Stretch More Out of Your Data Centre s Multimode Cabling System

Similar documents
We will look first at the cable, and then the transceivers (which act as both transmitter and receiver on each end of the fiber cable).

Module 11 : Link Design

64G Fibre Channel strawman update. 6 th Dec 2016, rv1 Jonathan King, Finisar

CC-Link IE Controller Network Compatible. CC-Link IE Controller Network Recommended Network Wiring Parts Test Specifications

40G SWDM4 MSA Technical Specifications Optical Specifications

Keyed LC Connector Solution A LANscape Solutions Product

40GBASE-ER4 optical budget

40G SWDM4 MSA Technical Specifications Optical Specifications

Intel Ethernet SFP+ Optics

50 Gb/s per lane MMF baseline proposals. P802.3cd, Whistler, BC 21 st May 2016 Jonathan King, Finisar Jonathan Ingham, FIT

The current state of multimode OTDR and Light Source and Power Meter (LSPM) Insertion Loss (IL) testing is as follows:

Recommended Changes to Optical PMD Proposal

The Road to Single Mode: Direction for choosing, installing and testing single mode fiber

10GBASE-LRM Interoperability & Technical Feasibility Report

Connectix Cabling Systems

SOLO ADSS Short-Span Cables, Fibers

Fibre Channel Fiber-to-Fiber Media Converters

FREEDM Loose Tube Interlocking Armored Cables

Robert Burén. Product Manager. Nexans Cabling Solutions. 10G Solutions

10G SFP+ Modules. 10G SFP+ Module Series

OTS-300 Express Series Power Meters/Sources and Testers

SMF Ad Hoc report. Pete Anslow, Ciena, SMF Ad Hoc Chair. IEEE P802.3bm, Geneva, September 2012

40GBd QSFP+ SR4 Transceiver

Job Aid Server and CSS Separation Avaya S8700 Media Server

50 Gb/s per lane MMF objectives. IEEE 50G & NGOATH Study Group January 2016, Atlanta, GA Jonathan King, Finisar

Pluggable Transceivers Installation Guide

Comparison of options for 40 Gb/s PMD for 10 km duplex SMF and recommendations

EVLA Fiber Selection Critical Design Review

How to Specify MTP Pre-terminated Optical Cabling. January White Paper. Published

FTS-M12G-S85L-55M. SFP 1000Base-SX, 850nm, multi-mode, 550m

DATA SHEET. Two (2) fibers Detachable DisplayPort 1.2 Extender, DPFX-200-TR

100G QSFP28 SR4 Transceiver

XFP 10G 850nm 300M SR SLXF-1085-SR

100G SR4 Link Model Update & TDP. John Petrilla: Avago Technologies January 2013

Introduction to Fibre Optics

DATA SHEET. Two (2) fibers Detachable HDMI 2.0 Extender,

Optical Receiver Manual. Transmitter OP-OR212JSE. Shenzhen Optostar Optoelectronics Co., Ltd (Version 2)

Agilent 83437A Broadband Light Source Agilent 83438A Erbium ASE Source

Arista 40G Cabling and Transceivers: Q&A

MPO Technology Connectivity & Application

Systematic Tx Eye Mask Definition. John Petrilla, Avago Technologies March 2009

Mining and Petrochemical Fiber Optic Cables

RFP LC Uniboot to RFP LC Uniboot Patch cord, 2 fibres, Interconnect tight-buffered cable, LSZH

Prolabs SFP-10G-AOCxM

Next Generation Ultra-High speed standards measurements of Optical and Electrical signals

SPCxxB10100D SFP+ Dual Fiber CWDM CWDM / 10dB / 10 Gigabit Ethernet

XCOM1002JE (8602JE) Optical Receiver Manual

Understanding Multimode Launching Conditions and TIA TSB-178

o-microgigacn Data Sheet Revision Channel Optical Transceiver Module Part Number: Module: FPD-010R008-0E Patch Cord: FOC-CC****

RFP LC Uniboot to RFP LC Uniboot Patch cord, 2 fibres, Interconnect tight-buffered cable, LSZH

Features: Compliance: Applications: Warranty: 49Y7928-GT QSFP+ 40G BASE-SR Transceiver IBM Compatible

SFCxxB16GExD SFP Dual Fibre CWDM ITU CWDM / 16dB / Gigabit Ethernet

INTERNATIONAL TELECOMMUNICATION UNION

SFCxxB24GExD SFP Dual Fibre CWDM CWDM / 24dB / Gigabit Ethernet

DVM-3000 Series 12 Bit DIGITAL VIDEO, AUDIO and 8 CHANNEL BI-DIRECTIONAL DATA FIBER OPTIC MULTIPLEXER for SURVEILLANCE and TRANSPORTATION

Cisco 10GBASE Dense Wavelength-Division Multiplexing SFP+ Modules

SSA Fibre-Optic Extender 160 Fibre Installation Guidelines Version 1.2

FTX-S1XG-S55L-040DI. XFP 10GBase-ER, 1550nm, single-mode, 40km

Critical Benefits of Cooled DFB Lasers for RF over Fiber Optics Transmission Provided by OPTICAL ZONU CORPORATION

Optical Sampling Modules 80C01 80C02 80C07B 80C08C 80C10 80C11 80C12

An Approach To 25GbE SMF 10km Specification IEEE Plenary (Macau) Kohichi Tamura

SPDxx040100D SFP+ Dual Fibre DWDM 100GHz DWDM / 40 km / 10 Gigabit Ethernet

Draka Comteq Presents: The MaxCap multimode Fibre for 10 Gb/s Applications

DATA SHEET. Two (2) fibers Detachable DisplayPort Extender, DPFX-100-TR

Opti Max Nodes Digital Return System

WaveReady WRT Gbps Extended-Reach DWDM Tunable Transponder with XFP Client Interface

200GBASE-DR4: A Baseline Proposal for the 200G 500m Objective. Brian Welch (Luxtera)

INSTRUCTION MANUAL. FiberSaver Series, FS-6000, FS-12000, FS-18000

Cisco 10GBASE Dense Wavelength-Division Multiplexing XFP Modules

QSFP+ 40GBASE-SR4 Fiber Transceiver

CFMFFxxxx-2xx User s Guide Slide-in-Module Media Converter Fast Ethernet, ATM, SONET, or Gigabit

SNS-XFP-10GD-LR 10 Gbps Multi-Rate XFP Transceivers OC192/STM-64, 10GE or 10G FC 1310nm, Single-Mode 10Km, with Digital Diagnostics.

Pre-bid Supplement #01 Communications Specifications and Additional Scope Project Bid: CM Date: 05/26/2017

Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Technical Specifications

Analog HD video over fiber converters for smart HD CCTV

FORWARD PATH TRANSMITTERS

SPECIAL SPECIFICATION 6735 Video Optical Transceiver

100GBASE-SR4 Extinction Ratio Requirement. John Petrilla: Avago Technologies September 2013

ECT5484. Fiber Optic Digital Video, Audio & Data Multiplexer/Demultiplexer. Single Fiber Operation. Specifications

Light Source. Specification & User Manual

100G MMF 20m & 100m Link Model Comparison. John Petrilla: Avago Technologies March 2013

On Figure of Merit in PAM4 Optical Transmitter Evaluation, Particularly TDECQ

100G-FR and 100G-LR Technical Specifications

Optical Receiver Manual. Transmitter OP-OR112R JⅢ. Shenzhen Optostar Optoelectronics Co., Ltd (Version 2)

Part Number Transmitter Output Power Receiver Sensitivity Reach Temp DDM RoHS. Logic Symbol Name/Description Note 1 - GND Module Ground 1

from ocean to cloud ADAPTING THE C&A PROCESS FOR COHERENT TECHNOLOGY

Overcoming Nonlinear Optical Impairments Due to High- Source Laser and Launch Powers

DATA SHEET. 32 x 32 DVI / HDMI /SDI Matrix, OMM Contents. OMM-2500 (Ver. 1.0)

500 m SMF Objective Baseline Proposal

Fiber Optic Testing. The FOA Reference for Fiber Optics Fiber Optic Testing. Rev. 1/31/17 Page 1 of 12

COE Group plc. Contents

100G PSM4 & RS(528, 514, 7, 10) FEC. John Petrilla: Avago Technologies September 2012

GIGALIGHT 300m XFP Optical Transceiver GX SRC

Instalaciones de fibra optica en entornos de centro de datos y campus para suportar 40, 100G y mas

RFP LC Uniboot to RFP LC Uniboot Patch cord, 2 fibres, Interconnect tight-buffered cable, LSZH

FIBRE CHANNEL CONSORTIUM

Small Form-factor Pluggable (SFP) Optical Module Cartridges (Ethernet) For Densité Frames and Grass Valley/Telecast Standalone Fiber Products

CFPQD010C10D CFP Dual Fibre 1310nm* / 10km / 100GBASE-LR4 & OTN OTU4

The need for Encircled Flux, real or imaginary?

Product Specification 100m Multirate Parallel MMF 100/128G QSFP28 Optical Transceiver FTLC9551SEPM

Transcription:

Stretch More Out of Your Data Centre s Multimode Cabling System 1. Introduction: Multimode fibre remains the preferred economic cabling media in the data centre due to its advantage of utilizing relatively inexpensive transceivers over short (<20m) or long (>120m) links in the data centre. While multimode fibre is economically preferred, it may be considered to have limitations for very long links (>300m) and for channels requiring several connections (increased insertion loss). In this paper, we will explore the possibility of pushing beyond the standard limits for channel length and loss. An Analogy Demonstrating the Interdependence of Attenuation and Bandwidth Before the words in this article can be interpreted by the brain, the black-curved and straight-lined shapes (letters) must be recognizable. In order for that to happen, there are two fundamental requirements: the letters must be illuminated enough so that they reach the sensors in the eye, and the image must be focused so that the brain can recognize the shape. Consider this three-part analogy: 1) think of the letters as analogous to light pulses in a fibre (information), 2) the eye s dependency on light intensity, like the receiver s sensitivity and the influences of signal attenuation (signal strength) and 3) the focus or blurred image of the letter like the resultant signal at the receiver with distortions related to bandwidth limitations (signal purity). Descriptive Context Fibre Optic Receiver World Analogous Equivalent in the Eye s World e Original Information Light pulse Letter Element Influence of Signal Attenuated pulse Dim/faint letter Strength (Attenuation) Influence of Signal Pulse shape, distorted Blurry letter, distorted Purity (Focus/Bandwidth) by fibre system by focus limitation of eye bandwidth limitation After having excellent eyesight for most of my life, at the age of 45, I now suffer from far vision (can t focus on things that are too near; i.e., I need reading glasses). I first noticed this when trying to determine the recording date of an album/song by reading the copyright dates on CDs. I needed to move the CD away from my normal reading distance before the text was in focus. More recently related to my work, I suffer from can t get the fibre in the hole syndrome, when working with various fibre connector or tubing products. Some of the focus problems can be compensated with a brighter light source (headlamp). However, there is a limit to what an increase in light can do to compensate for the focus problem. Alternatively to increasing light, I may need to move the object in order to move it to the proper focal point (as I did with the CD case). As any of you with farsightedness know, the solution to being able to see is one of the following: 1) Adjust the light level and distance between your eyes and the object until you find your ideal operating point and can see clearly. 2) Buy glasses! Just as there is a relationship between the light intensity and focal distance of your eyes, there is also a relationship between the decreased signal strength (mostly due to insertion loss of connectors and fibre) and distance limitation (mostly due to bandwidth) of a fibre, especially at increasing transmission speeds. And few solutions: 1) Increase the strength of the light pulse and/or decrease the distance between the source and receiver until you find the ideal operating point. 2) Upgrade your system! e LAN-1475-A4-BEN Page 1

The relationship between light and focus when reading is not linear. There is a point where the light level is so low that even if the text is within my window of focus, I cannot see the shapes. Equally, if the lighting is ideal, but the text is not in my window of focus, I will not be able to read the printed text. In order for an optical receiver to interpret light pulses in a G optical link, we must ensure that the light intensity and focus relationship remains in the ideal operating point. As with the aging eye, the aging transceiver also succumbs to poorer performance over time, which is more significantly influenced by bandwidth and loss than in its early years. The IEEE model simulates several parameters and the subsequent ability of a receiver to interpret the light pulses passing through a fibre. Corning has run the same model with improved parameters and Corning passive components in the system, which allows one to have confidence for designs which go beyond the conservative IEEE model parameters and allows for extended reach (longer links) or higher channel loss (more connections) solutions. This article provides an in-depth look at the model and the Corning De-Rating Tables output so that system designers can find the ideal operating points and real limits for their networks. 2. Background/Motivation: We see a step-change increase in the transmission speeds of LAN and SAN protocols about every five to seven years, as seen in Table 1. But system designers are typically forced to reduce channel length and channel loss for the benefit of the increased speed. The standards employing multimode fibres, such as Ethernet 3 and Fibre Channel 5 usually define a maximum channel loss for a maximum length. These standards do not provide options for channels of higher loss or longer distances other than those stated for a given multimode fibre type. Table 2 summarizes the maximum length and channel loss limits for several of the commonly used protocols running on multimode fibre in the data centre. If armed with the proper design tools and high-performance cabling components, one can exceed link length or channel loss limits and still achieve full transmission speeds. 1Gbps Ratified 1998 Millions of Ports 30.00 25.00 20.00 15.00.00 First Shipments Gbps Ratified 2003 First Shipments 40/0Gbps Ratified 20 5.00 0.00 2017 2016 2015 2014 2013 2012 2011 20 2009 2008 2007 2006 2005 2004 2003 2002 2001 2000 Table 1: Number of Servers Supporting Ethernet Speeds and Ratification Date Compared to Presence in Market LAN-1475-A4-BEN Page 2

Application (with 850nm VCSEL) OM3 Max length [m]/ Attenuation [db] OM4 Max length [m]/ Attenuation [db] 1GbE 10* / 4.1 10* / 4.5 GbE 300 / 2.6 400 / 2.71 40/0GbE 0 / 1.9 150 / 1.5 4GB Fibre Channel 380 / 2.88 400 / 2.95 8GB Fibre Channel 150 / 2.04 190 / 2.19 16GB Fibre Channel 0 / 1.86 125 / 1.95 Table 2: Maximum Channel Length/Insertion Loss for Common Protocols * OM3/4 not defined for 1G in IEEE 3. Model: This discussion focuses on the IEEE (Institute of Electrical and Electronic Engineers) requirements for Gbps Ethernet transmission, defined in GBase-SR 3 (Gbps over multimode fibre using 850nm VCSEL). Although focusing on the G standard, the logic of the discussion also applies to the 40G and 0G Ethernet and the Fibre Channel standard limits. The single operating point defined in the G standard for OM3 fibre (300m/2.6dB) is derived from the G Base-SR (G Ethernet) physical media transmission model from IEEE 2. This model is based on multiple parameters including but not limited to fibre loss, connector insertion loss, fibre bandwidth, dispersion, source spectral width, source centre wavelength, modal noise penalties and receiver sensitivity. The IEEE model used to simulate Ethernet operation and the Fibre Channel Physical Interfaces 5 (FC-PI-5) endorsed model for 8GFC and 16GFC Fibre Channel analyse a myriad of parameters (some listed above) and predict several output parameters and the resulting eye diagram of such a system. Basically, the models confirm that the received signal for each protocol is of adequate quality, given the transmitted signal conditions and the worst-case distortions that may occur before it arrives at the receiver. There is a trade-off between channel length and loss. If we reduce our system length, we can gain back some margin (in db) in the form of more connections and still receive a good signal. The question is: what is the relationship of channel loss to channel length? Unfortunately, it is not linear. Therefore, we need the model as an aid to confirm that relationship. A screenshot of the modeling tool for IEEE GBase-SR is shown in Figure 1. Figure 1: Modeling Tool Used for IEEE 802.3ae, GBase-SR LAN-1475-A4-BEN Page 3

4. Concept of the Corning De-Rating Tables: The values used in the IEEE G-Base-SR model assume worst-case parameters for the performance of the components in the link, including transmitters, physical media cabling and the receiver. Typically, the published standard considers conservative values for these parameters and only provides one operating point of distance and insertion loss, which is a snapshot, as shown in Table 2. Corning Cable Systems offers passive products with higher performance parameters than those assumed in the standard model. Corning De-Rating tables provide a matrix of operating distances and channel losses like those shown in Table 2. Consider that Corning products provide consistently better performance (specifically fibre loss, fibre bandwidth, connector insertion loss) than those used in the standard model. Additionally, instead of listing the single, snapshot view provided in the standard, the Corning De-Rating Tables give the designer a complete set of detailed images relating the distance and insertion loss trade-off, while ensuring a quality signal arrives at the receiver, as verified by the IEEE model. There is a nonlinear relationship at play with the trade-off between channel loss and channel length. The values in Corning De-Rating Tables are derived using the same IEEE model as the standards derived values. This model considers the non-linear relationships among all of the parameters of the system. Additionally, the Corning De-Rating Tables provide a series of ideal operating points for links of a specific fibre type. This is helpful for system planners who have links that do not fall within the IEEE default maximum length/maximum loss limit, like 2.6dB/300m for GbE running on OM3 fibre. A planner wants the confidence that the link will work over a variety of channel conditions, and the Corning De-Rating Tables provide that assurance. 5. Supporting methodologies using this concept: While some readers may have questions when first learning about de-rating tables, this concept is not unique to Corning; the de-rating table form has been embraced by the standards bodies. In CENELEC s Information technology - Generic cabling systems. Part 5: Data centres (EN50173-5) 4 and Fibre Channel s Physical Interfaces 5 (FC-PI-5), we no longer find the single data point of length and channel loss, which provides inflexible design guidance for passive cabling, as shown in Table 2. Instead, we find the de-rating tables have been adopted, based on the influence of additional connector loss on the channel length. The result is a matrix within the standards, which offers a range of length/channel loss combinations. With these length/loss combinations, a data centre designer can more freely and confidently design a network without feeling locked in to the perceived limits of the standards. 6. How to use the Corning De-Rating Tables: A Ethernet Ethernet Distance Capability and Channel Insertion Loss 12-fiber MTP Connectivity Corning Cable Systems Number of MTP Connections LANscape Solutions Data Distance [m]/channel Loss [db] B Cabled Fibre Category Rate - Core/Cladding [Gb/s] Dimensions in µm C 2 3 4 5 6 D OM3 (50/125) 1 40 / 0 10 / 4.14 320 / 3.45 150 / 1.18 00 / 4.68 320 / 3.45 140 / 1.44 00 / 4.68 320 / 3.01 120 / 1.65 00 / 4.68 320 / 3.01 5 / 1.88 950 / 4.89 320 / 3.01 90 / 2.09 E Table 3: Corning De-Rating Table for Ethernet and Corning OM3 Fibre LAN-1475-A4-BEN Page 4

Let s get familiar with to the table s main areas: A: The header of the table indicates the protocol for this table. The protocol options are Ethernet or Fibre Channel. B: The first column indicates the fibre category for which the values in the table apply. Currently, the fibre category options are OM3 and OM4, based on Corning s standard Ultra-Bend multimode fibres. C: The second column indicates data rate. The data rates available are related to those currently defined by the respective protocols indicated in A. D: This row indicates the number of MTP connections in the channel. Figure 3 provides examples of an MTP connection. The connection may be an MTP to MTP connection or an MTP to MTP module (cassette) connection. Both MTP connections are considered equivalent in the context of the Corning De-Rating Tables and the associated loss. We do not assume a worst-case MTP Connector loss but instead a connector loss based on statistical distributions of Corning product. E: The two values within the cells indicate the maximum channel length in meters and the allowable loss of the link in decibels. This is not the traditionally calculated link-loss budget using worst-case values for fibre and connectors. In the example highlighted above, we want to confirm the channel limits for an Ethernet Gbps channel using Corning OM3 fibre, with Corning s Pretium EDGE products in a link, which has four MTP connections. The table indicates that we can successfully operate G-Base SR link up to 320m with a maximum allowable loss of 3.01dB. Note that 3.01dB is the maximum allowable channel loss and not the budgeted link loss, which is normally calculated using worst-case values for connector loss and fibre loss. The Corning De-Rating Table maximum allowable loss includes unallocated margin, which is not associated with any passive component or power penalty. The length for GbE data in Table 3 remains constant for all combinations of two to six MTP connections. This seems illogical as one expects an increase in the channel loss with the increase in number of connections, which should consequently impact (decrease) the channel length. However, when using Corning product with higher bandwidth and lower connector loss, the IEEE model indicates the allowable channel length limit remains constant. Remember, the Corning De-Rating Table indicates the maximum allowable distance-loss relationship; for this distance (320m), there is limited PENALTY caused by the relatively low incremental insertion loss associated with adding up to six connections. The limitation in this case is driven mainly by the power penalties associated with the inter-symbol interference, which is a function of bandwidth. The limitation at 1G and 40/0G is driven by both insertion loss and bandwidth, as we see a decrease in length as the connectors (and associated channel loss) increase. When I was young, I could read small text close or at a far distance in dim or bright lighting. My ability to interpret the words on the page was constant across a large range of distances and light levels. There was effectively no penalty for changing the location of the text. Conversely, as I ve aged and my eye sensitivity has deteriorated, I have a restricted range of vision, which is significantly affected by small changes in distance or light. Similarly, a restricted system with poor bandwidth and channel loss will experience significant changes when the length is varied. A system composed of higher-performance passive components will be less susceptible to the limitations caused by the active devices. LAN-1475-A4-BEN Page 5

Figure 2: MTP Connection in Modular Plug & Play System Figure 3: MTP Connection in Parallel Optics System Regardless of the system, the MTP connection is considered equivalent when using the Corning De-Rating Tables. For both systems above, there are four MTP connections. LAN-1475-A4-BEN Page 6

7. Conclusions The Corning De-Rating Tables offer planners an alternative to the fixed maximum operating points found in the IEEE and Fibre Channel standards (Table 2). The tables provide a set of operating points for the channel (length/loss) in which a system can operate based on fibre type, data rate and number of connections. While the Corning De-Rating Tables provide insight into what can be attained with a system, the maximum lengths defined in the standards and those guaranteed by the active component manufacturers typically correspond to the limits shown in Table 2. However, with unexpected challenges, planners must consider channels that exceed the limits defined in the standards. The Corning De-Rating Tables allow a planner to confirm that a multimode cabling design may be stretched beyond the defined standard limits. The values in the Corning De-Rating Tables are derived using the IEEE model, which considers the relationship among all the relevant parameters of the system but with parameters based on typical values found in Corning s products (dispersion, bandwidth, insertion loss, etc.). In evaluating the inter-dependencies of these many parameters, the Corning De-Rating Tables have been developed to provide a series of operating points for channels of a specific fibre type utilising Corning product. This is helpful for system planners who have links that do not fall within the IEEE single-reference point (maximum length/maximum loss). A planner wants the confidence that a link will work if operating outside this single-value limit provided by the standard. Other applications of the Corning De-Rating Tables include system design with optical splitters, which introduce significant loss, possibly exceeding the limit defined by IEEE. Although the discussion and examples presented are focused on G Ethernet, the concepts apply to Fibre Channel and the transmission speeds listed in the table, including parallel optics. If you have any further questions, please contact a Corning Cable Systems Representative or send email requests to EMEA.AE@corning.com. Fibre Channel Corning Cable Systems LANscape Solutions Cabled Fibre Category - Core/Cladding Dimensions in µm OM3 (50/125) OM4 (50/125) Fibre Channel Distance Capability and Channel Insertion Loss 12-fiber MTP Connectivity Number of MTP Connections Data Distance [m]/channel Loss [db] Rate [Gb/s] 4 8 16 4 8 16 2 3 4 5 6 500 / 2.27 480 / 2.43 440 / 2.62 420 / 2.78 380 / 3.04 215 / 1.40 205 / 1.62 190 / 1.91 180 / 2.08 165 / 2.32 320 / 3.45 320 / 3.45 320 / 3.01 320 / 3.01 320 / 3.01 140 / 1.17 130 / 1.45 115 / 1.65 0 / 1.95 90 / 2.11 2 3 4 5 6 600 / 2.64 580 / 2.78 540 / 2.86 500 / 3.08 480 / 3.18 270 / 1.59 260 / 1.77 235 / 2.00 220 / 2.20 205 / 2.38 485 / 2.45 485 / 2.45 470 / 2.89 470 / 2.89 465 / 3.25 185 / 1.38 175 / 1.59 155 / 1.78 140 / 2.00 125 / 2.18 LAN-1475-A4-BEN Page 7

Ethernet Corning Cable Systems LANscape Solutions Cabled Fibre Category - Core/Cladding Dimensions in µm OM3 (50/125) OM4 (50/125) Ethernet Distance Capability and Channel Insertion Loss 12-fiber MTP Connectivity Number of MTP Connections Data Distance [m]/channel Loss [db] Rate [Gb/s] 1 40 / 0 1 40 / 0 2 3 4 5 6 10 / 4.14 00 / 4.68 00 / 4.68 00 / 4.68 950 / 4.89 320 / 3.45 320 / 3.45 320 / 3.01 320 / 3.01 320 / 3.01 150 / 1.18 140 / 1.44 120 / 1.65 5 / 1.88 90 / 2.09 2 3 4 5 6 10 / 4.51 10 / 4.51 50 / 4.76 50 / 4.76 00 / 4.97 485 / 2.45 485 / 2.45 470 / 2.89 470 / 2.89 460 / 3.25 185 / 1.25 170 / 1.50 135 / 1.71 125 / 2. 115 / 2.18 Table 4: Complete Corning De-Rating Tables for Fibre Channel and Ethernet Operating with Corning Cable Systems Ultra-Bend OM3 and OM4 Fibres and Low-Loss MTPs * Maximum allowable channel loss References 1. Doug Coleman, Corning Cable Systems, representative to Fibre Channel Industry Association 2. Review of the Gigabit Ethernet Link Model, White Paper, Authors: D. Cunningham, P. Dawe, Agilent Technologies, ONIDS 2002 3. Part 3: Carrier Sense and Multiple Access with Collision Detection (CSMA/CD) Access Method and Physical Layer Specifications Amendment: Media Access Control (MAC) Parameters, Physical Layers, and Management Parameters for Gb/s Operation, IEEE Standard 802.3ae, IEEE Computer Society, August 30, 2002. 4. EN50173, Chapter 5: Information technology - Generic cabling systems Part 5: Data centres, CENELEC, 2002 5. Fibre Channel Industry Association Corning Cable Systems LLC PO Box 489 Hickory, NC 28603-0489 USA 800-743-2675 FAX: 828-325-5060 International: +1-828-901-5000 www.corning.com/cablesystems Corning Cable Systems reserves the right to improve, enhance and modify the features and specifications of Corning Cable Systems products without prior notification. LANscape, Pretium and Pretium EDGE are registered trademarks of Corning Cable Systems Brands, Inc. Plug & Play is a trademark of Corning Cable Systems Brands, Inc. MTP is a registered trademark of USConec, Ltd. All other trademarks are the properties of their respective owners. Corning Cable Systems is ISO 9001 certified. 2013 Corning Cable Systems. All rights reserved. Published in the USA. LAN-1475-A4-BEN / April 2013 LAN-1475-A4-BEN Page 8