Cable ISOBUS Active Termination

Similar documents
GENUINE PARTS CAUTION

AUDIO ROOF KIT P/N , , APPLICATION BEFORE YOU BEGIN KIT CONTENTS. Instr Rev Page 1 of 6

GENUINE PARTS. SIRIUS Under Glass Antenna Kit

Assembly instructions

DLMP Installation Instructions

GENUINE PARTS SATELLITE RADIO INSTALLATION INSTRUCTIONS. 1. DESCRIPTION: Satellite Radio System 2. APPLICATION: Frontier (2006~)

OWNER'S MANUAL SIGNAL COMMANDER

Crane Systems Extension Reel Cable Guide Hardware Kit

DLMP-45/45R Installation Instructions

NewScope-7A Operating Manual

GENUINE PARTS ! CAUTION

Satellite Dish Installation Manual (Ver. 2) 1

Cabling and Completing Assembly of the Cisco TelePresence System 1000

Industrial Monitor Update Kit

Site Installation Model MP-8433

Site Installation Model MP-8424

IP-LINX Fiber :: X-XXXX

TV55. Owner s Manual. Indoor/Outdoor Amplified TV Antenna

HCS - HES Cabling Systems

OWNER'S MANUAL SIGNAL COMMANDER

Cellular Signal Booster

PC-250. SMD Taped Parts Counter Operator s Manual. ISO 9001:2008 Certified. V-TEK, Incorporated 751 Summit Avenue Mankato, MN USA

OWNER'S MANUAL SIGNAL COMMANDER

INSTALLATION MANUAL FOR THE TIMING LIGHT

Vibratory Deck Sieves 15 in. (380 mm)

Automatic Connector MHV Connectors MHV Introduction MHV series connectors Contents Polarized mating interfaces Anti-Rock mating interfaces

Snail Fence InteleCell Deployment Guide

INSTALLATION MANUAL. Agra-GPS Claas-JD Bridge for Claas- Lexion combines

24-Fiber LANLINXS (Model # ) 48-Fiber LANLINXS (Model # ) User Manual

IP-LINX. Installation Guide

Assembling and Mounting the Presentation Display, Speakers, Speaker Screens, and Table Door

INSTALLATION INSTRUCTIONS FOR

TV Lift System Model CL-65 Installation Instructions

3M Fiber Optic Splice Closure 2178-XL & 2178-XL/FR

3M Distribution Box (DDB)

A449-6S 70 CENTIMETER FM YAGI ANTENNA MHz

WINEGARD INSTALLATION MANUAL. Model GM Carryout Ladder Mount for mounting pipes with outer diameters between 1 to 1-1/8

3. Electronics and MMU2 unit assembly

1.8 METER SERIES 1183 Az/El MOUNT ANTENNA SYSTEM

HN Connectors. Automatic Connector. Introduction. Contents. 631/ FAX 631/

How To: Replace the stock Antenna with a CB Antenna A CFans Members Mod Project by coyote

Original BMW Accessory. Installation Instructions.

HQ Electromagnetic Channel Locks

CONNECTING THE FUTURE 19" LINXS LIGHTWAVE INTEGRATED CROSS-CONNECT SYSTEM USER MANUAL


Fixed Audio Output for the K2 Don Wilhelm (W3FPR) & Tom Hammond (NØSS) v August 2009

In-Ceiling Electric Motorized Front Projection Screen Evanesce Series. User s Guide

CC-M12 and CC-M48 Series Controllers Model No. CC-M12-M48

Installation Note. Agilent 89441A Option AYC Installation Kit

3M Fiber Optic Splice Closure 2178-XL & 2178-XL/FR 3M Cable Addition Kit 2181-XL and 2181-XL/FR

A CENTIMETER FM YAGI ANTENNA MHz

TracVision R6DX Installation Guide

READ ME FIRST. Touchstone TV Lift

TECHNICAL GUIDE. TOUGH GUN ThruArm G2 Series Robotic MIG Guns for FANUC Robots 100iC, 100iC-6L, 120iC, 120iC-10L INSTALLATION MAINTENANCE

HD Flex Patch Panel. ASSEMBLY VIEW (FLEX1UPN** shown) FS128B. CONTENTS: (#) indicates FLEX4UPN** quantity

8753E, 8753ET, and 8753ES Network Analyzer Option 1D5 High Stability Frequency Reference Upgrade Kit. Applicable Upgrade Kit Model Number

SCdefault. 900 Installation instructions. Accessories Part No. Group Date Instruction Part No. Replaces :36-29 Sep

Please Read First! The GPS 1100 default configuration of Hz is set to work with all Ag

Field Service Procedure Replacement GACP Control Panel Kit, ST24

2178 Fiber Optic Splice Case and 2181 Cable Addition Kit

2178-L/S Series Fiber Optic Splice Case with Gasket

Assembly Instructions

Welcome to your. Wireless transmitter and receiver kit

GENUINE PARTS. N-Bus harness for ipod Gateway 999U7-VS000 N-Bus harness for [optional] SAT Radio 999U7-VS001 FRONTIER, PATHFINDER & XTERRA (2005~)

M2 Antenna Systems, Inc. Model No: 23CM35

Ultra-Grip Crimp Connector Hand Tool Kit for Coaxial Cable and Powerpole Connectors

KEL 24 Cable entry frames

ELLIPTICAL ANTENNA E0851B11

FOSC 400. Ordering Guide For Closures and Accessories. Section I 3. Section II 5. Section III 9. Section IV 11. Section V 15

Single sensor setup with NIVEL210

CABLE MANAGEMENT PRODUCTS Cable Managers & Accessories

Bionic Elephant Trunk. Assembly Instructions

2100/2200/4100/6200 & MPB Series Bottom Mount Drive Pack. for Standard Load Parallel Shaft 60 Hz Gearmotors

Replacing the PanelMate epro PS, PanelMate epro PS EE, and PanelMate epro PS OD 7685x-12 Series Backlight Assembly

SLiC Fiber Aerial Closure System

2000 Series Weather Stations Analog Temperature / RH Sensor Upgrade Kit PRODUCT MANUAL KIT # 3613WDU

Original BMW Accessories. Installation Instructions.

QRO Coaxial Tee Fitting by WA4NJP, Ray Rector

8. Electronics. 8. Electronics. Electronics guide. Written By: Dozuki System manual.prusa3d.com Page 1 of 12

Butterfly Valve Retrofits

DS1 Cross-Aisle Panel

Warning and Safety Information. FCC Information

Aerospace Fiber Optics

Contents Section 9, Illustrated Parts

TECHNICAL GUIDE. TOUGH GUN ThruArm Series Robotic MIG Guns for MOTOMAN EA1400N, EA 1900N and SSA2000 Robots

VHF + UHF Amplified HDTV Antenna Model OA8000 & OA8001 Installation Instructions Reception Frequencies

NOTE: The illustrations in this manual may not look the same as your product, but your unit will function in the same way.

SOURCE COMMANDER MSS433 A/V SELECTOR OWNER S MANUAL INSTALLATION GUIDE

Remote Tuner Options for the DXE-MBVE-1 Vertical Antenna

INSTALLATION INSTRUCTIONS

Product group 1. Product description. At a glance. Cable entry systems for entering pre-terminated cables

Step 1. 1x NXT Ultrasonic Sensor

Installation instructions, accessories. Subwoofer. Volvo Car Corporation Gothenburg, Sweden. Page 1 / 29

Troubleshooting Guide 9630 Series

Hardware installation

DLP ANTENNA INSTRUCTION MANUAL. Dielectric LLC 22 Tower Road Raymond, Maine Phone:

HQ Electromagnetic Channel Locks. For the HQ Infinity

Electric Motorized Projection Screen PowerMax Tension Series

3M Fiber Optic Splice Closure 2178-XSB/XSB-FR & 2178-XLB/XLB-FR 3M Cable Addition Kit 2181-XB/XB-FR

MP Maker Pro Mk.1. Quick Start Guide

Transcription:

ISOBUS Retrofit Kit Ag Leader Technology Note: Indented items indicate parts included in an assembly listed above Part Name/Description Part Number Quantity ISOBUS Retrofit Kit 4100843 1 Hex Head Bolt 3/8" x 1-1/4 2002001-38125 2 Hex Nylock Nut 3/8" 2002055-38 2 Split Lock Washer 3/8" 2002061-38 4 Flat Washer 3/8" 2002071-38 4 Self Tapping Screw 5/16" x 3/4" 2002075-31075 4 Cable Tie 15 2002817-15 20 Cable Clamp 3/4" x 3/4" 2002867 2 Quick Reference Guide ISOBUS Virtual Terminal Troubleshooting 2006300 1 Installation Instructions 2006304 1 Dielectric Grease 2002872 1 ISOBUS IBBC/Power Relay Assembly 4002778 1 Cable ISOBUS Power Control Ext. (10FT) 4002585-10 1 Cable ISOBUS Active Termination 4002587 1 DISPLAY CABLE KIT ISOBUS (Ordered Separately) 4100842 1 Display Cable ISOBUS (12 FT) 4002506-12 1 Relay Power Control Assembly 4000708-1 1 Installation Instructions ISOBUS Display Cable 2005992 1 ISOBUS BATTERY CABLES (Ordered Separately) Cable ISOBUS Battery (8 FT) 4002865-8 Cable ISOBUS Battery (16 FT) 4002865-16 Cable ISOBUS Battery (22 FT) 4002865-22 (Pick One) RAM Base Mount 4100100 1 Lock Washer 2002065-06 4 Self Tapping Screw 1/4" x 3/4 2002075-25075 4 Phillips Pan Head Screw M6x1.0 2002435-06016 1 RAM 111B Base 4000187 1 RAM 201U Arm 5 4000279 1 RAM 2461U Base 4000280 1 PN: 2006304 Rev. C November 2013 Page 1 of 10

Ag Leader Technology ISOBUS Retrofit Kit Important Notices You will save time and prevent wrong installation of components by closely following these step-by-step instructions. If you have questions, call Ag Leader Technology at 515-232-5363 Ext 1. Direction words (LEFT and RIGHT) are commonly used when describing an installation procedure. Interpret direction words as if standing behind equipment and looking forward Signal words (CAUTION, IMPORTANT and NOTE) are provided to draw attention to information that is important for the safe/correct installation and operation of this product. CAUTION will alert you to situations that will impact the physical safety of you or others. IMPORTANT will alert you to the potential for damage to the product or loss of data. NOTE will provide you with additional information to simplify a procedure or clarify a process. Read all instructions first to familiarize yourself with the installation procedures. Keep parts list and installation instructions for use as a reference after completing installation. Section Contents Section Heading Page Common Components 3 Cable and Component Layout 4 Safety Notices 5 Installing the Display 6 Installing the Display Power Cable 7 Installing the ISOBUS Display Cable 9 Installing the ISOBUS IBBC/Power Relay Assembly 9-10 Setting up the Display 10 Page 2 of 10 November 2013 PN: 2006304 Rev. C

ISOBUS Retrofit Kit Ag Leader Technology Common Components The following are common components related to all ISOBUS Retrofit Kit installations. 1- ISOBUS IBBC/Power Relay Assembly 2- ISOBUS/Power Control Extension 3- ISOBUS Active Termination 1. ISOBUS IBBC/Power Relay Assembly 2. ISOBUS/Power Control Extension 3. ISOBUS Active Termination PN: 4002582 PN: 4002585-10 PN: 4002587 PN: 2006304 Rev. C November 2013 Page 3 of 10

Ag Leader Technology ISOBUS Retrofit Kit Component and Cable Layout Page 4 of 10 November 2013 PN: 2006304 Rev. C

ISOBUS Retrofit Kit Ag Leader Technology Safety Notices CAUTION: Turn off machine and wait for all motion to stop before starting work. Set parking brake. CAUTION: Be sure to wear proper eye protection when using any power tools, such as when drilling any mounting holes. IMPORTANT: Check behind vehicle and implement panels for any wiring or controls that could be damaged when drilling any holes. IMPORTANT: Disconnect the Display, and ISOBUS components from electrical system when welding on equipment or jump starting unit to prevent component damage due to power surges or excessive current. IMPORTANT: If using a non Ag Leader GPS receiver, make sure to install a Null Modem Cable, included in the Display Kit, to prevent damage to the Display or GPS receiver. IMPORTANT: Use Dielectric grease to coat the seals and terminals of each connector that will be exposed to weather or chemicals as you plug them in. NOTE: Be sure to follow the alignment keys on the plugs and the receptacles carefully. Do not use excessive force when mating connectors. PN: 2006304 Rev. C November 2013 Page 5 of 10

Ag Leader Technology ISOBUS Retrofit Kit Installing the Display Step-by-Step instructions for installing the Display Parts required for procedure: (1) Ag Leader Integra Display PN: 4002000-1 From RAM Mount Kit (4) Split Lock washer 6mm PN: 2002065-06 (4) Self Tapping Screw ¼"x3/4 PN: 2002075-25075 (4) Phillips Pan Head Screw M6x16 PN: 2002435-06016 (1) RAM 111B Base 2 x 6-1/4 PN: 4000187 (1) RAM 201U Arm 5 PN: 4000279 (1) RAM 2461U Base PN: 4000280 NOTE: If a display has been previously installed, this section may be skipped. 1. Attach the square RAM Display Mount, PN: 4000280 to the back of the Display using four 6mm Phillips pan head screws and lock washers provided in the RAM Mount Kit. 2. Determine a mounting place for the Display that will be a convenient place for operation, but out of the operator s line of sight while driving equipment. 3. Take the RAM Base Mount, PN: 4000187, and use the 13/32 drill and self-tapping screws as needed to secure the Base Mount. 4. Use the 5 RAM Arm, PN: 4000279 to mount the Display. Page 6 of 10 November 2013 PN: 2006304 Rev. C

ISOBUS Retrofit Kit Ag Leader Technology Installing the Display Power Cable Parts required for procedure (Pick One): Cable - Display/Guidance/High Current Power (5 FT) PN: 4002016-5 Cable - Display/Guidance/High Current Power (12 FT) PN: 4002016-12 Cable - Display/Guidance/High Current Power (22 FT) PN: 4002016-22 Cable - Display/Guidance Power (5 FT) PN: 4002026-5 Cable - Display/Guidance Power (12 FT) PN: 4002026-12 Cable - Display/Guidance Power (15 FT) PN: 4002026-15 Cable - Display/Guidance Power (22 FT) PN: 4002026-22 NOTE: A Power Cable from the list above is required for all installations. If a display and power cable has been previously installed, this section may be skipped. 1. Starting at tractor battery, route the selected Power Cable up into the cab. NOTE: Do not connect power cable to the battery, this will be done as a last step along with the power connection for the ISOBUS/IBBC Power Relay Assembly PN: 2006304 Rev. C November 2013 Page 7 of 10

Ag Leader Technology ISOBUS Retrofit Kit Installing the ISOBUS Display Cable From ISOBUS Retrofit Kit (1) ISOBUS/Power Control Ext. Cable (10FT) PN: 4002585-10 (1) ISOBUS Active Termination Cable PN: 4002587 Parts required for procedure: From Display Cable Kit- ISOBUS 4100842 (1) Display Cable- ISOBUS PN: 4002506-12 NOTE: Display Cable-ISOBUS, PN: 4002506-12 is required and replaces the standard display cable. Step-by-Step instructions for installing the ISOBUS Display Cable 1. If needed, remove the existing display if currently installed and replace with ISOBUS Display Cable, PN: 4002506-12 routing the connector bundle to the right side of the compartment as not to interfere with machine operation. 2. Feed the 28-pin AMP connector of ISOBUS Display Cable, PN: 4002506-12 to the back of the display. 3. Connect the 3 pin weather pack of the ISOBUS Display Cable, PN: 4002506-12 to 3 pin weather pack of Power Display/Guidance Cable, PN: 4002026-15. 4. Connect the 4 pin weather pack of the ISOBUS/Power Control Extension Cable, PN: 4002585-10 to the 4 pin weather pack of the ISOBUS Display Cable, PN: 4002506-12. 5. Connect the 4 pin Deutsch connector of the ISOBUS/Power Control Extension Cable, PN: 4002585-10 to the 4 pin Deutsch connector ISOBUS Tee of the ISOBUS Display Cable, PN: 4002506-12 and feed the ISOBUS/Power Control cable out the rear of cab. 6. Connect the ISOBUS Active Termination Cable, PN: 4002587 to the remaining 4 pin Deutsch connector of CAN B of the ISOBUS Display Cable, PN: 4002506-12. 7. Connect the round 28-pin connector on the Display Cable, to the connector labeled MAIN on the back of the display. Allow some slack in the Display Cable to allow for Display adjustment. Page 8 of 10 November 2013 PN: 2006304 Rev. C

ISOBUS Retrofit Kit Ag Leader Technology Installing the ISOBUS IBBC/Power Relay Assembly Parts required for procedure: From ISOBUS Retrofit Kit (1) ISOBUS IBBC/Power Relay Assembly PN: 4002778 (2) Hex Head Bolt 3/8" x 1-1/4 PN: 2002001-38125 (2) Hex Nylock Nut 3/8" PN: 2002055-38 (4) Split Lock Washer 3/8" PN: 2002061-38 (4) Flat Washer 3/8 PN: 2002071-38 (4) Self Tapping Screw 5/16 x 3/4 PN: 2002075-31075 (2) Cable Clamp 3/4" x 3/4" PN: 2002867 ISOBUS Battery Cable (Ordered Separately) (1) Cable ISOBUS Battery (8 FT) PN: 4002865-8 Or (1) Cable ISOBUS Battery (16 FT) PN: 4002865-16 Or (1) Cable ISOBUS Battery (22 FT) PN: 4002865-22 NOTE: The ISOBUS IBBC/ Power Relay Assembly has been designed with multiple mounting holes to allow for flexible installation. Fabrication of additional mounting hardware may be necessary. Step-by-Step instructions for installing the ISOBUS IBBC/Power Relay Assembly, Battery Cables, and Power Control Extension Cable. 1. Locate a spot to install the ISOBUS IBBC/Power Control Relay Assembly, PN: 4002778 on the rear of the tractor using included 5/16 Self Tapping Screws or any 3/8" hardware and any additional mounting brackets necessary. 2. Before securing the IBBC/Power Control Relay Assembly to mounting location, first connect the ISOBUS Battery Cable, PN: 4002865-X to the power terminals of the IBBC/Power Control Relay Assembly and slide protective covers over terminals. BLACK (NEGATIVE) RED (POSITIVE) 3. Secure the IBBC/ Power Control Relay Assembly to desired location so that it does not impede tractor or implement functionality. PN: 2006304 Rev. C November 2013 Page 9 of 10

Ag Leader Technology ISOBUS Retrofit Kit 4. Connect the 4 pin weather pack of the ISOBUS/Power Control Extension Cable, PN: 4002585-10 to the 4 pin weather pack on the CAN Power Relay Module of the IBBC/ Power Control Relay Assembly. 5. Connect the 4 pin Deutsch connector of the ISOBUS/Power Control Extension Cable, PN: 4002585-10 to the 4 pin receptacle on the back of the IBBC (Implement Bus Breakaway Connector) of the IBBC/ Power Control Relay Assembly. 6. Secure the Battery Cable and ISOBUS/Power Control Extension Cable to the housing with the provided Cable Clamps and 3/8" nuts and bolts. 7. Route the ISOBUS Battery Cable, PN: 4002865-X along the chassis to the battery away from heat sources and mechanical linkage, use provided cable ties to secure cable away from any moving parts. 8. Connect the Display Power Cable and the ISOBUS Battery Cable, PN: 4002865-X to the battery. 9. Installation of the ISOBUS Retrofit Kit has been completed. Setting Up the Display 1. Refer to Quick Reference ISOBUS Virtual Terminal Troubleshooting PN: 2006300 for setting up display for ISOBUS functionality. Page 10 of 10 November 2013 PN: 2006304 Rev. C