Service and Technical Support PLEASE CONTACT YOUR NEAREST DISTRIBUTOR If unknown then fax: 44 (0)

Similar documents
Quick Setup Guide for IntelliAg Model NTA

Quick Setup Guide for IntelliAg Model CTA

Outback STX. User Guide Supplement. Parts List. STX Terminal Overview

DPM 942-FPSI 4-20mA Loop Meter with Programmable Backlighting

ED3. Digital Encoder Display Page 1 of 13. Description. Mechanical Drawing. Features

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV

Marks and Grades Project

Dimming actuators GDA-4K KNX GDA-8K KNX

Training Note TR-06RD. Schedules. Schedule types

800 Displaying Series Flowmeter

Model VF110-E Touch Screen Control Panel Users Manual

Sample BD Tech Concepts LLC

multi-function meters

OMEGA SERIES COUNTING SCALE

Model IQ4-PC User Manual Revision Date:

THE ASTRO LINE SERIES GEMINI 5200 INSTRUCTION MANUAL

Application Note 11 - Totalization

Figure 1: Standard 906 Sensor and Pulser Disc. Figure 2: Standard 906 Sensor and Pulser Wrap

ACT 10 Digital Keypad Operating & Installation Instructions This manual is found at

User Manual CC DC 24 V 5A. Universal Control Unit UC-1-E. General Information SET. Universal Control Unit UC-1 Of Central Lubrication PAUSE CONTACT

Dimming actuators of the FIX series DM 4-2 T, DM 8-2 T

IT-100 INSTRUCTION MANUAL

Installation & Operation Manual. BEC PM1 Controller Time/Flow/Volume Controller. Water Control Solutions

OPERATION MANUAL MODEL DF3000 DIGITAL WEIGHT INDICATOR REVISION A-1

American DJ. Show Designer. Software Revision 2.08

FRQM-2 Frequency Counter & RF Multimeter

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

Blown Film Extrusion. Line Control. 5 Layers CD Series IBC Temperature USER MANUAL

USER MANUAL Model: A5

Magnetic Rower. Manual Jetstream JMR-5000

SMART II. GRAVIMETRIC CONTROL FOR Gravibelt & Plasticolor USER MANUAL

THE ASTRO LINE SERIES GEMINI 4000 INSTRUCTION MANUAL

FIELD MOUNTED RATE TOTALISER MODEL 202D

OPERATION MANUAL OF MULTIHEAD WEIGHER

OWL micro+ WIRELESS ELECTRICITY MONITOR

Operating Instructions

BLOCK OCCUPANCY DETECTOR

EDL8 Race Dash Manual Engine Management Systems

HD-CM HORIZON DIGITAL CABLE METER

Quick Start Function Summary Instructions for ASHCROFT GC52 Differential Pressure Transmitter Version 6.03 Rev. B

Dohse Aquaristik GmbH & Co. KG

with the Field-IQ Crop Input Control System

ST9100C User Guide. Features

CS-200 SOLAR PORTABLE TRAFFIC SIGNAL SYSTEM FIELD MANUAL. 134 Ogilvie Avenue, Echuca 3564 (03)

SCALE & WEIGHT DISPLAYS

SINGLE ZONE CLIMATE ZONING SYSTEM. Technical Manual. Polyaire Pty Ltd

Luminaire installation box Surface-mounted box Ceiling installation box

COMPANY. MX 9000 Process Monitor. Installation, Operating & Maintenance Manual AW-Lake Company. All rights reserved. Doc ID:MXMAN082416

Show Designer 3. Software Revision 1.15

Transmitter Interface Program

Location. Electrical. Loads. 2-wire mains-rated, 0.5 mm² to 1.5 mm² Max. length: 300 m (with 1.5 mm² cable). Example: Belden 8471.

This document is a reference document that shows the menus in the 5500sc, 9610sc and 9611sc analyzers. There are 3 top-level menus:

Trimble CFX-750 Display with the Field-IQ Crop Input Control System

Pin setup: 1 (EXC+) 2 (EXC-) 3 (SIG+) 4 (SIG-) Pin setup: 2 (TXD) 3 (RXD) 5 (GND) others (NC)

SMART. GRAVIMETRIC CONTROL FOR BeltColor & GraviColor USER MANUAL. Manual Number: ST105 June, 2011

SPA MICROPROCESSOR SPEEDOMETER INSTALLATION AND OPERATING MANUAL PAGE 2...INSTRUMENT FEATURES PAGE 3...OPERATING INSTRUCTIONS PAGE 3...

Sample BD Tech Concepts LLC

THE FROG SERIES OPERATING MANUAL

IQORX30 / IQORX31. Single Mode Fiber Optic Receivers for 3G/HD/SD-SDI Signals

VLC-3 USER'S MANUAL. Light Program Controller. M rev. 04 K rev. 00 & ( ( 5, 352*5$0 1 : $ 2 ' 6(77,1*6 )81&7,216

C-net WIND. User s Guide

ORM0022 EHPC210 Universal Controller Operation Manual Revision 1. EHPC210 Universal Controller. Operation Manual

Standard signal metering in wall-mounting case

Weighing Scale. 10key&12key User manual

Part No. ENC-LAB01 Users Manual Introduction EncoderLAB

Mounts Machinery Field IQ Manual for CFX/FM-750 Display (ver 2.0)

Revision 1.2d

Manual. Simrad IS80 Heading Repeater HR80. English

A summary of all menu lines available in self-diagnostic mode is shown below.

SCENEMASTER 3F QUICK OPERATION

Registers type ILR7XX and ILR7XXT

Operating instructions Capacitive level sensor KNQ

USER & ENGINEER INSTRUCTION MANUAL

Troubleshooting. 1. Symptom: Status indicator (Red LED) on SSR is constant on. 2. Symptom: Output indicator (Yellow LED) on SSR is flashing.

SMART II. GRAVIMETRIC CONTROL FOR BeltColor & GraviColor USER MANUAL. Manual Number: SM II 102 December 2017

REVISIONS LTR DESCRIPTION DATE APPROVED - Initial Release 11/5/07 MDB A ECR /9/08 MDB

Operation/Users Manual

Operation Guide 5554

EXA PH200/400 and EXA PH202/402 Troubleshooting and Error Code Guide

MICROMASTER Encoder Module

12months. on-site warranty. DZE ELECTRONIC PRESSURE SWITCH for detection of overload per EN 81 2 featuring two adjustable switching points

E3C-LDA. Phone: Fax: Web: - Operating Procedures: Photoelectric Sensors

Ambient NOx monitor APNA-370 Operation Manual CODE:GZ D

Single Axis Position Controller

The UK sequence is shown below. The duration of each phase can be easily adjusted during the programming to suit.

Tube Rotator. User Guide. Version 1.2

TABLE OF CONTENTS. Instructions:

User Guide UD51. Second encoder small option module for Unidrive. Part Number: Issue Number: 5.

Pre-processing of revolution speed data in ArtemiS SUITE 1

BER MEASUREMENT IN THE NOISY CHANNEL

RAMMER INSTRUCTION MANUAL FITTING & OPERATING INSTRUCTIONS NEL PROGRAMMER. NSTAR Si MODELS

BLUNIK II ACCESSORIES SPORT DRIVE SPORT CALCULATOR... 49

Operations. BCU Operator Display BMTW-SVU02C-EN

IEFIS G3 Inputs, outputs and Alarms

Aspect 2 Circuit Digital Scene Control

Smart-Encoder : Optical Incremental

Liquid Mix Plug-in. User Guide FA

RWL11X2 GREENHOUSE CONTROLLER. Operation Manual

Main Display (Red) Displays the incident light level or the function name.

LEVEL CROSSING MODULE FOR LED SIGNALS LCS2

Transcription:

Electro-Magnetic Compatibility (EMC) This product complies with Council Directive 2004/108/EC when installed and used in accordance with the relevant instructions. Service and Technical Support PLEASE CONTACT YOUR NEAREST DISTRIBUTOR If unknown then fax: 44 (0) 1453 733322 Copyright RDS Technology Ltd 2005 Document number S/DC/500-10-505 : Issue 1 : 7/2/05 \UK505-1.DOC User Guide Athene 200 Fertiliser Spreader Monitor/ Variable Rate Controller Operation Software Reference WZ814-000 rev.5 1

Contents 1 Overview 4 1.1 System components... 4 1.2 The Head Unit and work measurement functions... 5 1.3 Switch Functions - Summary... 6 1.4 Instrument On-Off / Work Status Indication... 7 1.5 Channel Selection... 7 1.6 Starting and Stopping the Spreader... 7 2 Rate Control 8 2.1 Under-application (excessive speed)... 8 2.2 Setting the Target Base Rate... 8 2.3 Spot Application - Nudging the Target Rate... 9 3 Product Calibration 10 3.1 Calibration Procedure...10 3.2 FAQ s about Product Calibration...12 3.3 Correcting the Calibration Factor...13 3.3.1 Adjusting the "T" Factor...13 4 Other Work Measurement Functions 14 4.1 Forward Speed...14 4.1.1 Low Speed Alarm...14 4.1.2 High Speed Alarm (Under-application)...14 4.2 Area...14 4.2.1 Select Area Total 1 or Area Total 2 display...15 4.2.2 Reset Area Total 1 or Area Total 2 display...15 4.3 Work Rate...16 4.4 Spinner Speed...16 4.4.1 Spinner Underspeed Alarm...16 4.5 Hopper Contents- Display options...17 4.5.1 Low Level Alarm (using Hopper Level Sensor)...17 4.5.2 Weight display (Quantity left in hopper/ Quantity dispensed)... 17 4.6 The Quantity remaining in Hopper display...18 4.6.1 Resetting the Hopper Maximum Quantity figure...18 4.6.2 Set Alarm Quantity...18 4.6.3 Adjusting the Hopper Maximum quantity figure...19 2

4.7 Quantity Dispensed display... 20 4.7.1 Resetting the Quantity Dispensed display to Zero... 20 3

1 Overview 1.1 System components The instrument provides variable rate control of a twin shutter fertiliser spreader, by controlling two linear actuators to operate the traps. Here are the components of the control system. Spreader Switchbox Tractor Head Unit Power Supply Junction Box Forward Speed Sensor Spreader Junction Box Actuator - Left Trap Actuator - Right Trap Spinner RPM Sensor Hopper Level Sensor 4

This manual explains the everyday use of the Athene 200 Monitor/Controller to the operator, including regular calibration e.g. for spreading different products. Other calibration settings are explained in the calibration manual (ref. RDS Pt No. S/DC/500-10-455). 1.2 The Head Unit and work measurement functions The head unit is ruggedly designed for maximum reliability in harsh environments, and is rated to IP67 (effectively waterproof). The instrument has a 4-digit back-lit LCD display with 6 display channels for different work measurement functions. In the normal operating mode the following functions are displayed, Forward Speed (km /hr) Area Worked* (hectares) Work Rate (hectares /hr) Application Rate (kg/ha or tonnes/ha) or RPM depending on the application Spinner RPM Hopper Contents (kg or tonnes) * There are two memory registers to record area worked. The area is accumulated to whichever total is selected on the display Total 1 or Total 2. The head unit is switched on and off by the switch on the back the instrument. Area totals (and all calibration data) are automatically stored in memory when the instrument is powered off. 5

1.3 Switch Functions - Summary Target Rate Indicators Channel / Work Status Indicators Decrease Rate (% step) Increase Rate (% step) SELECT AREA TOTAL Select the channel then press to switch between Area Total 1 and 2. This button is also used to select the calibration function for the currently selected channel (see calibration manual for further information). Ch.1 SELECT CHANNEL Forward Speed AREA RESET With tot.1 or tot.2 selected on channel 2, HOLD for ten beeps to reset the selected area register to zero. This button is also used to confirm the entry after setting a new target rate using the 'RATE+' and 'RATE-' buttons. Ch.2 Area Total 1 or 2 Ch.3 Ch.4 Ch.5 Ch.6 Work Rate Application Rate Spinner RPM Hopper Contents 6

1.4 Instrument On-Off / Work Status Indication The power on-off switch is located at the rear of the instrument. The indicator indicates the channel to which the figure on the display relates. It also shows the working status of the spreader. The cursor flashes when the spreader is out of work (e.g. on the headland), and the area accumulation stops. The cursor is on continuously when the spreader is in work, and area accumulation takes place. 1.5 Channel Selection Simply press the button to cycle through the work measurement display functions. The instrument will always default to the application rate display 10 seconds after selecting any other channel (the exception to this is when there is an alarm condition). 1.6 Starting and Stopping the Spreader The spreader is started and stopped via the separate switchbox, not from the head unit. Spreader - Master On/Off Switch Left trap - Open/Close Right trap - Open/Close NOTE: If either trap is closed for half-width spreading, area automatically accumulates at half-rate on the instrument. 7

2 Rate Control NOTE: In normal operation, i.e. in work and in the absence of any alarm conditions, the instrument will display on this channel the calculated application rate (kg/ha). When out of work (and stationary) the target rate is displayed. A target base rate is programmed by the operator. For spot application, this base rate can be adjusted up or down in % steps as required while the system is in work. The instrument will control the actual application rate to meet the target rate irrespective of the forward speed. Note however, that the forward speed range over which the system can meet the target rate will depend on the rate set. If the forward speed is too high or too low, the instrument will alert the operator with an audible alarm. 2.1 Under-application (excessive speed) If your forward speed exceeds the maximum beyond which the target application rate cannot be achieved (i.e. the actuator(s) have reached their maximum extension), then the instrument defaults to a flashing forward speed display and beeps continuously. You must reduce your forward speed sufficiently for the target rate to be maintained, at which point the instrument will stop beeping and return to the application rate display. 2.2 Setting the Target Base Rate The target base rate can only be set with the spreader out of work and stationary. 1. Select the channel and the base rate is displayed. 2. Then press and hold either the or buttons to adjust the rate up or down. 8

NOTE: The display will briefly show the %step size by which the target rate can be nudged when in work, before the target rate begins to change. The longer you hold either button the more rapidly the target rate will change. To make smaller adjustments, release the button and then make single presses to adjust the rate in 1kg increments. 3. Press the button to confirm the new target rate setting. 2.3 Spot Application - Nudging the Target Rate You can adjust the application rate up to 50% above or below the target rate whilst in work. Press the or button to nudge the rate up or down by a preprogrammed % (5% by default). NOTE: Refer to the calibration manual to set the % step size. The bar on the left side of the display indicates when you are above or below the target rate. When nudged above or below the target rate the application rate display will flash, alternating between the new application rate and the % nudge e.g, if a target rate of 500 kg/ha is nudged minus 5%, the display will then alternate between 475 (kg/ha) and -5. -5% below target At target +5% above target Press to return to the target rate. 9

3 Product Calibration To ensure that the system applies the correct quantity of fertiliser, requires the operator to perform a bucket test for each fertiliser type. The instrument has a bucket test mode for this purpose. The bucket test can only be performed with the spreader out of work (the indicator must be flashing) and the vehicle stationary. 3.1 Calibration Procedure 1. Remove the left disc and prepare the bucket to collect the dispensed fertiliser. 2. Place the fertiliser to be tested in the hopper. 3. Enter the bucket test mode ('CAL.3' mode) by pressing the switch whilst turning the power on. The instrument displays the simulated forward speed (default = 8 km/hr) that will be used during the test. If required, this can be modified to represent the typical operating speed using the switch. 4. Press the switch to move to the next channel to set a simulated area. This is the area over which the product calibration test will be simulated. There are 3 options to choose from depending on the intended application rate and bucket size Intended application rate (kg/ha) Display Simulated Area (ha) 0-100 'baja' 0.4 100-300 'NOR' 0.13 300-800 'ALtA' 0.05 10 5. Press the switch to select the desired option and move to the next channel to set the target application rate. 6. Enter the target rate using the and switches. Press to confirm and select the next channel. 7. The display will show disc indicating to the operator to run the PTO at the normal speed to ensure the agitation is working correctly above the metering outlet. Once the spinner speed is detected the instrument will flash 0000.

NOTE: If you are performing calibration tests for an extended period, there is a possibility that fertiliser can become compacted and overheat above the closed right hand trap, due to there being no material flow. Therefore you are advised that during extended bucket testing, to ensure that the right hand side remains empty of fertiliser. 8. Open the left trap using the switch box and the actuator will extend to the required position to satisfy the rate and speed previously set, based on the current T factor. The display will show run. It will remain open until the programmed area has been simulated, where upon it will close automatically irrespective of the switch box. The display will then show stop. 9. Stop the PTO. When the instrument registers that the shaft speed is zero the instrument will then display the message trap until the left actuator switch is returned to the 'off' position. No switches will function until this is done after which the display will flash the theoretical expected weight. 10. Weigh the contents of the bucket. 11. Adjust the weight displayed using the and switches to match the amount weighed from the bucket. Press to confirm and select the next channel. 12. The instrument displays the newly calculated T factor and you should record this in the manual for future use. This value will overwrite the factor in programming mode 1, channel 4. If the newly calculated value is outside the limits 0.800-1.200, then the display will show Err1, indicating that the test must be repeated. 13. Press to repeat the test from step 3, or turn the instrument off and on again to return to normal operating mode. 14. Re-fit the left disc ready to go spreading. 11

3.2 FAQ s about Product Calibration Possible cause Remedy There is a small discrepancy in the amount applied. The tank surfaces have surface As the surfaces become polished corrosion, which reduces material by material flow during normal use, flow. you may need to adjust the "T" factor (3.3). The flow characteristics of the fertiliser are different to that used for calibration. Normal variations such as field conditions, humidity, nature of product etc. The fertiliser may have absorbed more moisture than the material used in the bucket test, so you may need to adjust the "T" factor (3.3). Adjust the "T" factor (3.3). There is a big discrepancy in the amount applied. The programmed spread width is From normal operating mode, incorrect. select the channel, then press and hold to view width setting. The forward speed is incorrect due to incorrect calibration. No forward speed signal. The instrument beeps continuously Forward speed too high. Perform an 'AutoCal' (refer to calibration manual). Check wiring connection of forward speed sensor. Check that the magnet passes within 10-15mm of the sensor. The beeping indicates that the control parameters have been exceeded, and so the application rate set cannot be met. As a result the actual quantity dispensed will be less than it should be. Simply reduce your speed. 12

3.3 Correcting the Calibration Factor If after spreading in the field, you find a consistent discrepancy between the instrument weight reading and the actual weight dispensed, then calculate a corrected "T" factor using a simple formula and re-programme it. A corrected factor can be determined by a simple calculation using the actual weight and the displayed weight as follows : Corrected factor = Programmed factor x Actual weight Displayed weight For example: The existing factor is 0.904. The displayed weight was 780 kg but the actual weight dispensed was 1000kg. The "T" factor needs to be set as 0.904 x (1000/780) = 1.158 Therefore, if the weight displayed on the instrument is more than the actual weight dispensed, the "T" factor must be decreased, and if the weight displayed on the instrument is less than the actual weight dispensed, the "T" factor must be increased. 3.3.1 Adjusting the "T" Factor 1. While in the normal operating mode, select the rate channel ( ). 2. Press and hold the switch for 3 seconds. The existing "T" factor then flashes on the display. 3. Adjust the figure up or down using the or switches. 4. Press the button again to return to the normal operating mode. 13

4 Other Work Measurement Functions 4.1 Forward Speed The forward speed is displayed in km/hr. 4.1.1 Low Speed Alarm If the forward speed drops below 0.5 km/hr while the spreader is operating (i.e. material is flowing out of the trap(s)), the instrument defaults to a flashing forward speed display and the instrument beeps 5 times every 30 seconds. The instrument will return to the application rate display when forward speed increases above 0.5 km/hr. 4.1.2 High Speed Alarm (Under-application) This alarm is activated when, as a result of too high a forward speed, the actuator is required to extend further than its maximum extension, and consequently the target rate cannot be met. The instrument defaults to a flashing forward speed display and beeps continuously. The instrument will return to the application rate display only when forward speed is reduced sufficiently for the target rate to be met. 4.2 Area The area (in hectares) is derived from the forward speed (or the simulated speed for the calibration test) and the programmed implement width. Area will only accumulate when the spreader is switched on and either one or both traps are open. If one trap is closed, then area accumulates at half rate. There are 2 memory registers - 'Total 1' and 'Total 2' and area accumulates to both of them. These totals can be independently reset to zero. 14

4.2.1 Select Area Total 1 or Area Total 2 display 1. Select the channel. 2. Press to cycle between the two area totals. The display will then show tot.1 or tot.2 before displaying the area accumulated since that total was last reset Figure 4: Select Area Total 4.2.2 Reset Area Total 1 or Area Total 2 display 1. Select the channel. 2. Press to cycle between the two area totals. 3. Hold for 5 seconds to zero that total. HOLD 5 SEC Figure 5: Reset Total 1 / Total 2 NOTE: A grand total area (non-resettable) can be viewed in the calibration mode (refer to the Calibration manual). 15

4.3 Work Rate The work rate is displayed in ha/hr. The work rate is derived from the working width set and the forward speed. It is based on the currently selected area register 'Total 1' or 'Total 2' (therefore there are 2 work rate registers). The work rate is updated each time the system registers 'out of work' (i.e. the spreader is switched off). 4.4 Spinner Speed NOTE: This channel displays the r.p.m. of the spinner. Within the normal operating range, the spinner speed is displayed to the nearest 10rpm. This channel cannot be selected if the spinner sensor cal factor is set to zero in calibration mode 2 (refer to the calibration manual). 4.4.1 Spinner Underspeed Alarm If the spinner speed drops below a user-programmed threshold (default = 400rpm), instrument will default to the spinner rpm display and will beep 5 times every 30 seconds. You can temporarily ignore the alarm by selecting another channel. The instrument will return to the application rate display when the spinner speed is restored above the threshold. If the spinner speed registers zero, the traps are automatically closed and the instrument display flashes 'disc'. Starting the spinner will cancel the display message and enable the traps to be opened. The low speed alarm threshold is set in calibration mode 2 (see calibration manual). 16

4.5 Hopper Contents- Display options This channel gives either a simple low level alarm or displays the hopper contents, depending on how the system is configured. 4.5.1 Low Level Alarm (using Hopper Level Sensor) NOTE: If the hopper is fitted with a level sensor, when you select this channel it will briefly display 1 to indicate that the alarm is enabled, and then display nothing. This is the default setting. If 0 is displayed then the alarm is disabled. When the hopper contents fall below the sensor, the display will default to this channel and flash Alar, and the instrument will beep 5 times every 30 seconds. You can temporarily ignore the alarm by selecting another channel. The hopper level alarm does not function when the forward speed is less than 2km/hr. 4.5.2 Weight display (Quantity left in hopper/ Quantity dispensed) The instrument must be set for Volumetric hopper contents in the calibration mode (if necessary, refer to the calibration manual). Based on the application rate, the system calculates the theoretical quantity in the hopper, displaying either the total weight dispensed or the quantity remaining in the hopper, depending on how the instrument is configured in the calibration mode. If kg units are selected, the units are kgs up to 9999 thereafter the decimal point indicating the readout is in tonnes (to the nearest 10kg) e.g. 10.10 tonnes. 17

4.6 The Quantity remaining in Hopper display If the Hopper Maximum Quantity is set to a value above zero in the calibration mode (refer to the Calibration Manual to set this), the display will count down from the maximum figure, showing the quantity of product remaining in the hopper. When the calculated weight reaches the preprogrammed hopper alarm-weight, the instrument will sound 5 beeps every 30 seconds. 4.6.1 Resetting the Hopper Maximum Quantity figure Select the channel, then press and hold the button. The instrument will give 10 beeps then resets to the default figure. The factory default setting is 2000kg. 4.6.2 Set Alarm Quantity 1. Select the channel, then press and hold the button for 3 seconds The current alarm quantity appears (fig 8a). The factory default setting is 250kg (0250). 2. Continue holding the button. 3. PRESS and RELEASE the button to select the digit or decimal point to change, or... Press and hold Figure 8a: View Alarm quantity 4. HOLD the button to change the digit or move the decimal point. Remember, setting a decimal point sets the units as tonnes. If no decimal point is set, the units are in kgs. 5. Release the button to return to the normal operating mode. HOLD 3 4 Figure 8b: Set Alarm Quantity 18

4.6.3 Adjusting the Hopper Maximum quantity figure The meaningfulness of the display is reliant on the Hopper Maximum Quantity being correctly programmed for the actual quantity of product in the hopper at the start. You may well want to adjust the default figure (e.g. for a part-loaded hopper) 1. Switch the instrument off. Press and hold the and switch the instrument on. 2. Press to select the channel. The maximum quantity then appears with the first digit flashing (fig.9a). You can now release the button. 3. PRESS and RELEASE the button to select the digit or decimal point to change, or... 4. HOLD the button to change the digit or move the decimal point. Remember, setting a decimal point sets the units as tonnes. If no decimal point is set, the units are in kgs. 5. Switch the instrument off and then back on again to return to the normal operating mode. When the spreader is put into work, the display will then continue counting down from the figure that has been entered above. 1.Hold for 10 seconds Figure 9a: View Hopper Maximum Quantity 2 Switch on 3 4 Figure 9b: Set Hopper Maximum Quantity 19

4.7 Quantity Dispensed display If the Hopper Maximum Quantity is set to zero in the calibration mode (see 4.6.3), the alarm function is disabled and the display will count up from zero, indicating the quantity of product dispensed. 4.7.1 Resetting the Quantity Dispensed display to Zero You can reset to zero, e.g. if logging individual hopper loads, field totals, daily totals etc. Please note however, that aside from this channel total there is no independent grand total that stays in the instrument s memory. Select the channel, then press and hold the button. The instrument will give 10 beeps then reset to zero. 20

Product Application rate (kg/ha) "T" Factor 21

Product Application rate (kg/ha) "T" Factor 22

Issue 1 : 7/2/05 Original issue (based on S/DC/500-10-454) 23