Radio Thermostat Clock

Similar documents
Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

EN Wireless programmable thermostat

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

Instruction Manual for Programmable Digital Timer

ST625TX Digital Room Thermostat

SCS318. User Instructions. SCS318 comprising of SCS317 7 Day Wireless Programmable Room Thermostat and SSR303 Receiver

7 Day Digital Light Switch with Optional Dusk Start

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

Programmable Room Thermostat With RF

Digital Time Switch. Installation & Operating Instructions

7 Day Digital Time Switch

7 Day Digital Programmer 3 Channel Surface Mount

Operating instructions. Universal timer switch display

Ducasa Digital Programmer

TP7001 Range Electronic 7 Day Programmable Room Thermostat. Danfoss Heating. Installation Guide

RT505TX Programmable. The RT505TX can be used with any of these receivers RXBC605 RXWBC605 RXVBC605 RXST MHz

S-Series Digital Thermostat. Instruction Manual Model No ST620RF

1 Channel Multi-Purpose Programmer User Instructions

ULTRA-VANSTAT WIRELESS PROGRAMMABLE THERMOSTAT FOR CARAVANS

7 Day Digital Programmer

Inserting the batteries. Basic settings of the remote control

USER & ENGINEER INSTRUCTION MANUAL

Cronotermostato Digitale

User interface. Abbreviations / Meanings

Room thermostat Instructions for Use. For the user. Instructions for Use. geotherm

Installation & Programming Manual. Please read before using this timer.

ServicePlus S17R Series 2 User Operating Instructions

TDDFM14 OWNER S MANUAL

Digital Economy Seven Programmer

Model IQ4-PC User Manual Revision Date:

Junior Max (JR Max ) Controller

Index. English. English User Manual Eco.X

SAUTER flexotron RDT405 Manual

Comfort System T-32-P Universal Thermostat. Operation Manual

24Hour/7Day Electronic Timeswitch

Operation Guide 6022 ENGLISH

Tebis TX100 Configurator

24 Hour & 7 Day Digital Immersion Heater Timeswitch Article

Operating Instructions. Room temperature controller with clock

External RF programmable room thermostat 411

PLC Control Unit for a CSM-E Electrical Compact Clean Steam Generator

Schneider Industries SAS MTN5812../MTN MTN Time switch

ACT 10 Digital Keypad Operating & Installation Instructions This manual is found at

System pro M DT1-IK DT1-IK/24V DT1-IK/DCF DT2-IK 2CSM204275R0611 2CSM441017D5601 2CSM204285R0611 2CSM204295R0611 2CSM204325R0611

Timer Modules. EL11 24 Hour Module EL17 7 Day Module. Installation & Operating Instructions

Waterline Room Controller - Type WLCT3

TU-8A. 8 Channel Digital Timer Unit. Programming Guide

TORK DGU100/DGUM100 7 DAY DIGITAL TIME SWITCH INSTALLATION AND OPERATING INSTRUCTIONS READ INSTRUCTIONS CAREFULLY BEFORE SETTING UNIT

ChannelPlus H17XL Series 2 User Operating Instructions

APOLO DC B Electric Thermal Radiators

ST9100C User Guide. Features

AHP-1200CPV Cold/Warm Plate Product Manual Volume 1.3

Tebis application software

TRANSCENSION 6-CHANNEL DMX DIMMER PACK (order code: BOTE40) USER MANUAL

talento 800 Series 365-Day One, Two and Four Circuit Electronic Time Controls Functional Description

User Manual CC DC 24 V 5A. Universal Control Unit UC-1-E. General Information SET. Universal Control Unit UC-1 Of Central Lubrication PAUSE CONTACT

Two (2) Channel 365 Day 24 Hr. Timer/Controllers

Master Time Clock MTC Users Manual

Timer Modules. MEU11 24 Hour Module, MEU17 7 Day Module (Without Housing)

Programmable time switches Multiple function - daily/weekly

Chronothermostat IRIDE. User Manual

DIGITAL TIME SWITCH 7 DAY WITH INPUT DGU100A DGUM100A DGLC100A DGLC200A

Ambient Weather WS-01 Intelligent Color Changing Temperature Night Light with Ambient Backlight User Manual

PT Two (2) Channel 365 Day 24 Hr. Timer/Controller

CP017 USER OPERATING INSTRUCTIONS. Single Channel Timeswitch

FD Trinitron Colour Television

WiFi Controlled Fused Spur Time Switch

Ambient Weather WS-01T-C Color Changing Wireless Temperature Night Light with Ambient Backlight (Console Only) User Manual

Slimline Digital Electric Radiator. Step by Step Programming Guide

TORK DGS180 DIGITAL SIGNAL TIMER 24 HOUR WITH DAY OMIT

DLP200M 2 Relay Module for Heating and Cooling Plants

2 2 Relay outputs. M DIN W72 H7mm. LE7 Weekly/Yearly timer

INSTALLATION & OPERATING INSTRUCTIONS SINGLE/TWO CHANNEL 24HR/7 DAY TIMER. Cat No. TR671/TR672TOP

Simply clever! The digital DIN-rail time switches by Grässlin

CP027. User Operating Instructions. Two Channel Central Heating and Hot Water Programmer

7 DAY DIGITAL LIGHTSWITCH WITH OPTIONAL DUSK START INSTALLATION & OPERATING. Cat No. ZV700 INSTRUCTIONS

FW/S Digital time switch 2CDG120039R0011 D GB F I E NL. Installation and operating instructions FW/S DCF antenna GPS antenna SELV MENU

B. The specified product shall be manufactured by a firm whose quality system is in compliance with the I.S./ISO 9001/EN 29001, QUALITY SYSTEM.

GET STARTED. For assistance, call us on or visit manhattan-tv.com/help

INSTRUCTION MANUAL DLC400BP DIGITIAL LIGHTING CONTROLLER FOR TECHNICAL SUPPORT: USA

VLC-3 USER'S MANUAL. Light Program Controller. M rev. 04 K rev. 00 & ( ( 5, 352*5$0 1 : $ 2 ' 6(77,1*6 )81&7,216

RWL11X2 GREENHOUSE CONTROLLER. Operation Manual

CONTENTS 8 ACCESSORIES 13 9 TROUBLE SHOOTING AND ADVICE SPECIFICATIONS BATTERY USAGE CAUTION 13

Single cable multiswich programmer PC102W

LCD Thermometer / Clock S No. 1253

XTM72E & F Real-Time Clock Modules

Operating Manual. Basic Control BC16. two-channel for eco moon

Philips LightMaster. KNX Timeclock Installation and Operation Manual

CAUTION RISK OF ELECTRIC SHOCK NO NOT OPEN

16 Amp Electronic 24 Hour/7 Day Time Controller

Installation and Operation Manual. YMP Series Signal Programmer

) AMANO. ,i CINCINNATI ELECTRONIC TIME RECORDER EX 6000 SERIES

USER S GUIDE. The Gen5 MotivAider. The ultimate tool for people who are serious about changing their own behavior and habits. Support Contact Us

Sample BD Tech Concepts LLC

Westerstrand T/T- display

M150SP USER S AND INSTALLER S MANUAL. v2.0 REV. 03/2017

SINGLE ZONE CLIMATE ZONING SYSTEM. Technical Manual. Polyaire Pty Ltd

Standard Digital Terminal High-Definition Digital Terminal. User Guide

Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual

Luminaire installation box Surface-mounted box Ceiling installation box

Transcription:

Radio Thermostat Clock Installation & User Instructions Part number: ZU0800009 80.10.1375.7_feeling_ks_fer_en.indd 1 18.04.2013 11:25:42

Table of contents Safety instructions... 3 Product details... 4 User menu/configuration... 39 Installation menu... 40 Installation and assembly... 7 Operating and adjustment... 15 Configuration... 18 Initial start-up... 19 Settings... 25 Operating modes... 29 Operating status... 36 2 80.10.1375.7_feeling_ks_fer_en.indd 2 18.04.2013 11:25:42

Safety instructions DANGER Danger from electric shock! The connection and installation of electrical devices may only be carried out by a qualified electrician. It is imperative to observe the generally applicable safety measures, e.g. before starting any work on the appliance, switch off power supply and secure against switching on. Interventions in and changes to the device result in the voiding of the warranty claim. Observe your national regulations and the respective safety provisions. 3 80.10.1375.7_feeling_ks_fer_en.indd 3 18.04.2013 11:25:42

Product details The radio thermostat clock is a 7 day radio frequency (RF) wireless thermostat/ timer which communicates with a special receiver designed to fit in the clock aperture of the boiler casing. A B The radio thermostat clock is battery powered and can be sited wherever conventional room thermostats would normally be sited. See installation locations information on page 7. The radio thermostat clock is a room thermostat and clock of highly advanced technology. The device is wireless and controls the heating via radio, providing both time control and comfortable room temperatures. F C D E Assembly description A Moveable sliding cover B Keys for manual override function 4 C Window D Keyboard E Battery compartment F Display 80.10.1375.7_feeling_ks_fer_en.indd 4 18.04.2013 11:25:43

Technical data RF Set, Transmitter Power supply: 2 x 1.5 V AA LR6 alkaline batteries Battery service life: 2 years (depending on switching frequency) Room temperature display resolution: 0.1ºC Temperature setting display: Program: +5ºC +32ºC (0.5ºC steps) Frost protection: 5ºC (adjustable 3ºC 7ºC) Time setting resolution: Time of day: 1 minute Program: 30 minutes Programming: weekly program with up to 48 time and temperature programs changes Pre-programmed programs: 4 + 1 user-defined RF signal: 868.3 MHz RF signal range: Indoor 30 m (2 walls + 1 ceiling) Protection class / type: II / IP40 Operating temperature range: Max. 45ºC Operating humidity range: 10% to 90% RH non-condensing Dimensions H x W x D (mm): 87 x 154 x 27 5 80.10.1375.7_feeling_ks_fer_en.indd 5 18.04.2013 11:25:43

Technical data RF Set, Receiver Power supply: 230 V +/-10% 50-60 Hz Switching output: SPDT (potential-free) Switching capacity: 5 (1) A 250 V AC RF signal: 868.3 MHz RF signal range: Indoor 30 m (2 walls + 1 ceiling) Protection class / type: II / IP20 Operating temperature range: Max. 45ºC Operating humidity range: 10% to 90% RH non-condensing Dimensions H x W x D (mm): 60 x 60 x 32 6 80.10.1375.7_feeling_ks_fer_en.indd 6 18.04.2013 11:25:43

Installation and assembly General information 1.5 m 7 80.10.1375.7_feeling_ks_fer_en.indd 7 18.04.2013 11:25:43

Modena C HE 8 80.10.1375.7_feeling_ks_fer_en.indd 8 18.04.2013 11:25:43

Wiring diagram These spades connect to terminals 1 & 2 at the clock White White N L Radio Thermostat Clock Receiver Remove Link and connect leads to terminals 3 & 4 at the receiver 9 80.10.1375.7_feeling_ks_fer_en.indd 9 18.04.2013 11:25:44

Installation of the receiver Wiring Connections 5 4 3 M~ 2 1 Receiver Button LED 1 - Live (Brown) 2 - Neutral (Blue) 3 - Switched circuit (White #1) 4 - Switched circuit (White #2) 5 - No connection required Commissioning, please turn to page 11. 10 80.10.1375.7_feeling_ks_fer_en.indd 10 18.04.2013 11:25:44

Installation of the radio link The transmitter and receiver are pre-commissioned. If the radio link doesn t work correct, follow the sequence of commissioning. Press and hold the black button of the receiver until the LED light has flashed twice. Release the button and the LED light will remain illuminated. Press and hold MODE-button and SET-button of the transmitter at the same time for more than 3 seconds to enter into the User menu. Then press the ok-button until RF Comm is displayed. Receiver Button 11 80.10.1375.7_feeling_ks_fer_en.indd 11 18.04.2013 11:25:44

Press upper + button ( button disables the RF signal) to enable an continous RF signal. The receiver LED will go out as soon as a signal from the transmitter is received. Then press the ok-button, the radio link between transmitter and receiver is now established. Press the Esc-button to return to Auto mode. Receiver: When operating in heating mode and an ON signal is received, the LED illuminates continously. When an OFF signal is received, the LED is off (and flashes periodically at longer intervals). Is no valid radio signal received from the transmitter for more than one hour (e.g. low battery) the emergency operating mode will be activated. The LED flashes every 0,5 seconds. 12 80.10.1375.7_feeling_ks_fer_en.indd 12 18.04.2013 11:25:45

Open housing Wall mounting 13 80.10.1375.7_feeling_ks_fer_en.indd 13 18.04.2013 11:25:45

Close housing Insert batteries click! click! Only use 2 x 1.5 V type AA. 14 80.10.1375.7_feeling_ks_fer_en.indd 14 18.04.2013 11:25:46

Operating and adjustment Operating information Flashing texts signal the need for an entry. If no button is pressed for 2 minutes, the device reverts to the Automatic mode. All settings need to be confirmed with OK. All settings saved will remain in the memory. The histogram shows the programmed temperature profile 7 14 C = displayed as one segment 15 24 C = one segment displays 1 C over 24 C = one segment displays 2 C 15 80.10.1375.7_feeling_ks_fer_en.indd 15 18.04.2013 11:25:46

Display K J I H A B C D E F G A Current week day B Battery C RF signal D Current time E Set temperature F Off mode G Histogram over 24 hours H Current temperature I Operating mode J Status indication K Current date 16 80.10.1375.7_feeling_ks_fer_en.indd 16 18.04.2013 11:25:47

Function keys B D A C E F G A +/ buttons used to increase/decrease temperatures. B OK-button to confirm settings and go to the next step. C Mode-button to select from the available operating modes. D Esc-button used for ON/OFF, go one step back in menu or return to main menu by pressing the button more than 3 seconds. E Set-button for settings following commissioning. F +/ buttons used to increase/decrease hours, days and events. G Reset-button to return to factory settings. The programs are retained in the case of a reset. The date and time must be set again. Press reset button with a blunt object (pen). 17 80.10.1375.7_feeling_ks_fer_en.indd 17 18.04.2013 11:25:47

Configuration General information For the use of this manual you must observe the following informations: A B A Sequence of operation B Pressed buttons are shown in black. C Flashing elements are shown in black D Fixed elements are shown in grey D C Buttons which can be pressed during an action are shown in black. The related display is also shown in black. Follow exactly the numbers of the sequence of operation. The configuration of the device is described based on configuration. After starting the device for the first time, follow the menu for a correct configuration of the device. Following commissioning, you can also change the configuration by pressing the set-button. 18 80.10.1375.7_feeling_ks_fer_en.indd 18 18.04.2013 11:25:47

Initial start-up Set date and time Sequence for setting the date and time during initial start-up. 15/6/2008 appears as factory default. To set the date and time after initial start-up press the SET-button, then choose Date or Time Menu with the upper +/ buttons and confirm with OK. 19 80.10.1375.7_feeling_ks_fer_en.indd 19 18.04.2013 11:25:48

The time is set in the same way as the date. 20 80.10.1375.7_feeling_ks_fer_en.indd 20 18.04.2013 11:25:49

Programming Sequence for specifying programs during initial start-up. To specify programs after initial start-up press the SET-button, then choose the Prog menu with the upper +/ buttons and confirm with OK. 21 80.10.1375.7_feeling_ks_fer_en.indd 21 18.04.2013 11:25:49

Mo Tu We Th Fr Sa Su Choose between: 7 days one programm 5-2 days one program per day block 1-7 days each day an individual program free block formation one program per day block 22 80.10.1375.7_feeling_ks_fer_en.indd 22 18.04.2013 11:25:51

Select program Each weekday or day block must be allocated a program P1, P2, P3, P4 (pre-defined) or Pd (userdefined). P1 P2 15 C 20 C 17 C 21 C 15 C 15 C 20 C 17 C 21 C 15 C P3 P4 15 C 20 C 18 C 20 C 17 C 21 C 15 C 15 C 20 C 17 C 21 C 15 C Pd User-defined program. During initial start-up, program will be shown with 15ºC from 00:00 to 23:59 PM. 23 80.10.1375.7_feeling_ks_fer_en.indd 23 18.04.2013 11:25:51

If you wish you can modify the pre-defined programs. Use the upper +/ buttons to increase/decrease the temperature of each segment by 0.5 C. Use the lower +/ buttons to go forward/backward 30 minutes each time and copy the selected temperature value. 24 80.10.1375.7_feeling_ks_fer_en.indd 24 18.04.2013 11:25:52

Settings After commissioning you can change the date, time, temperature and time programming. By pressing the upper +/ buttons you jump to the different menus. 1-3 = adjustment of date 2-3 = adjustment of time 3-3 = adjustment of time and temperature programming 25 80.10.1375.7_feeling_ks_fer_en.indd 25 18.04.2013 11:25:52

You are now able to adjust the date as described in the initial start-up. The sequence of setting the time is similar to the method for settingthe date. With the lower +/ buttons you can choose days or day blocks for programming and confirm with OK. Go to operation number. By pressing the ok-button you can choose between the pre-defined programs P1 P4 or the user-defined program Pd. Go to operation number. 26 80.10.1375.7_feeling_ks_fer_en.indd 26 18.04.2013 11:25:53

80.10.1375.7_feeling_ks_fer_en.indd 27 18.04.2013 11:25:54 27

By pressing the lower +/ buttons you can go through the program to check it. For editing the program, use the upper +/ buttons to increase/decrease temperature in each segment by 0.5 C. Use the lower +/ buttons to go forward/backward and copy the selected temperature value. 28 80.10.1375.7_feeling_ks_fer_en.indd 28 18.04.2013 11:25:55

Operating modes Set operating modes Follow the sequence for selecting the desired operating mode. The operating modes in the device appear in the same order as described here. Press and hold the ESC-button for 3 seconds to return to Auto mode. Example: 29 80.10.1375.7_feeling_ks_fer_en.indd 29 18.04.2013 11:25:55

Auto Symbol: After each programming session, the device automatically returns to the Auto mode. The predefined or user-defined program run here. 30 80.10.1375.7_feeling_ks_fer_en.indd 30 18.04.2013 11:25:55

Manual-ECO-Fix Symbol: Manual-ECO-Fix mode calculates an average temperature of the actual program. This temperature is is kept for the whole day until any user s intervention is made. To return to Auto mode, press OK. The average temperature is the starting point for increasing or decreasing the desired temperature, pressing upper +/ buttons. The new temperature set value is then, after 3 sec., set for all day long. Example: 4 different temperatures in the actual program (e.g. 17 C, 19 C, 20 C and 22 C). Average temperature is then 19,5 C. 31 80.10.1375.7_feeling_ks_fer_en.indd 31 18.04.2013 11:25:56

Cleaning mode Symbol: This mode sets the device into OFF mode for a preset time of 2 hours. During the cleaning time, remaining time is shown until running mode elapsed. After the Cleaning mode is elapsed, the device returns into Auto mode. To end Cleaning mode early, press Esc-button for more than 3 seconds. The anti-freeze protection is granted. 32 80.10.1375.7_feeling_ks_fer_en.indd 32 18.04.2013 11:25:56

Countdown mode Symbol: This function runs into a desired set temperature during certain period of time. Adjustable period of time is 1 23 hours. After the time is elapsed, the device returns into OFF mode (Anti-freeze temperature is kept). During the Countdown mode, remaining countdown time is indicated. Example: The device shall be run into OFF mode after 4 hours. To end Countdown mode early, press Esc-button for more than 3 seconds. 33 80.10.1375.7_feeling_ks_fer_en.indd 33 18.04.2013 11:25:56

Party mode Symbol: This mode allows the user to set a desired temperature during defined period of time. Adjustable period of time is 1 23 hours. After the time is elapsed, the device returns into the mode before the Party mode was activated. During the Party mode, the rest of the time is indicated. Example: The temperature shall be set for 6 hours on 24 C. To end Party mode early, press Esc-button for more than 3 seconds. 34 80.10.1375.7_feeling_ks_fer_en.indd 34 18.04.2013 11:25:57

Holiday mode Symbol: This function runs into a desired set temperature during certain period of time. Adjustable period of time is 1 90 days. After the time is elapsed, the device returns into the mode before the Holiday mode was activated. During the Holiday mode, the rest of the days is indicated. Example: The temperature shall be set for 16 days on 13 C. To end Holiday mode early, press Esc-button for more than 3 seconds. 35 80.10.1375.7_feeling_ks_fer_en.indd 35 18.04.2013 11:25:57

Operating status Manual override Symbol: While the sliding cover is closed, you can temporarily adjust the temperature in the current period with the upper +/ buttons. It is not necessary to confirm the setting with OK. The setting will remain as temperature set value until the next programmed change (time and temperature) appears. To return into Auto mode, press and hold upper +/ buttons for 3 seconds, or open the sliding cover and press OK-button. 36 80.10.1375.7_feeling_ks_fer_en.indd 36 18.04.2013 11:25:58

OFF mode Symbol: This mode switch off the device completely. To activate this mode press and hold On/Off/Esc-button for more than 5 seconds. To leave this mode press and hold the On/Off/Esc-button again for more than 5 seconds. The anti-freeze protection is granted. >5 sec 37 80.10.1375.7_feeling_ks_fer_en.indd 37 18.04.2013 11:25:58

Low battery Symbol: A low battery level is indicated with the battery icon in the display. Please change the batteries. If batteries are not placed or are installed in the wrong polarity, <Bat> text will appears on display until they are placed or installed in the right polarity. If the battery goes completely empty, the programming is protected. 38 80.10.1375.7_feeling_ks_fer_en.indd 38 18.04.2013 11:25:58

User menu/configuration Symbol: Press the Mode-button and set-button at the same time until User menu is shown in the display. To go to previous menu press Esc-button. It is possible to adjust: RF commissioning (RFC): Enable/disable continuous radio signal Offset (OFS): Possibility to adjust/modify the measured temperature (-5 C...+5 C) Summer/Winter time (SWT): enable/disable automatic summer/winter time change Time Format (TMF): possibility to change time format into 24 hours or 12 hours (default: 24 hours) Restore Default (DFL): Restore values to factory default status. Use lower +/ buttons to navigate through menus. Use upper +/ buttons to change values and OK to confirm. 39 80.10.1375.7_feeling_ks_fer_en.indd 39 18.04.2013 11:25:58

Installation menu Symbol: To access this Configuration menu, press the Mode-button, the ok-button and set-button at the same time until Installer menu is shown in the display. Press ESC-button to go to previous Menu. The adjustments in this menu are only for experts. All possibilities for adjustment are shown with a self-explaining, floating real text in the display. Use lower +/ buttons to navigate through menus. Use upper +/ buttons to change values and OK to confirm. 40 80.10.1375.7_feeling_ks_fer_en.indd 40 18.04.2013 11:25:59

Following adjustments are possible: High Temp (HIT): set maximum temperature value for programming from low temperature value up to +32 C (default: +32 C) Low Temp (LOT): set minimum temperature value for programming from +7 C up to high temperature value (default: +7 C) Frost protection (FRT): set anti freeze minimum temperature value from +3 C to +7 C (default: 5 C) Regulation (REG): possibility to select between PID or 2 points regulation (default: 2 points) Differential (DIF): possibility to modify differential value from 0,1 K to 0,9 K (default: 0,2 K) Keypad Lock (LOK): enable keypad to protect against non authorized interventions To enable/disable the keypad lock press and hold Mode- and ESC-button for more than 3 seconds. Operating hours (OPT): this feature shows total operating running time (max. 99.999 hours) Battery Level (BAT): battery charge level is shown on display 41 80.10.1375.7_feeling_ks_fer_en.indd 41 18.04.2013 11:25:59

For your notes: 80.10.1375.7_feeling_ks_fer_en.indd 42 18.04.2013 11:25:59

For your notes: 80.10.1375.7_feeling_ks_fer_en.indd 43 18.04.2013 11:25:59

Because of our constant endeavour for improvement details may vary from those quoted in these instructions Should you require any assistance during the installation call our Technical Service Helpline on 0843 479 0 479 Ferroli Limited, Lichfield Road, Branston Industrial Estate, Burton Upon Trent, Staffordhshire, DE14 3HD Service/Technical Tel: 0843 479 0 479 80.10.1375.7/13/13/01 80.10.1375.7_feeling_ks_fer_en.indd 44 18.04.2013 11:25:59