Timer Modules. MEU11 24 Hour Module, MEU17 7 Day Module (Without Housing)

Similar documents
Timer Modules. EL11 24 Hour Module EL17 7 Day Module. Installation & Operating Instructions

16 Amp Electronic 24 Hour/7 Day Time Controller

7 Day Digital Light Switch with Optional Dusk Start

7 Day Digital Time Switch

7 Day Digital Programmer 3 Channel Surface Mount

Digital Time Switch. Installation & Operating Instructions

2 Hour Electronic Boost Timer

Digital Economy Seven Programmer

7 DAY DIGITAL LIGHTSWITCH WITH OPTIONAL DUSK START INSTALLATION & OPERATING. Cat No. ZV700 INSTRUCTIONS

7 Day Digital Programmer

24Hour/7Day Electronic Timeswitch

1. General Information:

WiFi Controlled Fused Spur Time Switch

24 Hour & 7 Day Digital Immersion Heater Timeswitch Article

INSTALLATION & OPERATING INSTRUCTIONS SINGLE/TWO CHANNEL 24HR/7 DAY TIMER. Cat No. TR671/TR672TOP

TDDFM14 OWNER S MANUAL

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

Nixie Clock Type Quattro'

TU-8A. 8 Channel Digital Timer Unit. Programming Guide

Programmable Room Thermostat With RF

Sensor module. Safety instructions. Function Correct use. Product characteristics. Structure of the device. Operation. Ref.No.

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

Philips LightMaster. KNX Timeclock Installation and Operation Manual

Nixie Clock Type Frank 2 Z570M

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

7 SEGMENT LED DISPLAY KIT

Automatic Transfer Switch Control PLC Operator s Manual

Dial Ezy INSTRUCTION MANUAL N IRRIGATION CONTROLLER 4 or 6 Station Model SUITABLE FOR INDOOR USE ONLY OTHERWISE WARRANTY IS VOID

FW/S Digital time switch 2CDG120039R0011 D GB F I E NL. Installation and operating instructions FW/S DCF antenna GPS antenna SELV MENU

XTM72E & F Real-Time Clock Modules


Nixie Clock Type Frank 3

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

Documentation VFD clock 8 a clock

SCS318. User Instructions. SCS318 comprising of SCS317 7 Day Wireless Programmable Room Thermostat and SSR303 Receiver

TORK DGU100/DGUM100 7 DAY DIGITAL TIME SWITCH INSTALLATION AND OPERATING INSTRUCTIONS READ INSTRUCTIONS CAREFULLY BEFORE SETTING UNIT

talento 800 Series 365-Day One, Two and Four Circuit Electronic Time Controls Functional Description

ACT 10 Digital Keypad Operating & Installation Instructions This manual is found at

XTM72 Exerciser Timer Module

Tempus Lux Digital Photoelectric Switch D GB CZ BZT Installation and operating instructions BZT27731

DD E SIG N E D & E N GIN EE R E. Holman Garden Lights App Instruction Manual. Android Android manual

LP20. Installation & User Guide. Dual Channel Programmer. Part number 25039DR

Solid-State Digital Timer

Installation & Programming Manual. Please read before using this timer.

Industriefunkuhren. Technical Manual. IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C / AFNOR NF S87-500

VNS2210 Amplifier & Controller Installation Guide

SINCE User Manual 7 DAY PROGRAMMABLE DIGITAL TIMER MODEL PS-100. The best solutions for automation and protection.

DIGITAL TIME SWITCH 7 DAY WITH INPUT DGU100A DGUM100A DGLC100A DGLC200A

Inserting the batteries. Basic settings of the remote control

Waterline Room Controller - Type WLCT3

TP7001 Range Electronic 7 Day Programmable Room Thermostat. Danfoss Heating. Installation Guide

DTS400B - DZS400BP 3/9/07 10:14 AM Page 1

Lifestyle. Dual Channel Programmer. for heating AND hot water. Installation and User Instructions DUAL CHANNEL ISSA

BT Diverse Repeater. User Guide

Assembly Instructions And User Guide. Nixie FunKlock. FunKlock Issue 4 (1 February 2017)

18W Low Energy Dusk-Dawn Bulkhead E-290B

ServicePlus S17R Series 2 User Operating Instructions

GRANT RF CONTROL CENTER INSTALLATION INSTRUCTIONS Always disconnect battery while servicing or modifying the electrical system of the vehicle.

Commander 384. w w w. p r o l i g h t. c o. u k U S E R M A N U A L

Nixie Tube Clock Type Marsden

Index. English. English User Manual Eco.X

Wired Troubleshooting Manual

Catalogue Ignitors and power switches for HID

Operating Instructions 07/2007 Edition. SINAMICS G130/G150 Line harmonics filter. sinamics

Weekly Time Switch. Rated time Time setting range Time division 24 hrs x 7 days 00:00 to 23:59 1min

DRIVER 230 CPL 3 zone weekly programmer using power line carriers

S-Series Digital Thermostat. Instruction Manual Model No ST620RF

SHUTTLE WITH INFRA-RED DETECTION SAS2-IR

ALM-6813/6812 INSTALLATION AND PROGRAMMING MANUAL

Radio Thermostat Clock

SINGLE ZONE CLIMATE ZONING SYSTEM. Technical Manual. Polyaire Pty Ltd

21 Channel Light Show PWM LED Controller with Remote Control

User Guide. Centrex Recording Interface

ST625TX Digital Room Thermostat

SINAMICS G130 / G150. Line harmonics filter. Operating Instructions 05/2010 SINAMICS

Art M Digital codelock module

DLP200M 2 Relay Module for Heating and Cooling Plants

RD RACK MOUNT DIMMER OWNERS MANUAL VERSION /09/2011

8 PIN PIC PROGRAMMABLE BOARD (DEVELOPMENT BOARD & PROJECT BOARD)

VNS2200 Amplifier & Controller Installation Guide

RAMMER INSTRUCTION MANUAL FITTING & OPERATING INSTRUCTIONS NEL PROGRAMMER. NSTAR Si MODELS

INSTALLATION & USER GUIDE

Digital Lighting Systems, Inc.

1 EX5. Technical Characteristics. Dimensions

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

Electronic 7 User Operating Instructions

Arduino Nixie Clock Classic Rev4 and Rev5 All In One Modular Rev2

Arduino Nixie Clock Classic Rev4 and Rev5 All In One

Installation and Operation Manual. YMP Series Signal Programmer

Aspect 2 Circuit Digital Scene Control

Operating instructions Retro-reflective sensor. OJ50xx laser / / 2010

Schneider Industries SAS MTN5812../MTN MTN Time switch

SBL /SBLG Series Wireless Clock

ZoneTouch V2 Zone Control System User Manual

REGO Start&Go USER MANUAL

Arduino Nixie Clock Modular Rev3

RT505TX Programmable. The RT505TX can be used with any of these receivers RXBC605 RXWBC605 RXVBC605 RXST MHz

DLP600M 6+1 Relay Module for Heating and Cooling Plants

28 4K LED monitor. User Manual M284K

Electrical connection

Transcription:

Timer Modules MEU11 24 Hour Module, MEU17 7 Day Module (Without Housing) EMU11 24 Hour Module, EMU17 7 Day Module (With Housing Giving panel mounting facility) Installation & Operating Instructions

1 1. General Information These instructions should be read carefully and retained for further reference and maintenance. 2. Safety Before installation or maintenance, ensure the 3V DC supply to the timer module is switched off. It is recommended that a qualified electrician is consulted or used for the installation of this timer module and install in accordance with the current IEE wiring and Building Regulations. Check that the total load on the circuit before attempting to use the time module for your OEM application. 3. Technical Specifications General Requires an external diode, resistor and relay to switch mains voltage. Manual Override ON/OFF until next programme. Operating Temperature 0 C to +55 C. Power Reserve Non replaceable rechargeable factory fitted battery, Metal Hydride, 1000 hours. CE Compliant.

2 MEU11 & EMU11 24 Hour Modules 24 Hour Time Period 4 ON/OFF programmes. MEU17 & MEU17 7 Day Modules 7 Day Time Period 6 ON/OFF programmes, daily, weekly, weekend or weekday options. 4. Contents 1x Timer module. 1x Panel mount bezel. 1x Tamper proof cover. 4x Surface mount stand offs (length 10mm). 2x Panel mount bolts. 2x Self-tapping screws (No. 4 x 5/8in) for panel mount bolts. 2x Self-tapping screws (No. 6 x 3/8in) for attaching bezel to EMU11. 5. Installation

3 Panel Mounting For panel mounting (in panels up to 7.0mm thick with the cut-out as shown in figure 2) the EMU11/17 should be snapped into the bezel supplied and secured in place by the use of the 2x No. 6 x 3/8 in self-tapping screws provided (as shown in figure 3). When selecting a position for the unit, bear in mind that a clearance behind the front panel surface of 26.0mm is required over the full area of the panel cut-out. The unit is designed to be mounted from the front of the panel by the following procedure;

4 5.1 Insert the 2 bolts provided in the locations as shown in figure 4. 5.2 Then insert the 2x No.4 x 5/8 in self-tapping screws into the bolts and engage thread. 5.3 Make connections to the unit by wires terminated in a Molex 4 way 7720 or similar connector from behind the panel. 5.4 Insert the EMU11/17 complete with bezel into the panel and tighten up the 2x No.4 selftapping screws. The ears on the bolts will rotate as you tighten to clamp the unit to the panel. Surface Mounting The EMU11/17 without bezel can be surface mounted using the 4 securing holes as shown in figure 5. The unit can be stood off from the mounting surface by 10mm using the 4 spacers if required. Screws are not provided and it must be remembered that if used in this way the EMU11/17 must be installed within a housing or cubicle to prevent access to the mains terminations.

6. Connection (All models) Single Resistor PSU (MEU11 & MEU17 only) 5 Two Resistor PSU gives Optimum EMC Performance (MEU11 & MEU17 only)

6 All Types Connections Pin 1: Common. Pin 2: Positive battery charge plus relay current. Min 0.50 ma (No relay). Pin 3: Relay connection. Pin 4: Output & relay connection. NPN open connector. Max 10 ma, 47 V A Molex 7720 4 way connector or similar is recommended. MEU11 and MEU17 Typical Usage The examples in figs 6, 7 and 8 show the module driving a Shrack 48V relay with power derived from the mains. Type RP330048 or RP331048 (Changeover contracts). In these configurations the relay pulls in at 47V and is held at above 24V with mains voltages down to 200V. EMU11 and EMU17 Typical Usage In this case the circuit in fig 6 can be used with a 10K, 3W resistor in place of the 15K, 2W resistor shown and a 1.3W zener must be connected between pins 1 and 2 of the module. The circuit in fig 7 can be used with two 5K1, 1.5W resistors in place of the 7K5, 1W resistors shown and a 1.3W zener must be connected between pins 1 and 2

of the module. The circuit in fig 8 can be used with a 330nF, X 250V AC capacitor instead of the 220nf capacitor shown and a 1.3W zener must be connected between pins 1 and 2 of the module. In all cases the zener is 47V and its cathode is connected to module pin 2. Capacitor PSU (MEU11 & MEU17 only) 7

7. Programming Instructions 24 Hour Model 8 Change Button sets Hours and Minute times and self cancelling override Easy view 24 hour digital clock/timer display 7 Day Model Change Button sets Hours and Minute times and self cancelling override Easy view 24 hour digital clock/timer display Day indicator 1 = Monday 7 = Sunday Programme Button used to select the clock time and the 4 ON/OFF programme times and to review them Output Status once set showing unit either ON or OFF Output Status showing unit either ON or OFF Programme Button used to select the clock time and the 6 ON/OFF programme times and to review them once set

5 7.1 Programming Overview To enter the programming mode, press and hold the Program button for 2 to 3 seconds and then release the button. Only two setting buttons are required during the programming process. The Change button is used to set the hours and minutes, the Program button is used to move to the next stage of the programming process. Each time the Program button is pressed the display will flash either the hours or the minutes in turn, starting with the clock then the first ON time, first OFF time, second ON time and so on. Note: Button pauses greater than 1 minute during programming will result in an automatic return to operating mode. 7.2 Normal Operating Mode In normal operation the unit will display the correct time with the colon flashing. The output status will be shown by either ON or OFF on the display. 24 Hour Version 7 Day Version

6 7.3 Setting Clock & Programming After Reset To clear the memory and reset the unit press hold down the Change and Program button until the display goes blank. Release both of the buttons. After a few seconds the display will show the clock with the hour digit blinking. For the 7 day version there will be a dot flashing over number 1 which is Monday and 7 being Sunday. Press the Change button to select your current day. Once this is complete press the Program button to move to setting the clock. You are now in the clock setting mode at the beginning of the programme sequence To set the hour for the clock press the Change button to advance the hour setting. For a rapid change of the hour setting hold down the Change button and release when the correct hour value is selected. Press the Program button once and the minutes will flash, press the Change button to advance the minutes setting to the correct value required. Again you may hold down the Change button for a rapid change of the minutes if you wish to do so.

Press the Program button once, the clock is now set and you are ready to enter the first ON time. You will now find the hour digits flashing if you own the 24 hour models and if you own the 7 day models you will see the first five dots flashing which represents Monday to Friday. 7 7.4 Programme 1 ON time (7 Day Models Only EMU17 & MEU17) (For EMU11 & MEU11 follow from the next bullet point, programmes will run on a daily Basis) Press the Change button to select the appropriate group you require your programme to run for; you can also set individual days. Press the Change button to select the hour you require for the programme. Press the Program button to confirm the hour and advance to the minute setting.

8 Press the Change button to select the minutes you require for the programme. Press the Program button to confirm the minutes for the ON time and move on to setting programme 2 ON. Repeat the steps from section 7.4 Programme 1 ON time for additional programmes if required. Note: The 24 hour models have 4 programme memory slots, and the 7 day models have 6 programme memory slots. If you wish to exit the program mode at anytime, press and hold the Program button until you are back at the current time. IMPORTANT: Once programming has been completed, the unit will show an OFF status by default. If you require power output now, press the CHANGE button once. This will override the unit until the next programmed OFF time. If you do not do this, the unit will simply turn ON at the next scheduled ON time (even if this is the following day). 7.5 Program Review When in operating mode press the Program button for 3 seconds and the clock symbol, hours and minute s symbol on the display will flash, this is

9 review mode. If any changes are required to the current set programmes press the Change button to start programming mode and then follow steps from Programme 1 ON time. 7.6 Cancelling Programmes To clear all programmes, press and hold down the Change and Program buttons until the display goes blank. Release both buttons and after a few seconds you will be prompted to set the clock. Once set you can re-enter your programme times. 7.7 Clearing Programmes Any individual programme can be cancelled by clearing its ON and OFF time. Follow the steps as mentioned in section 7.5 Program Review until you reach the program you wish to cancel. Press the Change button until the hour digits show --: and press the program button to clear the programme. 7.8 Self-Cancelling Override To change the output status from ON to OFF or vice versa during normal operation press the Change button. If the output status is OFF, it will change to ON until the next programmed OFF time. If the output is ON, it will change to OFF until the next programmed ON time.

8. Battery The modules are supplied with factory fitted with a non-replaceable, re-rechargeable, Metal Hydride battery back-up with 1000 hours reserve. Note: To preserve battery life, it is not recommended that these modules remain disconnected from a charging source for a period of more than six months. 10 1 Year Guarantee If you experience any problems, do not immediately return the unit to store, please telephone our helpline. In the unlikely event of this product becoming faulty due to defective material or manufacture, please return it to your supplier within 1 year along with proof of purchase and it will be replaced free of charge. Note: a proof of purchase is required in all cases. For all eligible replacements (where agreed by Timeguard) the customer is responsible for all shipping/postage charges outside of the UK. All shipping costs are to be paid in advance before a replacement is sent.

If you experience problems, do not immediately return the unit to the store. Telephone the Timeguard Customer Helpline; HELPLINE 020 8450 0515 or email helpline@timeguard.com Qualified Customer Support Co-ordinators will be on-line to assist in resolving your query. For a product brochure please contact: Timeguard Limited. Victory Park, 400 Edgware Road, London NW2 6ND Sales Office: 020 8452 1112 or email csc@timeguard.com www.timeguard.com 67-057-97 (Issue 4) Zerofour December 2016