Digital Differential Pressure Gauge Switch 0.1 : 0.5 BAR USER GUIDE

Similar documents
Modular Lube Lubrication Systems System Controls

TDEPD. Field-Programmable Pressure Switch/Transducer with Integrated LED Display. Programming Sequence Manual

MF-PFT. Programmable differential pressure transmitter for pressure or flow measurement and control. DIL1 Output/Utsignal

The measurements are stored in non-volatile memory, which retains data even when the power down.

Operating Instructions

Projector Lift. User Guide INSTALLATION OPERATION SETUP PROGRAM IR REMOTE FACTORY RESET

DIGITAL TIMER - MODES- rev. 5.5

Installation & Operation Manual. BEC PM1 Controller Time/Flow/Volume Controller. Water Control Solutions

SINGLE ZONE CLIMATE ZONING SYSTEM. Technical Manual. Polyaire Pty Ltd

800 Displaying Series Flowmeter

User Guide. Centrex Recording Interface

1 Output 1 operation. 3 Pressure unit display. 4 Main display Large 4-character LCD display. 5 Sub-display Small 4-character LCD display.

VNS2210 Amplifier & Controller Installation Guide

ST8-WiFi Timer. Installation Guide and Operations Manual. English MIN M D YYYY

WIRING. Connection connector. NPN output type Standard type. Main circuit. High-function type. Main circuit. PNP output type.

Operating instructions Electronic preset counter Type series 717

Junior Max (JR Max ) Controller

USER MANUAL FOR THE ANALOGIC GAUGE FIRMWARE VERSION 1.0

ISC202 Quick Start Guide

Sensopress LCD Special English

T775U Series 2000 Electronic Stand-Alone Controller

STD-525T PRECISION TIMER

Overview: Specifications: Installation Instructions:

AP-40. AP-40 Series Features Industry s smallest-sensor head Ultra lightweight High-speed response Two-color LED digital pressure display

SPA MICROPROCESSOR SPEEDOMETER INSTALLATION AND OPERATING MANUAL PAGE 2...INSTRUMENT FEATURES PAGE 3...OPERATING INSTRUCTIONS PAGE 3...

T775U Series 2000 Electronic Stand-Alone Controller

AEROTRAK PORTABLE AIRBORNE PARTICLE COUNTER MODEL 9110 QUICK START GUIDE

VNS2200 Amplifier & Controller Installation Guide

LEVEL CROSSING MODULE FOR LED SIGNALS LCS2

Vorne Industries. 87/719 Analog Input Module User's Manual Industrial Drive Itasca, IL (630) Telefax (630)

SSPT724A Timer Quick Start Guide

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

REGO Start&Go USER MANUAL

HOBO H Energy Logger

ACT 10 Digital Keypad Operating & Installation Instructions This manual is found at

Signet 2250 Hydrostatic Level Sensor

Camera Setup Instructions

USER MANUAL FOR THE ANALOGIC GAUGE FIRMWARE VERSION 1.1

Model IQ4-PC User Manual Revision Date:

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell

Installation and Maintenance Instructions for GC51 Rangeable Pressure Transmitter

Quick Start Function Summary Instructions for ASHCROFT GC52 Differential Pressure Transmitter Version 6.03 Rev. B

TORK DGU100/DGUM100 7 DAY DIGITAL TIME SWITCH INSTALLATION AND OPERATING INSTRUCTIONS READ INSTRUCTIONS CAREFULLY BEFORE SETTING UNIT

TELEDYNE HASTINGS INSTRUMENTS

Instruction Manual. Series 3000 Model R-165A. Audio/Video IF/RF Relay Panel. CATV Switching and Control

7 Day Digital Programmer

MATE3 Owner s Manual Addendum

Automation Interface Requirements for J602 Basic I/O Interface of a DPC 4 Welding System

Automatic Transfer Switch Control PLC Operator s Manual

T775L Series 2000 Electronic Stand-Alone Staging Controller

TPHADA TRANSMITTER FOR HIGH PRESSURE WITH DIGITAL AUTO-ZERO & SPAN

Warner Photoscanner MCS-500 Series LED Photoelectric Control

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

1. General Information:

FIELD MOUNTED RATE TOTALISER MODEL 202D

Quick Operation Guide of LTN7700/7600 Series NVR

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

EZ Pro Instructions Zone Chart

DICKSON ES120/ES120A DICKSON. Electronic Signal Data Logger. Specifications. Applications, Features, & Getting Started. Instructions / Operating

LAUREL ELECTRONICS, INC.

Sentinel I24 Digital Input and Output Configuration

Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features

3214NXT. Service Manual. IMPORTANT: Fill in Pertinent Information on Page 3 for Future Reference

OUTDOOR IRRIGATION CONTROLLER LDC-6 LDC-11. User Manual

Quick Setup Guide for IntelliAg Model NTA

Manual. Analog (U/I) Sendix M3661 / M3681. Sendix M3661R. Sendix M5861. Absolute multiturn encoder. Order code: 8.M36X1.XXXX.XX12

E3X-DA-S. Digital Fiber Sensors. Perfection Transcended! A Wealth of Advanced Functions for Easy and Reliable Application

Chapter 2: Scanner Operations NOTE: Install the software cartridge Power the Scanner Select the software title Identify the vehicle

Exercise 4-2. Counting of Actuator Cycles EXERCISE OBJECTIVE & & &

SAPLING WIRED SYSTEM

Instruction Manual MODEL RSP SANITARY ELECTRONIC PRESSURE TRANSMITTER

TP7001 Range Electronic 7 Day Programmable Room Thermostat. Danfoss Heating. Installation Guide

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:

CALIBRATION OF SOLUTION SECONDARY CURRENT FOR 9180 controls with SC software PAGE 1 OF 5

- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request

Pressure Sensor. Ordering Information. Mini-Cube Pressure Sensor with Easy-to-Read LED Display

Arbor Scientific PO Box 2750 Ann Arbor, Michigan (800) Timer & Photogates 2.0 P Owners Manual

EZ Pro Jr. Installation and Programming Guide For EZ Pro TM Jr. models:

Operating Instructions

TEK-LCD 7801A. NEMA 4X Loop-Powered Feet and Inches Level Meter. ACCESSORIES. Technology Solutions

Sample BD Tech Concepts LLC

AES-402 Automatic Digital Audio Switcher/DA/Digital to Analog Converter

USER S GUIDE. 1 Description PROGRAMMABLE 3-RELAY LOGIC MODULE

SCALE & WEIGHT DISPLAYS

CLOCKAUDIO. MR88 Automatic Microphone Mixer. Version 4.2

Type MG-6 Auxiliary Relay Class 1E

Digital Flow Switch for Large Flow

263 Series LED Bargraph Indicator and Controllers

EDL8 Race Dash Manual Engine Management Systems

Provides an activation of Relay 1 triggered by Input 1. The function also provides an option for reverse-logic on the activation of Input 1.

BMW12N-H NTV-KIT791. Kit Contents. BMW12N-H Interface. Interface Power Harness

E3X-DA-S. Digital Fiber Sensors. Perfection Transcended! A Wealth of Advanced Functions for Easy and Reliable Application

Veeder-Root brand Series C628 Dual Preset Counter (C628-8XXX) Technical Manual

INSTRUCTION MANUAL V Barometric Pressure Sensor. May Copyright 2007 Campbell Scientific (Canada)Corp.

SPECIFICATION NO NOTE

Westerstrand T/T- display

MODEL OTM-4870 FREQUENCY AGILE 870MHz F.C.C. COMPATIBLE TELEVISION MODULATOR

innocon 6800D Online Luminescent Dissolved Oxygen Analyzer Opera ng Instruc on Dissolved Oxygen NORMAL REL 1 2 WASH 28.1 C jens WALL MOUNTING

Installation and Setting up Instructions for the 990 Signal Conditioning Instrument

PIXEL TOUCH PCB KEEP THIS MANUAL FOR FUTURE NEEDS

Transcription:

Digital Differential Pressure Gauge Switch 0.1 : 0.5 BAR USER GUIDE

Table of Contents GETTING STARTED DESCRIPTION Display Mechanical Electrical Mounting Programmable Settings Default Factory Settings PARTS IDENTIFICATION DISPLAY Low Power Display PROGRAMMING GENERAL-USING THE ARROW BUTTONS FLOW CHART FOR SETTINGS MANUAL OPERATION Manual Operation ON time SELECTING UNITS OF MEASURE TIME INTERVAL BETWEEN MEASUREMENTS CONTACT CLOSING TIME Contact Closed Time=A TIME INTERVAL BETWEEN CONTACT CLOSURE ZERO CALIBRATION SET CONTACT AND SERVICE INFORMATION GUARANTEE CONTACT INFORMATION 1 1 1 1 2 2 2 2 3 4 4 5 5 6 7 7 8 9 10 11 12 13 14 14 15

Electrical Mounting Power supply 9-24 VDC or 12-24 VAC Low power indication: LO P on display Dry contact (N.O.) 0.5 A at 24 VAC Internal memory retains settings when power is not supplied. 2 ft / 60 cm. 4 wire cable Red (+) and Black (-) to power supply Green and White to N.O. contacts Pressure ports 1/8 BSP / NPT male H pressure port marked on housing Important: Connect High pressure before Low pressure Disconnect Low pressure before High pressure. Programmable Settings Manual operation PSI or BAR display Time interval between pressure measurements Contact closed time Time interval between contact closure Zero calibration 2

Parts Identification Back view Electric cable Mounting screws Pipe Fittings Cover Display Setting Buttons Front view 3

Display Differential Pressure Differential Pressure Trigger setting Displays PSI 0.0 : 0.5 Displays BAR Relay On Manual Operation Left Button Decreases Values Right Button Increases Values Low Power Display LO P 4

Programming General - Using the Arrow Buttons To enter settings press and hold both buttons simultaneously. Use the left button for decreasing settings, selecting BAR measurements, and for turning off the device in the Manual mode. Use the right button for increasing settings, selecting PSI measurements, and for turning on the device in the Manual mode. After making an adjustment, holding the two buttons at the same time for 2 seconds, sets the adjustment and returns the display to the auto display. If the buttons are not held down for the full 2 seconds, until the auto display appears, no changes are made to the previous settings. When making an adjustment, if the buttons are not pressed for 30 seconds, the auto display appears and no changes are made to the previous settings. 5

Flow Chart for Settings Hold down both buttons to enter mode: Mode Auto Display 2 Seconds 4 Seconds 6 Seconds 8 Seconds Manual Operation Selecting Units Time Interval between measurements Contact closed time 2 Secs. 2 Secs. 2 Secs. 2 Secs. After making an adjustment hold down both buttons simultaneously for two seconds to set it and return to the auto display. 10 Seconds Time Interval between contact closure 2 Secs. 12 Seconds Zero calibration 2 Secs. 6

Manual Operation 1. Press both buttons for 2 seconds until the letter M flashes and the word ON appears. 2. Select ON or OFF. The left button selects OFF. The right button selects ON. 3. Hold the two buttons simultaneously for 2 seconds to set the selection. If you selected manual ON, M and ON will appear on the display. If you selected manual OFF only the M appears in the bottom row of the display. 0.0 : 0.5 On Manual OFF Manual ON Manual Operation ON time If you selected A (t=a) as the contact closed time setting, the contacts will close and remain closed until the third pressure differential pressure measurements takes place, then will open or close according to the pressure differential. 7

If you selected contact closed time t as a specific time in seconds, for example 10 seconds, then the contacts will close for 10 seconds. Selecting Units of Measure 1. Press the two buttons simultaneously for 4 seconds until PSI or BAR flashes. 0.0 : 7 0.0 : 0.5 Flashes Setting readings in PSI Flashes Setting readings in BAR 2. Press to switch from PSI to BAR. 3. Press to switch from BAR to PSI. 4. Set the selection by pressing on the two buttons simultaneously for 2 seconds. 8

Time Interval between Measurements The device checks pressure differential every few seconds. This interval may be set by the user. The longer the interval is between measurements, the lower the power consumption and the greater the battery life. The time interval may be set for any value from 0.5 to 99 seconds (0.5 appears as A). Press the two buttons simultaneously for 6 seconds, until the following display appears: 5 : 1 0 Flashes 1. Using the buttons, add or subtract time until you reach the desired time interval selection. In this example, 10 seconds has been selected. 2. Set by holding the two buttons down simultaneously for 2 seconds, until the dispaly returns tothe basic screen. 9

Time Interval between Contact Closure 1. This section explains the possibility operating the contact closure according to an internal timer; in addition to being operated by pressure differential. If In=A this section is not active. If In value is between 1-24 hours the maximum time between two cycles will be the In value. Example: In=3 if the pressure differential will not cause contact closure, then the contact will be closing every 3 hours for t time (page 10). 2. Press the two buttons simultaneously for 10 seconds until the following display appears: In A In 3 Flashes Flashes 3. Use the buttons to adjust the time or to select A. 4. Press the two buttons simultaneously for 2 seconds until the basic display appears, to set the selection. 12

Zero Calibration Set The pressure sensor should read zero when the pressure differential is zero. To check the calibration, remove the two pipe fittings from H and L. The pressure reading when the fittings are open to the atmosphere and there is no pressure differential between them should be 0. If not, set the reading to 0 as follows: 1. Press the two buttons at the same time and hold for 10 seconds until the following display appears: Flashes 0.1 : 0.5 BAR The pressure differential reading (here 0.1 BAR) flashes. 2. Press the two buttons at the same time for 2 seconds until the auto display appears and will now show 0.0. 13

Contact and Service Information 14

Contact Information FACTORY AND HEAD OFFICE Baccara Automation Control Kvutzat Geva 18915, Israel Tel: 972 4 6535960 Fax: 972 4 6531445 E-mail: sales@baccara.co.il Web Site: www.baccara.co il 07/07 BACCARA 42571501 15