HEVAC HTC DIGITAL SERIES STEP BY STEP GUIDE FOR COMMON PROGRAMMING

Similar documents
Innovative Air Systems ABN When Calling For Support Quote:.doc

SINGLE ZONE CLIMATE ZONING SYSTEM. Technical Manual. Polyaire Pty Ltd

FN:4181M5.DOC MC4181N SERIES MASTER CLOCKS MC4181N

EC7000, EC7004 and EC7005 Single Channel Electronic Time Controls

Automatic Transfer Switch Control PLC Operator s Manual

HS-509 VIBRATION TRIP MODULE

All real signals have scale factor 10. Integer, Index and Logic has always scale factor 1.

SSPT724A Timer Quick Start Guide

Tri-level Control HF Sensor

SCS318. User Instructions. SCS318 comprising of SCS317 7 Day Wireless Programmable Room Thermostat and SSR303 Receiver

User interface. Abbreviations / Meanings

OPERATION AND MAINTENANCE

Overview: Specifications: Installation Instructions:

A Motor can be in many groups, by assigning additional channel# on it.

FN:4181NX_M1.DOC MC4181NX MASTER CLOCK MC4181NX

Sample BD Tech Concepts LLC

USER & ENGINEER INSTRUCTION MANUAL

PT Two (2) Channel 365 Day 24 Hr. Timer/Controller

Installation and Operation Manual. YMP Series Signal Programmer

TDEPD. Field-Programmable Pressure Switch/Transducer with Integrated LED Display. Programming Sequence Manual

Comfort System T-32-P Universal Thermostat. Operation Manual

Sample BD Tech Concepts LLC

12months. on-site warranty. DZE ELECTRONIC PRESSURE SWITCH for detection of overload per EN 81 2 featuring two adjustable switching points

TP7001 Range Electronic 7 Day Programmable Room Thermostat. Danfoss Heating. Installation Guide

SR - 516D DESK TOP DMX REMOTE STATION. Version: Date: 05/16/2013

talento 800 Series 365-Day One, Two and Four Circuit Electronic Time Controls Functional Description

COMFORT COMFORT CALL OWNER S MANUAL CALL SYSTEM P/N P BASE STATION & RF WIRELESS MODULE. Complete Control from TOTALINE

GreenParking. Commissioning guide. GreenParking

Westerstrand T/T- display

Operation Guide 6022 ENGLISH

Master Clock Controller. User Guide. pyramidtimesystems.com

U8 Timer. Owner s Manual MODEL NO. 2000U8. Model and serial number may be found at the rear of the feeder base.

Defrost Control Installation and Programming of Version 3.1 Cards

Troubleshooting Guide for the ESP MC controller Feb Royce Mason

Installation & Operation Manual. BEC PM1 Controller Time/Flow/Volume Controller. Water Control Solutions

Master Clock Controller. User Guide. pyramidtimesystems.com

Master Clock Controller. User Guide. pyramidtimesystems.com

Danfoss Icon Programmable Room Thermostats, 230 V

Two (2) Channel 365 Day 24 Hr. Timer/Controllers

User Guide. Color Touchscreen Programmable Thermostat. ComfortSense Model: 13H /2017 Supersedes

Master Time Clock MTC Users Manual

Installation Instructions

OTM FREQUENCY AGILE 750MHz F.C.C. COMPATIBLE TELEVISION MODULATOR INSTRUCTION MANUAL

DCL Time Controller WTDCL. Universal Lighting Technologies is a subsidiary of Panasonic Electric Works Co., Ltd., a member of the Panasonic Group

DCP100 Digital Control Programmer Specifications

7 Day Digital Programmer 3 Channel Surface Mount

Lifestyle. Dual Channel Programmer. for heating AND hot water. Installation and User Instructions DUAL CHANNEL ISSA

AHP-1200CPV Cold/Warm Plate Product Manual Volume 1.3

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

16 Amp Electronic 24 Hour/7 Day Time Controller

T775L Series 2000 Electronic Stand-Alone Staging Controller

Digital Ratio Controller

SECURITRON PRIME TIME MODEL DT-7 INSTALLATION AND OPERATING INSTRUCTIONS

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

RD RACK MOUNT DIMMER OWNERS MANUAL VERSION /09/2011

DA-88 QUICK TIPS (VERSION 4 SOFTWARE)

Do not insulation test (Megger) any circuits connected to this product.

MODEL OTM-4870 FREQUENCY AGILE 870MHz F.C.C. COMPATIBLE TELEVISION MODULATOR

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

Luminaire installation box Surface-mounted box Ceiling installation box

Cronotermostato Digitale

Softwired Clock. Total Lighting Control. Catalog Number: RCLK8SWS DESCRIPTION FEATURES. Installation Instructions IMRCLK8SWS 1

ComfortChoice Touch Thermostat. Designed for ZigBee R Wireless Technology USER GUIDE

Global Water Instrumentation, Inc.

USER S GUIDE. 1 Description PROGRAMMABLE 3-RELAY LOGIC MODULE

Ambiflex MF620 USER GUIDE

Aspect 2 Circuit Digital Scene Control

Provides an activation of Relay 1 triggered by Input 1. The function also provides an option for reverse-logic on the activation of Input 1.

Kramer Electronics, Ltd. USER MANUAL. Models: VS-162AV, 16x16 Audio-Video Matrix Switcher VS-162AVRCA, 16x16 Audio-Video Matrix Switcher

Slide 1. Flip-Flops. Cross-NOR SR flip-flop S R Q Q. hold reset set not used. Cross-NAND SR flip-flop S R Q Q. not used reset set hold 1 Q.

INSTALLATION & OPERATING INSTRUCTIONS SINGLE/TWO CHANNEL 24HR/7 DAY TIMER. Cat No. TR671/TR672TOP

AES-402 Automatic Digital Audio Switcher/DA/Digital to Analog Converter

1 Overview. 2 Specifications. 3 Installation Instructions. HPT724 Programmable LCD Timer PN 52765:A 1/25/06 ECN Product Installation Document

Handy tips Watching live TV Using the TV guide Watching Catch-Up TV Adding more channels Watching movies...

Multi Channel Programmable Filter-Amplifier. User Manual I-II III V-U SAT. Stop Channel SAT Slope Start Channel SAT ON / OFF.

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

OP5. Preprogrammed, configurable controller for simple applications

Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features

Operating Instructions. Room temperature controller with clock

A6 OPERATING INSTRUCTIONS

TITLE BOX PAGE ONLY. DO NOT MAKE FILM DO NOT PRINT. MATERIAL: White 16lb (60g/m sq), uncoated, prefer recycled stock Ink: Black

ST9100C User Guide. Features

USER MANUAL AL-Control 1 PRO

TDDFM14 OWNER S MANUAL

Operating Instructions for Throttle Valves Using VRC Valve Positioner

Softswitch128TM. SwitchingSystem. Setup and Maintenance Guide

Chronothermostat IRIDE. User Manual

INSTRUCTION & OPERATION MANUAL. MODEL MMW-05 (5kW) MUROMACHI MICROWAVE FIXATION SYSTEM

UTH-170 Installation and Manual

DIGITAL TIME SWITCH 7 DAY WITH INPUT DGU100A DGUM100A DGLC100A DGLC200A

EN Wireless programmable thermostat

SAUTER flexotron RDT405 Manual

BooBox Flex. OPERATING MANUAL V1.1 (Feb 24, 2010) 6 Oakside Court Barrie, Ontario L4N 5V5 Tel: Fax:

EUROPEAN COMMUNITY DIRECTIVES

Model IQ4-PC User Manual Revision Date:

UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4

DAAB DB409 INSTRUCTION MANUAL FOR THE VFD-EL FREQUENCY CONVERTER. For the DAAB EP104 automatic control system with software version 4.

VTR8300 Series User Interface Guide Commercial and Hotel/Lodging HVAC Fan Coil Applications

AES-404 Digital Audio Switcher/DA/Digital to Analog Converter

2 CHANNEL RECEIVER DISPLAY POTENTIOMETER COM2 NC2 NO2

Transcription:

HEVAC HTC DIGITAL SERIES STEP BY STEP GUIDE FOR COMMON PROGRAMMING How to lock unlock controller. and UP button together for 5 (sec) until Loc- (unlocked), Loc L (setpoint adjustment only) or Loc H (controller totally locked) is displayed. - Simply press the up or down button to the lock status you require is displayed and press the TEMP/ACCEPT button. What to do if the controller displays HELP. - Turn the power off to the controller for at least 10 secs then turn it on. - Press all four buttons together for 5 secs till display reads CLR.n, press the up button for CLR.Y now press TEMP/ACCEPT button. This resets the controller and loads in a 2 Heat 2 Cool program with ON/OFF times Mon Fri 8-5.30PM. - Make sure to check the controller is wired to suit above application otherwise manual programming is advised. - It is advisable to check the controller displays the correct time and date which will be outlined below. How to change the clock. - Press and hold the TIME/ESCAPE button for 5 (sec) till ts 1 is displayed. - Press up button twice till Cloc is displayed. - Press up or down till correct hour is displayed - Press up or down till correct minute is displayed - Press the TEMP/ACCEPT - Done appears on the display - Press the TIME/ESCAPE How to change the date. - Press and hold the TIME/ESCAPE button for 5 (sec) till ts 1 is displayed. - Press up button three times till date is displayed

- Press up or down button till correct day of month is displayed, press TEMP/ACCEPT - Press up or down button till correct month is displayed, press TEMP/ACCEPT - YEAr is now displayed, press TEMP/ACCEPT then press up or down button till 20 is displayed - Press up or down till correct year is displayed - - Day is now displayed, Monday = d AY 1, Sunday = d AY 7, press up or down button till correct day is displayed, press TEMP/ACCEPT button. - DonE is displayed, press TIME/ESCAPE BUTTON. How to load pre-loaded programs 1 HEAT 1 COOL, 2 HEAT 2 COOL, 2 HEAT 2 COOL PLUS ECONOMY CYCLE, HEATING AND COOLING VALVE PLUS HWP & CWP RELAYS. 5 (sec) till LOAD is displayed till Pr is displayed - Press up button till Pr 02 (1 HEAT 1 COOL) OR Pr 03 (2 HEAT 2 COOL) is displayed done is displayed - Press TIME/ESCAPE How to check the and/or change the current programmed on/off times. - Press TIME/ESCAPE 5 (sec) till ts 1 is displayed till CLr.n is displayed, Day 1 is displayed (Monday) - Keep pressing TEMP/ACCEPT to view the current programmed on/off times. These times can be altered simply by pressing the UP or DOWN button and pressing the TEMP/ACCEPT. - Once times have been checked or altered press the TIME/ESCAPE button twice to exit How to program after hours mode. - Press TIME/ESCAPE 5 (sec) till ts 1 is displayed - Press up button 7 times till Ahr is displayed

- Press up or down button till desired after hours time - Done appears - Press TIME/ESCAPE - The SYS ON LED will ONLY blink for the pre determined AHR time and only when after hours has been initiated When the controller displays VENT (VEnt) - VENT is caused by open circuiting the sensor wires B&M which operates the FAN only for a free cooling effect - On rare occasions VENT is displayed after a spike or loss of power to the controller. Refer to section What to do if HELP is displayed to rectify When the controller displays r OFF - By short-circuiting sensor terminals B&M the controller displays r OFF. This inturn disengages all outputs thus remotely turning the controller off. - Look for a switch on the sensor or mounted remotely, turn to the on position to rectify - You can also turn the controller off via the faceplate by momentarily pressing together the TIME/ESCAPE and down buttons. To turn the controller back on press the TEMP/ACCEPT button. To put the controller in after hours mode - Either press & hold momentarily the TEMP/ACCEPT & TIME/ESCAPE BUTTONS or short terminals M&XT via momentary make push button 24Hrs 7 Day a week HTC-DIGITAL-TC - Press TIME/ESCAPE for 5 sec till TS1 is displayed Press TEMP/ACCEPT display will show CLR.n Press up button till display shows CLR.y Press TEMP/ACCEPT BUTTON once, display will show DAY 1 Press up button till display shows DAY 9, then press TEMP/ACCEPT Display will now show ON,press TEMP/ACCEPT Press down button till hour shows 00, press TEMP/ACCEPT

Press up button till minutes show 01, press TEMP/ACCEPT Display will show OFF, press TEMP/ACCEPT Press up button till hour shows 23, Press TEMP/ACCEPT Press up button till minutes show 59, press TEMP/ACCEPT Display will now show DONE, press TIME/ESCAPE Controller will now be programmed for as close to 24hr operation as it can. It will go OFF between 23.59 PM and ON at 00.01 AM daily. How to program controller to accept an input from an adjustable sensor. Press TEMP/ACCEPT 5 (sec) till LOAD is displayed Press Up button till Rsp1 is displayed Press up button till 4.0 is displayed, display will show DONE Press TIME/ESCAPE button The controller is now programmed to accept an input from a Hevac adjustable sensor 4 degrees either side of setpoint Note a 3 rd wire will need to be run from the controller ( terminal R1 ) to the sensor ( terminal 1 ) Optimised Start ( OPT ) means the system is under control of the Optimised start feature. This feature causes the system to start at the latest possible time yet still achieve setpoint at normal occupancy time. To enable Optimised start ( OPT ) Press TIME/ESCAPE 5 (sec) till TS1 is displayed Press Up button till Opt is displayed Press the UP or Down button to unable (y) or disable (n) the Optimised start feature, display will show DONE Press TIME/ESCSAPE button

How to program HTC DIGITAL series controller to drive a slave controller ( HRC4-DIG, HRC4-DE-DIG etc. 5 ( sec ) till LOAD is displayed Press Up button till Yh Yc is displayed Press Up button till Yh. Y is displayed to accept db0.1 ( deadband ) Press TEMP/ACCEPT Press UP button till Pb = 5.0 ( proportional band ) to accept bar.n Press UP button till Yc.Y displayed to accept db0.1 ( deadband ) Press TEMP/ACCEPT Press UP button till Pb = 5.0 ( proportional band ) to accept bar.n DONE now appears, press TIME/ESCAPE button twice Note, the slave output is generated out of terminal YB on the HTC DIGITAL series controller which is then looped to termainal B on the HRC series slave relays. Important notes.

- Always make sure the controller is on the right time, date and day. See how to change date. - The controller needs an on & off time for it to initiate. Eg on at 8.00am off at 17.30pm. - The controller does not recognise 00.00 (12am) as on off time as it is a new day. Always make sure the off time is programmed in the same day as the on time. - If you want to run the HTC DIGITAL TC controller 24hrs then the on and off time MUST be programmed in the same day. Eg on at 00.01 am and off at 23.59pm. See 24Hrs 7 Day a week - There are shortcut or block on/off time programs Mon-Fri (Day 8), Mon-Sun (Day 9), each day will have the same on/off time. - On the HTC DIGITAL controller (non time clock version) be sure that relay 5 is programmed as Sr (Fan). Refer to Relay programming step in manual which is available at Hevac s website www.hevac.com.au. This is published in the hope if simplifying the process of programming the Hevac range of HTC DIGITAL controllers. Please feel free to call any of our friendly staff who can assist you further should you continue to have difficulties. Hevac Control Agencies Unit 7/54 Howleys Road Notting Hill Vic 3168 Phone : 03 9562 7888 Fax : 03 9562 7835 Email : sales@hevac.com.au www : www.hevac.com.au