TUC: Universal thermostat

Similar documents
Max. temp. of sensor C. Capillary tube mm. Switching difference K. Sensor cartridge mm

Panel-Mounted Thermostat

JUMO extherm-at Type , explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

Panel-mounting thermostats, type series EM

JUMO extherm-at Type , Explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

Panel-mounting Thermostats EM Series

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

Surface-mounting thermostats ATH series

Mechanical flow switch for On/Off control

Surface-mounting thermostat, type series ATH.-SE

Surface-mounting thermostat, type series ATH.-SE to monitor seagoing vessel equipment

Bimetal Temperature Switch

SAUTER flexotron RDT405 Manual

Heating thermostat Series AMHs B Operating Instructions 11.06/

Single Point Flow Monitor SW118 SW119

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

LMP 305. Slimline Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

PROPORTIONAL VALVES Sentronic plus

Level Measurement silometer FMC 420, FMC 423

estat20 Electronic Humidistat with remote sensor head Technical data Electrical data Humidity Temperature +125 C

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

SERIES x5. Nickel-plated brass Connection 1) PUR cable type 1 Degree of protection. IP 67 Mounting. Embeddable Max. switching frequency

Luminaire installation box Surface-mounted box Ceiling installation box

technical data (according to IEC ) Degree of protection IP 67 Max. ripple content 15 % U B / 20 % U B (amplifier) No-load supply current

Inductive sensor NI10-M18-Y1X-H1141

Inductive sensor With analog output BI15-M30-LI-EXI

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

SHARP Plasma inverter cutting range

Gear Pump Units For single-line centralized lubrication systems

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

CITOCUT Plasma inverter cutting range

PRESTOJET Plasma inverter cutting range

Inductive sensor BI1.5-EG08K-Y1

Inductive sensor NI3-EG08K-Y1-H1341

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

Product Data Sheet

Level Switch. LS Ex KS Ex RS Ex. Manual. AQ Elteknik AB

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area

DMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.

DMP 331Pi. Precision. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

Magnetic Stirrers Magnetic Stirr

7 Lighting Technology

Lt DELTA USA, Inc

1 Output 1 operation. 3 Pressure unit display. 4 Main display Large 4-character LCD display. 5 Sub-display Small 4-character LCD display.

DLP200M 2 Relay Module for Heating and Cooling Plants

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

Operating instructions

Modular Lube Lubrication Systems System Controls

ALLEN BRADLEY TIMING RELAY

Electrical connection

- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request

Coils for solenoid valves

Type Contact form Model Ag (Au clad) Standard DPDT G6A-274P-ST-US Low-sensitivity DPDT G6A-274P-ST40-US

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

SINGLE ZONE CLIMATE ZONING SYSTEM. Technical Manual. Polyaire Pty Ltd

CONTACT-DUO-PROFILE. Contact-Duo-Profile overview

Dewatering. Series description Wilo-Drain STS 65. Submersible sewage pump

LPUM - Local Power Unit General. Product Data Sheet January 2013 SD E06

Cooling systems for ORBIMAT

1 Inductive proximity switches. 5 Connecting cables. Highlights: New:

45 mm : all channels. Output indicator Yellow LED System status indicator Light source Infrared (880 nm) Opening angle +/ 4 Emission angle +/ 5

istep STEPPER MOTOR PUMP

Safety Light Curtain Orion1 Extended

APPLICATIONS. Automatic warehouse. Trasportation lines

SERIES 400 SERIES 620

CITOCUT Plasma inverter cutting range

A V 50Hz / V 60Hz

Hygrotest 600. Instruction manual WH / WHT -20/+70 C DH / DHT -20/+70 C / DHT -20/+120 C PHT -20/+70 C / PHT -20/+120 C

3 Cleaning. 4 Technical data

Online data sheet SGS4-S108P3PS2W03 SLG SWITCHING AUTOMATION LIGHT GRIDS

LMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

IMPAC Infrared Thermometers

llen-bradley 194R-HM4-NFPA3

Electrical connection

Roof-mounted Blue e+ cooling unit Integration solution VX25

Küba comfort DP. Draught-free ventilation and extremely quiet operation

The full range of performance

Description. Specifications and Ordering Information 1900/27 Vibration Monitor

Absolute Encoders Multiturn

DS 210. Electronic Pressure Switch. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

Series CT7N Bimetallic Overload Relays

263 Series LED Bargraph Indicator and Controllers

Pendant Light Fitting IEC Series 6470/2

Signet 2250 Hydrostatic Level Sensor

Intelligent compressor solutions. EFC, EFCe Systems Electronic Frequency Control EFC. EFCe

OPERATIONS MANUAL. ba76140e01 02/2013 CONDUCTIVITY CELL FOR ULTRAPURE WATER

Liquid Level Sensor AKS 4100U

ZN-PD. Smallest Air Particle Sensor in the Industry for In-line Measurement. Air Particle Sensor. Features

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43

Datasheet - SRB-E-201ST

Series description: Wilo-Drain VC

APPLICATIONS. Automatic warehouse. Trasportation lines

(1) (2) (3) Bedienungs- und Montageanleitung. Safety instructions. Structure of the device

MID-EX-E. Figure: MID-EX-E*010* ka052000en; Rev. 2.3 J

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:

Liquid Level Sensor Type AKS 4100U

2-output DALI controller

Transcription:

Product data sheet 3.1 21.700 TUC: Universal thermostat How energy efficiency is improved Control, monitoring and limiting according to needs and with no auxiliary energy. Features Regulates and monitors the temperature of liquids in baths, containers, pipes and ducts Variants as temperature monitors (), safety temperature monitors (S), temperature limiters (TB) or safety temperature limiters (STB) Thermostat with remote sensor Clamp-on thermostat Capillary tube thermostat with or without thermowell Double thermostat, e.g. as and STB Certified as per EN 14597 (TUC207F003 and TUC407F001, TUC407F002) As per PED 2014/68/EU classified as cat. IV (TUC207F003, TUC407F001 and TUC407F002) The shift in the change-over point is minimised due to the temperature compensation. Thermowell 100 mm supplied (max. 12 bar) TUC*0*F00* Technical data, S Power supply Max. load Min. load Terminal 1-2 230 V~, 10 (2.5) A (on the normallyclosed contact) Terminal 1-4 230 V~, 2 (0.4) A Terminals 1-2, 1-4 24V =/~, 100 ma Adjustment point For ta 22 C Effect of temperature at instrument head Approx. -0.1...-0.2 K/K Parameters T TB, STB Xsd Time constant without thermowell Xs Time constant with thermowell (LW 7) < 45 s (water) < 60 s (oil) < 120 s (air) Ambient conditions 0...70 C Storage and transport temperature -25...80 C 4 2 1 Construction Connection terminals Plug-in connectors Cable cross-section 0.75...2.5 mm2 Sensor cartridge Ø 6.5 mm Housing Two sections, lower section black, upper section yellow, including inspection window Housing material PA, ABS, PMMA Weight 0.2 kg Type of protection IP54 (EN 60529) Protection class I (EN 60730) Test marks TÜV ID: 0000046121 (EN 14597) B01571 Ambient temperature TUC407F001 TUC407F002 Standards and directives TUC207F003 Overview of types Type Setting range Type Switching difference Capillary tube length Thermowell Max. sensor temp. TUC101F003-10...50 C Approx. 4.2 K 1.6 m 100 mm, brass 140 C TUC102F001 5...30 C TUC105F001 15...95 C TUC106F001 40...120 C TUC107F001 50...130 C Right of amendment reserved 2017 Fr. Sauter AG 1/6

Type Setting range Type Switching difference Capillary tube length Thermowell TUC108F001 80...160 C 100 mm, stainless steel Max. sensor temp. 200 C TUC207F003 70...130 C S Approx. 10 K 1.6 m 100 mm, brass 160 C TUC303F001 15...60 C TB 20 K TUC307F001 50...130 C TB 20 K TUC407F001 95...130 C STB 20 K 100 mm, brass 160 C TUC407F002 95...130 C STB 20 K 150 mm, brass 160 C A A With TUC407F001, TUC407F002 and TUC207F003, only use the supplied thermowells or stainless-steel thermowells (part nos.: 0393022*** or 0392022***). TUC108 with adapter for temperature reduction. Accessories Type Description 0300360008 Retaining holder for cable temperature sensor or capillary tube with 0392022*** (LW 7) or LW 15 (10 pcs) 0300360009 Holder for sensor cartridge 0300360010 Retaining strap for fitting onto pipes for a pipe diameter of 15-100 mm 0300360011 Mounting plate for double thermostats 0300360012 Sensor support spiral for fitting in ventilation duct 0300360013 Duct/wall mounting bracket Description of operation This universal thermostat regulates and monitors the temperature of liquids or air in baths, containers, pipes and ducts. Definitions and functions Depending on the temperature, the single-pole change-over switch is activated. Setpoint (X s ) The setpoint (X s ), which can be adjusted, corresponds to the upper change-over point. Switching difference (X sd ) The switching difference (X sd ) is equal to the difference between the upper and lower change-over point. It is set to a fixed value for all TUC models (see type description). Temperature monitor () The temperature setpoint can only be adjusted with the aid of a tool. The set temperature is switched on and off automatically. Safety temperature monitor (S) The S has the same functions as the, but the contact switches to the safe side if a capillary tube is broken. Temperature limiter (TB) The temperature setpoint can only be adjusted with the aid of a tool. The reset is initiated by pressing the RESET button with a tool once the temperature has decreased by the minimum switching difference. Safety temperature limiter (STB) The STB has the same functions as the TB, but the contact switches to the safe side if a capillary tube is broken. As it is classified as PED 2014/68/EU cat. IV, the STB is suitable for safety applications. Two universal housings can be connected to each other using accessory 0300360011. In this way, it is easy to create a monitor-limiter double thermostat. 2/6 Right of amendment reserved 2017 Fr. Sauter AG

Intended use This product is only suitable for the purpose intended by the manufacturer, as described in the Description of operation section. All related product regulations must also be adhered to. Changing or converting the product is not admissible. Technical appendix Switching point accuracy At the adjustment point ±6K S, TB, STB At the adjustment point 0/-9 K B03772 RC circuitry for inductive load For the optimum RC circuitry, see the information from manufacturers of gates, relays, etc. If this is not available, the inductive load can be reduced by applying the following rule of thumb: Capacity of the RC circuitry (µf) equal to or greater than the operating current (A) Resistance of the RC circuitry (Ω) approx. the same as the resistance of the coil (Ω) Materials Material Housing base Housing cover Inspection window Thermowell (LW 7) A PA ABS PMMA Brass (CuZn) Stainless steel (CrNi) It is the responsibility of the operating company to check and verify that the thermowell materials are compatible with the fluids in which they are submerged. Sensor medium Up to 160 C Silicone oil Based on the available information, when used as intended, the product is not dangerous as per Directive 67/548/EEC. Disposal When disposing of the product, observe the currently applicable local laws. More information on materials can be found in the Declaration on materials and the environment for this product. Right of amendment reserved 2017 Fr. Sauter AG 3/6

Connection diagram TUC10*F00*, TUC30*F001 TUC*07*F00* ) Note Use temperature-resistant cables (T > 90 C) Dimension drawing 150 120 53 15 mm 58* G 1/2 *) STB: 63 mm 100/150 mm ᴓ 9 mm 4/6 Right of amendment reserved 2017 Fr. Sauter AG

2 Product data sheet 3.1 21.700 Accessories 0300360011 0300360012 53 32 25 6 70 94,1 41,7 t=2 M4 118 106 200 16 Right of amendment reserved 2017 Fr. Sauter AG 5/6

0300360013 25 0300360009 6 30 12,5 14 60 72,5 0300360008 20 mm 20 mm Fr. Sauter AG Im Surinam 55 CH-4016 Basel Tel. +41 61-695 55 55 www.sauter-controls.com 6/6 Right of amendment reserved 2017 Fr. Sauter AG