XTM72E & F Real-Time Clock Modules

Similar documents
XTM72 Exerciser Timer Module

INSTALLATION & OPERATING INSTRUCTIONS SINGLE/TWO CHANNEL 24HR/7 DAY TIMER. Cat No. TR671/TR672TOP

Two (2) Channel 365 Day 24 Hr. Timer/Controllers

System pro M DT1-IK DT1-IK/24V DT1-IK/DCF DT2-IK 2CSM204275R0611 2CSM441017D5601 2CSM204285R0611 2CSM204295R0611 2CSM204325R0611

Simply clever! The digital DIN-rail time switches by Grässlin

Overview: Specifications: Installation Instructions:

FW/S Digital time switch 2CDG120039R0011 D GB F I E NL. Installation and operating instructions FW/S DCF antenna GPS antenna SELV MENU

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

Weekly Time Switch. Rated time Time setting range Time division 24 hrs x 7 days 00:00 to 23:59 1min

Philips LightMaster. KNX Timeclock Installation and Operation Manual

ULTRA-VANSTAT WIRELESS PROGRAMMABLE THERMOSTAT FOR CARAVANS

24 Hour & 7 Day Digital Immersion Heater Timeswitch Article

PT Two (2) Channel 365 Day 24 Hr. Timer/Controller

SSPT724A Timer Quick Start Guide

FN:4181M5.DOC MC4181N SERIES MASTER CLOCKS MC4181N

FN:4181NX_M1.DOC MC4181NX MASTER CLOCK MC4181NX

1 Overview. 2 Specifications. 3 Installation Instructions. HPT724 Programmable LCD Timer PN 52765:A 1/25/06 ECN Product Installation Document

SCS318. User Instructions. SCS318 comprising of SCS317 7 Day Wireless Programmable Room Thermostat and SSR303 Receiver

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

ST9100C User Guide. Features

16 Amp Electronic 24 Hour/7 Day Time Controller

Programmable time switches Multiple function - daily/weekly

talento 800 Series 365-Day One, Two and Four Circuit Electronic Time Controls Functional Description

2 2 Relay outputs. M DIN W72 H7mm. LE7 Weekly/Yearly timer

User Manual CC DC 24 V 5A. Universal Control Unit UC-1-E. General Information SET. Universal Control Unit UC-1 Of Central Lubrication PAUSE CONTACT

TDDFM14 OWNER S MANUAL

24Hour/7Day Electronic Timeswitch

ACT 10 Digital Keypad Operating & Installation Instructions This manual is found at

SINGLE ZONE CLIMATE ZONING SYSTEM. Technical Manual. Polyaire Pty Ltd

Operating instructions Electronic preset counter Type series 717

USER & ENGINEER INSTRUCTION MANUAL

SM-10 SAT Level Meter User s Manual

DTS400B - DZS400BP 3/9/07 10:14 AM Page 1

7 DAY DIGITAL LIGHTSWITCH WITH OPTIONAL DUSK START INSTALLATION & OPERATING. Cat No. ZV700 INSTRUCTIONS

Timer Modules. MEU11 24 Hour Module, MEU17 7 Day Module (Without Housing)

2 2 Relay outputs. M DIN W72 H7mm. LE7 Weekly/Yearly timer

Complete Part Number = MIL 72A or E Followed by Suffix Code and Voltage. Example: MIL 72A STuZ-24

7 Day Digital Light Switch with Optional Dusk Start

USER MANUAL AL-Control 1 PRO

ORM0022 EHPC210 Universal Controller Operation Manual Revision 1. EHPC210 Universal Controller. Operation Manual

Transfer Switch. OTECA (Spec A) OTECB (Spec A) OTECC (Spec A) OTECD (Spec A) Amperes. English Original Instructions (Issue 5)

Installation and Operation Manual. YMP Series Signal Programmer

Radio-control universal dimmer (built-in type) Installation Instructions

TORK DGU100/DGUM100 7 DAY DIGITAL TIME SWITCH INSTALLATION AND OPERATING INSTRUCTIONS READ INSTRUCTIONS CAREFULLY BEFORE SETTING UNIT

Installation Instructions

Ambiflex MF620 USER GUIDE

Multifunction Digital Timer

Timer Modules. EL11 24 Hour Module EL17 7 Day Module. Installation & Operating Instructions

263 Series LED Bargraph Indicator and Controllers

Installation & Programming Manual. Please read before using this timer.

Comfort System T-32-P Universal Thermostat. Operation Manual

Innovative Air Systems ABN When Calling For Support Quote:.doc

Model IQ4-PC User Manual Revision Date:

Operating instructions. Universal timer switch display

Automatic Transfer Switch Control PLC Operator s Manual

TU-8A. 8 Channel Digital Timer Unit. Programming Guide

ED3. Digital Encoder Display Page 1 of 13. Description. Mechanical Drawing. Features

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01

TP7001 Range Electronic 7 Day Programmable Room Thermostat. Danfoss Heating. Installation Guide

EXTERNAL. A digital version of this document is available to download and submit online at ADDRESS POST CODE

Operations. BCU Operator Display BMTW-SVU02C-EN

F90 Series (Rate Indicators / Controllers) INSTRUCTION MANUAL

7 Day Digital Programmer 3 Channel Surface Mount

Softwired Clock. Total Lighting Control. Catalog Number: RCLK8SWS DESCRIPTION FEATURES. Installation Instructions IMRCLK8SWS 1

Schneider Industries SAS MTN5812../MTN MTN Time switch

EN Wireless programmable thermostat

s w i t c h i n g c o n t r o l l i n g c o u n t i n g

RAMMER INSTRUCTION MANUAL FITTING & OPERATING INSTRUCTIONS NEL PROGRAMMER. NSTAR Si MODELS

Inserting the batteries. Basic settings of the remote control

Troubleshooting CS800/LC900 Bikes

Preset Counters. X e. X d 6.92 X. 0. IP khz Batch. LCD Preset Counters 1, 2, 4 or 6 Presets. Multifunction. Fast and user-friendly

INSTRUCTION MANUAL HN 50. Master clock MOBATIME BE

DCL Time Controller WTDCL. Universal Lighting Technologies is a subsidiary of Panasonic Electric Works Co., Ltd., a member of the Panasonic Group

Dimming actuators GDA-4K KNX GDA-8K KNX

Preset counters, electronic

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

1 Channel Multi-Purpose Programmer User Instructions

Slimline Digital Electric Radiator. Step by Step Programming Guide

INSTRUCTIONS FOR USE Pro-Ject Tuner Box S

Dial Ezy INSTRUCTION MANUAL N IRRIGATION CONTROLLER 4 or 6 Station Model SUITABLE FOR INDOOR USE ONLY OTHERWISE WARRANTY IS VOID

Tempus Lux Digital Photoelectric Switch D GB CZ BZT Installation and operating instructions BZT27731

American DJ. Show Designer. Software Revision 2.08

Room thermostat Instructions for Use. For the user. Instructions for Use. geotherm

DIGITAL TIME SWITCH 7 DAY WITH INPUT DGU100A DGUM100A DGLC100A DGLC200A

Art M Digital codelock module

Digital Real Time Recording VCR

Softswitch128TM. SwitchingSystem. Setup and Maintenance Guide

Electronic Timer Control Day Astronomic Electronic Control

DTL-4800P. Digital Real Time Recording VCR

Radio Thermostat Clock

Low-Cost, Single-CT, Automatic Power Factor Controller for Balanced Three-Phase Reactive Power Compensation User Manual

C8000. sync interface. External sync auto format sensing : AES, Word Clock, Video Reference

Programmable Room Thermostat With RF

Electronic 2-Circuit 24-Hour Time Switch With 100-Hour Backup

Technical data. General specifications. Indicators/operating means

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

LCS-2. Low Voltage Lighting Control Relay Processing Panel. Operator s Manual

SECURITRON PRIME TIME MODEL DT-7 INSTALLATION AND OPERATING INSTRUCTIONS

VNS2210 Amplifier & Controller Installation Guide

Transcription:

Capricorn Controls Ltd Data & Application Notes Page 1 of 8 XTM72E & F Real-Time Clock Modules Originally designed to compliment our wide range of Gen-Set controls, these DC powered Real-Time-Clocks have numerous applications, spanning many industries. The XTM72E version operates in flip/flop mode only as it is purpose built for Mutual Standby applications. It has two LED s at the top marked A and B to indicate Duty Set-A or Duty Set-B is selected. Note: this unit is a direct replacement to the original XTM72A. The XTM72F version, shown opposite can be switched between normal or flip/flop modes, making it an ideal choice for general purpose applications. Note: this is a direct replacement to the original XTM72B Key Features > 24 hr, 7 day Real-Time Clock with LCD display and day of week indicator. > Internal battery backed supply provides over 150 hours reserve power to the clock. > 42 Memory locations with free formation of day blocks and separate on-off commands > Relay output with SPCO volt-free contact set > Permanent ON or OFF > Separate 12V and 24V DC inputs > DIN 72mm square module with industry standard two-piece connector. > Customised designs are available Setting the Clock without external supply Switch internal battery on, access through rear of case.. See below. Press +/- to select required settings, store using button. The display then shows Day, Date, Time with three flashing dots, relay status, winter or summer time (if previously selected) and auto. If no buttons are pressed the clock powers down after 15 minutes. Press any button to power up again. Note:- If switch 1 is set to off all clock settings will be lost. If switch-1 remains in the on position for extended periods of time without an external DC Supply, the internal battery will discharge and all clock settings could be lost. Rear accessed switches Unit supplied with both switches in the off position as shown here. Using a small screwdriver, carefully move in direction of arrow for on. Switch 1 on enables the backup battery Switch 2 on selects flip-flop mode. Switch 2 Switch 1

Capricorn Controls Ltd Data & Application Notes Page 2 of 8 Specification Operating Parameters 12Vdc Supply 9V min 16V max Burden at 12Vdc 3mA (Relay de-energised) 6mA (Relay energised) 24Vdc 20V min 32V max Burden at 24Vdc 6mA (Relay de-energised) 9mA (Relay energised) Internal Battery 3-Cell Nickel Metal- Hydride : 3.6V 70mAHr Fully charged float voltage 3.9 to 4.2V End point voltage 2.7V Trickle Charged at 2mA Life Expectancy (typical) 1000 cycles Up to 6 years at 20 deg.c Up to 3 years at 45 deg.c Relay Contact Rating 5A resistive / 30Vdc 5A AC1 / 230Vac De-rate to 700mA for inductive load Temperature -10 to +65 deg.c Operating Real-Time Clock Time-base Accuracy Shortest switching time Switching precision Language group Preset summer/winter time 32.768 KHz Crystal <1 sec / day at 20 deg.c 1 minute Accurate to the second D F GB I E NL E (EU) Fully automatic summer/winter (s/w) time change-over according to MEZ, GB, USA or freely programmable. Can alternatively be disabled Power Failure monitor to switch off switching output in case of power failure. This is indicated by three flashing dots in the display Date related vacation switching mode to interrupt the automatic program. Unit supplied with this switched off Programming Switching times memory Locations = 42 with free formation of day blocks & separate programming of ON / OFF times Pulse switching times memory Locations = 32 with free formation of day blocks & separate programming of Pulse ON / OFF times. Pulse length adjustable from 1 59 seconds. Cyclic switching times memory Locations = 16 Pulse and Pause times can be each adjusted from 1 second up to 99 minutes 59 seconds. Combination of cyclic switching, pulse switching and switching times possible.

Capricorn Controls Ltd Data & Application Notes Page 3 of 8 OFF Applications XTM72E : not intended for this application, but could be used see Flip-Flop Mode XTM72F : S2 OFF = NORMAL MODE (Not in Flip-Flop mode) General purpose applications and spanning many industries. Application Example: A system is required to operate Monday Friday, 6.00pm to 6.00am 1/ Set Dip-Switch OFF for Normal operation NOT Flip-Flop mode 2/ Program : Monday Off at 6.00am (06.00hrs) & On at 6.00pm (18.00hrs) 3/ Repeat this program for Tuesday, Wednesday & Thursday 4/ Program : Friday Off at 6.00am (06.00hrs) System Required to Run ON In normal mode, the relay changes state in line with the programmed times XTM72E : FLIP-FLOP MODE (S2 has no function) XTM72F : S2 ON for FLIP-FLOP MODE Application example: Two Generating Sets to operate in Mutual-Standby, each running 7 Days On - - 7 Days Off and duty change-over to take place at midnight each Sunday GenSet A GenSet B ON ON ON OFF OFF In Flip-Flop mode the relay changes state at each programmed transition from On to Off Thus, for the Generating Sets to changeover at mid-night every Sunday, program On/Off for 1 hour from Sat 11.00 pm (23.00 hrs) to Sat 12.00 pm (24.00 hrs). The duration of this On period is not important and could be as low as 1 minute but an hour is easier to program.

Capricorn Controls Ltd Data & Application Notes Page 4 of 8 Program mode. Note: If the entry is interrupted or finished the display reverts to true time and automatic operation within 90 sec s. It will be necessary to start program entry again if required. Repeatedly pressing Menu toggles the various setting options listed below,press ok at any time to enter required mode to change. Setting of weekly program: Press Menu button then at any time to ESCAPE program mode. If no button is pressed within 40 seconds, normal operation is resumed. Please read through the list below before programming. Basic Programming Menu Wait for free memory display to end - / + to select time on or time off - / + to set hour - / + to set minute - / + to set day (1 to 7 shown on bottom of display) to COPY to other days, ( or + then to STORE and return to NEW PROG) - / + to Add or delete days, after required days have been selected ensure Check settings. + - / + to select day then continue pressing to check all days (1 to 7 shown on bottom of display) Modify settings. - / + to select day - / + to select on or off - / + to change hour - / + to change minute to select another day escape to AUTO MODE Permanent On or Off. Permanent on. + to select PERM ON - and + briefly to cancel and revert to AUTO mode Permanent off. l Clear settings. + + to select SINGLE, ALL or END - / + to select day to clear, or + to NEXT continue until required setting is reached NEW PROG flashes + to select NEW PROG, CHECK, MODIFY, CLEAR or END Manual Override. - and + to override the current status - and + to revert back to AUTO mode Pin Code. The Time Clock can be locked against unauthorized use with a 4 digit code number. +++++ - / + to select NO PIN or WITH PIN if WITH PIN press - / + to enter first pin code digit, press, continue for all four digits To remove PIN CODE continue as above by entering your PIN CODE and select NO PIN. Unless requested, all modules are supplied with NO PIN set WARNING If a PIN CODE has been entered and is lost, the unit will have to be returned to the factory.

Capricorn Controls Ltd Data & Application Notes Page 5 of 8 Advanced Settings Random Program. This setting switches between programmed pairs (ON and OFF). The random ON and OFF times range from 10 minutes to 120 minutes. Random times always begin with the OFF period. +++ to select RANDOM Repeat as above to cancel RANDOM Dice symbol flashes continuously Start Relay Finish Holiday Program. The holiday program does NOT switch ON the set time for the period set in holiday program.start and finish is always midnight on the day that is programmed. Note a suit-case symbol flashes continuously ++++ - / + to set START year OFF - / + to set month OFF - / + to set day OFF - / + to set END year OFF - / + to set month OFF - / + to set day OFF To CHECK or CLEAR HOLIDAY mode continue as above and select the required option and repeatedly press British Summer Time. This is factory set to auto, GB/P + repeatedly 7 times until WITH S/WI is displayed - / + to select WITH SU/WI or WITHOUT SU/WI - / + to select TIME ZONE Reminder :- Time display is in 24 hour format Automatic return to Auto mode after approx 90 sec s Automatic switch to sleep mode, blanking the display after 15 mins (with not external DC Supply) Minimum switching interval is 1 minute Switching accuracy is precise-to-the-second Accuracy ± 1 sec / day at 20 C If battery switched Off, reprogramming is required. To advance time settings more quickly, press and hold - / +

Capricorn Controls Ltd Data & Application Notes Page 6 of 8 Pulse Program. Applications include : Break-time signals, ventilation systems, bell controls etc. Pulse time can be set from 1 to 59 seconds. +++ Wait for free memory display to end - / + to select NEW PROG for TIME ON or TIME OFF. On, if time clock will be off at required pulse time and viseversa. - / + to set PULS SEC on/off - / + to select hour on/off - / + to select minute on/off - / + to select day - / + to select COPY or STORE to continue to add another pulse program or to return to AUTO mode To CHECK, MODIFY or CLEAR PULSE mode continue as above and select the required option, press Cycle Program. Applications include : Process control, ventilation systems, bell controls etc. ++++ Wait for free memory display to end or press - / + to select CYCLE ON HOUR - / + to select MINUTE - / + to select DAY - / + to select PULS MINUTE On - / + to select PULS SEC On - / + to select PAUSE M Off - / + to select PAUSE S OFF - / + to select CYCLE OFF HOUR - / + to select MINUTE - / + to select DAY to continue to add another CYCLE program or to return to AUTO mode

Capricorn Controls Ltd Data & Application Notes Page 7 of 8 User Notes.

Capricorn Controls Ltd Data & Application Notes Page 8 of 8 Terminations Notes: For 12Vdc Supply, connect +Ve to Term.10 For 24Vdc Supply, connect +Ve to Term.3 Connect Supply Ve to Term.1 DO NOT connect to terminals 4, 5 or 6 as these are reserved. Relay-2 is not implemented on the standard XTM72E or XTM72F versions. Connect a Digital Voltmeter between Term.2 (+) and Term.1 (-) to check the internal battery voltage. This should read 3.6 to 3.9V and 2.7V would be fully discharged. If the voltage reads < 2.7V please contact the factory as the Battery may need to be replaced. Note : For specific information or a replacement unit - ALWAYS quote the original Serial Number Dimensions Panel cut-out = 68 x 68 72 Not to Scale All dimensions in mm. 72 85 CAPRICORN CONTROLS LIMITED INDUSTRIAL ELECTRONIC ENGINEERS SPECIALIST CONTROLS FOR ENGINE APPLICATIONS Thorpe Close, Banbury, Oxon., OX16 4SW. England Tel: +44 (0) 1295 272 360 Fax: +44 (0) 1295 264 766 Email: sales@capricorn-controls.com Web: www.capricorn-controls.com Manual-Start, Auto-Start, Start-on-Demand, Mains Failure & Mutual-Standby Controllers Annunciators and Lamp Modules. Voltage, Current, Frequency, Speed and Temperature Monitors Transport Refrigeration spares, Batteries, Battery Chargers Spares and Accessories, Customised Products and Bespoke Designs