WE-EF LEUCHTEN. Technical information for Eco Step Dim Basic. Product ID

Similar documents
Supply voltage 230 V AC Service button 1. Power connector Light track contacts Service LED 1, red

LED control gear Compact dimming. Uconverter LCAI 2x38 W 0500 K013 one4all ECO series. Ordering data

OPTOTRONIC Intelligent

Operating instructions III / 2004

SINGLE ZONE CLIMATE ZONING SYSTEM. Technical Manual. Polyaire Pty Ltd

LED Driver Linear / area fixed output

15 Series - Dimmer

LED Driver Compact dimming

02/11/2015

LED Driver Compact fixed output

HYL-035D0850G103. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

Mosaic TM Dimmer 3 x 1000 W

Dimmers SЕRIES. Kitchen light control. Bedroom light control. Living room light control

Gamma instabus. Technical product information

ArteorTM Dimmer 3 x 1000 W / /60

LED Driver Linear / area dimming industry. Driver LC 200W 1050mA UNV ADV IND ADVANCED series

HYL-080D1750G358. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

TRF STEP-DOWN TRANSFORMER USER MANUAL

OT 100/ /700 P5

Technical Information

PRODUCT DATASHEET QTi DALI-T/E 2X18 42 DIM

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

LED control gear Compact fixed output. Uconverter LCI 55 W 1400 ma O010 TOP series Ø4,4. Ordering data

Assembly. Front view. LEDs. Parametrization interface. Power Bus

Series CT7N Bimetallic Overload Relays

HID control gear Electronic. PCIS, PCS outdoor FOX B011 PCI outdoor. Ordering data. Circuit power1. tc/ta for 60,000 h For luminaires with 1 lamp

Model Number Structure

HELVAR. CONTROLLABLE ELECTRONIC BALLASTS DALI & 1-10 V controllable ballasts STANDARD ELECTRONIC BALLASTS

Spectra Batten (Order code: LEDJ95)

Contactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122

OPERATING MANUAL. DMX / DSI / DALI Dekoder 3004B-H Mk2

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

LED Driver Compact fixed output

For installation queries contact Customer Services (0) TCR IP 4 Operating instructions

LED Driver Compact fixed output

english SGC inverter series hf transformer input voltage up to 800 V touch screen built-in data loggers

System 2000 System 2000 HLK relay insert. 1 Safety instructions. 2 Device components. 3 Function. Order No. : Operating instructions

PHASED OUT. LED control gear Compact fixed output. Driver LC 40W 900mA fixc C SNC China Domestic ESSENCE series

Kuhnke Technical Data. Contact Details

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01

Operating Manual. Basic Control BC16. two-channel for eco moon

LED Driver Compact dimming

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

Emergency lighting units EM powerled

LED Driver Compact dimming

Figure 1: Device components

Fiber-Optic Sensor Amplifiers E3S-X3, E3X-NL and E3X-NM Discontinued March 2012; Revised Replacements

LED control gear Compact fixed output

OUT. HID control gear Electronic. PCIS, PCI, PCS outdoor DIM B011 PCI outdoor

Dragonfly Quad. User Manual V1.4. Order code: EQLED101

SubstiTUBE Value ST8V-0.6m

HID control gear Electronic

(1) (2) (3) Bedienungs- und Montageanleitung. Safety instructions. Structure of the device

Description Set value in neutral conductor is synchronous with set value Ir of main pole. R.m.s. value measurement and thermal memory CSA 100

120cm (4x36 Watt) incl. Splitter Instruction Manual

PHASED OUT. HID control gear Electronic. PCIS, PCI, PCS outdoor DIM chronostep PCI outdoor

Modular pulse operated latching relay 16 A

MULTIS L72. Operating instructions

Quick-disconnect cables. Adjustable mounting brackets

Operating Instructions Dimmer for V Incandescent Lamps

Ordering details. Approval. Classification

Industriefunkuhren. Technical Manual. IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C / AFNOR NF S87-500

SubstiTUBE Advanced UO EM ST8AU-1.5m-24W-EM

Catalogue Ignitors and power switches for HID

USER MANUAL. Compact dimensions 6 DIN modules, with 4 LED s display with 7 segments, for an excellent reading of the measurements

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

Datasheet - SRB301LC 24VAC/DC

IP Roombox. Hotel Room Management

3M Sensored Termination (15 kv) QX-T15I-vi1-E

E-CORE LED DOWNLIGHT 3000 DATA SHEET 1 / 7. Application:

DATA SHEET Panorama Rudder Indicator, TRI-2

REGO Start&Go USER MANUAL

Single-phase bidirectional energy meter with S0 pulse output

TRANSCENSION 6-CHANNEL DMX DIMMER PACK (order code: BOTE40) USER MANUAL

Cyclo Series. user manual. MartinArchitectural

LED Driver Linear / area dimming

CHECK LINE. Model LS-36-LED. Stationary Stroboscope. Operating Manual BY ELECTROMATIC

Generator protection relay

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC

SubstiTUBE Value ST8-HV5

KHT 1000C HV-Probe Calibrator. Instruction Manual

Operating Instructions 07/2007 Edition. SINAMICS G130/G150 Line harmonics filter. sinamics

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell

Siteco Service Box User Manual 1/31

DALI TOUCHPANEL BASIC TW. Operating and control unit

LC1D12P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A V AC coil

Gardner Liquid Color Standards Instruction Manual

Secto Design Oy Kauppalantie Kauniainen Finland tel fax

Emergency lighting units EM powerled

Automatic Test System AT-S + with STAR + Technology Features

Arc Detecting and Protection System

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

SINAMICS G130 / G150. Line harmonics filter. Operating Instructions 05/2010 SINAMICS

User Manual CC DC 24 V 5A. Universal Control Unit UC-1-E. General Information SET. Universal Control Unit UC-1 Of Central Lubrication PAUSE CONTACT

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

Description Set value in neutral conductor is synchronous with set value Ir of main pole. CSA 100. conductor. I r A 50-63

Transcription:

WE-EF LEUCHTEN Technical information for Eco Step Dim Basic Product ID 430-0001

Eco Step Dim Basic General information All WE-EF Eco Step Dim components are intended for professional users. Installation and start-up may only be performed by persons with the relevant technical knowledge. Please read these instructions carefully before installing and starting up the system. It is the only way to ensure safe and proper operations. Please keep these instructions on file, so they are available for later use if required. WE-EF is not liable for the incorrect connection and the improper use of its products. The reliable functioning of Eco Step Dim products requires that they have been programmed and started up accordingly. Safety information All works on the equipment may only be carried out after power to the equipment has been disconnected. The applicable safety and accident prevention provisions must be adhered to. The improper opening of the products is not permitted; there is danger to life due to electrical voltage. Repairs may only be performed by the manufacturer. The electronic ballast loses its zero-potential once the controller is connected to the control input. Eco Step Dim Basic Schema Electronic Controller integral (included in delivery) Switchboard Hand Held Programmer Adaptor Software Download www.we-ef.com Phase line Optional for On-site-Programming Hand Held Programmer incl. Adaptor and Software: 405-0122 WE-EF Eco Step Dim Basic requires an external switch phase. The switch phase may come from any source. A pre-programmed capacity level is turned on and off in the luminaire by connecting or disconnecting the control phase. When the control phase is turned off, the luminaire changes to dimming mode. The electronic controller can be updated without limitations, and the firmware can be adapted or re-imported as necessary. This requires a hand-held programming device and application software, which are not included in the delivery scope. Please contact your WE-EF representative or the technical WE-EF Hotline at +49 5194 909209 (Monday to Friday from 8:00 am to 4:00 pm). 1

Eco Step Dim Basic Electronic Controller The electronic controller is already built into the luminaire by WE-EF, and is delivered ready-made in accordance with customer requirements (see Form Sheet in the Appendix). The dimming level can also be adjusted at a later time. The configuration of the connection line can be found in the illustrations below. The electronic controller is suited for installation in IP66 luminaires. Technical data Input voltage:....................... 230VAC +/-10% AC Line frequency...................... 50 Hz (+1 % / -2 %) Power consumption................... <0.5W PF=0,1 Galvanic separation................... No potential separation input to output As soon as the electronic ballast is connected to the electronic controller, the control input is no longer galvanically separated. Switching current.................... 4A, λ = 0.8 Switch cycles........................ 50000, Function (I, λ) Programmable....................... Yes Can be parametrised.................. Yes Control output 1-10V................. Short-circuit proof Control output DALI................... Short-circuit proof, 2mA configured for a slave Connection clamps................... 0.5 to 1.5mm² Conductor type of connection clamp..... Single-wire, fine-wire Firmware Update / Parametrisation...... Via universal input without current with electronic controller Climatic conditions Operating temperature range Tc......... 25 C to +80 C Storage temperature range............. 25 C to +85 C Humidity........................... 90% non-condensing Standards Impulse withstand voltage............. 4kV / 1.2 / 50 according to DIN EN 61037 Protection class..................... SKI (SKII on request) Degree of protection.................. IP20 Enclosure Material........................... Plastic enclosure made of polycarbonate Dimensions......................... (W/H/D) 81 mm / 20 mm / 41 mm Weight............................. 32 g 2

Eco Step Dim Basic Connection diagram Eco Step Dim Basic Standard programming* 80% 60% D2 50% 40% 20% 0% ON** OFF** * For customised programming at the factory, please complete form on page 4 and submit to WE-EF with purchase order ** ON / OFF defined by user, using a dimmer switch (photocell) *** Cycle times for the phase is defined by the user 3

Eco Step Dim Basic Programming For customised programming at the factory, please enter the required dimming level in the "Customised Programming" table. WE-EF Standard Programming* WE-EF Standard Programming 80% Step Ramp Niveau 60% D2 50% 12 min. 100 % 40% D2 3 min. 50 % 20% 0% ON** OFF** * For customised programming at the factory, please complete form and submit to WE-EF with purchase order ** ON / OFF defined by user, using a dimmer switch *** Cycle times for the phase is defined by the user Individual Programming Step Ramp Niveau % D2 % will be completed by WE-EF Order number Lamp description Work steps Name Date File Name Program completed Program transferred Programm checked 4

Eco Step Dim Basic Accessories The accessories listed below can be used to make modifications (on-site programming). Hand-held programmer incl. Adaptor and Software.........WE-EF item number 405-0122 If you would like to speak with one of our experts, please contact us by e-mail: info.germany@we-ef.com 5

www.we-ef.com WE-EF LEUCHTEN Germany Tel +49 5194 909 0 Fax +49 5194 909 299 info.germany@we-ef.com Thailand Tel +66 2 738 9610 Fax +66 2 175 2174 info.asiapacific@we-ef.com WE-EF LUMIERE France Tel +33 4 74 99 14 44 Fax +33 4 74 99 14 40 info.france@we-ef.com Australia Tel +61 3 8587 0444 Fax +61 3 8587 0499 info.australia@we-ef.com WE-EF HELVETICA Switzerland Tel +41 22 752 49 94 Fax +41 22 752 49 74 info.switzerland@we-ef.com United States of America Tel +1 724 742 0030 Fax +1 724 742 0035 info.usa@we-ef.com United Kingdom Tel +44 844 880 5346 Fax +44 844 880 5347 info.uk@we-ef.com Eco Step Dim Basic_010416 / 006-1125 Technische Änderungen vorbehalten. Technical specifications are subject to change. WE-EF 2016