Thermocouple and RTD Modules for Compact FieldPoint

Similar documents
Digital Input Modules for Compact FieldPoint

Sound and Vibration Data Acquisition

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Sound and Vibration Data Acquisition

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

NI PXI/PXIe-2543 Specifications

FP-AI-112 and cfp-ai-112

STBART0200K standard analog input kit STB - 2 I - 15 bits + sign

USB Contents. Definitions SPECIFICATIONS. RF Power Sensor Device

Smart Cameras for Embedded Machine Vision

This document lists specifications for the PXI-5691 RF amplifier.

100 MHz, 100 MS/s, 14-Bit Digitizer

Topology 1-wire 16 Bank 8 1, 1-wire Octal 16 1, 1-wire Quad 32 1, 1-wire Dual 64 1, 1-wire 128 1

NI R Series Multifunction RIO Specifications

Specification Value Comments

PACSystems* RX3i Thermocouple Input Module, 12 Channels, IC695ALG412-CB

PACSystems* RX3i. Isolated Thermocouple Input Module, 6 Channels, IC695ALG306-EB Isolated Thermocouple Input Module, 12 Channels, IC695ALG312-EB

BNC-2120 INSTALLATION GUIDE. Connector Accessory for Multifunction DAQ Devices

This document lists specifications for the NI PXIe-1491 high-definition multimedia interface (HDMI) analyzer.

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Specifications describe the warranted, traceable product performance over ambient temperature ranges of 0 C to 55 C, unless otherwise noted.

R&S ZN-Z85 Switch Matrix Specifications

R&S TS-ISC In-System Calibration Kit On-site calibration solution for R&S CompactTSVP

WVR500 Waveform/Vector Monitor

Used for writing unscaled or raw data and covers the range from negative full scale (0) to positive full scale (65,535).

FP-QUAD-510. Features. Power Requirement OPERATING INSTRUCTIONS. 4-Axis, Quadrature Input Module

R Series for PXI Express Digital RIO with Kintex-7 325T FPGA. ni.com/manuals. may impair the protection the NI PXIe-7822R provides.

SIL-2 8-Ch Analog Input Series Thermocouple, High Level, Low Level

R1MS-GH3 BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL THERMOCOUPLE & DC INPUT MODULE MODEL. (8 points; isolated)

LabView Exercises: Part III

R&S ZN-Z154 Calibration Unit Specifications

2.7 GHz RF Vector Signal Analyzer with Digital Downconversion. This document lists specifications for the NI PXI-5661 RF vector signal analyzer.

Note In this document, the NI 9202 with spring terminal and the NI 9202 with DSUB are referred to inclusively as the NI 9202.

EX-IQ-Box Digital Signal Interface Module Specifications

R&S RT-Zxx High-Voltage and Current Probes Specifications

NI 9244 Datasheet DATASHEET. 3 AI/1 Neutral, 400 Vrms L-N/690 Vrms L-L, 24 Bit, 50 ks/s/ch Simultaneous

R&S TS-PMB Switch Matrix Module High-density, 90-channel, full matrix relay multiplexer module

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter

R&S RT-Zxx High-Bandwidth Probes Specifications

R&S TS-PSM3 High-Power Switching Module Automotive DUT supply and load switching up to 30 A

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

3500/42E Vibration Monitor

MAP110 AC-DC Series Data Sheet

R&S TS-PSM5 High-Power Switching Module Automotive DUT supply and load switching up to 50 A

Specifications. Reference Documentation. Performance Conditions

DATA SHEET. The Advantys model STBDAI5260 Digital Input Module provides 2 isolated discrete input points that operate on a 115 VAC power source.

Triple RTD. On-board Digital Signal Processor. Linearization RTDs 20 Hz averaged outputs 16-bit precision comparator function.

R&S ZN-Z151/-Z152/-Z153 Calibration Unit Specifications

UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4

Agilent Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Data Sheet

PicoScope 3000 Series Automotive User guide

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O

R&S ZV-Z81 Multiport Test Set, models.05/.09/.29 Specifications

Datasheet. LED Transformers. LED Transformer 120W 24V V. LED Transformers

Supplement. TDS1000 and TDS2000 Series User Manual Specifications Update

ArmorPOINT RTD and Thermocouple Input Modules

Technical Information RIA45

Chromalog T. Technical Information. Paper recorder Mulit-channel strip chart recorder with digital measured value display

NI 9238 Datasheet DATASHEET. 4 AI, ±500 mv, 24 Bit, 50 ks/s/ch Simultaneous

Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Technical Specifications

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

Single output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements.

PicoScope 4000 Automotive PC Oscilloscopes

Instructions. P MHz 1X/10X Passive Probe

ANALOG I/O MODULES AD268 / DA264 / TC218 USER S MANUAL

CONDITIONER TERMINAL BLOCK 8 ISOLATED ANALOG INPUTS STB 582

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area

MicroLogix 1200 Thermocouple/mV Input Module

SNAP Analog Input Modules. SNAP Analog Input Modules. Features. Description. Part Number

M4000 Diagnostic Test System For Power Apparatus Condition Assessment

Display Information Type Backlit blue on white STN Type

OM2000N INSTALLATION MANUAL

32 Channel CPCI Board User Manual

NI 9239 DATASHEET. 4 AI, ±10 V, 24 Bit, 50 ks/s/ch Simultaneous

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

SEL-3405 High-Accuracy IRIG-B Fiber-Optic Transceiver

R&S ZVA-Zxx Millimeter-Wave Converters Specifications

02/11/2015

Industriefunkuhren. Technical Manual. IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C / AFNOR NF S87-500

NI 9260 DATASHEET. 2 AO, 3 Vrms, 24 Bit, 51.2 ks/s/ch Simultaneous

National Park Service Photo. Utah 400 Series 1. Digital Routing Switcher.

FLIR CM82: 600 Amp Power Clamp Meter with VFD Mode

R&S TS-PFG Function Generator Module Dual-channel arbitrary waveform generator with isolated outputs

R&S ZN-Z103 Calibration Unit Specifications. Data Sheet V02.01

Agilent 87405C 100 MHz to 18 GHz Preamplifier

E4416A EPM-P Series Single Channel Power Meter

ThinkRF D GHz RF Downconverter

R&S ZND Vector Network Analyzer Specifications

FX-4AD-TC SPECIAL FUNCTION BLOCK USER'S GUIDE

PicoScope PC Oscilloscopes. User's Guide. ps2203.en r4 Copyright Pico Technology Limited. All rights reserved.

FLIR CM82: 600 Amp Power Clamp Meter with VFD Mode

Advantys STB DATA SHEET. Advantys STB Output Module. Description. Features

RIA45. Technical Information. Panel meter Digital panel meter with control unit for monitoring and visualizing analog measured values

BL67 electronic module 2 analog inputs for thermoelements BL67-2AI-TC

INTRODUCTION TERMINAL LAYOUTS FX2N-4AD-TC SPECIAL FUNCTION BLOCK USER S GUIDE

MKH 8060 Directional studio microphone

RMA42. Technical Information

R&S DST200 RF Diagnostic Chamber Specifications

PMG. Vibration Energy Harvesters

R&S ZVA110 Vector Network Analyzer Specifications

Transcription:

Thermocouple and Modules for Compact FieldPoint NI cfp-tc-120, NI cfp-tc-125, NI cfp--122, NI cfp--124 8 temperature inputs Thermocouple or millivolt 2-, 3-, or 4-wire Built-in signal conditioning between channels 250 V common-mode isolation on cfp-tc-125 50 and 60 Hz noise rejection 16-bit resolution Input ranges configurable in software for each channel 2,300 V rms for transient overvoltage protection Hot-swappable with autoconfiguration -40 to 70 C operating range Module Input Channels Resolution (bits) Input Type Input Ranges Software- Configurable per Channel 50/60 Hz Noise Filter All-Channel Update Period Common-Mode Between Channels Safety Isolation cfp-tc-120 8 16 Thermocouple J,K,R,S,T,N,E, and B ± 25 mv, ±50 mv 1.13 s (0.88 Hz) 2,300 V rms Millivolt ±100 mv, -20 to 80 mv cfp-tc-125 8 16 Thermocouple J,K,R,S,T,N,E, and B 0.22 s (Filter Off) 250 V rms 2,300 V rms Millivolt -20 to 80 mv 0.99 s (Filter On) cfp--122 8 16 2-, 3-wire Pt 100, Pt 1,000 1.08 s (0.93 Hz) 2,300 V rms Resistance 0 to 400, 0 to 4000 Ω cfp--124 8 16 2-, 4-wire Pt 100 1.08 s (0.93 Hz) 2,300 V rms Resistance 0 to 400 Ω Overview The NI cfp-tc-12x and cfp--12x are versatile temperature input modules for Compact FieldPoint used to measure thermocouples, millivolt-level voltages, thermistors, and 2-, 3-, and 4-wire s. They are used in applications such as temperature chamber control, device testing, and process control. Thermocouples are low-cost, flexible temperature devices. sensors are used in applications for acquiring temperatures with high accuracy. Two- and 3-wire s work well for applications with short signal wires and low noise levels; 4-wire s are well-suited for applications with long signal wires or high noise levels. All of these I/O modules include overranging and onboard diagnostics to ensure troublefree installation and maintenance. The modules measure and linearize signals on board to return scaled values to your control or monitoring software. The cfp-tc-12x and cfp--12x modules have NIST-traceable calibration certificates (available upon request) to ensure accurate and reliable analog measurements. Compact FieldPoint Compact FieldPoint is designed for industrial control applications that perform advanced embedded control, data logging, headless operation, and Ethernet connectivity. Compact FieldPoint, a rugged, reliable NI platform, is designed for industrial and mobile environments with high shock, vibration, and temperature extremes. Isolation The cfp-tc-125 provides 250 V rms common-mode voltage protection between channels, and all cfp-tc-12x and cfp--12x modules feature optical with 2,300 V rms of breakdown isolation. In addition, the cfp-tc-12x and cfp--12x offer double insulation for up to 250 V rms of operational isolation. You can safely use Compact FieldPoint with the cfp-cb-1 or cfp-cb-3 connector block in applications where hazardous voltages are present.

Thermocouple and Modules for Compact FieldPoint Smart I/O Modules The cfp-tc-12x and cfp--12x modules offer 16-bit resolution for high-accuracy measurements, and you can connect directly to industrial sensors or units under test with the safety isolation available. The modules filter, calibrate, and scale raw sensor signals to engineering units, as well as perform self-diagnostics to look for problems such as open thermocouples. With cfp-tc-12x and cfp--12x modules, your software application reads a linearized, calibrated, scaled value from the I/O module, eliminating the error-prone step of converting binary values to temperature. For increased accuracy and noise rejection, the modules use a16-bit delta-sigma analog-to-digital converter (ADC) with an integrated notch filter on each channel, which is configured for 50 and 60 Hz rejection. With high-accuracy 16-bit delta-sigma ADCs on the I/O modules, you also get instrument-quality measurements on an industrially rugged, distributed, embedded system. The cfp-tc-12x and cfp--12x modules offer a variety of update rates to fit your application, ranging from 0.22 s with filters off and 1.08 to 1.13 s with filters enabled. Overall data throughput depends on filter settings across all channels, software loop speeds, and network speeds. cfp-tc-120 The cfp-tc-120 includes eight differential inputs for thermocouples. It also provides cold-junction compensation using a thermistor embedded in the connector block. An onboard microcontroller compensates and linearizes the thermocouple reading to the NIST ITS-90 standard, using an advanced linearization routine for maximum accuracy. cfp-tc-125 In addition to the thermistor and linearization features of the cfp-tc-120, the cfp-tc-125 provides 250 V rms of common-mode rejection, ideal for applications where differences in voltages might exist between connected thermocouples. The cfp-tc-125 also offers 0.22 s update rates when the 50/60 Hz filter is not enabled. cfp--122 The cfp--122 includes eight inputs for 2- and 3-wire s. The module uses a stable current source for sensor excitation and an onboard microcontroller that linearizes and scales the measurements to temperature units. You can configure each channel of the module to return data scaled to temperature ( C, F, or K) or resistance. The 3-wire configuration used with the cfp--122 eliminates errors caused by lead wire resistance but does not reduce errors caused by noise. If your application involves high noise or long wires, you should use 4-wire s with the cfp--124. cfp--124 The cfp--124 includes eight inputs for 2- and 4-wire s. The module uses a stable current source for sensor excitation and an onboard microcontroller that linearizes and scales the measurements to temperature units. You can configure each channel of the modules to return data scaled to temperature ( C, F, or K) or resistance. Four-wire s used with the cfp--124 are ideal for applications involving long signal wires or high signal noise. The 4-wire configuration eliminates the voltage drop caused by lead wire resistance and reduces errors caused by noise. Isothermal Connectivity for cfp-tc-12x Modules For maximum accuracy, NI recommends using an isothermal connector block with a cfp-tc-12x. The cfp-cb-3 isothermal connector block minimizes the temperature gradient across wiring connections, improving the accuracy of the cold-junction measurement, and, therefore, of thermocouple measurements. Compact FieldPoint I/O Connections Compact FieldPoint modules include a built-in power distribution bus that provides multiple power connections on the module. A field-wired power supply connected to the voltage (V) and common (C) terminals is internally connected to a power distribution bus that features additional breakout terminals for voltage supply (VSUP) and common (COM). These terminals offer a convenient way to distribute power to field devices that require external power. Each cfp-tc-12x input channel has two terminals for differential input: 1. Thermocouple positive input (IN+) 2. Thermocouple negative input (IN-) Each cfp--122 input channel has three terminals: 1. Excitation output (EXCITE) 2. Sensing input (SENSE) 3. Common input (COM) Each cfp--124 input channel has four terminals: 1. Excitation output (EXCITE) 2. Positive sensing input (SENSE+) 3. Negative sensing input (SENSE-) 4. Common input (COM) BUY ONLINE at ni.com or CALL 800 813 3693 (U.S.) 2

Thermocouple and Modules for Compact FieldPoint 2-Wire 3-Wire Short Jumper Wire EX+ (Ch 0) SENSE (Ch 0) COM (Ch 0) EX+ (Ch 1) SENSE (Ch 1) COM (Ch 1) 2-Wire 3-Wire Short Jumper Wire Short Jumper Wires EXCITE+ (Ch 0) SENSE+ (Ch 0) SENSE (Ch 0) COM (Ch 0) EXCITE+ (Ch 1) SENSE+ (Ch 1) SENSE (Ch 1) COM (Ch 1) Leave this wire unconnected 4-Wire EX+ (Ch 7) SENSE (Ch 7) COM (Ch 7) [c]fp--122 Figure 1. Wiring Diagram for cfp--12x 4-Wire EXCITE+ (Ch 7) SENSE+ (Ch 7) SENSE (Ch 7) COM (Ch 7) [c]fp--124 V C Thermocouple IN(+) IN( ) Shield Figure 2. Wiring Diagram for cfp-tc-120 To Next Channel cfp-tc-120 Thermocouple IN(+) IN( ) Ordering Information NI cfp-tc-120...777318-120 Shield Figure 3. Wiring Diagram for cfp-tc-125 Note: Connections depend on the application. cfp-tc-125 NI cfp-tc-125...777318-125 NI cfp--122...777318-122 NI cfp--124...777318-124 Recommended System Products NI cfp-2120...777317-2120 NI cfp-1804...779490-01 NI cfp-bp-4...778617-04 NI cfp-cb-1...778618-01 NI cfp-cb-3...778618-03 NI PS-5 Power Supply...778805-90 BUY NOW! For complete product specifications, pricing, and accessory information, call 800 813 3693 (U.S.) or go to ni.com/advisors. BUY ONLINE at ni.com or CALL 800 813 3693 (U.S.) 3

Thermocouple and Modules for Compact FieldPoint Specifications Typical for -40 to 70 C unless otherwise noted. Input Characteristics Number of inputs... 8 ADC resolution... 16 bits, 1 in 65,536 Type of ADC... Delta-sigma Filters... 50/60 Hz rejection Excitation current cfp--122... 0.25 ma cfp--124... 2 ma Data scaling options cfp-tc-120... Temperature ( C, F, K) or mv cfp--12x... Temperature ( C, F, K) or resistance (Ω) Update period, all channels cfp-tc-125 Filter off... 0.22 s Filter on... 0.99 s cfp-tc-120... 1.13 s cfp--12x... 1.08 s Signal input bandwidth cfp-tc-120... 3 Hz cfp-tc-125... 12 Hz Cold-junction accuracy cfp-tc-12x With cfp-cb-3 connector block... 0.25 C typ, 0.5 C max Input impedance (cfp-tc-12x)... 20 MΩ Input current (cfp-tc-12x)... 35 na typ, 140 na max Input noise... ±1 LSB pp Overvoltage protection cfp-tc-120... ±40 V cfp-tc-125... ±250 V Common-mode voltage between channels referenced to isolated ground cfp-tc-125... 250 V cfp-tc-120... 1 V cfp--12x... 2 V Safety Isolation Voltage Maximum safety isolation voltage... Channel-to-channel safety isolation... Transient overvoltage... Physical Characteristics LED indicators POWER (green)... READY (green)... OPEN TC <0..7> (red) (cfp-tc-12x)... Dimensions... 250 V rms, Installation Category II (cfp-tc-12x only) No isolation between channels 2,300 V rms Power on and self-test passed Module configured and ready Open or broken thermocouple on channel 128 by 88 by 25 mm (5.0 by 3.5 by 1.0 in.) Weight cfp-tc-120... cfp-tc-125... cfp--12x... Power Requirement Power from network module cfp-tc-120... cfp-tc-125... 130 g (4.6 oz) 125 g (4.4 oz) 110 g (3.7 oz) 350 mw 650 mw Environmental Operating temperature... -40 to 70 C Storage temperature... -55 to 85 C (cfp-tc-125-40 to 80 C) Relative humidity... Maximum altitude... Pollution degree... 2 Shock and Vibration Operating vibration, random (IEC 60068-2-64)... Operating vibration, sinusoidal (IEC 60068-2-6)... Operating shock (IEC 60068-2-27)... Safety and Compliance 10 to 90%, noncondensing 2,000 m; at higher altitudes the isolation voltage ratings must be lowered 10 to 500 Hz, 5 g rms 10 to 500 Hz, 5 g 50 g, 3 ms half sine, 18 shocks at 6 orientations; 30 g, 11 ms half sine, 18 shocks at 6 orientations Safety This product is designed to meet the requirements of the following standards of safety for electrical equipment for measurement, control, and laboratory use: IEC 61010-1, EN 61010-1 UL 61010-1, CSA 61010-1 Note: For UL and other safety certifications, refer to the product label or visit ni.com/certification, search by model number or product line, and click the appropriate link in the Certification column. Electromagnetic Compatibility This product meets the requirements of the following EMC standards for electrical equipment for measurement, control, and laboratory use: EN 61326 (IEC 61326): Class A emissions; Industrial immunity EN 55011 (CISPR 11): Group 1, Class A emissions AS/NZS CISPR 11: Group 1, Class A emissions FCC 47 CFR Part 15B: Class A emissions ICES-001: Class A emissions BUY ONLINE at ni.com or CALL (800) 813 3693 (U.S.) 4

Thermocouple and Modules for Compact FieldPoint CE Compliance This product meets the essential requirements of applicable European Directives, as amended for CE marking, as follows: 2006/95/EC; Low-Voltage Directive (safety) 2004/108/EC; Electromagnetic Compatibility Directive (EMC) Note: Refer to the Declaration of Conformity (DoC) for this product for any additional regulatory compliance information. To obtain the DoC for this product, visit ni.com/certification, search by model number or product line, and click the appropriate link in the Certification column. Waste Electrical and Electronic Equipment (WEEE) EU Customers: At the end of their life cycle, all products must be sent to a WEEE recycling center. For more information about WEEE recycling centers and National Instruments WEEE initiatives, visit ni.com/environment/weee.htm. BUY ONLINE at ni.com or CALL (800) 813 3693 (U.S.) 5

NI Services and Support MAINTAIN DEPLOY SERVICE NEEDS Training and Certification NI has the services and support to meet your needs around the globe and through the application life cycle from planning and development through deployment and ongoing maintenance. We offer services and service levels to meet customer requirements in research, design, validation, and manufacturing. Visit ni.com/services. NI training is the fastest, most certain route to productivity with our products. NI training can shorten your learning curve, save development time, and reduce maintenance costs over the application life cycle. We schedule instructor-led courses in cities worldwide, or we can hold a course at your facility. We also offer a professional certification program that identifies individuals who have high levels of skill and knowledge on using NI products. Visit ni.com/training. Professional Services Our NI Professional Services team is composed of NI applications and systems engineers and a worldwide National Instruments Alliance Partner program of more than 600 independent consultants and integrators. Services range from start-up assistance to turnkey system integration. Visit ni.com/alliance. OEM Support PLAN DEVELOP We offer design-in consulting and product integration assistance if you want to use our products for OEM applications. For information about special pricing and services for OEM customers, visit ni.com/oem. Local Sales and Technical Support In offices worldwide, our staff is local to the country, giving you access to engineers who speak your language. NI delivers industry-leading technical support through online knowledge bases, our applications engineers, and access to 14,000 measurement and automation professionals within NI Developer Exchange forums. Find immediate answers to your questions at ni.com/support. We also offer service programs that provide automatic upgrades to your application development environment and higher levels of technical support. Visit ni.com/ssp. Hardware Services System Assurance Programs NI system assurance programs are designed to make it even easier for you to own an NI system. These programs include configuration and deployment services for your NI PXI, CompactRIO, or Compact FieldPoint system. The NI Basic System Assurance Program provides a simple integration test and ensures that your system is delivered completely assembled in one box. When you configure your system with the NI Standard System Assurance Program, you can select from available NI system driver sets and application development environments to create customized, reorderable software configurations. Your system arrives fully assembled and tested in one box with your software preinstalled. When you order your system with the standard program, you also receive systemspecific documentation including a bill of materials, an integration test report, a recommended maintenance plan, and frequently asked question documents. Finally, the standard program reduces the total cost of owning an NI system by providing three years of warranty coverage and calibration service. Use the online product advisors at ni.com/advisor to find a system assurance program to meet your needs. Calibration Services NI recognizes the need to maintain properly calibrated devices for highaccuracy measurements. We provide manual calibration procedures, services to recalibrate your products, and automated calibration software specifically designed for use by metrology laboratories. Visit ni.com/calibration. Repair and Extended Warranty NI provides complete repair services for our products. Express repair and advance replacement services are also available. We offer extended warranties to help you meet project life-cycle requirements. Visit ni.com/services. ni.com 800 813 3693 National Instruments info@ni.com 2009 National Instruments. All rights reserved. CompactRIO, FieldPoint, National Instruments, National Instruments Alliance Partner, NI, and ni.com are trademarks of National Instruments. Other product and company names listed are trademarks or trade names of their respective companies. A National Instruments Alliance Partner is a business entity independent from National Instruments and has no agency, partnership, or joint-venture relationship with National Instruments. 2009-10741-161-101-D