LANsense Modular Patch Panel for 24 Snap-in Connectors 1 HU. empty. Clip-on. with Sliding mechanism. Black or white INSTALLATION GUIDE

Similar documents
Modular Six pack Patch Panel. for 24 Snap-in Connectors. Clip-on and Shutters. with Sliding mechanism INSTALLATION GUIDE

LANmark PCB patch panel, 1HU INSTALLATION GUIDE. LANmark PCB patch panel, 1 HU

INSTALLATION GUIDE. LANmark-OF Zone Distribution Box

LANmark. Copper Cabling Solutions

LANmark-OF ENSPACE Patch Panel

HCS - HES Cabling Systems

HD Flex Patch Panel. ASSEMBLY VIEW (FLEX1UPN** shown) FS128B. CONTENTS: (#) indicates FLEX4UPN** quantity

Medium Box for Cable Termination

2.1 Kit Contents 2.2 Elements needed from the FIST installation kit 2.3 Tools 2.4 Cable preparation table

3 Closure preparation 3.1 Work-stand 3.2. Opening FIST-GCOG2-Dx Preparing drop cable with micro-tubes

FIST-MB2-S. FIST Medium Box for Cable Splicing Only. 4 Cable installation. 1 Introduction. Contents. 2 General. 5. Fiber routing to individual trays

3M Distribution Box (DDB)

FOSC-450D. Fiber Optic Splice Closure. 1 Introduction. Content. 5 Cable termination. 6 Fiber routing. 2 General. 7 Installation of the gel block

FOSC-600 C and D I N S T A L L A T I O N I N S T R U C T I O N

NC-1000 INSTALLATION MANUAL NC-1000 FIBRE OPTIC CROSS-CONNECTION SYSTEM

INSTALLATION INSTRUCTIONS

24-Fiber LANLINXS (Model # ) 48-Fiber LANLINXS (Model # ) User Manual

FIST-GCOG2-Dx6. Follow all local safety regulations related to optical fiber plant elements.

3M Fiber Optic Wall Mount Enclosure 8430 Series

PREMIUM 5e F/UTP PRODUCTS

Caution. Hanging the Screen:

CONNECTING THE FUTURE 19" LINXS LIGHTWAVE INTEGRATED CROSS-CONNECT SYSTEM USER MANUAL

OASIS CSI (Certified Security Integrators) Direct Attach Warranty for ESS Devices

6000 Series Patch Panel Terminating Instructions

Robert Burén. Product Manager. Nexans Cabling Solutions. 10G Solutions

High Density Block BRCP. HD BRCP- 128/192/256 pair. Installation Instructions

Ordering Guide. for FIST-GSS2 product range

Cable and Power Management Open-Frame Rack Cable Managers

SECTION COMMUNICATIONS HORIZONTAL CABLING

MT-RJ SECURE Product Expansion Now 10 Variants of the MT-RJ SECURE Products

SJOF-BS604B. Fiber Optic Splice Closure User Manual Rev.1

3M SLiC 530/533/733-2 Port 0.61 Cable Entry Bracket 3M SLiC 530/533/733-2 Port-MSM 0.61 Cable Entry Bracket

FOSC 450 C6 and D6 Closures

INSTALLATION INSTRUCTIONS MO023A

GCO2-BC6/16-XX GCO2-BD6/16-XX GCO2-BE6/16-XX

HDBT Installation Guide

HDBaseT Installation Guide

Follow The Leader In Shielded Technology

Volition TM RJ45 K5e Jacks

AUDIO ROOF KIT P/N , , APPLICATION BEFORE YOU BEGIN KIT CONTENTS. Instr Rev Page 1 of 6

California Polytechnic State University ITS Telecommunications PART 1 GENERAL SECTION AUDIO VISUAL STATION CABLES 1.

CATEGORY 6 CABLING SOLUTIONS

SUBCARRIER TRANSFER FILTER INSTRUCTION BOOK IB622702

RAIL D-SUB BACKSHELLS

19" TiRAX cabinet system. from page 3. 19" NETcell cabinet system from page 31. Open 19" racks from page 43

DS1 Cross-Aisle Panel

IP-LINX. Installation Guide

Replacing the PanelMate epro PS, PanelMate epro PS EE, and PanelMate epro PS OD 7685x-12 Series Backlight Assembly

Service Call: Fiber Optic Installation and Repair

IP-LINX Fiber :: X-XXXX

SECTION 4 TABLE OF CONTENTS

LCS 2 RJ 45 Cat. 6A HD panels and units

VITALink Taped Splice Straight Through Crimp

FIBRE OPTIC CABLE SOLUTIONS

LGX Compatible (LSX) Connector Module) User Manual)

3M Cold Shrink Foldback Splice Jacket Kit

OFDC-B8-72. Outdoor fiber distribution closure. 6 Closing. Content 1 Introduction. 7 Re-entry. 2 Kit content. 3 Closure preparation

Crimp & Cleave Termination Instructions for SEL ST Connectors

Smart Choices. for Data Center

Tender Report for Supply and installation of LAN in *Biomedical Imaging and Bioinformatics Lab*

Product information 19" 1U HD Patch Panel 48xRJ45/s, Cat. 6A, gray, fully populated

Installation Instructions

2179-CD Series Fiber Optic Splice Closure. Installation Instructions

INSTALLATION INSTRUCTIONS

Best Friends General Trading FZE

Coastal Carolina University RE-BID WILLIAMS BRICE RENOVATION AND REPAIR October 19, 2018 Construction Documents

K-LWLH1 2.0 m AA. K-LWLH m AA. K-LWLH m AA

SCdefault. 900 Installation instructions. Accessories Part No. Group Date Instruction Part No. Replaces :36-29 Sep

Copyright Black Box Corporation. All rights reserved.

FT-45 Ordering Information

INFRASTONE BLACKSTONE 10G 6A(U/UTP) Europe, Middle East and Africa regions UNLIMITED USAGE 1

Indoor cabling LAN Cabling Systems

Cabling and Completing Assembly of the Cisco TelePresence System 1000

TITLE: FIBER OPTIC SHOCK FIXTURES

Industrial Monitor Update Kit

GF-KSW-48 Series of Fiber Optic Distribution Box. Instruction Manual

FIST-GCO2-OTIAN I N S T A L L A T I O N I N S T R U C T I O N

Compact Module. Category 6 FTP Cabling System

Single sensor setup with NIVEL210

Optical Distribution Box 300 Installation Guide. Version : R0.0

READ THESE INSTRUCTIONS COMPLETELY AND CAREFULLY

Installation instructions Cable transit device Roxtec RS ES Ex

Installation Manual IPT Installation of skillet systems with 125 A track current. MV a-E.

MRX1 1. Getting to know your MRX1 wireless controller

Coyote popup display set up instructions

Instructions. Cable with Armor F CAUTION. October Rev A

Assembly instructions

Connectivity accessories by Nestor Cables

PRODUCT DESCRIPTION N3S

Section Communications Optical Fiber Backbone Cabling

LCS2 Cat. 6 RJ 45 Patch panels and units

INSTRUCTION MANUAL NPPA-TT-S PATCH PANEL Easy Patch 96 Bantam (TT) Jacks, Solder lugs

Bionic Elephant Trunk. Assembly Instructions

DREAMOC DIAMOND 4K - ASSEMBLY GUIDE VERSION ORIGINAL ASSEMBLY GUIDE

CANNON STANDARD page 1 of 18. Cm5 MOTOR CONNECTOR

Structured Cabling Introduction & Installation Guide

PATCH PANEL Easy Patch INSTRUCTION MANUAL

Service Parts Diagrams. For Model: 10/20/09 Service Parts Diagrams for the Rear Projection SMART Board 3000i-DV Interactive Whiteboard 1

Gel-sealed in-line fiber optic closure

A. All communications equipment rooms shall be installed in a neat and workmanlike manner.

Transcription:

LANsense Modular Patch Panel for 24 Snap-in Connectors 1 HU empty Clip-on with Sliding mechanism Black or white INSTALLATION GUIDE LANsense Modular Patch Panel for 24 Snap-in Connectors

Document information Document reference Release 2006 Published by Contact address LANsense MPP 1HU empty 24 Snap-ins Clip-on with Sliding 2006 Nexans Cabling Solutions Alsembergsesteenweg 2, b3 1501 Buizingen Belgium Phone +32 2 363 38 00 Fax +32 2 365 09 99 Website E-mail www.nexans.com/ncs info.ncs@nexans.com Important Notice The information contained in this document has been carefully checked and is assumed to be entirely correct and reliable at the time of publishing. However, Nexans Cabling Solutions reserves the right to make such changes to its products or its documentation as it deems necessary, in order to make improvements. Nexans Cabling Solutions rejects all responsibility for the use made of its products or of its documentation. In this document, no mention is made of rights with respect to trademarks or tradenames which may attach to certain words or signs. The absence of such mention, however, in no way implies that there is no protection. 2006 Nexans Cabling Solutions Installation is to be performed by qualified service personnel

LANSENSE MODULAR PATCH PANEL 1 HU EMPTY FOR 24 SNAP-IN CONNECTORS WITH CLIP-ON WITH SLIDING MECHANISM During installation, care of LANmark-6/7 products is much more critical than when installing LANmark-5 or other Nexans Category 5e products. The high levels of performance can only be guaranteed if the installation procedures are followed. Special attention must be given to keep the length of untwist of the pairs. Two patch panels are available depending on the type of connector used. Please verify in the table below if the panel is suited for the connectivity to be installed. The LANmark Snap-in connector with rear cover has to be used for screened solutions in order to ensure contact between the foil of the cable and the clips of the Modular Patch Panel. N881.411 LANsense Modular patch panel 1HU, empty, for 24 EVO snap-in connectors, with sliding mechanism and clip-on, Black N881.415 LANsense Modular patch panel 1HU, empty, for 24 EVO snap-in connectors, with sliding mechanism and clip-on, White N881.211 LANsense Modular patch panel 1HU, empty, for 24 GG45 snap-in connectors, with sliding mechanism and clip-on, Black N881.215 LANsense Modular patch panel 1HU, empty, for 24 GG45 snap-in connectors, with sliding mechanism and clip-on, White 1HU 3HU Assemble the cage nuts to both side flanges of the frame or cabinet according to the cabinet layout. Nexans Cabling Solutions Installation Guide LANsense MPP - 3

Remove the front plate of the patch panel. Mount the Modular patch panel on the assembled cage nuts. Pull the cables through the rear side of the patch panel. Loosely organise the cables in the patch panel coming from the outlets. Easily fix the cables under the clip-on. Nexans Cabling Solutions Installation Guide LANsense MPP- 4

Terminate the connectors on the cables as per the Snap-in Installation Guides Snap the connectors into the Patch Panel by hooking the top of the connector under the front plate Push the back of the connector into its aperture. Important : Make sure to leave the OUTER jacket under the clip-on cable guide. Nexans Cabling Solutions Installation Guide LANsense MPP - 5

To remove the connector : put a very small screwdriver under the connector in the hole. Manage and dress the cables into the rack or frame, this will add to the bending radius of the cables and facilitate access to the patch panel post installation when the patch panel is closed after termination. If the cables are dressed and managed into the frame or cabinet with the patch panel closed, it is often not possible to pull the patch panel forward for access later on, due to the tightness of the cables. Keep a minimum of 35 cm distance between the front side of the patch panel and the fixing point of the cables in the cabinet or frame. Nexans Cabling Solutions Installation Guide LANsense MPP- 6

When provided, gently prepare the small LANsense I/O cable connector from the back of the patch panel to the front in the centre. Take the front mounting plate. Connect the LANsense I/O cable connector to the connector on the back of this plate. The connector will only fit one way. Gently slide back the Patch Panel into the rack. Close the patch panel using the black fastener clips on the front of the patch panel. Nexans Cabling Solutions Installation Guide LANsense MPP - 7

Slide in the identification label. Optional tie-wraps can be fitted at the back of the patch panel to fix the cables if needed. Use a tie-wrap to fix the LANsense I/O cable in the middle on the back of the patch panel. Nexans Cabling Solutions Installation Guide LANsense MPP- 8

Earthing : The Patch Panel is automatically earthed if used in conjunction with the Nexans Quick Mount Cabinet. Where the patch panel is mounted onto a painted or coated frame, two additionnal earthing tags, suitable for 9 mm spade connectors, are available in the patch panel at each end of the clip-on cable guide as indicated with the arrow above. An optional earthing wire connecting the top drawer can be added with a metal screw as shown in the picture. IMPORTANT REMARKS : It is recommended to use a patch guide for each 48 ports. The recommended patch guides are the 1HU (102.117) for all installations excluding LANmark-7 (GG45) where the 2HU (102.127) must be used. The 2HU patch guide can also be used for LANmark-6 installations if enough space is available in the rack or cabinet. NOTE : Only start testing the links or channels when the connectors are installed in the patch panel. Nexans Cabling Solutions Installation Guide LANsense MPP - 9