1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

Size: px
Start display at page:

Download "1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control"

Transcription

1 . Manual Motor Protectors Contents Description Relays and Timers Miniature Controls Contactors and Starters Thermal Overload Relays C440/XT Electronic Overload Relay Manual Motor Protectors Features and Benefits Standards and Certifications Product Identification Selection Product Selection Accessories Technical Data and Specifications Dimensions Combination Motor Controllers XT Electronic Manual Motor Protector Reference Data Page V5-T-3 V5-T-8 V5-T-35 V5-T-28 V5-T-4 V5-T-58 V5-T-58 V5-T-59 V5-T-60 V5-T-6 V5-T-64 V5-T-76 V5-T-85 V5-T-93 V5-T-26 V5-T-229 Manual Motor Protectors Product Description Eaton s new XT family of manual motor protectors (MMPs) features a pushbutton or rotary ON/OFF manual disconnect, Class 0 adjustable bimetallic overload relay and fixed magnetic short-circuit trip capability in one compact unit. Two frame sizes are available: Frame B (45 mm) for motors with FLA ratings up to 32A and Frame D (55 mm) covers motor FLA ratings up to 65A. Application Description The XTPB and XTPR MMPs can be used in the following applications. Motor Protective Circuit Breaker In many countries outside of the United States and Canada, especially Europe, the MMPs are tested and classified as thermalmagnetic circuit breakers for use in motor branch circuits. This can be an important consideration for all companies who export their equipment and machines internationally. Both the XTPB and XTPR conform to IEC/EN and have the CE Mark. Manual Motor Protectors The XTPB and XTPR MMPs are UL listed under UL 508 as manual motor protectors. They provide an economical solution for applications requiring simple manual starting and stopping of motors. When used as a manual starter, they are typically installed in an enclosure. Many enclosures are offered as accessories for the MMPs. Separate shortcircuit protective devices, such as circuit breakers or fuses, are wired ahead of the MMPs. The short-circuit protective device should be sized per the NEC and should not exceed 400% of the maximum FLA dial setting of the MMP. Group Motor Installations A group motor installation can be defined as more than one motor circuit protected by a single set of fuses or circuit breaker on a motor branch circuit. This eliminates the need for individual fuses or circuit breakers for each motor circuit. Substantial component cost savings, panel space savings and reduced wiring installation time can be achieved in group motor installations. The MMPs are tested and listed for group installation. If remote operation is required, a magnetic contactor can be wired in series with the MMP. Article of the NEC contains the rules and requirements for group motor installations. Refer to application note AP E for NEC requirement for group motor installation. Individual Branch Motor Applications A UL 508 Type E selfprotected manual combination starter/motor controller consists of a single device possessing four essential elements: disconnect, short circuit protection, motor controller, and motor overload protection. Some MMPs require use of a lineside adapter for this type of approval. When tested as an official combination by UL, this device takes the place of a fuse-starter or breakerstarter, XT Type E MMPs are self-protected, meaning they do not need additional short circuit protection of a fuse or breaker. Type E devices can also be used with a contactor or other types of UL approved controllers. If tested with a contactor, the combination motor controller becomes a Type F device. See Page V5-T-99 for XTFC Type F devices. Volume 5 Motor Control and Protection CA E April V5-T-57

2 . Features and Benefits ON/OFF rotary handle with lockout provision Visible trip indication Class 0 overload protection Phase loss sensitivity Ambient temperature compensation to IEC/EN 60947, VDE 0660 Fixed short-circuit trip 4 times maximum setting of overload FLA dial Type 2 coordination per IEC 947 Identification markers standard on starter faceplate Motor applications from 0.A to 65A Built-in heater and magnetic trip elements to protect the motor Standards and Certifications CE approved UL listed File No. E UL 508 group motor and Type E compliant IEC/EN CSA File , Class DIN VDE 0660 Part 00, Part 0 and Part 02 Adjustment dial for setting motor FLA DIN rail mount Terminal types available: Screw terminals Screw (line) and spring cage (load) terminals Spring cage terminals Accessories include: Front and side auxiliary contacts Trip indicating contacts Tamperproof cover for OLR dial Undervoltage release Shunt trip Through-the-door operators Enclosures Three-phase line side connecting links Line Side Adapters When to Use Them Note: Line side adapters are not required for non-us applications. Most countries outside of the US classify the MMP as a thermal magnetic circuit breaker. Group Installation Upstream SCPD required. Line Side Adapter (LSA) Not required Manual Motor Protector and Line Side Adapter Manual Motor Protectors Self-Protected Manual Combination Starters UL 508 Type E Self-Protected Manual Combination Starter Self-protected. No additional SCPD needed in branch circuit. Line Side Adapter (LSA) Required Line Side Adapter XTPAXLSA MMP XTPR BC Line Side Adapter XTPAXLSAD MMP XTPR DC Note: For Type 2 Coordination of MMCs, see Page V5-T-230. V5-T-58 Volume 5 Motor Control and Protection CA E April 203

3 . Product Identification Notes Basic Units XTPB pushbutton manual motor protectors (see Page V5-T-6) Rated operational current up to 25A Switching capacity 50 ka/45v Short-circuit release, adjustable 0.6 x l u Single-phasing sensitive 2 XTPR rotary manual motor protectors (see Page V5-T-62) Rated operational current up to 32A, 65A Switching capacity 50/50 ka/45v Short-circuit release, fixed setting to 4 x l u Overload release, adjustable 0.6 x l u Single-phasing sensitive With screws or spring-loaded terminals Mounting Accessories 3 Rotary handle mechanism (see Page V5-T-67) ON/OFF/tripped switch position indication Lockable door/cover interlock Extendable y plug fit extension shaft Handle latched in switch positions Optionally also without locking and door interlock function Insulated enclosures (see Page V5-T-7) Surface mounting, enclosures, IP40, IP55 and IP40 and IP55 front flush mounting enclosure Mounting/wiring (see Page V5-T-67) Component adapter for busbar mounting Three-phase commoning link for side-by-side-mounting Mounting kits for rapid mounting of direct-on-line, reversing and stardelta starters Add-On Functions 4 Voltage releases (see Page V5-T-66) Undervoltage release Shunt releases With screws or spring-loaded terminals 5 Standard auxiliary contacts (see Page V5-T-64) ON/OFF indication Differential fault indication overload/ short-circuit release ON/OFF for (high capacity) contact module ON/OFF for starter combination With early-make contacts With screws or spring-loaded terminals 6 Current limiter (see Page V5-T-66) Increases the switching capacity of the 0 25A manual motor protectors to 00 ka/440v Can be used for individual group protection Volume 5 Motor Control and Protection CA E April V5-T-59

4 . Selection XT Manual Motor Protectors XT PR 02 B C Designation XT = XT IEC power control PB PR PM PT Type = Manual motor protector pushbutton = Manual motor protector rotary = Manual motor protector magnetic only = Manual transformer protector (high mag.) Frame B P6 = 0.6A P25 = 0.25A P40 = 0.40A P63 = 0.63A 00 = A P6 =.6A 2P5 = 2.5A 004 = 4A 6P3 = 6.3A 00 = 0A 02 = 2A 06 = 6A 020 = 20A 025 = 25A 032 = 32A Current Ratings Frame D 06 = 6A 025 = 25A 032 = 32A 040 = 40A 050 = 50A 058 = 58A 063 = 63A Frame Size B = 45 mm D = 55 mm Trip Class C =Class 0 Blank = Magnetic only (no thermal trip) V5-T-60 Volume 5 Motor Control and Protection CA E April 203

5 . Product Selection Product Selection for Manual Motor Starter Applications When ordering, specify catalog numbers according to the following stipulations: XT manual motor protectors are selected based on the overload current range required for a given motor. This current range is determined from the motor full load ampere rating and motor service factor usually found on the motor nameplate. Frame B For motors with service factors less than.5, multiply the motor FLA by 0.90 to select appropriate MMP. Example: For motor having FLA of 6.4A and service factor of.0 (6.4A x 0.90 = 5.76A) select catalog number XTPB6P3B0. See Application Note AP E. For motor with service factor of.5 or greater, use motor nameplate full load amperes to select the appropriate MMP. Example: For motor having FLA of A and service factor of.5, select catalog number XTPR02BC. XTPB Pushbutton Manual Motor Protectors Global and North American Ratings Frame B Type and Type 2 Coordination Motor Protective Device with Thermal and Magnetic Trip Rated Uninterrupted Current I u = I e (Amps) FLA Adjustment Range/ Overload Release I r (Amps) Short Circuit Release I rm (Amps) Maximum Motor Ratings Maximum kw Rating AC-3 P (kw) Three-Phase V V 440V 500V Notes Single-phasing sensitivity to IEC/EN , VDE 0660 Part 02. Can be snap-fit to IEC/EN 6075 top-hat (DIN) with 7.5 or 5 mm height. Service Factor (SF) Setting I r of current scale in dependence of load factor: SF =.5 I r = x I n mot SF = I r = 0.9 x I n mot For manual motor protective circuit breaker switching capacity, see Page V5-T-8. Select manual motor protectors by full load amperes. Maximum motor ratings (kw, hp) are for reference only. 2 In this range, calculate motor rating according to rated current. Specified values to NEC 430.6(A)(). Maximum hp Rating P (hp) UL 508/CSA C22.2 No. 4 Three-Phase V 200V 240V 480V 600V Screw Terminal XTPBP6BC XTPBP25BC XTPBP40BC XTPBP63BC /2 XTPB00BC /4 3/4 XTPBP6BC /2 /2 -/2 XTPB2P5BC /4 3/4 2 3 XTPB004BC /2 3 5 XTPB6P3BC /2 0 XTPB00BC /2 0 XTPB02BC XTPB06BC XTPB020BC / XTPB025BC Volume 5 Motor Control and Protection CA E April V5-T-6

6 . Frame B Frame D XTPR Rotary Manual Motor Protectors with Screw Terminals Global Ratings and North American Ratings Frame B Type and Type 2 Coordination Motor Protective Device with Thermal and Magnetic Trip Rated Uninterrupted Current I u = I e (Amps) FLA Adjustment Range/ Overload Release I r (Amps) Short Circuit Release I rm (Amps) Maximum Motor Ratings Maximum kw Rating AC-3 P (kw) Three-Phase V V 440V 500V XTPR Rotary Manual Motor Protectors with Screw Terminals Global Ratings and North American Ratings Frame D Type and Type 2 Coordination Motor Protective Device with Thermal and Magnetic Trip Notes Single-phasing sensitivity to IEC/EN , VDE 0660 Part 02. Can be snap-fit to IEC/EN 6075 top-hat (DIN) with 7.5 or 5 mm height. Service Factor (SF) Setting I r of current scale in dependence of load factor: SF =.5 I r = x I n mot SF = I r = 0.9 x I n mot For manual motor protective circuit breaker switching capacity, see Page V5-T-8. Select manual motor protectors by full load amperes. Maximum motor ratings (kw, hp) are for reference only. 2 In this range, calculate motor rating according to rated current. Specified values to NEC 430.6(A)(). Maximum hp Rating P (hp) UL 508/CSA C22.2 No. 4 Three-Phase V 200V 240V 480V 600V Screw Terminal XTPRP6BC XTPRP25BC XTPRP40BC XTPRP63BC XTPR00BC /4 3/4 XTPRP6BC /2 /2 -/2 XTPR2P5BC /4 3/4 2 3 XTPR004BC /2 3 5 XTPR6P3BC /2 0 XTPR00BC /2 0 XTPR02BC XTPR06BC XTPR020BC / XTPR025BC / XTPR032BC Rated Uninterrupted Current I u = I e (Amps) FLA Adjustment Range/ Overload Release I r (Amps) Short Circuit Release I rm (Amps) Maximum Motor Ratings Maximum kw Rating AC-3 P (kw) Three-Phase V V 440V 500V Maximum hp Rating P (hp) UL 508/CSA C22.2 No. 4 Three-Phase V 200V 240V 480V 600V Screw Terminal XTPR06DC /2 7-/ XTPR025DC XTPR032DC XTPR040DC XTPR050DC XTPR058DC XTPR063DC V5-T-62 Volume 5 Motor Control and Protection CA E April 203

7 . Frame B Frame D XTPR Manual Self-Protected Motor Starters North American Ratings, UL 508 Type E Frame B Motor Protective Device with Thermal and Magnetic Trip Rated Uninterrupted Current I u (Amps) FLA Adjustment Range/ Overload Release I r (Amps) Short Circuit Release I rm (Amps) Maximum Motor Ratings 2 Maximum hp Rating P (hp) Three-Phase 200V 240V 480V/ 277V Rated Short-Circuit Breaking Capacity (ka) Line Side Adapter XTPR Manual Self-Protected Motor Starters North American Ratings, UL 508 Type E Frame D Motor Protective Device with Thermal and Magnetic Trip 600V/ 247V Manual Motor Protector Screw Terminal /2 / XTPAXLSA XTPRP6BC /2 / XTPAXLSA XTPRP25BC /2 / XTPAXLSA XTPRP40BC /2 / XTPAXLSA XTPRP63BC /2 / XTPAXLSA XTPR00BC /4 3/ XTPAXLSA XTPRP6BC /2 /2 -/ XTPAXLSA XTPR2P5BC / XTPAXLSA XTPR004BC / XTPAXLSA XTPR6P3BC / XTPAXLSA XTPR00BC /2 65 XTPAXLSA XTPR02BC XTPAXLSA XTPR06BC XTPAXLSA XTPR020BC /2 5 8 XTPAXLSA XTPR025BC / XTPAXLSA XTPR032BC Rated Uninterrupted Current I u (Amps) FLA Adjustment Range/ Overload Release I r (Amps) Short Circuit Release I rm (Amps) Maximum Motor Ratings 2 Maximum hp Rating P (hp) Three-Phase 200V 240V 480V/ 277V 600V/ 247V Notes A UL 508 Type E self-protected manual combination starter (XTPR) consists of a manual motor protector (XTPR) and a UL Listed line side adapter (for example, XTPAXLSA). The Type E self-protected manual combination starter alone is a legitimate short-circuit protective device and disconnect means for the downstream motor, while the contactor has been added to provide remote operation of the motor circuit. Conductor size for XTPAXLSA is 4 6 AWG, XTPAXLSAD is 8 AWG /0. UL 508 Type E starters are assembled from a standard XTPR and a special incoming terminal line side adapter (XTPAXLSA or XTPAXLSAD). 2 Select manual motor protectors by full load amperes. Maximum motor ratings (kw, hp) are for reference only. 3 In this range, calculate motor rating according to rated current. Specified values to NEC 430.6(A)(). 480/ 277V 600/ 347V Rated Short-Circuit Breaking Capacity (ka) 240V 480/ 277V 600/ 347V Line Side Adapter Manual Motor Protector Screw Terminal XTPAXLSAD XTPR06DC /2 7-/ XTPAXLSAD XTPR025DC XTPAXLSAD XTPR032DC XTPAXLSAD XTPR040DC XTPAXLSAD XTPR050DC XTPAXLSAD XTPR058DC XTPAXLSAD XTPR063DC Volume 5 Motor Control and Protection CA E April V5-T-63

8 . Accessories Auxiliary Contacts XTPAXSA_ XTPAXFA Side-Mount Auxiliary Contacts Contact Configuration Contact Sequence Can be fitted on the right side of manual motor protectors (XTPB, XTPR, XTPM) and manual transformer protectors (XTPT) and can be combined with XTPAXSATR_ and XTPAXFA_ trip indicating auxiliary contact. Front-Mount Auxiliary Contacts Contact Configuration Contact Sequence Can be fitted to manual motor protectors (XTPB, XTPR, XTPM) and manual transformer protectors (XTPT). 45 mm (XTPR B and XTPB) or 55 mm (XTPR D) widths of manual motor protectors remain unchanged. Note Orders must be placed in multiples of package quantity listed. Pkg. Qty. Screw Terminal NO-NC XTPAXSA L L2 L3 XTPAXSA.4.22 NO-2NC XTPAXSA2 L L2 L3 XTPAXSA NO-NC XTPAXSA2 L L2 L3 XTPAXSA Pkg. Qty. Screw Terminal NO-NC XTPAXFA L L2 L3 XTPAXFA V5-T-64 Volume 5 Motor Control and Protection CA E April 203

9 . XTPAXSATR_ XTPBXFAEM20 XTPAXFAEM20 Side-Mount Trip Indicating Auxiliary Contacts Contact Configuration Contact Sequence Can be fitted on the right side of manual motor protectors. Can be combined with standard auxiliary contacts. Trip indication: A. General trip indication (overload) B. Short-circuit trip. Local short-circuit indication by red indicator, manually resettable. Early-Make Front-Mount Auxiliary Contacts For use with XTPB_, Frame B XTPR and XTPT. Can be fitted to the front of a manual motor protector. 45 mm width of manual motor protector remains unchanged. For early energization of undervoltage release, for example, in emergency-stop circuits to EN Notes Orders must be placed in multiples of package quantity listed. 2 Not for use with rotary handle mechanism. Pkg. Qty. For Use with 2 x NO + 2 XTPB, XTPR, XTPM, XTPT 2 x NC + 2 XTPB, XTPR, XTPM, XTPT Contact Configuration On/Off LL2L3 + > Trip + LL2L3 + > On/Off LL2L3 + > Trip + LL2L3 + > Contact Sequence Pkg. Qty. For Use with XTPAXSATR20 XTPAXSATR02 2NO XTPB XTPBXFAEM NO 2 XTPR, XTPM, XTPT XTPAXFAEM20 2 Volume 5 Motor Control and Protection CA E April V5-T-65

10 . Additional Accessories XTPAXSR_ Contact Sequence C C2 XTPAXCL Shunt Release Pkg. Qty. Can be used to trip the manual motor protector from a remote location. Can be fitted on the left side of manual motor protectors. Cannot be combined with the XTPAXUVR. DC: Intermittent operation 5 sec. Current Limiter 2 Screw Terminal 2 XTPAXSR24V50H 2 XTPAXSR48V50H 2 XTPAXSR0V50H 2 XTPAXSR20V60H 2 XTPAXSR208V60H 2 XTPAXSR220V50H 2 XTPAXSR230V50H 2 XTPAXSR240V50H 2 XTPAXSR240V60H 2 XTPAXSR380V50H 2 XTPAXSR400V50H 2 XTPAXSR45V50H 2 XTPAXSR440V60H 2 XTPAXSR480V60H 2 XTPAXSR24VDC 2 XTPAXSR48VDC 2 XTPAXSR60VDC 2 XTPAXSR0VDC 2 XTPAXSR25VDC 2 XTPAXSR220VDC 2 XTPAXSR250VDC Description To enhance the switching capacity of non-inherently safe 0 25A manual motor protectors to 50 ka/440v Contact Sequence XTPAXUVR_ Contact Sequence The XTPAXCL enhances the switching capacity of the XT manual motor protectors. It can be used with the XTPB, XTPR BC, XTPR DC for individual or group protections. The rated uninterrupted current is 63A for IEC and 25A for UL/CSA. It can be mounted next to or behind the manual motor protector. See Page V5-T-8 for ratings when using the current limiter. Undervoltage Release Pkg. Qty. Notes Orders must be placed in multiples of package quantity listed. 2 Max. rated operation voltage Ue = 690V, rated uninterrupted current I u = 63A. Can be used for individual and group protection. For group protection and in combination with the XTPR D order additional XTPAXIT incoming terminal if required. Mounting next to or behind the manual motor protector. 6 63A XTPR D: 00 ka/400v, 0 ka/690v. L T D U D2 Pkg. Qty. Screw Terminal 2 XTPAXUVR24V50H 2 XTPAXUVR24V60H 2 XTPAXUVR48V50H 2 XTPAXUVR60V50H 2 XTPAXUVR0V50H 2 XTPAXUVR20V60H 2 XTPAXUVR208V60H 2 XTPAXUVR220V50H 2 XTPAXUVR230V50H 2 XTPAXUVR240V50H 2 XTPAXUVR240V60H 2 XTPAXUVR380V50H 2 XTPAXUVR400V50H 2 XTPAXUVR45V50H 2 XTPAXUVR440V60H 2 XTPAXUVR480V60H 2 XTPAXUVR600V60H Can be used to trip the manual motor protector from a remote location. Can be fitted on left side manual motor protectors. Cannot be combined with XTPAXSR. When combined with a circuit breaker, it can be used as emergency-stop device to IEC/EN XTPAXCL V5-T-66 Volume 5 Motor Control and Protection CA E April 203

11 . XTPAXRHM_ XTPAXRHMSFT XTPAXSW IP65 Rotary Handle Mechanism 234 Description Sealing Facility Three-Phase Commoning Links 8 Enclosure Rating Pkg. Qty. 5 For parallel power feed to several manual motor protectors on terminals, 3 and 5. Complete Kits Includes Handle, Shaft and Required Hardware Rotary handle mechanism black 6 IP65 XTPAXRHMB Rotary handle mechanism red/yellow 7 NEMA 2 UL/CSA 4X XTPAXRHMRY Rotary handle mechanism black rotated 90 from vertical 6 XTPAXRHM90B Rotary handle mechanism red/yellow rotated 90 from XTPAXRHM90RY vertical 7 Separate Parts Shaft only includes shaft to mount to XTPR, 75 mm length 0 XTPAXRHMSFT Description To prevent tampering with the overload release and the test function. It can be sealed using industry standard sealing wire. For use with XTPR manual motor protectors. For Use with MMP with no side-mounted auxiliaries or voltage releases Each MMP with one auxiliary contact or trip-indicating auxiliary contact fitted on the right Each MMP with an auxiliary contact and trip-indicating auxiliary contact mounted on the right or a voltage release mounted on the left. Qty. MMP MMP Frame Size Pkg. Qty. 5 5 XTPAXSW Pkg. Qty. 5 2 B 0 XTPAXCLKA2 D XTPAXCLKA2D 3 B 0 XTPAXCLKA3 D XTPAXCLKA3D 4 B 0 XTPAXCLKA4 D XTPAXCLKA4D 5 B 0 XTPAXCLKA5 2 B 0 XTPAXCLKB2 D XTPAXCLKB2D 3 B 0 XTPAXCLKB3 D XTPAXCLKB3D 4 B 0 XTPAXCLKB4 D XTPAXCLKB4D 5 B 0 XTPAXCLKB5 2 B 0 XTPAXCLKC2 4 D XTPAXCLKC4D Notes Plug-in connection shafts, XTPAXRHMSFT_ can be cut to desired length for mounting depths of mm. Carrier with extension shaft included. 2 With ON/OFF switch position and + (tripped), lockable with 3 padlocks, 4 8 mm hasp. Can be locked in the OFF position, if required. 3 Rotary handle mechanisms ship with door interlock disabled. See instruction publication with product for how to enable door interlock. 4 Not for use with XTPAXFAEM20 early-make front-mount auxiliary contact. 5 Orders must be placed in multiples of package quantity listed. 6 For use on main switches to IEC/EN For use on main switches with emergency-stop function to IEC/EN Protected against accidental contact. Frame B short-circuit proof Ue = 690V, I u = 63A. Frame B links can be combined by rotating mounting. Volume 5 Motor Control and Protection CA E April V5-T-67

12 . XTPAXUTS XTPAXIT XTPAXLSA XTPAXLSAD Combination Connection Kits XTPAXTPCB XTPAXTPC_ Shroud for Unused Terminals of Three-Phase Commoning Links Pkg. For Use with Description Qty. Frame B XTPR Incoming Terminals for Three-Phase Commoning Link 2 For Use with Line-Side Adapter 3 Non-Reversing Starters To cover unused terminals on three-phase commoning link. Protected against direct contact. Pkg. Qty. Frame B XTPR, XTPB 5 XTPAXIT For Use with Frame B XTPR to create a UL 508 Type E/F manual combination starter Frame D XTPR to create a UL 508 Type E/F manual combination starter For Use with Pkg. Qty. 5 XTPAXLSA XTPAXLSAD 4 Description/Comprised of 20 XTPAXUTS Notes Orders must be placed in multiples of package quantity listed. 2 For three-phase commoning link, protected against accidental contact, Ue = 690V, I u = 63A; For conductor cross-sections: mm2 stranded; mm2 flexible with ferrules, AWG XTPAXLSA is for three-phase commoning link, finger and back-of-hand proof, Ue = 690V, I u = 60A for conductor cross sections: mm2 stranded, mm2 flexible with ferrule, AWG XTPAXLSAD cannot be combined with three-phase commoning links. Conductor size 8 AWG /0. Std. Pack XTPR B + XTCE B Mechanical connection element for XTPR B and contactor XTPAXTPCB XTPR B + XTCE C XTPR D + XTCE D Main current wiring between XTPR B and contactor in toolless plug connection Use contactor auxiliary switch XTCEXFAT_. Control cable guidance: max. six cables up to 2.5 mm 2 external diameter or four cables up to 3.5 mm 2 external diameter. DIN rail adapter plate Main current wiring between XTPR and contactor DIN rail adapter plate Main current wiring between XTPR and contactor XTPAXTPCC XTPAXTPCD V5-T-68 Volume 5 Motor Control and Protection CA E April 203

13 . XTPAXTPCRB XTPAXTPCRC Reversing Starters For Use with Description/Comprised of Note Orders must be placed in multiples of package quantity listed. Std. Pack XTPR B + XTCE B0_ Mechanical connection element for XTPR B and contactor XTPAXTPCRB Reversing starter main current wiring in toolless plug connection Control cables for electrical interlocking in toolless plug connection: KM: A K2M: 2 KM: 2 K2M: A KM: A2 K2M: A2 Cable guidance Use contactor auxiliary switch XTCEXFAT_. Control cable guidance: max. six cables up to 2.5 mm 2 external diameter or four cables up to 3.5 mm 2 external diameter. XTPR B + XTCE C DIN rail adapter plate XTPAXTPCRC Reversing starter main current wiring Volume 5 Motor Control and Protection CA E April V5-T-69

14 . XTPAXECM_ XTPAXTPCPB XTPAXTPCPD Electrical Connection Module For Use with DIN Rail Adapter Plates Note Description/Comprised of Orders must be placed in multiples of package quantity listed. Std. Pack XTPR B + XTCE C Main current wiring between XTPR B and contactor 5 XTPAXECMC XTPR D + XTCE D Main current wiring between XTPR D and contactor 5 XTPAXECMD For Use with XTPAXTPCB XTPAXTPCRB XTPAXECMD XTPR D + XTCE C XTPR D + XTCE D Description/Comprised of Std. Pack 45 mm wide adapter plate with one DIN rail 4 XTPAXTPCPB Connection element for side-by-side positioning of further plates 55 mm wide adapter plate with two DIN rails 4 XTPAXTPCPD Connection cams for further plates For use with reversing and star-delta starters V5-T-70 Volume 5 Motor Control and Protection CA E April 203

15 . Pushbutton MMP Enclosures Insulated Enclosures for Surface Mounting of XTPB Pushbutton Motor-Protective Circuit Breakers Global Usage Degree of Protection IP40 NEMA IP65 NEMA 3R, 4X, 2, 3 IP65 NEMA 3R, 4X, 2, 3 IP65 NEMA 3R, 4X, 2, 3 IP65 NEMA 3R, 4X, 2, 3 IP65 NEMA 3R, 4X, 2, 3 For Use with Description XTPB MMP only or with: XTPAXFA_, XTPBXFAEM20, XTPAXSA_, XTPAXUVR_, XTPAXSR_ XTPB MMP only or with: XTPAXFA_, XTPAXUVR_, XTPAXSR_, XTPAXCL Insulated Enclosures for Surface Mounting of XTPB Pushbutton Manual Motor Protectors North American Usage 23 Degree of Protection IP4 NEMA IP65 NEMA 3R, 4X, 2, 3 IP65 NEMA 3R, 4X, 2, 3 IP65 NEMA 3R, 4X, 2, 3 IP65 NEMA 3R, 4X, 2, 3 IP65 NEMA 3R, 4X, 2, 3 XTPB MMP only or with: XTPAXFA_, XTPBXFAEM20, XTPAXUVR_, XTPAXSR_, XTPAXCL Notes Integrated terminal for PE(N) connection, two M25 cable entry knockouts at top and at bottom. 2 Built-in terminal for PE(N). 3 North American enclosures come with conduit adapters for use with /2 in NPT. XTPBXENCS40 With actuation membrane. Lockable in OFF position. Lockable in OFF position in combination with XTPBXFAEM20 early-make front-mount auxiliary contact With emergency-stop (e-stop) pushbutton actuator, red-yellow With emergency-stop (e-stop) pushbutton actuator, red-yellow key release XTPBXENCS65 XTPBXENCSLO65 XTPBXENCSLE65 XTPBXENCSES65 XTPBXENCSEK65 For Use with Description XTPB MMP only or with: XTPAXFA_, XTPBXFAEM20, XTPAXSA_, XTPAXUVR_, XTPAXSR_ XTPB MMP only or with: XTPAXFA_, XTPAXUVR_, XTPAXSR_, XTPAXCL XTPB MMP only or with: XTPAXFA_, XTPBXFAEM20, XTPAXUVR_, XTPAXSR_, XTPAXCL XTPBXENAS4 With actuating diaphragm Lockable in OFF position Lockable in OFF position in combination with XTPBXFAEM20 early-make front-mount auxiliary contact With emergency-stop (e-stop) pushbutton actuator, red-yellow With emergency-stop (e-stop) pushbutton actuator, red-yellow key release XTPBXENAS65 XTPBXENASLO65 XTPBXENASLE65 XTPBXENASES65 XTPBXENASEK65 Volume 5 Motor Control and Protection CA E April V5-T-7

16 . Insulated Enclosures for Surface Mounting of XTPB Pushbutton Manual Motor Protectors North American Usage Degree of Protection Front IP40 NEMA Front IP65 NEMA 3R, 4X, 2, 3 Front IP65 NEMA 3R, 4X, 2, 3 Front IP65 NEMA 3R, 4X, 2, 3 Front IP65 NEMA 3R, 4X, 2, 3 Front IP65 NEMA 3R, 4X, 2, 3 Note Integrated terminal for PE(N) connection. For Use with Description XTPB MMP only or with: XTPAXFA_, XTPBXFAEM20, XTPAXSA_, XTPAXUVR_, XTPAXSR_ XTPB MMP only or with: XTPAXFA_, XTPAXUVR_, XTPAXSR_, XTPAXCL XTPB MMP only or with: XTPAXFA_, XTPBXFAEM20, XTPAXUVR_, XTPAXSR_, XTPAXCL XTPBXENCF40 With actuating diaphragm Lockable in OFF position Lockable in OFF position in combination with XTPBXFAEM20 early-make front-mount auxiliary contact With emergency-stop (e-stop) pushbutton actuator, red-yellow With emergency-stop (e-stop) pushbutton actuator, red-yellow key release XTPBXENCF55 XTPBXENCFLO55 XTPBXENCFLE55 XTPBXENCFES55 XTPBXENCFEK55 V5-T-72 Volume 5 Motor Control and Protection CA E April 203

17 . Rotary MMP Enclosures Insulated Enclosures for Surface Mounting of Frame B (0. 32A) XTPR Motor-Protective Circuit Breakers Global Usage Degree of Protection IP4 with vertical mounting For Use with Description Frame B XTPR only or with: XTPAXFA_, XTPAXSA_, XTPAXSATR_, XTPAXUVR_, XTPAXSR_, XTPAXCL Cover with aperture dimensioned to accommodate front of MMP. IP40, when mounted turned through 90 to left/right Insulated Enclosures for Surface Mounting of Frame B (0. 32A) XTPR Rotary Manual Motor Protectors North American Usage 3 Insulated Enclosures for Surface Mounting of Frame B XTPR (0. 32A) Rotary Motor-Protective Circuit Breakers with XTPAXFAEM20 Early-Make Front-Mount Auxiliary Contact Global Usage Notes M25 metric cable entry knock-out, top and bottom. Cable push-through membrane, top and bottom, in the back plate and as a control line entry. Includes N and PE terminals. 2 Integrated terminal for PE(N) connection, two M25 cable entry knockouts at the top and bottom. 3 Built-in N and PE terminal, lower part without knockouts. XTPAXENCS4 IP65 With black/grey rotary handle XTPAXENCS65B IP65 IP40 IP55 IP55 Degree of Protection IP55 NEMA, 2, 3R Degree of Protection IP65 IP65 IP55 IP55 Frame B XTPR only or with: XTPAXSA_, XTPAXUVR_, XTPAXSR_, XTPAXCL Frame B XTPR only or with: XTPAXFA_, XTPAXSA_, XTPAXUVR_, XTPAXSR_, XTPAXCL With red/yellow rotary handle for use as emergency-stop switches to IEC/EN XTPAXENCS65RY Cover with aperture dimensioned to accommodate front of MMP XTPAXENCS40 2 With black/gray rotary handle XTPAXENCS55B 2 With red/yellow rotary handle for use as emergency-stop switches to IEC/EN XTPAXENCS55RY 2 For Use with Description Frame B XTPR only or with: XTPAXSA_ and XTPAXFA_, XTPAXUVR_ and XTPAXFA_, XTPAXSR_ and XTPAXFA_, XTPAXCL With black/gray rotary handle With red/yellow rotary handle for use as emergency-stop switch to VDE 03 XTPAXENAS55B XTPAXENAS55RY For Use with Description Frame B XTPR and XTPAXFAEM20 only or with: XTPAXFA_, XTPAXSA_, XTPAXSATR_, XTPAXUVR_, XTPAXSR_, XTPAXCL Frame B XTPR and XTPAXFAEM20 only or with: XTPAXFA_, XTPAXUVR_, XTPAXSR_, XTPAXCL With black/gray rotary handle With red/yellow rotary handle for use as emergency-stop switches to IEC/EN With black/gray rotary handle With red/yellow rotary handle for use as emergency-stop switches to IEC/EN XTPAXENCSEM65B XTPAXENCSEM65RY XTPAXENCSEM55B XTPAXENCSEM55RY Volume 5 Motor Control and Protection CA E April V5-T-73

18 . Insulated Enclosures for Surface Mounting of Frame B XTPR (0. 32A) Rotary Manual Motor Protectors with XTPAXFAEM20 Early-Make Front-Mount Auxiliary Contact North American Usage Degree of Protection IP55 NEMA, 2, 3R For Use with Description Frame B XTPR only or with: XTPAXSA_, XTPAXUVR_, XTPAXCL Insulated Enclosures for Flush Mounting of Frame B (0. 32A) XTPR Rotary Manual Motor Protectors Global Usage 2 Degree of Protection Front IP40 Front IP55 Insulated Enclosures for Surface Mounting of Frame D (0 65A) Rotary Motor-Protective Circuit Breakers Degree of Protection IP65 NEMA, 2, 3R, 4X IP65 NEMA, 2, 3R, 4X Notes Built-in N and PE terminal, lower part without knockouts. 2 Integrated terminal for PE(N) connection. With black/grey rotary handle With red/yellow rotary handle for use as emergency-stop switch to VDE 03 XTPAXENASEM55B XTPAXENASEM55RY For Use with Description Frame B XTPR only or with: XTPAXSA_, XTPAXUVR_, XTPAXSR_, XTPAXCL Frame B XTPR only or with: XTPAXSA_, XTPAXUVR_, XTPAXSR_, XTPAXFA_, XTPAXCL Cover with aperture dimensioned to accommodate front of MMP With black/gray rotary handle With red/yellow rotary handle for use as emergency-stop switches to IEC/EN XTPAXENCF40 XTPAXENCF55B XTPAXENCF55RY For Use with Description Frame D XTPR only or with: XTPAXFA_, XTPAXFAEM20, XTPAXSA_, XTPAXSATR_, XTPAXUVR_, XTPAXSR_, XTPAXCL With black/gray rotary handle With red/yellow rotary handle for use as emergency-stop switches to IEC/EN XTPAXENCSD65B XTPAXENCSD65RY V5-T-74 Volume 5 Motor Control and Protection CA E April 203

19 . MMP Enclosure Accessories XTPAXPL_ XTPAXNT XTPAXIL_ XTPR Manual Motor Protector Enclosure Padlock Attachment For Use with Description XTPAXENCS65B, XTPAXENCS65RY, XTPAXENCSEM65B, XTPAXENCSEM65RY, XTPAXENCS55B, XTPAXENCS55RY, XTPAXENCSEM55B, XTPAXENCSEM55RY Neutral Terminal for Use with XTPB and Frame B XTPR Flush-Mount Enclosures For Use with Description Indicating Lights with Neon Bulb Description Color Indicating Light For use with XTPR and XTPB enclosures. Lights do not carry individual IP or NEMA rating. All enclosure ratings remain valid when using indicating lights. Notes Orders must be placed in multiples of package quantity listed. 2 Lockable in the 0-position of the XTPR manual motor protector. 3 Lockable in the OFF position of the Frame B XTPR manual motor protector. Padlocking feature. Up to three padlocks with 3 6 mm hasp thickness. For use as main switch to IEC/EN Pkg. Qty. 3 XTPAXPL 2 XTPAXENCSD65B, XTPAXENCSD65RY XTPAXPL2 2 XTPAXENCF55B, XTPAXENCF55RY 3 XTPAXPL3 3 XTPBXENCF40, XTPBXENCF55, XTPAXENCF40, XTPAXENCF55B, XTPAXENCF55RY Pkg. Qty. For connection of a fifth conductor 20 XTPAXNT Pkg. Qty. White 0 230V 0 XTPAXILWB V 0 XTPAXILWN V 0 XTPAXILWC Green 0 230V 0 XTPAXILGB V 0 XTPAXILGN V 0 XTPAXILGC Red 0 230V 0 XTPAXILRB V 0 XTPAXILRN Volume 5 Motor Control and Protection CA E April V5-T-75

20 . Technical Data and Specifications XT Manual Motor Protectors Description General XTPBP6B XTPB025B Standards IEC/EN 60947, VDE 0660, UL 508, CSA C22.2 No. 4 Note Damp heat, constant, to IEC ; damp heat, cyclic, to IEC XTPRP6B XTPR032B IEC/EN 60947, VDE 0660, UL 508, CSA C22.2 No. 4 XTPR06D XTPR063D IEC/EN 60947, VDE 0660, UL 508, CSA C22.2 No. 4 Climatic proofing Ambient temperature, C Storage 25/80 25/80 25/70 Open 25/55 25/55 25/55 Enclosed 25/40 25/40 25/40 Mounting position Direction of incoming supply As required As required As required Degree of protection Device IP20 IP20 IP20 Terminals IP00 IP00 IP00 Protection against direct contact Finger and back-of-hand proof Finger and back-of-hand proof Shock resistance half-sinusoidal shock ms to IEC (g) Altitude (m), maximum Terminal capacity Solid (mm 2 ) x ( 6) 2 x ( 6) Flexible with ferrule to DIN 46228, (mm 2 ) x ( 6) 2 x ( 6) x ( 6) 2 x ( 6) x ( 6) 2 x ( 6) Solid or stranded (AWG) Terminal screw tightening torque Main cable, Nm.7. 3 Main cable, lb-in Control circuit cable, Nm Control circuit cable, lb-in Main Contacts Rated impulse withstand voltage (U imp ), Vac Overvoltage category/pollution degree III/3 III/3 III/3 Rated operational voltage (U e ), Vac Rated uninterrupted current = rated operational current (I u = I e ) in amperes 25 or current setting of the overcurrent release 25 or current setting of the overcurrent release Finger and back-of-hand proof x ( 50) 2 x ( 35) x ( 35) 2 x ( 35) 25 or current setting of the overcurrent release Rated frequency, Hz Current heat loss (three-pole at operating temperature), W Lifespan, mechanical (ops) 50,000 00,000 30,000 Lifespan, electrical (AC-3 at 400V) (ops) 50,000 00,000 30,000 Maximum operating frequency, operations/hr Short-circuit rating AC See Page V5-T-8 See Page V5-T-8 See Page V5-T-8 DC (ka) (up to XTPR06B) (XTPR020B XTPR032B) Motor switching capacity AC-3 (up to 690V) in amperes DC-5 (up to 250V) in amperes (3 contacts in series) 63 (3 contacts in series) V5-T-76 Volume 5 Motor Control and Protection CA E April 203

21 . XT Manual Motor Protectors, continued Description XTPBP6B XTPB025B XTPRP6B XTPR032B XTPR06D XTPR063D Releases Overload release setting range (x I u ) Fixed short-circuit release (x I u ) Short-circuit release tolerance ± 20% ± 20% ± 20% Phase-failure sensitivity IEC/EN , VDE 0660 Part 02 Temperature compensation IEC/EN , VDE 0660 Part 02 to IEC/EN 60947, VDE 0660, C 5/40 5/40 5/40 operating range, C 25/55 25/55 25/55 Temperature compensation residual error for T >20 C, %/K <0.25 <0.25 <0.25 IEC/EN , VDE 0660 Part 02 Auxiliary Contacts Description XTPAXSA XTPAXFA XTPA(B)XFAEM XTPAXSATR Rated impulse withstand voltage, U imp (Vac) Overvoltage category/pollution degree III/3 III/3 III/3 III/3 Rated operational voltage U e (Vac) U e (Vdc) Safe isolation to VDE 006 Part 0 and Part 0/A between auxiliary contacts and main contacts (Vac) Rated operational current AC V, I e (A) V, I e (A) V, I e (A) DC-3 L/R <00 ms 24 V, I e (A) V, I e (A) V, I e (A) 220 V, I e (A) Lifespan Mechanical, operations (x 0 6 ) Electrical, operations (x 0 6 ) Contact reliability (at U e = 24 Vdc, U min 7V, I min = 5.4 ma, fault probability <0 8 < fault at x 0 8 operations <0 8 < fault at x 0 8 operations <0 8 < fault at x 0 8 operations <0 8 < fault at x 0 8 operations Positively driven contacts to ZH /457 Yes Short-Circuit Rating without Welding Fuseless FAZ-B4/-HI FAZ-B4/-HI Fuse (A gg/gl) Terminal Capacity Solid or flexible conductor with ferrule (mm 2 ) Solid or stranded (AWG) Volume 5 Motor Control and Protection CA E April V5-T-77

22 . Undervoltage Release Description Current Limiter Description XTPAXCL Rated impulse withstand voltage (U imp), Vac 6000 Overvoltage category/pollution degree III/3 Rated operational voltage, U e (Vac) 690 Rated interrupted current = Rated operational current (l u = l e ) in amperes 63 XTPB, XTPR Single- and Two-Pole Circuits with DC and AC Current XTPAXUVR_ Cross-Section Solid or flexible conductor with ferrule (mm 2 ) x ( ) 2 x ( ) Solid or stranded (AWG) x (8 4) 2 x (8 4) Main Contact Rated operational voltage, U e (Vac) Rated operational voltage, U e (Vdc) Pickup voltage, x U s Dropout voltage, x U s Power Consumption Pickup AC (VA) 5 Sealing AC (VA) I > I > I > I > I > I > Protection of PVC Insulated Cables Against Thermal Overload at Short-Circuit Min. Cross-Section Protected V, 50 Hz, Cu mm Device Type XTPRP6BC The chart above indicates which minimum cable cross-sections are protected by XTPR motor protective circuit breakers up to their rated conditional short-circuit current Iq. Shunt Release Description XTPAXSR Cross-Section Solid or flexible conductor with ferrule (mm 2 ) x ( ) 2 x ( ) Solid or stranded (AWG) x (8 4) 2 x (8 4) Main Contact Rated operational voltage, U e (Vac) Rated operational voltage, U e (Vdc) AC operating range, x U s 0.7. DC operating range, x U s (intermittent operation 5s) 0.7. Power Consumption Pickup AC (VA) 5 Sealing AC (VA) 3 Pickup DC (VA) 3 Sealing DC (VA) 3... XTPR6P3BC XTPR00BC XTPR06BC XTPR020BC XTPR025BC XTPR06DC XTPR025DC XTPR032DC XTPR040DC XTPR050DC XTPR058DC XTPR063DC V5-T-78 Volume 5 Motor Control and Protection CA E April 203

23 . Wiring Diagrams Fuseless Installation with XTPR Backup Protection Diagram XTPR B Back-up protection range with XTPAXCL Rated short-circuit breaking capacity range XTPR B XTPR B 45 Vac cn cc Time/Current Curves Inherently short-circuit proof cc rms [ka] Characteristics The time/current characteristic, the current limiting characteristics and the I 2 t characteristics were determined in accordance with DIN VDE 0660 and IEC The tripping characteristic of the inverse-time delayed overload releases (thermal overload releases or a releases) for DC and AC with a frequency of 0 to 400 Hz also apply to the time/current characteristic. The characteristics apply to the cold state. At operating temperature, the tripping times of the thermal releases are reduced to approximately 25%. Under normal operating conditions, all three-poles of the device must be loaded. The three main conducting paths must be connected in series in order to protect single-phase or DC loads. With three-pole loading, the maximum deviation in the tripping time for 3 times the setting current and upwards is ±20% and thus in accordance with DIN VDE XTPR...B Inherently short-circuit-proof 50 XTPR B + XTPAXCL XTPR B Rated Current n [A] The tripping characteristics for the instantaneous, electromagnetic overcurrent releases (short-circuit releases or n releases) are based on the rated current I n, which is also the maximum value of the setting range for circuit breakers with adjustable overload releases. If the current is set to a lower value, the tripping current of the n release is increased by a corresponding factor. The characteristics of the electromagnetic overcurrent releases apply to frequencies of 50/60 Hz. Appropriate correction factors must be used for lower frequencies up to 6-2/3 Hz, for higher frequencies up to 400 Hz and for DC. Time/current characteristics, current limiting characteristics and I 2 t characteristics are available on request. Backup Protection Diagram XTPR D Back-up protection range with XTPAXCL Rated short-circuit breaking capacity range XTPR D MMP Tripping Characteristics XTPB, XTPR Frame B Milli-seconds Seconds Minutes XTPR Frame D Milli-seconds Seconds Minutes 2h h XTPR D 45 Vac cn cc Inherently short-circuit proof cc rms [ka] Inherently short-circuit-proof XTPB, XTPR Frame B x Rated Operational Current XTPR...D + XTPAXCL Rated Current n [A] XTPR D Rated Current n [A] XTPT XTPR Frame D x Rated Operational Current Volume 5 Motor Control and Protection CA E April V5-T-79

24 . MMP Let-Through Tripping Characteristics XTPB, XTPR Frame B I ^ D [ka] XTPR Frame D I ^ D [ka] XTPB XTPR Frame B XTPM 2 cc 32 A A 6 0 A/2 A 6.3 A 4.0 A 2.5 A.6 A 0.4 A U e = 400 V 0.25 A cc rms [ka] XTPR Frame D A 0.63 A XTPR Frame D i 2 dt [A 2 s] st half-wave 0 XTPR Frame D U e = 400 V 00 cc rms [ka] 63/58 A 50/40/32 A 25 A 6 A 2 cc 0 63/58 A 50/40/32 A 25 A 6 A U e = 400 V 0 00 cc rms [ka] V5-T-80 Volume 5 Motor Control and Protection CA E April 203

25 . Manual Motor Protector Short-Circuit Ratings Rated uninterrupted current I u = Rated operational current Ie. Rated conditional short-circuit current I q IEC/EN Rated ultimate short-circuit breaking capacity I cu IEC/EN Rated operational short-circuit breaking capacity I cs IEC/EN Global Use, IEC/EN XTPB with Classification Type and Type 2 I u I q I cu I cs Fuse 2 I q I cu I cs Fuse 2 I q I cu I cs Fuse 2 I q I cu I cs Fuse 2 I q I cu I cs Fuse 2 230V 400V 440V 500V 690V A ka ka ka A ka ka ka A ka ka ka A ka ka ka A ka ka ka A Global Use, IEC/EN XTPR BC with Classification Type and Type 2 I u 230V 400V 440V 500V 690V I q I cu I cs Fuse 2 I q I cu I cs Fuse 2 I q I cu I cs Fuse 2 I q I cu I cs Fuse 2 I q I cu I cs Fuse 2 A ka ka ka A ka ka ka A ka ka ka A ka ka ka A ka ka ka A N N N N N N N N N N N N N N N N N N N N N N N Notes N = Not required. 2 XTPR BC, XTPT, XTPM Required back-up fuse if the short-circuit current exceeds the rated conditional short-circuit current (I cc > I q ); XTPB, XTPR DC Fuse (A gg/gl) for enhancing the switching capacity of the motor protective circuit breaker to 00 ka. 3 No upstream protective device required, as it is the auto-protected range (00/50 ka Frame B, 50 ka Frame D). Volume 5 Motor Control and Protection CA E April V5-T-8

26 . Global Use, IEC/EN XTPR DC with Classification Type and Type 2 I u I q I cu I cs Fuse 2 I q I cu I cs Fuse 2 I q I cu I cs Fuse 2 I q I cu I cs Fuse 2 I q I cu I cs Fuse 2 230V 400V 440V 500V 690V A ka ka ka A ka ka ka A ka ka ka A ka ka ka A ka ka ka A N N N N Ratings for Group Motor Applications UL 508/CSA C22.2 No. 4 XTPB Frame B, Manual Motor Protector with Thermal and Magnetic Trip Rated Uninterrupted Current I u (Amps) FLA Adjustment Range/Overload Release I r (Amps) Short Circuit Release I rm (Amps) Maximum Protective Device for UL/CSA Group Protection Maximum rms Sym Current 480V (ka) w/current Limiter XTPAXCL Maximum Fuse Rating (A) w/current Limiter XTPAXCL Circuit Breaker Maximum (A) XTPBP6BC XTPBP25BC XTPBP40BC XTPBP63BC XTPB00BC XTPBP6BC XTPB2P5BC XTPB004BC XTPB6P3BC XTPB00BC XTPB02BC XTPB06BC XTPB020BC XTPB025BC w/current Limiter XTPAXCL Notes N = Not required. 2 XTPR BC, XTPT, XTPM Required back-up fuse if the short-circuit current exceeds the rated conditional short-circuit current (I cc > I q ); XTPB, XTPR DC Fuse (A gg/gl) for enhancing the switching capacity of the motor protective circuit breaker to 00 ka. 3 No upstream protective device required, as it is the auto-protected range (00/50 ka Frame B, 50 ka Frame D). 4 IEC/EN ka 600 Vac. V5-T-82 Volume 5 Motor Control and Protection CA E April 203

27 . UL 508/CSA C22.2 No. 4 XTPR Frame B (all Screw and Spring Cage Terminal Options), Manual Motor Protector with Thermal and Magnetic Trip UL 508/CSA C22.2 No. 4 XTPR Frame D, Manual Motor Protector with Thermal and Magnetic Trip Note 22 ka 600 Vac. Rated Uninterrupted Current I u (Amps) FLA Adjustment Range/Overload Release I r (Amps) Short Circuit Release I rm (Amps) Maximum Protective Device for UL/CSA Group Protection Maximum rms Sym Current 480V (ka) w/current Limiter XTPAXCL Maximum Fuse Rating (A) w/current Limiter XTPAXCL Circuit Breaker Maximum (A) XTPRP6BC XTPRP25BC XTPRP40BC XTPRP63BC XTPR00BC XTPRP6BC XTPR2P5BC XTPR004BC XTPR6P3BC XTPR00BC XTPR02BC XTPR06BC XTPR032BC XTPR025BC XTPR032BC Rated Uninterrupted Current I u (Amps) FLA Adjustment Range/Overload Release I r (Amps) Short Circuit Release I rm (Amps) Maximum Protective Device for UL/CSA Group Protection Maximum rms Sym Current 480V (ka) w/current Limiter XTPAXCL Maximum Fuse Rating (A) w/current Limiter XTPAXCL Circuit Breaker Maximum (A) XTPR06DC XTPR025DC XTPR032DC XTPR040DC XTPR050DC XTPR058DC XTPR063DC w/current Limiter XTPAXCL w/current Limiter XTPAXCL Volume 5 Motor Control and Protection CA E April V5-T-83

28 . UL 508 Type E Ratings XTPR Frame B + XTPAXLSA Manual Motor Protector Screw Terminal UL 508 Type E Ratings XTPR Frame D + XTPAXLSAD Note Line Side Adapter FLA Adjustment Range/Overload Release I r (Amps) Short Circuit Release I rm (Amps) UL 508 Type E Application Maximum rms Symmetrical Short-Circuit Ratings (ka) For UL 508 Type E applications, the manual motor protector assembly does not require a dedicated upstream protective device in the panel, thus a maximum rating is not required. 480/277V 600/347V Maximum Upstream Protective Device (A) Maximum Fuse 600V Maximum Circuit Breaker 600V XTPRP6BB XTPAXLSA Not required Not required XTPRP25BC XTPAXLSA Not required Not required XTPRP40BC XTPAXLSA Not required Not required XTPRP63BC XTPAXLSA Not required Not required XTPR00BC XTPAXLSA Not required Not required XTPRP6BC XTPAXLSA Not required Not required XTPR2P5BC XTPAXLSA Not required Not required XTPR004BC XTPAXLSA Not required Not required XTPR6P3BC XTPAXLSA Not required Not required XTPR00BC XTPAXLSA Not required Not required XTPR02BC XTPAXLSA Not required Not required XTPR06BC XTPAXLSA Not required Not required XTPR020BC XTPAXLSA Not required Not required XTPR025BC XTPAXLSA Not required Not required XTPR032BC XTPAXLSA Not required Not required Manual Motor Protector Screw Terminal Line Side Adapter FLA Adjustment Range/Overload Release I r (Amps) Short Circuit Release I rm (Amps) UL 508 Type E Application Maximum rms Symmetrical Short-Circuit Ratings (ka) 240V 480/277V 600/347V Maximum Upstream Protective Device (A) Maximum Fuse 600V Maximum Circuit Breaker 600V XTPR06DC XTPAXLSAD Not required Not required XTPR025DC XTPAXLSAD Not required Not required XTPR032DC XTPAXLSAD Not required Not required XTPR040DC XTPAXLSAD Not required Not required XTPR050DC XTPAXLSAD Not required Not required XTPR058DC XTPAXLSAD Not required Not required XTPR063DC XTPAXLSAD Not required Not required V5-T-84 Volume 5 Motor Control and Protection CA E April 203

29 . Dimensions Approximate Dimensions in mm [in] Manual Motor Protectors XTPB 93 [3.66] 45 [.77] 45 [.77] XTPAXFA_ Manual Motor Protector XTPR DC 30 [5.2] 40 [5.57] 30 [.8] 55 [2.7] Current Limiter XTPAXCL [3.54] [2.87] 45 [.77] 28 [.0] * IEC/EN 6075 DIN Rail 5.5 [.22] XTPAXFA_ * 7.5 [.30] 44 [.73] 49.5 [.95] 44 [.73] 74 [2.9] 85 [3.35] 7.5 [.30] 7.5 [.30] 70 [2.76] XTPAXFA_ 8 [4.65] 27 [5.00] 45 [5.7] 7 [6.73] 93 [3.66] Manual Motor Protectors, Manual Transformer Protectors XTPR B 93 [3.66] 45 [.77] 4 [.6] XTPAXFA_ [2.56] 25 [.77] [4.92] XTPAXFA_ 50 [.97] 88 [3.46] 94 [3.70] MMPs with Early-Make Auxiliary Contacts XTPR BC + XTPAXFAEM20 93 [3.66] 45 [.77] XTPAXFAEM20 80 [3.5] 50 [.97] 68 [2.68] 86 [3.39] 45 [.77] XTPAXFA_ [.77] [2.7] XTPAXFAEM20 Volume 5 Motor Control and Protection CA E April V5-T-85

30 . Approximate Dimensions in mm [in] Standard Auxiliary Contact XTPAXSA_ 9 [.35] Trip Indicating Auxiliary Contact XTPAXSATR_ 9 [.35] 36 [.42] [.77] [3.54] Undervoltage/Shunt Release XTPAXUVR_, XTPAXSR_ 8 [.7] 36 [.42] 36 [.42] 26 [.02] 26 [.02] 49 [.93] 68 [2.68] 68 [2.68] 68 [2.68] [.77] [3.54] [.77] [3.54] Three-Phase Commoning Link XTPAXCLKA4, XTPAXCLKA2 80 [7.09] (90 [3.54]) 45 [.77] 27 [.06] Three-Phase Commoning Link XTPAXCLKB5, XTPAXCLKB4, XTPAXCLKB3 and XTPAXCLKB2 Three-Phase Commoning Link XTPAXCLKC4, XTPAXCLKC2 Incoming Terminal, Line Side Adapter XTPAXIT, XTPAXLSA 7.5 [.30] 73 [2.87] 48 [.89] 26 [0.28] (207 [8.5], 53 [6.02], 99 [3.90]) 234 [9.2] (08 [4.25]) 56 [2.20] 4 [.6] 3 [.22] 54 [2.3] XTPAXLSA XTPAXIT 27 [.06] Overlapping Mounting to Extend the Three-Phase Commoning Link 63 [2.48] 27 [.06] V5-T-86 Volume 5 Motor Control and Protection CA E April 203

31 . Approximate Dimensions in mm [in] Three-Phase Commoning Link XTPAXCLKA4D, XTPAXCLKA3D and XTPAXCLKA2D XTPAXCLKC4D and XTPAXCLKC2D XTPAXCLKA4D XTPAXCLKC4D 36 [.42] 205 [8.07] 4 33 [.55] [.30] 36 [.42] 260 [0.24] 4 [.55] 33 [.30] XTPAXCLKA3D XTPAXCLKC2D 36 [.42] 5 [5.94] 4 [.55] 33 [.30] 36 [.42] 5 [4.53] 4 [.55] 33 [.30] XTPAXCLKA2D 36 [.42] XTPAXCLKB4D, XTPAXCLKB3D and XTPAXCLKB2D XTPAXCLKB4D 98 [3.86] 4 [.55] 33 [.30] 36 [.42] 232 [9.3] 4 [.55] 33 [.30] XTPAXCLKB3D 36 [.42] 70 [6.69] 4 [.55] 33 [.30] XTPAXCLKB2D 36 [.42] 7 [4.6] 4 [.55] 33 [.30] Volume 5 Motor Control and Protection CA E April V5-T-87

32 . Approximate Dimensions in mm [in] Insulated Enclosures for Surface Mounting of XTPB Manual Motor Protectors 58 [6.22] 80 [3.5] 6.5 [4.59] XTPBXENCS40, XTPBXENCS65, XTPBXENAS4, XTPBXENAS65 58 [6.22] 80 [3.5] 6.5 [4.59] 29.5 [5.0] XTPBXENCSLE65, XTPBXENCSLO65, XTPBXENASLE65, XTPBXENASO [6.22] Insulated Enclosures for Flush Mounting of XTPB Manual Motor Protectors 29 [5.08] 29 [5.08] 90.2 [3.55] XTPBXENCF40, XTPBXENCF [3.55] XTPBXENCFLE55, XTPBXENCFLO55 93 [3.66] 5.2 [4.54] 93 [3.66] 5.2 [4.54] 69 [2.72] 69 [2.72] 29 [5.08] 80 [3.5] 6.5 [4.59] 77.2 [6.98] XTPBXENCSEK65, XTPBXENCSES65, XTPBXENASEK65, XTPBXENASES [3.55] XTPBXENCFEK55, XTPBXENCFES55 93 [3.66] 5.2 [4.54] 75.9 [6.93] 69 [2.72] V5-T-88 Volume 5 Motor Control and Protection CA E April 203

33 . Approximate Dimensions in mm [in] Insulated Enclosures for Surface Mounting of XTPR B Manual Motor Protectors 58 [6.22] 80 [3.5] 90 [3.54] 00 [3.94] XTPAXENCS40 8 [7.3] 30 [.8] 44 [.73] 60 [6.30] 98 [3.86] 00 [3.94] 55 [2.7] 70 [2.76] SVB-PKZ0-CI 58 [6.22] 47.5 [.87] 04 [4.09] 80 [3.5] XTPAXENCS55_ + XTPAXPL, XTPAXENCSEM55_ + XTPAXPL XTPAXENCSH4, XTPAXENCS4, XTPAXENAS4 30 [.8] 44 [.73] 98 [3.86] 55 [2.7] SVB-PKZ0-CI 8 60 [7.3] [6.30] XTPAXENCS65_ + XTPAXPL, XTPAXENCSEM65_ + XTPAXPL 97 [3.82] 58 [6.22] 97.5 [3.84] 8 60 [7.3] [6.30] 80 [3.5] 97.5 [3.84] 25.5 [4.94] 4 [4.49] 30 [.8] 28 [.0] 00 [3.94] 33 [.30] 30 [.8] 28 [.0] 33 [.30] Drilling Dimensions 4.5 [.8] 53 [6.02] 4.5 [.8] 8 [.3] 47.5 [.87] 03 [4.06] 30 [5.2] Drilling Dimensions 4.5 [.8] 4.5 [.8] Drilling Dimensions M4 7 [6.73] M4 53 [6.02] XTPAXENCS55B, XTPAXENCS55RY, XTPAXENCSEM55B, XTPAXENCSEM55RY 8 [.3] Drilling Dimensions M4 7 [6.73] XTPAXENCS65B, XTPAXENCS65RY, XTPAXENCSEM65B, XTPAXENCSEM65RY, XTPAXENAS55B, XTPAXENAS55RY, XTPAXENASEM55B, XTPAXENASEM55RY, XTPAXENCSH65B, XTPAXENCSH65RY, XTPAXENCSEMH65B, XTPAXENCSEMH65RY M4 Volume 5 Motor Control and Protection CA E April V5-T-89

34 . Approximate Dimensions in mm [in] Insulated Enclosures for Flush Mounting of XTPR B Manual Motor Protectors 29 [5.08] 85 [3.35] 80 [3.5] 96 [3.78] 24 [4.88] XTPAXENCF40, XTPAXENCF55B, XTPAXENCF55RY 58 [2.28] 30 [.8] 80 [3.5] 96 [3.78] 24 [4.88] XTPAXENCF55_ + XTPAXPL3 98 [3.86] 55 [2.7] 55 [2.7] 29 [5.08] 85 [3.35] 69 [2.72] 28 [.0] 4 [.6] R 6 8 [ ] [ ] Mounting Cutout XTPAXENCF_ 30 [.8] 2 [.83] V5-T-90 Volume 5 Motor Control and Protection CA E April 203

35 . Approximate Dimensions in mm [in] Insulated Enclosures for Surface Mounting of XTPR D Manual Motor Protectors 3 [.2] 98 [3.86] 32 [.26] SVB-PKZ4-CI 240 [9.45] 72 [2.83] 60 [6.30] 34 [5.28] XTPAXENCSD65B, XTPAXENCSD65RY 8 [7.3] 97 [7.76] XTPAXENCSD65_ + XTPAXPL2 72 [2.83] Drilling Dimensions 5.6 [.22] Dia. 240 [9.45] 93 [7.60] XTPAXENCSD65 60 [6.30] 86 [7.32] 28 [.0] 30 [.8] 42 [5.60] Rotary Handle Mechanism XTPAXRHM_ 43 [.69] Dia. 64 [2.52] 48 [.89] 64 [2.52] 48 [.89] 9.5 [.77] 62 [2.44] At least 00 [3.94] up to Cover Hinge Mounting Depth: [ ] from the top edge of the mounting rail to the front edge of the panel door/cover Volume 5 Motor Control and Protection CA E April V5-T-9

36 . Approximate Dimensions in mm [in] Pushbutton MMP Enclosures Insulated Enclosures for Surface Mounting XTPB Pushbutton Motor- Protective Circuit Breakers H x W x D Global Usage XTPBXENCS40 58 x 80 x 6.5 [6.22 x 3.5 x 4.59] XTPBXENCS65 58 x 80 x 6.5 [6.22 x 3.5 x 4.59] XTPBXENCSLO65 58 x 80 x 29.5 [6.22 x 3.5 x 5.0] XTPBXENCSLE65 58 x 80 x 29.5 [6.22 x 3.5 x 5.0] XTPBXENCSES65 58 x 80 x 77.2 [6.22 x 3.5 x 6.98] XTPBXENCSEK65 58 x 80 x 77.2 [6.22 x 3.5 x 6.98] XTPB Pushbutton Manual Motor Protectors H x W x D Frame B (0. 32A) XTPR Motor-Protective Circuit Breakers H x W x D Global Usage XTPAXENCS4 60 x 00 x 04 [6.30 x 3.94 x 4.09] XTPAXENCS65B 60 x 00 x 30 [6.30 x 3.94 x 5.2] XTPAXENCS65RY 60 x 00 x 30 [6.30 x 3.94 x 5.2] XTPAXENCS40 58 x 80 x 00 [6.22 x 3.5 x 3.94] XTPAXENCS55B 58 x 80 x 25.5 [6.22 x 3.5 x 4.94] XTPAXENCS55RY 58 x 80 x 25.5 [6.22 x 3.5 x 4.94] Frame B (0. 32A) XTPR Rotary Manual Motor Protectors H x W x D Frame B XTPR (0. 32A) Rotary Motor-Protective Circuit Breakers with XTPAXFAEM20 Early-Make Front-Mount Auxiliary Contact H x W x D Global Usage XTPAXENCSEM65B 60 x 00 x 30 [6.30 x 3.94 x 5.2] XTPAXENCSEM65RY 60 x 00 x 30 [6.30 x 3.94 x 5.2] XTPAXENCSEM55B 58 x 80 x 00 [6.22 x 3.5 x 3.94] XTPAXENCSEM55RY 58 x 80 x 00 [6.22 x 3.5 x 3.94] Frame B XTPR (0. 32A) Rotary Manual Motor Protectors with XTPAXFAEM20 Early-Make Front-Mount Auxiliary Contact H x W x D Insulated Enclosures for Flush Mounting XTPB Pushbutton Manual Motor Protectors H x W x D Global and North American Usage XTPBXENCF40 29 x 90.2 x 5.2 [5.08 x 3.55 x 4.54] XTPBXENCF55 29 x 90.2 x 5.2 [5.08 x 3.55 x 4.54] XTPBXENCFLO55 29 x 90.2 x 5.2 [5.08 x 3.55 x 4.54] XTPBXENCFLE55 29 x 90.2 x 5.2 [5.08 x 3.55 x 4.54] XTPBXENCFES55 29 x 90.2 x 75.9 [5.08 x 3.55 x 6.93] XTPBXENCFEK55 29 x 90.2 x 75.9 [5.08 x 3.55 x 6.93] Frame B (0. 32A) XTPR Rotary Manual Motor Protectors H x W x D North American Usage XTPBXENAS4 58 x 80 x 6.5 [6.22 x 3.5 x 4.59] XTPBXENAS65 58 x 80 x 6.5 [6.22 x 3.5 x 4.59] XTPBXENASLO65 58 x 80 x 29.5 [6.22 x 3.5 x 5.0] XTPBXENASLE65 58 x 80 x 29.5 [6.22 x 3.5 x 5.0] XTPBXENASES65 58 x 80 x 77.2 [6.22 x 3.5 x 6.98] XTPBXENASEK65 58 x 80 x 77.2 [6.22 x 3.5 x 6.98] North American Usage XTPAXENAS55B 60 x 00 x 30 [6.30 x 3.94 x 5.2] XTPAXENAS55RY 60 x 00 x 30 [6.30 x 3.94 x 5.2] North American Usage XTPAXENCSEM55B 60 x 00 x 30 [6.30 x 3.94 x 5.2] XTPAXENCSEM55RY 60 x 00 x 30 [6.30 x 3.94 x 5.2] Frame D (0 65A) Rotary Motor-Protective Circuit Breakers H x W x D Global and North American Usage XTPAXENCSD65B 240 x 60 x 97 [9.45 x 6.30 x 7.76] XTPAXENCSD65RY 240 x 60 x 97 [9.45 x 6.30 x 7.76] Global Usage XTPAXENCF40 29 x 85 x 96 [5.08 x 3.35 x 3.78] XTPAXENCF55B 29 x 85 x 24 [5.08 x 3.35 x 4.88] XTPAXENCF55RY 29 x 85 x 24 [5.08 x 3.35 x 4.88] V5-T-92 Volume 5 Motor Control and Protection CA E April 203

37 . Combination Motor Controllers Combination Motor Controllers Product Description Eaton s XT IEC open nonreversing and reversing manual motor controllers combine a manual motor protector with an IEC contactor(s) to provide a complete motor protection solution by combining motor disconnect function, thermal overload protection, magnetic short-circuit protection and remote control operation in one compact, assembled unit. these assembled manual motor controllers cover motors with FLA ratings from 0.0A to 65A. The UL 508 Type F labeled combination motor controller (CMC) includes a line side adapter (LSA). These assembled combination motor controllers cover motors with FLA ratings from 0.0A to 65A. Application Description The XT IEC non-reversing and reversing manual and combination motor controllers can be used in the following applications: Group Motor Control Manual motor controllers (MMCs) are ideal for group motor applications where an upstream breaker or fuse provides protection for two or more motors. XT manual motor controllers (MMC) combine a manual motor protector, a wiring connector link and IEC contactor. Contents Description Relays and Timers Miniature Controls Contactors and Starters Thermal Overload Relays C440/XT Electronic Overload Relay Manual Motor Protectors Combination Motor Controllers Features Standards and Certifications Selection Product Selection Accessories Technical Data and Specifications Dimensions An Eaton Green Solution XT Electronic Manual Motor Protector Reference Data Individual Branch Circuit for Motor Loads Combination motor controller (CMC), consisting of a line side adapter, manual motor protector, wiring connector link and IEC contactor, provide an efficient means to build an entire branch circuit. The XT CMC is UL 508 Type F approved, meaning it is self-protected and doesn t require the use of an additional fuse or breaker for short circuit protection. This approval means CMC s can be used in place of a traditional fuse-starter and breaker-starter motor circuit. Based around two key functional components (MMP and contactor), the CMC is a very cost effective means to build a branch circuit. Fuses and breakers must be oversized to prevent tripping during motor start up, and thus these oversized devices can no longer protect the motor. To compensate for this, a motor overload relay is necessary to protect the motor. Page V5-T-3 V5-T-8 V5-T-35 V5-T-28 V5-T-4 V5-T-57 V5-T-94 V5-T-94 V5-T-95 V5-T-95 V5-T-203 V5-T-205 V5-T-2 V5-T-26 V5-T-229 The manual motor protector was invented in Germany by Moeller to correct this inefficiency. The MMP operates similarly to a circuit breaker, except the inrush (magnetic) protection is set to 4 times the running current, thus accounting for motor start-up current without the necessity to oversize. A overcurrent dial was added to the face of the MMP to serve as the motor overload protection. This motor protective circuit breaker, as it is referred to in Europe, now accomplishes all four key functions of a motor branch circuit: disconnect, short circuit, motor controller and motor overload protection. With the addition of a contactor, users have the ability to remotely control the starter device. Whether a single motor application or a multiple motor application, CMC s are an ideal solution for machinery OEMs and panel builders. Volume 5 Motor Control and Protection CA E April V5-T-93

38 . Features ON/OFF rotary handle with lockout provision Visible trip indication Test trip function Motor applications from 0.0A to 65A Class 0 overload protection Built-in heater and magnetic trip elements to protect the motor Phase loss sensitivity Type 2 coordination Ambient compensated up to 55 C [40 F] Control inputs located at front of starter for easy access and wiring Wide range of coils DIN rail mount XTSC BB_ Mounting plates XTSC BC_, XTSC D motor controllers Adjustment dial for setting motor FLA Short-circuit trip at 4 times the maximum setting of the FLA adjustment dial UL 508 Type F CMC high fault short-circuit ratings NO-NC auxiliary contact as standard on manual motor controller and combination motor controller Standards and Certifications UL 508 Type F combination motor controller IEC Type 2 Approved per IEC UL Listed File No. E CE Mark Note: For Type 2 Coordination of MMCs, see Page V5-T-230. Protection in different controller types MMC and CMC Applications Manual Motor Controller Use in group installation applications. Upstream SCPD is required and must be sized smaller than the maximum upstream SCPD rating on each MMC 2 used. Tap Line rules Side should Adapter also be (LSA) observed. Not required Manual Motor Controller XTSC/XTSR XTIEC Manual and Combination Motor Controllers Notes Technical Paper AP E. Line side adapters are not required for non-u.s. applications. Most countries outside of the U.S. classify the MMP as a motor-protective circuit breaker. SCPD = Short-circuit protective device (circuit breaker, fuses). 2 MMC = Manual motor controller UL 508 Type F Combination Motor Controller Use for single motor branch circuits or use multiple CMC s for a multiple motor panel applications. No additional SCPD is required in the branch, as these devices are selfprotected. Line Side Adapter (LSA) Required factory assembled Combination Motor Controller XTFC/XTFR V5-T-94 Volume 5 Motor Control and Protection CA E April 203

39 . Selection Combination Motor Controllers Designation XT = XT IEC power control Product Selection SC SR FC FR XTSC and XTSR Manual Motor Controllers (MMC)/Starter Combinations Frame B MMP + Frame B Contactor Factory-Assembled Manual Motor Controller Frame B MMP + Frame B Contactor Maximum UL Ratings FLA Adjustment Range/Overload Release I r (Amps) Type = Manual motor controller FVNR = Manual motor controller FVR = Combination motor controller, UL 508 Type F FVNR = Combination motor controller, UL 508 Type F FVR Short-Circuit Release I rm (Amps) XT SC 02 B B A Three-Phase Rated Current of MMP Frame B P6 = 0.6A P25 = 0.25A P40 = 0.40A P63 = 0.63A 00 = A P6 =.6A 2P5 = 2.5A 004 = 4A 6P3 = 6.3A 00 = 0A 02 = 2A 06 = 6A 020 = 20A 025 = 25A 032 = 32A Frame D 06 = 6A 025 = 25A 032 = 32A 040 = 40A 050 = 50A 058 = 58A 063 = 63A 200V 240V 480V 600V Frame Size Contactor B = 45 mm, 7 to 5A C = 45 mm, 8 to 32A D = 55 mm, 40 to 65A Frame Size MMP B = 45 mm, 0. to 32A D = 55 mm, 6 to 63A Notes Select manual motor controllers by full load amperes. Maximum motor ratings (kw, hp) are for reference only. 2 Underscore (_) indicates magnetic coil suffix required. See Page V5-T In this range, calculate motor rating according to rated current. Specified values to NEC 430.6(A)(). Assembled Manual Motor Controller 2 Non-Reversing Coil Voltage A = 0V 50 Hz, 20V 60 Hz B = 220V 50 Hz, 240V 60 Hz C = 45V 50 Hz, 480V 60 Hz D = 600V 60 Hz E = 208V 50 Hz F = 230V 50 Hz G = 90V 50 Hz, 220V 60 Hz H = 240V 50 Hz, 277V 60 Hz L = 380V 50 Hz, 440V 60 Hz N = 400V 50 Hz P = 380V 60 Hz R = 2V 50/60 Hz T = 24V 50/60 Hz W = 42V 50 Hz, 48V 60 Hz Y = 48V 50 Hz AD = 20 Vdc BD = 220 Vdc RD =2 Vdc TD =24 Vdc WD =48 Vdc Reversing /2 /2 XTSCP6BB_ XTSRP6BB_ /2 /2 XTSCP25BB_ XTSRP25BB_ /2 /2 XTSCP40BB_ XTSRP40BB_ /2 /2 XTSCP63BB_ XTSRP63BB_ /2 /2 XTSC00BB_ XTSR00BB_ /4 XTSCP6BB_ XTSRP6BB_ /2 /2 -/2 XTSC2P5BB_ XTSR2P5BB_ XTSC004BB_ XTSR004BB_ /2 -/2 3 5 XTSC6P3BB_ XTSR6P3BB_ /2 3 XTSC00BB_ XTSR00BB_ /2 3 XTSC02BB_ XTSR02BB_ XTSC06BB_ Volume 5 Motor Control and Protection CA E April V5-T-95

40 . Frame B MMP + Frame B Contactor Frame B MMP + Frame C Contactor Frame B MMP + Frame C Contactor Factory-Assembled Motor Protective Device with Thermal and Magnetic Trip + Contactor Maximum IEC Ratings FLA Adjustment Range/Overload Release I r (Amps) Short-Circuit Release I rm (Amps) Three-Phase Assembled Manual Motor Controller V V Factory-Assembled Manual Motor Controller Frame B MMP + Frame C Contactor Maximum UL Ratings Factory-Assembled Manual Motor Controller Frame B MMP + Frame C Contactor Maximum IEC RatingS Notes Select manual motor controllers by full load amperes. Maximum motor ratings (kw, hp) are for reference only. 2 Underscore (_) indicates magnetic coil suffix required. See Page V5-T V V Non-Reversing Reversing XTSCP6BB_ XTSRP6BB_ XTSCP25BB_ XTSRP25BB_ XTSCP40BB_ XTSRP40BB_ XTSCP63BB_ XTSRP63BB_ XTSC00BB_ XTSR00BB_ XTSCP6BB_ XTSRP6BB_ XTSC2P5BB_ XTSR2P5BB_ XTSC004BB_ XTSR004BB_ XTSC6P3BB_ XTSR6P3BB_ XTSC00BB_ XTSR00BB_ XTSC02BB_ XTSR02BB_ XTSC06BB_ FLA Adjustment Range/Overload Release I r (Amps) Short-Circuit Release I rm (Amps) Three-Phase 200V 240V 480V 600V Assembled Manual Motor Controller 2 Non-Reversing Reversing XTSC06BC_ XTSR06BC_ XTSC020BC_ XTSR020BC_ / XTSC025BC_ XTSR025BC_ / XTSC032BC_ XTSR032BC_ FLA Adjustment Range/Overload Release I r (Amps) Short-Circuit Release I rm (Amps) Three-Phase Assembled Manual Motor Controller V V 500V V Non-Reversing Reversing XTSC06BC_ XTSR06BC_ XTSC020BC_ XTSR020BC_ XTSC025BC_ XTSR025BC_ XTSC032BC_ XTSR032BC_ V5-T-96 Volume 5 Motor Control and Protection CA E April 203

41 . Frame D MMP + Frame C Contactor Frame D MMP + Frame C Contactor Frame D MMP + Frame D Contactor Factory-Assembled Manual Motor Controller Frame D MMP + Frame C Contactor Maximum UL Ratings FLA Adjustment Range/Overload Release I r (Amps) Short-Circuit Release I rm (Amps) Three-Phase 200V 240V 480V 600V Factory-Assembled Manual Motor Controller Frame D MMP + Frame C Contactor Maximum IEC Ratings Factory-Assembled Manual Motor Controller Frame D MMP + Frame D Contactor Maximum UL Ratings Notes Select manual motor controllers by full load amperes. Maximum motor ratings (kw, hp) are for reference only. 2 Underscore (_) indicates magnetic coil suffix required. See Page V5-T-98. Assembled Manual Motor Controller 2 Non-Reversing Reversing XTSC06DC_ XTSR06DC_ / XTSC025DC_ XTSR025DC_ / XTSC032DC_ XTSR032DC_ FLA Adjustment Range/Overload Release I r (Amps) Short-Circuit Release I rm (Amps) Three-Phase Assembled Manual Motor Controller V V 500V V Non-Reversing Reversing XTSC06DC_ XTSR06DC_ XTSC025DC_ XTSR025DC_ XTSC032DC_ XTSR032DC_ FLA Adjustment Range/Overload Release I r (Amps) Short-Circuit Release I rm (Amps) Three-Phase 200V 240V 480V 600V Assembled Manual Motor Controller 2 Non-Reversing Reversing XTSC040DD_ XTSR040DD_ XTSC050DD_ XTSR050DD_ XTSC058DD_ XTSR058DD_ XTSC063DD_ XTSR063DD_ Volume 5 Motor Control and Protection CA E April V5-T-97

42 . Frame D MMP + Frame D Contactor AC and DC Coil Suffixes Coil Voltage Suffix Code Frame B Contactors 0V 50 Hz, 20V 60 Hz A 220V 50 Hz, 240V 60 Hz B 230V 50 Hz F 24V 50/60 Hz T 24 Vdc TD 3 45V 50 Hz, 480V 60 Hz C 600V 60 Hz D 208V 60 Hz E 90V 50 Hz, 220V 60 Hz G 240V 50 Hz, 277V 60 Hz H Factory-Assembled Manual Motor Controller Frame D MMP + Frame D Contactor Maximum IEC Ratings FLA Adjustment Range/Overload Release I r (Amps) Notes The assembled manual motor controller (MMC) consists of an XTPR manual motor protector (MMP) and an XTCE contactor. For Frame B MMP + Frame B contactor assemblies, the XTSC and XTSR can be mounted directly on DIN rail without an adapter. The contactors are supported mechanically with a mechanical connection element (included in XTPAXTPCB, XTPAXRPCRB). For MMCs using a Frame C or Frame D contactor, the assembly is mounted via a DIN rail adapter plate (XTPAXTPCPC, XTPAXTPCPD) and the electrical connection is made with electrical contact modules (XTPAXECMC, XTPAXECMD), both included in XTPAXTPCC and XTPAXTPCD. Service Factor (SF) Setting Ir of current scale in dependence of load factor: SF =.5 I r = x I n mot SF = I r = 0.9 x I n mot Single-phasing sensitivity to IEC/EN , VDE 0660 Part 02. Select manual motor controllers by full load amperes. Maximum motor ratings (kw, hp) are for reference only. 2 Underscore (_) indicates magnetic coil suffix required. See AC and DC coil suffixes above. 3 With DC operation: Integrated diode-resistor combination, coil rating 2.6W. Non-Reversing Manual Motor Controller Power Circuit M 3 ~ Short-Circuit Release I rm (Amps) Reversing Manual Motor Controller Power Circuit Three-Phase Assembled Manual Motor Controller V V 500V V Non-Reversing Reversing XTSC040DD_ XTSR040DD_ XTSC050DD_ XTSR050DD_ XTSC058DD_ XTSR058DD_ XTSC063DD_ XTSR063DD_ Coil Voltage Suffix Code 380V 50 Hz, 440V 60 Hz L 400V 50 Hz N 380V 60 Hz P 2V 50/60 Hz R 42V 50 Hz, 48V 60 Hz W 48V 50 Hz Y 20 Vdc AD Vdc BD 3 2 Vdc RD 3 48 Vdc WD 3 M 3 ~ Coil Voltage Suffix Code Frame C and D Contactors 0V 50 Hz, 20V 60 Hz A 220V 50 Hz, 240V 60 Hz B 230V 50 Hz F 24V 50/60 Hz T Vdc TD 3 45V 50 Hz, 480V 60 Hz C 550V 50 Hz, 600V 60 Hz D 208V 60 Hz E 90V 50 Hz, 220V 60 Hz G 240V 50 Hz, 277V 60 Hz H Coil Voltage Suffix Code 380V 50 Hz, 440V 60 Hz L 400V 50 Hz N 380V 60 Hz P 2V 50/60 Hz R 42V 50 Hz, 48V 60 Hz W 48V 50 Hz Y 0 30 Vdc AD Vdc BD Vdc RD Vdc WD 3 V5-T-98 Volume 5 Motor Control and Protection CA E April 203

43 . XTFC and XTFR Combination Motor Controllers (CMC), UL 508 Type F Frame B MMP + Two Frame B Contactors Factory-Assembled Type F Combination Motor Controller Frame B MMP + Frame B Contactor Maximum UL Ratings FLA Adjustment Range/Overload Release I r (Amps) Short-Circuit Release I rm (Amps) Three-Phase 200V 240V 480V 600V Factory-Assembled Type F Combination Motor Controller Frame B MMP + Frame B Contactor Maximum IEC Ratings Notes Select combination motor controllers by full load amperes. Maximum motor ratings (kw, hp) are for reference only. 2 Underscore (_) indicates magnetic coil suffix required. See Page V5-T In this range, calculate motor rating according to rated current. Specified values to NEC 430.6(A)(). Assembled Manual Motor Controller 2 Non-Reversing Reversing /2 /2 XTFCP25BB_ XTFRP25BB_ /2 /2 XTFCP40BB_ XTFRP40BB_ /2 /2 XTFCP63BB_ XTFRP63BB_ /2 /2 XTFC00BB_ XTFR00BB_ /4 XTFCP6BB_ XTFRP6BB_ /2 /2 -/2 XTFC2P5BB_ XTFR2P5BB_ XTFC004BB_ XTFR004BB_ /2 -/2 3 5 XTFC6P3BB_ XTFR6P3BB_ /2 0 XTFC00BB_ XTFR00BB_ /2 XTFC02BB_ XTFR02BB_ XTFC06BB_ FLA Adjustment Range/Overload Release I r (Amps) Short-Circuit Release I rm (Amps) Three-Phase Assembled Manual Motor Controller V V 500V V Non-Reversing Reversing XTFCP6BB_ XTFRP6BB_ XTFCP25BB_ XTFRP25BB_ XTFCP40BB_ XTFRP40BB_ XTFCP63BB_ XTFRP63BB_ XTFC00BB_ XTFR00BB_ XTFCP6BB_ XTFRP6BB_ XTFC2P5BB_ XTFR2P5BB_ XTFC004BB_ XTFR004BB_ XTFC6P3BB_ XTFR6P3BB_ XTFC00BB_ XTFR00BB_ XTFC02BB_ XTFR02BB_ XTFC06BB_ Volume 5 Motor Control and Protection CA E April V5-T-99

44 . Factory-Assembled Type F Combination Motor Controller Frame B MMP + Frame C Contactor Maximum UL Ratings FLA Adjustment Range/Overload Release I r (Amps) Short-Circuit Release I rm (Amps) Three-Phase 200V 240V 480V 600V Factory-Assembled Type F Combination Motor Controller Frame B MMP + Frame C Contactor Maximum IEC Ratings Notes Select combination motor controllers by full load amperes. Maximum motor ratings (kw, hp) are for reference only. 2 Underscore (_) indicates magnetic coil suffix required. See Page V5-T-202. Assembled Manual Motor Controller 2 Non-Reversing Reversing XTFC06BC_ XTFR06BC_ XTFC020BC_ XTFR020BC_ /2 5 XTFC025BC_ XTFR025BC_ / XTFC032BC_ XTFR032BC_ FLA Adjustment Range/Overload Release I r (Amps) Short-Circuit Release I rm (Amps) Three-Phase Assembled Manual Motor Controller V V 500V V Non-Reversing Reversing XTFC06BC_ XTFR06BC_ XTFC020BC_ XTFR020BC_ XTFC025BC_ XTFR025BC_ XTFC032BC_ XTFR032BC_ V5-T-200 Volume 5 Motor Control and Protection CA E April 203

45 . Factory-Assembled Type F Combination Motor Controller Frame D MMP + Frame C Contactor Maximum UL Ratings FLA Adjustment Range/Overload Release I r (Amps) Short-Circuit Release I rm (Amps) Three-Phase 200V 240V 480V 600V Factory-Assembled Type F Combination Motor Controller Frame D MMP + Frame C Contactor Maximum IEC Ratings Factory-Assembled Type F Combination Motor Controller Frame D MMP + Frame D Contactor Maximum UL Ratings Notes Select combination motor controllers by full load amperes. Maximum motor ratings (kw, hp) are for reference only. 2 Underscore (_) indicates magnetic coil suffix required. See Page V5-T-202. Assembled Manual Motor Controller 2 Non-Reversing Reversing XTFC06DC_ XTFR06DC_ / XTFC025DC_ XTFR025DC_ / XTFC032DC_ XTFR032DC_ FLA Adjustment Range/Overload Release I r (Amps) Short-Circuit Release I rm (Amps) Three-Phase Assembled Manual Motor Controller V V 500V V Non-Reversing Reversing XTFC06DC_ XTFR06DC_ XTFC025DC_ XTFR025DC_ XTFC032DC_ XTFR032DC_ FLA Adjustment Range/Overload Release I r (Amps) Short-Circuit Release I rm (Amps) Three-Phase 200V 240V 480V 600V Assembled Manual Motor Controller 2 Non-Reversing Reversing XTFC040DD_ XTFR040DD_ XTFC050DD_ XTFR050DD_ XTFC058DD_ XTFR058DD_ XTFC063DD_ XTFR063DD_ Volume 5 Motor Control and Protection CA E April V5-T-20

46 . AC and DC Coil Suffixes Coil Voltage Suffix Code Frame B Contactors 0V 50 Hz, 20V 60 Hz A 220V 50 Hz, 240V 60 Hz B 230V 50 Hz F 24V 50/60 Hz T 24 Vdc TD 3 45V 50 Hz, 480V 60 Hz C 600V 60 Hz D 208V 60 Hz E 90V 50 Hz, 220V 60 Hz G 240V 50 Hz, 277V 60 Hz H Factory-Assembled Type F Combination Motor Controller Frame D MMP + Frame D Contactor Maximum IEC Ratings Notes The assembled manual motor controller (MMC) consists of an XTPR manual motor protector (MMP) and an XTCE contactor. For Frame B MMP + Frame B contactor assemblies, the XTSC and XTSR can be mounted directly on DIN rail without an adapter. The contactors are supported mechanically with a mechanical connection element (included in XTPAXTPCB, XTPAXRPCRB). For 6A and above, the assembly is mounted via a DIN rail adapter plate (XTPAXTPCPC, XTPAXTPCPD) and the electrical connection is made with electrical contact modules (XTPAXECMC, XTPAXECMD), both included in XTPAXTPCC and XTPAXTPCD. Service Factor (SF) Setting I r of current scale in dependence of load factor: SF =.5 I r = x I n mot SF = I r = 0.9 x I n mot Single-phasing sensitivity to IEC/EN , VDE 0660 Part 02. Select combination motor controllers by full load amperes. Maximum motor ratings (kw, hp) are for reference only. 2 Underscore (_) indicates magnetic coil suffix required. See AC and DC coil suffixes above. 3 With DC operation: Integrated diode-resistor combination, coil rating 2.6W. XTFC Manual Motor Controller M 3 ~ FLA Adjustment Range/Overload Release I r (Amps) Short-Circuit Release I rm (Amps) XTFR Manual Motor Controller Three-Phase Assembled Manual Motor Controller V V 500V V Non-Reversing Reversing XTFC040DD_ XTFR040DD_ XTFC050DD_ XTFR050DD_ XTFC058DD_ XTFR058DD_ XTFC063DD_ XTFR063DD_ Coil Voltage Suffix Code 380V 50 Hz, 440V 60 Hz L 400V 50 Hz N 380V 60 Hz P 2V 50/60 Hz R 42V 50 Hz, 48V 60 Hz W 48V 50 Hz Y 20 Vdc AD Vdc BD 3 2 Vdc RD 3 48 Vdc WD 3 M 3 ~ Coil Voltage Suffix Code Frame C and D Contactors 0V 50 Hz, 20V 60 Hz A 220V 50 Hz, 240V 60 Hz B 230V 50 Hz F 24V 50/60 Hz T Vdc TD 3 45V 50 Hz, 480V 60 Hz C 550V 50 Hz, 600V 60 Hz D 208V 60 Hz E 90V 50 Hz, 220V 60 Hz G 240V 50 Hz, 277V 60 Hz H Coil Voltage Suffix Code 380V 50 Hz, 440V 60 Hz L 400V 50 Hz N 380V 60 Hz P 2V 50/60 Hz R 42V 50 Hz, 48V 60 Hz W 48V 50 Hz Y 0 30 Vdc AD Vdc BD Vdc RD Vdc WD 3 V5-T-202 Volume 5 Motor Control and Protection CA E April 203

47 . Accessories Line Side Adapters Line side adapters are required for use with XTPR MMPs only when used as Type E self-protected manual combination starters or as part of XTFC or XTFR Type F combination motor controllers. Not required for group installation. XTPAXLSA XTPAXLSA Line Side Adapters Description For use with Frame B MMPs (up to 32A) For use with Frame D MMPs (up to 40A) Combination Connection Kits Combination connection kits include the necessary components to field assemble a manual motor controller with an MMP (XTPR) and contactor (XTCE). XTPAXTPCB XTPAXTPCC and XTPAXTPCD XTPAXTPCRB XTPAXTPCRC Non-Reversing Starters For Use with Reversing Starters Note XTPAXLSA XTPAXLSAD Description/Composed of Orders must be placed in multiples of package quantity listed. Std. Pack XTPR B + XTCE B Mechanical connection element for XTPR B and contactor XTPAXTPCB Main current wiring between XTPR B and contactor in toolless plug connection Cable guidance Use as contactor auxiliary switch XTCEXFAT_. Control cable guidance: max. six cables up to 2.5 mm 2 external diameter or four cables up to 3.5 mm 2 external diameter XTPR B + XTCE C DIN rail adapter plate XTPAXTPCC XTPR D + XTCE D Main current wiring between XTPR and contactor XTPAXTPCD For Use with Description/Composed of Std. Pack XTPR B + XTCE B0_ Mechanical connection element for XTPR B and contactor XTPAXTPCRB Reversing starter main current wiring in toolless plug connection Control cables for electrical interlocking in toolless plug connection KM: A K2M: 2, KM: 2 K2M: A, KM: A2 K2M: A2 Cable guidance Use as contactor auxiliary switch XTCEXFAT_. Control cable guidance: max. six cables up to 2.5 mm 2 external diameter or four cables up to 3.5 mm 2 external diameter. XTPR B + XTCE C DIN rail adapter plate XTPAXTPCRB Reversing starter main current wiring Volume 5 Motor Control and Protection CA E April V5-T-203

48 . XTPAXEC_ XTPAXTPCPB XTPAXTPCRPB XTPAXTPCPD Electric Contact Module For Use with DIN Rail Adapter Plates Lateral Module Connection Element Note Description/Composed of Orders must be placed in multiples of package quantity listed. Std. Pack XTPR B + XTCE C Main current wiring between XTPR B and contactor 5 XTPAXECMC Use only in combination with busbar adapter XTPR D + XTCE D Main current wiring between XTPR D and contactor 5 XTPAXECMD Use only in combination with busbar adapter For Use with XTPAXTPCB XTPAXTPCRB XTPR B + XTCE C XTPAXECMC XTPAXECMD XTPR D + XTCE C XTPR D + XTCE D For Use with Description/Composed of Std. Pack 45 mm wide adapter plate with one DIN rail 4 XTPAXTPCPB Connection element for side-by-side positioning of further plates 45 mm wide adapter plate with one DIN rail 4 XTPAXTPCRPB Connection element for side-by-side positioning of further plates 55 mm wide adapter plate with two DIN rails 4 XTPAXTPCPD Connection cams for further plates 4 For use with reversing and star-delta starters Description/Composed of Std. Pack Can be grouped on the DIN rail adapter 0 XTPAXLM For Use with Expansion of the mounting width by 9 mm Description/Composed of Std. Pack For connection of several DIN rail adapters 50 XTPAXCNE V5-T-204 Volume 5 Motor Control and Protection CA E April 203

49 . Technical Data and Specifications XTSC Non-Reversing Manual Motor Controllers (MMC) Component Bill of Material Factory Assembled Manual Motor Protector + Contactor FLA Adjustment Component s Assembled Manual Range/Overload Manual Motor Combination Manual Motor Protector Motor Controller Release I r (Amps) Protector Connection Kit Contactor Auxiliary Contact XTSC Frame B MMP + Frame B Contactor XTSCP6BB_ XTPRP6BC XTPAXTPCB XTCE007B0_ XTPAXFA XTSCP25BB_ XTPRP25BC XTPAXTPCB XTCE007B0_ XTPAXFA XTSCP40BB_ XTPRP40BC XTPAXTPCB XTCE007B0_ XTPAXFA XTSCP63BB_ XTPRP63BC XTPAXTPCB XTCE007B0_ XTPAXFA XTSC00BB_ 0.63 XTPR00BC XTPAXTPCB XTCE007B0_ XTPAXFA XTSCP6BB_.6 XTPRP6BC XTPAXTPCB XTCE007B0_ XTPAXFA XTSC2P5BB_ XTPR2P5BC XTPAXTPCB XTCE007B0_ XTPAXFA XTSC004BB_ XTPR004BC XTPAXTPCB XTCE007B0_ XTPAXFA XTSC6P3BB_ XTPR6P3BC XTPAXTPCB XTCE007B0_ XTPAXFA XTSC00BB_ XTPR00BC XTPAXTPCB XTCE009B0_ XTPAXFA XTSC02BB_ 8 2 XTPR02BC XTPAXTPCB XTCE02B0_ XTPAXFA XTSC06BB_ 0 6 XTPR06BC XTPAXTPCB XTCE05B0_ XTPAXFA XTSC Frame B MMP + Frame C Contactor XTSC06BC_ 0 6 XTPR06BC XTPAXTPCC XTCE08C0_ XTPAXFA XTSC020BC_ 6 20 XTPR020BC XTPAXTPCC XTCE025C0_ XTPAXFA XTSC025BC_ XTPR025BC XTPAXTPCC XTCE025C0_ XTPAXFA XTSC032BC_ XTPR032BC XTPAXTPCC XTCE032C0_ XTPAXFA XTSC Frame D MMP + Frame C Contactor XTSC06DC_ 0 6 XTPR06DC 2 XTCE08C0_ XTPAXFA XTSC025DC_ 6 25 XTPR025DC 2 XTCE025C0_ XTPAXFA XTSC032DC_ XTPR032DC 2 XTCE032C0_ XTPAXFA XTSC Frame D MMP + Frame D Contactor XTSC040DD_ XTPR040DC XTPAXTPCD 3 XTCE040D00_ XTPAXFA XTSC050DD_ XTPR050DC XTPAXTPCD 3 XTCE050D00_ XTPAXFA XTSC058DD_ XTPR058DC XTPAXTPCD 3 XTCE065D00_ XTPAXFA XTSC063DD_ XTPR063DC XTPAXTPCD 3 XTCE065D00_ XTPAXFA Notes Underscore (_) indicates magnetic coil suffix required. See Page V5-T The connection between the XTPR DC and the XTCE C_ contactor will be made with flexible wire and mounted to the DIN rail adapter plate (XTPAXTPCPD). 3 The reversing connection between the XTPR DC and the (2) XTCE C_ contactors will be accomplished by using the non-reversing combination connection kit (XTPAXTPCD), Frame D reversing link kit (XTCEXRLD), additional DIN rail adapter plate (XTPAXTPCPD) and DIN adapter connection element (XTPAXCNE). Volume 5 Motor Control and Protection CA E April V5-T-205

50 . XTSR Reversing Manual Motor Controllers (MMC) Component Bill of Material Factory Assembled Manual Motor Protector + Contactor FLA Adjustment Component s Assembled Manual Range/Overload Manual Motor Combination Manual Motor Protector Motor Controller Release I r (Amps) Protector Connection Kit Contactor Auxiliary Contact XTSR Frame B MMP + Frame B Contactor XTSRP6BB_ XTPBP6BC XTPAXTPCRB (2) XTCE007B0_ XTPAXFA XTSRP25BB_ XTPRP25BC XTPAXTPCRB (2) XTCE007B0_ XTPAXFA XTSRP40BB_ XTPRP40BC XTPAXTPCRB (2) XTCE007B0_ XTPAXFA XTSRP63BB_ XTPRP63BC XTPAXTPCRB (2) XTCE007B0_ XTPAXFA XTSR00BB_ 0.63 XTPR00BC XTPAXTPCRB (2) XTCE007B0_ XTPAXFA XTSRP6BB_.6 XTPRP6BC XTPAXTPCRB (2) XTCE007B0_ XTPAXFA XTSR2P5BB_ XTPR2P5BC XTPAXTPCRB (2) XTCE007B0_ XTPAXFA XTSR004BB_ XTPR004BC XTPAXTPCRB (2) XTCE007B0_ XTPAXFA XTSR6P3BB_ XTPR6P3BC XTPAXTPCRB (2) XTCE007B0_ XTPAXFA XTSR00BB_ XTPR00BC XTPAXTPCRB (2) XTCE009B0_ XTPAXFA XTSR02BB_ 8 2 XTPR02BC XTPAXTPCRB (2) XTCE02B0_ XTPAXFA XTSR Frame B MMP + Frame C Contactor XTSR06BC_ 0 6 XTPR06BC XTPAXTPCR (2) XTCE08C0 XTPAXFA XTSR020BC_ 6 20 XTPR020BC XTPAXTPCRC (2) XTCE025C0_ XTPAXFA XTSR025BC_ XTPR025BC XTPAXTPCRC (2) XTCE025C0_ XTPAXFA XTSR032BC_ XTPR032BC XTPAXTPCRC (2) XTCE032C0_ XTPAXFA XTSR Frame D MMP + Frame C Contactor XTSR06DC_ 0 6 XTPR06DC 2 (2) XTCE08C0 XTPAXFA XTSR025DC_ 6 25 XTPR025DC 2 (2) XTCE025C0_ XTPAXFA XTSR032DC_ XTPR032DC 2 (2) XTCE032C0_ XTPAXFA XTSR Frame D MMP + Frame D Contactor XTSR040DD_ XTPR040DC 3 (2) XTCE040D00_ XTPAXFA XTSR050DD_ XTPR050DC 3 (2) XTCE050D00_ XTPAXFA XTSR058DD_ XTPR058DC 3 (2) XTCE065D00_ XTPAXFA XTSR063DD_ XTPR063DC 3 (2) XTCE065D00_ XTPAXFA Notes Underscore (_) indicates magnetic coil suffix required. See Page V5-T The connection between the XTPR DC and the XTCE C_ contactor will be made with flexible wire and mounted to the DIN rail adapter plate (XTPAXTPCPD). 3 The reversing connection between the XTPR DC and the (2) XTCE C_ contactors will be accomplished by using the non-reversing combination connection kit (XTPAXTPCD), Frame D reversing link kit (XTCEXRLD), additional DIN rail adapter plate (XTPAXTPCPD) and DIN adapter connection element (XTPAXCNE). V5-T-206 Volume 5 Motor Control and Protection CA E April 203

51 . XTFC Non-Reversing Combination Motor Controllers Component Bill of Material Factory Assembled Manual Motor Protector + Contactor + Line Side Adapter Assembled FLA Adjustment Range/ Component s Combination Overload Release I r Line Side Manual Motor Combination Manual Motor Protector Motor Controller (Amps) Adapter Protector Connection Kit Contactor Auxiliary Contact XTFC Frame B MMP + Frame B Contactor XTFCP6BB_ XTPAXLSA XTPRP6BC XTPAXTPCB XTCE007B0_ XTPAXFA XTFCP25BB_ XTPAXLSA XTPRP25BC XTPAXTPCB XTCE007B0_ XTPAXFA XTFCP40BB_ XTPAXLSA XTPRP40BC XTPAXTPCB XTCE007B0_ XTPAXFA XTFCP63BB_ XTPAXLSA XTPRP63BC XTPAXTPCB XTCE007B0_ XTPAXFA XTFC00BB_ 0.63 XTPAXLS XTPR00BC XTPAXTPCB XTCE007B0_ XTPAXFA XTFCP6BB_.6 XTPAXLSA XTPRP6BC XTPAXTPCB XTCE007B0_ XTPAXFA XTFC2P5BB_ XTPAXLSA XTPR2P5BC XTPAXTPCB XTCE007B0_ XTPAXFA XTFC004BB_ XTPAXLSA XTPR004BC XTPAXTPCB XTCE007B0_ XTPAXFA XTFC6P3BB_ XTPAXLSA XTPR6P3BC XTPAXTPCB XTCE007B0_ XTPAXFA XTFC00BB_ XTPAXLSA XTPR00BC XTPAXTPCB XTCE009B0_ XTPAXFA XTFC02BB_ 8 2 XTPAXLSA XTPR02BC XTPAXTPCB XTCE02B0_ XTPAXFA XTFC06BB_ 0 6 XTPAXLSA XTPR06BC XTPAXTPCB XTCE05B0_ XTPAXFA XTFC Frame B MMP + Frame C Contactor XTFC06BC_ 0 6 XTPAXLSA XTPR06BC XTPAXTPCC XTCE08C0_ XTPAXFA XTFC020BC_ 6 20 XTPAXLSA XTPR020BC XTPAXTPCC XTCE025C0_ XTPAXFA XTFC025BC_ XTPAXLSA XTPR025BC XTPAXTPCC XTCE025C0_ XTPAXFA XTFC032BC_ XTPAXLSA XTPR032BC XTPAXTPCC XTCE032C0_ XTPAXFA XTFC Frame D MMP + Frame C Contactor XTFC06DC_ 0 6 XTPAXLSAD XTPR06DC 2 XTCE08C0_ XTPAXFA XTFC025DC_ 6 25 XTPAXLSAD XTPR025DC 2 XTCE025C0_ XTPAXFA XTFC032DC_ XTPAXLSAD XTPR032DC 2 XTCE032C0_ XTPAXFA XTFC Frame D MMP + Frame D Contactor XTFC040DD_ XTPAXLSAD XTPR040DC XTPAXTPCD 3 XTCE040D00_ XTPAXFA XTFC050DD_ XTPAXLSAD XTPR050DC XTPAXTPCD 3 XTCE050D00_ XTPAXFA XTFC058DD_ XTPAXLSAD XTPR058DC XTPAXTPCD 3 XTCE065D00_ XTPAXFA XTFC063DD_ XTPAXLSAD XTPR063DC XTPAXTPCD 3 XTCE065D00_ XTPAXFA Notes Underscore (_) indicates magnetic coil suffix required. See Page V5-T The connection between the XTPR DC and the XTCE C_ contactor will be made with flexible wire and mounted to the DIN rail adapter plate (XTPAXTPCPD). 3 The reversing connection between the XTPR DC and the (2) XTCE C_ contactors will be accomplished by using the non-reversing combination connection kit (XTPAXTPCD), Frame D reversing link kit (XTCEXRLD), additional DIN rail adapter plate (XTPAXTPCPD) and DIN adapter connection element (XTPAXCNE). Volume 5 Motor Control and Protection CA E April V5-T-207

52 . XTFR Reversing Combination Motor Controllers Component Bill of Material Factory Assembled Manual Motor Protector + Contactor + Line Side Adapter FLA Adjustment Range/ Component s Assembled Combination Overload Release I r Line Side Manual Motor Combination Manual Motor Protector Motor Controller (Amps) Adapter Protector Connection Kit Contactor Auxiliary Contact XTFR Frame B MMP + Frame B Contactor XTFRP6BB_ XTPAXLSA XTPRP6BC XTPAXTPCRB (2) XTCE007B0_ XTPAXFA XTFRP25BB_ XTPAXLSA XTPRP25BC XTPAXTPCRB (2) XTCE007B0_ XTPAXFA XTFRP40BB_ XTPAXLSA XTPRP40BC XTPAXTPCRB (2) XTCE007B0_ XTPAXFA XTFRP63BB_ XTPAXLSA XTPRP63BC XTPAXTPCRB (2) XTCE007B0_ XTPAXFA XTFR00BB_ 0.63 XTPAXLSA XTPR00BC XTPAXTPCRB (2) XTCE007B0_ XTPAXFA XTFRP6BB_.6 XTPAXLSA XTPRP6BC XTPAXTPCRB (2) XTCE007B0_ XTPAXFA XTFR2P5BB_ XTPAXLSA XTPR2P5BC XTPAXTPCRB (2) XTCE007B0_ XTPAXFA XTFR004BB_ XTPAXLSA XTPR004BC XTPAXTPCRB (2) XTCE007B0_ XTPAXFA XTFR6P3BB_ XTPAXLSA XTPR6P3BC XTPAXTPCRB (2) XTCE007B0_ XTPAXFA XTFR00BB_ XTPAXLSA XTPR00BC XTPAXTPCRB (2) XTCE009B0_ XTPAXFA XTFR02BB_ 8 2 XTPAXLSA XTPR02BC XTPAXTPCRB (2) XTCE02B0_ XTPAXFA XTFR Frame B MMP + Frame C Contactor XTFR06BC_ 0 6 XTPAXLSA XTPR06BC XTPAXTPCRC (2) XTCE08C0_ XTPAXFA XTFR020BC_ 6 20 XTPAXLSA XTPR020BC XTPAXTPCRC (2) XTCE025C0_ XTPAXFA XTFR025BC_ XTPAXLSA XTPR025BC XTPAXTPCRC (2) XTCE025C0_ XTPAXFA XTFR032BC_ XTPAXLSA XTPR032BC XTPAXTPCRC (2) XTCE032C0_ XTPAXFA XTFR Frame D MMP + Frame C Contactor XTFR06DC_ 0 6 XTPAXLSAD XTPR06DC 2 (2) XTCE08C0_ XTPAXFA XTFR025DC_ 6 25 XTPAXLSAD XTPR025DC 2 (2) XTCE025C0_ XTPAXFA XTFR032DC_ XTPAXLSAD XTPR032DC 2 (2) XTCE032C0_ XTPAXFA XTFR Frame D MMP + Frame D Contactor XTFR040DD_ XTPAXLSAD XTPR040DC 3 (2) XTCE040D00_ XTPAXFA XTFR050DD_ XTPAXLSAD XTPR050DC 3 (2) XTCE050D00_ XTPAXFA XTFR058DD_ XTPAXLSAD XTPR058DC 3 (2) XTCE065D00_ XTPAXFA XTFR063DD_ XTPAXLSAD XTPR063DC 3 (2) XTCE065D00_ XTPAXFA Notes Underscore (_) indicates magnetic coil suffix required. See Page V5-T The connection between the XTPR DC and the XTCE C_ contactor will be made with flexible wire and mounted to the DIN rail adapter plate (XTPAXTPCPD). 3 The reversing connection between the XTPR DC and the (2) XTCE C_ contactors will be accomplished by using the non-reversing combination connection kit (XTPAXTPCD), Frame D reversing link kit (XTCEXRLD), additional DIN rail adapter plate (XTPAXTPCPD) and DIN adapter connection element (XTPAXCNE). V5-T-208 Volume 5 Motor Control and Protection CA E April 203

53 . Manual Motor Controllers Short-Circuit Ratings for UL/CSA Group Installations XTSC and XTSR Manual Motor Controllers (MMC) Group Installation, UL/CSA Assembled Controller FLA Adjustment Max. rms Symmetrical Short-Circuit Range/Overload Short-Circuit Ratings (ka/ka with Current Limiter) Release Release Non-Reversing Reversing I r (Amps) I rm (Amps) 240V 480V 600V Note Underscore (_) indicates magnetic coil suffix required. See Page V5-T-202. Maximum Upstream Protective Device (A/A with Current Limiter) Maximum Fuse 600V XTSC and XTSR Frame B MMP + Frame B Contactor XTSCP6BB_ XTSRP6BB_ XTSCP25BB_ XTSRP25BB_ XTSCP40BB_ XTSRP40BB_ XTSCP63BB_ XTSRP63BB_ XTSC00BB_ XTSR00BB_ XTSCP6BB_ XTSRP6BB_ XTSC2P5BB_ XTSR2P5BB_ XTSC004BB_ XTSR004BB_ XTSC6P3BB_ XTSR6P3BB_ XTSC00BB_ XTSR00BB_ /600 25/600 XTSC02BB_ XTSR02BB_ /50 0/50 0/50 50/600 25/600 XTSC06BB_ /50 0/50 0/50 50/600 25/600 XTSC and XTSR Frame B MMP + Frame C Contactor XTSC06BC_ XTSR06BC_ /50 0/50 0/50 50/600 25/600 XTSC020BC_ XTSR020BC_ /8 0/8 0/8 50/600 25/600 XTSC025BC_ XTSR025BC_ /8 0/8 0/8 50/600 25/600 XTSC032BC_ XTSR032BC_ /8 5/8 5/8 50/600 25/600 XTSC and XTSR Frame D MMP + Frame C Contactor XTSC06DC_ XTSR06DC_ XTSC025DC_ XTSR025DC_ XTSC032DC_ XTSR032DC_ XTSC and XTSR Frame D MMP + Frame D Contactor XTSC040DD_ XTSR040DD_ XTSC050DD_ XTSR050DD_ XTSC058DD XTSR058DD_ XTSC063DD_ XTSR063DD_ Maximum Circuit Breaker 600V Volume 5 Motor Control and Protection CA E April V5-T-209

54 . Combination Motor Controllers Short-Circuit Ratings for UL 508 Type F Application XTFC and XTFR Combination Motor Controllers (CMC), UL 508 Type F UL 508 Type F Application Assembled Controller FLA Adjustment Max. rms Symmetrical Short-Circuit Range/Overload Short-Circuit Ratings (ka) Release Release Non-Reversing Reversing I r (Amps) I rm (Amps) 240V 480/277V 600/347V Maximum Upstream Protective Device (A) 2 Maximum Fuse 600V Maximum Circuit Breaker 600V XTFC and XTFR Frame B MMP + Frame B Contactor XTFCP6BB_ XTFRP6BB_ Not required Not required XTFCP25BB_ XTFRP25BB_ Not required Not required XTFCP40BB_ XTFRP40BB_ Not required Not required XTFCP63BB_ XTFRP63BB_ Not required Not required XTFC00BB_ XTFR00BB_ Not required Not required XTFCP6BB_ XTFRP6BB_ Not required Not required XTFC2P5BB_ XTFR2P5BB_ Not required Not required XTFC004BB_ XTFR004BB_ Not required Not required XTFC6P3BB_ XTFR6P3BB_ Not required Not required XTFC00BB_ XTFR00BB_ Not required Not required XTFC02BB_ XTFR02BB_ Not required Not required XTFC06BB_ Not required Not required XTFC and XTFR Frame B MMP + Frame C Contactor XTFC06BC_ XTFR06BC_ Not required Not required XTFC020BC_ XTFR020BC_ Not required Not required XTFC025BC_ XTFR025BC_ Not required Not required XTFC032BC_ XTFR032BC_ Not required Not required XTFC and XTFR Frame D MMP + Frame C Contactor XTFC06DC_ XTFR06DC_ Not required Not required XTFC025DC_ XTFR025DC_ Not required Not required XTFC032DC_ XTFR032DC_ Not required Not required XTFC and XTFR Frame D MMP + Frame D Contactor XTFC040DD_ XTFR040DD_ Not required Not required XTFC050DD_ XTFR050DD_ Not required Not required XTFC058DD_ XTFR058DD_ Not required Not required XTFC063DD_ XTFR063DD_ Not required Not required Notes Underscore (_) indicates magnetic coil suffix required. See Page V5-T For UL 508 Type F applications, the combination motor controller assembly does not require a dedicated upstream protective device in the panel, thus a maximum rating is not required. V5-T-20 Volume 5 Motor Control and Protection CA E April 203

55 . Dimensions Approximate Dimensions in mm [in] XTSC BB_ XTSR BB_ 95.7 [3.77] 32.5 [.28] To Terminals 95.3 [3.75] 78.5 [7.03] 32.5 [.28] To Terminals 83.4 [7.22] 45 [.77] 49.7 [.96] To Terminals 90.3 [3.55] 49.7 [.96] To Terminals Volume 5 Motor Control and Protection CA E April V5-T-2

56 . Approximate Dimensions in mm [in] XTSC BC_ Mounting Holes for M4 Screws or #8 Screws (4 Places) 57.5 [2.26] To Terminals 20.8 [8.30] Mounting [9.0] [9.28] 86.8 [3.42] To Terminals 9 [.35] 34 [.34] 24.3 [4.89] 45.2 [.78] XTSR BC_ Mounting Holes for M4 Screws or #8 Screws (4 Places) 57.5 [2.26] To Terminals 20.8 [8.30] Mounting [9.0] [9.27] 86.8 [3.42] To Terminals 9 [.35] 34 [.34] 45 [.77] 79 [3.] 5.3 [.2] 24.3 [4.89] 89.6 [3.53] V5-T-22 Volume 5 Motor Control and Protection CA E April 203

57 . Approximate Dimensions in mm [in] XTSC DD_ Mounting Holes for M5 Screws or #0 Screws (4 Places) 96 [7.72] 83.4 [3.28] To Terminals 266 [0.47] Mounting 284 [.8] 42.8 [5.62] To Coil Terminals 9 [.35] XTFC BB_ 43.4 [.7] Mounting 36.3 [.43] To Terminals 58.5 [6.24] 72. [6.78] To Optional Aux. Contacts 55 [2.7] [8.24] 49.7 [.96] To Terminals 95.7 [3.77] 45 [.77] Volume 5 Motor Control and Protection CA E April V5-T-23

58 . Approximate Dimensions in mm [in] XTFR BB_ 36.3 [.43] To Terminals 24.2 [8.43] 49.7 [.96] To Terminals 95.3 [3.75] 90.3 [3.55] XTFC BC_ 34 [.34] Mounting 6.3 [2.4] To Terminals Mounting Holes for M4 Screws or #8 Screws (4 Places) 20.8 [8.30] Mounting [9.0] [9.28] [0.50] 86.8 [3.42] To Terminals 9 [.35] 24.3 [4.89] 45.2 [.78] V5-T-24 Volume 5 Motor Control and Protection CA E April 203

59 . Approximate Dimensions in mm [in] XTFR BC_ 6.3 [2.4] To Terminals Mounting Holes for M4 Screws or #8 Screws (8 Places) 20.8 [8.30] [9.0] [9.27] [0.49] 86.8 [3.42] To Terminals 9 [.35] 34 [.34] 45 [.77] 79 [3.] 5.3 [.2] 24.3 [4.89] 89.6 [3.53] XTFC DD_ Mounting Holes for M5 Screws or #0 Screws (4 Places) 86 [3.39] To Line Side Connector 266 [0.47] Mounting 284 [.8] 297 [.69] 42.8 [5.62] To Coil Terminals 9 [.35] 43.4 [.7] Mounting 58.5 [6.24] 72. [6.78] To Optional Aux. Contacts 55 [2.7] Volume 5 Motor Control and Protection CA E April V5-T-25

60 . XT Electronic Manual Motor Protector XT Electronic Manual Motor Protector Product Description Features and Benefits The XT Electronic Manual Advanced Trip Unit Motor Protector provides the same functionality as the XT thermal manual motor protector, but with an added level of flexibility and selectability. The XTPE incorporates electronic control technology to enable more options and larger dial setting ranges. The trip units are interchangeable, allowing users to exchange as needed using the same base. The reduced number of part numbers decreases bill of material complexity while reducing inventory demands. The XTPE electronic manual motor protector includes the following features: 4: max to min overcurrent dial setting range Selectable trip class (5, 0, 5, 20) Interchangeable trip units Three base units (2, 32 and 65A) Common accessories with the XTPR In addition to the selectability, the XTPE is also available with an advanced trip unit that can communicate system data and protector data thru SmartWire-DT. SmartWire-DT is an innovative cost effective connection technology that enables quick installation of control wiring to the starter through a single green cable. When on SmartWire-DT, the XTPE can communicate the following: Current Values Maximum phase current Overload warning Contents Description Relays and Timers Miniature Controls Contactors and Starters Thermal Overload Relays C440/XT Electronic Overload Relay Manual Motor Protectors Combination Motor Controllers XT Electronic Manual Motor Protector Selection Product Selection Accessories Technical Data and Specifications Dimensions Reference Data Diagnostics Data Overload fault Cause of trip (overcurrent or short circuit) Phase loss Trip via TEST Status Messages Control unit type Overload setting Time-lag Switching status XTPE Electronic MMP The XTPE Electronic MMP provides the selectability, control, and insight options that give panel builders and OEMs the solutions necessary to enhance motor control designs while reducing total costs. Page V5-T-3 V5-T-8 V5-T-35 V5-T-28 V5-T-4 V5-T-57 V5-T-93 V5-T-27 V5-T-28 V5-T-220 V5-T-226 V5-T-228 V5-T-229 Standards and Certifications CE approved UL Listed File No. E36332 UL 508 group motor and Type E IEC/EN CSA File 02528, Class V5-T-26 Volume 5 Motor Control and Protection CA E April 203

61 . Selection XT Manual Motor Protector Designation XT = XT line of IEC control XT Combinations Designation XT = XT line of IEC control Type FCE = Electronic combination motor controller Type PE = Electronic MMP XT PE 004 B CS Overload Release P2 = 0.3.2A 004 = 4A 02 = 3 2A 032 = 8 32A 065 = 6 65A Contactor Frame C = 45 mm MMP Frame B = 45 mm D = 55 mm XT FCE 004 B C CS A Overload Release P2 = 0.3.2A 004 = 4A 02 = 3 2A 032 = 8 32A MMP Frame B = 45 mm Trip Type CS = Standard CA = Advanced (SmartWire-DT) Trip Type CS = Selectable class 5, 0, 5, 20 CA = Selectable, advanced Coil Voltage A = 0V 50 Hz, 20V 60 Hz B = 220V 50 Hz, 240V 60 Hz F = 230V 50 Hz T = 24V 50/60 Hz TD = 24 Vdc Volume 5 Motor Control and Protection CA E April V5-T-27

62 . Product Selection XT Electronic Manual Motor Protector B Frame B Frame B Frame D Frame MMP Base Maximum Three-Phase hp Ratings 220V 380V Base Unit Maximum Amperage 200V 240V 480V 600V 230V 240V 400V 45V 440V 500V 600V 690V Type Number PKE2 XTPE02B PKE32 XTPE032B PKE65 XTPE065D MMP Trip Units Overload Release Setting Amp Range MMP Advanced Trip Units Used with SmartWire-DT IEC UL/CSA Maximum Motor kw Ratings Overload For Use with Maximum Three-Phase hp Ratings 220V 380V Trip Unit Release Setting Base Catalog 230V 400V 600V Amp Range Number 200V 240V 480V 600V 240V 45V 440V 500V 690V Type Number Note UL/CSA For Use with Base Catalog Number IEC Maximum Motor kw Ratings IEC UL/CSA Maximum Motor kw Ratings Maximum Three-Phase hp Ratings 220V 380V Trip Unit 200V 240V 480V 600V 230V 240V 400V 45V 440V 500V 600V 690V Type Number XTPE02B PKE-XTU-,2 XTPEXTP2B 4 XTPE02B PKE-XTU-4 XTPEXT004B 3 2 XTPE02B PKE-XTU-2 XTPEXT02B XTPE032B 8 32 XTPE032B PKE-XTU-32 XTPEXT032B 8 32 XTPE065D PKE-XTUW-32 XTPEXT032D 6 65 XTPE065D PKE-XTU-65 XTPEXT065D XTPE02B PKE-XTUA-,2 XTPEXTAP2B 4 XTPE02B PKE-XTUA-4 XTPEXTA004B 3 2 XTPE02B PKE-XTUA-2 XTPEXTA02B XTPE032B 8 32 XTPE032B PKE-XTUA-32 XTPEXTA032B 8 32 XTPE065D PKE-XTUWA-32 XTPEXTA032D 6 65 XTPE065D PKE-XTUA-65 XTPEXTA065D MMP Complete Assembly IEC UL/CSA Maximum Motor kw Ratings Overload Maximum Three-Phase hp Ratings 220V 380V Complete Manual Motor Protector Release Setting 230V 400V 600V Amp Range 200V 240V 480V 600V 240V 45V 440V 500V 690V Type Number PKE2/XTU-,2 XTPEP2BCS PKE2/XTU-4 XTPE004BCS PKE2/XTU-2 XTPE02BCS PKE32/XTU-32 XTPE032BCS PKE65/XTUW-32 XTPE032DCS PKE65/XTU-65 XTPE065DCS In this range, calculate motor rating according to rated current. Specified values to NEC (A) (). V5-T-28 Volume 5 Motor Control and Protection CA E April 203

63 . B Frame MMP Used with SmartWire-DT Complete Assembly IEC UL/CSA Maximum Motor kw Ratings Overload Maximum Motor hp Ratings 220V 380V Complete Manual Motor Protector Release Setting 230V 400V 600V Amp Range 200V 230V 460V 575V 240V 45V 440V 500V 690V Type Number PKE2/XTUA-,2 XTPEP2BCA PKE2/XTUA-4 XTPE004BCA PKE2/XTUA-2 XTPE02BCA PKE32/XTUA-32 XTPE032BCA UL 508 Type E XT Electronic Combination Motor Controllers Complete Assembly Including Trip Unit B Frame B Frame Electronic MMP with C Frame Contactor UL/CSA Overload Maximum Three-Phase hp Ratings Maximum Single-Phase hp Ratings Release Setting 380Y/ 480Y/ 600Y/ Amp Range 200V 240V 45V 277V 347V 5V 200V 240V Notes In this range, calculate motor rating according to rated current. Specified values to NEC (A) (). 2 Complete the catalog number by replacing the underscore (_) with the coil suffix from Page V5-T SCCR: 4 ka, 600 Vac 4 SCCR: 8 ka, 480 Vac Standard With SmartWire-DT XTFCEP2BCCS_ 3 XTFCEP2BCCATD XTFCE004BCCS_ 4 XTFCE004BCCATD XTFCE02BCCS_ 4 XTFCE02BCCATD XTFCE032BCCS_ 4 XTFCE032BCCATD 4 Volume 5 Motor Control and Protection CA E April V5-T-29

64 . Accessories Auxiliary Contacts XTPAXSA_ XTPAXFA Side-Mount Auxiliary Contacts Contact Configuration Contact Sequence Can be fitted on the right side of manual motor protectors (XTPB, XTPR, XTPM) and manual transformer protectors (XTPT) and can be combined with XTPAXSATR_ and XTPAXFA_ trip indicating auxiliary contact. Front-Mount Auxiliary Contacts Contact Configuration Contact Sequence Can be fitted to manual motor protectors (XTPB, XTPR, XTPM) and manual transformer protectors (XTPT). 45 mm (XTPR B and XTPB) or 55 mm (XTPR D) widths of manual motor protectors remain unchanged. Note Orders must be placed in multiples of package quantity listed. Pkg. Qty. Screw Terminal NO-NC XTPAXSA L L2 L3 XTPAXSA.4.22 NO-2NC XTPAXSA2 L L2 L3 XTPAXSA NO-NC XTPAXSA2 L L2 L3 XTPAXSA Pkg. Qty. Screw Terminal NO-NC XTPAXFA L L2 L3 XTPAXFA V5-T-220 Volume 5 Motor Control and Protection CA E April 203

65 . XTPAXSATR_ Side-Mount Trip Indicating Auxiliary Contacts Contact Configuration Contact Sequence Can be fitted on the right side of manual motor protectors. Can be combined with standard auxiliary contacts. Trip indication: A. General trip indication (overload) B. Short-circuit trip. Local short-circuit indication by red indicator, manually resettable. Note Orders must be placed in multiples of package quantity listed. Pkg. Qty. For Use with 2 x NO + 2 XTPE XTPAXSATR20 On/Off LL2L3 + > Trip + LL2L3 + > x NC + 2 XTPE XTPAXSATR02 On/Off LL2L3 + > Trip + LL2L3 + > Volume 5 Motor Control and Protection CA E April V5-T-22

66 . Additional Accessories XTPAXSR_ Contact Sequence C C2 Shunt Release Pkg. Qty. Screw Terminal 2 XTPAXSR24V50H 2 XTPAXSR48V50H 2 XTPAXSR0V50H 2 XTPAXSR20V60H 2 XTPAXSR208V60H 2 XTPAXSR220V50H 2 XTPAXSR230V50H 2 XTPAXSR240V50H 2 XTPAXSR240V60H 2 XTPAXSR380V50H 2 XTPAXSR400V50H 2 XTPAXSR45V50H 2 XTPAXSR440V60H 2 XTPAXSR480V60H 2 XTPAXSR24VDC 2 XTPAXSR48VDC 2 XTPAXSR60VDC 2 XTPAXSR0VDC 2 XTPAXSR25VDC 2 XTPAXSR220VDC 2 XTPAXSR250VDC Can be used to trip the manual motor protector from a remote location. Can be fitted on the left side of manual motor protectors. Cannot be combined with the XTPAXUVR. DC: Intermittent operation 5 sec. XTPAXUVR_ Contact Sequence D U D2 Undervoltage Release Pkg. Qty. Can be used to trip the manual motor protector from a remote location. Can be fitted on left side manual motor protectors. Cannot be combined with XTPAXSR. When combined with a circuit breaker, it can be used as emergency-stop device to IEC/EN Note Orders must be placed in multiples of package quantity listed. Screw Terminal 2 XTPAXUVR24V50H 2 XTPAXUVR24V60H 2 XTPAXUVR48V50H 2 XTPAXUVR60V50H 2 XTPAXUVR0V50H 2 XTPAXUVR20V60H 2 XTPAXUVR208V60H 2 XTPAXUVR220V50H 2 XTPAXUVR230V50H 2 XTPAXUVR240V50H 2 XTPAXUVR240V60H 2 XTPAXUVR380V50H 2 XTPAXUVR400V50H 2 XTPAXUVR45V50H 2 XTPAXUVR440V60H 2 XTPAXUVR480V60H 2 XTPAXUVR600V60H V5-T-222 Volume 5 Motor Control and Protection CA E April 203

67 . XTPAXRHM_ XTPAXUTS XTPAXIT IP65 Rotary Handle Mechanism 23 Description Three-Phase Commoning Links 7 For parallel power feed to several manual motor protectors on terminals, 3 and 5. Shroud for Unused Terminals of Three-Phase Commoning Links Pkg. For Use with Description Qty. 4 Incoming Terminals for Three-Phase Commoning Link 8 Enclosure Rating Pkg. Qty. 4 Complete Kits Includes Handle, Shaft and Required Hardware Rotary handle mechanism black 5 IP65 XTPEXRHMB Rotary handle mechanism red/yellow 6 NEMA 2 UL/CSA 4X XTPEXRHMRY Rotary handle mechanism black rotated 90 from vertical 5 XTPEXRHM90B Rotary handle mechanism red/yellow rotated 90 from vertical 6 XTPEXRHM90RY For Use with MMP with no side-mounted auxiliaries or voltage releases Each MMP with one auxiliary contact or trip-indicating auxiliary contact fitted on the right Each MMP with an auxiliary contact and trip-indicating auxiliary contact mounted on the right or a voltage release mounted on the left. Frame B XTPE For Use with Qty. MMP Length of Link (mm) Unit Width (mm) Pkg. Qty XTPAXCLKA XTPAXCLKA XTPAXCLKA XTPAXCLKA XTPAXCLKB XTPAXCLKB XTPAXCLKB XTPAXCLKB XTPAXCLKC2 To cover unused terminals on three-phase commoning link. Protected against direct contact. Pkg. Qty. 4 Frame B XTPE 5 XTPAXIT 20 XTPAXUTS Notes Plug-in connection shafts, XTPAXRHMSFT_ can be cut to desired length for mounting depths of mm. Carrier with extension shaft included. 2 With ON/OFF switch position and + (tripped), lockable with 3 padlocks, 4 8 mm hasp. Can be locked in the OFF position, if required. 3 Rotary handle mechanisms ship with door interlock disabled. See instruction publication with product for how to enable door interlock. 4 Orders must be placed in multiples of package quantity listed. 5 For use on main switches to IEC/EN For use on main switches with emergency-stop function to IEC/EN Protected against accidental contact. Frame B short-circuit proof Ue = 690V, I u = 63A. Frame B links can be combined by rotating mounting. 8 For three-phase commoning link, protected against accidental contact, Ue = 690V, I u = 63A; For conductor cross-sections: mm2 stranded; mm2 flexible with ferrules, AWG 4-6. Volume 5 Motor Control and Protection CA E April V5-T-223

68 . Combination Connection Kits XTPAXTPCB XTPAXTPC_ XTPAXTPCRB XTPAXTPCRC Non-Reversing Starters For Use with Reversing Starters Note Description/Comprised of Orders must be placed in multiples of package quantity listed. Std. Pack XTPE B + XTCE B Mechanical connection element for XTPR B and contactor XTPAXTPCB Main current wiring between XTPR B and contactor in toolless plug connection Use contactor auxiliary switch XTCEXFAT_. Control cable guidance: max. six cables up to 2.5 mm 2 external diameter or four cables up to 3.5 mm 2 external diameter. XTPR B + XTCE C For Use with DIN rail adapter plate Main current wiring between XTPR and contactor Description/Comprised of XTPAXTPCC Std. Pack XTPE B + XTCE B0_ Mechanical connection element for XTPR B and contactor XTPAXTPCRB Reversing starter main current wiring in toolless plug connection Control cables for electrical interlocking in toolless plug connection: KM: A K2M: 2 KM: 2 K2M: A KM: A2 K2M: A2 Cable guidance Use contactor auxiliary switch XTCEXFAT_. Control cable guidance: max. six cables up to 2.5 mm 2 external diameter or four cables up to 3.5 mm 2 external diameter. XTPE B + XTCE C DIN rail adapter plate XTPAXTPCRC Reversing starter main current wiring V5-T-224 Volume 5 Motor Control and Protection CA E April 203

69 . XTPAXECM_ XTPAXTPCPB PKE-SWD-32 Electrical Connection Module For Use with DIN Rail Adapter Plates Note Description/Comprised of Orders must be placed in multiples of package quantity listed. Std. Pack XTPE B + XTCE C Main current wiring between XTPR B and contactor 5 XTPAXECMC For Use with XTPAXTPCB XTPAXTPCRB XTPE B + XTCE B or C Description/Comprised of Std. Pack 45 mm wide adapter plate with one DIN rail 4 XTPAXTPCPB Connection element for side-by-side positioning of further plates SmartWire-DT communication link PKE-SWD-32 Volume 5 Motor Control and Protection CA E April V5-T-225

70 . Technical Data and Specifications XT Electronic Manual Motor Controllers Description Specification XTPE02B XTPE032B XTPE065D General Standards and regulations IEC/EN , VDE 0600, UL 508, CSA C 22.2 No. 4 Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC Ambient temperature Storage 40 to 80 C 40 to 80 C 40 to 80 C Open 25 to 55 C 25 to 55 C 25 to 55 C Enclosed 25 to 40 C 25 to 40 C 25 to 40 C Direction of incoming supply Any Any Any Degree of protection Device IP20 IP20 IP20 Terminals IP00 IP00 IP00 Touch protection Mechanical shock resistance half-sinusoidal shock, 25g 25g 25g 0 ms to IEC Altitude Max. 2000m Max. 2000m Max. 2000m Conductor Cross-Sections Screw terminals Solid x ( 6) mm 2 x ( 6) mm 2 x (0.75 6) mm 2 2 x ( 6) mm 2 2 x ( 6) mm 2 2 x (0.75 6) mm 2 Stranded with ferrule x ( 6) mm 2 x ( 6) mm 2 x ( ) mm 2 to DIN x ( 6) mm 2 2 x ( 6) mm 2 2 x ( ) mm 2 Solid or stranded 8 0 AWG 8 0 AWG 4 2 AWG Screw Terminal Tightening Torque Main conductor.7 Nm.7 Nm 3.3 Nm Auxiliary conductor Nm Nm Nm Main Circuit Rated impulse withstand voltage U mp 6,000 Vac 6,000 Vac 6,000 Vac Overvoltage category/pollution degree III/3 III/3 III/3 Rated operational voltage U e 690V 690V 690V Rated uninterrupted current = rated output current I u = I e 2A 32A 65A Rated frequency Hz Hz Hz Current heating losses (three-pole at operating 6W 6W 6W temperature) Lifespan, mechanical Operations 0.05 x x x 0 6 Lifespan, electrical (AC-3 at 400V) Operations 0.05 x x x 0 6 Maximum operating frequency Operations/h Short-Circuit Rating Motor switching capacity AC AC-3 up to 690V 2A 32A 65A Trip Unit Temperature compensation to IEC/EN 60947, VDE to 40 C 5 to 40 C 5 to 40 C Operating range 25 to 55 C 25 to 55 C 25 to 55 C Temperature compensation residual error for T >40 C <0.%/K <0.%/K <0.%/K Overload release setting range 0.25 xl u 0.25 xl u 0.25 xl u Fixed short-circuit trip setting 2 x l r (trip unit),4 x l u (base) 2 x l r (trip unit),4 x l u (base) 2 x l r (trip unit),4 x l u (base) Short circuit release tolerance ±20% ±20% ±20% Phase failure sensitivity Yes Yes Yes V5-T-226 Volume 5 Motor Control and Protection CA E April 203

71 Volume 5 Motor Control and Protection CA E April V5-T-227. Trip Characteristics XT Electronic Manual Motor Controllers XTPE

Features XT SC 012 B B A

Features XT SC 012 B B A Motor Control and Protection. XT IEC Manual and Combination Motor Controllers Selection XT IEC Manual and Combination Motor Controllers Manual and Combination Motor Controllers Design XT = XT IEC power

More information

Features XT SC 012 B B A

Features XT SC 012 B B A Motor Control and Protection. XT IEC Manual and Combination Motor Controllers Selection XT IEC Manual and Combination Motor Controllers Manual and Combination Motor Controllers Design XT = XT IEC power

More information

XT IEC Power Control Combination Motor Controllers

XT IEC Power Control Combination Motor Controllers 7 Product Family Overview May 007 Contents Description Page Standards and Certifications............. 7 Catalog Selection................ 76 Product Selection.......... 77 Accessories............... 7

More information

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Combination Motor Controllers. XT IEC Power Control

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Combination Motor Controllers. XT IEC Power Control IEC Contactors and Starters. Product Description Eaton s XT IEC open nonreversing and reversing manual motor controllers combine a manual motor protector with an IEC contactor(s) to provide a complete

More information

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Combination Motor Controllers. XT IEC Power Control

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Combination Motor Controllers. XT IEC Power Control Product Description Eaton s XT IEC open nonreversing and reversing manual motor controllers combine a manual motor protector with an IEC contactor(s) to provide a complete motor protection solution by

More information

Bulletin 190 IEC Modular Starter System

Bulletin 190 IEC Modular Starter System Bulletin 90 Table of Contents Selection Guide Description Page Bulletin 90....................................... Accessories....................................... 7 Specifications.....................................

More information

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control . XT Family of Contactors Contactors and Starters Product Description The Eaton XT contactors and starters includes nonreversing and reversing contactors, overload relays and a variety of related accessories.

More information

110 Volt AC at 50 Hertz, 120 Volt AC at 60 Hertz. 20 Amp (UL Continuous), 7 Amp (AC-3), 22 Amp (AC-1)

110 Volt AC at 50 Hertz, 120 Volt AC at 60 Hertz. 20 Amp (UL Continuous), 7 Amp (AC-3), 22 Amp (AC-1) 80 South Street 7596-726, TX Nacogdoches Phone: 96-569-79 Fax: 96-560-685 XTCE007B0A PH FVNR 7A IEC Contactor Eaton Corp Catalog Number XTCE007B0A Manufacturer Eaton Corp Description Magnetic Contactor,

More information

Series CT7N Bimetallic Overload Relays

Series CT7N Bimetallic Overload Relays Series CT7N imetallic Overload Relays Choose CT7N overloads in DC applications and when monitoring Variable Frequency Drives Sprecher + Schuh has always paid particular attention to the subject of motor

More information

Minicontactorrelay,2NO/2NC,DCoperated

Minicontactorrelay,2NO/2NC,DCoperated Minicontactorrelay,2NO/2NC,DCoperated Partno. DILER-22-G(24VDC) Articleno. 010042 CatalogNo. XTRM10A22TD Deliveryprogramme Product range DILER Mini-contactors Application Contactor relays Connection technique

More information

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC Deliveryprogramme Contactorrelay,3N/O+1N/C,AC Partno. DILER-31(230V50HZ,240V60HZ) Articleno. 051768 CatalogNo. XTRM10A31F Product range DILER Mini-contactors Application Contactor relays Description with

More information

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control IEC Contactors and Starters. XT Family of Contactors Contactors and Starters Product Description The Eaton XT contactors and starters includes nonreversing and reversing contactors, overload relays and

More information

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100 DATASHEET - NZMH2-A100 Circuit-breaker, 3p, 100A Part no. NZMH2-A100 Catalog No. 259099 Similar to illustration Delivery program Product range Circuit-breaker Protective function System and cable protection

More information

Type: DILM25 10(24V50HZ) Article No.:

Type: DILM25 10(24V50HZ) Article No.: Type: DILM25 10(24V50HZ) Article No.: 277119 Ordering information Rated operational current AC 3 400 V I e A 25 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors,

More information

Type: NZMN1 A100 Article No.: Sales text Circuit breaker3p systems/cable prot. Ordering information Number of poles

Type: NZMN1 A100 Article No.: Sales text Circuit breaker3p systems/cable prot. Ordering information Number of poles Type: NZMN1 A100 Article No.: 259085 Sales text Circuit breaker3p systems/cable prot. Ordering information Number of poles Description Rated current = rated uninterrupted current Setting range 3 pole I

More information

Description Set value in neutral conductor is synchronous with set value Ir of main pole. R.m.s. value measurement and thermal memory CSA 100

Description Set value in neutral conductor is synchronous with set value Ir of main pole. R.m.s. value measurement and thermal memory CSA 100 DATASHEET - NZMN3-4-AE400 Circuit-breaker, 4p, 400A Part no. NZMN3-4-AE400 Catalog No. 265891 Similar to illustration EL-Nummer (Norway) 0004358857 Delivery program Product range Circuit-breaker Protective

More information

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit DATASHEET - S811+N66N3S Delivery program Soft starter, 66 A, 200-600 V AC, Us= 24 V DC, with control unit, Frame size N Part no. S811+N66N3S Catalog No. 168978 Eaton Catalog No. S811PLUSN66N3S EL-Nummer

More information

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A Deliveryprogramme Circuitbreak.3pselect.protection Partno. Articleno. 265777 NZMH4-VE1600 Product range Circuit-breaker Protective function Systems, cable, selectivity and generator protection Standard/Approval

More information

Type: DILM12 10(24VDC) Article No.:

Type: DILM12 10(24VDC) Article No.: Type: DILM12 10(24VDC) Article No.: 276845 Ordering information Rated operational current AC 3 400 V I e A 12 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors,

More information

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control XT Family of Contactors Contactors and Starters Product Description The Eaton XT contactors and starters includes nonreversing and reversing contactors, overload relays and a variety of related accessories.

More information

I r A I i = I n x. Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

I r A I i = I n x. Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100 Deliveryprogramme Circuitbr.,3pmotorprotection Partno. Articleno. 265784 NZMN4-ME875 Product range Circuit-breaker Protective function Motor protection Standard/Approval IEC Installation type Fixed Release

More information

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A DATASHEET - NZMN3-VE630 Circuit-breaker, 3p, 630A Part no. NZMN3-VE630 Catalog No. 259133 EL-Nummer (Norway) 0004358791 Similar to illustration Delivery program Product range Circuit-breaker Protective

More information

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100 DATASHEET - NZMC1-A160 Circuit-breaker, 3p, 160A Part no. NZMC1-A160 Catalog No. 283296 Similar to illustration Delivery program Product range Circuit-breaker Protective function System and cable protection

More information

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control . XT Family of Contactors Contactors and Starters Product Description The Eaton XT contactors and starters includes nonreversing and reversing contactors, overload relays and a variety of related accessories.

More information

High performance circuit breakers

High performance circuit breakers Series High performance Description The high performance MCB offers a compact solution to circuit protection. The devices are DIN rail mounted. The is available with application-specific trip characteristics

More information

Description Set value in neutral conductor is synchronous with set value Ir of main pole. CSA 100. conductor. I r A 50-63

Description Set value in neutral conductor is synchronous with set value Ir of main pole. CSA 100. conductor. I r A 50-63 Circuit-breaker,4p,63A Partno. NZMH1-4-A63 Articleno. 284426 Similar to illustration Deliveryprogram Product range Circuit-breaker Protective function System and cable protection Standard/Approval IEC

More information

Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100 Circuit-breaker3psystems/cableprot. Partno. NZMB2-A250 Articleno. 259090 Deliveryprogramme Range Circuit-breaker Protective function System and cable protection Standard/Approval IEC Installation type

More information

AS09..S 3-pole Contactors - Spring Terminals

AS09..S 3-pole Contactors - Spring Terminals 4 kw 5 hp AS09..S 3-pole Contactors - Spring AC Operated Description - 3-pole contactors with spring terminals, - N.C. or N.O. built-in auxiliary contact, - Rail-mounted, no tools required, - Additional

More information

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100 Circuit-breaker,3p,160A Partno. NZMN2-M160 CatalogNo. 265724 Similar to illustration Deliveryprogram Product range Circuit-breaker Protective function Motor protection Standard/Approval IEC Installation

More information

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories PBC series IEC-Type Contactors & Accessories 9-80 Amp AC-3, 25-125 Amp AC-1 AC Coils File E38802 (PBC) RoHS Ready Users should thoroughly review the technical data before selecting a product part number.

More information

I r A Protection against direct contact Finger and back-of-hand proof to VDE 0106 part 100

I r A Protection against direct contact Finger and back-of-hand proof to VDE 0106 part 100 Circuit-breaker,3p,400A Partno. LZMC3-A400-I Articleno. 111955 Similar to illustration Deliveryprogramme Product range Circuit-breaker Protective function System and cable protection Standard/Approval

More information

TeSys circuit-breakers

TeSys circuit-breakers Thermal-magnetic motor circuit-breakers type GV2-ME GV2-ME with pushbutton control and screw clamp terminals (1) Standard power ratings Setting Magnetic Reference Weight of -phase motors range tripping

More information

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control . XT Family of Contactors Contactors and Starters Product Description The Eaton XT contactors and starters includes nonreversing and reversing contactors, overload relays and a variety of related accessories.

More information

1.1. Contactors and Starters... Contents Description Relays and Timers Catalog Number Selection... Product Selection...

1.1. Contactors and Starters... Contents Description Relays and Timers Catalog Number Selection... Product Selection... IEC ors and Starters. Contents Description Catalog Number Selection................ Product Selection....................... Accessories........................... Technical Data and Specifications..........

More information

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40 Characteristics Type of contactor LC- LC- LC- LC- LC-D & D09 D8 D2 D38 D40 D0 D9 LC-D0 DT20 & DT2 DT32 & DT40 Environment Rated insulation voltage (Ui) Conforming to IEC 947-4-, overvoltage category III,

More information

LC3D180AV7 TeSys D - star delta starter - 3 x 3P (3 NO) - 18 A V AC coil

LC3D180AV7 TeSys D - star delta starter - 3 x 3P (3 NO) - 18 A V AC coil Characteristics TeSys D - star delta starter - 3 x 3P (3 NO) - 18 A - 400 V AC coil Main Range Product name Product or component type Device short name Contactor application Utilisation category Device

More information

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control IEC Contactors and Starters. XT Family of Contactors Contactors and Starters Product Description The Eaton XT contactors and starters includes nonreversing and reversing contactors, overload relays and

More information

LC3D115M7 TeSys D - star delta starter - 3 x 3P (3 NO) A V AC coil

LC3D115M7 TeSys D - star delta starter - 3 x 3P (3 NO) A V AC coil Characteristics TeSys D - star delta starter - 3 x 3P (3 NO) - 115 A - 220 V AC coil Main Range Product name Product or component type Device short name Contactor application Utilisation category Device

More information

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC Product datasheet Characteristics LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC Price* : 86.25 GBP Main Range Product name Product or component type Device short name Contactor application Utilisation category

More information

Manual Motor Starter Specifcations

Manual Motor Starter Specifcations Technical Data Manual Motor Starter Specifcations Bulletin 140A Topic Page Product Selection 2 Accessories 3 Specifications 6 Approximate Dimensions 13 Additional Resources These documents contain additional

More information

llen-bradley 194R-HM4-NFPA3

llen-bradley 194R-HM4-NFPA3 Technical Data Rotary Disconnect Switch Specifications Bulletin Number 194R Topic Page Product Line Overview 2 General Specifications Fuse Description 12 Approximate Dimensions 14 Additional Resources

More information

CT7N CT7 CT7K 4 6 CT TJ 4 6 CT7K TKK 6 10 CT TK 6 9 CT7K TKL

CT7N CT7 CT7K 4 6 CT TJ 4 6 CT7K TKK 6 10 CT TK 6 9 CT7K TKL Obsolete Overload Cross Reference Series CT7/CT7K to Cross Reference CT7 CT7K Directly Mounts to Contactor... Adjustment Catalog Adjustment Catalog Adjustment Catalog Code Code Range (A) Number Range (A)

More information

02/11/2015

02/11/2015 DIN Rail Mount 17.5 mm MUS/MUSF 80 AC/DC Part number 84872141 Control relays monitoring their own power supply - MUS : Over/undervoltage control Selectable latching (memory) function - MUSF : Over/undervoltage

More information

Product Information. Circuit Breaker BZM1(16 to 125 A) Circuit Breaker BZM2 (125 to 250A) Circuit Breaker BZM3 (250 to 400A)

Product Information. Circuit Breaker BZM1(16 to 125 A) Circuit Breaker BZM2 (125 to 250A) Circuit Breaker BZM3 (250 to 400A) Circuit Breakers BZM Product Information Circuit Breaker BZM1(16 to 125 A) Circuit Breaker BZM2 (125 to 250A) Circuit Breaker BZM3 (250 to 400A) BZM1 & BZM2 & BZM3 Accessories Optimum and Efficient Protection

More information

Data sheet. CI-TI TM Contactors and Motor Starters Contactors CI EI 520B1286

Data sheet. CI-TI TM Contactors and Motor Starters Contactors CI EI 520B1286 CI-TI TM Contactors and Motor Starters June 2002 DKACT.PD.C00.I2.02 520B1286 Introduction are intended for a.c. coil voltages and cover the power range 45-238 kw. The largest types, CI 170 EI-420 EI have

More information

LC3D80B7 TeSys D - star delta starter - 3 x 3P (3 NO) - 80 A - 24 V AC coil

LC3D80B7 TeSys D - star delta starter - 3 x 3P (3 NO) - 80 A - 24 V AC coil Characteristics TeSys D - star delta starter - 3 x 3P (3 NO) - 80 A - 24 V AC coil Price* : 4058.00 USD has not been replaced. Please contact your customer care center for more information. Main Range

More information

Contactors. Agency approvals. UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B

Contactors. Agency approvals. UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B Contactors Applications Type DP provide high performance with flexibility and reliability, designed to match numerous applications including: Motors Power supplies Food service equipment Compressors Business

More information

LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil Product datasheet Characteristics LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

Agency approvals UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B

Agency approvals UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B 11 Applications Type DP provide high performance with flexibility and reliability, designed to match numerous applications including: Motors Power supplies Food service equipment Compressors Business machines

More information

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil Product datasheet Characteristics LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil Product data sheet Characteristics LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

with handle LIMOGES Cedex 1. DESCRIPTION - USE 3. DIMENSIONS Symbol: Technology: Use:. For controlling a load remotely via a switch 2.

with handle LIMOGES Cedex 1. DESCRIPTION - USE 3. DIMENSIONS Symbol: Technology: Use:. For controlling a load remotely via a switch 2. 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 25A power contactors silent CONTENTS PAGES 1. Description, use... 1 2. Range... 1 3. Dimensions... 1 4. Positioning - Connection...

More information

Datasheet - SRB301LC 24VAC/DC

Datasheet - SRB301LC 24VAC/DC 25.02.2016-18:05:23h Datasheet - SRB301LC 24VAC/DC Guard door monitors and Safety control modules for Emergency Stop applications / General Purpose safety controllers (Series PROTECT SRB) / SRB301LC Preferred

More information

LC1D25G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A V AC coil

LC1D25G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A V AC coil Product data sheet Characteristics LC1D25G7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

LC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

LC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil Product data sheet Characteristics LC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

LC1D09B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V AC coil

LC1D09B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V AC coil Product data sheet Characteristics LC1D09B7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

Power Circuit of a UL508A Panel. Typical UL489 Application

Power Circuit of a UL508A Panel. Typical UL489 Application Typical UL489 Application Power Circuit of a UL508A Panel Disclaimer: This is an application example. Installation should be done by a qualified electrician under the guidance of UL specifications.. Altech

More information

AC1036. Definite Purpose Contactors

AC1036. Definite Purpose Contactors Definite Purpose Contactors Definite purpose contactors Definite purpose Contactors Applications Type DP contactors provide high performance with flexibility and reliability, designed to match numerous

More information

Data Sheet Definite Purpose Contactors Ex9CK Series

Data Sheet Definite Purpose Contactors Ex9CK Series Data Sheet Ex9CK Series Ex9CK40B0 Ex9CKA10 na.noarkelectric.com NOARK Ex9CK Series Features Ex9CK Series DP Contactors provide high performance with both flexibility and reliability. They are designed

More information

Ordering details. Approval. Classification

Ordering details. Approval. Classification Datasheet - SRB 301MC-24V Guard door monitors and Safety control modules for Emergency Stop applications / General Purpose safety controllers (Series PROTECT SRB) / SRB 301MC Fit for signal evaluation

More information

GV3P80 TeSys GV3P thermal-magn motor circuit breaker 70-80A EverLink

GV3P80 TeSys GV3P thermal-magn motor circuit breaker 70-80A EverLink Characteristics TeSys GV3P thermal-magn motor circuit breaker 70-80A EverLink Main Range Product name Device short name Product or component type Device application Trip unit technology Complementary Poles

More information

59.1. Motor Control and Protection. For Immediate Delivery or Tech Support call KMParts.com at (866) Product Overview.

59.1. Motor Control and Protection. For Immediate Delivery or Tech Support call KMParts.com at (866) Product Overview. .1 Motor Control and Protection Product Overview Selection Guide Description Definite Purpose XT IEC Miniature XT IEC Page 65 Page 69 Page 71 Type Definite purpose IEC IEC Approvals UL Recognized, CSA,

More information

LC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A V AC coil

LC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A V AC coil Product data sheet Characteristics LC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

Datasheet - SRB-E-201ST

Datasheet - SRB-E-201ST 27.04.2016-16:36:21h Datasheet - SRB-E-201ST Multi-function safety modules / SRB-E-201ST STOP 0 Function 1 oder 2-channel control Start button / Auto-start Monitoring two-hand control panels to EN 574

More information

LC1D50AFE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

LC1D50AFE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil Product data sheet Characteristics LC1D50AFE7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A - screw clamp terminals. Main.

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A - screw clamp terminals. Main. Product data sheet Characteristics GV2ME06 TeSys GV2-Circuit breaker-thermal-magnetic - 1...1.6 A - screw clamp terminals Main Range Product name Device short name Product or component type Device application

More information

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A -screw clamp terminals. Main.

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A -screw clamp terminals. Main. Product data sheet Characteristics GV2ME04 TeSys GV2-Circuit breaker-thermal-magnetic- 0.4...0.63 A -screw clamp terminals Main Range Product name Device short name Product or component type Device application

More information

LC1D150B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A - 24 V AC 50/60 Hz coil

LC1D150B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A - 24 V AC 50/60 Hz coil Product data sheet Characteristics LC1D150B7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

Series CDP2 Definite Purpose Contactors

Series CDP2 Definite Purpose Contactors Series CDP2 Definite Purpose Contactors High performance economical contactors for commercial applications up to 90 Sprecher + Schuh s Definite Purpose contactors are ideal for commercial applications

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker

Magnetic and Hydraulic-Magnetic Circuit Breaker Magnetic and Hydraulic-Magnetic Circuit Breaker 850-... Description Single, two, three and four pole magnetic and hydraulic-magnetic circuit breakers with trip-free-mechanism and toggle or rocker actuation.

More information

A V 50Hz / V 60Hz

A V 50Hz / V 60Hz A16-22-00 400-415V 50Hz / 415-440V 60Hz Products Low Voltage Products and Systems Control Products Contactors Block Contactors General Information Extended Product Type: A16-22-00 400-415V 50Hz / 415-440V

More information

GV2ME. Main. Device short name. Device application

GV2ME. Main. Device short name. Device application Product datasheet Characteristics GV2ME32 TeSys GV2-Circuit breaker-thermal-magnetic - 24...32 A - screw clamp terminals Main Range Product name Device short name Product or component type Device application

More information

.1 Product Overview The XT line of IEC power control offers starting and protection solutions ideal for control panels. Innovations in the design and

.1 Product Overview The XT line of IEC power control offers starting and protection solutions ideal for control panels. Innovations in the design and .1 Product Overview.............................................. Relays and Timers.............................................. Miniature Controls.............................................. Contactors

More information

ALLEN BRADLEY TIMING RELAY

ALLEN BRADLEY TIMING RELAY ALLEN BRADLEY TIMING RELAY Configuration Details Product: 700-HS12BA1 Description: 700-HS General Purpose Square Base Timing Relay, On Delay Timer, 1.0 to 180 seconds, DPDT, 120V AC 50/60Hz CONTROL RELAY

More information

GV2P05. Main. Device short name. Device application

GV2P05. Main. Device short name. Device application Product datasheet Characteristics GV2P05 Main Range Product name Device short name Product or component type Device application Trip unit technology TeSys TeSys GV2 GV2P Circuit breaker Motor Thermal-magnetic

More information

3.5. Control Relays and Timers. Contents. 9575H Series 3000 Type AA, AC and DC. General Purpose Relays Type AA

3.5. Control Relays and Timers. Contents. 9575H Series 3000 Type AA, AC and DC. General Purpose Relays Type AA .5 9575H Series 000 Relay Contents 9575H Series 000 Type AA, AC and DC Product Selection....................... Accessories............................ Technical Data and Specifications........... Dimensions............................

More information

Circuit-Breakers for Motor Protection Series 8523/8

Circuit-Breakers for Motor Protection Series 8523/8 > Accessories Auxiliary contacts 1 NC + 1 NO or 2 NC + 2 NO Undervoltage trip Shunt release > Switch operation with knop > Secure switching > Clear switch setting indicator > Different current setting

More information

DMX and 4000 air circuit breakers from 800 to 4000 A

DMX and 4000 air circuit breakers from 800 to 4000 A DMX 3 20 and 00 air circuit breakers from 800 to 00 NEW 286 56 + 288 02 (p. 4) 286 4 + 288 02 (p. 4) 28 56 + 288 02 (p. 4) Dimensions (p. to 53) Electrical characteristics (p. 54 to 5) ir circuit breakers

More information

Series CDP2 Definite Purpose Contactors

Series CDP2 Definite Purpose Contactors Series 2 Definite Purpose High performance economical contactors for commercial applications up to 90 Sprecher + Schuh s Definite Purpose contactors are ideal for commercial applications including air

More information

GV2ME086 TeSys GV2 - Circuit breaker - thermal-magnetic A - lugs-ring terminals

GV2ME086 TeSys GV2 - Circuit breaker - thermal-magnetic A - lugs-ring terminals Product data sheet Characteristics GV2ME086 TeSys GV2 - Circuit breaker - thermal-magnetic - 2.5...4 A - lugs-ring terminals Main Range Product name Device short name Device application Trip unit technology

More information

GV2ME083 TeSys GV2 - Circuit breaker - thermal-magnetic A - spring terminals

GV2ME083 TeSys GV2 - Circuit breaker - thermal-magnetic A - spring terminals Product datasheet Characteristics GV2ME083 TeSys GV2 - Circuit breaker - thermal-magnetic - 2.5...4 A - spring terminals Main Range Product name Device short name Product or component type Device application

More information

LC1D09M7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

LC1D09M7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil Bảng thông số sản phẩm Đặc diểm LC1D09M7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

Modular pulse operated latching relay 16 A

Modular pulse operated latching relay 16 A 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 Modular pulse operated latc / 05 / 07 / 08 / 10 / 11 / 12 / 14 / 16 / 20 and 927 00 / 49 CONTENTS PAGES 1. Description,

More information

GV2ME. Main. Device short name. Device application

GV2ME. Main. Device short name. Device application Product datasheet Characteristics GV2ME10 Main Range Product name Device short name Product or component type Device application Trip unit technology TeSys TeSys GV2 GV2ME Circuit breaker Motor Thermal-magnetic

More information

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A and 3DPT, 10 A UL Listed when used with proper Magnecraft s The 750R series octal base, plug-in relays offer clear or full-feature covers with multiple mounting options and accessories. 750R 750R Full-Feature

More information

Magnecraft Power Relays

Magnecraft Power Relays Description DPST-NO, 30 A; DPDT, 30 A (NO) / 3 A (NC) Description The series power relays offer a small package size and features Class F insulation for a maximum coil temperature of 55 C (3 F). These

More information

SINCE 1989 Quality Products, Prompt Services, Trustful Relationships www.kmindustrialcorp.com KM Industrial Corporation has established itself as a trusted supplier of Electrical, Machinery and Industry

More information

4/2 Introduction. 4/4 5SV RCCBs. 4/10 5SM3 RCCBs. 4/13 SIQUENCE 5SM3/5SU1 universal current-sensitive RCCBs, type B and type B+

4/2 Introduction. 4/4 5SV RCCBs. 4/10 5SM3 RCCBs. 4/13 SIQUENCE 5SM3/5SU1 universal current-sensitive RCCBs, type B and type B+ /2 Introduction / 5SV RCCBs /10 5SM3 RCCBs /13 SIQUENCE 5SM3/5SU1 universal -sensitive RCCBs, type B and type B+ /18 Additional components /22 5SM2 RC units /30 5SU1 RCBOs /38 5SM6 AFD units /1 5SM6 AFD

More information

and Refrigeration Institute). CAQ7 Capacitor Switching Contactors

and Refrigeration Institute). CAQ7 Capacitor Switching Contactors SSN9000 Series C7 Special Use designed and labeled for specific industrial applications Special Use Capacitor switching contactors HVC rated contactors NEM size labeled contactors Lighting contactors Hydraulic

More information

Movable Contacts Heavy duty silver cadmium oxide composition to resist welding and contact erosion for greater reliability

Movable Contacts Heavy duty silver cadmium oxide composition to resist welding and contact erosion for greater reliability Compare These Features Built-in Shock bsorber Reduces contact bounce for longer life. Coil Dust Cover Keeps dust and dirt away from magnet and coil area. Coil Class B (1300 C Insulation System) with wide

More information

Part-Turn Electric Multi-Turn Electric

Part-Turn Electric Multi-Turn Electric Optional 7 Handwheel Available NEMA 4 Enclosure Approvals MAR s Only (Canadian Standard Association) Enclosure NEMA 7 Enclosure Approvals MAR s Only (Canadian Standard Association) Class I, Divisions 1

More information

Catalogue numbers. PowerPact Multistandard. H-Frame, J-Frame unit-mount circuit breaker F-2. H-Frame, J-Frame circuit breaker accessories F-3

Catalogue numbers. PowerPact Multistandard. H-Frame, J-Frame unit-mount circuit breaker F-2. H-Frame, J-Frame circuit breaker accessories F-3 PowerPact Multistandard Catalogue numbers Functions and characteristics A-1 Installation recommendations B-1 Dimensions C-1 Wiring diagrams D-1 Additionals characteristics E-1 H-Frame, J-Frame unit-mount

More information

and Refrigeration Institute). Hydraulic Elevator Wye-Delta Contactors

and Refrigeration Institute). Hydraulic Elevator Wye-Delta Contactors C7 Series C7 Special Use designed and labeled for specific industrial applications The C7 line includes a number of contactors designed and labeled for specific industrial applications. In most cases,

More information

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O Characteristics motion servo drive - Lexium 23 - single phase 200...255 V - 1 kw - I/O Main Range of product Product or component type Device short name Complementary Format of the drive Network number

More information

DIN Power Module - Phase Adaptive

DIN Power Module - Phase Adaptive DIN Power Module ow Capacity Phase Adaptive DIN Power Module - Phase Adaptive 369849a 1 08.06.15 The Phase Adaptive Power Module family is a group of modular products for the control of lighting loads.

More information

SQM40/41 Actuators for air and gas dampers

SQM40/41 Actuators for air and gas dampers SQM40/41 Actuators for air and gas dampers Description SQM40/41 actuators are used for the positioning of flow control valves, butterfly valves, dampers or any application requiring rotary motion. The

More information