Automatic Transfer Switch Control PLC Operator s Manual

Similar documents
Transfer Switch. OTECA (Spec A) OTECB (Spec A) OTECC (Spec A) OTECD (Spec A) Amperes. English Original Instructions (Issue 5)

USER MANUAL. 22" Class Slim HD Widescreen Monitor L215DS

USER MANUAL. 27 Full HD Widescreen LED Monitor L27ADS

SINGLE ZONE CLIMATE ZONING SYSTEM. Technical Manual. Polyaire Pty Ltd

USER MANUAL Full HD Widescreen LED Monitor L215ADS

USER MANUAL Full HD Widescreen LED Monitor L215IPS

USER MANUAL. 27 Full HD Widescreen LED Monitor L270E

Timer Modules. MEU11 24 Hour Module, MEU17 7 Day Module (Without Housing)

USER MANUAL Full HD Widescreen LED Monitor L236VA

XTM72 Exerciser Timer Module

OPERATION AND MAINTENANCE

DCP100 Digital Control Programmer Specifications

4.0 Description. 2-channel operation D1 and D2 rated at 200 VA each. 1-channel operation D1 rated at 400 VA (see connection chap. 6.

HOME GUARD USER MANUAL

USER MANUAL. 27" 2K QHD LED Monitor L27HAS2K

Operating Instructions

USER MANUAL. 28" 4K Ultra HD Monitor L28TN4K

talento 800 Series 365-Day One, Two and Four Circuit Electronic Time Controls Functional Description

263 Series LED Bargraph Indicator and Controllers

B. The specified product shall be manufactured by a firm whose quality system is in compliance with the I.S./ISO 9001/EN 29001, QUALITY SYSTEM.

PLL1920M LED LCD Monitor

FN:4181NX_M1.DOC MC4181NX MASTER CLOCK MC4181NX

FN:4181M5.DOC MC4181N SERIES MASTER CLOCKS MC4181N

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

Electronic Timer Control Day Astronomic Electronic Control

Luminaire installation box Surface-mounted box Ceiling installation box

Dimming actuators GDA-4K KNX GDA-8K KNX

Label Applicator HERMA 400

EVF 300 series. Controllers for electric bread and pizza ovens, with touch-keys, in split version and which can be integrated into the unit.

Safety Precautions and Maintenance

ORM0022 EHPC210 Universal Controller Operation Manual Revision 1. EHPC210 Universal Controller. Operation Manual

MICROMASTER Encoder Module

Timer Modules. EL11 24 Hour Module EL17 7 Day Module. Installation & Operating Instructions

HS-509 VIBRATION TRIP MODULE

XTM72E & F Real-Time Clock Modules

Two (2) Channel 365 Day 24 Hr. Timer/Controllers

EA63-7D. Generator Automatic Voltage Regulator Operation Manual. Self Excited Automatic Voltage Regulator

16 Amp Electronic 24 Hour/7 Day Time Controller

ex 800 Series ematrix System

PLL2210MW LED Monitor

Installation & Operations Manual

Sprite TL Quick Start Guide

USER S Manual NGLT104WPD NGLT150WPD LCD TV / Monitor (IP67 Grade)

PRINCIPLES AND APPLICATIONS

Softswitch128TM. SwitchingSystem. Setup and Maintenance Guide

VLC-3 USER'S MANUAL. Light Program Controller. M rev. 04 K rev. 00 & ( ( 5, 352*5$0 1 : $ 2 ' 6(77,1*6 )81&7,216

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

User interface. Abbreviations / Meanings

Self Excited Automatic Voltage Regulator For Generator Compatible with Marathon SE350* Operation Manual

Solis Export Power Manager

Overview: Specifications: Installation Instructions:

CURRENT INJECTION RELAY TESTER CR-100. ( Code P60212 (770081) ) INSTRUCTIONS MANUAL ( M / 05A ) (c) CIRCUTOR S.A.

User Manual. Innovative LCD Display Solutions AP-20 Series DP-20 Series OP-20 Series NAP-20 Series

Safety Light Curtains

Defrost Control Installation and Programming of Version 3.1 Cards

Description. Specifications and Ordering Information 1900/27 Vibration Monitor

Siteco Service Box User Manual 1/31

PL2410W LCD Monitor USER'S GUIDE.

BY-HPE11KTA. Operating Instructions. Coaxial - LAN Converter with PoE function. Indoor Use Only. Model No. Attached Installation Guide

T +31 (0) F

TABLE OF CONTENTS. Instructions:

Dimming actuators of the FIX series DM 4-2 T, DM 8-2 T

IP Roombox. Hotel Room Management

AHP-1200CPV Cold/Warm Plate Product Manual Volume 1.3

FD Trinitron Colour Television

User Manual CC DC 24 V 5A. Universal Control Unit UC-1-E. General Information SET. Universal Control Unit UC-1 Of Central Lubrication PAUSE CONTACT

Junior Max (JR Max ) Controller

28 & 32 & 40 & 55 & 65 & 84-INCH TFT-LCD 4K MONITOR

Smart-Encoder : Optical Incremental

SCALE & WEIGHT DISPLAYS

28 4K LED monitor. User Manual M284K

SPECIFICATION NO Model 207 Automatic GTAW Welding System

PLC Control Unit for a CSM-E Electrical Compact Clean Steam Generator

DIGITAL TIME SWITCH 7 DAY WITH INPUT DGU100A DGUM100A DGLC100A DGLC200A

Low-Cost, Single-CT, Automatic Power Factor Controller for Balanced Three-Phase Reactive Power Compensation User Manual

MSC+ Controller. Operation Manual

AF-300 E11 Adjustable Frequency Drive

Trusted 40 Channel 120 Vac Digital Input FTA

Transponder Reader TR22A01KNX TR22A11KNX. Product Handbook

Innovative Air Systems ABN When Calling For Support Quote:.doc

Sensopress LCD Special English

REGO Start&Go USER MANUAL

MODEL OTM-4870 FREQUENCY AGILE 870MHz F.C.C. COMPATIBLE TELEVISION MODULATOR

INSTALLATION & USER GUIDE

INSTRUCTIONAL MANUAL FOR LCD ZOOM MICROSCOPE

Assembly. Front view. LEDs. Parametrization interface. Power Bus

A6 OPERATING INSTRUCTIONS

SAL Series Wireless Clock (V1)

Westerstrand T/T- display

FX-2DA SPECIAL FUNCTION BLOCK USER'S GUIDE

COMFORT COMFORT CALL OWNER S MANUAL CALL SYSTEM P/N P BASE STATION & RF WIRELESS MODULE. Complete Control from TOTALINE

High performance circuit breakers

LED control gear Compact dimming. Uconverter LCAI 2x38 W 0500 K013 one4all ECO series. Ordering data

Trusted 40 Channel 120 Vac Digital Input FTA

PLL2710W LED LCD Monitor

Active UTP Transceiver Hub Installation Guide

4K LED MONITOR 430LED4K & 550LED4K INSTRUCTION MANUAL. Please read this manual thoroughly before use, and keep it handy for future reference.

Gamma instabus. Technical product information

AES-402 Automatic Digital Audio Switcher/DA/Digital to Analog Converter

INSTRUCTION & OPERATION MANUAL. MODEL MMW-05 (5kW) MUROMACHI MICROWAVE FIXATION SYSTEM

Transcription:

MTS Power Products MIAMI FL 33142 ATS-22AG Automatic Transfer Switch Control PLC Operator s Manual Dedicated Single Phase Transfer Switch

ATS-22AG Automatic Transfer Switch INTRODUCTION 1.1 Preliminary Comments and Safety Precautions The manual covers installation, operation and maintenance of the ATS-22AG Automatic Transfer Switch and Controller. This manual is for use by authorized and qualified personnel only. WARNING High voltages can kill. 1.2 Overview Transfer switches protect critical electrical loads against loss of power. A standby (emergency) generator backs up the normal grid power. The transfer switch connects either the NORMAL (Power Co. Grid) or the generator EMERGENCY to the LOAD. When power is lost the switch transfers the load to the generator. Eventually after the grid is restoration, the ATS connects the load back to the grid. 1.3 Product Overview Programmable exerciser with Load. Exerciser set for one time per week wih load. Emergency position contacts for Auto-Dialer Simple programming on-site Auto-saved settings (memory preserved throughout all power disconnects and resets). Front panel display provides source status and fail alarm indications. 1.4 Functions / Features The primary function of ATS-22AG controller is to monitor grid / normal street power and provide the necessary intelligence to operate the ATS switch 1.4.1 Operational Simplicity Installation, programming and use of the ATS-22AG controller is designed to be easy. The friendly front panel simplifies routine operation, programming and adjustments. The ATS-22AG is a programmable automatic transfer switch Controller. It s suitable for single phase systems only, and including all necessary monitoring and protections. The ATS-22AG features: Smart touch screen (touch sensor) design. Compact size with user-friendly LED display. All programming and operations are done from the front screen interface. Monitors grid and emergency for over and under voltage anomalies. Monitors grid and emergency for over and under frequency anomalies. 1

ATS-22AGAG Automatic Transfer Switch Line 1: Time Delay Emergency to Normal (TDEN) TDEN delays the transfer from the emergency back to the grid, permitting the stabilization of the grid before returning. Timing begins when the grid becomes available. Adjustable TDEN time range: 00 to 990 sec Line 2: Time Delay Normal to Emergency (TDNE) TDNE delays the transfer from normal to emergency to permit stabilization of the generator before the transfer is made. Timing begins when the generator becomes available. (sometimes called the warm-up timer) Adjustable TDEN time range: 0.0 to 250 sec O/V adjustment range : 110VAC to 300VAC O/V reset value: 10VAC (Not adjustable) U/V adjustment range: 80VAC to 240VAC U/V reset value: +10VAC (Not adjustable) Programmable exerciser It can be set to exercise one time per week at any day and time, with load. The length of the exercise is also set. (Refer programming lines 10, 11, 12, 13, 14 & 15) NOTICE COMMON ALARM provides AN auxiliary dry contact for use when the ATS is in Emergency position (Its ON only for 60 sec) Line 3: Time Delay Engine Start (TDES) This timer prevents nuisance start because of momentary electrical glitches. If power normalizes before the countdown ends, the controller skips the engine start and resets the timer. Adjustable TDES time range: 0 to 30 sec Line 4: Time Delay Engine Cool-down (TDEC) TDEC permits the generator to run unloaded after the ATS return to the grid. Timing begins when the ATS connects back to grid power (If you already have cool-down on the Generator Controler this time is also added to the ATS cool-down timer) Adjustable TDEC range: 0 to 999 sec Line 5: Time Delay Center OFF Position This timer temporally stops the switch in the center OFF position (completely cut off) before proceeding to normal. Useful is some computerizes system that need time in OFF to reset. Adjustable time delay range: 0 to 99 sec Lines 6, 7, 8, & 9: Over / Under Voltage and Loss of one wire sensing The controller monitors the voltage from grid and the generator. The client can program over & under voltage window. (Refer to program table line 6, 7, 8, & 9 2

ATS-22AGAG Automatic Transfer Switch 1: LED Test Touch & hold the OFF button, all LEDs light up. 2.3.1 Increase ( ) Button When programming the up ( ) button increases the displayed parameter by one unit. If held, the up ( ) button continues to scroll. 2.3.2 Decrease ( ) Button 2: OPERATION 2.1 Display Window The ATS-22AG controller has a 4-digit, 7-segment displayer to monitor all parameters, setting and messages. The screen displays: Voltage / frequency Current Time HH:MM (In OFF only) Sec. delay countdown Program setting parameters When programming touching the down ( ) button decreases by one unit. If held, the down ( ) button continues to scroll. 2.3.3 Auto Button In AUTO, the ATS-22AG runs in automatic mode lighting the corresponding LED to indicate the ATS is in AUTO. In AUTO controller automatically starts the generator, transfer and retransfers from grid to generator as commanded. 2.3.4 Test Button Touching the TEST button simulates a power failure and begins a testing sequence. for 20 min and then return to AUTO. If at any time the generator fails in TEST mode the ATS returns to AUTO if Normal power is available. 2.3.5 OFF Button 2.3 Operate Touch Buttons The front panel has 5 sensitive capacitive touch buttons. Touching the OFF turns the ATS-22AG OFF engaging a flashing red LED disabling all functions and the screen shows the Time of Day 3

ATS-22AG Automatic Transfer Switch 2.4 Panel LED Outputs Eight individual red and blue LEDs light bars perform or indicating each function. Emergency over voltage Information concerning the LEDs output Power available display normal / grid & emergency Emergency under voltage Emergency over frequency Normal / grid over voltage Emergency under frequency Normal / grid under voltage Normal / grid transfer failure Normal / grid over frequency Emergency transfer failure Normal / grid under frequency 4

ATS-22AG Automatic Transfer Switch SECTION 3: OPERATION 3.1 General The four functions of the ATS-22AG: In AUTO In OFF In TEST mode Programming The practical use of each operation under each category is explained in this section. It is assumed that prior sections are understood, and the operator has a basic understanding of the hardware. 3.2 IN AUTO The AUTO mode of the ATS-22AG controller provides automatic engine start, stop, and power transfer and retransfers from source to source as dictated by the values previously programmed. The ATS-22AG constantly monitors the condition of both the grid and/or generator providing the intelligence for the transfer operations. In AUTO the ATS can starts the generator, using a normally open dry remote start connection. Next to the remote is the connections for the Common Alarms which are activated only for 60 sec. when the ATS moves to the Emergency Position 3.3 IN OFF In OFF the ATS-22AG disables all the transfers and protection functions with all LED indicators OFF leaving the display screen showing only the time of day. The user can test the LEDs by touching the OFF button. Reset the clock once a year. The wrong time can affect the schedule exerciser. Without power, the controller can maintain the clock working for up to a week. However, when in programming, the OFF button allows you to move to the next program line and then change the values for that line using down ( ) and up ( ) buttons. 3.4 Manual TEST (TEST) Touching TEST simulate a loss of normal/grid power. Permitting the controller to start the engine and carry out a power transfer UNDER load for 20 min. After 20 Minutes the Control automatically return to AUTO. If at anytime the Generator stops when under TEST and NORMAL Power is available the ATS return to Normal. 3.5 Programming Instruction You program the ATS-22AG from the front faceplate. To start, set the controller to OFF and touch & hold the OFF button for 5 seconds (The screen flashes 3 times). The word Vr2.0 appears on the display for 2 seconds, showing the software version. You are ready to start the line-by-line programming sequence. Always touch the OFF key to move to the next line, to change the parameters, on each line use the up ( ) and down ( ) arrows. Repeatedly touching the up ( ) or down ( ) key, changes the displayed by one. To change faster, hold the buttons down. Remember to always touch the OFF button to move to the next line or until the End appears on the screen. Note: To end and exit at any time, hold the OFF key down for 4 seconds. If you make an error or need to return to factory settings, stay or reenter programming and then hold the AUTO keys down for 4 seconds, until the word Au.Po appears on the screen verifying that all programming lines are factory reset back like in the manual. (See line-by-line programming table for ATS-22AG factory settings). 5

3.7 To enter the Line by Line Programming Table Simply touch and hold the OFF button for 5 sec. and after the screen flashes 3 times remove finger To go from one line to the next touch OFF each time & change values by using the UP/Down Arrows. LINE DISCRIPTION VALUE FACTORY SETTING 1 TDEN Time Delay Emergency to Normal 00 to 999 sec 10sec 2 TDNE Time Delay Normal to Emergency 00 to 250 sec 10sec 3 TDES Time Delay Engine Start 00 to 30 sec 05sec 4 TDEC Time Delay Engine Cool-down 00 to 999 sec 00sec 5 Time Delay in the OFF Position 00 to 25 sec 02sec 6 Normal over voltage protection setting 11 to 30 ( 110V to 300V ) 27(270V) 7 Normal Under voltage protection setting 08 to 24 ( 80V to 240V ) 18 (180V) 8 Generator over voltage protection setting 11 to 30 ( 110V to 300V ) 27(270V) 9 Generator Under voltage protection setting 08 to 24 ( 80V to 240V ) 18 (180V) 10 Set today s day of the week Day 1 to 7 (Monday to Sunday) current 11 Set today s hour Hour 00 to 23 current 12 Set today s minutes 00 to 59 current 13 Set day of week to do the engine exercise 1 to 7 (Monday to Sunday) 6 14 Set the time to start the exercise 00 to 23 ( 24 Hr Clock ) 12 15 Exercising duration 00 to 99 Minutes ( 0 = Do not exercise) 00 16 Exercise with load or without load 00) Without load 01) With load 01 17 18 Install & Enable Remote Ethernet Module KCU-30. Restore Passwords to factory settings Monitor & Control-0000, Monitor only-9999 00) Disable 01) Enable 01 00) No 01) Yes 00 In case a KCU-30 is not installed Line 18 vanishes & is not used. Line 18 comes in handy if you forget your password for the KCU-30 when using remote monitoring software on your PC or Smart Phone. After a password reset remember to use a new password on your PC or Smart Phone App for your protection. To EXIT programming, press OFF for 5 sec.

ATS-22AG Automatic Transfer Switch 3.8 Specification Summary PARAMETER AC Voltage Measurement Range Frequency Measurement Range Remote Start Contact Normal ON Contact Emergency ON Contact Auxiliary Contact Output Operating Temperature Storage Temperature Operating Humidity SPECIFICATION 50 VAC to 300 VAC 50/60 HZ 40HZ to 75HZ 7A @ 250VAC Max 7A @ 250VAC Max 7A @ 250VAC Max 7A @ 250VAC Max -4F to 160F -4F to 160F Weight 0.55lbs 2% Maximum 90% relative humidity SECTION 4: INSTALLATION INSTRUCTIONS 4.1 General The ATS-22AG is made for front panel mounting. 4.2 Panel Cut-Out (All Dimensions in Inches) 4.45 6.6 7

ATS-22AG Automatic Transfer Switch 4.3 Unit Dimensions ( All Dimensions in MM. ) 4.4 Installation Reference Screw Silicon waterproof seal Panel Cut-out Fix bracket Screw Fix bracket A T S Metal door 8

ATS-22AG Automatic Transfer Switch SECTION 5 : TYPICAL WIRING AG Unit MAINS L1 L2 #NLS>>Normal Auxiliary Switch #ELS>>Genset Auxiliary Switch LOAD L1 L2 ATS-22AG Control Unit MCCB TYPE BTS L1 L2 GENSET 8

Normal Breaker ON LOAD L1 L2 Emergency Breaker OFF MAINS 240V L1 L2 L1 L2 GENSET 240V N 1 240v Sensing Feedback Feedback 240v Sensing ATS-22AG Using a ATS-22AG control on a Cutler Hammer Switch Drawing made with the Switch Connected to Normal Power

Update your old C.H. M... Break Board with a brand new MTS/ McPherson Motor Stop Board that is fully compatible with the original equipment. The big difference is quality and price. a.- Heavy Duty Printed Circuit Board with oversize connections. b.- Flywheel Diode Added to prevent back current flashing of shorting relay c.- Same Installation Procedure d.- Economical - +