TECHNICAL SERVICE. DATE: August 02, 2007 ST

Similar documents
Chinook Gas Furnace Multi-Position High Efficiency Condensing Furnace

TECHNICAL GUIDE 95.5% AFUE SINGLE STAGE RESIDENTIAL GAS FURNACES MULTI-POSITION MODELS: TG9S

LEVEL CROSSING MODULE FOR LED SIGNALS LCS2

Electronic lubrication control unit

SHUTTLE WITH INFRA-RED DETECTION SAS2-IR

DLP600M 6+1 Relay Module for Heating and Cooling Plants

The UK sequence is shown below. The duration of each phase can be easily adjusted during the programming to suit.

DLP200M 2 Relay Module for Heating and Cooling Plants

80G1 PRODUCT SPECIFICATIONS GAS FURNACE SINGLE STAGE CONFIGURATIONS HEAT EXCHANGER DESIGN CABINET DESIGN AIR DELIVERY SYSTEM CONTROLS VENTING

ATTENTION YOUR NEW KEY FOBS WILL NOT WORK UNTIL YOU HAVE LOADED THEM ON TO YOUR REMOTE CONTROL SYSTEM

Upflow/ Horizontal Left/Right, Downflow Two Stage Condensing Gas Fired Furnace

Introduction Display...1 Mounting...1 Firmware Version...2. ADL Operation... 3

Dimming actuators GDA-4K KNX GDA-8K KNX

Master Time Clock MTC Users Manual

REGO Start&Go USER MANUAL

Safety Information. Camera System. If you back up while looking only at the monitor, you may cause damage or injury. Always back up slowly.

BC-R25 Series. Burner Controllers

C-net WIND. User s Guide

SINGLE ZONE CLIMATE ZONING SYSTEM. Technical Manual. Polyaire Pty Ltd

3214NXT. Service Manual. IMPORTANT: Fill in Pertinent Information on Page 3 for Future Reference

TRIPLETT. PairMaster. Lan Cable Test Set. Instruction Manual

Submittal. Downflow Two Stage Condensing Gas Fired Furnace 120,000 BTUH S9V2D120D5-SUB-1-EN. March 2016 S9V2D120D5PSAA TAG:

A801D PRODUCT SPECIFICATIONS SINGLE STAGE GAS FURNACE INSTALLATION FEATURES

Be sure to check the camera is properly functioning, is properly positioned and securely mounted, every time you operate your vehicle.

GeniSys Display. Contractor s Tool. Description / Applications. for the GeniSys Advanced Burner Control

User interface. Abbreviations / Meanings

Digital Economy Seven Programmer

Catalogue Ignitors and power switches for HID

OPERATOR S. MODEL Computron 8000 PRESSURE FRYER REGISTER WARRANTY ONLINE AT

VLC-3 USER'S MANUAL. Light Program Controller. M rev. 04 K rev. 00 & ( ( 5, 352*5$0 1 : $ 2 ' 6(77,1*6 )81&7,216

FORM EF /96 REV:

BLOCK OCCUPANCY DETECTOR

RSSL1:1-KuXER. Outdoor Unit (ODU) Ku Ext Ref LNB Redundancy System with external 10 MHz Reference System. Mux/Tee. Coax cable

OWNER'S MANUAL KIT INCLUDES. 3M VHB Mounting Pad Mounting Hardware PART # 40040

12.1 Control Description (see Figure 4) Dual 7-Segment LED. Y1 red LED (solid on) indicates Y1 call from thermostat is present. Line Voltage Connector

LED Sign Installation Instructions

OPERATOR S GUIDE OPERATOR S GUIDE OPERATOR S GUIDE OPERATOR S GUIDE OPERATOR S GUIDE OPERATOR S GUIDE OPERATOR S GUIDE.

USER GUIDE for the. HES92020, HES92021, HES92220 & HES92221 DIMMER Modules

Light-It Decoder p/n Lighting decoder w/built-in white LED

Split System Air Conditioner

Dimming actuators of the FIX series DM 4-2 T, DM 8-2 T

A Motor can be in many groups, by assigning additional channel# on it.

EA63-7D. Generator Automatic Voltage Regulator Operation Manual. Self Excited Automatic Voltage Regulator

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

POINTS POSITION INDICATOR PPI4

PLC Control Unit for a CSM-E Electrical Compact Clean Steam Generator

HID control gear Electronic. PCIS, PCS outdoor FOX B011 PCI outdoor. Ordering data. Circuit power1. tc/ta for 60,000 h For luminaires with 1 lamp

Ultra Quiet Series Electric Air Handler

Comfort System T-32-P Universal Thermostat. Operation Manual

15 Series - Dimmer

Revision 1.2d

Fully ly Automaticti. Motorised Satellite t TV System. User s manual REV

Engineered to meet your needs T he oldest name in stud welding,

Bill of Materials: Super Simple Water Level Control PART NO

OWNERS MANUAL. Revision /29/ Lightronics Inc. 509 Central Drive Virginia Beach, VA Tel

Personal Information Page

Lesson Sequence: S4A (Scratch for Arduino)

User Manual CC DC 24 V 5A. Universal Control Unit UC-1-E. General Information SET. Universal Control Unit UC-1 Of Central Lubrication PAUSE CONTACT

EG4015. Digital Generator Governor Controller User Manual

RD RACK MOUNT DIMMER OWNERS MANUAL VERSION /09/2011

STX Stairs lighting controller.

Christmas LED Snowflake Project

Ford 6.4L Powerstroke Installation Instructions

Build A Video Switcher

Defrost Control Installation and Programming of Version 3.1 Cards

21 Channel Light Show PWM LED Controller with Remote Control

Any feature not specifically noted as supported is not supported.

Dimmers SЕRIES. Kitchen light control. Bedroom light control. Living room light control

ART2000i Digital Dimming System. Installation guide. Stock number *8200-

FORENSIC CASEBOOK. By Bob Huddleston, Eastman Chemical Co. One of the most common. reasons for marriage failure

Film-Tech. The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment.

Residential SOLA TM S7910B Local Keyboard Display Module

Ratings at 0.8 power factor. Please refer to the output ratings technical data section for specific generator set outputs per voltage.

P1000P1/P1100E1 50Hz

Figure 1: Device components

24 Hour & 7 Day Digital Immersion Heater Timeswitch Article

P1350P1/P1500E1 50Hz

EZCOM-1. PLC - to - AMS MESSAGE DISPLAY INTERFACE INSTALLATION AND OPERATING INSTRUCTIONS. Rev March, 2001

TRIMBLE GPS / 10MHz REFERENCE MONITOR DISPLAY V January 2015

Troubleshooting Guide for the ESP MC controller Feb Royce Mason

GP-500 SERIES - Low Voltage

Identification - electrical services

Transfer Switch. OTECA (Spec A) OTECB (Spec A) OTECC (Spec A) OTECD (Spec A) Amperes. English Original Instructions (Issue 5)

PRELIMINARY Sunny Boy 240-US

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

INSTALLATION AND OPERATION M

Phone (440) Fax Wireless Rear Observation System With Night Vision Camera

USER & ENGINEER INSTRUCTION MANUAL

3200NT System 14. Service Manual. IMPORTANT: Fill in Pertinent Information on Page 3 for Future Reference

ALM-6813/6812 INSTALLATION AND PROGRAMMING MANUAL

SMC 3000 Series Master Clock Installation Manual (V2) Table of Contents

Passive UTP Transceiver Hub with Integral Camera Power Installation Guide

KBR-M -WARNING- -SPECIFICATIONS-

SquareLED - Aura Bar & Matrix Beam Light 100

PRE-INSTALLATION ELECTRICAL POWER GUIDE

Instruction Manual for Electronic Blowers and Flashboards

SOURCE COMMANDER MSS433 A/V SELECTOR OWNER S MANUAL INSTALLATION GUIDE

HS-509 VIBRATION TRIP MODULE

OWNERS MANUAL. Revision /01/ Lightronics Inc. 509 Central Drive Virginia Beach, VA Tel

AF-300 E11 Adjustable Frequency Drive

Transcription:

Unitary Products Group 5005 York Drive Norman, OK 73069 1/877-874-7378 TECHNICAL SERVICE DATE: August 02, 2007 ST-028-07 TO: All York Branches and Distributors All York Service Managers All Field Service Supervisors SUBJECT: White Rodgers/ Emerson Integrated Furnace Control (IFC) Boards On All Single and Two Stage Gas Furnaces As of July 1, 2007 (W0G7 furnace serial number prefix) all residential furnaces will have changed over to the new White Rodgers control boards. These boards are basically a drop in replacement for current production models. The new boards are larger than previous boards which may require drilling mounting holes to apply in older products. Instructions with a drilling template will be with each board. Single stage boards are 4 7/8 X 6 ½ and two stage boards are 4 7/8 X 8. Single Stage Latitude products utilize the Basic Board SAP# 265901. This board however will not be set up as a Source 1 Replacement Part. Only the two stage boards, P/N S1-33109167000 / 265902 will be provided from Source 1 for standardization purposes. Refer to Figure 1 below for basic board layout. (SAP# 265901 is the part number on the board) Single Stage Premium Products utilize the Two-Stage Cooling Board S1-33109167000 / 265902. It is a direct replacement for part numbers: 265901 (basic board above), 031-01933-000, 031-01267-00*, 031-00662-000, 031-01250-000, 031-01266-000, 031-01284-000, 031-01973-000 and 031-01972-000. See Fig 2. The Two Stage products with a PSC motor utilize a board P/N S1-33109168000 / 265903, which is a direct replacement for part numbers 031-01290-000 and 031-09117- 000. Refer to Figure 3. ECM motor furnace products, utilize a board P/N S1-33109169000 / 265904 which is also the replacement for part numbers 031-01909-000 (ignition) and 031-09118-000 (CFM); 031-09117-000 (ignition) and 031-01955-000 (CFM); 031-01911-000 (CFM) and 031-09169-000 (combined). Note: This board has the CFM board incorporated; Fig 4, in it so there is no separate CFM board. For temporary substitution of PSC motor when ECM motor or module are not available refer to ST-017-07 General Replacement Information: Refer to the electrical wire diagram for the furnace being serviced for circuit connections specific to that model. There can be a fault light even with the On Board fuse is blown. 1

Please copy and distribute the Fault Code Sheets on page 5 to 7 of this service letter. Fig 1: Single Stage Basic Board 265901 Fig 2: Single Stage Premium Board w/two Stages Cooling S1-33109167000/265902 Note: Use Y2/Y For Single Stage Cooling 2

Fig 3: Two Stage Board For PSC Motor Furnaces S1-33109168000/265903 Note: Use Y2/Y For Single Stage Cooling 3

Fig 4: Two Stage Board For ECM Motor Furnaces, Note: CFM Selection Jumpers Note: Use Y2/Y For Single Stage Cooling Ron Butcher Ron Butcher Field Service Supervisor Robert Cabrera Robert Cabrera Director of Heating Engineering 4

New White Rodgers/Emerson IFC Boards Fault Code/Flashes Single Stage Two Stage PSC Motor Two Stage ECM Motor Variable Speed 265901 & S1-33109167000 / 265902 S1-33109168000/265903 S1-33109169000/265904 No Power To Board, Fault Codes Possible With Blown On-Board Fuse Normal Operation No Call For Heat Steady Off Green Heart Beat 1 Amber Flash Normal Operation With Call For Heat, First Stage On 2 Stage 2 Amber Flash N/A Normal Operation With Call For Second Stage Heat 3 Amber Flash N/A W2 Present With No W1 4 Amber Flash Y Present With No G Call Rapid Amber Flash Low Flame Sense Current Solid LED Red Solid Internal GV Error, Micro, And Frequency Check Rapid Flash Red Rapid Twinning Error, Incorrect 24v Phasing 1 Flash Red * Flame Sensed When No Flame Should Be Present 2 Flash Red * Pressure Switch Stuck Closed/ Inducer Error 3 Flash Red * 1st-Stage Pressure Switch Stuck Open/ Inducer Error 3 Double Red * N/A 2nd-stage Pressure Switch Stuck Open/ Inducer Error 4 Flash Red * Open Limit Switch 5 Flash Red * ## Open Rollout/Open Fuse Detect 6 Flash Red * # Pressure Switch Cycle Lockout 7 Flash Red * # External Lockout (Retries) 8 Flash Red * # External Lockout (Recycles) 9 Flash Red Grounding Or Reversed Polarity, Transformer Leads Reversed 10 Flash Red * Gas Flow With No Call For Heat 11 Flash Red * ## Limit Switch Open More Than 5 Minutes Blower Failure 12 Flash Red Ignitor Failure * = Stored In Error Code Array; # = One Hour Soft Lockout; ## = Hard Lockout Fault Code Retrieval: To retrieve fault codes, push and release the LAST ERROR button for more than 1/5 second and less than 5 seconds. The LED will flash up to five stored fault codes, beginning with the most recent. If there are no fault codes in memory, the LED will flash two green flashes. The control will flash the most recent error first and the oldest error last (last in first out). There shall be 2 seconds between codes. Solid LED error codes will not be displayed. Fault Code Reset: To clear the fault code memory, push and hold the LAST ERROR button for at least five seconds. The LED will flash three green flashes when the memory has been cleared. 5

6

7