Connectix Cabling Systems

Similar documents
MPO Technology Connectivity & Application

How to Specify MTP Pre-terminated Optical Cabling. January White Paper. Published

HI-DEX PRODUCT SET DATASHEET

The Road to Single Mode: Direction for choosing, installing and testing single mode fiber

Cable Jacket - The outermost layer of the fiber cable. Application: Types Single mode Multi mode. Simplex or Duplex available

Fibre Optic Cable & Connector Guide

To select a fibre optic cable, you have to make choices of the fibre selection and the cable construction selection.

Enterprise Networks. Comms Room and Backbone. in DETAIL

Cable Installation Tips

Empowering businesses through innovative network solutions.

MT-RJ SECURE Product Expansion Now 10 Variants of the MT-RJ SECURE Products

Cable Installation Tips

TECHN. Purpose. Background. to prepare the. A A Patch cord. horizontal infrastructure

Structured Cabling. Product Line Brochure

Arista 40G Cabling and Transceivers: Q&A

ULTRA HIGH DENSITY SOLUTION GUIDE

MT Connect Pre-Terminated Fibre Cabling Systems

High Speed Data Connector (HSSDC) For 100 MBit/Sec Token Ring. John L. Hill AMP Incorporated July, 1998

Follow The Leader In Shielded Technology

Preferred ordering guide for NETCONNECT

Fibre Optic & Networking Products

Smart Choices. for Data Center

Instalaciones de fibra optica en entornos de centro de datos y campus para suportar 40, 100G y mas

Jacketed Fiber 900 µm. FC Ultra PC Blue boot represents ª 55 db reflectance. FC Angled PC. SC Ultra PC. SC Angled PC. LC Ultra PC.

Tech Breakfast: Fibre Optic Cabling

Fiber Optics Redefined

Product Catalogue. Fiber Optic Assemblies & Adapters. Table of Contents General Description... 2

Data Centres. Smart Solutions for 300 M OM4 120 M 120 M 400 M. Cat 8 30 M 85 M. Cat 7A 30 M OM3. Cat 6A 100 M OM4 OM3 85 M OM3 900 M 40G 40G 25G 100G

OPTICAL FIBRE CABLE NETWORK 2004/1

Keyed LC Connector Solution A LANscape Solutions Product

RCIT Cable Certification Testing Revised 10/2017

QuickNet Fiber Cabling in the Data Center

Assembly code page 46. Cable code page 47. Assembly classes page 48. Polarization maintaining assemblies page 52

DATA CENTER OPTICAL ASSEMBLIES TO SUPPORT QSFP, CFP AND CXP INDUSTRY STANDARD PINOUT CONFIGURATIONS

Delaware County Community College Project # Marple Campus Renovation - Phase % Construction Documents November 23, 2011

OPTICAL CHARACTERISTICS (applied to 12c MPO/MTP ) Item Parameter Reference

SYSTIMAX Solutions InstaPATCH 360 Pre-Terminated Fiber Solution Guide

We will look first at the cable, and then the transceivers (which act as both transmitter and receiver on each end of the fiber cable).

Jumpers & Pigtails. Fiber Type OM1, OM3, OM4, 0S1/OS2. Polarity Correction SC and LC duplex clip allows for polarity correction

INSTALLATION GUIDE. LANmark-OF Zone Distribution Box

D131x-apbpmslc TECHNICAL DATA. Fiber Optic Patch Cords Simplex LSZH. Description. Features & Benefits

Belden. Optical Fiber Catalog. Belden FiberExpress Systems, Cable and Connectivity

The need for Encircled Flux, real or imaginary?

Fiber Optic Patchcords & Cable Assemblies. Exclusive CD edition March 2006

Selection of a cable depends on functions such as The material Singlemode or multimode Step or graded index Wave length of the transmitter

Robert Burén. Product Manager. Nexans Cabling Solutions. 10G Solutions

P-AD ADAPTORS. Features: Low insertion loss Low back reflection loss Easy to handle Environmentally stable

NC-1000 INSTALLATION MANUAL NC-1000 FIBRE OPTIC CROSS-CONNECTION SYSTEM

GATOR PATCH. The ultimate fiber distribution terminal

UHD System ULTRA HIGH-DENSITY RACK-MOUNT FIBER CONNECTIVITY SYSTEM

Field Testing and Troubleshooting of PON LAN Networks per IEC Jim Davis Regional Marketing Engineer Fluke Networks

Product information. OpDAT VIK with breakout cable. Product description. Illustrations. Page 1/7

Game on! Plug n play. Plug and play with PryTerms our pre-terminated fibre optic cables. Read more

3M Telecommunications. Solutions for Networks. 3M MPO solutions. High Density Networks. Technology built for business

Connectivity accessories by Nestor Cables

Optimax Field Installable Connectors and Installation Tool Kits

LIIN-25 FO Pigtail FC (0.9mm)

NO MORE LOOSE ENDS PRE-TERMINATED FIBER CABLE: FAST. TESTED. READY TO GO (BBOX) BLACKBOX.COM/PRETERMFIBER

Pre-bid Supplement #01 Communications Specifications and Additional Scope Project Bid: CM Date: 05/26/2017

LANmark-OF ENSPACE Patch Panel

1 inputs / Optical signal for extension - Dot clock: 25 MHz to 600MHz - TMDS clock: 25 MHz to 300 MHz Video. - TMDS Single Link

SECTION 4 TABLE OF CONTENTS

SSA Fibre-Optic Extender 160 Fibre Installation Guidelines Version 1.2

RFP LC Uniboot to RFP LC Uniboot Patch cord, 2 fibres, Interconnect tight-buffered cable, LSZH

BLACK-BOX.EU/CONNECT

CUSTOM-LENGTH PATCH CABLES CUT-TO-LENGTH BULK FIBER PRE-TERMINATED FIBER MULTI-COLORED FIBER

40/100 Gb ETHERNET CABLING - A PERFECT STORM?

CONNECT TO VALUE THE SMART CHOICE WHEN PRICE MATTERS MOST BLACK-BOX.EU/CONNECT

3 DIMENSIONS OF EXCELLENCE PERFORMANCE SCALABILITY EFFICIENCY DATA CENTER LOCAL AREA NETWORK

MPS Webinar Technical Series

FirstLight Ultra High Density Pre-Terminated Module Datasheet

Compact Module. Category 6 FTP Cabling System

2U Sliding Patch Panel

Stretch More Out of Your Data Centre s Multimode Cabling System

Cabling Systems for Data Centers

IBM. Maintenance Information for Fiber Optic Links (FICON/FCP, Coupling Links, Open Systems Adapters, and zhyperlink Express) IBM Z SY

blackbox.com/connect The smart choice when price matters most. Need help? Talk to a Black Box cable expert 24/7 at

A. All communications equipment rooms shall be installed in a neat and workmanlike manner.

FREEDM Loose Tube Interlocking Armored Cables

COE Group plc. Contents

40G SWDM4 MSA Technical Specifications Optical Specifications

May Solution book Data Center

Singlemode Patch Cords and Pigtails

40G SWDM4 MSA Technical Specifications Optical Specifications

Fibre Channel Fiber-to-Fiber Media Converters

Optical links for the LHCb upgrade

Section Communications Optical Fiber Backbone Cabling

Installation. Step 1 Carefully unpack the package contents.

about dktcomega DKTCOMEGA s mission

Lensed Fibers & Tapered Ends Description:

Infinity Fibre Distribution Frame

Datasheet: MultiFiber Pro

FIBER OPTIC CABLE CUT TO YOUR EXACT SPECS TO SAVE YOU TIME AND MONEY

40GBd QSFP+ SR4 Transceiver

OPTICAL FIBERCONNECT. Version 3.

INSTALLATION MANUAL FT-FOTR-1VDE-ST-S

400GBASE-SR16 Cabling

Opterna. Sliding Fiber Optic Patch Panel. Sliding Fiber Optic Patch Panel. Visit: Opterna.com. Data Center Solutions. Introduction

Preferred ordering guide for NETCONNECT

Panduit HD Flex Fiber Cabling System: Built for Next-Generation Density Demands.

Transcription:

Connectix Cabling Systems Cabling Standards and CPR Update Connectix CEP Fibre Optic Solutions Jason Holroyd CNID Director of Business Development

Types of fibre Agenda Introduction Uses Construction Transmission Types Connectivity MPO/TP Data Centre Applications Polarity Explained Future Applications

Optical Fibre Cable Uses Overview of optical fibre Uses Indoor/Outdoor use Backbone Connectivity Connecting Buildings/Networks Long-Haul Connections High Bandwidth BD BD

Optical Fibre Cables Glass core Cladding (reflects light) Protection Larger core size, more loss

Types of fibre Multimode Fibre has a larger core and allows several modes to propagate while single mode only allows the first Multi-Mode Fiber n 2 n 1 n 1 Diameter n n (or fundamental) mode to propagate Single Mode Fiber n 2 Diameter Light Sources - LED VCSEL Laser

Types of fibre Multimode Fibre OM1 62.5/125 OM2 50/125 OM3 50/125 OM4 50.125 Defined Sheath Colour Orange Orange Aqua Heather Violet Singlemode Fibre OS1 9/125 OS2 9/125 Yellow Yellow

Optical Fibre Cables Cable construction refers to how fibres are combined into a useable cable 2 cable constructions Loose Tube Tight Buffered Armoured for protection and installation considerations

Optical Fibre Patch Panels Permanently installed fibre should always be presented in a break out box or fibre patch tray (patch panel) Fibre presentation at couplers should match patch cords Simplex / Duplex options Wall, floor or rack mountable

Optical Fibre Connections Equipment Rack

Fibre Connector Types Mechanically coupled, quicker than splicing. SC LC FC ST MPO/MTP SC APC LC APC FC APC E2000 Transceiver APC 8 degree (angled polish enables reflections to leave core due to angle Vs UPC that sees reflections propagate back through fibre) Connector families Straight Tip, Subscriber, Small Form Factor (SFF)

Fibre Connector Types LC Simplex / Duplex ST SC Simplex / Duplex FC VF-45 MT-RJ

MPO / MTP Connectix Cabling Systems TM Fibre Solutions

Connectix Cabling Systems TM Fibre Solutions MPO / MTP MPO Multiple-fibre Push-On/Pull-off MTP Brand name for US Conec version 12 Fibres in a single connector Factory terminated Available as Multimode & Singlemode

Connectix Cabling Systems TM Fibre Solutions Products Trunk Cables Cassettes Break-out cables Patch Leads MPO/MTP through coupler panels

Connectix Cabling Systems TM Fibre Solutions Why use MTP? Falls into two areas Pre-terminated Parallel Optics (multimode) 40 Gigabit Ethernet 100 Gigabit Ethernet

Connectix Cabling Systems TM Fibre Solutions Pre-terminated Less time onsite No fibre splice equipment required onsite Plug and play Standard Patch Panel 3 cassettes Mix SM & MM in one panel Low risk expansion

Connectix Cabling Systems TM Fibre Solutions Parallel Optics Fibre requires 2 cores (Transmit & Receive) Ethernet standards 10 Gigabit Ethernet Parallel Optics uses multiple fibres for transmit and receive

Connectix Cabling Systems TM Fibre Solutions 40 & 100 Gigabit Ethernet 100GBASE-SR10 1 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7 8 9 10 11 12 Vertically stacked ports 40GBASE-SR4 1 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7 8 9 10 11 12 Side by side ports 1 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Single port

Connectix Cabling Systems TM Fibre Solutions Polarity Maintenance Duplex Hardware Requires a cross-over somewhere Tx Rx Rx Tx Array cables a little more complicated... 12 cores needs to work for 6 off Duplex 8 core & 20 core Parallel Optics

Connectix Cabling Systems TM Fibre Solutions Available Schemes BS EN 50174-1:2009+A1:2011 1 Scheme ANSI / TIA-568-C.0 3 Schemes Method A, B & C Which to choose? EN standards adopted by member states Only 1 to choose from

Connectix Cabling Systems TM Fibre Solutions EN 50174 Scheme Array connector cable or patch cord Key-up to key-up Array adapter Aligned keyways

Connectix Cabling Systems TM Fibre Solutions EN 50174 Scheme - Transition assembly (Cassette)

EN 50174 Scheme - Complete Array Connectix Cabling Systems TM Fibre Solutions

EN 50174 Scheme - Duplex Cabling Connectix Cabling Systems TM Fibre Solutions

Developments Connectix Cabling Systems TM Fibre Solutions

Connectix Cabling Systems TM Fibre Solutions Developments Standard Modular Cassette XS Cable Management

Connectix Cabling Systems TM Fibre Solutions Developments FibrePro Patch Panel

Connectix Cabling Systems TM Fibre Solutions HD 3U Patch Panel Cassette Based 576 Core fibre capability

Connectix Cabling Systems TM Fibre Solutions HD 3U Patch Panel 5 Cassettes? Reversible? Hinged patch lead protector Doubles as labelling field Uses USConec low loss version of the MPO Standard Low Loss Insertion Loss 1 db 0.35 db Return Loss > 20 db > 35 db

Thank You Connectix Cabling Systems TM Fibre Solutions