We will look first at the cable, and then the transceivers (which act as both transmitter and receiver on each end of the fiber cable).

Similar documents
Selection of a cable depends on functions such as The material Singlemode or multimode Step or graded index Wave length of the transmitter

VersiVision. FVTM4BCxA-CE / FVRM4BCxA-CE MULTIPLEXER SYSTEM 4-CHANNELS DIGITALLY ENCODED VIDEO 2-CHANNELS BI-DIRECTIONAL DATA

Cable Jacket - The outermost layer of the fiber cable. Application: Types Single mode Multi mode. Simplex or Duplex available

Introduction to Fibre Optics

VersiVision. FVTMHA0xA / FVRMHA0xA 16-CHANNEL DIGITALLY ENCODED VIDEO 1-CHANNEL BI-DIRECTIONAL DATA MULTIPLEXER USER S MANUAL.

Model OTDV Broadcast Transport Links OPERATING MANUAL

Fiber Optic Testing. The FOA Reference for Fiber Optics Fiber Optic Testing. Rev. 1/31/17 Page 1 of 12

Introduction to Fiber Optic Cable Technology Jerry Bednarczyk, PE Course Content

VersiVision. FVTM2BBxA / FVRM2BBxA 2-CHANNELS DIGITALLY ENCODED VIDEO 2-CHANNELS BI-DIRECTIONAL DATA 2-CHANNELS BI-DIRECTIONAL AUDIO

SSA Fibre-Optic Extender 160 Fibre Installation Guidelines Version 1.2

Gigabit Multi-mode SX to Single Mode LX Converter. User s Manual NGF-728 Series. Warning COPYRIGHT

40G SWDM4 MSA Technical Specifications Optical Specifications

Stretch More Out of Your Data Centre s Multimode Cabling System

SPCxxB10100D SFP+ Dual Fiber CWDM CWDM / 10dB / 10 Gigabit Ethernet

User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W

Job Aid Server and CSS Separation Avaya S8700 Media Server

The Road to Single Mode: Direction for choosing, installing and testing single mode fiber

SFCxxB16GExD SFP Dual Fibre CWDM ITU CWDM / 16dB / Gigabit Ethernet

Tech Breakfast: Fibre Optic Cabling

40G SWDM4 MSA Technical Specifications Optical Specifications

SFCxxB24GExD SFP Dual Fibre CWDM CWDM / 24dB / Gigabit Ethernet

100Base-FX Multi-mode to 100Base-FX Single Mode Converter. NXF-708 Series User s Manual

Module 11 : Link Design

Pluggable Transceivers Installation Guide

ODW-621. RS-232 Point-to-point applications

Connectix Cabling Systems

Fiber Optics Redefined

10G SFP+ Modules. 10G SFP+ Module Series

OPERATOR MANUAL OSD351 FIBRE OPTIC CCTV TRANSMITTER CARD

EDS-210A Series. 8+2G/9+1G-port Gigabit unmanaged Ethernet switches. Introduction. Specifications. Industrial Ethernet Solutions

Fibre Channel Fiber-to-Fiber Media Converters

400G-FR4 Technical Specification

FiberLink 3500 Series Transceivers

CC-Link IE Controller Network Compatible. CC-Link IE Controller Network Recommended Network Wiring Parts Test Specifications

SPDxx040100D SFP+ Dual Fibre DWDM 100GHz DWDM / 40 km / 10 Gigabit Ethernet

OLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide

CFMFFxxxx-2xx User s Guide Slide-in-Module Media Converter Fast Ethernet, ATM, SONET, or Gigabit

Small Form-Factor Pluggable (SFP) Module Installation Guide

OPERATOR MANUAL OSD8865 DIGITAL TRIPLE VIDEO FIBER OPTIC RECEIVER

COPYRIGHT 2011 AXON DIGITAL DESIGN B.V. ALL RIGHTS RESERVED

EDS-G205/G308 Series. 5G and 8G-port full Gigabit unmanaged Ethernet switches. Introduction. Specifications. Industrial Ethernet Solutions

SECTION 4 TABLE OF CONTENTS

3G-SDI Extender via Single Mode Fiber LC Simplex Connector Extends 3G-SDI Link Up To 20 Kilo Meters

FiberLink 3350 Series

Single mode 9/125µm, duplex

EDS-G205-1GTXSFP/G308 Series

DATA SHEET. Two (2) fibers Detachable DisplayPort 1.2 Extender, DPFX-200-TR

Industrial 10/100 Base-TX to 100 Base-FX Media Converter NS-200AFC-T/NS-200AFCS-T/NS-200AFCS-60T +12 ~ +48

User s Guide TN-GB-SM512. Gigabit Interface Converter (GBIC) Transceiver Modules

COE Group plc. Contents

Assembly code page 46. Cable code page 47. Assembly classes page 48. Polarization maintaining assemblies page 52

Fibre Optic Modem ODW-611

Fiber Optic Meter Fiber Optic Source

OPTICAL FIBRE CABLE NETWORK 2004/1

Instalaciones de fibra optica en entornos de centro de datos y campus para suportar 40, 100G y mas

FiberLink 7142 Series

L-Band Fiber Optic Link

Ordering Information. Industrial Ethernet Solutions

EDS-G205/G308 Series. 5G and 8G-port full Gigabit unmanaged Ethernet switches. Introduction. Specifications. Industrial Ethernet Solutions.

100G-FR and 100G-LR Technical Specifications

Cisco 10GBASE Dense Wavelength-Division Multiplexing SFP+ Modules

Scope: Using Wave Division Multiplexing (WDM) for the Protection Data Interface (PDI) of the 7SD5 / 7SD61.

LONWORKS Fibre Optic Converter

Fibre Optic Modem ODW-622

Delaware County Community College Project # Marple Campus Renovation - Phase % Construction Documents November 23, 2011

SIMATIC NET. Network components Transceiver SFP/SFP+/SCP/STP. Introduction 1. Safety notes 2. Description 3. Assembling 4.

OFI-400 Series Optical Fiber Identifiers. OFI-400 Series Models

MAXCOM PRODUCT SPECIFICATIONS FIBER OPTIC VIDEO / AUDIO / ASI LINK. Model MX3257HD. Description. Features. Model Selection Guide

FTS-M12G-S85L-55M. SFP 1000Base-SX, 850nm, multi-mode, 550m

DATA SHEET. Four (4) fibers Detachable HDMI Extender, HDFX-150-TR

DATA SHEET. Two (2) fibers Detachable DisplayPort Extender, DPFX-100-TR

Light Source. Specification & User Manual

FIM-108 MATRIX FIBER INTERFACE INSTRUCTION MANUAL

DATA CENTER OPTICAL ASSEMBLIES TO SUPPORT QSFP, CFP AND CXP INDUSTRY STANDARD PINOUT CONFIGURATIONS

FiberLink 3355 Series

EDS-G205/G308 Series. 5G and 8G-port full Gigabit unmanaged Ethernet switches. Introduction. Specifications. Industrial Ethernet Solutions

OptEnet OC48 Regenerator Module User Manual

OTLT / OTLR 3000 Manual. L-Band Fiber Optic Link MHz INSTRUCTION MANUAL

Click & Go. LWL-NE4-Katalog. Click & Go Modular Solutions. Subject to technical changes! 1

10Gbps SFP+ Optical Transceiver, 10km Reach

ISO/IEC testing LC to LC (Duplex Multimode) DTX-MFM

SPECIAL SPECIFICATION 6735 Video Optical Transceiver

DATA SHEET. Two (2) fibers Detachable HDMI 2.0 Extender,

SERIAL DIGITAL VIDEO FIBER OPTIC TRANSPORT & DISTRIBUTION MODULAR SYSTEM FOR HDTV & SDTV

Mini HD-SDI Optical Transceiver Model No : VCF-MF01TXRX

RGB COMBINERS. 2.0 mm Narrow Key FC/PC or FC/APC Termination Excellent for Confocal. Ø900 µm Loose Hytrel Tube with the wavelength Laser Sources

FTS-R27G-S31L-002DI. Multirate SFP 125Mbps-2.67Gbps, 1310nm, single-mode, 2km

1995 Metric CSJ SPECIAL SPECIFICATION ITEM 6031 SINGLE MODE FIBER OPTIC VIDEO TRANSMISSION EQUIPMENT

HDMI Extender via Single SC Fiber Support 3D/4K2K Up To 10Km In One Single-mode Fiber

Lensed Fibers & Tapered Ends Description:

Cisco 10GBASE Dense Wavelength-Division Multiplexing XFP Modules

MICROSENS. Fast Ethernet Switch Modul 4x 10/100Base-TX, 1x 100Base-FX. Description. Features

OFI Optical Fiber Identifier User s Guide

WWDM Transceiver Update and 1310 nm eye-safety

TC3301. User's Manual

IEC G-port Gigabit smart rackmount Ethernet switches STAT PWR1 PWR2 FAULT FDX/HDX MODE. Warranty

TC Mbps - 622Mbps FIBER OPTIC MODE CONVERTER/REPEATER (Rev A0.1) User's Manual

OPERATOR MANUAL OSD553 TRIPLE VIDEO FIBRE OPTIC RECEIVER

Fibre optic router for TP/FT-10 LRW-112PP

Uniprise Solution Brochure. North America/CALA.

Transcription:

Nuclear Sensors & Process Instrumentation Fiber Cable Basics Fiber-optic communication is a method of transmitting information from one place to another by sending light through an optical fiber. The light forms an electromagnetic carrier wave that is modulated to carry information. First developed in the 1970s, fiber-optic communication systems have revolutionized the telecommunications industry and played a major role in the advent of the Information Age. Because of its advantages over electrical transmission, the use of optical fiber has largely replaced copper wire communications in core networks in the developed world. The process of communicating using fiber-optics involves the following basic steps: Creating the optical signal using a transmitter, relaying the signal along the fiber, ensuring that the signal does not become too distorted or weak, and receiving the optical signal and converting it into an electrical signal. The complete fiber optic link is represented in Figure 1 below. Figure 1: Model of "simple" fiber optic data link We will look first at the cable, and then the transceivers (which act as both transmitter and receiver on each end of the fiber cable). Fiber Optic Cable A fiber optic cable is a cylindrical pipe. It may be made out of glass or plastic or a combination of glass and plastic. It is fabricated in such a way that this pipe can guide light from one end of it to the other. Basically, a fiber optic cable is composed of two concentric layers termed the core and the cladding. These are shown on the right side of Figure 2. The core and cladding have different indices of refraction with the core having n1 and the cladding n2. Light is piped through the core. A fiber optic cable has an additional coating around the cladding called the jacket. Core, cladding and jacket are all shown in the three dimensional view on the left side of Figure 2. The jacket usually consists of one or more layers of polymer. Its role is to protect the core and cladding from shocks that might affect their optical or physical properties. It acts as a shock absorber. The jacket also provides protection from abrasions, solvents and other contaminants. The jacket does not have any optical properties that might affect the propagation of light within the fiber optic cable. Figure 2: Fiber Optic Cable, 3 dimensional view and basic cross section

Light is guided down the core of the cable because the core and cladding have different indices of refraction with the index of the core, n1, always being greater than the index of the cladding, n2. Figure 3 shows how this is employed to effect the propagation of light down the fiber optic cable and confine it to the core. Figure 3: Propagation of a light ray down a fiber optic cable As illustrated a light ray is injected into the fiber optic cable on the right. If the light ray is injected and strikes the core-tocladding interface at an angle greater than an entity called the critical angle then it is reflected back into the core. Since the angle of incidence is always equal to the angle of reflection the reflected light will again be reflected. The light ray will then continue this bouncing path down the length of the fiber optic cable. If the light ray strikes the core-to-cladding interface at an angle less than the critical angle then it passes into the cladding where it is attenuated very rapidly with propagation distance. When it comes to mode of propagation, fiber optic cable can be one of two types, multi-mode or single-mode. These provide different performance with respect to both attenuation and time dispersion. Multimode Multimode fiber optic links are the most popular in industrial and customer premise environments because they generally have the lowest cost cabling and transceivers. However, they have limited lengths of up to 4 or 5 km. To form a multimode link you must use multimode cable (either 50 or 62.5 µm core diameter) and multimode transceivers. With multimode fiber the light travels multiple paths down the cable and actually bounces side to side. Because of the nature of multimode fiber the distance it can go is limited primarily by a phenomenon called modal dispersion or multimode distortion. Figure 4 - Multimode Cable - Transmission Singlemode and Long Haul Singlemode fiber optic links are less popular because of their higher cost (both cabling and transceivers) but they can operate over extended distances up to 120 km or more. To form a singlemode link you must use singlemode cable (8, 9 or 10 µm core diameter; 9 µm is most common) and singlemode transceivers. With singlemode fiber the light travels in a single path down the cable. This is more efficient and allows for the extended distances. Singlemode fiber is not affected by modal dispersion so its distance is limited mostly by the power and sensitivity of the transceivers being used. 2

Figure 5 Singlemode Cable - Transmission Transceivers (Transmitters/Receivers) and Connectors The Transmitter component of Figure 1 serves two functions. First, it must be a source of the light coupled into the fiber optic cable. Secondly, it must modulate this light so as to represent the binary data that it is receiving from the Source. With the first of these functions it is merely a light emitter or a source of light. With the second of these functions it is a valve, generally operating by varying the intensity of the light that it is emitting and coupling into the fiber. The Receiver component of Figure 1 again serves two functions. First, it must sense or detect the light coupled out of the fiber optic cable then convert the light into an electrical signal. Secondly, it must demodulate this light to determine the identity of the binary data that it represents. In total, it must detect light and then measure the relevant Information bearing light wave parameters in the premises fiber optic data link context intensity in order to retrieve the Source's binary data. Transceiver is the industry term for the transmitter/receiver unit as a pair. When manufacturers refer to a fiber optic port, they are typically referring to both transmit and receive connection required for a duplex fiber optic link. Thus a switch with 2 fiber ports will have 2 complimentary pairs of transmit and receive connections, or 2 transceivers. Optical fibers are connected to terminal equipment by optical fiber connectors. These connectors are usually of a standard type such as SC, ST, or LC (the 3 types featured in Ultra Electronics, NSPI s switches). Fibers are terminated in connectors so that the fiber end is held at the end face precisely and securely. The end face is where light (and subsequently the fiber optic signal) enters and leaves the optic core. A fiber-optic connector is basically a rigid cylindrical barrel surrounded by a sleeve that holds the barrel in its mating socket. The mating mechanism can be "push and click", "turn and latch" ("bayonet"), or screw-in (threaded). Regardless of what type of connection, it is essential that the connector used is matched to the type of fiber (MM or SM) it will terminate, that the connector is installed per manufacturer specifications, and that the end face of the connection remains clean at all times. Ultra Electronics offers two distinct types of transceivers; 1x9 (SC or ST connectors) and SFP (LC connectors). 1x9 Transceivers with SC or ST Connectors These are offered on the fiber optic fast Ethernet (100 Mbps) ports. The 1x9 refers to the industry-standard pin-out of 1 row by 9 pins. Ultra Electronics offers these transceivers with dual ST or SC style connectors. They are available as Multimode, Singlemode, or Singlemode Long Haul. Other variations are available as special order. 3

1x9 Transceiver with SC Connectors 1x9 Transceivers with ST Connectors SFP (Small Form Pluggable) Transceivers (aka Mini-Gbic) with LC Connectors These are offered on the fiber optic gigabit Ethernet (1000 Mbps) ports. These transceivers plug into a cage assembly that is already in place in the Ultra switch. They are more compact than the more traditional 1x9 style transceivers. Ultra offers these transceivers with dual LC connectors. They are available as Multimode, Singlemode, or Singlemode Long Haul. Other variations such as CDWM (Coarse Wavelength Division Multiplexing) are available as special order. SFP Transceiver out of cage SFP Transceiver inserted in cage Selecting the Proper Components for a Fiber Optic Network Link There are 4 primary considerations when selecting the proper components for a fiber optic link: 1. The length of the fiber link from end to end 2. The bandwidth (i.e. 100mbps or 1Gbps) required based on the applications and information that will be sent over the link 3. The estimated amount of total attenuation over the link (a factor of fiber optic cable properties and the amount and quality of the splice/connector points along the fiber from end to end). 4. The power budget of the transceiver pairs being used to generate and accept the fiber optic signal. Using the Reference Tables at the end of this note as guidelines (and using attenuation characteristics for the specific fiber optic cable installed or proposed for use), a user can develop an acceptable link-loss budget and select the proper transceivers for their system. Please note that type of connector has no influence on the loss along a system. Example An industrial user has a series of Ethernet devices operational at Location A. They are building a new facility 8km away. At this distance they are certainly going to have to plan on using single mode fiber. They want to transmit (or plan to transmit) at Gigabit speeds. The SM fiber that they have decided to use attenuates at a rate of.3/km. There will be 3 splices along the route and then connectors at each end. Cable attenuation = 8km x.3/km = 2.4 Splice loss = 3 splices x.2/splice =.6 Connector loss = 2 connectors x 1/connector = 2 4

Total loss along physical link = 5 Safety factor of 25% = 1.25 Total loss budget = 6.25 Looking at the Gigabit fiber transceiver performance specifications, we can see that the single mode Gigabit fiber transceiver has a worse-case power budget of 11 so this should work satisfactorily in this proposed fiber link. Troubleshooting Fiber Optic Links If installed correctly, fiber optic links can provide years of worry free connectivity for users, but like all communications systems, there are times when some troubleshooting may be required. There is expensive cable test equipment such as power source/meters and OTDRs available on the market from a number of manufacturers which are optimal for testing and verifying physical links. For most users, the economy of owning equipment like this does not make sense, so the following are some quick and easy steps to try before calling in a vendor to test your system. 1. Make sure that all of your connectors are clean. Even a little bit of dust, dirt or grease on a connector face can significantly degrade a fiber signal. This includes the main fiber optic link as well as any patch cables that you may be using. When cleaning, it is important to use lint free swabs or wipes, preferably of a clean room quality. These can be used dry or wet (with 99% isopropyl alcohol solutions). Make certain that you are not cleaning an active fiber as the laser can cause permanent damage to your eyes should you look into the end face. Additionally, it is not necessary to scrub the end face, rather to just gently wipe it clean and then recheck the link. If additional cleaning is required simply repeat this process. 2. Ensure that the cable type you are using matches the transceiver type. That is, MM cable requires MM transceivers. 3. Ensure that the patch cords that you are using match the link fiber cable. Again MM needs to be used with MM. Additionally, it is important that 62.5um is used with 62.5um and 50um with 50um. This is a very common and easy to make mistake. If the fiber cores are not aligned correctly significant attenuation will occur. 4. Make sure that all connectors are plugged completely into their proper ports. Again if end faces are lined up correctly with transceivers and/or mated fiber ends, the system may fail due to excess attenuation. 5. Make sure that the transmit cable at the near end is the receive cable at the far end. Their needs to be a crossover for a fiber link to work correctly. Be sure to factor in all patch cords that may be used. Fiber Transceiver Performance Specifications Reference Tables Ultra Electronics Fiber Transceivers Performance Specifications: Ethernet Type Mode Data Rate (Mbps) Signal Rate (MHz) Wave-length (nm) IEEE Standard Fast Ethernet Multi 100 125 1310 100BaseFX Fast Ethernet Single 100 125 1310 100BaseFX Fast Ethernet Single long haul 100 125 1310 100BaseFX Gigabit Ethernet Multi 1000 1250 850 1000BaseSX Gigabit Ethernet Single 1000 1250 1310 1000BaseLX Gigabit Ethernet Single long haul 1000 1250 1310 1000BaseLX Gigabit Ethernet Single long haul 1000 1250 1550 1000BaseLH Gigabit Ethernet Single long haul 1000 1250 1550 1000BaseLH 5

Ultra Electronics Fiber Transceivers Performance Specifications (continued): Power Budget (Power - Sensitivity) Transmitter Power* Receiver Sensitivity* Ethernet Type Mode Typical Worst Min. Typ. Max. Min. Typ. Max. Fast Ethernet Multi 14 (-17 minus -31) 10 (-21 minus -31) -21-17 -14 -- -34-31 Fast Ethernet Single 20 (-11 minus -31) 16 (-15 minus -31) -15-11 -8 -- -36-31 Fast Ethernet Singlelong haul 31 (-3 minus -34) 29 (-5 minus -34) -5-3 0 -- -36-34 Gigabit Ethernet Multi 12 (-6 minus -18) 9 (-9 minus -18) -9-6 -3 -- -- -18 Gigabit Ethernet Single 14 (-6 minus -20) 11 (-9 minus -20) -9-6 -3 -- -- -20 Gigabit Ethernet Gigabit Ethernet Gigabit Ethernet Singlelong haul Singlelong haul Singlelong haul 22 (-1 minus -23) 19 (-4 minus -23) -4-1 2 -- -- -23 22 (-1 minus -23) 19 (-4 minus -23) -4-1 2 -- -- -23 25 (2 minus -23) 23 (0 minus -23) 0 2 5 -- -- -23 *Note: For transmitter power, the higher the number the better. The opposite is true for receiver sensitivity, the lower the number the better. Fiber Cable Parameters (typical) Cable Size (core/cladding) (µm) Mode Wavelength (nm) Connector Losses ( per connection) Splice Loses (db per splice) Distance Losses ( per km) Multimode Modal Dispersion* (MHz x km) Singlemode Dispersion (ps/nm x km) 62.5/125 µm Multi 850 nm 1 0.2 3.3 300 -- 50/125 µm Multi 850 nm 1 0.2 2.7 700 -- 62.5/125 µm Multi 1310 nm 1 0.2 1 500 -- 50/125 µm Multi 1310 nm 1 0.2 0.8 800 -- 9/125 µm Single 1310 nm 1 0.2 0.5 -- 3.5 9/125 µm Single 1550 nm 1 0.2 0.25 -- 19 8/125 µm Single 1550 nm 1 0.2 0.2 -- 19 Note: These are just guideline numbers. Refer to your cable specifications for more accurate values. 6

Calculating Fiber Optic Distances There are two primary ways to calculate how far you can go with your fiber optic links. To be safe you should go by the shortest result from the two methods, if you use both such as you can with Multimode fiber. Also, you should design for up to a 25% safety margin to be conservative and allow for degradation of the signal and cable over time. Method 1: Modal Dispersion for Multimode links only Maximum Distance = modal Dispersion/Signal rate Speed Mode Wavelength (nm) Cable Diameter (µm) Modal Dispersion* Signal Rate (MHz) Max. Distance Based on Modal Dispersion Fast Ethernet Multi 850 nm 62.5/125 300 125 2.4 km Fast Ethernet Multi 850 nm 50/125 700 125 5.6 km Fast Ethernet Multi 1310 nm 62.5/125 500 125 4 km Fast Ethernet Multi 1310 nm 50/125 800 125 6.4 km Gigabit Ethernet Multi 850 nm 62.5/125 300 1250 240 m Gigabit Ethernet Multi 850 nm 50/125 700 1250 560 m Gigabit Ethernet Multi 1310 nm 62.5/125 500 1250 400 m Gigabit Ethernet Multi 1310 nm 50/125 800 1250 640 m Method 2: Based on Optical Budget Power Budget = Transmitter Power Receiver Sensitivity Spare Optical Budget = Power Budget Power Losses (splices and connectors) Maximum Distance = Spare Optical Budget/Distance Losses Speed Mode Cable Size Wavelength Power Budget (Worst case) Typical Losses* Spare Power Distance Losses Max. Distance Fast Ethernet Multi 62.5/125 µm 1310 nm 10 6 4 1 4 km Fast Ethernet Multi 50/125 µm 1310 nm 10 6 4 0.8 5 km Fast Ethernet Single 9/125 µm 1310 nm 16 6 10 0.5 20 km Fast Ethernet Long haul 9/125 µm 1310 nm 29 6 23 0.5 46 km Gigabit Ethernet Multi 62.5/125 µm 850 nm 9 6 3 3.3 0.9 km Gigabit Ethernet Multi 50/125 µm 850 nm 9 6 3 2.7 1.1 km Gigabit Ethernet Single 9/125 µm 1310 nm 11 6 5 0.5 10 km Gigabit Ethernet Long haul 9/125 µm 1310 nm 19 6 13 0.5 26 km Gigabit Ethernet Long haul 9/125 µm 1310 nm 19 6 13 0.25 52 km Gigabit Ethernet Long haul 9/125 µm 1310 nm 23 6 17 0.2 85 km Note: Typical losses include 2 (two connectors), 3 (safety margin) & 0.4 (two splices) = 6 (rounded up) 7

Nuclear Sensors & Process Instrumentation Fiber Optic Maximum Distance Summary Speed Mode Cable Size Wavelength IEEE Recommended Distance Max. Distance Based on Power Budget* Max. Distance Based on Modal Dispersion* Fast Ethernet Multi 62.5/125 µm 1310 nm 2 km 4 km 4 km Fast Ethernet Multi 50/125 µm 1310 nm 2 km 5 km 6.4 km Fast Ethernet Single 9/125 µm 1310 nm 15 km 20 km -- Fast Ethernet Long haul 9/125 µm 1310 nm -- 46 km -- Gigabit Ethernet Multi 62.5/125 µm 850 nm 220 m 0.9 km 240 m Gigabit Ethernet Multi 50/125 µm 850 nm 550 m 1.1 km 560 m Gigabit Ethernet Single 9/125 µm 1310 nm 5 km 10 km -- Gigabit Ethernet Long haul 9/125 µm 1310 nm -- 26 km -- Gigabit Ethernet Long haul 9/125 µm 1310 nm -- 52 km -- Gigabit Ethernet Long haul 9/125 µm 1310 nm 70 km 85 km -- *Note: These numbers are just guidelines and are highly dependent on your cable and transceiver specifications. Ultra Electronics NUCLEAR SENSORS & PROCESS INSTRUMENTATION 707 Jeffrey Way, PO Box 300 Round Rock, TX 78680-0300 USA Tel: +1 512 434 2850 Fax: +1 512 434 2901 e-mail: fiberop@ultra-nspi.com www.ultra-nspi.com Ultra Electronics, Nuclear Sensors & Process Instrumentation is a business name of Weed Instrument Co., Inc. Ultra Electronics reserves the right to vary these specifications without notice. Ultra Electronics 2010. Printed in the USA. 03/10 8