ULTRA-VANSTAT WIRELESS PROGRAMMABLE THERMOSTAT FOR CARAVANS

Similar documents
TDDFM14 OWNER S MANUAL

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

XTM72E & F Real-Time Clock Modules

RT505TX Programmable. The RT505TX can be used with any of these receivers RXBC605 RXWBC605 RXVBC605 RXST MHz

SCS318. User Instructions. SCS318 comprising of SCS317 7 Day Wireless Programmable Room Thermostat and SSR303 Receiver

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

ST625TX Digital Room Thermostat

Radio Thermostat Clock

Programmable Room Thermostat With RF

EN Wireless programmable thermostat

24 Hour & 7 Day Digital Immersion Heater Timeswitch Article

XTM72 Exerciser Timer Module

LP20. Installation & User Guide. Dual Channel Programmer. Part number 25039DR

Operation Guide 6022 ENGLISH

1. Power supply 100, 110, 200, 220, 230 V AC (as designated), 50/60 Hz, single phase.

Sport-TIMER 3000 TM Instruction Manual

MRX1 1. Getting to know your MRX1 wireless controller

1 Channel Multi-Purpose Programmer User Instructions

EC5415B. B-Tronic EasyControl. Assembly and Operating Instructions. Wall/hand-held transmitter, 15-channel, bidirectional

Junior Max (JR Max ) Controller

Comfort System T-32-P Universal Thermostat. Operation Manual

ACT 10 Digital Keypad Operating & Installation Instructions This manual is found at

Installation & Programming Manual. Please read before using this timer.

Inserting the batteries. Basic settings of the remote control

S-Series Digital Thermostat. Instruction Manual Model No ST620RF

Waterline Room Controller - Type WLCT3

ZoneTouch V2 Zone Control System User Manual

Room thermostat Instructions for Use. For the user. Instructions for Use. geotherm

SINGLE ZONE CLIMATE ZONING SYSTEM. Technical Manual. Polyaire Pty Ltd

RAMMER INSTRUCTION MANUAL FITTING & OPERATING INSTRUCTIONS NEL PROGRAMMER. NSTAR Si MODELS

Aspect 2 Circuit Digital Scene Control

INSTALLATION, PROGRAMMING AND OPERATION MANUAL

Slimline Digital Electric Radiator. Step by Step Programming Guide

Operating instructions Through-beam sensor. OJ51xx / / 2004

talento 800 Series 365-Day One, Two and Four Circuit Electronic Time Controls Functional Description

ST9100C User Guide. Features

CP027. User Operating Instructions. Two Channel Central Heating and Hot Water Programmer

Battery Operated Controllers

VMA ACTIVE MATRIX TFT COLOR LCD MONITOR OWNER S MANUAL INSTALLATION GUIDE

ChannelPlus H17XL Series 2 User Operating Instructions

Ecomind Electricity Monitor Kit EM422EM-E-KBTS EM422EM-E-KMTS. Installation Instructions

Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual

DIGITAL TIME SWITCH 7 DAY WITH INPUT DGU100A DGUM100A DGLC100A DGLC200A

TORK DGU100/DGUM100 7 DAY DIGITAL TIME SWITCH INSTALLATION AND OPERATING INSTRUCTIONS READ INSTRUCTIONS CAREFULLY BEFORE SETTING UNIT

User Guide. Color Touchscreen Programmable Thermostat. ComfortSense Model: 13H /2017 Supersedes

STX Stairs lighting controller.

USER GUIDE for the. HES92020, HES92021, HES92220 & HES92221 DIMMER Modules

WDK-2500-STROBE. User Guide

INSTALLATION INSTRUCTIONS FOR

7 Day Digital Programmer

8 PIN PIC PROGRAMMABLE BOARD (DEVELOPMENT BOARD & PROJECT BOARD)

VMA573 and VMA or 7 Wide Screen Color LCD Monitor. Owner s Manual. Installation Guide

XTAL Bank DDS Version 0.02 Sept Preliminary, highly likely to contain numerous errors

QUARTZ TIME RECORDER. Simplex 300 OPERATION MANUAL

RD RACK MOUNT DIMMER OWNERS MANUAL VERSION /09/2011

Model 5250 Five Channel Digital to Analog Video Converter Data Pack

TIMETRAX SYNC RF WIRELESS DIGITAL CLOCK Installation Instructions

EZ Pro Jr. Installation and Programming Guide For EZ Pro TM Jr. models:

TP7001 Range Electronic 7 Day Programmable Room Thermostat. Danfoss Heating. Installation Guide

ST8-WiFi Timer. Installation Guide and Operations Manual. English MIN M D YYYY

Master Time Clock MTC Users Manual

Documentation VFD clock 8 a clock

CH1 CH2 CH3 CH4. Master /Fade CH5. 600s CH6. 60s SC1 SC2 SC4 SC3 SC5. SC6 Off/Pro. AL Fade 6 Pro. User guide

INSTALLATION INSTRUCTIONS FOR. MODEL 2230LED

TV Lift System Model CL-65 Installation Instructions

COLOUR CHANGING USB LAMP KIT

External RF programmable room thermostat 411

A6 OPERATING INSTRUCTIONS

COMPONENTS & COMPONENTS & ACCESSORIES

Safety Information. Camera System. If you back up while looking only at the monitor, you may cause damage or injury. Always back up slowly.

ServicePlus S17R Series 2 User Operating Instructions

TORK DGS180 DIGITAL SIGNAL TIMER 24 HOUR WITH DAY OMIT

7 Day Digital Programmer 3 Channel Surface Mount

How do I delete a. Remove Here

Entry Level Wind System. English Français Deutsch Nederlands Espagñol Italiano

AVE-301T AVE-301R AVE-304T AVE-308T AVE-316T

NT-9600 Wireless Barcode Scanner. Introduction

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

Entry Level Speed/Depth Display. English Français Deutsch Nederlands Espagñol Italiano

Converts any TV to Digital. MFR-300 User Guide

apple Service Source Apple Cinema HD Display 23" LCD (ADC) 11 April Apple Computer, Inc. All rights reserved.

GAUGEMASTER PRODIGY EXPRESS

Owner's Manual DIGITAL TO ANALOG BROADCAST CONVERTER WITH REMOTE CONTROL. Model: CVD508 PLEASE READ BEFORE OPERATING THIS EQUIPMENT.

SAUTER flexotron RDT405 Manual

DLP200M 2 Relay Module for Heating and Cooling Plants

Instruction Manual. 2.4G Digital Wireless Four Channel Transmitter System RVS-554W. Reverse With Confidence 1

CP017 USER OPERATING INSTRUCTIONS. Single Channel Timeswitch

QUICK START GUIDE SL-6. Powering and Wireless System for the 688 Field Production Mixer

Access Control Keypad for MK-DV, JB-DV

VITEK VTM-TLM191 VTM-TLM240

Lifestyle. Dual Channel Programmer. for heating AND hot water. Installation and User Instructions DUAL CHANNEL ISSA

The smart valve with 3 Independent programs + 2 extra modes

INSTALLATION AND OPERATING MANUAL FOR ALL MATSUKO SWITCHBOX MODELS SWB 5 SWB 5P SWB 5P+PG WARNING:

Instruction Manual Model BlockUpconverter

VT VGA TFT NEMA 4/12 Flat Panel Monitor. User s Guide

User interface. Abbreviations / Meanings

N3ZI Digital Dial Manual For kit with Backlit LCD Rev 4.00 Jan 2013 PCB

Model 5240 Digital to Analog Key Converter Data Pack

N3ZI Digital Dial Manual For kit with Serial LCD Rev 3.04 Aug 2012

Transcription:

ULTRA-VANSTAT WIRELESS PROGRAMMABLE THERMOSTAT FOR CARAVANS NOT SUPPLIED PROGRAMMER / TRANSMITTER RECEIVER THIS DOMESTIC STYLE WIRELESS 7 DAY PROGRAMMABLE HEATER CONTROL REPLACES THE TRUMA ULTRAHEAT SWITCH FITTED IN THE OLDER STYLE 60mm BOX. CONTROLS THE 230 VOLT HEATING ONLY. EASY TO INSTALL, REMOVE TWO SCREWS UNPLUG CONNECTOR, REFIT RECEIVER. CAN ALSO BE FITTED INTO ANY PANEL ADJACENT TO THE TRUMA SWITCH WITH SPACE BEHIND AND ACCESS TO THE 12 VOLT ELECTRICAL CONNECTOR. MAINTAIN A LOWER TEMPERATURE THROUGH THE NIGHT. WAKE UP TO A WARM CARAVAN / SHOWER ROOM. IDEAL FOR WINTER CARAVANING AND SEASONAL PITCHES. MICROPROCESSOR CONTROL. PROGRAM SIX DIFFERENT TIME / TEMPERATURES PER DAY. (7 DAYS) USE FOR FROST PROTECTION (PROGRAM NEEDS TO BE SET TO 5 DEGREES) EASY TO READ BLUE BACK LIT DISPLAY. Capricorn Controls Ltd, Thorpe Close, Banbury, OX16 4SW. England Tel: +44 (0) 1 295 272 360 Fax: +44 (0) 1 295 264 766 E-mail: Pump sales@capricorn-controls.com not supplied with kit. Web: www.capricorn-controls.com PLEASE DO NOT HESITATE TO CONTACT US WITH ANY ENQUIRIES

BASIC INSTALLATION INSTRUCTIONS Receiver ENSURE THE CARAVAN HEATER MAIN POWER SWITCH IS OFF.(UNPLUG MAINS LEAD TO CARAVAN) REMOVE THE TWO BLANKING CAPS FROM THE TRUMA SWITCH, IF FITTED. REMOVE THE TWO FIXING SCREWS. REMOVE REAR COVER FROM TRUMA SWITCH. A SMALL SCREW DRIVER IN THE FOUR SLOTS WILL AID REMOVAL. PIPS MAY BREAK OFF. CAREFULLY UNPLUG THE 10 WAY CONNECTOR FROM EXISTING SWITCH, DO NOT PULL WIRES. EASE LOCATING TABS TO AID REMOVAL OF CONNECTOR. FOLLOWING THE INSTRUCTION SHEET FOR THE RECEIVER REMOVE THE FRONT PLATE. SEE PAGE 5. RECONNECT THE 10 WAY CONNECTOR TO THE RECEIVER OBSERVING CORRECT ORIENTATION. FIT RECEIVER INTO BOX USING THE SPACERS PROVIDED IF REQUIRED. REFIT THE FRONT PLATE TAKING CARE THAT THE SWITCH,LED AND 5 WAY CONNECTOR ARE CORRECTLY LOCATED. PUSH THE TOP OF THE RECEIVER FULLY HOME, DO NOT ADJUST THE TOP FIXING SCREW. TO REMOVE PULL TOP OF RECEIVER TOWARDS YOU. THE RECEIVER CAN BE FITTED INTO A PANEL ADJACENT TO THE TRUMA SWITCH. A 51mm SQUARE HOLE IS REQUIRED TO BE CUT INTO PANEL. A MINIMUM OF 30mm IS REQUIRED BEHIND THE PANEL. IT COULD ALSO BE FITTED INTO A CUPBOARD, AN EXTENSION LEAD WILL BE REQUIRED. ASK FOR DETAILS. OPERATING INSTRUCTIONS FOR ADAPTED RECEIVER. PROGRAM THE TRANSMITTER TO YOUR PREFERED TIME/TEMPERATURE SETTINGS. (PRESS CENTRE OF UP/ DOWN BUTTONS) YOU MAY FIND IT EASIER WITH THE BATTERY COMPARTMENT LID OPEN FIT THE BUILT IN STAND SEE PAGE 4, STAND PROGRAMMER AT DESIRED LOCATION. REMEMBER TO PACK UNIT AWAY WHILST TRAVELLING. PROGRAMMER MAY BE SURFACE MOUNTED,REMOVE BACK PLATE, SEE PAGE 5, FIX TO SURFACE, REFIT PROGRAMMER TO BACK PLATE. SWITCH MAIN POWER SWITCH ON, WAIT FOR 2 SECONDS.IF PROGRAMMER IS NOT CALLING FOR HEAT THE RED LIGHT WILL REMAIN ON FOR APPROX. 3 MINUTES. SELECT AUTO (A) ON THE HEATER FAN CONTROL, SPEED 3. THE FAN WILL RUN VERY SLOW UNTIL TEMPERATURE BUILDS UP SO WARM AIR CAN BE CIRCULATED AROUND CARAVAN. IF YOU REQUIRE ONLY CONVECTION DO NOT SWITCH FAN ON. PRESS PUSH BUTTON TO SELECT REQUIRED HEAT OUTPUT:- YELLOW LED - 500 WATTS GREEN LED - 1000 WATTS RED LED- - - - 2000 WATTS NO LED LIT - OFF, NO HEAT SELECTED. TOP BLUE LED - CALLING FOR HEAT TOP RED LED - R/F FAILED. SEE INSTALATION # 1 SHEET PAGE 4 IF PROGRAMMER IS CALLING FOR HEAT, THE HEATER WILL OPERATE IN THE NORMAL WAY. 2

SIMPLIFIED PROGRAMMING INSTRUCTIONS ----- Transmitter unit. Within programming mode, transmitter unit will automatically resume operating after a delay of 30 seconds if no buttons are pressed. Internal setting (user adjustable) These internal settings are selective, set the Date/Clock before programming this Transmitter unit. Press and hold SET for 6 seconds to enter setting selection mode. Follow the flashing Symbols on LCD to complete following settings. Press centre of button or 1.C/F: Press or to display Fahrenheit or Centigrade. 2.Press OK to enter next setting( 24H/12H) use or buttons to select. Press OK 3.Repeat procedure by pressing OK to set Year, Month, Day, Time, Switching differential (Hysteresis) set at 1. Filter hours. Leave this at - - - - as this is not required. 4.Press Ok to complete settings. Setting the required times/temperatures into transmitter. Programming 7-d Each day of week, can be programmed separately. 1. Press SET once to enter program setting, Temp set will flash 2.Press or to set desired temperature set point for 1st program period (MORN) 3.Press Ok to enter start time for1st program Press or to set start time. Continue to set all time/temperatures for Mon (NOON, Break, EVEN, NIGHT) 4.By pressing OK after setting 1st program you can continue to program Tu, We, Th, Fr, Sa, Su. Or see Copy below. 5.When entire programming is completed, pressing Set twice and then OK programmer will start operating. Copy day settings function. 1.Press Set to enter program setting, (temp set flashing) then Press Set again. From will flash 2. Press to select the reference-day. 3. Press Ok after reference-day selected. To will flash. 4.Keep Pressing and OK to select the days of week to copy to. 5.Press OK twice, after desired days for copying are selected, programmer will now be set to RUN. OVERRIDE FUNCTION M BUTTON. Operating guide to each of the 4 modes. A. Temporary Override- Change current temperature setting until next set point. 1.Press or to adjust temperature. Temp. Set will flash. 2.Wait for 10 seconds, thermostat shall automatically run this temporary override set point. (or press OK to run this override without waiting for 10 seconds) 3.While Temporary Override is in running, Pressing OK will revert to normal settings. B. Comfort Override. Change current temperature set point to new set point for desired hours. Thermostat will resume its original Programming after Comfort Override time has ended. 1.Press M 2. Press or to adjust desired temperature. Temp. Set flashing 3. Press OK to select desired hours run time for comfort override 4.Press or to set desired hours (minimum 1 hour). 5. Press OK to run Comfort Override. 6.Press OK again will end Comfort Override. C. Permanent Hold Temperature---Hold temperature at desired set point permanently until it is cancelled. 1.Press M 2. Press M again, Temp. Set will flash. 3.Press or to set desired temperature. Permanent Hold Temp is displayed. 4. Press OK to run Permanent Hold Temperature 5.Press OK again will end Permanent Hold Temperature. D. Temperature Until (Holiday Hold)---Hold temperature at desired set point until specified date. 1.Press M 2. Press M twice again. Temp. Set will flash. 3.Press or to set desired temperature. 3. Press OK to select desired duration of Hold-Temperature Until. 4.Press or to select Month, Press OK, 5.Press or select desired DAY. 5.Press OK to run Hold Temperature Until. 6.Press OK again to end Hold Temperature Until. Reset to factory settings. Pressing OK and together for 6 seconds, Reset will appear in LCD display. Press Reset button. All previous setting shall be deleted, programming will resume its default setting. 3

THIS PAGE IS AN EXTRACT FROM THE SYSTEM ORIGINAL DATA SHEET. ULTRA-VANSTAT INSTALLATION # 1----- Fixing plug-in stand and replacing batteries Fixing the Plug-in stand on transmitter unit 1.Insert " head Screw driver into position shown above. 2.Push upward. Make sure bevel Faces down Receiver unit R/F signal lost. Led permanently on. Heating will switch off after 10 minutes if R/F transmission does not resume. Manual button. If R/F signal is lost i.e. flat batteries in transmitter, This button can be used to switch heating on or off. When signal is restored temperature is controlled by the transmitter. DO NOT LEAVE IN MANUAL MODE UNATTENDED. 3.Pull stand off back plastic housing. 5.Push down until locking tabs click into place 4.Push stand into storage groove 6.The stand is now fixed. Push stand down to remove When low battery symbol is displayed, change batteries immediately. Do not use rechargeable batteries. Open battery compartment to Access batteries. Upper compartment 2 x AAA to power transmitter. E&OE Lower compartment 2 x AAA to power back light and Transmitter. 4

THIS PAGE IS AN EXTRACT FROM THE SYSTEM ORIGINAL DATA SHEET. ULTRA-VANSTAT INSTALLATION # 2----- -RF Address- Code setting To open and close the Transmitter unit ( A flat head screwdriver will assist removal of cover) To open To close RF Address Code Setting The code (DIP Switches) is set at Capricorn Controls. This will only need to be changed if your system is in close proximity to another Ultra-Vanstat as this could cause erratic operation. 1.Insert screw-driver Into slot as shown in picture 1.Locate tabs as shown. RECEIVER 2.Gently leaver downward to loosen the back plate 2.Press firmly to close. TRANSMITTER 3.Open as shown To open and close the Receiver unit To open To close Switch both Transmitter and Receiver DIP-Switches in the same position i.e. 1 on 2 off 3 off 4 off 1.Pull the top edge of the front plate towards you. Separate the two halves taking care not to damage or move the LED and Switch 1.Place TAB into the slot on the bottom of housing Follow these instructions if the receiver is already mounted into a box or panel in the Caravan TAB 2.Ensure the LED and Switch shaft are located into holes, push forwards then ensure the 5 pin connector lines up with pins at the top of unit, push firmly home. Do not adjust the top screw, the front is held by friction 5

GENERAL INFORMATION TH-920D(TX) + RV-035610356H Programmable R/F Thermostat-pair This Programmable R/F controlled Room Thermostat-Pair consists of a mobile Transmitter Unit TH-920D(TX) and a Receiver unit RV- 0356/0356H which is designed with flush-mounting structure to fit most commercially available recessed 60 mm. boxes. A surface - mount box for installing this unit can also be used. Its installation requires no wiring between Transmitter & Receiver and can be fitted in any normal operating environment within 30 meters range between the two units. The soft Keys in the Transmitter are made of translucent rubber to allow Blue LED to project through to allow use in dim surroundings. The working frequency is marked on the top right of plastic housing on both Transmitter and Receiver. The marked frequency on both units must be consistent, or this thermostat pair will not operate. The transmitter unit is powered by 4 x AAA Alkaline batteries, 2 batteries to power the thermostat, another 2 to power the Blue backlight and transmitter. Do not use rechargeable batteries. The Receiver unit is powered from the main heater control board behind the Caravan heater, 12 volt DC. Via 10 pin connector behind the Truma switch. Overall weight of system 250grms. Technical Data Transmitter unit TH-920D (TX) 1. Power supply: 1.5 V AAA Battery x 4. Do not use rechargeable batteries. 2.Battery life: 1 year 3.Temperature reading: C/ F selectable by user. 4.Clock format: 24H/12H selectable by user. 5.Temperature sampling rate: 1 minute 6.Switching differential (Hysteresis): 0.5 C - 1.0 C / 1.0 F-2.0 F selectable by user. 7.Temperature control range: 5 35 C 6.Temperature display range : 0 50 C 9.Temperature setting: 1.0 C 10.Programming feature: 7-day 6 time/temperatures per day. 11.Shortest cycle rate protection: 3-minute, default setting deactivated. 12.Non volatile EEPROM ensure no program/setting loss 13.Temperature sensor: NTC 100K at 25 C 14.Working Frequency: (preset.not selectable by user) T433:433.92 MHZ T868: 868.35 MHZ T915:915 MHZ 15.R/F signal transmission cycle: transmits every 3 minutes. 16.Working distance : up to 30 meters 17.Dimension :110.8Wx 104 H x 21.5 D mm Receiver Unit - RV-03561RV-0356H 1. Operating power: 12 volts DC powered from heater main control board in Caravan. 2.Power consumption : 100 ma 3.Output rating: Protected driver output. 4.Storage temperature: -10 C 60 C 5.Working frequency: a-433.92mhz b-868.3smhz c-915mhz 6.Working distance : up to 30 Meters 7.lnstallation: 60 mm flush-mount 8.Dimension: 88.0 W x 88.0 H x 39.4 D mm 6

NOTES ALSO AVAILABLE FROM CAPRICORN CONTROLS.

ULTRA-VANSTAT WHILST EVERY EFFORT HAS BEEN PUT INTO THE DESIGN OF THIS 230 VOLT HEATER SYSTEM IT IS IMPOSSIBLE TO CATER FOR ALL MAKES AND MODELS OF CARAVANS. THE SYSTEM IS FLEXIBLE ENOUGH TO BE FITTED INTO A WIDE VARIETY OF CARAVANS. OUR TEAM ARE ON HAND FOR ANY HELP AND ADVICE YOU MAY NEED. PLEASE FEEL FREE TO CONTACT US AT CAPRICORN CONTROLS AND WE WILL GIVE YOU ALL THE HELP THAT WE CAN. WE ARE ALSO INTERESTED TO RECEIVE FEEDBACK INCLUDING IDEAS TO IMPROVE AND EASE INSTALLATION FOR VARIOUS CARAVANS. SPECIFIC NOTES WILL BE ADDED IN DUE COURSE. WARRANTY. Our warranty applies only if the equipment has been located, installed and maintained strictly in accordance with good engineering practice, our data sheets, operating and installation instructions and drawings. Terms and conditions of sale available upon request. LIABILITY / DISCLAIMER Capricorn Controls LTD will accept no responsibility for incorrect fitting or installation of this equipment that may cause any loss or damage whatsoever arising from any failure, use or misuse of the equipment, nor for any consequential loss arising there from. All equipment supplied has been checked by our engineers to ensure it is in full working order when it leaves our premises. We are available via email for pre-sales advise and technical assistance. Any sale is subject to our standard terms and conditions which are available on request. Capricorn Controls Ltd, Thorpe Close, Banbury, OX16 4SW. England Tel: +44 (0) 1 295 272 360 Fax: +44 (0) 1 295 264 766 E-mail: sales@capricorn-controls.com Web: www.capricorn-controls.com Please do not hesitate to contact us with any enquiries. BOOKLET ISSUE 3 E&OE 8