WECON LX3V-2PT-BD Module

Similar documents
LX3V-2PT-BD User manual

WECON LX3V-2TC-BD Module

WECON LX3V-2TC2DA BD Board

WECON LX3V-2PT2DA BD Board

LX3V-4AD User manual Website: Technical Support: Skype: Phone: QQ Group: Technical forum:

USER S MANUAL. FX2N-8AD Analog input block

PACSystems* RX3i Thermocouple Input Module, 12 Channels, IC695ALG412-CB

PACSystems* RX3i. Isolated Thermocouple Input Module, 6 Channels, IC695ALG306-EB Isolated Thermocouple Input Module, 12 Channels, IC695ALG312-EB

STBART0200K standard analog input kit STB - 2 I - 15 bits + sign

BL67 electronic module 2 analog inputs for thermoelements BL67-2AI-TC

FX-4AD-TC SPECIAL FUNCTION BLOCK USER'S GUIDE

INTRODUCTION TERMINAL LAYOUTS FX2N-4AD-TC SPECIAL FUNCTION BLOCK USER S GUIDE

MicroLogix 1200 Thermocouple/mV Input Module

C200H-AD002/DA002 Analog I/O Units Operation Guide

ANALOG I/O MODULES AD268 / DA264 / TC218 USER S MANUAL

User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W

Power Injector 1520 Series

Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features


CARLO GAVAZZI Automation Components

Weekly Time Switch. Rated time Time setting range Time division 24 hrs x 7 days 00:00 to 23:59 1min

OPERATION MANUAL JENDPM008 THERMOCOUPLE PANEL THERMOMETER. TIP TEMPerature Products 340 W Broad Street Burlington, NJ 08016

USER MANUAL FOR THE ANALOGIC GAUGE FIRMWARE VERSION 1.1

LINK-RAY TM MODULATORS FOR CONSTANT- VOLTAGE. LinkRay Modulators 12 V / 24 V Constant-voltage Applications MODULATORS

R1MS-GH3 BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL THERMOCOUPLE & DC INPUT MODULE MODEL. (8 points; isolated)

MELSEC iq-f FX5 User's Manual (Analog Control - Intelligent function module)

USER MANUAL FOR THE ANALOGIC GAUGE FIRMWARE VERSION 1.0

Digital Temperature & Analog Sensor. Analog Input Port. Digital Port. Front

LED Driver Compact dimming

MODELS USIX-024 AND USIX-120 INSTRUCTION SHEET FOR FEDERAL SIGNAL UNISTAT STATUS INDICATOR MODEL USIX

2 WIRE - LOOP POWERED TRANSMITTER FOR PT100 AND NI100 PROBES

ArmorPOINT RTD and Thermocouple Input Modules

USER MANUAL. PT-201VGA 2x1 VGA Switcher MODEL: P/N: Rev 3

HDMI Cross Converter

User Manual CXE800. Fibre Optic Receiver. CXX Series. Teleste Corporation

E8Y. Micropressure Sensor with Easy-to-Read Digital Display. Differential Pressure Sensor. Ordering Information. Sensors

Preventing Fieldbus Physical Layer Problems

Tutorial on Technical and Performance Benefits of AD719x Family

USER MANUAL. PT-571HDCP DVI Line Transmitter. PT-572HDCP+ DVI Line Receiver MODELS: P/N: Rev 8

Analogue output module DAO 081

Operation Manual for. SCU1 Signal Conditioning Unit

Set Point Controller OC557. Operator s Manual

FX2N-2AD SPECIAL FUNCTION BLOCK

3M Sensored Termination (15 kv) QX-T15I-vi1-E

AES-404 Digital Audio Switcher/DA/Digital to Analog Converter

REMOTE I/O R30 SERIES. PC CONFIGURATOR SOFTWARE Model: R30CFG Ver Users Manual

Thermo-Simple 1 version 2 (TS.1 ver.2) 2013

Process Transmitter RMA 422

Ordering Information. Absolute 60-mm-dia. Rotary Encoder E6F-A. High Accuracy and Durability for Automatic Equipment.

USER MANUAL. PT-571 HDMI Line Transmitter. PT-572+ HDMI Line Receiver MODELS: P/N: Rev 8

USER MANUAL. 640T HDMI Coax Transmitter. 640R Coax HDMI Receiver MODELS: P/N: Rev 1

4K HDMI to 6G SDI Converter with SDI Loop Out P/N User's Manual

User Manual CXE Rev (12) CXX Series. User Manual. Teleste Corporation CXE810. Fibre optic receiver

AS09..S 3-pole Contactors - Spring Terminals

Datasheet - SRB-E-201ST

CR-R880-BL: Indoor/Outdoor Proximity Reader with 10cm (4in) read range

FRQM-2 Frequency Counter & RF Multimeter

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:

CM1-AD08V 0~5V, 1~5V, -10~10V, 0~10V An input signal is converted to a digital value from 0 to or from 8000 to 8000.

USER MANUAL. PSE-4 10G Quad POE Injector MODEL: P/N: Rev 1

SNAP Analog Input Modules. SNAP Analog Input Modules. Features. Description. Part Number

LED control gear Compact fixed output

TeamWork Installation Guide

LED Driver Linear / area fixed output

1 Output 1 operation. 3 Pressure unit display. 4 Main display Large 4-character LCD display. 5 Sub-display Small 4-character LCD display.

LED Driver Compact fixed output

CONTRACTORS SPECIFICATION

Operating instructions

USER MANUAL. PT-102VN 1:2 Video DA MODEL: P/N: Rev 2

Extra long-range RFID (proximity) card reader

USER MANUAL. VM-10xl Video Audio Distribution Amplifier MODEL: P/N: Rev 4

SAFETY PRECAUTIONS. (Read these precautions before using this product.)

FX0N-3A SPECIAL FUNCTION BLOCK

PHASED OUT. LED control gear Compact fixed output. Driver LC 40W 900mA fixc C SNC China Domestic ESSENCE series

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

T775U Series 2000 Electronic Stand-Alone Controller

Displacement Measuring System for Cylinder Series OSP-P

Ultrasonic Sensor Diffuse Mode Sensor RU40U-M18E-LIU2PN8X2T-H1151

LED Driver Compact fixed output

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

LARGE DIGITAL TEMPERATURE LED DISPLAYS

Vorne Industries. 87/719 Analog Input Module User's Manual Industrial Drive Itasca, IL (630) Telefax (630)

AE-341 SERIES PROCESS INDICATORS 2 TO 6 DIGITS 0-20 MA, 4-20 MA, 0-5V, OR 0-10V SCALED INPUT

GPS4000. GPS Time Receiver System. User Manual Version 1.1. World Time Solutions. World Time Solutions Limited

Operating Instructions

2000 Series Weather Stations Analog Temperature / RH Sensor Upgrade Kit PRODUCT MANUAL KIT # 3613WDU

Stability, Speed and Accuracy

T775U Series 2000 Electronic Stand-Alone Controller

48x24. Options ORDER NUMBER OF TYPE PFL B

20 mm Beam Pitch General Purpose Area Sensor. Distance between parts shelf and sensor can be shortened (Enables miniaturization of equipment)

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC

AES-402 Automatic Digital Audio Switcher/DA/Digital to Analog Converter

Kramer Electronics, Ltd.

1. Overview. SSI-1016G interfaces with 24, 25 and 26 bit Temposonics SSI sensor. Block diagram. as PNP open collector output

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell

Dell Wyse 5030 PCoIP Zero Client

Mechanical flow switch for On/Off control

USER MANUAL. VDS Video Display System MODEL: P/N: Rev 2

KRAMER ELECTRONICS LTD. USER MANUAL MODEL: PT-4iREX IR Repeater. P/N: Rev 5

Panel-mounting thermostats, type series EM

Transcription:

WECON Module Website: http://www.we-con.com.cn/en Technical Support: liux@we-con.com.cn Skype: fcwkkj or Jason.chen842 Phone: 86-591-87868869 QQ Group: 465230233 Technical forum: http://wecon.freeforums.net/

1. Mounting instruction Before the installation must be ensure that the PLC host and BD associated equipment power off. Please install the BD module in the corresponding position of the PLC, and lock the four standard screws. If environmental dust is bigger, please cover BD right part by PLC s cover. Please do not power operation. 1) This BD module only support the following firmware versions or later. Users can check the PLC firmware version in D8001. LX3VP:25103; LX3VE: 25201; LX3V-A2:25014; LX3V-A1: 22006; When mounting module to PLC, all the lights are blinking after power ON PLC please upgrade the firmware of PLC. 2) Please fixed BD module on the PLC, poor contact may lead to failure. 3) BD module and top cover of PLC s tightening torque is 0.3 ~ 0.6 N.m. Warring Make sure to power off the PLC before mounting or removing the BD module and put the cover in right place. 2. Special feature 1) It adds two analog inputs (if access two BD modules can be increased 4 analog inputs). The module is mounted on top of PLC, so there is no need to change the PLC installation area. 2) Digital to analog conversion is performed by PT100 in, and the converted digital value is stored in a special registers. However, the characteristics of the analog to digital converter cannot be adjusted. The soft elements corresponding to the different expansion ports are also different. Address assignment in the following table. Table 2-1 address assignment Extension port 1 (far away from PLC LED) Extension port 2 (near PLC LED) Address Description Address Description The flag of RTD type in CH1 The flag of RTD type in CH1 M8112 OFF: RTD Type is PT100 M8116 OFF: RTD Type is PT100 M8113 The flag of RTD type in CH2 M8117 The flag of RTD type in CH2 1 WECON Technology Co., Ltd.

OFF: RTD Type is PT100 OFF: RTD Type is PT100 D8112 CH1 s temperature at 0.1 units D8116 CH1 s temperature at 0.1 units D8113 CH2 s temperature at 0.1 units D8117 CH2 s temperature at 0.1 units 3. Dimension Table 3-1 Sensor type: 2 or 3 wires PT100 L1+ First channel PT100 signal input (+) L1- First channel PT100 signal input (-) L2+ Second channel PT100 signal input (+) L2- Second channel PT100 signal input (-) VI- Common LED lights indicating 1) LED1: ON when power ON. 2) LED2: flashes when communications. 3) LED3 (PT 1): On indicates enable, OFF indicates disable, flicker indicates exceeding the measurement range. 4) LED4 (PT 2): On indicates enable, OFF indicates disable, flicker indicates exceeding the measurement range. If the BD module is plugged into the old firmware version when on the host, all LEDs will be flashing. 4. Specifications 1) Please refer to the LX3V user manual for the general specification of. 2) is powered supply by LX3V main unit. Table 4-1 Item Explanation Analog circuitry DC 24V ±10%, 50mA Digital circuitry DC 5V, 90mA (From the PLC internal power supply) Celsius Read data by buffers Analog input signal PT100 sensor, 3 wires, 4 channels (CH1, CH2, CH3, CH4), 2 WECON Technology Co., Ltd.

3850PPM/ Sensor current 1mA Compensation range -100-600 Digital output -1000-6000 12 bits total, 11 bits for data and 1 bit for sign Accuracy 0.2-0.3 Overall accuracy ±1% Conversion rate 50ms Conversion characteristics 5. Wiring Explanation: 1) 2-wire PT100: when using channel 1, short-circuit L1+ and VI-, connect PT100 s 2 wires to L1+ and L1- respectively. The same setting in channel 2. 2) 3-wire PT100: when using channel 1, two same color wires, connected to the L1- and VI-, the third one connect to L1+. Warning damages. Make sure cut off the electricity before installation/disassembly, to prevent electric shock or product 1) Stay away from high-voltage cables to avoid interference or surge; 2) Grounding is required, but please do not share the ground site with high-voltage cable; 3) Do not weld any cable ends, and make ensure that the number of connecting cables, no more than a predetermined number; 5.1 Suitable cable Use AWG25-16 to connect the output equipment The maximal screwing torque is from 0.5 to 0.6N.m 3 WECON Technology Co., Ltd.

Table 5-1 Line type Cross sectional area(mm 2 ) End-of-pipe treatment AWG26 0.1288 Stranded cable: stripped jacket, rub...... Conductor, then connect the cable. AWG16 1.309 Single-core cable: stripped jacket, Then connect the cable. 5.2 Input Figure 5-1 6. Examples The value of each channel s PT100 is storage in the registers (D8112, D8113) in the form of digital. For output, in each "END" instruction, M8114 and M8115 convert the digital value into an analog output. 6.1 Basic Program Examples 1) M8112 and M8113 are used to analog to digital conversion for CH1 and CH2; 2) only supports PT100; 3) When M8112-M8115 is ON, the channels will not work, all show 0 ; 4) Don t try to change the value in D8112 or D8113, when finished the A/D conversion; 5) Set CH1 and CH2 as thermocouple input mode, and stored value in D0 and D2; The following project sets CH1 and CH2 as PT100 input, and the value is storage in D0 and D2. 4 WECON Technology Co., Ltd.

Set CH1 as K-type thermocouple input mode Set CH1 as K-type thermocouple input mode Set the digital value of D0 into analog value Set the digital value of D2 into analog value 6.2. Examples of Applications Since the does not have offset and gain functions, if it needs for the values out of the standard specifications, Additional programming orders will be needed to multiply or divide the converted value. Since the use of additional programming orders, the converted precision and resolution of the analog value are different with the specifications. The original range of the analog output does not change. Thermocouple input mode In RTD input mode, 2PT covert a analog value to a digital value in degrees Celsius. If in the program was a degree Fahrenheit as a unit it needs to be converted to Celsius value. Fahrenheit and Celsius conversion formula, Fahrenheit = Celsius * 9/5 + 32, the unit is 0.1 D10=D8112*9 D12=D10/5 D0=D12+320 D0=D8112*9/5+320 5 WECON Technology Co., Ltd.