Sensor module. Safety instructions. Function Correct use. Product characteristics. Structure of the device. Operation. Ref.No.

Similar documents
Operating Instructions Dimmer for V Incandescent Lamps

Figure 1: Device components

1 Safety instructions. 2 Device components. 3 Function. Light Management Relay switch insert 2-channel. Art.-No.: 1202 URE.

System 2000 System 2000 HLK relay insert. 1 Safety instructions. 2 Device components. 3 Function. Order No. : Operating instructions

Operating instructions. Universal timer switch display

EC5415B. B-Tronic EasyControl. Assembly and Operating Instructions. Wall/hand-held transmitter, 15-channel, bidirectional

KNX / EIB Product Documentation. DALI Gateway. Date of issue: Order no Page 1 of 136

Operating Manual. Basic Control BC16. two-channel for eco moon

Dimming actuators GDA-4K KNX GDA-8K KNX

Dimming actuators of the FIX series DM 4-2 T, DM 8-2 T

(1) (2) (3) Bedienungs- und Montageanleitung. Safety instructions. Structure of the device

Tectiv 220 Instructions for use

INSTRUCTIONS FOR USE Pro-Ject Receiver Box S

Operating instructions III / 2004

Mosaic TM Dimmer 3 x 1000 W

Luminaire installation box Surface-mounted box Ceiling installation box

Timer Modules. MEU11 24 Hour Module, MEU17 7 Day Module (Without Housing)

ArteorTM Dimmer 3 x 1000 W / /60

INSTRUCTIONS FOR USE Pro-Ject Tuner Box S

LED DRIVERS. LQC4D-V1 4 channels. User Manual FEATURES

RADIO RECEIVER RGBW CONTROLLING LED STRIP COMMON ANODE

Tempus Lux Digital Photoelectric Switch D GB CZ BZT Installation and operating instructions BZT27731

Instruction manual. DALI Gateway art Installation manual

DLP200M 2 Relay Module for Heating and Cooling Plants

Electrical connection

INSTALLATION & OPERATING INSTRUCTIONS SINGLE/TWO CHANNEL 24HR/7 DAY TIMER. Cat No. TR671/TR672TOP

Ordering data. Type Inputs Outputs Dimming switch Motion sensor DSI signal2 Digital control line DSI Control output per physical output (devices)

Commander 384. w w w. p r o l i g h t. c o. u k U S E R M A N U A L

Schneider Industries SAS MTN5812../MTN MTN Time switch

Aspect 2 Circuit Digital Scene Control

Assembly. Front view. LEDs. Parametrization interface. Power Bus

4.0 Description. 2-channel operation D1 and D2 rated at 200 VA each. 1-channel operation D1 rated at 400 VA (see connection chap. 6.

Smart Control SC16 3-Channel for matrix

DLP600M 6+1 Relay Module for Heating and Cooling Plants

INSTRUCTIONS FOR USE Pro-Ject Tuner Box S2

Product information. Front-door station series with video for surface-mount

LINK-RAY TM MODULATORS FOR CONSTANT- VOLTAGE. LinkRay Modulators 12 V / 24 V Constant-voltage Applications MODULATORS

KNX 1-10V dimmer 4 channels

SceneStyle2 User Guide

KNX Dimmer RGBW - User Manual

12months. on-site warranty. DZE ELECTRONIC PRESSURE SWITCH for detection of overload per EN 81 2 featuring two adjustable switching points

Gamma instabus. Technical product information

M150SP USER S AND INSTALLER S MANUAL. v2.0 REV. 03/2017

Datasheet - SRB301LC 24VAC/DC

Dimensions. Model Number. Electrical connection. Features. Pinout Product information. Indicators/operating means. LGS25 Serie.

Product Manual. Designed and Manufactured in the UK by Optikinetics

120cm (4x36 Watt) incl. Splitter Instruction Manual

Datasheet - SRB-E-201ST

Technical data. General specifications. Indicators/operating means

Solid-State Digital Timer

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area

Weekly Time Switch. Rated time Time setting range Time division 24 hrs x 7 days 00:00 to 23:59 1min

16 Amp Electronic 24 Hour/7 Day Time Controller

KNX Technical Reference Manual Busch-EnergyControl

Your Global Automation Partner. Ultrasonic Sensors. Operating Instructions

Radio receiver EXL. 4-channel / up to 1000 memory locations. Mounting and operating instructions for qualified electricians

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

For installation queries contact Customer Services (0) TCR IP 4 Operating instructions

Operating instructions Retro-reflective sensor. OJ50xx laser / / 2010

2CKA001473B KNX Technical Reference Manual ABB i-bus KNX. KNX LED dimmer Constant voltage 4gang with power adaptor 6155/40-500

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

Tebis application software

FX-2DA SPECIAL FUNCTION BLOCK USER'S GUIDE

K-BUS Dimmer Module User manual-ver. 1

FD Trinitron Colour Television

Re:connect M 203. RS232 Interface Revox. Dominating Entertainment. Revox of Switzerland. E 2.03

MINI MCR-SL-F-UI-NC. Frequency transducers. Data sheet. 1 Description

SHUTTLE WITH INFRA-RED DETECTION SAS2-IR

Linear flow controls VFC Linear flow controls with actuator IFC

Owner's Manual DIGITAL TO ANALOG BROADCAST CONVERTER WITH REMOTE CONTROL. Model: CVD508 PLEASE READ BEFORE OPERATING THIS EQUIPMENT.

talento 800 Series 365-Day One, Two and Four Circuit Electronic Time Controls Functional Description

Product Manual. ABB i-bus EIB / KNX Switch/Dim Actuators SD/S. Intelligent Installation Systems ABB

CAMTO LTD. Arc detecting system DC/AC

STD800LED Large display panel for photovoltaic systems

of Switzerland of Switzerland Re:source FM Tuner Module Dominating Entertainment. Revox of Switzerland.

TRANSCENSION 6-CHANNEL DMX DIMMER PACK (order code: BOTE40) USER MANUAL

Capacitance Limit Detection nivotester FTC 420/421/422

AK-PVE4 Operating Instructions. Measuring of norm signals in wall-type units. Performance:

Operating instructions Through-beam sensor. OJ51xx laser / / 2010

ACCESSORIES MANUAL PART NUMBER: PRODUCT REVISION: 1 PNP202. Interconnect Box USER'S GUIDE

LUNA 129 star-time

ES-Mega MegaBeans. Access Control System. User Manual. People in Motion

Passive UTP Transceiver Hub with Integral Camera Power Installation Guide

TeleHawk Door entry system

GESTRA Steam Systems NRR 2-50 NRR English. Installation & Operating Manual Level Controller NRR 2-50 Level Controller NRR 2-51

POINTS POSITION INDICATOR PPI4

Standard signal metering in wall-mounting case

Operating instructions Electronic preset counter Type series 717

CH1 CH2 CH3 CH4. Master /Fade CH5. 600s CH6. 60s SC1 SC2 SC4 SC3 SC5. SC6 Off/Pro. AL Fade 6 Pro. User guide

KONTROL channels DMX controller USER MANUAL. For safety, please read this user manual carefully before initial use.

4 Wiring Brochure Wiring and installation of specific control

of Loewe E 2.10_m1 1

Tebis application software

STX Stairs lighting controller.

of Switzerland FM Tuner MK2 E 2.01

Level Measurement silometer FMC 420, FMC 423

ENGLISH (BioKey - IR Modus with Remote Control)

Operating Instructions. Room temperature controller with clock

of of Re:connect M 203 Pioneer Interface Dominating Entertainment. Revox of Switzerland. E 2.03

Operating instructions Capacitive level sensor KNQ

Transcription:

Sensor module Ref.No.: SM 1608 V03 Safety instructions Caution! Electrical devices may only be installed and fitted by electrically skilled persons. Non-compliance with the installation information could cause damage to the device, fire or other hazards. Connect the module exclusively to the universal relay or dimming station (no mains potential!). To fasten radio to the supporting ring, only use the enclosed plastic screws. These instructions are a component part of the product and must remain with the end customer. Function Correct use Operation of consumers, e.g. light on/off, dimming, blinds/shutters up/down, calling up and saving light scenes etc. Connection to relay station or dimming station Installation in appliance box according to DIN 49073 Product characteristics Up to 16 load outputs of the relay or dimming station can be controlled. Switching, contact, dimming, blind/shutter Light scenes: up to 4 light scenes per control point can be freely configured. Central function: all assigned load outputs are switched on/off centrally. Free assignment of the sensor surfaces to the load outputs, central functions and light scenes Possible to change settings LED can be used as feedback and as orientation light Feedback of switching states on all connected sensor modules. LED brightness adjustable in 3 stages (100 %, 50 %, off). Up to 4 sensor modules can be connected to a single relay/dimming station, even with stations connected in parallel. Cloning: transfer of a set assignment to another sensor module. If mains power fails, assignments are retained. Easy installation through 2-wire cable. Can be labelled using JUNG labelling tool. Structure of the device 2 x (5) 2 x (2) (1) (2) (3) (4) (5) (6) (7) (1) Supporting ring (2) Box screws (3) Frame (4) Sensor module (5) Plastic screws (6) Insert for labelling (7) Cover Fig.1.: Structure of the device Operation Operation is through touching the respective sensor surface (button). Operating blind/shutter Move blind/shutter: press and hold button Stop or adjust blind/shutter: press button briefly

Operating light (relay station) Switching: press button briefly (toggle mode) Operating light (dimming station) Switching to switching-on brightness: press ON button briefly Pressing and holding the OFF button switches to minimum brightness. Pressing and holding the ON button switches on and dims to maximum brightness. Switching the light scene Press button briefly The light scenes switch the outputs in sequence. In the light scenes, the dimming station switches to switching-on brightness only from the switched-off state. Information for the electrically skilled person Installation and electrical connection DANGER! Electric shock from touching live parts in the installation environment. An electric shock can be fatal. Before working on the device, disconnect the power and cover live parts in the area! Supporting ring side A for flat design Supporting ring side B for LS range. Install supporting ring (1) in the right orientation on a flush-mount appliance box (designation TOP = above; Type A or Type B forwards) Only use supplied box screws (2). Set frame (3) on the supporting ring. Connect sensor module (4) with the station and set onto the supporting ring. Connecting terminal downwards! Only fasten the sensor module to the supporting ring with the enclosed plastic screws (5). Only tighten the plastic screws lightly (!). Snap the cover (7) with inserted inscription label or photo (6) onto the sensor module. Snap fastening on side of cover. DANGER! When installing with 230 V devices under a common cover, e.g. socket outlets, there is a danger of electric shock in the event of an error! An electric shock can be fatal. Do not install any 230 V devices in combination with a push-button sensor expansion module under a common cover! A1 A2 A3 A4 MODE A5 A6 A7 A8 ON/n OFF/o 24 V SELV - + - + 24 V SELV A1' E1 A2' E2 A3' E3 A4' E4 A5' E5 A6' E6 A7' E7 A8' E8 - + - + - + Fig.2.: Connection of max. 4 sensor modules to the relay or dimming station. Pay attention to polarity Before setting parallel mode on the second station, the sensor module must be connected. Otherwise parallel mode will not be recognised. Start-up In the state as delivered, the buttons (sensor fields) are allocated and the station outputs are assigned. - +

A1 A1 A2 A2 A1 A2 A3 A4 A3 A3 A4 A4 A5 A6 A7 A8 A5 A5 A6 A6 A9 A10 A11 A12 A7 A7 A8 A8 A13 A14 A15 A16 Fig.3.: Button assignment for connection to one station A1-8 and to 2 stations operated in parallel A1-16 The operation mode of the load outputs must be selected on the relay station in correspondence to the requirement (contact, switching, blind). The operation mode cannot be set on the sensor module. Preliminary remark to programming The program is called up by entering a 4-digit button combination twice. Preliminary remark to grouping (button 1) Assigning the relay or dimming station outputs to the buttons on the sensor module. Up to 16 buttons can be assigned to a single output. Relay station: toggle mode. The output is switched on or off through the same button. In blind/shutter mode, one channel for moving up and one channel for moving down are assigned. Dimming station: each load output is assigned 2 channels. Example: Load 1 switches on and dims brighter, channel 2 switches off and dims darker. Preliminary remark to central function (button 2) Central OFF and central ON can be assigned independently of each other. Channels which should respond to the central function are set at the stations. In the state as delivered, all channels respond to the central function. Preliminary remark to light scene (button 3) Before setting the light scene, the station must be set through button 6. Switching several outputs with one button. Switching states are assigned to the outputs. 4 light scenes per control point are available. Preliminary remark to LED brightness (button 4) The LED brightness can be set for the switched-on and switched-off states. Preliminary remark to tone (button 5) Feedback tone when sensor module is actuated. Preliminary remark to stations (button 6) Indication of which stations, relay or dimming station, are connected. Programming Entering a 4-digit button combination brings you to the programming level. The sensor module must be connected to the station. In the following, sensor surfaces are designated as buttons. Programming mode from state as delivered or after reset No change on the sensor module has taken place yet. When grouping, central function or light scene are selected, all pre-set groupings are deleted. All surfaces can be reassigned. When LED brightness or tone is selected, the preset links are retained even when no changes have been made and the area is left directly through button 16. Changing the links Settings that have been made can be changed in the respective area. Programming level

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Fig.4.: Numbering the buttons No switching commands are executed in the grouping mode. Press buttons 6 3 5 5 in sequence (Figure 5). All LEDs fl ash 2x. Press buttons 6 3 5 5 in sequence once again. All LEDs fl ash 2x. LEDs 1 to 6 light up. The selection level is active (Figure 5). 1 2 3 4 5 6 Fig.5.: LEDs 1-6 light up Button 1: grouping Button 2: central function Button 3: light scene Button 4: LED brightness Button 5: tone on/off Button 6: stations Button 1: Setting or changing the grouping During the assignment, fi rst a load output (1-8 or 1-16) is selected, then the buttons which should switch the load output. The dimming stations are assigned 2 channels for each load output. Example: Load 1 switches on and dims brighter, channel 2 switches off and dims darker. Buttons 1-6 light up. Press button 1 (Grouping). The link mode Grouping is active. LEDs of switch outputs that have not yet been assigned fl ash; assigned LEDs light continuously. Select load output, press button. Other buttons assigned to load outputs light up 50 %. Free buttons are off. Select the buttons that should switch the load output. The selected buttons fl ash. Any buttons can be selected. i Buttons that are already allocated can be assigned to the active channel by pressing. The existing links are overwritten during saving. The LEDs of these buttons fl ash 50 % - 100 %. Pressing again establishes the previous selection. To save the link, press and hold button 16 for approx. 3 seconds. Return to load output selection. LEDs of load outputs that have not yet been assigned fl ash, LEDs of assigned load outputs light continuously. For additional links, select fl ashing button. Back to selection level: press and hold button 16 approx. 3 seconds. End selection level, press and hold button 16. Longer acknowledge tone

Button 2: Setting or changing the central function When assigning the central function, button 1 for central ON or button 2 for central OFF are selected, then the buttons which should switch the central function. It is also possible to assign only central ON or central OFF. 1 2 Fig.6.: Installation Buttons 1-6 light up. Press button 2 (central function) The link mode Central function is active. Button 1: central ON Button 2: central OFF Free central function lights up Assigned central function flashes Select central function, press button Other buttons assigned to switch outputs light up 50 %. Free buttons are off. Select free buttons which should switch the central function. The selected buttons flash. Any free buttons can be selected. Pressing a flashing button again cancels the selection. The button is off. To save this link, press and hold button 16 for approx. 3 seconds. Back to central function selection. LED of central function that has not yet been assigned flashes, assigned lights up. For additional links, select flashing button. To change an existing central function, select the lit button. Back to programming level: press and hold button 16 approx. 3 seconds. End programming level: press and hold button 16 approx. 3 seconds. Flashing of all LEDs indicates acknowledgement. Button 3: Setting or changing the light scene Before setting the light scene, the station must be set through button 6. Status feedback to the stations must be active. When the light scene is assigned, first one of the total of 4 light scenes is selected. Next assign the switching state of the load outputs, then the buttons which should switch the scene. The outputs switch the set light scene with a short delay. 1 2 3 4 Buttons 1-4 flash. Press button 3 (light scene). The link mode Light scene is active. LEDs 1-4 represent the light scenes 1-4. Fig.7.: Light scenes 1-4

Free light scenes flash, assigned light scenes light continuously. Select a light scene button 1-4. One LED lights up for each connected load output (1-8 or 1-16). The switching state of the respective load output is set by buttons. LED channel LED ON: LED flashes slowly: LED flashes quickly: LED OFF: Load Current status is retained. Channel switches on (switch channels on relay station and switching-on brightness on dimming station). Duration command for blind/shutter and dim function. Move blind/shutter to end position; dimmer dims to max. or min. brightness. Channel switches off. The dimming station switches the load at output 1 with channel 1 on and channel 2 off. For light scenes, the following settings for output 1 apply: LED button 1 LED button 2 Light ON ON Current status is retained LED flashes slowly LED flashes quickly ON ON ON LED flashes quickly ON OFF off Switching-on brightness Maximum brightness Minimum brightness During display of the light scene, the outputs at the station correspondingly switch with delay. Light scenes must not be assigned to button outputs. All load outputs have been set. Press and hold button 16 Buttons assigned to other switch outputs light up 50 %. Free buttons are off. Select free buttons. The selected buttons flash. To save this light scene, press and hold button 16 for approx. 3 seconds Return to light scene selection LEDs 1-4: free light scenes flash, assigned light scenes light continuously. For additional light scenes, select flashing button. To change an existing light scene, select the lit button. Back to selection level: press and hold button 16 approx. 3 seconds. End selection level, press and hold button 16 Flashing of all LEDs indicates acknowledgement. Button 4: LED brightness All LEDs are set in sequence. Touching the respective LED changes the flashing. The blinking signals the LED bright-

ness in the switched-on and switched-off states. Press button 4 (LED brightness) The link mode LED brightness is active. Assigned buttons flash 100 % off. Free buttons are off. Set the LEDs by pressing the respective button 100 % off 1x 50-100 % 2x On - Off 3x Off - 50 % 4x Off - 100 % etc. Setting unassigned buttons as orientation light. LED is off. Press button for approx. 1 second and release it. LED lights up 100 %. Press button for approx. 1 second once again and release it. LED is off. All LEDs have been set. Back to selection level: press and hold button 16 approx. 3 seconds. End selection level: press and hold button 16 Button 5: Tone on/off Switch acknowledgement tone on/off with a touch. Buttons 1-6 light up. Press button 5 (Tone on/off). The mode Tone on/off is active. LED 1 lights up: tone on LED 2 lights up: tone off Back to programming level: press and hold button 16 approx. 3 seconds. End programming level: press and hold button 16. When the tone is switched off, the long acknowledgement tone when the level is changed is eliminated. Button 6: Stations Before light scenes are set, which station is connected with which device address must be entered here. The sensor module recognises whether one or two stations are connected. When one station is connected, only button 1 lights up. 1 2 5 6 Presetting: Relay station to device addresses 1 and 2 Device address 1 Device address 2 Relay station Dimming station Button 1 Button 2 Button 5 Button 6 Fig.8.: Relay station presetting

Buttons 1-6 light up. Press button 6 (stations). The mode Stations is active. To set the stations, press buttons as indicated in the table. Example: Device address 1 dimming station: button 2 Device address 2 relay station: button 5 Back to programming level: press and hold button 16 approx. 3 seconds. End programming level: press and hold button 16. When the tone is switched off, the long acknowledgement tone when the level is changed is eliminated. Reset Reset sensor module to the state as delivered. All settings on the sensor module are overwritten. The sensor module is in normal mode. Press buttons 12 9 7 9 in sequence. All LEDs flash 2x. Press buttons 12 9 7 9 in sequence once again. All LEDs flash 2x, longer acknowledge tone. The state as delivered has been restored. Cloning sensor modules Cloning refers to transmitting the button assignment of a sensor module to other sensor modules. No operation of the relay station is possible during an ongoing cloning operation. Several sensor modules are connected to the relay station. Only sensor modules with the same release status can be cloned. A button has been assigned at one sensor module. Press the MODE and Central Switching Mode buttons of the relay station or the MODE and Prog. button of the dimming station simultaneously until the LEDs, ON/ and OFF/ flash. The stations and sensor modules are in cloning mode. A C flashes at the sensor modules. Press a button on the sensor module being cloned within approx. 2 minutes. A + flashes at the sensor module. All other sensor modules continue to blink a -. Press a button on another sensor module within approx. 2 minutes. If a longer acknowledgement tone is emitted, the cloning was not successful. The procedure must be repeated. LEDs 1-16 switch on in sequence. If all LEDs light up, the transfer is concluded. The sensor module is ready for operation. For further sensor modules, repeat the steps described above. It is not possible to clone devices with different release statuses. Sensor modules with release status R3 register a fault, longer acknowledgement tone; sensor modules with release status R2 can no longer be correctly operated. A reset must be carried out. Cloning mode cannot be ended manually. In order to abort an ongoing cloning mode, do not touch any sensor module for 2 minutes. If cloning mode was activated at the station without any sensor modules being connected, cloning mode is terminated automatically after 3 minutes. Help in case of problems The sensor module does not respond Two stations are connected in parallel Device address of the second station was not converted. Change device address The sensor module does not display the switching state correctly Switch on status feedback to the station (see relay and dimming station instructions). Accessories Universal relay station Art. No.: RS 8 REG HE Universal dimming station Art. No.: UDS 4 REG HE Technical data Rated voltage, button: Max. current DC 24 V SELV approx. 19 ma

Connection Connection terminal Cable length max. 100 m Cable type J-Y(St)4 2x2x0.8 Safety class: III Ambient temperature: -5 C to +45 C Storage/transport temperature: -25 C to +70 C Insert thickness max. 0.25 mm We reserve the right to make technical changes. Warranty Our products are under guarantee within the scope of the statutory provisions. Please send the device, postage paid, to our central Customer Service Centre, with a description of the error. ALBRECHT JUNG GMBH & CO. KG Service Centre Kupferstr. 17-19 44532 Lünen Germany The CE symbol is a free trade symbol, intended solely for the authorities and does not carry any guarantee of properties.