Art M Digital codelock module

Similar documents
Art M Digital codelock module

Art. VR4KCLM-1 - VRCLM Digital codelock

Art Stand-alone proximity reader

Art. 8KC/ G Audiokit with digital codelock

ACT 10 Digital Keypad Operating & Installation Instructions This manual is found at

1 EX5. Technical Characteristics. Dimensions

Access Control Keypad for MK-DV, JB-DV

2 CHANNEL RECEIVER DISPLAY POTENTIOMETER COM2 NC2 NO2

video door entry system - installation instructions

ImproX SupaGate 4-Channel Controller INSTALLATION MANUAL

FlexiScan. Impro FlexiScan 4-Channel Controller INSTALLATION MANUAL

M150SP USER S AND INSTALLER S MANUAL. v2.0 REV. 03/2017

TeleHawk Door entry system

ImproX (TRT) Twin Remote Terminal INSTALLATION MANUAL

Unlocking of building entrance door shall be possible by pressing the monitor's door-opener button.

PicoBoo PLUS. OPERATING MANUAL V1.1 (Sep 8, 2011) 6 Oakside Court Barrie, Ontario L4N 5V5 Tel: or

11J/SP/DDA/2W. Technical Manual VIDEX CALL. (1 Way 2 Wire DDA Video Intercom Kit)

HS-509 VIBRATION TRIP MODULE

Description Diagram Page

Timer Modules. MEU11 24 Hour Module, MEU17 7 Day Module (Without Housing)

XTM72E & F Real-Time Clock Modules

RF Wireless Receiver (Model S4PU-DC-ANT3)

Telemetry Receiver Installation Guide

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

7 Day Digital Programmer

FWD8000 Dante enabled four wire box

CR-R880-BL: Indoor/Outdoor Proximity Reader with 10cm (4in) read range

Signaling cassette KSR-32

SERIES 400 SERIES 620

CAMTO LTD. Arc detecting system DC/AC

16 Amp Electronic 24 Hour/7 Day Time Controller

ImproX (TRT) Twin Remote Terminal

DATA SHEET Panorama Rudder Indicator, TRI-2

Two (2) Channel 365 Day 24 Hr. Timer/Controllers

Operating instructions Electronic preset counter Type series 717

Model IQ4-PC User Manual Revision Date:

Model 1476-C SuperQuad HR

Pen and Multichannel Recorder: Digital Display

Standard RS232 RS ma

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

CABLE SIZE AND INSTALLATION GUIDE

STX Stairs lighting controller.

CONTROL PANEL ENGLISH INSTRUCTIONS MOTORLINE MC 2 / SEAV LRS 2150 SET

DPR100 C/D Pen and Multichannel Recorder: Digital Display

Triple RTD. On-board Digital Signal Processor. Linearization RTDs 20 Hz averaged outputs 16-bit precision comparator function.

ES-Mega MegaBeans. Access Control System. User Manual. People in Motion

Datasheet - SRB301LC 24VAC/DC

Bimetal Temperature Switch

Intelligent Security and Fire Ltd

Telemetry Receiver Installation Guide

Vorne Industries. 87/719 Analog Input Module User's Manual Industrial Drive Itasca, IL (630) Telefax (630)

SHUTTLE WITH INFRA-RED DETECTION SAS2-IR

ENGLISH (BioKey - IR Modus with Remote Control)

Overview: Specifications: Installation Instructions:

TU-8A. 8 Channel Digital Timer Unit. Programming Guide

IMPAC Infrared Thermometers

E R A I GATE OPENERS DEPARTMENT

MODEL: 40DPT. Digital Panel Meters 40 Series. [3] OPTIONS blank: none /Q: With options (specify the specification)

PT Two (2) Channel 365 Day 24 Hr. Timer/Controller

Location. Electrical. Loads. 2-wire mains-rated, 0.5 mm² to 1.5 mm² Max. length: 300 m (with 1.5 mm² cable). Example: Belden 8471.

Installation and operation manual. Art. 69AM/T Switching module for ELVOX DUE FILI (2-wire systems)

Switching Power Module

1993 Specifications CSJ , etc. SPECIAL SPECIFICATION ITEM CCTV Central Equipment

DCP100 Digital Control Programmer Specifications

A new generation of access control.

PROXIMITY SWITCHES INDUCTIVE TUBULAR SENSOR M30 SERIES HIGHLIGHTS APPLICATIONS

Operating instructions III / 2004

EA350. Generator Automatic Voltage Regulator Operation Manual

Figure 1: Standard 906 Sensor and Pulser Disc. Figure 2: Standard 906 Sensor and Pulser Wrap

Active FCB-EV-HD-SDI INTERFACE BOARD

Installer manual. RS17.P Control panel for swing gates at 24 V DC with encoder EKKO 204D

CONTRACTORS SPECIFICATION

Contactors and Contactor Assemblies

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

TAC1 Telephone Entry System

Tech Support: Customer Service: General Tech Questions: Tech Docs:

EA63-7D. Generator Automatic Voltage Regulator Operation Manual. Self Excited Automatic Voltage Regulator

Turnout Decoder TD Maxi. User Manual - version 0.1.6

M-relays, 2, 3 or 4 pole, 7-12 A Datasheet

TABLE OF CONTENTS SPECIFICATIONS...1 MOUNTING...3 WIRING...4 THEORY OF OPERATION...6 MILIVOLT INPUT OPTION JUMPER SELECTIONS...7

SECU-16. Specifications Power: Input Voltage 9-12V DC or AC Input Current Max 200mA. 8 2-wire inputs, Analog (0 5VDC) or Supervised

Indication modules. LED-indication modules. Datasheet

Installation & User Manual For. Styluscom. Wired Video Intercom System. Models StylusAB, StylusABK, StylusAS Manual Version 1.

ALM-6813/6812 INSTALLATION AND PROGRAMMING MANUAL

ED3. Digital Encoder Display Page 1 of 13. Description. Mechanical Drawing. Features

ORM0022 EHPC210 Universal Controller Operation Manual Revision 1. EHPC210 Universal Controller. Operation Manual

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

APPLICATIONS. Automatic warehouse. Trasportation lines

PRESET 10 ARCHITECTURAL OWNERS MANUAL

7 Day Digital Time Switch

Instruction Manual. Series 3000 Model R-165A. Audio/Video IF/RF Relay Panel. CATV Switching and Control

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43

Wall-/Pipe-Mount Level Indicator

ProVu PD6000 Process Meter

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

SINGLE ZONE CLIMATE ZONING SYSTEM. Technical Manual. Polyaire Pty Ltd

Radio Thermostat Clock

INSTRUCTION & OPERATION MANUAL. MODEL MMW-05 (5kW) MUROMACHI MICROWAVE FIXATION SYSTEM

M203 LG. Multiroom Planer V2.00. Introduction. New features from software V2.00

MODEL PAXLT - PAX LITE TEMPERATURE METER

Transcription:

CODELOCK UNIT MODULES Art. 4900-4900M This module has on the front a 12 stainless steel button keypad (keys from 0 to 9 plus ENTER and CLEAR keys), 2 LEDS for operation signalling, the keypad illumination LEDs and a mirror stainless steel front plate (standard version). Codelock unit module has 3 built-in relays that allow enabling up to 3 services (door-open, gate-open etc.) by typing the programmed secret codes. Acoustic and visual (green and red front LEDs) signals facilitate the use and the programming operations. This module can be used individually or combined with other modules on an audio or video door entry system. MAIN FEATURES 3 C, NC, NO relay outputs (24Vac/dc 5A max); 100 Programmable secret codes (one for each relay); Each relay can be set to be activated for a specific time (01 to Fig. 1 - Art. 4900-4900M 99 seconds) or to work as latch; Two active low inputs to command directly the relay 1 and 2; Programming menu guarded by a 4-8 digit programmable secret code; Visual and Acoustic signal during operating and programming; Keypad illumination LEDs. GENERAL DIRECTIONS FOR INSTALLATION In order to achieve the best results from the schematics described it is necessary to install only original VIDEX equipment, strictly keeping to the items indicated on each schematic and follow these General Directions for Installation: The system must be installed according to national rules in force, in any case the running of cables of any intercom unit must be carried out separately from the mains; All multipair cables should be compliant to CW1308 specification (0.5mm twisted pair telephone cable). Cables for speech line and service should have a max resistance of 10 Ohm Lock release wires should be doubled up (Lock release wires and power supply wires should have a max resistance of 3 Ohm); The cable sizes above can be used for distances up to 50m. On distances above 50m the cable sizes should be increased to keep the overall resistance of the cable below the RESISTANCES indicated above; Double check the connections before power up; Power up the system then check all functions. LOCK release BACK EMF PrOTECTION A varistor must be fitted across the terminals on AC lock release (Fig.1A) and a diode must be fitted across the terminals on a DC lock release (Fig.1B) to suppress back EMF voltages. Connect the components to the lock releases as shown in figures. VARISTOR (MOV) DIODE 1N4002 12V AC LOCK RELEASE 12V DC LOCK RELEASE Fig. 1A Fig. 1B 1

BUZZER BACK EMF When using intercoms with buzzer call (Art. 924/926, SMART1/2, 3101/2, 3001/2 and 3021/2) add one 0,1uF capacitor between terminals 6 and 3. BUILT-IN RELAYS BACK EMF PROTECTION ART. 4900M The Art. 4900M includes selectable back EMF protection on the relays. The jumpers marked MOV (One jumper for each relay) are used to select the protection type. When using a fail secure lock with connections C & NO the jumper should be in the NO position. When using a fail open lock with connections C & NC the jumper should be in the NC position and when using the codelock to trigger a gate controller or another third party controller the jumper should be removed completely (This disables the protection on the relay). PROGRAMMING (SEE ALSO THE RELEVANT FLOW CHART) Enter the MASTER CODE : first time type 8 times 1 (11111111 factory preset) and press ENTER (The red LED will illuminate); Confirm MASTER CODE (typing again the same) or type the new one (4 to 8 digits) then press ENTER (). Pressing twice the ENTER button without changing the MASTER CODE, will exit from the programming; Enter the USER NUMBER (2 digits from 00 to 99) then press ENTER (); Now you can do two different operations: 1. If you press CLEAR the code relevant to the USER NUMBER entered is deleted and the system go back to USER NUMBER entering (melody); 2. Enter the USER CODE (4 to 8 digits) then press ENTER (). The user code must be prefixed with 1 digit that specify the relay to operate: 0 relay 1 and 2, 1 relay 1, 2 relay 2 and 3 relay 3. I.E. the code 148325 would operate the relay 1 only. The system go back to USER NUMBER entering. Continue as above to delete or enter other codes or press twice ENTER to jump to next programming step (); Enter the RELAY 1 operation time (2 digits 01 to 99 I.E. 05=5 seconds, 00= remain open time) or leave the existing time then press ENTER (); Enter the RELAY 2 operation time (2 digits 01 to 99 I.E. 05=5 seconds, 00= remain open time) or leave the existing time then press ENTER (); Enter the RELAY 3 operation time (2 digits 01 to 99 I.E. 05=5 seconds, 00= remain open time) or leave the existing time then press ENTER (); The system is ready to use (the red LED will be off). PROGRAMMING NOTES After the confirmation of an entered data by pressing the ENTER button, by pressing twice the same button you can exit from the programming. RETURN SYSTEM TO PRESET MASTER FACTORY CODE Turn off power to code lock; Keep ENTER button pressed while turning back on the power; Release ENTER button; The master code is now set at 11111111 (eight times one). OPERATION Type in the programmed code and press ENTER ; If the code is right, the green LED will illuminate and the relay will operate for the programmed time; If a wrong code is ENTER ed, a continuous melody will sound for 4 or more seconds, according to the number of mistakes; To switch off any relay while operating, type in the relevant code then press the CLEAR button. OPERATION NOTES To operate relays together, set the same code for each relay; If a wrong code is entered, the system will lock out for 5 seconds which will increase each time a wrong code is entered. The system will operate only when the correct code is entered. TERMINALS: SW2 Relay 2 command signal (active low) SW1 Relay 1 command signal (active low) NC3 Relay 3 normally closed contact NO3 Relay 3 normally open contact C3 Relay 3 common contact NC2 Relay 2 normally closed contact NO2 Relay 2 normally open contact C2 Relay 2 common contact NC1 Relay 1 normally closed contact NO1 Relay 1 normally open contact C1 Relay 1 common contact + 12/24Vac/dc power input 2

TECHNICAL SPECIFICATION Power Supply: 12/24 Vac/dc Power Consumption: 2A 30mA max Working Temperature: -10 +50 C PROGRAMMING FLOW-CHART Red LED will be ON ENTER MASTER CODE CONFIRM OR CHANGE MASTER CODE PRESS CLEAR TO DELETE THE USER RELEVANT CODE ENTER USER NUMBER OTHER CODES? ENTER USER CODE AND PRESS ENTER YES First time 8 times 1 "11111111" factory preset Type again eight times 1 or the new code 4 to 8 digits 2 digits (from 00 to 99) IMPORTANT: 4 to 8 digits. Code must be prefixed with relay number. 0 = relay 1 and 2; 1 = relay 1; 2 = relay 2; 3 = relay 3. I.E. code 148325 would operate Relay 1 only. Red LED will be OFF NO PRESS ENTER TWICE ENTER RELAY 1 TIME ENTER RELAY 2 TIME ENTER RELAY 3 TIME SYSTEM READY TO USE 2 digits (01-99) I.E. 05 = 5 seconds 00 = remain open time 2 digits (01-99) I.E. 05 = 5 seconds 00 = remain open time 2 digits (01-99) I.E. 05 = 5 seconds 00 = remain open time COSTUMEr SUPPOrT All Countries: VIDEX ELECTrONICS S.P.A. www.videx.it - technical@videx.it Tel: +39 0734-631669 Fax: +39 0734-632475 UK Customers: VIDEX SECUrITY LTD www.videx-security.com Tech Line: 0191 224 3174 Fax: 0191 224 1559 3 The product is CE marked demonstrating its conformity and is for distribution within all member states of the EU with no restrictions. This product follows the provisions of the European Directives 2004/108/ECC (EMC); 2006/95/ECC (LVD) and 93/68/ECC (CE marking).

DATA LIST CODE STORED INTO MEMORY 4

5

6

7

8