC coil

LC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A V AC coil Product data sheet Characteristics LC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

Rexroth IndraDrive Fc Compact, high-performance standard frequency converters

Rexroth IndraDrive Fc Compact, high-performance standard frequency converters Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics Service Rexroth IndraDrive Fc Compact, high-performance standard frequency converters Simply a better drive 2

More information

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/ > 8 channels for 2-wire HART transmitters > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit monitoring for each field circuit > Module

More information

GV3P80 TeSys GV3P thermal-magn motor circuit breaker 70-80A EverLink

GV3P80 TeSys GV3P thermal-magn motor circuit breaker 70-80A EverLink Characteristics TeSys GV3P thermal-magn motor circuit breaker 70-80A EverLink Main Range Product name Device short name Product or component type Device application Trip unit technology Complementary Poles

More information

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module Helvar Data is subject to change without notice. www.helvar.com i Contents Section Page Introduction 1 Installation 2 1. Attach

More information

Generator protection relay

Generator protection relay Page 1 Issued: April 1999 Status: New Data subject to change without notice Features Off-the-shelf generator protection relay for small and medium sized power generators Three-phase time overcurrent and

More information

LC3D80B7 TeSys D - star delta starter - 3 x 3P (3 NO) - 80 A - 24 V AC coil

LC3D80B7 TeSys D - star delta starter - 3 x 3P (3 NO) - 80 A - 24 V AC coil Characteristics TeSys D - star delta starter - 3 x 3P (3 NO) - 80 A - 24 V AC coil Price* : 4058.00 USD has not been replaced. Please contact your customer care center for more information. Main Range

More information

Magnecraft General Purpose Relays 782 Power Series SPDT 20 A; DPDT 15 A

Magnecraft General Purpose Relays 782 Power Series SPDT 20 A; DPDT 15 A 72 Power Series SPDT 20 A; DPDT 15 A UL listed when used with proper Magnecraft sockets The 72 Plug-in Power relays offer clear or full-feature covers with multiple mounting options and accessories. Feature

More information

Location. Electrical. Loads. 2-wire mains-rated, 0.5 mm² to 1.5 mm² Max. length: 300 m (with 1.5 mm² cable). Example: Belden 8471.

Location. Electrical. Loads. 2-wire mains-rated, 0.5 mm² to 1.5 mm² Max. length: 300 m (with 1.5 mm² cable). Example: Belden 8471. Product Description Installation and User Guide Transistor Dimmer (454) The DIN rail mounted 454 is a fourchannel transistor dimmer that can operate in one of two modes: leading edge or trailing edge.

More information

LED MODULES READYLINE DL

LED MODULES READYLINE DL LED MODULES READYLINE DL BUILT-IN MODULE LED-MODULE READYLINE DOWNLIGHT DL WU-M-538 / WU-M-539 / WU-M-540 Typical Applications Downlights Replacement for CFL DIRECT MAINS CONNECTION REDUCED FLICKER HIGH

More information

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control IEC Contactors and Starters. XT Family of Contactors Contactors and Starters Product Description The Eaton XT contactors and starters includes nonreversing and reversing contactors, overload relays and

More information

Single-Output 2000 W

Single-Output 2000 W Single-Output 2000 W 6571A-6575A Front panel and analog control of output voltage and current Fast, low-noise outputs Fan-speed control to minimize acoustic noise Protection features to ensure DUT safety

More information

Assembly. Front view. LEDs. Parametrization interface. Power Bus

Assembly. Front view. LEDs. Parametrization interface. Power Bus otation Speed Monitor Features Assembly 1-channel signal conditioner 2 V DC supply Input for 2- or -wire sensors Input frequency 10 mhz... 50 khz elay contact output Start-up override and restart inhibit

More information

Vaya Cove, Color. Data sheet. Philips Lighting Rev Burlington Woods Drive Burlington, MA 01803

Vaya Cove, Color. Data sheet. Philips Lighting Rev Burlington Woods Drive Burlington, MA 01803 Vaya Cove, Color Philips Vaya Cove is a cost effective and reliable color-changing light fixture for interior use. Vaya Cove is designed for cove and accent lighting applications. Three lengths, standard

More information

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit DATASHEET - S811+N66N3S Delivery program Soft starter, 66 A, 200-600 V AC, Us= 24 V DC, with control unit, Frame size N Part no. S811+N66N3S Catalog No. 168978 Eaton Catalog No. S811PLUSN66N3S EL-Nummer

More information

Rexroth IndraDrive Fc Compact, high-performance standard frequency converters

Rexroth IndraDrive Fc Compact, high-performance standard frequency converters Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics Service Rexroth IndraDrive Fc Compact, high-performance standard frequency converters Simply a better drive 2

More information

BL67 electronic module 2 analog inputs for thermoelements BL67-2AI-TC

BL67 electronic module 2 analog inputs for thermoelements BL67-2AI-TC Independent of the type of fieldbus and connection technology used Protection class IP67 LEDs indicate status and diagnostic Electronics galvanically separated from the field level via optocouplers 2 analog

More information

Fieldbus Components Section K

Fieldbus Components Section K ection K This section covers our full range of connection technology for Profibus DP and Profibus P available in cabinet or field mount formats and for harzardous locations. We also supply a complete range

More information

High performance circuit breakers

High performance circuit breakers Series High performance Description The high performance MCB offers a compact solution to circuit protection. The devices are DIN rail mounted. The is available with application-specific trip characteristics

More information

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A and 3DPT, 10 A UL Listed when used with proper Magnecraft s The 750R series octal base, plug-in relays offer clear or full-feature covers with multiple mounting options and accessories. 750R 750R Full-Feature

More information

263 Series LED Bargraph Indicator and Controllers

263 Series LED Bargraph Indicator and Controllers 263 Series LED Bargraph Process Control Water Treatment High resolution 51 segment LED Bargraph for easy reading Accuracy 1% Red display Vertical or Horizontal mounting & stackable Connection Diagrams

More information

Installation instructions Ex frames

Installation instructions Ex frames General information Installation and maintenance: For European member countries of GENELEC shall standard EN 60079-14 and EN 60079-17 be considered. For countries members of IECEx shall standard IEC 60079-14

More information

Level Measurement silometer FMC 420, FMC 423

Level Measurement silometer FMC 420, FMC 423 Technical Information TI 077F/00/en Level Measurement silometer FMC 420, FMC 423 For connecting to capacitance probes or Deltapilot S hydrostatic probes Main applications The is used for continuous level

More information

Gamma instabus. Technical product information

Gamma instabus. Technical product information Gamma instabus Technical product information Universal dimmer N 554D31, 4 x 300 VA / 1x 1000 VA, AC 230 V Universal dimmer N 554D31 Control of dimmable lamps, including LED without minimum load Output

More information

T5, T8, TC-L. PC T5 PRO lp W V 50/60/0 Hz, HO. Electronic ballasts Linear lamps T5, T8 and compact lamps TC-L

T5, T8, TC-L. PC T5 PRO lp W V 50/60/0 Hz, HO. Electronic ballasts Linear lamps T5, T8 and compact lamps TC-L T, T8, TC-L Electronic ballasts PC T PRO lp 80 W 0 0 V 0/0/0 Hz, HO L D,1 0, 1 side fixing feature side fixing feature ø,1 defined lamp warm start is 1. s constant light output independent of fluctuations

More information

Fibre optic router for TP/FT-10 LRW-112PP

Fibre optic router for TP/FT-10 LRW-112PP Fibre optic router for TP/FT-10 LRW-112PP Lo n Wo r k s to fibre optic link, point-to-point applications The LRW-112PP router offers an easy way to extend the distance between LONWORKS 78 kbit/s TP/FT

More information

IndyGo Facility Upgrades Project 35671EE

IndyGo Facility Upgrades Project 35671EE SECTION 260553 IDENTIFICATION FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Identification for raceways. 2. Identification of power and control cables. 3. Identification for

More information

Trusted 40 Channel 120 Vac Digital Input FTA

Trusted 40 Channel 120 Vac Digital Input FTA ICSTT-RM290F-EN-P (PD-T8824) Trusted Product Overview The Trusted 40 Channel 120 Vac Digital Input Field Termination Assembly (FTA) T8824 is designed to act as the main interface between a field device

More information

File E Project December 11, 2013 REPORT DRIVERS FOR LIGHT-EMITTING DIODES ARRAYS MODULES AND CONTROLLERS

File E Project December 11, 2013 REPORT DRIVERS FOR LIGHT-EMITTING DIODES ARRAYS MODULES AND CONTROLLERS File E322469 Project 4786125262 December 11, 2013 REPORT On DRIVERS FOR LIGHT-EMITTING DIODES ARRAYS MODULES AND CONTROLLERS Lutron Electronics Co Inc Coopersburg, Pa Copyright 2013 UL LLC UL LLC authorizes

More information

OT 100/ /700 P5

OT 100/ /700 P5 OT 100/120 277/700 P5 OPTOTRONIC Outdoor Constant current LED drivers Areas of application _ Street and urban lighting _ Industry _ Suitable for luminaires of protection class I Product benefits _ High

More information

OPTEVA 828 LOBBY ATM FRONT LOAD PLAN VIEW FRONT ELEVATION SIDE ELEVATION

OPTEVA 828 LOBBY ATM FRONT LOAD PLAN VIEW FRONT ELEVATION SIDE ELEVATION L0 CALL -800--600 OPTEVA 88 LOBBY ATM FRONT LOAD WITH 0mm ( 6") CEN III AND CEN IV SAFE CONSULT WITH DIEBOLD INSTALLATION/SERVICE BRANCH FOR ADDITIONAL DETAILS AND INFORMATION. PLEASE SEE PLANNING AND

More information

Trusted 40 Channel Analogue Input FTA

Trusted 40 Channel Analogue Input FTA PD-T8830 Trusted Trusted 40 Channel Analogue Input FTA Product Overview The Trusted 40 Channel Analogue Input Field Termination Assembly (FTA) T8830 is designed to act as the main interface between a field

More information

FP-QUAD-510. Features. Power Requirement OPERATING INSTRUCTIONS. 4-Axis, Quadrature Input Module

FP-QUAD-510. Features. Power Requirement OPERATING INSTRUCTIONS. 4-Axis, Quadrature Input Module OPERATING INSTRUCTIONS FP-QUAD-510 4-Axis, Quadrature Input Module These operating instructions describe the installation, features, and characteristics of the FP-QUAD-510. For details on configuring and

More information

ODW-621. RS-232 Point-to-point applications

ODW-621. RS-232 Point-to-point applications Re-timing Data rate up to 250 kbit/s 9-position D-sub connector Redundant power supply inputs Status interface for fault indication Fibre link fault indication (Red) Design for harsh environments 40 to

More information

DLP200M 2 Relay Module for Heating and Cooling Plants

DLP200M 2 Relay Module for Heating and Cooling Plants Product Sheet TH6.24 Thermostat Type DLP200M DLP200M 2 Relay Module for Heating and Cooling Plants The DLP 200 M is a relay module for activation of loads (namely thermal actuators or circulators) in wireless

More information

MPCE Monitoring, Machine Test Signal. Guard Mode, Remote Reset. Eact Channel Select and Floating Blanking. Adjustable mounting brackets

MPCE Monitoring, Machine Test Signal. Guard Mode, Remote Reset. Eact Channel Select and Floating Blanking. Adjustable mounting brackets MicroSafe MCF4700 C US File No. LR90200 MicroSafe Flexible MCF4700-12, MCF4700-20, MCF4700-30 12 mm, 20 mm and 30 mm resolution versions Compact segmented light curtain 1.02 inch (26 mm) x 1.1 inch (28

More information

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15 > 8 channels for 2-wire HART transmitters > Inputs for Ex nl, Ex na and Nonincendive > Galvanic separation between inputs and system > Open-circuit and short-circuit monitoring for each field circuit >

More information

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A Deliveryprogramme Circuitbreak.3pselect.protection Partno. Articleno. 265777 NZMH4-VE1600 Product range Circuit-breaker Protective function Systems, cable, selectivity and generator protection Standard/Approval

More information

Trusted 40 Channel 120 Vac Digital Input FTA

Trusted 40 Channel 120 Vac Digital Input FTA PD-T8824 Trusted Trusted 40 Channel 120 Vac Digital Input FTA Product Overview The Trusted 40 Channel 120 Vac Digital Input Field Termination Assembly (FTA) T8824 is designed to act as the main interface

More information

SH2RE16A4. Output relay module. Benefits. Description

SH2RE16A4. Output relay module. Benefits. Description Output relay module Benefits Integrated system. Dupline is the brand name for Carlo Gavazzi s 2-wire bus system. Cost reduction. The use of a bus system is a proven way to reduce installation costs - especially

More information

Connecting cables for valves, round plug connectors Product range overview

Connecting cables for valves, round plug connectors Product range overview Connecting cables for valves, round plug connectors Product range overview Version Type code Connection technology (Electrical connection 2) Electrical connection 1: socket M8x1 4-pin NEBV-M8W4L Plug M8x1,

More information

Description Set value in neutral conductor is synchronous with set value Ir of main pole. R.m.s. value measurement and thermal memory CSA 100

Description Set value in neutral conductor is synchronous with set value Ir of main pole. R.m.s. value measurement and thermal memory CSA 100 DATASHEET - NZMN3-4-AE400 Circuit-breaker, 4p, 400A Part no. NZMN3-4-AE400 Catalog No. 265891 Similar to illustration EL-Nummer (Norway) 0004358857 Delivery program Product range Circuit-breaker Protective

More information

User Guide UD51. Second encoder small option module for Unidrive. Part Number: Issue Number: 5.

User Guide UD51. Second encoder small option module for Unidrive. Part Number: Issue Number: 5. EF User Guide UD51 Second encoder small option module for Unidrive Part Number: 0460-0084-05 Issue Number: 5 www.controltechniques.com Safety Information The option card and its associated drive are intended

More information

Quick-disconnect cables. Adjustable mounting brackets

Quick-disconnect cables. Adjustable mounting brackets MiniSafe File No. LR90200 Operation MiniSafe 1.0 inch (25.4 mm) resolution 100 foot (30.5 m) range Individual Beam Indicator lights covered by U.S. and international patents Compact size 2.25 x 1.8 inches

More information

HD-EXT2-C. HDMI over Shielded Twisted Pair Extender

HD-EXT2-C. HDMI over Shielded Twisted Pair Extender This product has been replaced by the HD-EXT4-C. The Crestron HDMI over Shielded Twisted Pair Extender (HD- EXT2-C) delivers professional-grade digital HD AV signal extension for use in a boardroom, classroom,

More information

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC Deliveryprogramme Contactorrelay,3N/O+1N/C,AC Partno. DILER-31(230V50HZ,240V60HZ) Articleno. 051768 CatalogNo. XTRM10A31F Product range DILER Mini-contactors Application Contactor relays Description with

More information

LONWORKS Fibre Optic Router

LONWORKS Fibre Optic Router LONWORKS Fiber Optic Router LRW-112 and LRW-112/PP LONWORKS to fibre optic link, multidrop and redundant ring applications The LRW-112 router offers an easy way to extend the distance between LONWORKS

More information

MB 204/MB 204-Ex. Multi-Barrier for PROFIBUS PA and FOUNDATION Fieldbus 10/ EN

MB 204/MB 204-Ex. Multi-Barrier for PROFIBUS PA and FOUNDATION Fieldbus 10/ EN Multi-Barrier for PROFIBUS PA and FOUNDAION Fieldbus 10/63-6.11 EN P R O F I PROCESS FIELD BUS B U S Intrinsically safe power supply of up to 31 stations on the bus, cascadable multi-barrier Intrinsically

More information

Modular pulse operated latching relay 16 A

Modular pulse operated latching relay 16 A 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 Modular pulse operated latc / 05 / 07 / 08 / 10 / 11 / 12 / 14 / 16 / 20 and 927 00 / 49 CONTENTS PAGES 1. Description,

More information

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A DATASHEET - NZMN3-VE630 Circuit-breaker, 3p, 630A Part no. NZMN3-VE630 Catalog No. 259133 EL-Nummer (Norway) 0004358791 Similar to illustration Delivery program Product range Circuit-breaker Protective

More information

Magnecraft Power Relays

Magnecraft Power Relays Description DPST-NO, 30 A; DPDT, 30 A (NO) / 3 A (NC) Description The series power relays offer a small package size and features Class F insulation for a maximum coil temperature of 55 C (3 F). These

More information

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control XT Family of Contactors Contactors and Starters Product Description The Eaton XT contactors and starters includes nonreversing and reversing contactors, overload relays and a variety of related accessories.

More information

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40 Characteristics Type of contactor LC- LC- LC- LC- LC-D & D09 D8 D2 D38 D40 D0 D9 LC-D0 DT20 & DT2 DT32 & DT40 Environment Rated insulation voltage (Ui) Conforming to IEC 947-4-, overvoltage category III,

More information

Fibre Optic Modem ODW-611

Fibre Optic Modem ODW-611 Fibre Optic Modem ODW-611 PROFIBUS DP to fibre optic link, point-to-point applications The ODW-611 is a fibre optic modem designed for point-to-point fibre optic connections between PROFI- BUS DP networks.

More information

SINAMICS G130 / G150. Line harmonics filter. Operating Instructions 05/2010 SINAMICS

SINAMICS G130 / G150. Line harmonics filter. Operating Instructions 05/2010 SINAMICS SINAMICS G130 / G150 Line harmonics filter Operating Instructions 05/2010 SINAMICS s Safety information 1 General 2 SINAMICS SINAMICS G130 / G150 Operating Instructions Mechanical installation 3 Electrical

More information

Wall-/Pipe-Mount Level Indicator

Wall-/Pipe-Mount Level Indicator Data Sheet SS/_4 Wall-/Pipe-Mount Level Indicator High visibility 5-digit LED display clear multi-functional indication Analog and 2-relay outputs as standard high, low, latch and rate alarms, plus isolated

More information