LX3V-2PT-BD User manual

Similar documents
WECON LX3V-2PT-BD Module

WECON LX3V-2TC-BD Module

WECON LX3V-2TC2DA BD Board

WECON LX3V-2PT2DA BD Board

LX3V-4AD User manual Website: Technical Support: Skype: Phone: QQ Group: Technical forum:

USER S MANUAL. FX2N-8AD Analog input block

FX-4AD-TC SPECIAL FUNCTION BLOCK USER'S GUIDE

PACSystems* RX3i Thermocouple Input Module, 12 Channels, IC695ALG412-CB

BL67 electronic module 2 analog inputs for thermoelements BL67-2AI-TC

STBART0200K standard analog input kit STB - 2 I - 15 bits + sign

PACSystems* RX3i. Isolated Thermocouple Input Module, 6 Channels, IC695ALG306-EB Isolated Thermocouple Input Module, 12 Channels, IC695ALG312-EB

INTRODUCTION TERMINAL LAYOUTS FX2N-4AD-TC SPECIAL FUNCTION BLOCK USER S GUIDE

C200H-AD002/DA002 Analog I/O Units Operation Guide

ANALOG I/O MODULES AD268 / DA264 / TC218 USER S MANUAL

MicroLogix 1200 Thermocouple/mV Input Module

Power Injector 1520 Series

User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W

Weekly Time Switch. Rated time Time setting range Time division 24 hrs x 7 days 00:00 to 23:59 1min

LINK-RAY TM MODULATORS FOR CONSTANT- VOLTAGE. LinkRay Modulators 12 V / 24 V Constant-voltage Applications MODULATORS

R1MS-GH3 BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL THERMOCOUPLE & DC INPUT MODULE MODEL. (8 points; isolated)

HDMI Cross Converter

Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features

MODELS USIX-024 AND USIX-120 INSTRUCTION SHEET FOR FEDERAL SIGNAL UNISTAT STATUS INDICATOR MODEL USIX

MELSEC iq-f FX5 User's Manual (Analog Control - Intelligent function module)

CARLO GAVAZZI Automation Components

OPERATION MANUAL JENDPM008 THERMOCOUPLE PANEL THERMOMETER. TIP TEMPerature Products 340 W Broad Street Burlington, NJ 08016

USER MANUAL FOR THE ANALOGIC GAUGE FIRMWARE VERSION 1.1


Operation Manual for. SCU1 Signal Conditioning Unit

Digital Temperature & Analog Sensor. Analog Input Port. Digital Port. Front

USER MANUAL FOR THE ANALOGIC GAUGE FIRMWARE VERSION 1.0

LED Driver Compact dimming

FX2N-2AD SPECIAL FUNCTION BLOCK

2 WIRE - LOOP POWERED TRANSMITTER FOR PT100 AND NI100 PROBES

REMOTE I/O R30 SERIES. PC CONFIGURATOR SOFTWARE Model: R30CFG Ver Users Manual

User Manual CXE800. Fibre Optic Receiver. CXX Series. Teleste Corporation

ArmorPOINT RTD and Thermocouple Input Modules

E8Y. Micropressure Sensor with Easy-to-Read Digital Display. Differential Pressure Sensor. Ordering Information. Sensors

Preventing Fieldbus Physical Layer Problems

USER MANUAL. PT-571HDCP DVI Line Transmitter. PT-572HDCP+ DVI Line Receiver MODELS: P/N: Rev 8

Tutorial on Technical and Performance Benefits of AD719x Family

1. Overview. SSI-1016G interfaces with 24, 25 and 26 bit Temposonics SSI sensor. Block diagram. as PNP open collector output

Analogue output module DAO 081

CONTRACTORS SPECIFICATION

3M Sensored Termination (15 kv) QX-T15I-vi1-E

AES-404 Digital Audio Switcher/DA/Digital to Analog Converter

Thermo-Simple 1 version 2 (TS.1 ver.2) 2013

Operating Instructions

Set Point Controller OC557. Operator s Manual

SNAP Analog Input Modules. SNAP Analog Input Modules. Features. Description. Part Number

SAFETY PRECAUTIONS. (Read these precautions before using this product.)

T775U Series 2000 Electronic Stand-Alone Controller

Process Transmitter RMA 422

Ordering Information. Absolute 60-mm-dia. Rotary Encoder E6F-A. High Accuracy and Durability for Automatic Equipment.

Dell Wyse 5030 PCoIP Zero Client

USER MANUAL. PT-571 HDMI Line Transmitter. PT-572+ HDMI Line Receiver MODELS: P/N: Rev 8

OWNER'S MANUAL KIT INCLUDES. 3M VHB Mounting Pad Mounting Hardware PART # 40040

USER MANUAL. 640T HDMI Coax Transmitter. 640R Coax HDMI Receiver MODELS: P/N: Rev 1

User Manual CXE Rev (12) CXX Series. User Manual. Teleste Corporation CXE810. Fibre optic receiver

4K HDMI to 6G SDI Converter with SDI Loop Out P/N User's Manual

T775U Series 2000 Electronic Stand-Alone Controller

AS09..S 3-pole Contactors - Spring Terminals

Datasheet - SRB-E-201ST

CR-R880-BL: Indoor/Outdoor Proximity Reader with 10cm (4in) read range

USER MANUAL. PT-201VGA 2x1 VGA Switcher MODEL: P/N: Rev 3

FRQM-2 Frequency Counter & RF Multimeter

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:

CM1-AD08V 0~5V, 1~5V, -10~10V, 0~10V An input signal is converted to a digital value from 0 to or from 8000 to 8000.

USER MANUAL. PSE-4 10G Quad POE Injector MODEL: P/N: Rev 1

TeamWork Installation Guide

LED control gear Compact fixed output

MICROMASTER Encoder Module

LED Driver Linear / area fixed output

1 Output 1 operation. 3 Pressure unit display. 4 Main display Large 4-character LCD display. 5 Sub-display Small 4-character LCD display.

USER MANUAL. PT-102VN 1:2 Video DA MODEL: P/N: Rev 2

Operating Instructions 07/2007 Edition. SINAMICS G130/G150 Line harmonics filter. sinamics

Operating instructions

LED Driver Compact fixed output

BNC-2110 DESKTOP AND DIN RAIL-MOUNTABLE BNC ADAPTER

Signet 2250 Hydrostatic Level Sensor

USER MANUAL. VM-10xl Video Audio Distribution Amplifier MODEL: P/N: Rev 4

User s Manual Model WF100 Extension Cable for EXA100

Horn loudspeaker, Ex proof, short/long flare

FX0N-3A SPECIAL FUNCTION BLOCK

PHASED OUT. LED control gear Compact fixed output. Driver LC 40W 900mA fixc C SNC China Domestic ESSENCE series

CC-Link IE Field Network Analog-Digital Converter Module User's Manual -NZ2GF2BN-60AD4 -NZ2EX2B-60AD4

DANGER. DANGER indicates a hazardous situation which, if not avoided, will result in death or serious injury. WARNING

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

READ THESE INSTRUCTIONS COMPLETELY AND CAREFULLY

Serial Flash Programmer. S550-SFWv3 FA Mode. Operation Manual. Sunny Giken Inc.

Displacement Measuring System for Cylinder Series OSP-P

Ultrasonic Sensor Diffuse Mode Sensor RU40U-M18E-LIU2PN8X2T-H1151

LED Driver Compact fixed output

VGA to DVI Extender over Fiber SET

INTRODUCTION TERMINAL LAYOUTS FX2N-4AD SPECIAL FUNCTION BLOCK USER S GUIDE

Vorne Industries. 87/719 Analog Input Module User's Manual Industrial Drive Itasca, IL (630) Telefax (630)

GPS4000. GPS Time Receiver System. User Manual Version 1.1. World Time Solutions. World Time Solutions Limited

Kramer Electronics, Ltd.

48x24. Options ORDER NUMBER OF TYPE PFL B

Single Point Flow Monitor SW118 SW119

Transcription:

User manual Website: http://www.we-con.com.cn/en Technical Support: support@we-con.com.cn Skype: fcwkkj Phone: 86-591-87868869 QQ: 1043098682 Technical forum: http://wecon.freeforums.net/

1. Mounting instruction Before the installation must be ensure that the PLC host and BD associated equipment power off. Please install the BD module in the corresponding position of the PLC, and lock the four standard screws. If environmental dust is bigger, please cover BD right part by PLC s cover. Please do not power operation. Caution 1) This BD module only support the following firmware versions or later. Users can check the PLC firmware version in D8001. LX3VP:25103; LX3VE: 25201; LX3V-A2:25014; LX3V-A1: 22006; When mounting module to PLC, all the lights are blinking after power ON PLC please purchase new PLC. 2) Please fixed BD module on the PLC, poor contact may lead to failure. 3) BD module and top cover of PLC s tightening torque is 0.3 ~ 0.6 N.m. Warning Make sure to power off the PLC before mounting or removing the BD module and put the cover in right place. 2. Special feature 1) It adds two analog inputs (if access two BD modules can be increased 4 analog inputs). The module is mounted on top of PLC, so there is no need to change the PLC installation area. 2) Digital to analog conversion is performed by PT100 in, and the converted digital value is stored in a special registers. However, the characteristics of the analog to digital converter cannot be adjusted. The soft elements corresponding to the different expansion ports are also different. Address assignment in the following table. Extension port 1 (far away from PLC LED) Table 2-1 Extension port 2 (near PLC LED) 1 WECON Technology Co., Ltd.

Address Description Address Description The flag of RTD type in CH1 The flag of RTD type in CH1 M8112 OFF: RTD Type is PT100 M8116 OFF: RTD Type is PT100 The flag of RTD type in CH2 The flag of RTD type in CH2 M8113 OFF: RTD Type is PT100 M8117 OFF: RTD Type is PT100 D8112 CH1 s temperature at 0.1 units D8116 CH1 s temperature at 0.1 units D8113 CH2 s temperature at 0.1 units D8117 CH2 s temperature at 0.1 units 3. Dimension Table 3-1 Sensor type: 2 or 3 wires PT100 L1+ First channel PT100 signal input (+) L1- First channel PT100 signal input (-) L2+ Second channel PT100 signal input (+) L2- Second channel PT100 signal input (-) VI- Common LED lights indicating 1) LED1: ON when power ON. 2) LED2: flashes when communications. 3) LED3 (PT 1): On indicates enable, OFF indicates disable, flicker indicates exceeding the measurement range. 4) LED4 (PT 2): On indicates enable, OFF indicates disable, flicker indicates exceeding the measurement range. If the BD module is plugged into the old firmware version when on the host, all LEDs will be flashing. 4. Specifications 2 WECON Technology Co., Ltd.

1) Please refer to the LX3V user manual for the general specification of. 2) is powered supply by LX3V main unit. Table 4-1 Item Explanation Analog circuitry DC 24V ±10%, 50mA Digital circuitry DC 5V, 90mA (From the PLC internal power supply) Celsius Read data by buffers Analog input signal PT100 sensor, 3 wires, 4 channels (CH1, CH2, CH3, CH4), 3850PPM/ Sensor current 1mA Compensation range -100-600 Digital output -1000-6000 12 bits total, 11 bits for data and 1 bit for sign Accuracy 0.2-0.3 Overall accuracy ±1% Conversion rate 700ms Conversion characteristics 5. Wiring Explanation: 1) 2-wire PT100: when using channel 1, short-circuit L1+ and VI-, connect PT100 s 2 wires to L1+ and L1- respectively. The same setting in channel 2. 2) 3-wire PT100: when using channel 1, two same color wires, connected to the L1- and VI-, the third one connect to L1+. Warning: 3 WECON Technology Co., Ltd.

Make sure cut off the electricity before installation/disassembly, to prevent electric shock or product damages. Caution: 1) Stay away from high-voltage cables to avoid interference or surge; 2) Grounding is required, but please do not share the ground site with high-voltage cable; 3) Do not weld any cable ends, and make ensure that the number of connecting cables, no more than a predetermined number; 5.1 Suitable cable Use AWG25-16 to connect the output equipment The maximal screwing torque is from 0.5 to 0.6N.m Table 5-1 Line type Cross sectional area(mm 2 ) End-of-pipe treatment AWG26 0.1288 Stranded cable: stripped jacket, rub...... Conductor, then connect the cable. AWG16 1.309 Single-core cable: stripped jacket, Then connect the cable. 5.2 Input mode Figure 5-1 6. Examples The value of each channel s PT100 is storage in the registers (D8112, D8113) in the form of digital. 4 WECON Technology Co., Ltd.

For output, in each "END" instruction, M8114 and M8115 convert the digital value into an analog output. 6.1 Basic Program Examples Caution 1) M8112 and M8113 are used to analog to digital conversion for CH1 and CH2; 2) only supports PT100; 3) When M8112-M8115 is ON, the channels will not work, all show 0 ; 4) Don t try to change the value in D8112 or D8113, when finished the A/D conversion; The following project sets CH1 and CH2 as PT100 input, and the value is storage in D0 and D2. Set CH1 as PT100 input mode Set CH1 as PT100 input mode Set the digital value of D0 into analog value Set the digital value of D2 into analog value 6.2. Examples of Applications Since the does not have offset and gain functions, if it needs for the values out of the standard specifications, Additional programming orders will be needed to multiply or divide the converted value. Caution Since the use of additional programming orders, the converted precision and resolution of the analog value are different with the specifications. The original range of the analog output does not change. Thermocouple input mode In RTD input mode, 2PT coverts analog value to digital value in degrees Celsius. If in the program was a degree Fahrenheit as a unit it needs to be converted to Celsius value. Fahrenheit and Celsius conversion formula, Fahrenheit = Celsius * 9/5 + 32, the unit is 0.1 5 WECON Technology Co., Ltd.

D10=D8112*9 D12=D10/5 D0=D12+320 D0=D8112*9/5+320 Version: V1.0.1 Date: Feb 2018 6 WECON Technology Co., Ltd.