Room Recommendations for the Cisco TelePresence System 3210

Similar documents
Room Recommendations for the Cisco TelePresence System 3010

Cabling and Completing Assembly of the Cisco TelePresence System 1000

QCTV PROGRAM REPORT. Council Chambers Presentation Audiovisual Systems. Member Cities: Andover, Anoka, Champlin, and Ramsey

Tele-Conferencing Rooms

Assembling and Mounting the Presentation Display, Speakers, Speaker Screens, and Table Door

Troubleshooting the CTS 1100

APPENDIX O RECOMMENDED GUIDELINES FOR AUDIO/VISUAL TECHNOLOGIES (AV TECHNOLOGY) TABLE OF CONTENTS E. CATV... 8 F. SECURITY SYSTEM...

DESIGN CRITERIA AND REQUIREMENTS FOR CLASSROOMS

EXHIBIT BASIS OF DESIGN REPORT. Space Type: Space Usage: Approx. 2,000 BTU each. Off-center of room to match side screen.

EXHIBIT BASIS OF DESIGN REPORT. Space Type: Space Usage: Off-center of room to match side screen. Location

The Ideal Videoconferencing Room

NEC Display Solutions of America, Inc. U300X Installation Guide Desktop and Ceiling Mount v1.3

ENERGY STAR Program Requirements Product Specification for Televisions. Eligibility Criteria Version 5.3

ENERGY STAR Program Requirements Product Specification for Televisions. Eligibility Criteria Draft 1 Version 6.0

MAKE ROOM FOR BETTER MEETINGS. The IT & Facility Manager s guide

Queens College Technology Enhanced Classroom (TEC) Specifications 9/2008

BILOXI PUBLIC SCHOOL DISTRICT. Biloxi Junior High School

Using Extra Loudspeakers and Sound Reinforcement

DISTRIBUTION AMPLIFIER

R OPTEVA 868 THROUGH THE WALL ATM. 305mm (12") MAXIMUM WALL THICKNESS IN AREA OF UNIT OUTLINE OF OPTIONAL ILLUMINATED SIGNAGE PANEL

Vortex / VSX TM 8000 Integration

R OPTEVA 868 THROUGH THE WALL ATM. 305mm (12") MAXIMUM WALL THICKNESS IN AREA OF UNIT OUTLINE OF OPTIONAL ILLUMINATED SIGNAGE PANEL

IPSTB1200 /IPC3200 Media Client User guide

UHM CLASSROOM DESIGN GUIDELINES

VIDEO CONFERENCE STANDARDS

VidyoPanorama Design Guide. Howard Lichtman & David Maldow

MON3-2W/HR MON4-2W/HR (Document P/N Rev-B)

HDMI over CAT5 Extender with IR and Serial - HDBaseT Extender - 4K

BUREAU OF ENERGY EFFICIENCY

COLUMBIA COUNTY, WISCONSIN COURTROOM VIDEO CONFERENCE & AV SYSTEMS REQUEST FOR PROPOSALS

Information Technology Services DESIGN AND INSTALLATION STANDARDS

Using Extra Loudspeakers and Sound Reinforcement

User s Manual. Digital Media Converter Package Part #: DL-HDCAT

Equipment, Systems, and Network

A. All equipment and materials used shall be standard components that are regularly manufactured and used in the manufacturer s system.

Multi-Purpose Auditorium Sound Reinforcement System Design ECE Spring 2017

Cisco Video Surveillance 6400 IP Camera

Target Interface / Construction Compliance Inspection Checklist

PT-LB385 S P E C F I L E. LCD Projectors. As of December Specifications and appearance are subject to change without notice.

FogScreen emotion Projection Screen. User Manual Part 1: Installation Guidelines

Radiography and Mammography Viewing Systems

HDMI over CAT5 HDBaseT Extender - Power over Cable - Ultra HD 4K

PT-LB382 S P E C F I L E. LCD Projectors. As of July Specifications and appearance are subject to change without notice. 1/9.

replacement systems. PT-F200 Series Permanent-Installation Projectors Please make these projectors your very first recommendations as new or

DIN-1DIMU4. DIN Rail Universal Dimmer, 1 feed, 4 channels

StepArray+ Self-powered digitally steerable column loudspeakers

MANUAL ENGLISH Core Club Ordercode: D2314

HDMI over CAT5 HDBaseT Extender - 4K

User s Manual. Digital Media Converter Package Part #: DL-HDCAT-WP

Wall Plate HDMI over CAT5 Extender with Power Over Cable 1080p 165ft (50m)

A Real Word Case Study E- Trap by Bag End Ovasen Studios, New York City

A Real Word Case Study E- Trap by Bag End Ovasen Studios, New York City

CLASSROOM ACOUSTICS OF MCNEESE STATE UNIVER- SITY

Power Injector 1520 Series

1x12 VGA & Audio over CAT5 Splitter

MAW218D7. User s manual. Pol.Ind.Norte-Perpinyà, TERRASSA (Barcelona-SPAIN)

AV KEEPS NYC SECURE JAIL IS UNDER CONTROL GREETINGS FROM MARS NYPD S EOC SERVES MULTIPLE PURPOSES.

** DRAFT ** GUIDELINES. For the Design and Construction of Classrooms, Conference and Seminar Rooms, and other Presentation Spaces.

Product Number : LW373 Product Name : As of October Specifications and appearance are subject to change without notice.

VITEK VTM-TLM191 VTM-TLM240

OPTEVA 828 LOBBY ATM FRONT LOAD PLAN VIEW FRONT ELEVATION SIDE ELEVATION

PT-LW330 S P E C F I L E. LCD Projectors. As of April Specifications and appearance are subject to change without notice. 1/9.

PROJECT WORKPLACE DEVELOPMENT

Cisco Telepresence SX20 Quick Set - Evaluation results main document

Panaray MSA12X. Modular Steerable Array Loudspeaker. Design Guide

Setting up the Setting up the Dragonfly 1 v June

PURCHASING DEPARTMENT. Project # Addendum # # of pages Original Issue Date Request Doc # April 15, see text below

Environmental Conditions, page 2-1 Site-Specific Conditions, page 2-3 Physical Interfaces (I/O Ports), page 2-4 Internal LEDs, page 2-8

Media Tube CW x 48.5mm 1.12 x mm mm mm kg 5.1lbs. 1.6kg 3.5lbs

N2300 Series N2315 Networked AV Wallplate 4K Encoder NMX-ENC-N2315-WP-BL (FGN2315-WP-BL), Black NMX-ENC-N2315-WP-WH (FGN2315-WP-WH), White

PT-TX400 S P E C F I L E. LCD Projectors. As of December Specifications and appearance are subject to change without notice.

S0 Radio Broadcasting Mixer. June catalogue. Manufacturers of audio & video products for radio & TV broadcasters

Dynamic Digital Signage. Leveraging the Newest Display Technology for Your Messaging or Branding Needs. A Partner of

PT-TW340 S P E C F I L E. LCD Projectors. As of May Specifications and appearance are subject to change without notice. 1/8.

Ultra Short-throw Projectors <LV-WX300UST >

Product Number : TW350 Product Name : As of October Specifications and appearance are subject to change without notice.

Operating instructions III / 2004

PT-LB300 S P E C F I L E. LCD Projectors. As of April Specifications and appearance are subject to change without notice. 1/8.

Tech Paper: Modernizing the Company Cafeteria

SPX-5600 Series. Operations Manual. Suprex Reader Extender - RF Wireless Interface SPX-5600MAN. Page 1 of 20

Cisco DAXI. Features. Data Sheet. Cisco DAXI. Figure 1.

Don t let Potential Customers pass you by!

HDMI over CAT5 HDBaseT Extender - Power over Cable - IR - RS232-10/100 Ethernet - Ultra HD 4K ft (100m)

Cyclo Series. user manual. MartinArchitectural

Interview Management System Installation Guide. (303) x500

VIDEO MATRIX SWITCHES HDMI 2.0

CEA Bulletin. Home Theater Recommended Practice: Audio Design CEA/CEDIA-CEB22

PART 1: HARDWARE. Author: Vandermeerschen M. Version

SmartVideo: SSV Feature Summary

Application Notes on the ClearOne Beamforming Microphone Array

HDMI over Wireless Extender - 65 ft. (20 m) p

Ultra-short-throw projectors with connectivity for the BYOD classroom.

PLV-Z2 ROLL THE FILM FOR THE FUTURE!

The Management Committee of the BEREC Office,

Remote Control. degraded, causing unreliable operation. The recommended effective distance for remote operation is about 16 feet (5 meters).

Product Number : LB303 Product Name : As of October Specifications and appearance are subject to change without notice.

Cisco RF Gateway 1. Product Overview

Selecting Cables for Power over Ethernet

USER MANUAL. 27 Full HD Widescreen LED Monitor L27ADS

AMX Precis HDBaseT Receiver and Scaler For use with the Precis 8x8 4K60 HDMI matrix switcher PR01-RX (FG )

Transcription:

CHAPTER 2 Room Recommendations for the Cisco TelePresence System 3210 Revised: February 20, 2012, This chapter provides you with general room recommendations for the Cisco TelePresence System 3210 (CTS 3210) and includes the following sections: Summary of Room Requirements, page 2-1 Room Dimensions, page 2-2 Acoustic Considerations, page 2-3 Lighting Considerations, page 2-4 Network Port Requirements, page 2-9 Power Requirements, page 2-10 HVAC Considerations, page 2-12 Auxiliary Display Considerations, page 2-13 Cabling Considerations for Second Row Seating, page 2-14 Summary of Room Requirements Table 2-1 summarizes the room requirements for the CTS 3210: Table 2-1 Summarization of Room Requirements for CTS 3210 Room Size Minimum Depth / Width / Height 23' x 31' x 8' (7.01 m x 9.45 m x 2.44 m) Lighting Acoustics 300-400 lux Facial Light (vertical plane) Twice the facial light or less for Shoulder Light (work surface) Ambient Noise 45dBA SPL NC30 Reverberation 150-700ms Acoustic Panel on Side walls 2-1

Room Dimensions Chapter 2 Room Recommendations for the Cisco TelePresence System 3210 Table 2-1 Summarization of Room Requirements for CTS 3210 (continued) Power HVAC Design 3.19kW Max 6 dedicated circuits Participant convenient ports consume additional power Independent Room Control Typical Cooling 12,800 BTU/Hr Aesthetic Continuity highly desirable For best video quality: Avoid high contrast elements such as very dark or bright colors Avoid glossy finishes Avoid clutter The following sections elaborate on each requirement. Room Dimensions For the CTS 3210, rectangular rooms are preferred although irregular shaped rooms can also be accommodated. The minimum and recommended room sizes for a Cisco TelePresence 3210 system are provided in Table 2-2 and Table 2-3. Table 2-2 18 Seat Room Dimensions Width Depth Height Minimum 31 (9.45 m) 23 (7.01 m) 8 (2.44 m) Recommended 31 (9.45 m) 26 (7.92 m) 10 (3.05 m) Maximum To be determined 26 (7.92 m) Greater than 10 may require acoustic wall treatment Table 2-3 14 Seat Room Dimensions Width Depth Height Minimum 24 (7.32 m) 23 (7.01 m) 8 (2.44 m) Recommended 24 (7.32 m) 26 (7.92 m) 10 (3.05 m) To be determined 26 (7.92 m) Greater than 10 (3.05 m) may require acoustic wall Maximum treatment Note Ceilings lower than 7 (2.13m) will not physically support the height of the CTS endpoint lighting façade. 2-2

Chapter 2 Room Recommendations for the Cisco TelePresence System 3210 Acoustic Considerations Acoustic Considerations For the immersive CTS 3210 meeting environment, the specifications are: Ambient Noise less than 45 dba (ideally at 36 dba) RT60 less than 500 ms (not to exceed 700 ms for non voice critical freq) Noise Criteria no greater than 30 Meeting rooms large enough to accommodate an 18 seat or 14 seat CTS 3210 built of drywall, suspended ceilings, and carpeting that have exposed, parallel hard surfaces, usually promote reverberation to levels greater than 500ms to nearly 900ms (1.2 seconds), creating echoes in the room. The echo cancellation in the CTS 3210 codec may compensate for this in the audio broadcast to remote participants; however, local sound quality will be degraded in this type of unremediated acoustic environment. Because of this, acoustic treatment is required for CTS 3210 rooms. There are two options for acoustic treatment, installing asymmetrical acoustic panels or applying acoustic treatment to all wall surfaces in the room. Asymmetrical Acoustic Wall Treatment As shown in Figure 2-1, staggered acoustic panels are placed on the opposing drywall surfaces such that no bare wall surfaces face each other. This option provides more natural (versus less recording studio-like) sound characteristics in the room. Figure 2-1 Asymmetrical Treatment with Acoustic Panels 2-3

Lighting Considerations Chapter 2 Room Recommendations for the Cisco TelePresence System 3210 Table 2-4 Description of Callout for Figure 2-1 Callout Description 1 Acoustic panel mounted on wall surface. Complete Acoustic Wall Treatment In complete acoustic wall treatment, all wall surfaces are covered by acoustic paneling, as shown in the following figure, though not necessarily from floor to ceiling. This creates a recording studio-like audio environment. This is optimal for clarity of audio transmission during a meeting and for recording meetings for playback; however, in-room participants may find the room uncomfortably muted or muffled as natural environments contain reverberation and echo. Which acoustic treatment you choose should be based how the room will be used and the participant expectations of the room experience. Figure 2-2 Complete Treatment Acoustic Panel Treatment Table 2-5 Description of Callout for Figure 2-2 Callout Description 1 Continuous acoustic paneling covering all room walls. Lighting Considerations The Cisco TelePresence 3210 System requires the following lighting levels. 2-4

Chapter 2 Room Recommendations for the Cisco TelePresence System 3210 Lighting Considerations Table 2-6 CTS 3210 Room Lighting Levels Illumination Target Tolerance Note Overall illumination 300-400 lux + or 50 lux Measured vertically w/ light sensor lux (= lm/m2) Lighting should be evenly pointed at wall or intended camera dispersed throughout the room. location (not pointed at ceiling) Shoulder light/direct down light. Lighting Dispersion Color Temperature Etc. No more than twice the overall illumination of the room. Generally, shoulder lighting should not be more than 400 lux greater than the overall illumination of the room and never exceed 800 lux. Measured horizontally at table height w/ light sensor pointed at ceiling For all other general Cisco TelePresence room lighting recommendations, refer to the Cisco TelePresence Room Design Guide at the following URL: http://www.cisco.com/en/us/solutions/ ns669/networking_solutions_products_genericcontent0900aecd80554cb2.html There are four recommended lighting fixture placement options, all of which have the same goal, to provide even, indirect lighting throughout the room. Which option you choose depends upon your choice of lighting fixtures. Caution The following examples are for reference only. Please consult your lighting manufacturer s specifications for the adequate number and proper layout of fixtures to achieve the lighting levels mentioned above. For example, lights that are brighter than the averages tested for this guide may require fewer placements. Likewise, dimmer than tested light sources may require a greater density of fixture placements. 2-5

Lighting Considerations Chapter 2 Room Recommendations for the Cisco TelePresence System 3210 Figure 2-3 Option 1: Recessed Indirect Lighting Fixture Placement Table 2-7 Callouts for Figure 2-3 Callout Description 1 Ceiling-installed 2 x 4 (0.61 m x 1.22 m) recessed indirect lighting fixtures. 2-6

Chapter 2 Room Recommendations for the Cisco TelePresence System 3210 Lighting Considerations Figure 2-4 Option 2: Indirect Pendant and Recessed Indirect Lighting Fixtures Table 2-8 Callouts for Figure 2-4 Callout Description 1 Ceiling-installed indirect pendant lighting fixture. 2 Ceiling-installed 2 x 4 (0.61 m x 1.22 m) recessed indirect lighting fixtures. 2-7

Lighting Considerations Chapter 2 Room Recommendations for the Cisco TelePresence System 3210 Figure 2-5 Option 3: Indirect Pendant with Recessed Indirect Lighting Fixtures Table 2-9 Callouts for Figure 2-5 Callout Description 1 Ceiling-installed indirect pendant lighting fixtures. 2 Ceiling-installed 2 x 4 (0.61 m x 1.22 m) recessed indirect lighting fixtures. 2-8

Chapter 2 Room Recommendations for the Cisco TelePresence System 3210 Network Port Requirements Figure 2-6 Option 4: 2 x 2 (0.61 m x 0.61 m) Recessed Indirect Lighting Fixtures Table 2-10 Callouts for Figure 2-6 Callout Description 1 Ceiling-installed 2 x 2 (0.61 m x 0.61 m) recessed indirect lighting fixtures Network Port Requirements The CTS 3210 requires a single Gigabit Ethernet port (RJ-45 UTP) installed on the wall behind the system. This port connects the CTS primary codec (the main interface between the CTS endpoint and the network) to the network infrastructure. The CTS primary codec (required) and participant convenience port connectivity options are listed in Table 2-11. Table 2-11 CTS 3210 Network Access Requirements Description # of Ports Connection Notes CTS Codec Required 1 Wired RJ-45 UTP Gigabit Ethernet on the wall behind the system. Codec connectivity is required regardless of the participant access type. Participants Option 1 1 Wireless Customer must provide wireless access. Participants Option 2 1 Wired with switch in room An additional RJ-45 UTP port should be provided on the wall behind the system for the switch. 2-9

Power Requirements Chapter 2 Room Recommendations for the Cisco TelePresence System 3210 Please consult with your network administrator on which method is best for your telepresence deployment. Note Any switches installed in the TelePresence room must meet the company s network policies. They must also meet the sound requirements of TelePresence. Switches should not generate more than 45dB of sound within the TelePresence room. Power Requirements The Cisco TelePresence System 3210 requires six dedicated 20Amp circuits @120V (US electrical code requires maximum 16A on a 20Amp circuit) or six dedicated 10amp circuits @ 240V. These circuits must be dedicated to the Cisco TelePresence System. Of these six circuits: Four circuits should be located on the wall behind the system for the plasma screens, codecs, and front table of participant convenience ports. Two circuits should be provided via cable trench or under-carpet cabling solution to the back table participant convenience ports. Note Peripherals such as document cameras or alternate displays will require additional circuits and receptacles. Placement will depend on the type and location of the peripheral. To connect the CTS system components to the power circuits, the CTS 3210 and CTS 3200 both use Power Distribution Units (PDUs). Each PDU must support 20 amps@120v or 10 amps@240v, depending on your installation choice. To provide power to second row participants, you need to provide an electrical power source that is located to the right side of the second row table. For more information, see the Cabling Considerations for Second Row Seating section on page 2-14. For an example, see Figure 7-13. Table 2-12 CTS 3210 Power Distribution Circuit 1 2 3 4 5 6 Connected to Circuit 1 PDU 1 PDU 2 PDUs 1 PDU 1 PDU 1 Auxiliary Control Unit (ACU) Connected to PDU or ACU 1 Display 2 Codecs 1 Display 1 Codec 1 40 LCD Display 6 AC Ports for first row seating AC Ports for second row seating AC Ports for second row seating 1 Display 5 Lighting 2-10

Chapter 2 Room Recommendations for the Cisco TelePresence System 3210 Power Requirements Table 2-13 CTS 3200 Power Distribution Circuit 1 2 3 4 5 6 Connected to Circuit 1 PDU 1 PDU 1 PDU 1 PDU 1 PDU 1 ACU Connected to PDU or ACU 1 Display 2 Codecs 1 Display 1 Codec 1 Projector 6 AC Ports for first row seating AC Ports for second row seating AC Ports for second row seating 1 Display 5 Lighting Table 2-14 summarizes the power consumption for the CTS 3210 and CTS 3200. Note Peripherals are not included in the following power requirement tables. Table 2-14 CTS 3210 and CTS 3200 Power Consumption Component Maximum Typical Idle kw Amperage @120V kw Amperage @120V kw Amperage @120V 65 Plasma Display x3 (CTS 3200) 3.24 27.00 2.34 16.95 0.002 0.02 65 Plasma Display x3 (CTS 3210) 1.71 14.25 1.71 14.25 0.001 0.01 Primary Codec x1 0.30 2.50 0.13 1.00 0.12 1.00 Secondary Codec x2 0.36 3.00 0.23 1.88 0.22 1.80 Lighting Façade Top x 3 + Sides x 2 0.35 2.91 0.35 2.91 0.00 0.00 Auxiliary Control Unit (ACU) 0.02 0.20 0.02 0.20 0.00 0.00 Projector x1 for first row seating (CTS 0.29 2.40 0.23 1.70 0.001 0.01 3200) 40 LCD for first row seating 0.22 1.83 0.18 1.50 0.001 0.01 (CTS 3210) Optional 40 LCD for second row 0.22 1.83 0.18 1.50 0.001 0.01 seating A/V Expansion Unit 0.01 0.08 0.01 0.08 0.00 0.00 POWER TOTAL for 3200 4.79 kw 3.48 kw 0.34 kw 39.92 amps @ 120V 19.96 amps @ 240V 26.22 amps @ 120V 14.49 amps @ 240V 2.83 amps @ 120V 1.41 amps @ 240V 2-11

HVAC Considerations Chapter 2 Room Recommendations for the Cisco TelePresence System 3210 Table 2-14 CTS 3210 and CTS 3200 Power Consumption (continued) Component Maximum Typical Idle kw Amperage @120V POWER TOTAL for 3210 3.19 kw 26.61 amps @ 120V 13.30 amps @ 240V 2.80 kw 23.32 amps @ 120V 11.68 amps @ 240V 0.34 kw 2.83 amps @ 120V 1.41 amps @ 240V Optional: Additional Power Requirements for power in Table Legs Participant Convenient ports (18 participants) 4.32 36.00 0.440 3.66 0.00 0.00 kw Amperage @120V kw Amperage @120V HVAC Considerations Planning the cooling for a CTS 3210 TelePresence room is important to ensure the room remains comfortable for people in it and to protect the equipment by maintaining normal operating temperatures. Caution HVAC considerations should be given from the initial phase of choosing a room. Installing new cooling (or heating) systems can be time-consuming. The table summarizes the specific BTU output of a CTS 3210 when deployed as recommended and under typical operating conditions. Please provide this information to your building HVAC engineer. The qualifier typically assumes: The system is not used constantly 24 hours a day, seven days a week, every week. Deployment follows Cisco recommendations. The room is located within a building interior. The room has proper air circulation. The room s walls are painted with neutral colors. Note For more information about specific wall colors, refer to the Cisco TelePresence Wall Color Guide available at the following URL: http://www.cisco.com/en/us/solutions/ns669/ networking_solutions_products_genericcontent0900aecd80554cb2.html The target room temperature expected is 72-76 degrees F. From these guidelines and for typical usage, a diversity factor of 25 percent is assumed which lowers cooling requirements. Note Conditions not consistent with the above may require additional cooling. Consult with your HVAC engineer to define building envelope and unique requirements. Additional equipment such as data displays, document cameras, etc., require additional cooling. 2-12

Chapter 2 Room Recommendations for the Cisco TelePresence System 3210 Auxiliary Display Considerations Table 2-15 CTS 3200 and CTS 3210 BTU Output with 25% diversity CTS 3200 CTS 3210 Source Typical KW Typical Usage BTUs/hr Typical kw Typical Usage BTUs/hr System Power 3.13 8011 2.46 6286 System Lighting 0.35 891 0.35 891 12 Participants (Avg) 0.78 1997 0.78 1997 8 Laptops (Avg) 0.44 1126 0.44 1126 Ceiling Lights (1.4w/sqft) 0.99 2534 0.99 2534 Total Typical Heat Dissipation 14,600 BTU/Hr Total Typical Heat Dissipation 12,800 BTU/Hr Auxiliary Display Considerations The CTS 3200 comes with a data projector, designed to project onto the white screen below its three primary video displays. The CTS 3210 likewise has an LCD display below its three primary video displays. For both the CTS 3200 and CTS 3210, content below the primary video displays is difficult for participants in the second row to see. The solution to this is that both systems include a 4-port HDMI splitter for additional external displays as part of the audio-video expansion unit. This splitter enables you to add up to three additional data displays in the room so that second-row participants can easily view shared data. It also gives you flexibility to choose the number, size, and location of the extra displays in the room. We would recommend at least a 50 inch display when using one in the center above the CTS unit or two 46 inches displays when they are located on both sides of the unit, as shown in Figure 2-7. Figure 2-7 Auxiliary Display Considerations 2-13

Cabling Considerations for Second Row Seating Chapter 2 Room Recommendations for the Cisco TelePresence System 3210 Table 2-16 Callouts for Figure 2-7 Callout Description 1 Height for a side mounted position is 64 (162 cm) from floor. 2 Distance from the ceiling varies depending on ceiling height. Check the height of the room prior to additional display selection and installation. The CTS system itself is 7 feet (2.13m) high. 3 The lateral position for a side mounted position is 10 4 (313 cm) from center of CTS 3210. Cabling Considerations for Second Row Seating To connect the participant convenience ports in the CTS 3200 or CTS 3210 second row seating, a cable trench or an under-carpet cable conveyance solution is recommended. The position of the trench or cable conveyance is shown in Figure 2-8 and Figure 2-9. You use this conveyance to provide access between the rear of the system and the microphone cables for the second row. You can also use this conveyance to add power and Ethernet connectivity for second row conference participants. To add power connectivity, you need to provide a floor-mounted electrical termination unit (for example, a junction box with two electrical outlets) on the right edge of the second row table. See Figure 7-13 for an example. The trench or cable conveyance should be able to allow a clear separation between the power cable, microphone cable, and Ethernet cable bundles. One exit of the trench should come out behind the right plasma. The microphones are connected through a microphone extension lead and the maximum distance between the microphones to the codec is 17.5 meters (57.4 feet). The extension microphone lead is 9 meters (29.5 feet). Any longer distance between the microphone and primary codec introduces noise and is not supported. The Ethernet cables which are connecting the participants in the second row are 10 meters (32.8 feet) long and the two Power Distribution Units which are used to provide power to the second row have 7 meter (23 feet) long cables. If you are unable to route the cables under the floor, be sure that your alternative solution (such as an under-carpet cable conveyance) follows all local fire, building, accessibility, and safety codes. Alternately, power and data could be taken directly from the back wall in another trench as long as it follows all local fire, building and safety codes. Note The trenching guidelines in these figures use the minimum distance of the system to the rear wall, which is four inches (10.2 cm). If you increase the distance between the system and the rear wall, increase the distance between the trench and the rear wall by the same amount. 2-14

Chapter 2 Room Recommendations for the Cisco TelePresence System 3210 Cabling Considerations for Second Row Seating Figure 2-8 Cable Trench Location for CTS 3210 with 18 Seats 4.0 in (10.2 cm) 76 in (193 cm) 12 in (30.5 cm) 128.9 in (327.5 cm) 8 in (20.3 cm) 124.5 in (316.2 cm) 139 in (353.1 cm) 209240 2-15

Cabling Considerations for Second Row Seating Chapter 2 Room Recommendations for the Cisco TelePresence System 3210 Figure 2-9 Cable Trench Location for CTS 3210 with 14 Seats (CTS 3210 Reduced Configuration) 4.0 in (10.2 cm) 71.7 in (182 cm) 11.2 in (28.4 cm) 8 in (20.3 cm) 149 in (378.5 cm) 157.7 in (400.5 cm) 98.8 in (251 cm) 209241 2-16