CP017 USER OPERATING INSTRUCTIONS. Single Channel Timeswitch

Similar documents
CP027. User Operating Instructions. Two Channel Central Heating and Hot Water Programmer

ServicePlus S17R Series 2 User Operating Instructions

ChannelPlus H17XL Series 2 User Operating Instructions

Electronic 7 User Operating Instructions

SCS318. User Instructions. SCS318 comprising of SCS317 7 Day Wireless Programmable Room Thermostat and SSR303 Receiver

1 Channel Multi-Purpose Programmer User Instructions

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

24 Hour & 7 Day Digital Immersion Heater Timeswitch Article

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

Programmable Room Thermostat With RF

Lifestyle. Dual Channel Programmer. for heating AND hot water. Installation and User Instructions DUAL CHANNEL ISSA

7 Day Digital Light Switch with Optional Dusk Start

7 Day Digital Programmer 3 Channel Surface Mount

7 Day Digital Programmer

Waterline Room Controller - Type WLCT3

ST9100C User Guide. Features

Comfort System T-32-P Universal Thermostat. Operation Manual

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

Digital Economy Seven Programmer

24Hour/7Day Electronic Timeswitch

TDDFM14 OWNER S MANUAL

USER & ENGINEER INSTRUCTION MANUAL

Digital Time Switch. Installation & Operating Instructions

7 Day Digital Time Switch

Inserting the batteries. Basic settings of the remote control

RT505TX Programmable. The RT505TX can be used with any of these receivers RXBC605 RXWBC605 RXVBC605 RXST MHz

16 Amp Electronic 24 Hour/7 Day Time Controller

Room thermostat Instructions for Use. For the user. Instructions for Use. geotherm

[I] SELECTING ACTUAL TIME. )lf~ IMPORTANT: INSTALLER, Please leave this guide with the householder together with its Warranty card.

ST625TX Digital Room Thermostat

WiFi Controlled Fused Spur Time Switch

1. General Information:

7 DAY DIGITAL LIGHTSWITCH WITH OPTIONAL DUSK START INSTALLATION & OPERATING. Cat No. ZV700 INSTRUCTIONS

S-Series Digital Thermostat. Instruction Manual Model No ST620RF

EXTERNAL. A digital version of this document is available to download and submit online at ADDRESS POST CODE

Radio Thermostat Clock

A digital version of this document is available to download and submit online at ADDRESS POST CODE

Operating instructions. Universal timer switch display

--o.. tl. D NEXT ON/CfF Ct»V.[] D USER INSTRUCTIONS. + Simple change to 5 day/2 day mode ON. FP75-7 day programmer with separate outputs for

XTM72 Exerciser Timer Module

2 Verify that the green light

INSTRUCTION MANUAL DLC400BP DIGITIAL LIGHTING CONTROLLER FOR TECHNICAL SUPPORT: USA

ULTRA-VANSTAT WIRELESS PROGRAMMABLE THERMOSTAT FOR CARAVANS

LP20. Installation & User Guide. Dual Channel Programmer. Part number 25039DR

Ducasa Digital Programmer

EN Wireless programmable thermostat

Timer Modules. MEU11 24 Hour Module, MEU17 7 Day Module (Without Housing)

DIGITAL TIME SWITCH 7 DAY WITH INPUT DGU100A DGUM100A DGLC100A DGLC200A

Timer Modules. EL11 24 Hour Module EL17 7 Day Module. Installation & Operating Instructions

SCENEMASTER 3F QUICK OPERATION

SET TOP BOX MODEL: GDB01SFV1 USER MANUAL

RD RACK MOUNT DIMMER OWNERS MANUAL VERSION /09/2011

Aspect 2 Circuit Digital Scene Control

Battery Operated Controllers

Installation & Programming Manual. Please read before using this timer.

RAMMER INSTRUCTION MANUAL FITTING & OPERATING INSTRUCTIONS NEL PROGRAMMER. NSTAR Si MODELS

SINCE User Manual 7 DAY PROGRAMMABLE DIGITAL TIMER MODEL PS-100. The best solutions for automation and protection.

Sample BD Tech Concepts LLC

XTM72E & F Real-Time Clock Modules

QUADRANT DVB-T Modulator USER GUIDE. Quadrant DVB A N T E N N A I R. Copyright 2012 Antennair Limited, Neo House, Shaw Road, OLDHAM OL1 4AW. Issue 1.

Operation Guide 6022 ENGLISH

Slimline Digital Electric Radiator. Step by Step Programming Guide

Instruction Manual for Programmable Digital Timer

User Guide. The system is controlled via a 6 touch panel located in the lectern. Splash page. This is the page shown when the system is off.

Classroom Setup... 2 PC... 2 Document Camera... 3 DVD... 4 Auxiliary... 5

Registers type ILR7XX and ILR7XXT

TP7001 Range Electronic 7 Day Programmable Room Thermostat. Danfoss Heating. Installation Guide

INSTALLATION & OPERATING INSTRUCTIONS SINGLE/TWO CHANNEL 24HR/7 DAY TIMER. Cat No. TR671/TR672TOP

Troubleshooting CS800/LC900 Bikes

DTS400B - DZS400BP 3/9/07 10:14 AM Page 1

Arduino Nixie Clock Classic Rev4 and Rev5 All In One Modular Rev2

COMFORT COMFORT CALL OWNER S MANUAL CALL SYSTEM P/N P BASE STATION & RF WIRELESS MODULE. Complete Control from TOTALINE

Sample BD Tech Concepts LLC

TU-8A. 8 Channel Digital Timer Unit. Programming Guide

Arduino Nixie Clock Modular Rev3

The smart valve with 3 Independent programs + 2 extra modes

TORK DGS180 DIGITAL SIGNAL TIMER 24 HOUR WITH DAY OMIT

Important Information

INSTRUCTION MANUAL COMMANDER BDH MIG

Operations. BCU Operator Display BMTW-SVU02C-EN

Instructions Manual

SPIRIT. SPIRIT Attendant. Communications System. User s Guide. Lucent Technologies Bell Labs Innovations

SINGLE ZONE CLIMATE ZONING SYSTEM. Technical Manual. Polyaire Pty Ltd

BLOCK OCCUPANCY DETECTOR

TRANSCENSION 6-CHANNEL DMX DIMMER PACK (order code: BOTE40) USER MANUAL

Transfer Switch. OTECA (Spec A) OTECB (Spec A) OTECC (Spec A) OTECD (Spec A) Amperes. English Original Instructions (Issue 5)

User interface. Abbreviations / Meanings

SceneStyle2 User Guide

THE FROG SERIES OPERATING MANUAL

Installation. Insert the mains plug into a wall socket ( V/50Hz). Insert the aerial plug in to the socket M at the rear of the set.

GDB9 INSTRUCTION MANUAL DIGITAL TERRESTRIAL RECEIVER

Arduino Nixie Clock Modular Rev3

Master Time Clock MTC Users Manual

Tube Rotator. User Guide. Version 1.2

User s Guide. ECx Features: Automatic Sprinkler System Timer

Innovative Air Systems ABN When Calling For Support Quote:.doc

Digital Adapter Easy Setup Guide. Installation Operation Troubleshooting

User s Guide. ECx Features: Automatic Sprinkler System Timer

RD-1 ROBERTS. FM /DAB digital radio with. Sound for Generations. Gemini 1. Please read this manual before use

Dimming actuators GDA-4K KNX GDA-8K KNX

Transcription:

CP017 USER OPERATING INSTRUCTIONS Single Channel Timeswitch The CP017 timeswitch will allow up to 3 ON/ settings per day for each day of the week and has a 1 hour manual boost and advance button to temporarily override current settings. There is also a programming switch allowing permanent selection of: /ON//. 1

The CP017 timeswitch The simple instructions contained in this user guide are designed to help with the programming and operation of the unit. 1 SET indicator - RUN is the normal position 2 Time of day 3 Switch period symbol 4 SET button 5 BOOST or adjust (-) button 6 ADVANCE or adjust (+) button 7 button 8 SELECT or COPY button 9 System ON indicator 10 SET positions 11 PROGRAMME positions 12 BOOST symbol 13 ADVANCE symbol 14 AM/ symbol 15 Day of week indicator 16 PROGRAMME indicator 2

Manual Overrides Boost Function - 1 Hour Temporary Override The boost facility will allow the user to boost the system which is currently for 1 hour. To indicate the boost being activated BOOST will be shown on the display for the duration of the boost period. The system ON indicator will also be illuminated. Press BOOST button once for 1 hour of hot water At any time during a BOOST period press BOOST again to return to normal programming RUN CLOCK PROG BOOST Advance Function Brings fo rward the next on or off operation The advance facility will allow the user to advance the system to ON when currently or switch the system when currently ON. To indicate the advance feature being activated ADVANCE will be shown on the display until the next programme switching time. The system ON indicator will also be illuminated Press ADVANCE button once to move to the next ON/ time To cancel the advance press the ADVANCE button again. this will return the unit to its normal programme RUN CLOCK PROG ADVANCE 3

Override Facilities With the CP017 timeswitch operating in the normal running mode it is possible to alter the functionality of the programme by means of the SELECT button. The options include; Auto - Timeswitch follows all programmed ON and times. All day - Timeswitch operates from 1st ON time until 3rd, ignoring all switching times in between. 24hrs - Timeswitch will be constantly ON. Off - Timeswitch will be constantly, there is the ability to turn off the heating during the summer without altering the programme times. Boost is still available. All of the settings above will be permanent, i.e. unaffected by programme times, until alteration by the user. The diagram below illustrates how to alter the setting, it assumes that the programme is in the mode to begin with. Press SELECT once. goes from to Press SELECT again. goes from to Press SELECT again. goes from to Press SELECT again. goes from to Timeswitch will operate from 1st ON until 3rd period Timeswitch will be continuously ON Timeswitch will be continuously will return to normal ON and times 4

Setting Time of Day and Date The CP017 has a built in clock and calendar. This will mean that you will need to enter the date as well as the time on initial set up or if the factory re-set has been used. Having done this, the clock will automatically adjust for BST/GMT time changes throughout the year. Press the set button until the set indicator is next to the clock position adjust the hour and press adjust the minutes and press set the date and press set the month and press set the year and press Once the year is set and the button is pressed the process is complete and the display will return to the run position Check that the correct time and day are showing in the display. If the wrong day is showing in the display that would indicate that the date has not been set correctly and the above process should be repeated 5

Setting the On and Off Times To alter these settings please proceed as follows:- Press the set button until set indicator is next to HW or CH PROG Position Use buttons to adjust day Press Use buttons to adjust 1st ON time Press Use buttons to adjust 1st time Press Repeat this process for 2nd and 3rd settings Enter the 3rd time and the word COPY is displayed To follow the copy route and repeat all programmed times for another day go to 1 To set independent times for other days go to 2 1 select day required and press COPY IN is displayed to confirm the COPY Repeat for other days as required To transfer to independent times for other days go to 2 or to finish programming press the SET button until the SET indicator is in the RUN position 2 Press. select the day required and press. Set 1st, 2nd and 3rd times as before. To repeat for other days go to 2, to COPY go to 1 To finish programming press the SET button until the SET indicator is in the RUN position Default Time settings st 1 ON st 1 nd 2 ON nd 2 rd 3 ON rd 3 6.30AM 8.30AM 12.00 12.00 4.30 10.30 The default time settings shown above are preset at the factory NB. The factory default settings for the 2nd ON/ times are both set at 12:00pm (midday) which cancels this ON period giving 2 ON/ periods for the day. If a midday ON period is required set the 2nd ON and times accordingly. If not press twice. 6

Resetting the r Electronic equipment can in some circumstances be affected by electrical interference. If the programmer s display becomes frozen or scrambled; or if you wish to revert back to the default time settings please reset by pressing the SET and SELECT gether as shown below. After initial installation it is advisable, before programming the CP017 for the first time, to reset the unit. Resetting can only be achieved with the power ON by pressing the SET and SELECT gether. This will return the programmer to the factory set default times. Press the SET and SELECT buttons together then release the buttons and the programmer will return to preset factory settings SET SELECT 7

General Information BATTERY The programmer is fitted with a non-rechargeable, long life battery, which will maintain the programmed time settings for a minimum of ten months with the supply disconnected. THIS SHOULD BE SUFFICIENT TO COVER POWER INTERRUPTIONS DURING THE LIFE OF THE UNIT. During power interruptions the display will be blank, after 3 days the current time of day will be lost. These measures are to prolong the battery life. SERVICE AND REPAIR This programmer is NOT user serviceable. Please do not dismantle the unit. In the unlikely event of a fault developing please refer to the RESETTING THE PROGRAMMER section of this user guide shown above. If this fails to resolve the problem please contact a local heating engineer or a qualified electrician. www.iqe.co.uk Trade House BA22 8RT Leaflet Number P85481 Issue 1 8