DM CONTROL MODULES (VCS-R-DM-..)

Similar documents
EZCOM-1. PLC - to - AMS MESSAGE DISPLAY INTERFACE INSTALLATION AND OPERATING INSTRUCTIONS. Rev March, 2001

Sample BD Tech Concepts LLC

Sample BD Tech Concepts LLC

TRANSCENSION 6-CHANNEL DMX DIMMER PACK (order code: BOTE40) USER MANUAL

DLP200M 2 Relay Module for Heating and Cooling Plants

Safety Precautions and Maintenance

Luminaire installation box Surface-mounted box Ceiling installation box

Model DT-311J. And DT-311J-230V(AC) DIGITAL STROBOSCOPE INSTRUCTION MANUAL

VLC-3 USER'S MANUAL. Light Program Controller. M rev. 04 K rev. 00 & ( ( 5, 352*5$0 1 : $ 2 ' 6(77,1*6 )81&7,216

Digital Time Switch. Installation & Operating Instructions

Dimming actuators of the FIX series DM 4-2 T, DM 8-2 T

Fusion 120 Zoom. User Manual. Order code: EQLED068

Sensor module. Safety instructions. Function Correct use. Product characteristics. Structure of the device. Operation. Ref.No.

42 Freestanding Infrared Multi Touch Screen Kiosk User s Manual

Premium INSTALLATION AND USER GUIDE ENGLISH TAHOMA BOX. - INSTALLATION AND USER GUIDE. Rev A _01-16

DLP600M 6+1 Relay Module for Heating and Cooling Plants

7 Day Digital Time Switch

DMX Operator 192-channel lighting controller

NEA WIRING CENTRE NEA HT 230V /24 V

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

Operation Guide 6022 ENGLISH

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

7 Day Digital Light Switch with Optional Dusk Start

M150SP USER S AND INSTALLER S MANUAL. v2.0 REV. 03/2017

Commander 384. w w w. p r o l i g h t. c o. u k U S E R M A N U A L

ALO 030 MKII. 30 Watt DMX LED scanner. User manual

COLOR TFT LCD MONITOR WITH MULTI-TOUCH FUNCTION Manual

SquareLED - Aura Bar & Matrix Beam Light 100

Safety FIND THE FEED CABLE IN YOUR ELECTRICITY METER (UK)

Radio Thermostat Clock

Electro Magnetic Compatibility (EMC) Warning. Important notes for users in the U.K. FCC declaration. Caution. Fuse

INSTALLATION AND OPERATION M

Dragonfly Quad. User Manual V1.4. Order code: EQLED101

INSTRUCTIONAL MANUAL FOR LCD ZOOM MICROSCOPE

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01

ISP-W 350 till 1200 ISP-R 350 till 1200 ISP-B 350 till 1200 ISP-Motiv 450 till 950 with receiver RF Edition: 05/16 Nr

Video Wall Display User s Manual

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area

16 Amp Electronic 24 Hour/7 Day Time Controller

Re:connect M 203. RS232 Interface Revox. Dominating Entertainment. Revox of Switzerland. E 2.03

L632RG. User's Manual. DMX Address Chart RG 8 GOBO TWINKLING LASER SHOW SYSTEM

Digital Economy Seven Programmer

TUC: Universal thermostat

Manual for WMR-252 built-in receiver with universal dimmer

Programmable Video Signal Generator VG-880. Instruction Manual. Ver 1.10

Instructions for Use P.154-UP (9/4) P.155-UP (9/8) P.150-UP-12 (9/12) P.150-UP-16 (9/16)

A new generation of access control.

Owners SW-LCD 2.0 Manual & Specifications

PLL2210MW LED Monitor

ORDER CODE: EQLED65 USER MANUAL

8000 Plus Series Safety Light Curtain Installation Sheet ( CD206A/ CD206B )

4-PROJECTOR BAR WITH 3 X 9W LEDS AND 1 X 1W FLASH LED USER GUIDE

RADIO RECEIVER RGBW CONTROLLING LED STRIP COMMON ANODE

TP7001 Range Electronic 7 Day Programmable Room Thermostat. Danfoss Heating. Installation Guide

AVS50 USER GUIDE. 2.4GHz Audio/Video Sender System - AVS50

L-clickInstallation. Easy Quick Cost-effective

24 Hour & 7 Day Digital Immersion Heater Timeswitch Article

Schneider Industries SAS MTN5812../MTN MTN Time switch

Marine LCD Display MV-1504/1704/1904/2104

BY-HPE11KTA. Operating Instructions. Coaxial - LAN Converter with PoE function. Indoor Use Only. Model No. Attached Installation Guide

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

EC5415B. B-Tronic EasyControl. Assembly and Operating Instructions. Wall/hand-held transmitter, 15-channel, bidirectional

AristoMig U320w 208/230/400/460/475/500 V 3~ 50/60 Hz With cooling unit and central connection

Programmable Power Supplies 188 W 384 W R&S HMP Series

ivw-fd122 Video Wall Controller MODEL: ivw-fd122 Video Wall Controller Supports 2 x 2 Video Wall Array User Manual Page i Rev. 1.

KING-METER USER GUIDE SW-LCD

Integre4. Audiophile integrated amplifier. v1.2

VBOX III 100Hz GPS Speed Sensor. User Guide. Page 1 of 21. VBOX III SPS User Guide

Instructions for Use P.160-AP-8 (13/8) P.160-CP-8 (13/8) P.160-CP-12 (13/12) P.160-CP-16 (13/16)

For installation queries contact Customer Services (0) TCR IP 4 Operating instructions

COMFORT COMFORT CALL OWNER S MANUAL CALL SYSTEM P/N P BASE STATION & RF WIRELESS MODULE. Complete Control from TOTALINE

SINGLE ZONE CLIMATE ZONING SYSTEM. Technical Manual. Polyaire Pty Ltd

TVAC20000 User manual

NEO-STB-0004 Neo-Flash 300 RGB User Manual

The Admiral Type 4 family of safety light curtains is the ideal solution for the protection of the majority of high-risk industrial applications.

Dimming actuators GDA-4K KNX GDA-8K KNX

192 Channel DMX Controller

USER GUIDE IRLEDS SERIES - LED PAR PROJECTORS WITH INFRARED REMOTE CONTROL

OLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide

Supply voltage 230 V AC Service button 1. Power connector Light track contacts Service LED 1, red

USER MANUAL. 27 Full HD Widescreen LED Monitor L27ADS

USER MANUAL. Kramer Electronics, Ltd. Models:

INSTRUCTION MANUAL. Controller CLT-500 / RG-500

Operation Manual TX20 1/8 DIN Microcomputer Based ph/orp Controller with relays

2-output DALI controller

ENGLISH (BioKey - IR Modus with Remote Control)

AC diagonal module Ø 200 mm

Data Acquisition Networks. Installing and Configuring the DM01 Hardware

In-Ceiling Electric Motorized Front Projection Screen Evanesce Series. User s Guide

User manual BETSO TCD-1. 1 Compact Time Code display. 1 Copyright BETSO ELECTRONICS Ltd.

PL2410W LCD Monitor USER'S GUIDE.

PLL1920M LED LCD Monitor

AP-40. AP-40 Series Features Industry s smallest-sensor head Ultra lightweight High-speed response Two-color LED digital pressure display

Dimensions. Model Number. Electrical connection. Features. Pinout Product information. Indicators/operating means. LGS25 Serie.

TDDFM14 OWNER S MANUAL

IDsn ODsn Series Product Manual

CH1 CH2 CH3 CH4. Master /Fade CH5. 600s CH6. 60s SC1 SC2 SC4 SC3 SC5. SC6 Off/Pro. AL Fade 6 Pro. User guide

Assembly. Front view. LEDs. Parametrization interface. Power Bus

The user manual of LED display screen and RH-32G control card.

Transcription:

EN-Installation manual 0 1 1/1 DM CONTROL MODULES (VCS-R-DM-..) VCS-R-DM-S, VCS-R-DM-E, VCS-R-DM-V B0-010-011-1 QUICK START INSTALLATION

1. BEFORE YOU BEGIN Symbols are used in the user s manual to improve your orientation. The following table includes their graphical images and meanings: SYMBOL ATTENTION! Warning/caution MEANING DO NOT OVERLOOK! Important instructions YOU WILL NEED NOTE Practical tips and information TECHNICAL INFORMATION More detailed technical information LINK Refer to other parts/sections of the manual Declaration of conformity Declatarion of confortmity for SM control modules is part of declaration of conformity for air curtains STANDESSE Comfort. Declaration of conformity is located at www.vv.cz Air curtains STANDESSE Comfort are produced with universal connection interface. Air curtains STANDESSE Comfort can be controlled by one of following control modules. Control modules (SM, DM or DA) are required accessories for VCS... air curtains and has to be ordered separatelly. Air curtains STANDESSE Comfort is connected with control module by Quick connection sockets

. UNPACKING.1 CHECK THE SHIPMENT 1x x 0 1. MAIN PARTS.1 DM control module (suitable with all types of air curtains) Types of DM control modules: VCS-R-DM-S (Suitable with air curtains without heating - VCS-x-xxS- ) X (WHITE)

. MAIN PARTS VCS-R-DM-V (Suitable with air curtains with water coil VCS-x-xxV- ) 0 1 X (BLUE) X (WHITE) VCS-R-DM-E (Suitable with air curtains with electric heater VCS-x-xxE- ) X (NONE) X (RED) X (BLUE) X (WHITE) 0 1. Function overview of DM control modules Air curtains execution Control module Air only (VCSx-xxS...) DM (VCS-R-DM-S) With electric heater (VCSx-xxE...) DM (VCS-R-DM-E) With water coil (VCSx-xxV...) DM (VCS-R-DM-V) Type of control Manual Manual Manual Speed of the fan *** *** *** Electric heater regulation x steps x Water heater regulation x x Zone valve Control panel connection Radio signal Radio signal Radio signal Number of quick connection sockets 1 Door switch behavior ON/OFF ON/OFF ON/OFF Timer x x x Temperature measurement x x Room thermostat Operation state indication LED LED LED Radio signal indication LED/ BEEP sound LED/ BEEP sound LED/ BEEP sound Cleaning interval indication x x x Water heater anti-frezze protection x x x Aftercooling of electric heater x 0 seconds x Chaining of the air curtains In radio signal range In radio signal range In radio signal range

. INSTALLATION.1 MECHANICAL INSTALLATION.1-1 Insert control module to the air curtain.1- remove blinding sticker When DM contol module is used it is necassary to remove blinding sticker of operation signalization

. INSTALLATION.1 ELEKTRO INSTALLATION Installation must be carried out by a professionally trained electrical worker. All applicable national regulations and directives must be observed. The electrical schematics on the product take priority over those presented in this manual! Prior to installation, check to see if the terminal markings correspond to the markings on the electrical connections diagram. When in doubt, contact your supplier and do not connect the air curtain under any circumstances. Never reach inside the air curtain unless the main electrical supply has been turned off! Air curtains STANDESSE Comfort is connected with control module by Quick connection sockets 6

. INSTALLATION.1-1 Insert control module to the air curtain VCSx-xx-S-... VCS-R-DM-S-. 1 1 0 1 1 1 WHITE WHITE 6 6 FUSE 8 8 Door contact X1 L N PE L N PE CYKY Cx1, 0V/0Hz

0 1. INSTALLATION VCSx-xx-E-... VCS-R-DM-E-. 1 1 1 1 WHITE WHITE 6 6 8 8 1 1 BLUE 6 6 BLUE Door contact 8 8 1 1 RED RED 6 6 FUSE 8 8 X1 L1 L L N PE L1 L L N CYKY Cx... 00V/0Hz PE 8

0 1. INSTALLATION VCSx-xx-V-... VCS-R-DM-V-. 1 1 WHITE 6 8 6 8 WHITE 1 1 BLUE 6 6 BLUE Door contact 8 8 FUSE X1 L N PE M ZV- L open L N L N PE CYKY Cx1, 0V/0Hz Room thermostat TER-P 9

. INSTALLATION. CONTROL PANEL.-1 Control panel description VCS-R-DM-S VCS-R-DM-V ON OFF radio signal ON OFF 1. heating step radio signal heating OFF 0 1. fan speed. fan speed 1. fan speed 1. fan speed. fan speed. fan speed VCS-R-DM-E ON OFF 1. heating step radio signal heating OFF 0 1. heating step 1. fan speed. fan speed. fan speed.- Control panel mechanical installation 10

0 1. INSTALLATION.- Control panel connection DM control panel (radio signal) Esc Auto Man SET TIME CLEAN RESET SET TIME SWITCH - Range of radio signal in open space is 100m - DM control panel need for the operation x AAA baterry. (Included in delivery) Setting of radio communication frequency setting is required..-.1 Single air curtain operation The DM control panel is paired* with DM control module from production. (*Pairing - DM control module is set up on the same frequency as control panel is) If pairing procedure is required (in case of control panel baterry changing, change of control panel, ) -.-1 PAIRING PROCEDURE 11

0 1. INSTALLATION.-. Chained air curtain operation (more air curtains controlled by one control panel) 0 1 To control more air curtains by one control panel, it is neccessary to make pairing (*Pairing - set up DM control module on the same frequency as control panel is using) Each control module DM (air curtain) can operate with up to 60 control panels. This gives an possibility to control air curtain by more (up to 60pcs) control panels in radio signal range..-1 PAIRING PROCEDURE If there is use more then one control panel for chained air curtains. The air curtains will work according last received radio command from control panel. The other control panel will signalizate its own last setting!! 1

. INSTALLATION. PAIRING PROCEDURE Each air curtain can be controlled by its own DM control panel, or one DM control panel can control all paired air curtains in range of radio signal. This functionality can be set by PAIRING. SET LED PROG SIG LED SIG OPR (Signalization of operation) SET LED (programing radio signal indication) SIG LED (radio signal signalization) PROG (programing button) SIG OPR.-1 Pairing of DM control panel with DM control module (air curtain) 1x PROG SET LED SHINING (READY FOR PAIRING max.1 sec.) 0 1 HOLD sec. To add another DM control panel to paired control panel memory of DM control module repeat pairing procedure (part:.-1) with another DM control panel. (DM control module has memory for 60pcs of DM control panels). SET LED x FLASH (PAIRING IS DONE) 1

. INSTALLATION.- Deleting of paired control panel memory HOLD PROG 10 sec. SET LED SHINING SET LED OFF (PAIRING IS DELETE).- Deleting one paired DM control panel from paired control panel memory 1x PROG SET LED SHINING (READY FOR max.1 sec.) 1x PROG SET LED FLASH 0 1 SET LED OFF (PAIRING IS DELETE) SET LED x FLASH HOLD sec. 1

. EXTERNAL ACCESSORIES.1 CONNECTION OF EXTERNAL ACCESSORIES When connecting external accessories, the electricity to the air curtain must be turned off. All external control components must be connected according to the electrical schematic. The connectors must be connected to the electrical board using reasonable force and always vertically to the base..1-1 Door contact - Isolated switching contact with a maximum voltage of 1V. Cable - Dual-core cable with a diameter of 0. mm. - Maximum length: 0 m. For DM and DA control modules only! Connectors on the DM control modules: / Not included in delivery..1- Zone valve ZV- - Zone valve for water heater regulation - Cable Three core cable with diameter of 1, mm, 0 V/ 0 Hz. For VCS-R-DM-V control modules only! Connectors on the DM control modules: 1 / / Not included in delivery. 1

. EXTERNAL ACCESSORIES.1- Room thermostat TER-P - Room thermostat for water heater regulation - Cable Two core cable with diameter of 1, mm, 0 V/ 0 Hz. For VCS-R-DM-V control modules only! Connectors on the DM control modules: / Not included in delivery. Accessories overview Required accessories Optional accessories Air curtains execution Control module "External temperature sensor" Air only (VCSx-xxS...) DM (VCS-R-DM-S) With electric heater (VCSx-xxE...) DM (VCS-R-DM-E) Water coil regulator X X With water coil (VCSx-xxV...) DM (VCS-R-DM-V) X X X "ZV- (Zone valve)" Door switch X X X Door contact -1-1 -1 Room thermostat X X TER-P Ceiling mounted brackets VCS-KONZ-STR. VCS-KONZ-STR. VCS-KONZ-STR. Wall mounted brackets VCS-KONZ-STE. VCS-KONZ-STE. VCS-KONZ-STE. EXIT sign VCS-EXIT VCS-EXIT VCS-EXIT 16

6. INITIAL START-UP Before putting the air curtain with DM control module into operation, check the following: Have any tools or other objects which could damage the curtain been left inside it? Is there a proper supply of electricity and, if necessary, heating water? Has the air curtain been properly closed? Has the control module been connected properly? Before putting the curtain into operation, read carefully: Full manual for OPERATION AND MAINTENANCE (delivered with control module). CONCLUSION If you have any doubts or questions, do not hesitate to contact our sales or technical support department. Before operation and maintanance, thoroughly read the section Safe use of air curtains. It contains all instructions on the safe and correct use of the product. CONTACT Address VV, s.r.o., Poděbradská 89, 0 09 Pardubice, Czech Republic Internet: http://www.vv.cz/contact.distribution.php 1