1. General Information:

7 Day Digital Time Switch

Digital Time Switch. Installation & Operating Instructions

7 Day Digital Programmer 3 Channel Surface Mount

2 Hour Electronic Boost Timer

7 Day Digital Light Switch with Optional Dusk Start

16 Amp Electronic 24 Hour/7 Day Time Controller

Timer Modules. EL11 24 Hour Module EL17 7 Day Module. Installation & Operating Instructions

WiFi Controlled Fused Spur Time Switch

Timer Modules. MEU11 24 Hour Module, MEU17 7 Day Module (Without Housing)

7 Day Digital Programmer

24Hour/7Day Electronic Timeswitch

Electronic 7 User Operating Instructions

7 DAY DIGITAL LIGHTSWITCH WITH OPTIONAL DUSK START INSTALLATION & OPERATING. Cat No. ZV700 INSTRUCTIONS

24 Hour & 7 Day Digital Immersion Heater Timeswitch Article

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

18W Low Energy Dusk-Dawn Bulkhead E-290B

INSTALLATION & OPERATING INSTRUCTIONS SINGLE/TWO CHANNEL 24HR/7 DAY TIMER. Cat No. TR671/TR672TOP

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

SceneStyle2 User Guide

Projector Lift. User Guide INSTALLATION OPERATION SETUP PROGRAM IR REMOTE FACTORY RESET

CP027. User Operating Instructions. Two Channel Central Heating and Hot Water Programmer

INSTALLATION AND OPERATING MANUAL FOR ALL MATSUKO SWITCHBOX MODELS SWB 5 SWB 5P SWB 5P+PG WARNING:

Aspect 2 Circuit Digital Scene Control

Master Time Clock MTC Users Manual

RD RACK MOUNT DIMMER OWNERS MANUAL VERSION /09/2011

CP017 USER OPERATING INSTRUCTIONS. Single Channel Timeswitch

Safety FIND THE FEED CABLE IN YOUR ELECTRICITY METER (UK)

Radio Thermostat Clock

BT Diverse Repeater. User Guide

DRIVER 230 CPL 3 zone weekly programmer using power line carriers

OWNERS MANUAL. Revision /01/ Lightronics Inc. 509 Central Drive Virginia Beach, VA Tel

Dial Ezy INSTRUCTION MANUAL N IRRIGATION CONTROLLER 4 or 6 Station Model SUITABLE FOR INDOOR USE ONLY OTHERWISE WARRANTY IS VOID

Schneider Industries SAS MTN5812../MTN MTN Time switch

ServicePlus S17R Series 2 User Operating Instructions

DLP200M 2 Relay Module for Heating and Cooling Plants

multi-function meters

DLP600M 6+1 Relay Module for Heating and Cooling Plants

Junior Max (JR Max ) Controller

Telemetry Receiver Installation Guide

FD Trinitron Colour Television

Programmable Room Thermostat With RF

Nixie Clock Type Quattro'

ChannelPlus H17XL Series 2 User Operating Instructions

SINGLE ZONE CLIMATE ZONING SYSTEM. Technical Manual. Polyaire Pty Ltd

VLC-3 USER'S MANUAL. Light Program Controller. M rev. 04 K rev. 00 & ( ( 5, 352*5$0 1 : $ 2 ' 6(77,1*6 )81&7,216

DIGITAL TIME SWITCH 7 DAY WITH INPUT DGU100A DGUM100A DGLC100A DGLC200A

EA63-7D. Generator Automatic Voltage Regulator Operation Manual. Self Excited Automatic Voltage Regulator

Operating Instructions Dimmer for V Incandescent Lamps

Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual

SR - 516D DESK TOP DMX REMOTE STATION. Version: Date: 05/16/2013

Peak Atlas IT. RJ45 Network Cable Analyser Model UTP05. Designed and manufactured with pride in the UK. User Guide

Power Injector 1520 Series

DD E SIG N E D & E N GIN EE R E. Holman Garden Lights App Instruction Manual. Android Android manual

CH1 CH2 CH3 CH4. Master /Fade CH5. 600s CH6. 60s SC1 SC2 SC4 SC3 SC5. SC6 Off/Pro. AL Fade 6 Pro. User guide

Dragonfly Quad. User Manual V1.4. Order code: EQLED101

IQ250 (Mk.1, 2 & 3), IQ500 (Mk.1 & 2),

LP20. Installation & User Guide. Dual Channel Programmer. Part number 25039DR

Operating Manual. Basic Control BC16. two-channel for eco moon

BY-HPE11KTA. Operating Instructions. Coaxial - LAN Converter with PoE function. Indoor Use Only. Model No. Attached Installation Guide

Commander 384. w w w. p r o l i g h t. c o. u k U S E R M A N U A L

Ecomind Electricity Monitor Kit EM422EM-E-KBTS EM422EM-E-KMTS. Installation Instructions

Identification - electrical services

Industriefunkuhren. Technical Manual. IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C / AFNOR NF S87-500

LIGHT COPILOT II. elationlighting.com Internet:

TRANSCENSION 6-CHANNEL DMX DIMMER PACK (order code: BOTE40) USER MANUAL

Heating thermostat Series AMHs B Operating Instructions 11.06/

Access Control Keypad for MK-DV, JB-DV

Electronic converter for level transmitters MT03L Instructions manual

Tectiv 220 Instructions for use

Valcom Wired Digital Clock

System 2000 System 2000 HLK relay insert. 1 Safety instructions. 2 Device components. 3 Function. Order No. : Operating instructions

CONTROL PANEL ENGLISH INSTRUCTIONS MOTORLINE MC 2 / SEAV LRS 2150 SET

M150SP USER S AND INSTALLER S MANUAL. v2.0 REV. 03/2017

REGO Start&Go USER MANUAL

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

TRF STEP-DOWN TRANSFORMER USER MANUAL


Self Excited Automatic Voltage Regulator For Generator Compatible with Marathon SE350* Operation Manual

INSTALLATION AND OPERATION MANUAL

Figure 1: Device components

INSTALLATION AND OPERATION M

EZ Pro Jr. Installation and Programming Guide For EZ Pro TM Jr. models:

User Guide. Centrex Recording Interface

Single Station Waterproof Timer

INSTRUCTION & INSTALLATION GUIDE

Electronic 1-Circuit 7-Day Time Switch With 100-Hour Backup

TP7001 Range Electronic 7 Day Programmable Room Thermostat. Danfoss Heating. Installation Guide

LUNA 129 star-time

Master Clock Controller. User Guide. pyramidtimesystems.com

Installation and Operation Manual. YMP Series Signal Programmer

Lifestyle. Dual Channel Programmer. for heating AND hot water. Installation and User Instructions DUAL CHANNEL ISSA

TORK DGU100/DGUM100 7 DAY DIGITAL TIME SWITCH INSTALLATION AND OPERATING INSTRUCTIONS READ INSTRUCTIONS CAREFULLY BEFORE SETTING UNIT

User Manual CC DC 24 V 5A. Universal Control Unit UC-1-E. General Information SET. Universal Control Unit UC-1 Of Central Lubrication PAUSE CONTACT

CLF Manuals CLF Colour Par CLF Colour 12 Par CLF Colour Par 12 Version 1.0 November 2012 Version 1.0 1

Electronic 2-Circuit 24-Hour Time Switch With 100-Hour Backup

CURRENT INJECTION RELAY TESTER CR-100. ( Code P60212 (770081) ) INSTRUCTIONS MANUAL ( M / 05A ) (c) CIRCUTOR S.A.

GRANT RF CONTROL CENTER INSTALLATION INSTRUCTIONS Always disconnect battery while servicing or modifying the electrical system of the vehicle.

S-Series Digital Thermostat. Instruction Manual Model No ST620RF

Telemetry Receiver Installation Guide

Transcription:

Digital Economy Seven Programmer Model: TRTD7N White Installation & Operating Instructions

1. General Information These instructions should be read carefully and retained for further reference and maintenance. 2. Safety Before installation or maintenance, ensure the mains supply to the time switch is switched off and the circuit supply fuses are removed or the circuit breaker turned off. It is recommended that a qualified electrician is consulted or used for the installation of this time switch and install in accordance with the current IEE wiring and Building Regulations. Check that the total load on the circuit including when this time switch is fitted does not exceed the rating of the circuit cable, fuse or circuit breaker. 1 3. Technical Specifications 230V AC 50 Hz This time switch is of Class l Construction and must be earthed Switch Rating: 13A Resistive (3kW) Immersion Heaters Switch Type: Micro-disconnection ON control. Disconnection to immersion heater(s) via double pole rocker switch 24 hour Programme: 10 selectable pre-set tariff programmes (0 9) Boost Times: 30, 60, 120 minutes Economy Output Light: Blue LED Battery Backup: 2 year reserve, factory fitted rechargeable non-replaceable IP30 Rated suitable for restricted internal applications CE Compliant Dimensions (H x W x D): 111.5 x 170 x 60mm

12 hour display (back lit during programming) Economy light Programming buttons 2 OFF/Timed switch Boost button (illuminated in use) 4. Installation Suitable for use with single, dual, or twin element immersion heaters. 4.1 Ensure the mains supply is switched off and the circuit supply fuses are removed or the circuit breaker turned off. 4.2 Remove the 2 fixing screws holding the front panel to the back box. 4.3 Decide which mounting holes you would like to use and select a suitable cable entry point by drilling into the back box ensuring not damage or infringe on any of the internal components. 4.4 Mark the position of the mounting holes on the wall using the back box as a template. Drill out the mounting holes taking care to avoid any joists, electrical cables or water/gas pipes that may be hidden beneath the surface. Insert the rawl plugs into the holes. 4.5 Pass the 230V 50Hz mains supply and load cables through the cable entry point(s) on the back box. 4.6 Fix the back box to the wall using the correct mounting screws for the rawl plugs installed. 4.7 Use the cable clamp in the back box to secure the cables. 4.8 Terminate the cables into the terminal block ensuring correct polarity is observed and that all bare conductors are sleeved (See section 5. Connection Diagram). 4.9 Select and set your preferred program and time setting using the adjusters located on the reverse of the front panel (See section 6. Commissioning).

5. Connection Diagram Connect the cables to the terminal block which are marked as follows; 230V 50Hz mains Single element immersion heaters only. 1 2 3 4 5 3 230V~50Hz MAINS SUPPLY L N E Heater Neutral Link or Bridge Wire Off Peak Load LOAD Earth 230V 50Hz Mains Supply Live Supply (Brown or Red) to terminal 1 Neutral Supply (Blue or Black) to terminal 2 Earth (Green/Yellow) to Load Switch Live, Off peak load (Brown or Red) to terminal 5 Heater Neutral (Blue or Black) to terminal 3 Earth (Green/Yellow) to Note: a link or bridge will need to be fitted between terminal 4 and terminal 5 if you wish to use the Boost button (single element immersion heaters only).

230V 50Hz mains Twin or Dual element immersion heaters. 1 2 3 4 5 4 230V~50Hz MAINS SUPPLY L N E Heater Neutral Boost Load Off Peak Load LOAD Earth 230V 50Hz Mains Supply Live Supply (Brown or Red) to terminal 1 Neutral Supply (Blue or Black) to terminal 2 Earth (Green/Yellow) to Load Switch Live, Off peak load Primary element (Brown or Red) to terminal 5 Switch Live, Boost load Secondary element (Brown or Red) to terminal 4 Heater Neutral (Blue or Black) to terminal 3 Earth (Green/Yellow) to

6. Commissioning Reverse of the font panel 5 Tariff Table These are pre-programmed times which can be selected and modified.

Contact your energy supplier to check which energy plan you are on, and whether the off peak times change during winter and summer. On the tariff table (located on the reverse of the front panel), find which program collates with your energy plan. Using a terminal screwdriver, turn the program selector to the correct number for the program (if you want a program that is not shown on the table, select the closest one to your desired program and this can be adjusted later). On the back of the unit select GMT ONLY or GMT/BST depending on your energy plan; GMT ONLY fixes the time to GMT. GMT/BST sets GMT over the winter period, and GMT+1 over the summer period. Winter and Summer are displayed according to daylight saving periods regardless of the switch position. 6 Ensure all terminals are secured and screw the front panel of the unit to the back box using the 2 fixing screws previously removed. Operating Modes OFF: With the rocker switch set to OFF, there is no output regardless of the program or boost. The unit can still be programmed and the internal battery will charge. TIMED: With the rocker switch set to TIMED, the output will be according to the program, or the appropriate boost period. Auto will be displayed on the screen in this mode.

Sleep Mode If power is removed the screen will go blank after 10 seconds. The screen will be revived when power is restored. The screen can be woken by pressing any button. The programmes will remain in the memory when power is off. Illumination Press any button to illuminate the screen. The illumination times out automatically 60 seconds after the last button press. The Economy Light illuminates during off peak times. The Boost Button surround illuminates during boost periods. 7 OFF peak times During OFF peak times (selected but the tariff switch) the display will show;

7. Reset Press and hold the + and buttons simultaneously until the screen goes blank. Release the buttons and after a few seconds all of the digits will appear. 8 The factory default settings will now be restored, and the date and time will need re-programming. 8. Setting the current time and date Press the SET button once. The word Clock will be displayed on the top of the screen along with the hour flashing.

Use the + and buttons to set the required hour (when adjusting values, hold the + or button to scroll faster). Press the SELECT button once to save and the minutes will start to flash. Use the + and buttons to set the required minutes and press the SELECT button once to save. The year will start to flash. 9 Use the + and buttons to set the required year and press the SELECT button once to save. The month will start to flash. Use the + and buttons to set the required month and press the SELECT button once to save. The day will start to flash. Use the + and buttons to set the required day and press the SELECT button once to save.

The screen will now show the correct time and season. 9. Reviewing and editing programmes Press the SET button twice. The hour for the ON time will start flash. 10 Use the + and buttons to alter the hour. Press the SELECT button once to save and the minutes will start to flash.

Use the + and buttons to alter the minutes and press the SELECT button once to save. The hour for the OFF time will start to flash. Use the + and buttons to alter the hour and press the SELECT button once to save. The minutes will start to flash. Use the + and buttons to alter the minutes and press the SELECT button once to save. Note: pressing SELECT will either exit to the main screen, or allow you to alter other time periods if they are available on the chosen tariff. If the programs are changed manually away from the pre-set tariff, then MANUAL will be displayed on the screen. 11 10. Manual Boost The BOOST button and screen will illuminate when the boost is pressed. Press the BOOST button once for 30 minutes, twice for 60 minutes or three times for 120 minutes. A forth press will cancel the boost time. Note: The screen will show the remaining time of the boost period. The BOOST button surround is illuminated for the duration of the boost period. The boost is disabled during the economy period. The boost will self-cancel if the economy period starts during a boost period.

11. Programmed Boost Press the SET button three times. The hour for the ON time will start to flash. Use the + and buttons to alter the hour for the ON time. 12 Press the SET button once to save and the minutes will start to flash. Use the + and buttons to alter the minutes and press the SET button once to save. The hour for the OFF time will start to flash.

Use the + and buttons to alter the hour for the OFF time, and press the SET button once to save. The minutes will start to flash. Use the + and buttons to alter the minutes and press the SET button once to save. Press the SELECT button once to exit to the main screen. 13 Activating the programmed boost Press the SELECT button once. Leave for 60 seconds to time out. Press the SELECT button once to cancel. Note: During a boost period the boost button surround will illuminate.

3 Year Guarantee In the unlikely event of this product becoming faulty due to defective material or manufacture within 3 years of the date of purchase, please return it to your supplier in the first year with proof of purchase and it will be replaced free of charge. For the second and third years or any difficulty in the first year telephone the helpline on 020 8450 0515. Note: A proof of purchase is required in all cases. For all eligible replacements (where agreed by Timeguard) the customer is responsible for all shipping/postage charges outside of the UK. All shipping costs are to be paid in advance before a replacement is sent out. 14

If you experience problems, do not immediately return the unit to the store. Telephone the Timeguard Customer Helpline; HELPLINE 020 8450 0515 or email helpline@timeguard.com Qualified Customer Support Co-ordinators will be on-line to assist in resolving your query. For a product brochure please contact: Timeguard Limited. Victory Park, 400 Edgware Road, London NW2 6ND Sales Office: 020 8452 1112 or email csc@timeguard.com www.timeguard.com 67.058.594 (Issue 1) Zerofour November 2017