MPO Technology Connectivity & Application

Similar documents
Connectix Cabling Systems

How to Specify MTP Pre-terminated Optical Cabling. January White Paper. Published

TECHN. Purpose. Background. to prepare the. A A Patch cord. horizontal infrastructure

Arista 40G Cabling and Transceivers: Q&A

The Road to Single Mode: Direction for choosing, installing and testing single mode fiber

ULTRA HIGH DENSITY SOLUTION GUIDE

400GBASE-SR16 Cabling

HI-DEX PRODUCT SET DATASHEET

Instalaciones de fibra optica en entornos de centro de datos y campus para suportar 40, 100G y mas

DATA CENTER OPTICAL ASSEMBLIES TO SUPPORT QSFP, CFP AND CXP INDUSTRY STANDARD PINOUT CONFIGURATIONS

Fibre Optic Cable & Connector Guide

MT Connect Pre-Terminated Fibre Cabling Systems

QuickNet Fiber Cabling in the Data Center

Empowering businesses through innovative network solutions.

3M Telecommunications. Solutions for Networks. 3M MPO solutions. High Density Networks. Technology built for business

To select a fibre optic cable, you have to make choices of the fibre selection and the cable construction selection.

40G SWDM4 MSA Technical Specifications Optical Specifications

UHD System ULTRA HIGH-DENSITY RACK-MOUNT FIBER CONNECTIVITY SYSTEM

Stretch More Out of Your Data Centre s Multimode Cabling System

Fiber Optics Redefined

Data Centres. Smart Solutions for 300 M OM4 120 M 120 M 400 M. Cat 8 30 M 85 M. Cat 7A 30 M OM3. Cat 6A 100 M OM4 OM3 85 M OM3 900 M 40G 40G 25G 100G

Panduit HD Flex Fiber Cabling System: Built for Next-Generation Density Demands.

Cable Jacket - The outermost layer of the fiber cable. Application: Types Single mode Multi mode. Simplex or Duplex available

Job Aid Server and CSS Separation Avaya S8700 Media Server

Common Public Radio Interface Fiber :: Telect HDX & ELF CPRI Panels and Modules

40GBd QSFP+ SR4 Transceiver

RCIT Cable Certification Testing Revised 10/2017

40G SWDM4 MSA Technical Specifications Optical Specifications

SYSTIMAX Solutions InstaPATCH 360 Pre-Terminated Fiber Solution Guide

INSTALLATION MANUAL FT-FOTR-1VDE-ST-S

Cable Installation Tips

Cable Installation Tips

100G QSFP28 SR4 Transceiver

IQORXD Dual-Channel Multimode Fibre Optic Receiver for SDI

100G-FR and 100G-LR Technical Specifications

Simple View TM. From the beginning to the end. We leave nothing out when it comes to your satisfaction.

MT-RJ SECURE Product Expansion Now 10 Variants of the MT-RJ SECURE Products

o-microgigacn Data Sheet Revision Channel Optical Transceiver Module Part Number: Module: FPD-010R008-0E Patch Cord: FOC-CC****

User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W

IQOTXD Dual-Channel Multimode Fibre Optic Transmitter for SDI

P-2 Installing the monitor (continued) Carry out as necessary

FirstLight Ultra High Density Pre-Terminated Module Datasheet

Robert Burén. Product Manager. Nexans Cabling Solutions. 10G Solutions

OPTICAL CHARACTERISTICS (applied to 12c MPO/MTP ) Item Parameter Reference

Advanced PoE - The Impact of Higher Power PoE++ on Twisted-Pair Structured Cabling

Keyed LC Connector Solution A LANscape Solutions Product

Opterna. Sliding Fiber Optic Patch Panel. Sliding Fiber Optic Patch Panel. Visit: Opterna.com. Data Center Solutions. Introduction

MAXCOM PRODUCT SPECIFICATIONS FIBER OPTIC VIDEO / AUDIO / ASI LINK. Model MX3257HD. Description. Features. Model Selection Guide

QuickNet Copper Cabling in the Data Center

COE Group plc. Contents

Connectivity accessories by Nestor Cables

FIBER OPTIC CABLE CUT TO YOUR EXACT SPECS TO SAVE YOU TIME AND MONEY

High Speed Data Connector (HSSDC) For 100 MBit/Sec Token Ring. John L. Hill AMP Incorporated July, 1998

Datasheet: MultiFiber Pro

Features: Compliance: Applications: Warranty: 49Y7928-GT QSFP+ 40G BASE-SR Transceiver IBM Compatible

HD Flex Patch Panel. ASSEMBLY VIEW (FLEX1UPN** shown) FS128B. CONTENTS: (#) indicates FLEX4UPN** quantity

MICROSENS. Fast Ethernet Switch Modul 4x 10/100Base-TX, 1x 100Base-FX. Description. Features

Cabling Systems for Data Centers

Smart Choices. for Data Center

IT/AV Designs for Schools. Stronger Networks for Smarter Students. By Kit Gaines, Specification Engineer, Network Solutions

UNIVERSITY of NORTH DAKOTA LOW VOLTAGE COMMUNICATIONS STANDARDS FOR CABLING, PATHWAYS, AND SPACE

PreCONNECT Mobile PRODUCT INFORMATION

Section Communications Optical Fiber Backbone Cabling

Exercise 1-2. Digital Trunk Interface EXERCISE OBJECTIVE

Infinity Fibre Distribution Frame

Fibre Channel Fiber-to-Fiber Media Converters

Structured Cabling. Product Line Brochure

Event Master series link-cable solutions for E2, S3 4K, and EX

Gigabit Multi-mode SX to Single Mode LX Converter. User s Manual NGF-728 Series. Warning COPYRIGHT

400G-FR4 Technical Specification

GATOR PATCH. The ultimate fiber distribution terminal

Option TELCO / RJ-45 The converter is available either with twelve RJ45 jacks or one TELCO connector on the 10Base-T side.

INSTALLATION GUIDE. LANmark-OF Zone Distribution Box

200GBASE-DR4: A Baseline Proposal for the 200G 500m Objective. Brian Welch (Luxtera)

Installation. Step 1 Carefully unpack the package contents.

OPTICAL DISTRIBUTION STATION -

Datasheet: MultiFiber Pro Update

LTX Optical Distribution Panels. Ordering Guide

D131x-apbpmslc TECHNICAL DATA. Fiber Optic Patch Cords Simplex LSZH. Description. Features & Benefits

FOM-1090 FOM-1090 FOM FOM-1090 w/ DB-25 Female FOM-1091 w/ DB-25 Male

Clarity Advanced Solutions6A

Follow The Leader In Shielded Technology

HDMI 2.0 EXTENDER OVER CATX OR FIBER

Product information 19" 1U HD Patch Panel 48xRJ45/s, Cat. 6A, gray, fully populated

The need for Encircled Flux, real or imaginary?

Fiber Optic Testing. The FOA Reference for Fiber Optics Fiber Optic Testing. Rev. 1/31/17 Page 1 of 12

HDMI over Optical Fibre Transmitter & Receiver Kit # 15354

Belden IBDN System 10GX Enabling Technologies

We will look first at the cable, and then the transceivers (which act as both transmitter and receiver on each end of the fiber cable).

10G SFP+ Modules. 10G SFP+ Module Series

Barco service bulletin

INSTALLATION MANUAL FT-FOTR-8VD-ST-S. 8-Channel Digital Duplex Baseband Video Transmitter and Receiver With Reverse Data Transmission for PTZ Cameras

3 DIMENSIONS OF EXCELLENCE PERFORMANCE SCALABILITY EFFICIENCY DATA CENTER LOCAL AREA NETWORK

Advanced Test Equipment Rentals ATEC (2832)

May Solution book Data Center

QSFP+ 40GBASE-SR4 Fiber Transceiver

APPROVED for connection to Telecommunication systems specified in the instructions for use subject to the conditions set out in them.

10Gb/s Copper Physical Infrastructure Next Generation Category 6A Cabling System

Aerospace Fiber Optics

FiberLink 3355 Series

Transcription:

MPO Technology Connectivity & Application White paper White Paper MPO Technology Connectivity & Application v1.0 1

Introduction It has been proved that reducing cable diameters and increasing connection densities offered by fibre links would be extremely valuable during installation in constrained space like data centre, large enterprise equipment rooms, central office, etc. With the market turning to 40/100G transmission, to reduce congestion during cabling and make it easier to organize equipment cable runs, the network designers turn to MPO/MTP technology and components for today's duplex fibre transmission. Then, network designers face another challenge which is how to assure the proper polarity of these array connections using MPO/MTP components from end-to-end. Traditionally, a fibre optic link requires two fibres for full duplex communications. It is very important to ensure that the equipment on the link are connected properly at each end. However, when the link contains two or more fibres, maintain the correct polarity across a fibre network become more complex, especially when using multi-fibre MPO components for high data rate transmission. Luckily, pre-terminated MPO components adopt humanized design for polarity maintenance and the TIA 568 standard provides three methods for configuring systems to ensure that proper connections are made. This white paper is intended to introduce polarity in MPO system and 40/100GbE polarization connectivity solutions in details. Polarity in MPO Components To maintain the correct polarity in MPO systems, the property of the components of MPO systems should be understood firstly. This part will introduce the basic components that are used in MPO system. MPO Connector To understand the polarity in 40/100 GbE transmission, the key of MPO technology MPO connector should be first introduced. MPO connector usually has 12 fibres. 24 fibres, 36 fibres and 72 fibres are also available. Each MTP connector has a key on one of the flat side added by the body. When the key sits on the bottom, this is called key down. When the key sits on the top, this is referred to as the key up position. In this orientation, each of the fibre holes in the connector is numbered in sequence from left to right and is referred as fibre position, or P1, P2, etc. A white dot is additionally marked on one side of the connector to denote where the position 1 is. (shown in the following picture) The orientation of this key also determines the MTP cable's polarity. MPO Adaptor MPO (male) connectors are mated to MPO(female) connectors using a MPO adaptor. As each MPO connector has a key, there are 2 types of MPO adaptors: Type A key-up to key-down. Here the key is up on one side and down on the other. The two connectors are connected turned 180 in relation to each other. Type B key-up to key-up. Here both keys are up. The two connectors are connected while in the same position in relation to each other. White Paper MPO Technology Connectivity & Application v1.0 2

MPO Cables MPO trunk cable with two MPO connectors (male/female) on both side of the cable serves as a permanent link connecting the MPO modules to each other, which is available with 12, 24, 48, 72 fibres. MPO harness cable, which is terminated with a male/female connector on the MPO side and several duplex LC/SC connectors on the other side, provides a transition from multi-fibre cables to individual fibres or duplex connectors. MPO Cassette Modular MPO cassette is enclosed unit that usually contains 12 or 24-fibre factory terminated fan-outs inside. It enables the user to take the fibres brought by a trunk cable and distribute them to a duplex cable with a MPO connector (at the rear) to the more common LC or SC interface (on the front side). The following is a MTP cassette with 6 duplex LC interface and a MTP connector. Three Cables for Three Polarisation Methods The three methods for proper polarity defined by TIA 568-C.3 standard are named as Method A, Method B and Method C. To match these standards, three type of MPO truck cables with different structures named Type A, Type B and Type C are being used for the three different connectivity methods respectively. In this part, the three different cables will be introduced firstly and then the three connectivity methods. MPO Trunk Cable Type A: Key Up to Key Down MPO Polarity Type A cable also known as straight cable, is a straight through cable with a key up MPO connector on one end and a key down MPO connector on the opposite end. This makes the fibres at each end of the cable have the same fibre position. For example, the fibre located at position 1 (P1) of the connector on one side will arrive at P1 at the other connector. The fibre sequence of a 12 fibre MPO Type A cable is showed as the following: The TIA spec for cabling (TIA-568) has more than 20 pages of possible combinations for MPO cable plants, varying in pins/no-pins, keying, types of connectors, color codes and numbering schemes. To understand the issues, let s start with the standard fiber color codes. White Paper MPO Technology Connectivity & Application v1.0 3

MPO Trunk Cable Type B: Key Up to Key Up Type B cable (reversed cable) uses key up connector on both ends of the cable. This type of array mating results in an inversion, which means the fibre positions are reversed at each end. The fibre at P1 at one end is mated with fibre at P12 at the opposing end. The following picture shows the fibre sequences of a 12 fibre Type B cable. The following part illustrates how the components in MPO system are used together to maintain the proper polarization connectivity, which are defined by TIA standards. Method A: The connectivity Method A is shown in the following picture. A type-a trunk cable connects a MPO module on each side of the link. In Method A, two types of patch cords are used to correct the polarity. The patch cable on the left is standard duplex A-to-B type, while on the right a duplex A-to- A type patch cable is employed. MPO Trunk Cable Type C: Key Up to Key Down (Fibre Crossed) Type C cable (pairs flipped cable) looks like Type A cable with one key up connector and one key down connector on each side. However, in Type C each adjacent pair of fibres at one end are flipped at the other end. For example, the fibre at position 1 on one end is shifted to position 2 at the other end of the cable. The fibre at position 2 at one end is shifted to position 1 at the opposite end etc. The fibre sequence of Type C cable is demonstrated in the following picture. MPO and MTP are the MT series. Small size, multichannel is the most prominent feature, which greatly facilitates the high-density wiring. The MT s Method B: In Connectivity Method B, a Type B truck cable is used to connect the two modules on each side of the link. As mentioned, the fibre positions of Type B cable are reversed at each end. Therefore, standard A-to-B type duplex patch cables are used on both sided. Three Connectivity Methods Different polarity methods use different types of MTP trunk cables. However, all the methods should use duplex patch cable to achieve the fibre circuit. The TIA standard also defines two types of duplex fibre patch cables terminated with LC or SC connectors to complete an end-to-end fibre duplex connection: A- to-a type patch cable a cross version and A-to-B type patch cable a straight-through version Method C: The pair-reversed trunk cable is used in Method C connectivity to connect the MPO modules one each side of the link. Patch cords at both ends are the standard duplex A-to-B type. White Paper MPO Technology Connectivity & Application v1.0 4

Upgrade to 40/100GbE With Correct Polarity The using of MPO/MTP connectors for 40/100G transmission is achieved with multimode fibre by transmitting multiple parallel 10G transmissions that will then be recombined when received. This method has been standardized. The following is to offer 40G transmission solution and 100G respectively. 40G Transmission Connectivity The 40G transmission usually uses 12-fibre MPO/MTP connectors. There are eight lanes within twelve total positions being employed for transmitting and receiving signals. Looking at the end face of the MPO/MTP connector with the key on top, the four leftmost positions are used to transmit, the four rightmost positions are used to receive, the four in the centre are unused. The following picture shows the optical lane assignments. (Tx stands for Transmit, Rx stands for Receive) This approach would transmit 40G using for parallel 10G lanes in each direction according to 40GBase-SR4. The second option is to use two 12-fibre MPO/MTP connectors side by side. The 10 positions in the centre of the connector on the left are used for transmitting and the centre 10 positions of the left are used for receiving. The third way of 100G transmission also uses two 12-fibre MPO/MTP connectors, but it uses the stacked layout as showed in the following figure. The ten centre positions of the top connector are used for receiving and the ten centre position of the bottom are used for transmitting. 100G Transmission Connectivity The 100G transmission over multimode requires a total of 20 fibres, 10 for transmitting and 10 for receiving. There are three options which is introduced as following: The first method is to use a 24-fibre MPO/MTP connector with the top centre 10 positions allocated for receiving and the bottom 10 position allocated for transmitting, as shown in the following figure. This method is recommended by IEEE. Understand Polarity in 40/100G Any transmit position should be connected to its own receive position. Here's an analogy to illustrate: Think of ball players. White Paper MPO Technology Connectivity & Application v1.0 5

You have pitchers & catchers. For 10G transmission, Pitcher 1 needs to throw to Catcher 1, Pitcher 2 to Catcher 2 and so on. (showed on the left side of the following picture) For 40/100G, any pitcher can throw to any catcher (showed on the right side of the following picture). But if you've got two catchers looking at each other as showed in the following picture, there isn't a whole lot happening. Conclusion Network designers using MPO/MTP components to satisfy the increasing requirement for higher transmission speed, during which one of the big problems polarity, can be solved by selecting the right types of MPO cables, MPO connectors, MPO cassette and patch cables. Considering the polarity method to be used and selecting the correct MPO/MTP components to support that methods, the proper solution for 40/100G transmission would be achieved with high density, flexibility and reliability. Notice: This white paper is for informational purposes only and is subject to change without notice. Datatronix makes no guarantees, either expressed or implied, concerning the accuracy, completeness or reliability of the information found in this document. Datatronix reserves the right to make changes to this document at any time, without notice, and assumes no responsibility for its use. This information document describes features that may not be currently available. Visit our website or contact the sales team for more information on features and product availability. - sales@datatronix.com White Paper MPO Technology Connectivity & Application v1.0 6