Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

Similar documents
Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

Programmable Room Thermostat With RF

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

RT505TX Programmable. The RT505TX can be used with any of these receivers RXBC605 RXWBC605 RXVBC605 RXST MHz

ST625TX Digital Room Thermostat

S-Series Digital Thermostat. Instruction Manual Model No ST620RF

1 Channel Multi-Purpose Programmer User Instructions

Radio Thermostat Clock

TDDFM14 OWNER S MANUAL

SCS318. User Instructions. SCS318 comprising of SCS317 7 Day Wireless Programmable Room Thermostat and SSR303 Receiver

CP027. User Operating Instructions. Two Channel Central Heating and Hot Water Programmer

ServicePlus S17R Series 2 User Operating Instructions

24 Hour & 7 Day Digital Immersion Heater Timeswitch Article

Comfort System T-32-P Universal Thermostat. Operation Manual

CP017 USER OPERATING INSTRUCTIONS. Single Channel Timeswitch

EN Wireless programmable thermostat

7 Day Digital Programmer

7 Day Digital Programmer 3 Channel Surface Mount

ChannelPlus H17XL Series 2 User Operating Instructions

7 Day Digital Time Switch

ULTRA-VANSTAT WIRELESS PROGRAMMABLE THERMOSTAT FOR CARAVANS

TRANSCENSION 6-CHANNEL DMX DIMMER PACK (order code: BOTE40) USER MANUAL

Digital Time Switch. Installation & Operating Instructions

Timer Modules. EL11 24 Hour Module EL17 7 Day Module. Installation & Operating Instructions

Electronic 7 User Operating Instructions

TP7001 Range Electronic 7 Day Programmable Room Thermostat. Danfoss Heating. Installation Guide

7 Day Digital Light Switch with Optional Dusk Start

Waterline Room Controller - Type WLCT3

LP20. Installation & User Guide. Dual Channel Programmer. Part number 25039DR

Timer Modules. MEU11 24 Hour Module, MEU17 7 Day Module (Without Housing)

USER & ENGINEER INSTRUCTION MANUAL

SINGLE ZONE CLIMATE ZONING SYSTEM. Technical Manual. Polyaire Pty Ltd

Lifestyle. Dual Channel Programmer. for heating AND hot water. Installation and User Instructions DUAL CHANNEL ISSA

Junior Max (JR Max ) Controller

Operation Guide 6022 ENGLISH

7 DAY DIGITAL LIGHTSWITCH WITH OPTIONAL DUSK START INSTALLATION & OPERATING. Cat No. ZV700 INSTRUCTIONS

ST9100C User Guide. Features

Inserting the batteries. Basic settings of the remote control

Slimline Digital Electric Radiator. Step by Step Programming Guide

XTM72 Exerciser Timer Module

All real signals have scale factor 10. Integer, Index and Logic has always scale factor 1.

Commander 384. w w w. p r o l i g h t. c o. u k U S E R M A N U A L

DRIVER 230 CPL 3 zone weekly programmer using power line carriers

Winmate Communication INC.

RAMMER INSTRUCTION MANUAL FITTING & OPERATING INSTRUCTIONS NEL PROGRAMMER. NSTAR Si MODELS

WiFi Controlled Fused Spur Time Switch

XTM72E & F Real-Time Clock Modules

24Hour/7Day Electronic Timeswitch

Digital Economy Seven Programmer

16 Amp Electronic 24 Hour/7 Day Time Controller

ACT 10 Digital Keypad Operating & Installation Instructions This manual is found at

ComfortChoice Touch Thermostat. Designed for ZigBee R Wireless Technology USER GUIDE

DPM 942-FPSI 4-20mA Loop Meter with Programmable Backlighting

1. Power supply 100, 110, 200, 220, 230 V AC (as designated), 50/60 Hz, single phase.

INSTRUCTION & INSTALLATION GUIDE

SMART Audio 400 classroom amplification system

Dragonfly Quad. User Manual V1.4. Order code: EQLED101

Battery Operated Controllers

Instruction Manual for Programmable Digital Timer

Ambient Weather WS-01 Intelligent Color Changing Temperature Night Light with Ambient Backlight User Manual

Ducasa Digital Programmer

Model IQ4-PC User Manual Revision Date:

Operating Instructions for Throttle Valves Using VRC Valve Positioner

SPX-5600 Series. Operations Manual. Suprex Reader Extender - RF Wireless Interface SPX-5600MAN. Page 1 of 20

SceneStyle2 User Guide

Instruction Manual

Ecomind Electricity Monitor Kit EM422EM-E-KBTS EM422EM-E-KMTS. Installation Instructions

OWNER S MANUAL MOTORIZED 7 WIDE TFT LCD COLOR MONITOR CNT-701

Room thermostat Instructions for Use. For the user. Instructions for Use. geotherm

TU-8A. 8 Channel Digital Timer Unit. Programming Guide

INSTRUCTION MANUAL DLC400BP DIGITIAL LIGHTING CONTROLLER FOR TECHNICAL SUPPORT: USA

Telemetry Receiver Installation Guide

DLP200M 2 Relay Module for Heating and Cooling Plants

1. General Information:

Integrated Remote Commander

MAKING MODERN LIVING POSSIBLE. TS715Si Electronic Single Channel Timeswitch with Service Interval Timer. Installation Guide.

FW/S Digital time switch 2CDG120039R0011 D GB F I E NL. Installation and operating instructions FW/S DCF antenna GPS antenna SELV MENU

External RF programmable room thermostat 411

ORDER CODE: EQLED65 USER MANUAL

EC7000, EC7004 and EC7005 Single Channel Electronic Time Controls

Spectra Batten (Order code: LEDJ95)

Fusion 120 Zoom. User Manual. Order code: EQLED068

STAGE SETTER-8. User Instructions. Elation Professional 4295 Charter Street Los Angeles Ca

TS-4000 Multifunction Thermostat Timer Switch User Manual

TORK DGU100/DGUM100 7 DAY DIGITAL TIME SWITCH INSTALLATION AND OPERATING INSTRUCTIONS READ INSTRUCTIONS CAREFULLY BEFORE SETTING UNIT

Operating instructions. Universal timer switch display

Operating Instructions. Room temperature controller with clock

VHF & UHF REMOTE RECEIVERS INSTALLATION AND PROGRAMMING INSTRUCTIONS MODEL NUMBERS TMP-5414 & TMP 5428

BT Diverse Repeater. User Guide

talento 800 Series 365-Day One, Two and Four Circuit Electronic Time Controls Functional Description

DLP600M 6+1 Relay Module for Heating and Cooling Plants

LCD Thermometer / Clock S No. 1253

GDB9 INSTRUCTION MANUAL DIGITAL TERRESTRIAL RECEIVER

APOLO DC B Electric Thermal Radiators

Overview: Specifications: Installation Instructions:

SAUTER flexotron RDT405 Manual

Installation & Programming Manual. Please read before using this timer.

Philips LightMaster. KNX Timeclock Installation and Operation Manual

Black & White Wireless Video Surveillance System

MRX1 1. Getting to know your MRX1 wireless controller

Transcription:

Instruction Manual TPSRF51 (957707) - BOSS TM Universal RF Programmable Room Thermostat (Wireless) (7 day, 5/2 day and 24 hour programme options) Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder. Please read this manual prior to installation or use. Always isolate the mains power supply before removing the unit from the backplate. Do not mix old and new batteries. Do not use rechargeable batteries. Please leave these instructions with the end user where they should be kept in a safe place for future reference Installation TPSRF51 Control Unit is easily installed using the backplate supplied with the unit this is purely for mounting purposes, as no wiring is needed for the Control Unit. The backplate can be mounted directly to the wall surface without using a back box. The ideal position to locate the TPSRF51 RF Programmable Room Thermostat is about 1.5m above floor level, in a location where the thermostat is accessible, reasonably lit and free from extremes of temperature and draughts. Do not mount the thermostat on an outside wall, above a radiator or in a location where it may be subjected to direct sunlight. To ensure trouble free receiving of the Radio Frequency (RF) signal, always ensure that the programmable thermostat is mounted away from any possible sources of interference (such as radio, TV sets, computer, etc.), locating the TPSRF51 in enclosed areas such as cellars and basements is not recommended, position your thermostat where the temperature will be representative of that in the zone being controlled. Connecting the TPSRF51 RF Receiver NOTE : All electrical installation work should be carried out by a suitably qualified Electrician or other competent person. If you are not sure how to install this digital thermostat consult either with a qualified electrician, heating engineer or your boiler/heating system supplier for advice on how to continue. The TPSRF51 Receiver should be mounted in a suitable location that is both accessible for the connection of mains and control wiring, and allows good reception of the RF signal. The Receiver needs a 230V AC mains supply to operate, and this should be fused appropriately (13A max.) The Receiver should be mounted in a location where it will not come into contact with water, moisture or condensation. The Receiver On/Off switch is accessible from the front face of the Receiver. 1

On the front cover of the Receiver you will see that there is the On/Off switch and two light emitting diodes (LEDs). The switch allows you to turn off the Receiver if necessary to prevent it calling for heat. The top LED (orange) will illuminate when the switch is in the On position and the unit is receiving power. The bottom LED (green) illuminates when the Receiver unit is receiving a heat call transmission from the Control Unit. The wiring terminals and RF Address Code setting DIP switches are located on the rear of the Receiver. Receiver Wiring Terminals Terminal Name N L 1:COM 2:NO 3:NC Function Neutral input 230VAC/50Hz Live input 230VAC/50Hz Switch common terminal Normal open (Volt-Free Contact) Normal close (Volt-Free Contact) Direct Control Boiler RECEIVER BOILER N.0. COM L N Blue N MAINS L FEED Live Feed L N E Blue Green/Yellow Notes: Receiver unit should have a permanent 230V AC main supply Combi Boiler RECEIVER BOILER N.0. COM L N Thermostat (Remove link) Blue N L MAINS FEED N L SL Live Feed L N E Blue Green/Yellow Notes: Receiver unit should have a permanent 230V AC main supply If the boiler has two terminals for the thermostat, remove the link from the boiler 2

Control Unit Jumper Settings Changes to the jumper settings should only be made by the Engineer carrying out the installation or other qualified person. The installer should select the jumper positions required if changes need to be made to the factory default settings. These jumpers are found on the rear of the Control Unit. Jumpers Address code Span Description 5 DIP switch levers for 5 bits address code for RF communication (All jumpers default are closed) 3x1 pins jumper for +/-0.5 C or 1.0 C (factory default setting) selection It is used to define the system to run at +/-0.5 C or 1.0 C difference to the set temperature Notes : The Reset button must be pressed after changing jumper positions. The Reset button is accessible behind the small hinged door on the front right hand side of the Control Unit. RF Address Code Setting If there is another unit being used nearby, e.g. in the next house or as part of a multiple installation, your Receiver may be triggered by the other Control Unit. You can change the RF Address Code to help to prevent this problem. Each Receiver can only respond to RF transmissions from a Control Unit that has the same RF address code setting. Disconnect any AC power to the Receiver, and remove the batteries from the Control Unit before attempting any adjustment of the RF Address Code switch and jumpers. If you are not sure how to carry out this operation correctly, consult either with a qualified electrician or heating engineer. To adjust the RF address code of the Receiver, simply push up one or more of the 5 DIP switch levers on the DIP switch bank located on the back of the Receiver, and then make a note of the setting of each switch. To adjust the RF address code of the Receiver, simply push up one or more of the 5 DIP switch levers on the DIP switch bank located on the back of the Receiver, and then make a note of the setting of each switch. Then set the 5 DIP switch levers on Control Unit same as the RF Receiver setting so that the address code settings match each other. For example, if Receiver DIP switches set as following, Controller unit dip switch should be set as same: 1 ON 2 - OFF 3 - OFF 4 - OFF 5 - ON You must press Reset on the Control Unit after making any changes to the RF address code settings. Testing the RF Transmission It is important to site both the Receiver and Control Unit in locations where the RF signal cannot be interrupted. 3

The receiving range between Control Unit and Receiver is approximately 30 metres indoors, however many factors can affect the RF transmission and shorten the operating distance, e.g. shielding by thick walls, foil back plasterboard, metal objects such as filing cabinets, general RF interference, etc. The range is generally large enough for most household applications, but it is advisable to test the RF transmission from the intended control unit location to the receiver location before fixing the control unit to the wall. To check the RF reception, follow the following steps: 1. Press the button on the Control Centre until the set temperature is higher than room temperature by a few degrees. 2. Wait for a few seconds. The Burner on (heat call) indicator should appear on the bottom left of the LCD on the Control Unit. 3. Check the green LED on the receiver unit it should be lit. 4. Press the button to adjust the set temperature to be lower than room temperature. 5. Wait for a few seconds, and the Burner on (heat call) indicator should disappear and the green LED should switch off. 6. If at step 3 the green LED is not illuminated, press the The Reset on the control unit and try to place the control unit closer to the receiver. 7. Repeat steps 1-5. If you are unable to get a stable RF connection between the Receiver and Control Unit, check that the Receiver is both switched on and has a mains supply (orange LED lit). If this isn t the problem you can also alter the RF address code by following the RF Address Code Setting section of this manual, and should then repeat steps 1 to 5 (note that the Reset button on the Control Unit should be pressed after altering the address code). User Instructions User Control Function Summary Key D H M Set Select ON/OFF Reset Function Increase temperature setting Decrease temperature setting Changes unit to comfort mode Changes unit to economy mode Set the day of the week Set the hour of day Set the minute Key for Program settings Key for Program settings Short Press: Power off mode Long press for 3 seconds: user setting selection for Offset To reset the thermostat 4

Function of indicator Indicator Day of week indicator 1 Function 1. show the current day in normal mode 2. show the program day in program mode Real time clock 2 1. show the current time 2. show the set time during program mode 3 Temperature 1. show the room temperature in the resolution of 0.5 C 2. show the set temperature during program mode in the resolution of 0.5 C 4 Program No. indicator Show the current program number 5 Heat indicator Indicates the channel is turned on for heating 6 Low-batt indicator Indicates battery replacement is required 7 Auto/Comf/Econ/Off mode indicator Indicates current mode: Auto/Comfort/Economy/Off 8 Set icon Indicates unit in setting mode 9 Program icon Indicates unit in programming mode. Both SET and PROG are shown at the same time as SET PROG 10 Snowflake icon Indicates when unit is in OFF mode Initial Power Up: After power up or Reset is pressed, the thermostat is reset. During system reset, all LCD segments are turned on for 2 seconds or until any key is pressed. After 2 seconds and all keys are released, the thermostat is initialized. The typical reset display is shown below. 5

Following table is the setting of the thermostat after reset. Default Operation Mode Setpoint Mode Default settings Comf mode 21 C Econ mode 16 C Off mode 5 C Default Clock and Operation Mode Item Clock Day of week Mode Program Default values 12:00AM Monday AUTO 5/2 days Default Program Setpoint Temperatures Program Weekday (Mon to Fri) Weekend (Sat to Sun) Time: 06:30 Time: 08:00 1 Temp: 21 C Temp: 21 C Time: 08:00 Time: 10:00 2 Temp: 18 C Temp: 21 C Time: 12:00 Time: 12:00 3 Temp: 21 C Temp: 21 C Time: 14:00 Time: 14:00 4 Temp: 18 C Temp: 21 C Time: 18:00 Time: 18:00 5 Temp: 21 C Temp: 21 C Time: 22:30 Time: 23:00 6 Temp: 16 C Temp: 16 C 6

Day/Time Setting To set the day, press D repeatedly to step through. Press and hold the key 2 seconds, the Day of the Week will change continuously. To set the hour, press H repeatedly to step through. Press and hold the key, the numbers will change continuously. To set the minute, press M repeatedly to step through. Press and hold the key 2 seconds, the numbers will change continuously. View/Change temperature setting mode In the home screen in Auto/Comfort/Economy/Off mode, press or o enter View/Change temperature settings. The LCD will show the current temperature setting with flashing numbers and the SET icon is displayed. Press or again to increase or decrease the set temperature in 0.5 C steps. Press and Hold or for 2 seconds to enter fast advance in 1.0 C steps. In Auto/Comfort/Economy mode, the temperature can be set from 5 C to 30 C. In OFF mode, the temperature is set at 5 C and cannot be changed. During changing the set temperature, only, and Set have functionality. If the Set key is pressed or no further keys have been pressed after 5 seconds, the setting is saved and it will return to the home screen automatically. Change Operation Mode The thermostat can operate in four different modes: AUTO, COMF, ECON or OFF. The default mode is AUTO. 1) COMF mode Press anytime in other modes to enter COMF mode. The screen displays and the setting flashes for 5 seconds. When the temperature flashes, the setting can be changed (default 21 C) by using ᴧ or ᴠ in increments of 0.5 C. Press and hold the buttons, the setting will change continuously in increments of 1.0 C. Wait 5 seconds to confirm the temperature. Next time the thermostat is in COMF Mode, this setting will be remembered. Anytime during the COMF mode press, it will go back to the AUTO (automatic) mode. Symbol on the LCD will be off, icon will be displayed. 2) ECON mode Press anytime to change into ECON mode. will be displayed on the LCD. Change the setting (default 16 C) the same as in COMF mode. Anytime during the ECON mode, press return to AUTO (automatic) mode to 3) AUTO mode Automatic mode sets the thermostat to follow the temperature program. LCD. Change the setting the same as in COMF mode. is displayed on 4) OFF mode Off mode sets the thermostat to maintain a minimum temperature of 5 C (default) that acts as a frost protection measure. This value cannot be changed. In AUTO/COMF/ECON mode, pressing ON/OFF will change to OFF mode. In OFF mode, press ON/OFF again to revert to the previous mode. In OFF mode, press In OFF mode, press to change into COMF mode. Press again to change to Auto mode. to change into ECON mode. Press again to change to Auto mode. 7

Temporary Override Mode During AUTO mode, the programmed temperature can be adjusted manually by pressing the or buttons. The setting will flash for 5 seconds, then return to the home screen. This temperature override is cancelled at the next programmed temperature change. During Temporary Override mode, the program number is not displayed. Temporary Override mode remains active until the clock or program settings are adjusted, COMF/ECON/OFF mode is activated, or the next program time is reached. Program Setting Mode You can change the program setting as follows: 1. Press Set to enter programming mode. Days will flash on the LCD for 10 seconds. Press or repeatedly to step through the days, in consequent of 7 day, 5/2 day and 24 hour programme options: --- [M], [TU], [W], [TH], [F], [SA], [SU] -- [M, TU, W, TH, F], [SA, SU] -- [M, TU, W, TH, F, SA, SU] 2. Press Select at any time to confirm the selection. Press Set to return to the home screen. 3. Program 1 will display with the Hours flashing. Press or to change. Press Select to set the hour. Press Set to return to the home screen and store the setting. 4. Program 1 will be displayed with the Minutes flashing, press or to change Press Select to set the minute Press Set to return to the home screen and store the setting. 5. Program 1 will display with the temperature flashing, press or to change Press Select to set the temperature. Press Set to return to the home screen and store the setting. 6. Program 1 and its temperature is set, Program 2 and the Hour will flash for 10 seconds to allow you to set, repeat steps 3 to 5 (above). 7. After Program 6 is set, the next Day will flash as in step 1. 8. Repeat step 1 to 6 to set the rest days. Note: During steps 1-8 (above), only or, Select and Set have functionality. During steps 1-8 (above), if there is no key press within 10 seconds, the unit will store the current setting and return to AUTO mode. Chronological sequence of programming If you set the start time of a programme to be later than a subsequent set programme, the subsequent programme start time will be changed to the same. Similarly, if you set the time earlier than the previous program, the previous program start time will be changed. The temperature setting will also be changed. See following examples: Original Program 1 Time: 06:30am Temp: 21 C 2 Time: 08:00am Temp: 18 C 3 Time: 10:00am Temp: 23 C 4 Time: 12:00pm Temp: 21 C 5 Time: 6:00pm Temp: 21 C 6 Time: 10:30pm Temp: 16 C 8

Now if you change program 2 start time from 8.00am to 1.00pm, the new program setting is as below and uses the temperature setting of the last period as the current setting i.e. use 21 C in our example. New Program 1 Time: 06:30am Temp: 21 C 2 Time: 1:00pm Temp: 18 C 3 Time: 1:00pm Temp: 23 C 4 Time: 1:00pm Temp: 21 C 5 Time: 6:00pm Temp: 21 C 6 Time: 10:30pm Temp: 16 C Similarly, if you set the time earlier than a previous program time, similar changes are applied. For example: Original Program 1 Time: 06:30am Setpoint Temp: 21 C 2 Time: 08:00am Setpoint Temp: 18 C 3 Time: 10:00am Setpoint Temp: 23 C 4 Time: 12:00pm Setpoint Temp: 21 C 5 Time: 6:00pm Setpoint Temp: 19 C 6 Time: 10:30pm Setpoint Temp: 16 C If you change program 5 start time from 6pm to 7am. The new program setting is as below using the temperature setting of the last conflicting programme i.e. uses 19 C in our example. New Program 1 Time: 06:30am Setpoint Temp: 21 C 2 Time: 7:00am Setpoint Temp: 18 C 3 Time: 7:00am Setpoint Temp: 23 C 4 Time: 7:00am Setpoint Temp: 21 C 5 Time: 7:00am Setpoint Temp: 19 C 6 Time: 10:30pm Setpoint Temp: 16 C Installer Setting Mode: There is one setting for installer: Offset from -3.0 C to +3.0 C. 1. Press and hold ON/OFF over 2 seconds, the unit is in Offset selection. LCD will display OFS and stored offset temperature. 2. Press or to change offset by 0.5 C steps. 3. Press Select to save the value and return to the home screen. Note: During any time if there is no subsequent key press within 10 seconds or Set is pressed, the unit will store the setting and return to the home screen. 9

Temperature measurement Temperature Sampling Rate: Every 15 seconds while backlight is off Temperatures exceeding the measurement range (0.0 C - 35 C) will be indicated by HI and LO. Control Status Indication: Heating indicator is displayed when the heat channel is switched ON. Low Battery When battery voltage below 2.4V, the low battery indicator When low battery occurs, the backlight will not illuminate. will be displayed on LCD. Battery Cut-off Handling When the batteries reach cut-off voltage 2.1V, the LCD will turn off. After battery cut-off occurs, the thermostat will enter a cut-off state until new batteries have been fitted. BOSS is a registered trademark of the Travis Perkins Group Registered Office: Travis Perkins plc, Lodge Way House, Lodge Way, Harlestone Road, Northampton. NN5 7UG 10