ACT 10 Digital Keypad Operating & Installation Instructions This manual is found at

Similar documents
Access Control Keypad for MK-DV, JB-DV

1 EX5. Technical Characteristics. Dimensions

Art M Digital codelock module

Model IQ4-PC User Manual Revision Date:

FlexiScan. Impro FlexiScan 4-Channel Controller INSTALLATION MANUAL

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

ImproX SupaGate 4-Channel Controller INSTALLATION MANUAL

USER S GUIDE. 1 Description PROGRAMMABLE 3-RELAY LOGIC MODULE

RD RACK MOUNT DIMMER OWNERS MANUAL VERSION /09/2011

Provides an activation of Relay 1 triggered by Input 1. The function also provides an option for reverse-logic on the activation of Input 1.

Art. VR4KCLM-1 - VRCLM Digital codelock

Art Stand-alone proximity reader

HS-509 VIBRATION TRIP MODULE

USER & ENGINEER INSTRUCTION MANUAL

Intelligent Security and Fire Ltd

2 CHANNEL RECEIVER DISPLAY POTENTIOMETER COM2 NC2 NO2

ImproX (TRT) Twin Remote Terminal INSTALLATION MANUAL

Ambiflex MF620 USER GUIDE

Tech Support: Customer Service: General Tech Questions: Tech Docs:

Art M Digital codelock module

SR - 516D DESK TOP DMX REMOTE STATION. Version: Date: 05/16/2013

SINGLE ZONE CLIMATE ZONING SYSTEM. Technical Manual. Polyaire Pty Ltd

MODEL 2018 OPERATION MANUAL Firmware Version

Standard RS232 RS ma

XTM72E & F Real-Time Clock Modules

M150SP USER S AND INSTALLER S MANUAL. v2.0 REV. 03/2017

REGO Start&Go USER MANUAL

OWNERS MANUAL. Revision /01/ Lightronics Inc. 509 Central Drive Virginia Beach, VA Tel

multi-function meters

EN Wireless programmable thermostat

ComfortChoice Touch Thermostat. Designed for ZigBee R Wireless Technology USER GUIDE

7 Day Digital Programmer

Mains Supply. 2-wire mains-rated, 0.5 mm² to 1.5 mm² Max. length 300 m (with 1.5 mm² cable). Example: Belden 8471.

INSTALLATION & USER GUIDE

Documentation on all Paxton products can be found on our web site -

Timer Modules. MEU11 24 Hour Module, MEU17 7 Day Module (Without Housing)

ULTRA-VANSTAT WIRELESS PROGRAMMABLE THERMOSTAT FOR CARAVANS

INDEP. QUARTZ MIN. - 1/2 MIN. AFNOR / IRIG B DHF / RADIO

Location. Electrical. Loads. 2-wire mains-rated, 0.5 mm² to 1.5 mm² Max. length: 300 m (with 1.5 mm² cable). Example: Belden 8471.

The 6700 series Panel lock and destination protect

Radio Thermostat Clock

AES-402 Automatic Digital Audio Switcher/DA/Digital to Analog Converter

ED3. Digital Encoder Display Page 1 of 13. Description. Mechanical Drawing. Features

CLOCKAUDIO. MR88 Automatic Microphone Mixer. Version 4.2

SERIES 400 SERIES 620

UHF REMOTE RECEIVER INSTALLATION & PROGRAMMING

ivw-fd122 Video Wall Controller MODEL: ivw-fd122 Video Wall Controller Supports 2 x 2 Video Wall Array User Manual Page i Rev. 1.

INSTALLATION GUIDE 2.4 Inch TFT Terminal Time Attendance & Access Control

SceneStyle2 User Guide

OWNERS MANUAL. Revision /29/ Lightronics Inc. 509 Central Drive Virginia Beach, VA Tel

SPX-5600 Series. Operations Manual. Suprex Reader Extender - RF Wireless Interface SPX-5600MAN. Page 1 of 20

TU-8A. 8 Channel Digital Timer Unit. Programming Guide

RERUN ARCHITECTURAL DMX512 RECORDER OWNERS MANUAL

DATA SHEET Panorama Rudder Indicator, TRI-2

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

263 Series LED Bargraph Indicator and Controllers

CC2000 SERIES SYSTEM CLOCKS / DISPLAYS

AUTOMATIC VIDEO LOSS A/B SWITCH

Video Server SED-2100R/S. Quick Installation Guide

Telemetry Receiver Installation Guide

Sentinel I24 Digital Input and Output Configuration

BBV REAL TIME HQ DISPLAY QUAD MANUAL

Installation Guide. HDMI 4x1 Switcher

Two (2) Channel 365 Day 24 Hr. Timer/Controllers

REMOTE DISPLAY WIRELESS DECODER MK II

VLC-3 USER'S MANUAL. Light Program Controller. M rev. 04 K rev. 00 & ( ( 5, 352*5$0 1 : $ 2 ' 6(77,1*6 )81&7,216

Operating Manual RISH OPTIMA VAF

PLL2210MW LED Monitor

Model 1476-C SuperQuad HR

System pro M DT1-IK DT1-IK/24V DT1-IK/DCF DT2-IK 2CSM204275R0611 2CSM441017D5601 2CSM204285R0611 2CSM204295R0611 2CSM204325R0611

PRELIMINARY. Orbis CU. Preliminary Data Sheet!

TDEPD. Field-Programmable Pressure Switch/Transducer with Integrated LED Display. Programming Sequence Manual

FWD8000 Dante enabled four wire box

VGA AUDIO SWITCHER S MANUAL

E3/DS3 Fibre Extender

Troubleshooting. 1. Symptom: Status indicator (Red LED) on SSR is constant on. 2. Symptom: Output indicator (Yellow LED) on SSR is flashing.

EVF 300 series. Controllers for electric bread and pizza ovens, with touch-keys, in split version and which can be integrated into the unit.

Figure 1: Standard 906 Sensor and Pulser Disc. Figure 2: Standard 906 Sensor and Pulser Wrap

Installation & User Manual For. Styluscom. Wired Video Intercom System. Models StylusAB, StylusABK, StylusAS Manual Version 1.

SERIES x5. Nickel-plated brass Connection 1) PUR cable type 1 Degree of protection. IP 67 Mounting. Embeddable Max. switching frequency

Overview: Specifications: Installation Instructions:

C Module Description

VHF & UHF REMOTE RECEIVERS INSTALLATION AND PROGRAMMING INSTRUCTIONS MODEL NUMBERS TMP-5414 & TMP 5428

.Power Distribution Center. PD-1. Instruction Manual

SBL /SBLG Series Wireless Clock

TeamWork Kits Installation Guide

Light Curtain Type LA

ARS x4 MATRIX SWITCHER Instruction Manual

ivw-fd133 Video Wall Controller MODEL: ivw-fd133 Video Wall Controller Supports 3 x 3 and 2 x 2 Video Wall Array User Manual Page i Rev. 1.

TORK DGU100/DGUM100 7 DAY DIGITAL TIME SWITCH INSTALLATION AND OPERATING INSTRUCTIONS READ INSTRUCTIONS CAREFULLY BEFORE SETTING UNIT

GAUGEMASTER PRODIGY EXPRESS

CR-R880-BL: Indoor/Outdoor Proximity Reader with 10cm (4in) read range

CG-1 CAMERA-GUARD INSTRUCTION BOOK IB647501

XTM72 Exerciser Timer Module

Site Installation Model MP-8433

Single Axis Position Controller

Site Installation Model MP-8424

Telemetry Receiver Installation Guide

SCS318. User Instructions. SCS318 comprising of SCS317 7 Day Wireless Programmable Room Thermostat and SSR303 Receiver

Transcription:

ACT 10 Digital Keypad Operating & Installation Instructions 18-00001 This manual is found at www.eaglesecuritysolutions.co.uk

Installation Notes Always remember to factory default the controller before you start programming. Always remember to place the supplied Varistor across the terminals of the lock terminals to protect the relay contacts. Never use the onboard relay to switch AC mains voltage. An external relay isolated electrically from the ACT 10 should be used for this purpose. Don t forget to change the programming code to something known only to yourself. Important: As with any Access Control system, always ensure there is an alternate means of escape in the event of the unit failing to operate due to power loss or in the event of fire. Product Specification Number of Users Supply Voltage Current Consumption Operating Temperature Door Open Time Relay Contact Rating Controller Size (H x W x D): Controller Weight Installation Mounting Output Rating 10 PIN Codes 12 24 Volts AC or DC 40mA (nominal), 120mA (maximum) -10 to +50 degrees C 0-255 seconds 5A / 250Vac 138 x 87 x 37 (mm) 700 grams Indoor or Outdoor (IP54) Surface or Flush 100mA Ordering Information ACT 10 Digital Keypad ACT 10 ACT 10 Flush Kit ACT 10 FK ACT 10 Weather Shield ACT 10 WS 2

30 Second Programming Guide (For typical Standalone System) 1. Enter Programming Mode On the digital keypad press button. Input the programming code (default is 9999). The LED will flash yellow / orange. 2. Change User 1 Code On the digital keypad press button 0, then press 1. Input the new User 1 code (4 digits) 3. Change Programming code On the digital keypad press button 0. Press. Input the new programming code (4 digits) 4. Exit Programming Mode On the digital keypad press button. The LED turns red and programming mode has been exited. The ACT 10 Digital Keypad is now ready for normal use. Note: The ACT 10 Digital Keypad may be returned to its factory default condition at any time by entering the programming mode and pressing the button three times. 1. Enter Programming Mode For Door 2 Operation 2. Change User 2 Code On the digital keypad: Press Button 0, then Press Button 2 (for User 2). Input the new User 2 code (4 digits) 3. Assign User 2 to Door 2 On the digital keypad: Press Button 1, then Press Button 2 (for User 2), then Press Button 2 (for Door 2). 4. Exit Programming Mode User 2 code will now activate Door 2 Relay. ACT 10 Digital Keypad Programming Press the button followed by the programming code (initially 9999). The yellow LED will flash while in programming mode. To exit the programming mode press button. Exit from programming mode occurs automatically if no key is activated for 30 seconds. 3

Changing Codes: Enter Programming Mode, then Press Step Keypad Entry Operation Example: Assign code 7529 to user 7 1 0 Change Codes 9999 Enter programming 2 0-9, User Number 0-9, = programming code 0 Change Codes 3 0000(00)-9999(99) 4 digit code 0000 deletes User code 7 User 7 7529 PIN code Exit programming Default User Codes: Programming Code: 9999(99); User 1 Code: 1234(56). All others are inactive. Setting Switched Output Combinations: Enter Programming Mode, then Press Step Keypad Entry Operation Example: Assign Toggle to User 7 1 1 Set Outputs 9999 Enter programming 2 0-9 User number 0-9, 1 Set Outputs 3 0-7 Output function code 7 User 7 0 Door Toggle Exit programming Output Function Code Door Output Door 2/Output 2 Output 3 0 Toggled 1 Timed 2 Timed 3 Timed Timed 4 Timed 5 Timed Timed 6 Timed Timed 7 Timed Timed Timed Default function code is 1 (Relay Timed) for all users. When the door is toggled open, this will be indicated by the green indicator flashing. Setting Timers: Enter Programming Mode, then Press Step Keypad Entry Operation 1 2 Set Timers 2 0-4 (Timer number) Buzzer sounds indicating timing. wait required period. 3 (Stop timing) Buzzer stops timer set. Timer Number Function Default 0 Relay time 5s 1 Door 2 / Output 2 time 5s 2 Output 3 time 5s 3 Door Ajar time 30s 4 Guest Buzzer time 2s Timers may be set to any duration between 2 seconds and 4 minutes. 4 This manual is found at www.eaglesecuritysolutions.co.uk

Setting Configuration: Enter Programming Mode, then Press Step Keypad Entry Operation 1 30-37 or 40-47 option number 2 0 or 1 1= Set, 0 = Unset Option Function Default Operation 30 Door Chime Off When set, whenever the door contact is opened, the built-in buzzer makes a chime sound and the buzzer output activates for 2 seconds. 31 Silent Operation Off When set, the keypad operates silently. No audible tones (key-presses or confirm tones) are produced from the built-in buzzer function. 32 Permanent On When set (default), the keypad illumination is always on. This option will Backlighting override option 42 (Auto backlighting) 33 Locksaver Off When set, and when the relay is active (following a valid code or button release), (Anti Tailgating) the relay timer is truncated to 2 seconds when the door contact opens. This ensures that irrespective of programmed relay time, the door will be locked as soon as it closes, and any person following will have to enter a code. 34 Alarm Off When set, the keypad may be used as a remote keypad for an alarm system. The red Keypad and green indicators are controlled by the door contact and the release button inputs Operation inputs respectively, and the built in buzzer is controlled by the interlock input. 35 Interlock Off When set, two or more keypads may be interlocked so that only one controlled door may be open at any one time. The interlock output is active whenever the relay is active or when the door contact is open. When the interlock input is active, the release button and all codes are inactive, the red indicator flashes. The interlock outputs and inputs of any number of keypads may be combined on a single wire. 36 Six Digit Codes Off When set, all user codes, and the programming code, are six digits long. The default user one code becomes 123456 and the default programmer code becomes 999999. 37 Twin Codes Off When set, two different codes must be entered within 15 seconds in order to open the door. The outputs activated are those which have been programmed for the first code to be entered. 40 Door Forced Off When set, the buzzer output is activated, if the door contact opens when a valid Alarm code has not been entered. The output is deactivated when a valid code is next entered. This is useful for monitoring fire doors etc. 41 Group Disable Off When set, the top five user codes (5-9) are inactive any time the interlock input is activated. This restricts access to certain codes under external control (i.e. an alarm system output or a time clock). 42 Auto Off When set, the keypad illumination is normally off, but will switch on in backlighting response to any key being pressed or while in programming mode. This option is overridden by option 32 (permanent backlighting). To prevent any illumination, unset options 32 and 42. 43 Door Ajar Off When set, and the door contact has been open for longer than the time programmed Alarm into the door ajar timer, the built in and external buzzers sound intermittently. The buzzers may be silenced by closing the door and entering a valid code. 44 Guest Button On When set (default) and when the button on the keypad is pressed, the buzzer output is activated for the duration programmed into the guest buzzer timer. 45 Fire Alarm Off When set, the relay is held active whenever the interlock input is active, and Override the green indicator will flash. This is useful for allowing a fire alarm system to override controlled doors. 46 Release Button Off When set, the interlock input activates the door 2 relay which follows output 2 s timer for Second door. This allows two doors to be controlled using one keypad. 47 Duress Off When set, and when a duress code is entered, the door is opened normally and output 2 is activated. A duress code is any valid user code with one added to the last digit. The output will be reset when a valid user code is entered. When the duress option is set, user codes which have 9 as the last digit should be avoided as there is no corresponding duress code. 5

Incorrect Code Lockout When three invalid codes have been entered in a row, the keypad will enter lockout mode for 20 seconds. During this time, the red LED indicator will flash and all PIN codes will be inactive. Restoring Factory Defaults Enter Programming Mode followed by. This restores the ACT 10 Digtal Keypad to its default settings. If the Programming Code has been forgotten, it may be set to 9999 by: 1. Remove the power from the unit. 4. Replace link LK1. 2. Remove link LK1 at the back of the unit. 5. Proceed with programming. 3. Apply power to unit. Note: The keypad will not operate correctly without LK1 in place. Figure 1: Typical ACT 10 Configuration Power up without link if Programming Code has been lost Shows connection for normally DE-ENERGISED lock, (e.g. door-strike). +V 0V Power Supply 12-24V ACDC Door Release Button LK1 O M R O N 5 A 2 5 0 VA C 5A 3 0 V DC O M R O N 5 A2 5 0 V A C 5 A3 0 V DC 12-24 AC/DC + - N/C C N/O Door Contact Volt - Free Tamper Contacts 0V Interlock (PB2) Push Button Door Contact TAMPER INPUTS 0123456789 OUTPUTS Batch: 20xx-1 Product:ACT10 Rev3.0 Serial No. 12345 0V Buzzer OP3 Duress OP2 Interlock RELAY DOOR 2 N/O C N/C +V! Important Always Place Varistor Across All Lock Terminals Guest Buzzer Output sink = 100mA max +V 0V Power Supply 12-24V ACDC Door Release Button for Door 2 Break Glass Unit (optional) Door 2 Shows connection for normally Shows connection for normally ENERGISED energised lock, (e.g. magnetic lock). lock (e.g. magnetic lock) The ACT 10 may be used to control 2 doors as illustrated in the diagram above 6

Figure 2: 1: ACT10 10 Digital Keypad Keypad Schematic Schematic 220/240 Volts AC PSU 12/24 Volts AC/DC 3 Outputs (100mA) Tamper 3 Inputs (100mA) EXIT Figure 3: 2: ACT ACT10 10 Digital Keypad_Guide - to Guide outdoor to installation outdoor installation exposed areas in exposed areas DO silcone all screw mounting positions and cable entry. DO NOT apply silicone to the bottom of the keypad as this will block the air vents and trap any water which may enter the keypad If a weather shield is fitted the same applies DO apply silicone to the top and two sides of the keypad, or shield, when used. DO install a weather shield when the keypad is 1. installed on an uneven surface 2. in an exposed area 7

Installation Instructions for ACT 10 Flush Mount Kit Mount back box into wall void or aperture with wood screws provided Ensure that the cable comes through the cable entry in the back box Remove back plate from the ACT 10 and mount on to the removable cradle with the 3 bolts provided again bringing the cable through the rear cable entry in the back plate Carefully remove the pluggable connector blocks on the ACT 10 and make the required connections Replace the wired connectors in their correct positions and install the front housing of the ACT 10 on its back plate. Any excess cable can be shoved back into the void between the cradle and the back box. Secure the ACT 10 to its back plate with the security screw. Fit the cradle into the back box. Fit the front plate to the back box with the 4 security screws provided. User List User User Name PIN Door 1 Door 2 0 1 2 3 4 5 6 7 8 9 This manual and user list is available for download from our website, www.accesscontrol.ie Unit C1, South City Business Centre, Tallaght, Dublin 24, Ireland Tel: 353-1-4662570 Fax: 353-1-4520427 UK Locall: 0845 300 5204 Web: http://www.accesscontrol.ie E-mail: tech@accesscontrol.ie Copyright 2007 Access Control Technology Ltd. This manual is found at www.eaglesecuritysolutions.co.uk