Part 1: How to Avoid Confusion When Testing Insertion Loss According to TIA/EIA-568 B.1 and B.3

Similar documents
The need for Encircled Flux, real or imaginary?

Fiber Optic Testing. The FOA Reference for Fiber Optics Fiber Optic Testing. Rev. 1/31/17 Page 1 of 12

Selection of a cable depends on functions such as The material Singlemode or multimode Step or graded index Wave length of the transmitter

Understanding Multimode Launching Conditions and TIA TSB-178

Fiber Optics Redefined

DESIGN!!GUIDELINES!!!!!

The current state of multimode OTDR and Light Source and Power Meter (LSPM) Insertion Loss (IL) testing is as follows:

We will look first at the cable, and then the transceivers (which act as both transmitter and receiver on each end of the fiber cable).

SSA Fibre-Optic Extender 160 Fibre Installation Guidelines Version 1.2

40G SWDM4 MSA Technical Specifications Optical Specifications

Measuring RL on Short Cables: A Detailed Approach

Pre-bid Supplement #01 Communications Specifications and Additional Scope Project Bid: CM Date: 05/26/2017

Connectix Cabling Systems

SECTION TESTING, IDENTIFICATION AND ADMINISTRATION

40G SWDM4 MSA Technical Specifications Optical Specifications

3M 8900 Single-mode SC Crimplok Connector

Specification of Fusion Splice Loss - FIA TSD Mike Gilmore FIA Technical Director

3M No Polish Jacketed SC/APC Connector

OPERATIONS GUIDE OWL

RFP LC Uniboot to RFP LC Uniboot Patch cord, 2 fibres, Interconnect tight-buffered cable, LSZH

RFP LC Uniboot to RFP LC Uniboot Patch cord, 2 fibres, Interconnect tight-buffered cable, LSZH

ENGINEERING COMMITTEE Interface Practices Subcommittee SCTE STANDARD SCTE

3M No Polish Jacketed SC/APC Connector

MPS Webinar Technical Series

VersiVision. FVTMHA0xA / FVRMHA0xA 16-CHANNEL DIGITALLY ENCODED VIDEO 1-CHANNEL BI-DIRECTIONAL DATA MULTIPLEXER USER S MANUAL.

40GBASE-ER4 optical budget

SECTION COMMUNICATIONS HORIZONTAL CABLING

Field Testing and Troubleshooting of PON LAN Networks per IEC Jim Davis Regional Marketing Engineer Fluke Networks

Module 11 : Link Design

RCIT Cable Certification Testing Revised 10/2017

Delaware County Community College Project # Marple Campus Renovation - Phase % Construction Documents November 23, 2011

100GBASE-SR4 Extinction Ratio Requirement. John Petrilla: Avago Technologies September 2013

Tech Breakfast: Fibre Optic Cabling

Jumpers & Pigtails. Fiber Type OM1, OM3, OM4, 0S1/OS2. Polarity Correction SC and LC duplex clip allows for polarity correction

VersiVision. FVTM2BBxA / FVRM2BBxA 2-CHANNELS DIGITALLY ENCODED VIDEO 2-CHANNELS BI-DIRECTIONAL DATA 2-CHANNELS BI-DIRECTIONAL AUDIO

Mar11 Rev E

Engineering Note. 1 Introduction Basics of Light Propagation in Multi-Mode Fiber... 2

Light Source. Specification & User Manual

Instalaciones de fibra optica en entornos de centro de datos y campus para suportar 40, 100G y mas

VersiVision. FVTM4BCxA-CE / FVRM4BCxA-CE MULTIPLEXER SYSTEM 4-CHANNELS DIGITALLY ENCODED VIDEO 2-CHANNELS BI-DIRECTIONAL DATA

Lensed Fibers & Tapered Ends Description:

UNIVERSITY of NORTH DAKOTA LOW VOLTAGE COMMUNICATIONS STANDARDS FOR CABLING, PATHWAYS, AND SPACE

Panduit Recommended Best Case Practice Split Fibre

MOST - Roadmap Physical Layer & Connectivity from 150Mbps to 5Gbps

ECT5484. Fiber Optic Digital Video, Audio & Data Multiplexer/Demultiplexer. Single Fiber Operation. Specifications

LASERS. Fabry Perot (FP) Distributed Feedback (DFB) Vertical Cavity Surface Emitting Laser (VCSEL)

How to Speak Fiber Geek Article 4: Single-Mode Optical Fiber Geometries

CC-Link IE Controller Network Compatible. CC-Link IE Controller Network Recommended Network Wiring Parts Test Specifications

POLARIZED FIBER OPTIC SOURCE

1. The contractor shall ensure that: c) Contractor or sub-contractor has at least 5 years experience

Keyed LC Connector Solution A LANscape Solutions Product

Cable Certification. General Testing Criteria (Applies to all cable certification testing) Attachment E Cable Certification

Stretch More Out of Your Data Centre s Multimode Cabling System

100G SR4 Link Model Update & TDP. John Petrilla: Avago Technologies January 2013

Category 6A UTP cables shall be tested and proved to conform to TIA-568-C.2 standards.

Introduction to Fiber Optic Cable Technology Jerry Bednarczyk, PE Course Content

100G MMF 20m & 100m Link Model Comparison. John Petrilla: Avago Technologies March 2013

10GBASE-LRM Interoperability & Technical Feasibility Report

MTS/T-BERD Platforms WDMPMD Module

FiberLink 3350 Series

TC Mbps - 622Mbps FIBER OPTIC MODE CONVERTER/REPEATER (Rev A0.1) User's Manual

PM Couplers (Polarization Maintaining Couplers)

o-microgigacn Data Sheet Revision Channel Optical Transceiver Module Part Number: Module: FPD-010R008-0E Patch Cord: FOC-CC****

DEVELOPMENT OF WDM OPTICAL TRANSMISSION SYSTEM OVER GI-POF PAIR CABLE FOR TELEVISION RF, GIGABIT-ETHERNET, AND HDMI/DVI

OPTICAL FIBRE CABLE NETWORK 2004/1

Recommended Changes to Optical PMD Proposal

High Speed Data Connector (HSSDC) For 100 MBit/Sec Token Ring. John L. Hill AMP Incorporated July, 1998

SMF Ad Hoc report. Pete Anslow, Ciena, SMF Ad Hoc Chair. IEEE P802.3bm, Geneva, September 2012

MT-RJ SECURE Product Expansion Now 10 Variants of the MT-RJ SECURE Products

Uniprise Solution Brochure. North America/CALA.

WWDM Transceiver Update and 1310 nm eye-safety

FREEDM Loose Tube Interlocking Armored Cables

For latest revision, visit our website at For Regional Customer Service, visit our website at

100G CWDM Link Model for DM DFB Lasers. John Petrilla: Avago Technologies May 2013

Draft 100G SR4 TxVEC - TDP Update. John Petrilla: Avago Technologies February 2014

SECTION FIBER OPTIC STATION CABLES

FiberLink 7142 Series

RFP LC Uniboot to RFP LC Uniboot Patch cord, 2 fibres, Interconnect tight-buffered cable, LSZH

Assembly code page 46. Cable code page 47. Assembly classes page 48. Polarization maintaining assemblies page 52

MTS/T-BERD 8000 Platform

Telecommunication Infrastructure Project September 20, 2002

T-BERD /MTS-6000, -6000A and Platforms OFI Multifunction Loss Test Module

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

SFCxxB16GExD SFP Dual Fibre CWDM ITU CWDM / 16dB / Gigabit Ethernet

MTS/T-BERD 8000 Platform Optical Spectrum Analyzer Modules

Industry solutions: Broadcast

Cable Jacket - The outermost layer of the fiber cable. Application: Types Single mode Multi mode. Simplex or Duplex available

OCC Installation Conduit Guidelines Excerpt from Optical Cable Corporation s INSTALLATION GUIDE

SFCxxB24GExD SFP Dual Fibre CWDM CWDM / 24dB / Gigabit Ethernet

FiberLink 3500 Series Transceivers

Introduction to Fibre Optics

Optical Component Environmental Test System

The Road to Single Mode: Direction for choosing, installing and testing single mode fiber

Broadband System - D

DATA SHEET. Two (2) fibers Detachable HDMI 2.0 Extender,

Fibre Channel Fiber-to-Fiber Media Converters

SPCxxB10100D SFP+ Dual Fiber CWDM CWDM / 10dB / 10 Gigabit Ethernet

50 Gb/s per lane MMF objectives. IEEE 50G & NGOATH Study Group January 2016, Atlanta, GA Jonathan King, Finisar

Intel Ethernet SFP+ Optics

ADVANCED OPTICAL FIBER SOLUTIONS

Transcription:

Fiber Optic Services And Products EYE ON FIBER Volume 1, Issue 2 August 2002 Part 1: How to Avoid Confusion When Testing Insertion Loss According to TIA/EIA-568 B.1 and B.3 I have been reviewing a Draft 1.0 of TSB 140, Additional Guidelines for Field-Testing Length, Loss and Polarity of Optical Fiber Cabling Systems. In order to understand this draft, I have needed to review six testing procedures (FOTPs) for both multimode and singlemode cable systems. In part 1 of this issue, I will present the methods which are required. TSB140 references the Building Wiring Standard, ANSI/TIA/EIA-568-B.1. This standard calls out different test procedures for multimode and for singlemode cable systems. These two fiber optic test procedures (FOTPs) reference other test procedures, for the enjoyment, or frustration, of those who enjoy complicated puzzles. Multimode Testing Clause 7.1 of the -568 B.3 requires that multimode insertion loss testing be performed in accordance with Method B of OFSTP-14A, otherwise known as TIA/EIA-526-14A. This same clause requires that the light launch conditions meet the requirements of TIA/EIA-455-50 B (FOTP-50 B). Many, but not all light sources are LEDs which overfill the fiber core and therefore, do not meet the requirements of FOTP-50 B. KEY POINT: You need to know whether your light source is a Category 1 source, as designated in Annex A of TIA/EIA-526-14A. Wait. Do not go out to buy a new light source. Your light source may create the required condition internally. If not, you can achieve the required launch condition with a mode filter to strip out higher order modes. These modes can result in field measured attenuation rates which are higher than those stated by the fiber and cable manufacturers. A mode filter, also called an equilibrium mode simulator (EMS) in TIA/EIA-171, is a round tube of a specific diameter. The diameter is determined by the fiber being tested (Table 1). To use the mode filter to create the proper launch condition, you will wrap the light source reference lead (Figure 1) five times

around the mandrel of the proper diameter. This requirement appears in Clause 11.3.3 of TIA/EIA-568 B.1. Table 1: Mandrel Diameter Vs. Cable Diameter and Fiber Type Cable Type 900 µm Fiber Type 2 mm cable 2.4 mm cable 3.0 mm cable 50 µm 24.1 mm 23 mm 22.6 mm 22 mm 62.5 µm 19.1 mm 18 mm 17.6 mm 17 mm Figure 1: Reference Cable Wrapped Around a Mode Filtering Mandrel (Courtesy; Noyes Fiber Optics) KEY POINT: You will need to wrap the reference lead around a mandrel prior to setting the launch power. The use of a mode filter, or mandrel, is a requirement new to field testing of fiber networks in buildings. It did not appear in TIA/EIA-568 A. TIA/EIA-568 A references Method B of TIA/EIA-526-14 A without the requirement for meeting the launch conditions of FOTP-50 B. This change in launch conditions was deemed necessary because of the use of new type of light sources, the vertical cavity, surface emitting laser or VCSEL, which have launch conditions significantly different from those of LEDs. The power loss through links will be less with VCSEL sources than with LED sources (Table 2).

Table 2: Comparison of LED to VCSEL Insertion Loss Test Results Length, m LED Loss, db VCSEL loss, db LED- VCSEL, db 25-0.4-0.5 0.1 25-0.4-0.2-0.2 125-1.1-1.2 0.1 210-3.6-2.0-1.6 22-3.1-1.8-1.3 210-3.4-2.0-1.4 545-5.9-4.6-1.3 average= -0.8 There is good new and bad news about this change. The good news is that this change in launch conditions results in standardized testing conditions regardless of the type of light source in the testing equipment. Now for the bad news: the test results with a mandrel may not simulate the power loss which the transmitter experiences. If the transmitter is a LED which overfills the fiber core, use of the mandrel can result in a power loss which is less than that experienced by the transmitter. If the transmitter is a VCSEL, the use of mandrel wrap can result in a power loss which is greater than that experienced by the transmitter. KEY POINT: troubleshooting of power problems becomes more complicated. The power loss can measure acceptably low and the receiver may receive insufficient power. Conversely, power loss can measure unacceptably high and the receiver may receive sufficient power. This complication arises because the generic test method may not simulate operation. The solution to troubleshooting such power problems is the use of a light source which simulates the operation of the source in the transmitter. That is, if the transmitter has an overfilling LED, the test source should have an overfilling LED. If the transmitter has a VCSEL, in which launched most of the light is launched into the fiber in a donut shaped area with a diameter of approximately 35 µm, the test source should have a VCSEL with the same characteristics.

In order to simulate operation, a testing source must have the same characteristics as the transmitter. These characteristics include: wavelength, spectral width, angle of divergence and spot size and shape. While Singlemode Testing Clause 7.2 of the TIA/EIA-568 B.3 requires that singlemode insertion loss testing be performed in accordance with Method A.1 of OFSTP-7, otherwise known as TIA/EIA-526-7. This method requires that the reference operates as singlemode. To accomplish this requirement, the source reference cable needs a 2 inch diameter loop to filter out the higher order modes which may be present in a short launch cable. Often field installers overlook this loop. Part 2: Evaluation of the Panduit Prepolished SC Connector I have been unimpressed with connectors which do not require polishing. Prior to this project, all of the cleave and leave connectors I have tested and with which I have trained exhibited three problems: excessive power loss, low installation yield and high variability. Our experience did not leave us hopeful. Recently, we tested the Panduit Prepolished SC connectors. Our evaluation method was unorthodox and did not follow all the directions recommended by Panduit. In spite of our method, we found the Panduit SC prepolished connectors to have: the lowest average power loss; the highest installation yield and the lowest variability we have observed from different products using this method of installation. We present the Method A insertion loss test results in Table 3. These results represent the lowest loss, highest yield (19 good out of 20 connector plugs) and most consistent losses we have seen with any of the cleave and leave products. Table 3: 850 nm, Method A Insertion Loss Test Data of Jumpers with the Panduit SC Prepolished Connectors on Both Ends -0.62-0.66-0.77-0.38-0.81-0.36-0.83-0.54-0.42-0.45-0.64-0.47-0.26-0.62-0.81-0.75-0.78 Average= -0.60 Those of you familiar with test results may view as high these values. However, a pair of cleave and leave connectors has two mechanical splices in addition to the connector pair. The Building Wiring Standard, TIA/EIA-568 B allows a maximum splice loss of 0.3 db. If we assume worst case mechanical splices in the connectors, the maximum loss could be as high as 1.35 db/ pair (=0. 75 db/air for the connectors plus 2* 0.3 db for the splices). The results in Table 3 reveal an average of less than half that maximum value.

If we assume that each splice in the backshell has an average loss of 0.15 db, then the average connector loss should be 0.6 db/pair (=0.3 db/ connector pair plus 2* 0.15 db per splice). Against both of these well accepted metrics, the Panduit product compares well. The full installation and test details are in PanduitSCTestResults.pdf. To obtain your copy, request it via email. Part 3: The Proof Is In: Test Data Prove the Value of a Precision Cleaver Since about 1992, Pearson Technologies Inc. has based splicing training on Alcoa Fujikura (AFL) cleavers. We have experienced reduced splice losses and increased yields (good splices/total splices). Recently, we purchased Fujikura fusion splicers with the capability to measure cleave angle. With this equipment, we are able to cleave fibers with different cleavers to determine the differences in performance. We have done so with seven different cleavers, four relatively expensive cleavers from Alcoa Fujikura (AFL) and 3 less expensive cleavers. We present the results in Table 4. The cleave angles are in absolute degrees. These results demonstrate the superior performance of the AFL CT-07 cleavers. This superior performance is indicated by the reduced average cleave angles and reduced standard deviations. We did not directly measure yields, but all of the cleaves made with the AFL cleavers were good. Not all of the cleaves made with the inexpensive cleavers were good. Table 4: Comparison of Absolute Cleave Angles of AFL and Inexpensive Cleavers Cleaver S/N Ave., Standard Deviation, No. Cleaves Notes AFL CT 07 3069 0.36 0.65 22 AFL CT 07 3068 0.22 0.26 20 AFL CT 07 48127 0.21 0.23 12 Bought used AFL CT 07 34670 0.52 0.45 10 Bought used Inexpensive 1 1.31 1.14 22 Good condition Inexpensive 2 1.82 1.39 20 Adequate condition Inexpensive 3 0.79 0.66 18 With new blade

If we were to calculate the total cost of time spent making unacceptable splices or installing high loss cleave and leave connectors, we would find that the more expensive cleaver will pay for itself in reduced labor cost and increased yields. The full test details are in CleaverStudy1.pdf. To obtain your copy, request it via email. Part 4: A Pearson Personal Perspective: Will Fiber Miss the Data Networks Boat? The premises situation does not look good. It has been obvious that many organizations are ignoring the benefits of fiber to the desk (FTTD). The slow but steady progress of UTP categories from 3 to 6 and beyond is witness to that fact. While there has been increasing implementation of FTTD, the rate has been slow. The basic benefits of fiber-increased bandwidth, security, increased transmission distance, low BERs- have not offset the perception of a cost penalty. Even the cost model created by the FOLAN subcommittee of the TIA and Pearson Technologies Inc. (http://www.fols.org/pubs/costmodel.htmlg) does not appear to have changed many minds. Out of this situation comes a concern: what is the future of the premises fiber optic market? This concern leads to examination of competing technologies, specifically, wireless networks. Will end users opt for wireless instead of fiber? If so, then wireless networks becomes an upsetting technology. The wireless arguments of increased ease of installation and increased convenience of use seem to be accepted. In the summer 2002 issue of its alumni magazine, CWRU Magazine, Case Western Reserve University (CWRU) touts its wireless network as being a technology that can more fully exploit the potential of the existing fiber optic infrastructure. In other words, the applications that were thought to justify the need for FTTD have not evolved, even 12 years after the installation. For CWRU, fiber to the desk is no longer necessary or desirable for most computers. Ironically, the CWRU wireless network is only possible because of its advanced fiber network, which was installed in the late 1980s. In the words of the author:..the Internet industry settled on a communication standard that does not exploit the full potential of the fiber optic cable, with the result that, even now, ten years later (after installation of the network) the University investment in the fastest cable available has yet to fully pay off. That is about to change. In the case of CWRU, the FTTD network installed many years ago is about to become a backbone network, with wireless networks feeding it. If the CWRU example represents an example of a trend, the business models of many fiber companies will have to change. Significantly.