Luminaire installation box Surface-mounted box Ceiling installation box

Similar documents
Fig. 1. Fig. 3. Ordering data. Fig. Mounting

Ordering data. Type Inputs Outputs Dimming switch Motion sensor DSI signal2 Digital control line DSI Control output per physical output (devices)

PHASED OUT. Control module with 3 channels/single, twin push to make switches/ presence detector/modulardim power supply

Emergency lighting units EM powerled

Tri-level Control HF Sensor

Dimming actuators GDA-4K KNX GDA-8K KNX

Emergency lighting units EM powerled

LED control gear Compact dimming. Uconverter LCAI 2x38 W 0500 K013 one4all ECO series. Ordering data

A digital version of this document is available to download and submit online at ADDRESS POST CODE

2-output DALI controller

Dimming actuators of the FIX series DM 4-2 T, DM 8-2 T

Operating instructions III / 2004

CAMTO LTD. Arc detecting system DC/AC

Mosaic TM Dimmer 3 x 1000 W

Projector Lift. User Guide INSTALLATION OPERATION SETUP PROGRAM IR REMOTE FACTORY RESET

ArteorTM Dimmer 3 x 1000 W / /60

Professional-Practice

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

Installation & Operations Manual

4.0 Description. 2-channel operation D1 and D2 rated at 200 VA each. 1-channel operation D1 rated at 400 VA (see connection chap. 6.

Motion detector theluxa P300 KNX Motion detector theluxa P300 KNX

STX Stairs lighting controller.

21 Channel Light Show PWM LED Controller with Remote Control

15 Series - Dimmer

LED Driver Compact dimming

SINGLE ZONE CLIMATE ZONING SYSTEM. Technical Manual. Polyaire Pty Ltd

luxcontrol lighting control system DALI actuator DALI PCD one4all G2 Leading-edge/trailing-edge phase dimmer

Technical data. General specifications. 60 ma Power consumption P 0. 1 W Time delay before availability t v. 120 ms Interface. Protocol IO-Link V1.

Gamma instabus. Technical product information

Dimensions. Model Number. Electrical connection. Features. Pinout Product information. Indicators/operating means. LGS25 Serie.

SHUTTLE WITH INFRA-RED DETECTION SAS2-IR

LED DRIVERS. LQC4D-V1 4 channels. User Manual FEATURES

Sensor module. Safety instructions. Function Correct use. Product characteristics. Structure of the device. Operation. Ref.No.

10 SERIES. Light dependent relays A

User Manual CC DC 24 V 5A. Universal Control Unit UC-1-E. General Information SET. Universal Control Unit UC-1 Of Central Lubrication PAUSE CONTACT

Dimmers SЕRIES. Kitchen light control. Bedroom light control. Living room light control

luxcontrol lighting control system DALI actuator DALI PCD one4all G2 Leading-edge/trailing-edge phase dimmer

Instruction manual. DALI Gateway art Installation manual

EXTERNAL. A digital version of this document is available to download and submit online at ADDRESS POST CODE

HS-509 VIBRATION TRIP MODULE

LEVEL CROSSING MODULE FOR LED SIGNALS LCS2

CSM Color sensors. Color sensors for the detection of a single color in restricted space conditions

2CKA001473B KNX Technical Reference Manual ABB i-bus KNX. KNX LED dimmer Constant voltage 4gang with power adaptor 6155/40-500

Technical data. General specifications. Indicators/operating means

Electrical connection

LED Driver Linear / area dimming. Driver LCAI 38/75W TW lp Tunable White

LED control gear Compact fixed output. Uconverter LCI 55 W 1400 ma O010 TOP series Ø4,4. Ordering data

High Resolution Multicolor Contrast Scanner. Dimensioned drawing

PHASED OUT. LED control gear Compact fixed output. Driver LC 40W 900mA fixc C SNC China Domestic ESSENCE series

8000 Plus Series Safety Light Curtain Installation Sheet ( CD206A/ CD206B )

HID control gear Electronic

Mains Supply. 2-wire mains-rated, 0.5 mm² to 1.5 mm² Max. length 300 m (with 1.5 mm² cable). Example: Belden 8471.

PHASED OUT. HID control gear Electronic. PCIS, PCI, PCS outdoor DIM chronostep PCI outdoor

TUC: Universal thermostat

INSTALLATION & USER GUIDE

Application manual. KNX movement detector for wall flush mount EK-SM2-TP

Online data sheet SGS4-S108P3PS2W03 SLG SWITCHING AUTOMATION LIGHT GRIDS

Aspect 2 Circuit Digital Scene Control

OUT. HID control gear Electronic. PCIS, PCI, PCS outdoor DIM B011 PCI outdoor

GreenParking. Commissioning guide. GreenParking

LED Driver Compact fixed output

LED Driver Compact fixed output

LED Driver Linear / area fixed output

Operating Instructions

BLOCK OCCUPANCY DETECTOR

RADIO RECEIVER RGBW CONTROLLING LED STRIP COMMON ANODE

LED Driver Compact fixed output

System 2000 System 2000 HLK relay insert. 1 Safety instructions. 2 Device components. 3 Function. Order No. : Operating instructions

T5, T8, TC-L. PC T5 PRO lp W V 50/60/0 Hz, HO. Electronic ballasts Linear lamps T5, T8 and compact lamps TC-L

45 mm : all channels. Output indicator Yellow LED System status indicator Light source Infrared (880 nm) Opening angle +/ 4 Emission angle +/ 5

TP7001 Range Electronic 7 Day Programmable Room Thermostat. Danfoss Heating. Installation Guide

Channel Controller for Light Show with Remote Control. HomLiCon RCL164R

HID control gear Electronic. PCIS, PCS outdoor FOX B011 PCI outdoor. Ordering data. Circuit power1. tc/ta for 60,000 h For luminaires with 1 lamp

LINK-RAY TM MODULATORS FOR CONSTANT- VOLTAGE. LinkRay Modulators 12 V / 24 V Constant-voltage Applications MODULATORS

LED Driver Compact dimming

LED Driver Compact dimming

HYL-035D0850G103. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

SPECIFICATION NO Model 207 Automatic GTAW Welding System

Automatic Transfer Switch Control PLC Operator s Manual

As versatile as your requirements.

Tectiv 220 Instructions for use

MaxLite LED Wall Packs (Cutoff & Standard)

General FAQs Status as of: 22/10/2018

LED Driver Constant voltage

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

Catalogue Ignitors and power switches for HID

MICROMASTER Encoder Module

TDEPD. Field-Programmable Pressure Switch/Transducer with Integrated LED Display. Programming Sequence Manual

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

RGB-3400-X RGB SEQUENCER / 3-CHANNEL UNIVERSAL LED DIMMER

Location. Electrical. Loads. 2-wire mains-rated, 0.5 mm² to 1.5 mm² Max. length: 300 m (with 1.5 mm² cable). Example: Belden 8471.

IP Roombox. Hotel Room Management

LED Driver Compact dimming

16 Amp Electronic 24 Hour/7 Day Time Controller

B65 LED Emergency lighting units with LEDs

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV

LED Driver Compact dimming

SHOWLINE SL NITRO 510 LED STROBE LUMINAIRE SPECIFICATIONS.

AK-PVE4 Operating Instructions. Measuring of norm signals in wall-type units. Performance:

Product information. Front-door station series with video for surface-mount

Transcription:

-Smart PTM Ambient light sensor and motion detector for constant lighting control uminaire installation box Surface-mounted box Ceiling installation box Overview: -SMART PTM i is an ambient light sensor, with a motion detector and infra-red input. It is a digital control module for controlling up to or 5 ballasts (see table). With the aid of a standard switch it provides a user-friendly way of switching the lights on and off and fading them up and down. As an option, the -SMART PTM can be combined with the -SMART Controller infra-red control. With the -SMART Programmer various device parameters can be changed to suit requirements and monitor the current values of the module. Packaging: uminaire installation box: 10 pieces/box Surface-mounted box: single packaging or 10 single packaging/box Ceiling installation box: single packaging or 10 single packaging/box Developed in accordance with: E 55015 E 60669--1 E 61000-- E 61000-- E 617--11 E 6157 E 686-101 Type Smart PTM fitted in luminaire Smart PTM surface-mounted Smart PTM recessed into ceiling Article number: 8658588 8658589 8658587 Power supply: Voltage V 0 0 0 0 0 0 Frequenzy Hz 50 50 50 Max. load W 1.7 1.7.9 Standby load W 1.5 1.5 1, Input: Push to make switches - single single singel max. Tasterleitungslänge m 100 100 100 Output: Digital control signal - 1 1 1 Max. cable length with 1.5 mm² m 50 50 50 Max. number of /TE oneall/pcd 5 Ambient conditions: Operating temperature t a C 0... 60 0... 60 0... 60 Storage temperature C -5... 60-5... 60-5... 60 Type of protection IP0 IP0 IP0

Dimensional drawings: uminaire installation box: Surface-mounted box: 6,9 Ø 60 8 6,8 6 Ø 60, 55 Ø 86 Ø 5,6 Ceiling installation box: 50 Ø 86 5 6 19 50 1 Ø 75 Wiring diagram for -SMART PTM (luminaire installation and surface-mounted boxes) * -SMART PTM 7 D / DA max. /TE oneall/pcd... 7 D / DA * must be the same phase as for Wiring diagram for -SMART PTM (ceiling installation box) * -SMART PTM 7 D / DA max. 5 /TE oneall/pcd... 7 D / DA Sensor * must be the same phase as for

Switch: -SMART PTM has an input terminal for an external switch. Any number of switches can be connected in parallel to the terminal. Short press (> 50 600 ms): O/OFF ong press (> 600 ms): Dim up/down A change in the light value deactivates lighting regulation only temporarily. As soon as the luminaire has been automatically switched on again (motion detection) or manually switched off and on again, regulation is activated again. x short press: The overwritten setpoint light value is stored (luminaire acknowledges by flashing twice) Installation: is not SEV. The installation instructions for low voltage therefore apply. The maximum cable length between the external switch and -SMART PTM is 100 m. The cable between he ceiling sensor and the base module must not be extended. Cable types and cable cross-sections: Solid wire with a cable cross-section of 0.5 mm² to 1.5 mm². wire preparation: 0.5 1.5 9 mm ±1 Installation: uminaire installation box: Ceiling installation box: Ø 5 mm Ø 75 mm min. 100

Motion detector: Motion detection Ambient light control: ight level recognition area h * m d1 m d m 1.7. 1.6.0.0 1.9 h 90..6..5 5.0. h 50.7 5..5.0 6.0.8.5 7.0. d1.0 8.0.7 * The recommended maximum room height is m. d Calculation of the diameter: d = tan(0,5 a) h The following operating modes can be set for the motion detector via the - Smart Programmer: The following operating modes can be set for lighting control via the - Smart Programmer: Active Off Only ever Off Inactive The light is switched on or off automatically depending on whether or not there is a person in the room. The motion detector only switches the connected lighting off. The luminaires are switched on manually via the connected external switch or infra-red control. If it has not detected any movement the sensor dims to the second light value parameter and remains at this value The motion sensor is deactivated. The light must be switched on or off manually. Switch-off delay: This is the time after which the lighting is switched off if no movement is detected. It can be set via the time delay parameter. Second light value: On the -Smart PTM you can set whether the light is to be switched off after the switch-off delay or dimmed to the second light value. The light value and the dwell time (how long the value is held) can be set via the when vacant and sec. level parameters. Manual-off delay: If the system is switched off manually via the switch or remote control the motion sensor is deactivated. At the end of this delay if motion has not been detected the motion sensor is activated again. If the sensor detects motion during the Manual Off delay, the time will be reset to the start. Active Inactive Constant light control is active. Constant light control is deactivated. The lighting is switched on at 100%. The value is set with the light-level parameter. If the value is set to max then lighting control is deactivated. For all other values lighting control is active. Setpoint adjustment: -SMART Controller: Pressing the Set button stores the current light value as a new setpoint. -SMART Programmer: Via the light-level parameter External switch: Briefly pressing the switch twice stores the current light value as a new setpoint. Bright-out: If the nominal illuminance (e.g. 500 lux) is exceeded for 10 minutes by more than 150 % (e.g. 750 lux), the lighting is switched off even if motion is detected. The lighting is switched on again when the measured light value falls below the setpoint. This function can be deactivated via the -SMART Programmer.

User-definable parameters: -SMART PTM have the following user-definable parameters: The values shown in bold are the factory default settings. Parameter light-level time delay when vacant Range Factory setting 1-100/max/man 70 0 s-60 min/con 0 off low (1 m-cont) sec. level 1-100 1 P.I.R active inactive off only bright-out Power up hold overwrite yes o on off on off Description ight level in steps from 1 to 100. The max option lets you set the units at maximum output. ( 55) man indicates whether the control value has been overwritten with the SET functions of the SMART controller. Delay before switching off after the last detection of movement. The options are as follows: 0 seconds, 1,,, 5, 10, 15, 0, 0, 5 and 60 minutes, and con (continuous) The off setting causes the luminaire to switch off at the end of the switch-off delay. The low setting causes the luminaire to fade to the sec. evel parameter and switch off only at the end of the second delay set. The options are as follows: off, 1,,, 5, 10, 15, 0, 0, 5 and 60 minutes, and continuous ( never OFF function) Second light value to which the system fades at the end of the switch-off delay. (In connection with the when vacant parameter ) The active setting switches the light on or off automatically depending on whether or not there is someone in the room. With the inactive setting the -SMART, in combination with time delay continuous, can be used only for controlling the light level. In the off only setting the light has to be switched on manually (switch, remote control) but is switched off by the motion sensor. The yes setting switches the light off as soon as the light value exceeds 150% of the control value for more than 10 minutes. If the actual value falls below 100% the light is switched on again. In the no setting the luminaires remain at the minimum light value. In the on setting the luminaire switches on after a power outage. In the off setting the luminaire does not switch on after a power outage. After 15 seconds the motion sensor is active again. In the off setting the -SMART is reset to automatic mode when the control value is overwritten with the SMART controller or with the switch after an on/off cycle initiated by a movement interruption (end of delay time). If on is selected the luminaire switches on again with the overwritten value (manual light value) unless the overwritten value was an OFF command, in which case -SMART returns to automatic mode so people do not enter a dark room. Parameter 1 light - level time - delay sec. level when recent Description see parameterlist light level 1 motion in the room delay time

Accessories for -SMART PTM -SMART Controller: Infrared remote control. Article number: 86519 Power supply: x R0/AAA/1,5 V standard or rechargeable batteries The IR smartcontroller is used for operating a - SMART PTM luminaire group. The remote control offers the following functions: Switching the lighting on and off Fading the lighting up and down Activating lighting regulation (Automatic) Setting the setpoint for lighting regulation Fading up or down temporarily deactivates lighting regulation and the set dimming value is retained. -Smart-Programmer: Infrared programming unit Article number: 86755 Power supply: x R6/AA/1,5 V standard or rechargeable batteries The optional -SMART Programmer enables parameter settings to be made on the sensor. It also enables current values to be controlled and the stored parameters of the sensor to be read. -SMART PTM has a more extensive parameter list than -SMART. To set these new parameters -SMART-Programmer Version.00 or higher is needed. For more information on programming the parameters please refer to the operating instructions for the -SMART Programmer.