XTM72 Exerciser Timer Module

Similar documents
XTM72E & F Real-Time Clock Modules

Overview: Specifications: Installation Instructions:

Two (2) Channel 365 Day 24 Hr. Timer/Controllers

SSPT724A Timer Quick Start Guide

24 Hour & 7 Day Digital Immersion Heater Timeswitch Article

INSTALLATION & OPERATING INSTRUCTIONS SINGLE/TWO CHANNEL 24HR/7 DAY TIMER. Cat No. TR671/TR672TOP

PT Two (2) Channel 365 Day 24 Hr. Timer/Controller

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

1 Overview. 2 Specifications. 3 Installation Instructions. HPT724 Programmable LCD Timer PN 52765:A 1/25/06 ECN Product Installation Document

talento 800 Series 365-Day One, Two and Four Circuit Electronic Time Controls Functional Description

TDDFM14 OWNER S MANUAL

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

Weekly Time Switch. Rated time Time setting range Time division 24 hrs x 7 days 00:00 to 23:59 1min

ULTRA-VANSTAT WIRELESS PROGRAMMABLE THERMOSTAT FOR CARAVANS

TU-8A. 8 Channel Digital Timer Unit. Programming Guide

USER & ENGINEER INSTRUCTION MANUAL

DCL Time Controller WTDCL. Universal Lighting Technologies is a subsidiary of Panasonic Electric Works Co., Ltd., a member of the Panasonic Group

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

Automatic Transfer Switch Control PLC Operator s Manual

Timer Modules. EL11 24 Hour Module EL17 7 Day Module. Installation & Operating Instructions

System pro M DT1-IK DT1-IK/24V DT1-IK/DCF DT2-IK 2CSM204275R0611 2CSM441017D5601 2CSM204285R0611 2CSM204295R0611 2CSM204325R0611

7 Day Digital Programmer 3 Channel Surface Mount

Timer Modules. MEU11 24 Hour Module, MEU17 7 Day Module (Without Housing)

Transfer Switch. OTECA (Spec A) OTECB (Spec A) OTECC (Spec A) OTECD (Spec A) Amperes. English Original Instructions (Issue 5)

7 Day Digital Programmer

7 Day Digital Light Switch with Optional Dusk Start

MODEL 2018 OPERATION MANUAL Firmware Version

Complete Part Number = MIL 72A or E Followed by Suffix Code and Voltage. Example: MIL 72A STuZ-24

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

Slimline Digital Electric Radiator. Step by Step Programming Guide

FW/S Digital time switch 2CDG120039R0011 D GB F I E NL. Installation and operating instructions FW/S DCF antenna GPS antenna SELV MENU

Programmable time switches Multiple function - daily/weekly

HS-509 VIBRATION TRIP MODULE

2 2 Relay outputs. M DIN W72 H7mm. LE7 Weekly/Yearly timer

ACT 10 Digital Keypad Operating & Installation Instructions This manual is found at

1 Channel Multi-Purpose Programmer User Instructions

Installation Instructions

FN:4181NX_M1.DOC MC4181NX MASTER CLOCK MC4181NX

CP027. User Operating Instructions. Two Channel Central Heating and Hot Water Programmer

TP7001 Range Electronic 7 Day Programmable Room Thermostat. Danfoss Heating. Installation Guide

Installation and Operation Manual. YMP Series Signal Programmer

TORK DGU100/DGUM100 7 DAY DIGITAL TIME SWITCH INSTALLATION AND OPERATING INSTRUCTIONS READ INSTRUCTIONS CAREFULLY BEFORE SETTING UNIT

Dial Ezy INSTRUCTION MANUAL N IRRIGATION CONTROLLER 4 or 6 Station Model SUITABLE FOR INDOOR USE ONLY OTHERWISE WARRANTY IS VOID

Digital Timer. 1 About your Slimline Digital Timer. 2 Mechanism Dimensions. Cat No. D817SLIMDP Instruction Manual

16 Amp Electronic 24 Hour/7 Day Time Controller

Lifestyle. Dual Channel Programmer. for heating AND hot water. Installation and User Instructions DUAL CHANNEL ISSA

Inserting the batteries. Basic settings of the remote control


ST9100C User Guide. Features

SINCE User Manual 7 DAY PROGRAMMABLE DIGITAL TIMER MODEL PS-100. The best solutions for automation and protection.

CP017 USER OPERATING INSTRUCTIONS. Single Channel Timeswitch

Philips LightMaster. KNX Timeclock Installation and Operation Manual

263 Series LED Bargraph Indicator and Controllers

Integrated Remote Commander

2 2 Relay outputs. M DIN W72 H7mm. LE7 Weekly/Yearly timer

ASTRONOMICAL CONTROL SYSTEM FOR LIGHTING SC2A-60. Basic Manual

FN:4181M5.DOC MC4181N SERIES MASTER CLOCKS MC4181N

SCS318. User Instructions. SCS318 comprising of SCS317 7 Day Wireless Programmable Room Thermostat and SSR303 Receiver

Model IQ4-PC User Manual Revision Date:

Comfort System T-32-P Universal Thermostat. Operation Manual

Simply clever! The digital DIN-rail time switches by Grässlin

SECURITRON PRIME TIME MODEL DT-7 INSTALLATION AND OPERATING INSTRUCTIONS

EXTERNAL. A digital version of this document is available to download and submit online at ADDRESS POST CODE

ServicePlus S17R Series 2 User Operating Instructions

Ambiflex MF620 USER GUIDE

Junior Max (JR Max ) Controller

Tech Support: Customer Service: General Tech Questions: Tech Docs:

MSC+ Controller. Operation Manual

INSTALLATION & USER GUIDE

Softwired Clock. Total Lighting Control. Catalog Number: RCLK8SWS DESCRIPTION FEATURES. Installation Instructions IMRCLK8SWS 1

Modular Lube Lubrication Systems System Controls

TORK DGS180 DIGITAL SIGNAL TIMER 24 HOUR WITH DAY OMIT

LP20. Installation & User Guide. Dual Channel Programmer. Part number 25039DR

DTS400B - DZS400BP 3/9/07 10:14 AM Page 1

LARGE DIGITAL LED REAL TIME CLOCKS

VISUALIZED DIGITAL TIMER

SCALE & WEIGHT DISPLAYS

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

7 DAY DIGITAL LIGHTSWITCH WITH OPTIONAL DUSK START INSTALLATION & OPERATING. Cat No. ZV700 INSTRUCTIONS

User Manual CC DC 24 V 5A. Universal Control Unit UC-1-E. General Information SET. Universal Control Unit UC-1 Of Central Lubrication PAUSE CONTACT

TC-1 Timeclock. Operating and Programming Instructions Thursday, 25 March Lighting Controls for the World we live in

Operation Guide 6022 ENGLISH

BE3-GPR GENERATOR PROTECTIVE RELAY

Operating instructions Electronic preset counter Type series 717

Innovative Air Systems ABN When Calling For Support Quote:.doc

MAKING MODERN LIVING POSSIBLE. TS715Si Electronic Single Channel Timeswitch with Service Interval Timer. Installation Guide.

INSTRUCTION MANUAL DLC400BP DIGITIAL LIGHTING CONTROLLER FOR TECHNICAL SUPPORT: USA

ChannelPlus H17XL Series 2 User Operating Instructions

1. Power supply 100, 110, 200, 220, 230 V AC (as designated), 50/60 Hz, single phase.

Waterline Room Controller - Type WLCT3

User s Guide. GreenKeeper 212 Features: Automatic Sprinkler System Controller

Operations. BCU Operator Display BMTW-SVU02C-EN

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell

210E - 210ECL ECL ECL

MATE3 Owner s Manual Addendum

User s Guide. ECx Features: Automatic Sprinkler System Timer

SINGLE ZONE CLIMATE ZONING SYSTEM. Technical Manual. Polyaire Pty Ltd

F90 Series (Rate Indicators / Controllers) INSTRUCTION MANUAL

CURRENT INJECTION RELAY TESTER CR-100. ( Code P60212 (770081) ) INSTRUCTIONS MANUAL ( M / 05A ) (c) CIRCUTOR S.A.

Master Time Clock MTC Users Manual

Transcription:

Capricorn Controls DA01XTM1-1 Data & Application Note Page 1 of 6 XTM72 Exerciser Timer Module Genset Controls - Timers - Monitors - Trips - Battery Charging - Spares & Accessories - Custom Products This D.C. powered, 7-Day, Real Time Clock was custom designed to compliment our range of Gen-Set controls to provide true 7-days On / 7-days Off switching ( flip/flop Mode) for use in Mutual Standby Systems. However, this versatile unit can be switched between normal or flip/flop operating modes, making it an ideal choice in a wide range of applications. Two small (DIP) switches (marked 1 & 2) are accessed through the top of the module, move Up for On and Down for Off. 1 - Select On (FF/1) for flip/flop operation on channel - 1 Select Off (FF/1) for normal operation on channel - 1 2 - Select On (BATT) to activate the real time clock (It will require programming - see overleaf). Select Off (BATT) to isolate the internal NiCad battery if the DC supply is removed for > 24 hrs. Key Points DIN 72mm square module with industry standard two-piece connector. Separate 12V and 24V DC inputs Single and Dual-Channel versions with separate SPCO volt-free contacts / channel. Contacts rated at 5 Amps / 230VAC (AC1) Flip-Flop operation for Mutal Standby applications (true 7-days On / 7-days Off). LCD digital real time 24 hr clock with day of week indicator. Internal NiCad battery provides over 150 hours reserve power to the clock. Multiple commands / day / channel. Self cancelling & Override. Model Channels Flip-Flop Mode Typical Applications XTM72A One (Ch-1) Fixed Mutual Standby XTM72B One (Ch-1) Optional General Purpose XTM72C Two Ch-1 optional + Ch-2 fixed Mutual Standby XTM72D Two Ch-1 optional + Ch-2 normal General Purpose Designed & manufactured in England by Capricorn Controls Telephone: +44 (0) 1295 272360 Fax: +44 (0) 1295 264766 E-mail: sales@capricorn-controls.com

Page 2 of 6 XTM72 A & B (Single Channel) Programming Time / Setting Day ( 3 = Wednesday) Day setting Clock button / Time display Program entry & Recall 10 : 29 1 2 3 4 5 6 7 1>7 d h m Prog Switching position of channel On or Off. Point indicates permanent function On or Off. Hours setting / Holiday program Minutes setting Channel selection and permanent function for: Channel 2 Channel 1 Starting Up: Switch internal battery On (through top of case). Press > d <, > m <, Clock & >C1< buttons simultaneously. All segments on display appear, time indication 0:00 --- Reset (total clearance). Setting the time of day Press and hold the clock button during the setting procedure. Set the arrow display to the relevant day by pressing > d <. Set the time by pressing > h < and > m <. Release the clock button the clock is now running as indicated by the flashing hyphen. Prog. Programme mode Up to 3 x On and 3 x Off operations per day (42 per week). Note: If the entry is interrupted (or finished) the display reverts to true time and automatic operation within 40 sec s. It may be necessary to start program entry again. Start of Program entry: Press >Prog. < button Setting of weekly program: The display shows --:-- --, two points are flashing on the right hand side. Select Channel 1 or Channel 2 by pressing >C1 < or >C2 < ( command by pressing once and command by pressing twice). Now the arrow above 1 (Monday) is flashing. If the command settings are for Monday, enter with >Prog.< button. Different or further days can be selected with the > d < button and entered with the >Prog.< button. If switching command is for Monday to Friday at the same time, all 5 arrows must be displayed on top of the figures 1-5. For daily settings all 7 arrows must be displayed. After the entry of the day(s) enter the required switching time with the buttons > h < and > m <. Enter displayed switching command by pressing the >Prog.< button. If program entry is finished, press Clock button. Attention: If a switching command 08:00 On is entered Recall settings Recall On and Off settings one after the other with >Prog.< button. After all occupied memory locations, a free one is offered. By pressing >Prog.< once more, E end of program is displayed. Afterwards press >Clock <. Prog. Change or clearance of a command Recall the command by pressing >Prog.< and change it by pressing > d <, > h < and > m < or clear the command indicated by simultaneously pressing > h < + > m <. Afterwards press clock. 1 47 Holiday Program Holiday program to interrupt the automatic program for 1 to 47 days. Press & hold the >h < button, a two digit figure is displayed, increment this by successive presses of the > C1 < button. The maximum possible number of holidays is 47. The first holiday is the following day, which means at 00:00 hours the two channels are switched off and the display shows H Off / Off. To finish the holiday period earlier or if not required at all, set the two-digit display to 00. Manual Override Press >C1< or >C2< to switch Channels 1 or 2 On or Off alternatively. The next counteracting automatic setting cancels the manual control. Permanent Control By simultaneously pressing Hand + > m <, the display will show a dot over the On or Off to indicate the permanent state. To change from one state to the other, again press Hand + > m < buttons together. To cancel the permanent over-ride press both the > m < + Hand buttons together, once or twice until the dot over the display British Summer Time Summer Time: + 1 hour, press > d < + > h < simultaneously Notes 1. Time display is in 24 hour format 2. Minimum switching interval is 1 minute 3. Switching accuracy is precise-to-the-second 4. Accuracy ± 1 sec / day at 20 C 5. If battery switched Off, reprogramming required. 6. > < highlights the setting buttons E. & O. E. The Proven Solution to Power Controls DA01XTM1-1

Capricorn Controls DA01XTM1-1 Data & Application Note Page 3 of 6 XTM72C & D (Dual Channel) Programming Time / Setting Day ( 3 = Wednesday) Day setting Clock button / Time display Program entry & Recall 10 : 29 1 2 3 4 5 6 7 d h m Prog C1 1 2 C2 Switching position of channels On or Off. Point indicates permanent function On or Off. Hours setting / Holiday program Minutes setting Channel selection and permanent function for: Channel 2 Channel 1 Starting Up: Switch internal battery On (through top of case). Press > d <, > m <, Clock & >C1< buttons simultaneously. All segments on display appear, time indication 0:00 --- Reset (total clearance). Setting the time of day Press and hold the clock button during the setting procedure. Set the arrow display to the relevant day by pressing > d <. Set the time by pressing > h < and > m <. Release the clock button the clock is now running as indicated by the flashing hyphen. Prog. Programme mode Weekly program with 24 free programme settings (on or off), with free block entry to one, several or all days of the week. Note: If the entry is interrupted (or finished) the display reverts to true time and automatic operation within 50 sec s. It may be necessary to start program entry again. Start of Program entry: Press >Prog. < button Setting of weekly program: The display shows --:-- --, two points are flashing on the right hand side. Select Channel 1 or Channel 2 by pressing >C1 < or >C2 < ( command by pressing once and command by pressing twice). Now the arrow above 1 (Monday) is flashing. If the command settings are for Monday, enter with >Prog.< button. Different or further days can be selected with the > d < button and entered with the >Prog.< button. If switching command is for Monday to Friday at the same time, all 5 arrows must be displayed on top of the figures 1-5. For daily settings all 7 arrows must be displayed. After the entry of the day(s) enter the required switching time with the buttons > h < and > m <. Enter displayed switching command by pressing the >Prog.< button. If program entry is finished, press Clock button. Attention: If a switching command 08:00 On is entered Recall settings Recall On and Off settings one after the other with >Prog.< button. After all occupied memory locations, a free one is offered. By pressing >Prog.< once more, E end of program is displayed. Afterwards press >Clock <. Prog. Change or clearance of a command Recall the command by pressing >Prog.< and change it by pressing > d <, > h < and > m < or clear the command indicated by simultaneously pressing > h < + > m <. Afterwards press clock. Manual Override Press >C1< or >C2< to switch Channels 1 or 2 On or Off alternatively. The next counteracting automatic setting cancels the manual control. Permanent control By simultaneously pressing >C1< + > m < for channel-1 or >C2< + > m < for channel-2, the following functions can be chosen one after the other: permanently On -- permanently Off Automatic operation. The points on the right of the display indicate the permanent function On or Off. British Summer Time Summer Time: + 1 hour, press > d < + > h < simultaneously Notes 7. Time display is in 24 hour format 8. Minimum switching interval is 1 minute 9. Switching accuracy is precise-to-the-second 10. Accuracy ± 1 sec / day at 20 C 11. If battery switched Off, reprogramming required. 12. > < highlights a setting buttons 13. describes a setting buttons Designed & manufactured in England by Capricorn Controls Telephone: +44 (0) 1295 272360 Fax: +44 (0) 1295 264766 E-mail: sales@capricorn-controls.com

Page 4 of 6 XTM72C DUAL MUTUAL STANDBY APPLICATI In this application the Duty Set selection is typically changed each week (7 days On - - 7 days Off). It may also be required that the system is disabled from running at certain times of the day or week. The XTM72C is designed to provide both of these requirements. Initial Set Up --- see programming information 1/ Switch Internal Battery On 2/ Reset the unit (total clearance of all programming) 3/ Set the time of day Channel 1 = When system is required to run [ie: Monday Friday, 6.00pm to 6.00am] 1/ Set Dip-Switch for Normal operation on channel 1 (NOT Flip-Flop mode) 2/ Program : Monday Off at 6.00am (06.00hrs) & On at 6.00pm (18.00hrs) 3/ Repeat this program for Tuesday, Wednesday & Thursday 4/ Program : Friday Off at 6.00am (06.00hrs) System Required to Run In Normal mode the relay changes state in line with the programmed times. Channel 2 = GenSet change-over [ie: Midnight Sunday, 7 Days On - - 7 Days Off] GenSet A GenSet B In Flip-Flop mode the relay changes state at each programmed transition from On to Off Thus, for the GenSets to changeover at mid-night each Sunday, program channel 2 On (for 1 hour) from Sat 11.00 pm (23.00 hrs) to Sat 12.00 pm (24.00 hrs). The duration of this On period is not important (and could be as low as 1 minute) but an hour is easier to program. E. & O. E. The Proven Solution to Power Controls DA01XTM1-1

Capricorn Controls DA01XTM1-1 Data & Application Note Page 5 of 6 XTM72D DUAL MUTUAL STANDBY APPLICATI In this application the Duty Set selection is typically changed each week (7 days On - - 7 days Off). It may also be required that the system is disabled from running at certain times of the day or week. The XTM72D is designed to provide both of these requirements. Initial Set Up --- see programming information 1/ Switch Internal Battery On 2/ Reset the unit (total clearance of all programming) 3/ Set the time of day Channel 1 = When system is required to run [ie: Monday Friday, 6.00pm to 6.00am] 1/ Set Dip-Switch for Normal operation on channel 1 (NOT Flip-Flop mode) 2/ Program : Monday Off at 6.00am (06.00hrs) & On at 6.00pm (18.00hrs) 3/ Repeat this program on Tuesday, Wednesday & Thursday. 4/ Program : Friday Off at 6.00am (06.00hrs) System Required to Run In Normal mode the relay changes state in line with the programmed times. Channel 2 = GenSet change-over [ie: Midnight Sunday, 7 Days On - - 7 Days Off] GenSet A GenSet B In Flip-Flop mode the relay changes state at each programmed transition from On to Off Thus, for the GenSets to changeover at mid-night each Sunday, program channel 2 On (for 1 hour) from Sun 12.00 pm (24.00 hrs) to Mon 01.00 am (01.00 hrs). The duration of this On period is not important (and could be as low as 1 minute) but an hour is recommended. Designed & manufactured in England by Capricorn Controls Telephone: +44 (0) 1295 272360 Fax: +44 (0) 1295 264766 E-mail: sales@capricorn-controls.com

Page 6 of 6 Terminations DIP Switches Common -Ve 1 (do not use) 2 +24Vdc Supply 3 RL1 N/O 4 RL1 C/O 5 RL1 N/C 6 RL2 N/O 7 RL2 C/O 8 RL2 N/C 9 +12Vdc Supply 10 Relay 1 Flip/Flop Operation Battery Back-Up On S1 S2 Note : 1/ Channel 2 (Relay 2) on the dual channel XTM72C operates in Flip-Flop mode only. 2/ Neither channels on the dual channel XTM72D operates in Flip-Flop mode. 3/ Ensure that the internal battery is switched Off if the unit is disconnected from the DC supply (12 or 24Vdc) for more that 24 hours. However, when the internal battery is switched On again the clock must be reprogrammed. Dimensions All dimensions in mm. 72 Panel cut-out = 68 x 68 Not to Scale 72 85 Note : If specific information or a replacement unit is required please ensure that the Serial Number of the original unit is quoted. CAPRICORN CTROLS LIMITED INDUSTRIAL ELECTRIC ENGINEERS SPECIALIST CTROLS FOR ENGINE APPLICATIS Thorpe Close, Banbury, Oxon., OX16 4SW. England Tel: +44 (0) 1295 272360 Fax: +44 (0) 1295 264766 E-mail: sales@capricorn-controls.com Web: www.capricorn-controls.com Keystart, Remote Start, Start-on-Demand, Mains Failure, Mutual Standby & Multi-set Controllers. Annunciators and Lamp Modules. Voltage, Current, Frequency, Speed, and Temperature Monitors. Timers. Transport Refrigeration Spares. Batteries, Battery Chargers and Power Supplies. Spares and Accessories. Customised Products and Bespoke Designs. E. & O. E. The Proven Solution to Power Controls DA01XTM1-1