% & ) ANSI Accredited Program

Size: px
Start display at page:

Download "% & ) ANSI Accredited Program"

Transcription

1 PROUT RTIITION Pilot Operated Water onditioning & Purification Valves omposite ody to 2-WY pplications Water purification, conditioning and distribution in commercial/ industrial markets with reverse osmosis systems. Reverse osmosis systems are found in several drinking water applications including restaurants, food and beverage equipment, and grocery store vegetable misting. eatures omposite body valve 2-way, normally closed and normally open asn TM connection system available in: Turn & Lock NPT thread Solvent bond Tested and certified by NS International UL and S recognized coils Mountable in any position, upright preferred Manual override available on all normally closed constructions onstruction ody ore Tube / onnet ore and Plugnut Springs Seals and isc Shading oil lectrical Standard oil and lass of Insulation Valve Parts in ontact with luids omposite, ngineered Plastic (PP) Stainless Steel Stainless Steel Stainless Steel PM, TP opper Watt Rating and Power consumption Spare coil amily Watts Watts V Holding V Inrush onnection Type Normally losed onduit Leaded IN Normally Open onduit Leaded IN Standard Voltages: : 24/60, 120/60, 240/60. : 12 and 24. Must be specified when ordering, see How to Order hart. Solenoid nclosures onduit Hub Open rame (Leaded) 18" lead IN (11 mm orm ) Watertight IP 65 when used with IN connector kit for S coils (see kits below). Kits emale IN connector kit for coils * NPT conduit hub kit for leaded coils * (Kits contains 10 pcs of each: connector, gasket, and attaching screw.) Mounting bracket kit = Kits for end connection nd onnection Type Kit Numbers NPT Thread onnector kit M M M M Solvent ond onnector kit M M M M Turn & Lock onnector kit M M M M % & ) NSI ccredited Program asn onnection System (See Ordering Page) Solvent ond - PV tubing NPT Thread - NPT pipe Turn & Lock - opper (TS) - PX tubing Nominal mbient Temp. Ranges Normally losed &, Normally Open : 32 to 120 (0 to 49 ) Normally Open : 32 to 100 (0 to 38 ) pprovals UL recognized coil ile * S certified coil see S file No * Meets applicable directives. Tested and certified by NS International: NS 61-G: rinking Water System omponents (includes Lead ree requirements) NS 169: Special Purpose ood quipment and evices NS 42 : rinking Water Treatment Units Material and Structural Integrity Requirements NS 372: rinking Water System omponents Lead ontent ertification The NS ertification Program is accredited by the Standards ouncil of anada and NSI. *or UL & S approvals on NO coils, please consult SO. 17

2 2-WY Specifications (nglish units) Orifice asn nd onnections System RINKING WTR VRSION: NS 61-G, 169, 42 v low actor Min Operating Pressure ifferential (psi) Max. Max. Max. luid Wattage Temp. atalog Number General Service - Normally losed 3/8 5/8 NPT thread / NPT thread /8 5/8 NPT thread / Solvent ond * /8 5/8 NPT thread / Turn & Lock /8 5/8 Turn & Lock / Turn & Lock K /8 5/8 Turn & Lock / Solvent bond * K /8 5/8 Solvent bond / Solvent bond * W /2 3/4 NPT thread / NPT thread /2 3/4 NPT thread / Solvent ond * /2 3/4 NPT thread / Turn & Lock /2 3/4 Turn & Lock / Turn & Lock K /2 3/4 Turn & Lock / Solvent bond * K /2 3/4 Solvent bond / Solvent bond * W /4 3/4 NPT thread / NPT thread /4 3/4 NPT thread / Solvent ond * /4 3/4 NPT thread / Turn & Lock /4 3/4 Turn & Lock / Turn & Lock K /4 3/4 Turn & Lock / Solvent bond * K /4 3/4 Solvent bond / Solvent bond * W NPT thread / NPT thread NPT thread / Solvent ond * NPT thread / Turn & Lock Turn & Lock / Turn & Lock K Turn & Lock / Solvent bond * K Solvent bond / Solvent bond * W General Service - Normally Open 3/8 5/8 NPT thread / NPT thread /8 5/8 NPT thread / Solvent ond * /8 5/8 NPT thread / Turn & Lock /8 5/8 Turn & Lock / Turn & Lock K /8 5/8 Turn & Lock / Solvent bond * K /8 5/8 Solvent bond / Solvent bond * W /2 3/4 NPT thread / NPT thread /2 3/4 NPT thread / Solvent ond * /2 3/4 NPT thread / Turn & Lock /2 3/4 Turn & Lock / Turn & Lock K /2 3/4 Turn & Lock / Solvent bond * K /2 3/4 Solvent bond / Solvent bond * W /4 3/4 NPT thread / NPT thread /4 3/4 NPT thread / Solvent ond * /4 3/4 NPT thread / Turn & Lock /4 3/4 Turn & Lock / Turn & Lock K /4 3/4 Turn & Lock / Solvent bond * K /4 3/4 Solvent bond / Solvent bond * W NPT thread / NPT thread NPT thread / Solvent ond * NPT thread / Turn & Lock Turn & Lock / Turn & Lock K Turn & Lock / Solvent bond * K Solvent bond / Solvent bond * W Prevent from freezing. Manual Override is available for all Normally losed constructions. See How to Order section for ordering details. *Limitation on fluid temperature for PV tubing for NS 61-G is 73 and for NS 372 is

3 2-WY Specifications (nglish units) Orifice asn v low nd onnections System actor L R VRSION - NS 372 Lead content certification Min Operating Pressure ifferential (psi) Max. Max. Max. luid Wattage Temp. atalog Number General Service - Normally losed 3/8 5/8 NPT thread / NPT thread /8 5/8 NPT thread / Solvent ond * /8 5/8 NPT thread / Turn & Lock /8 5/8 Turn & Lock / Turn & Lock K /8 5/8 Turn & Lock / Solvent bond * K /8 5/8 Solvent bond / Solvent bond * W /2 3/4 NPT thread / NPT thread /2 3/4 NPT thread / Solvent ond * /2 3/4 NPT thread / Turn & Lock /2 3/4 Turn & Lock / Turn & Lock K /2 3/4 Turn & Lock / Solvent bond * K /2 3/4 Solvent bond / Solvent bond * W /4 3/4 NPT thread / NPT thread /4 3/4 NPT thread / Solvent ond * /4 3/4 NPT thread / Turn & Lock /4 3/4 Turn & Lock / Turn & Lock K /4 3/4 Turn & Lock / Solvent bond * K /4 3/4 Solvent bond / Solvent bond * W NPT thread / NPT thread NPT thread / Solvent ond * NPT thread / Turn & Lock Turn & Lock / Turn & Lock K Turn & Lock / Solvent bond * K Solvent bond / Solvent bond * W General Service - Normally Open 3/8 5/8 NPT thread / NPT thread /8 5/8 NPT thread / Solvent ond * /8 5/8 NPT thread / Turn & Lock /8 5/8 Turn & Lock / Turn & Lock K /8 5/8 Turn & Lock / Solvent bond * K /8 5/8 Solvent bond / Solvent bond * W /2 3/4 NPT thread / NPT thread /2 3/4 NPT thread / Solvent ond * /2 3/4 NPT thread / Turn & Lock /2 3/4 Turn & Lock / Turn & Lock K /2 3/4 Turn & Lock / Solvent bond * K /2 3/4 Solvent bond / Solvent bond * W /4 3/4 NPT thread / NPT thread /4 3/4 NPT thread / Solvent ond * /4 3/4 NPT thread / Turn & Lock /4 3/4 Turn & Lock / Turn & Lock K /4 3/4 Turn & Lock / Solvent bond * K /4 3/4 Solvent bond / Solvent bond * W NPT thread / NPT thread NPT thread / Solvent ond * NPT thread / Turn & Lock Turn & Lock / Turn & Lock K Turn & Lock / Solvent bond * K Solvent bond / Solvent bond * W Prevent from freezing. Manual Override is available for all Normally losed constructions. See How to Order section for ordering details. *Limitation on fluid temperature for PV tubing for NS 61-G is 73 and for NS 372 is

4 2-WY Specifications (Metric units) Orifice (mm) asn nd onnections System RINKING WTR VRSION: NS 61-G, 169, 42 Kv low actor (m 3 /hr) Min Operating Pressure ifferential (bar) Max. Max. Max. luid Wattage Temp. atalog Number General Service - Normally losed 3/8 15 NPT thread / NPT thread /8 15 NPT thread / Solvent ond * /8 15 NPT thread / Turn & Lock /8 15 Turn & Lock / Turn & Lock K /8 15 Turn & Lock / Solvent bond * K /8 15 Solvent bond / Solvent bond * W /2 19 NPT thread / NPT thread /2 19 NPT thread / Solvent ond * /2 19 NPT thread / Turn & Lock /2 19 Turn & Lock / Turn & Lock K /2 19 Turn & Lock / Solvent bond * K /2 19 Solvent bond / Solvent bond * W /4 19 NPT thread / NPT thread /4 19 NPT thread / Solvent ond * /4 19 NPT thread / Turn & Lock /4 19 Turn & Lock / Turn & Lock K /4 19 Turn & Lock / Solvent bond * K /4 19 Solvent bond / Solvent bond * W NPT thread / NPT thread NPT thread / Solvent ond * NPT thread / Turn & Lock Turn & Lock / Turn & Lock K Turn & Lock / Solvent bond * K Solvent bond / Solvent bond * W General Service - Normally Open 3/8 15 NPT thread / NPT thread /8 15 NPT thread / Solvent ond * /8 15 NPT thread / Turn & Lock /8 15 Turn & Lock / Turn & Lock K /8 15 Turn & Lock / Solvent bond * K /8 15 Solvent bond / Solvent bond * W /2 19 NPT thread / NPT thread /2 19 NPT thread / Solvent ond * /2 19 NPT thread / Turn & Lock /2 19 Turn & Lock / Turn & Lock K /2 19 Turn & Lock / Solvent bond * K /2 19 Solvent bond / Solvent bond * W /4 19 NPT thread / NPT thread /4 19 NPT thread / Solvent ond * /4 19 NPT thread / Turn & Lock /4 19 Turn & Lock / Turn & Lock K /4 19 Turn & Lock / Solvent bond * K /4 19 Solvent bond / Solvent bond * W NPT thread / NPT thread NPT thread / Solvent ond * NPT thread / Turn & Lock Turn & Lock / Turn & Lock K Turn & Lock / Solvent bond * K Solvent bond / Solvent bond * W Prevent from freezing. Manual Override is available for all Normally losed constructions. See How to Order section for ordering details. *Limitation on fluid temperature for PV tubing for NS 61-G is 22.7 and for NS 372 is 50 20

5 2-WY Specifications (Metric units) Orifice (mm) asn nd onnections System Kv low actor (m 3 /hr) L R VRSION - NS 372 Lead content certification Min Operating Pressure ifferential (bar) Max. Max. Max. luid Wattage Temp. atalog Number General Service - Normally losed 3/8 15 NPT thread / NPT thread /8 15 NPT thread / Solvent ond * /8 15 NPT thread / Turn & Lock /8 15 Turn & Lock / Turn & Lock K /8 15 Turn & Lock / Solvent bond * K /8 15 Solvent bond / Solvent bond * W /2 19 NPT thread / NPT thread /2 19 NPT thread / Solvent ond * /2 19 NPT thread / Turn & Lock /2 19 Turn & Lock / Turn & Lock K /2 19 Turn & Lock / Solvent bond * K /2 19 Solvent bond / Solvent bond * W /4 19 NPT thread / NPT thread /4 19 NPT thread / Solvent ond * /4 19 NPT thread / Turn & Lock /4 19 Turn & Lock / Turn & Lock K /4 19 Turn & Lock / Solvent bond * K /4 19 Solvent bond / Solvent bond * W NPT thread / NPT thread NPT thread / Solvent ond * NPT thread / Turn & Lock Turn & Lock / Turn & Lock K Turn & Lock / Solvent bond * K Solvent bond / Solvent bond * W General Service - Normally Open 3/8 15 NPT thread / NPT thread /8 15 NPT thread / Solvent ond * /8 15 NPT thread / Turn & Lock /8 15 Turn & Lock / Turn & Lock K /8 15 Turn & Lock / Solvent bond * K /8 15 Solvent bond / Solvent bond * W /2 19 NPT thread / NPT thread /2 19 NPT thread / Solvent ond * /2 19 NPT thread / Turn & Lock /2 19 Turn & Lock / Turn & Lock K /2 19 Turn & Lock / Solvent bond * K /2 19 Solvent bond / Solvent bond * W /4 19 NPT thread / NPT thread /4 19 NPT thread / Solvent ond * /4 19 NPT thread / Turn & Lock /4 19 Turn & Lock / Turn & Lock K /4 19 Turn & Lock / Solvent bond * K /4 19 Solvent bond / Solvent bond * W NPT thread / NPT thread NPT thread / Solvent ond * NPT thread / Turn & Lock Turn & Lock / Turn & Lock K Turn & Lock / Solvent bond * K Solvent bond / Solvent bond * W Prevent from freezing. Manual Override is available for all Normally losed constructions. See How to Order section for ordering details. *Limitation on fluid temperature for PV tubing for NS 61-G is 22.7 and for NS 372 is 50 21

6 2-WY How to Order asn nd onnection 8 NPT K Turn & Lock W Solvent ond S Valve esignation Refer to the Specifications Section oil lectrical onnection S0 IN Type coil without connector L0 Leaded coil L1 Leaded coil with 1/2 NPT threaded conduit adaptor imensions: inches (mm) Pressure Vessel Options 100 No options 101 Manual Override (stainless steel) 200 Mounting racket (stainless steel) 201 Manual Override with Mounting racket Voltages, for normally closed 4 24V, 60 Hz 0 120V, 60 Hz; 110V, 50 Hz 6 240V, 60 Hz; 220V 50 Hz, for normally open 4 24V, 60 Hz 2 120V, 60 Hz 240V, 60 Hz, for both normally open and normally closed 3 12V 1 24V in mm in mm & NPT ONNTOR WITH ONUIT HU ONNTOR [27.6] 1.1 [28] NPT ONUIT HU ONNTOR SRW M3 X 12 (IN-84) NPT ONNTOR in mm in mm [27.6] & NPT ONNTOR WITH ONUIT HU ONNTOR 1.1 [28] NPT ONUIT HU ONNTOR SRW M3 X 12 (IN-84) NPT ONNTOR 22

7 2-WY imensions: inches (mm) & TURN & LOK ONNTION WITH IN ONNTION in mm in mm [17].5 [12] [22] TURN &LOK ONNTOR in mm in mm [17] & TURN & LOK ONNTION WITH IN ONNTION.5 [12] [22] TURN & LOK ONNTOR in mm in mm & SOLVNT ON ONNTION WITH L WIR ONNTION.7 [17].5 [12] [22] SOLVNT ON ONNTOR 3 23

8 2-WY S imensions: inches (mm) in mm in mm & SOLVNT ON ONNTION WITH L WIR ONNTION.7 [17].5 [12] [22] SOLVNT ON ONNTOR G H I J in mm in mm in mm in mm SHOWN WITH OPTIONL MOUNTING RKT OR VLVS WITH NY N ONNTOR through VLVS H VLVS -- H G J 2X [24] 2.0 2X [52] I 1 [35] 1 [35] SHOWN WITH OPTIONL MNUL OVRRI OR VLVS WITH NY N ONNTOR in mm in mm in mm in mm MNUL OVRRI 24

RCA3 SOLENOID PILOT VALVES PENTAIR CLEAN AIR SYSTEMS

RCA3 SOLENOID PILOT VALVES PENTAIR CLEAN AIR SYSTEMS RCA3 SOLENOID S PENTAIR CLEAN AIR SYSTEMS GOYEN RCA3D REMOTE PILOT Remote solenoid pilot valve to control the actuation of dust collector diaphragm valves. RCA3D with flying lead connection INSTALLATION

More information

Modular Lube Lubrication Systems System Controls

Modular Lube Lubrication Systems System Controls Model 84501 Program Timer Solid State Designed to control the lubrication cycle frequency of air-operated single-stroke pumps. Timer turns pump on/off at programmed intervals via a 3-way or 4-way air solenoid

More information

82540/ /2-way diaphragm valves

82540/ /2-way diaphragm valves > > ort size: DN 8... 50, 1/4... 2 (ISO G/NT) > > Valve operates without differential pressure > > High flow rate > > For robust industry solutions > > Damped operation > > Suitable for vacuum > > Solenoid

More information

Pilot Valves and Nema 4 Enclosures. Innovative Environmental Solutions

Pilot Valves and Nema 4 Enclosures. Innovative Environmental Solutions Pilot Valves and Nema 4 Enclosures Innovative Environmental Solutions Technical Specification Q Series Solenoid Solenoid used in the remote or integral actuation of dust collector diaphragm or pilot valves.

More information

Introduction. Pressure Gauges (analogue/digital) Pressure Gauges (analogue/digital) and Accessories.

Introduction. Pressure Gauges (analogue/digital) Pressure Gauges (analogue/digital) and Accessories. Pressure auges (analogue/digital) Introduction Pressure auges (analogue/digital) and Accessories Measuring pressure on equipment is indispensable for monitoring and ensuring the smooth functioning and

More information

GOYEN PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS CLEAN AIR SOLUTIONS PRODUCT LEAFLET

GOYEN PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS CLEAN AIR SOLUTIONS PRODUCT LEAFLET PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS CLEAN AIR SOLUTIONS 3-6VFD COMBINATION FLAME AND DUST IGNITION PROOF ENCLOSURES Goyen pilot valve enclosures for hazardous locations are available in a combination

More information

Solenoid valves VZWD, directly actuated

Solenoid valves VZWD, directly actuated 2015/12 Subject to change Internet: www.festo.com/catalogue/... 1 Key features and overview General Directly actuated solenoid valves VZWD are mainly intended for applications with high pressure ranges

More information

XML LED X M L L E D. Explosionproof Linear LED Lighting

XML LED X M L L E D. Explosionproof Linear LED Lighting LED Class I, Division 1, Groups C & D Class I, Division 2, Groups C & D Class II, Division 1, Groups E, F & G Class III Simultaneous Presence UL 844 Hazardous Locations IEC Ex d Zone 1 Equivalent UL 924

More information

Mechanical flow switch for On/Off control

Mechanical flow switch for On/Off control Mechanical flow switch for On/Off control Economic integration in pipe systems without any additional piping Magnetic measuring principle Mechanical adjustment of setpoint Type 8010 can be combined with...

More information

PILOT VALVES AND NEMA 4 ENCLOSURES PENTAIR ENVIRONMENTAL SYSTEMS

PILOT VALVES AND NEMA 4 ENCLOSURES PENTAIR ENVIRONMENTAL SYSTEMS PILOT VALVES AND NEMA 4 ENCLOSURES PENTAIR ENVIRONMENTAL SYSTEMS Q SERIES SOLENOID Solenoid used in the remote or integral actuation of dust collector diaphragm or pilot valves. Flying leads, QF INSTALLATION

More information

Pendant Light Fitting IEC Series 6470/2

Pendant Light Fitting IEC Series 6470/2 > Available light sources high-pressure sodium lamps (HSE) metal halide lamps (HIE) halogen lamps (QT) > Versatile mounting methods > Enclosure made of saltwater-resistant aluminium www.stahl.de 11435E

More information

Single Point Flow Monitor SW118 SW119

Single Point Flow Monitor SW118 SW119 SW8 SW9 SW8 SW9 Single point flow monitors with MIN/MAX monitoring function, suitable for water, oil, air and media with similar thermal conductivities (selectable by means of a medium switch). With either

More information

PROPORTIONAL VALVES Sentronic plus

PROPORTIONAL VALVES Sentronic plus 04GB-06/R0 PROPORTIONAL VALVES Sentronic plus with external pressure supply G / FEATURES Sentronic plus is a highly dynamical -way proportional valve with digital control. Sentronic plus stands for: Digital

More information

Solenoid valves VZWD, directly actuated

Solenoid valves VZWD, directly actuated q/w Worldwide: Superb: Easy: Festo core product range Covers 80% of your automation tasks Always in stock Festo quality at an attractive price Reduces procurement and storing complexity qready for dispatch

More information

EZ-LIGHT K90FDL Daylight Visible

EZ-LIGHT K90FDL Daylight Visible Datasheet Large one to five color daylight visible indicator with flashing input control Intense levels of light output for areas with high ambient light - even outdoors All models have flashing input

More information

Signet 2250 Hydrostatic Level Sensor

Signet 2250 Hydrostatic Level Sensor Signet 2250 Hydrostatic Sensor *32250.090* 32250.090 Rev. A 10/06 English English Safety Instructions 1. Prior to installation or removal: Depressurize and vent system Drain below sensor level 2. Confi

More information

WLB SERIES HID Lighting for Hose Down Applications

WLB SERIES HID Lighting for Hose Down Applications WLB SERIES W LB HID Lighting for Hose Down Applications Class II, Division 2, Groups F & G Class III UL 844 Hazardous Locations UL 1598 Wet Locations NEMA 4X NSF Certified Food Equipment CUL Heavy Hose

More information

Dewatering. Series description Wilo-Drain STS 65. Submersible sewage pump

Dewatering. Series description Wilo-Drain STS 65. Submersible sewage pump Series description Wilo-Drain STS 65 Thermal winding monitoring Max. fluid temperature: 3-40 C Cable length: 10 m Free ball passage: 65 mm Max. immersion depth: 10 m Equipment/function Thermal motor monitoring

More information

3/2-directional valve, electrically operated, Series AS3-SOV G 3/8 - G 1/2 pipe connection ATEX optional

3/2-directional valve, electrically operated, Series AS3-SOV G 3/8 - G 1/2 pipe connection ATEX optional Preparation of compressed air Maintenance units and components 1 IM0046156 Version Poppet valve, Can be assembled into blocks Nominal flow 4500 l/min Nominal flow, 1 2 4500 l/min Nominal flow, 2 3 3200

More information

YVAA Air-cooled VSD screw chiller

YVAA Air-cooled VSD screw chiller YV ir-cooled VS screw chiller ooling capacities from 569 kw to 1654 kw t urovent Standard onditions this equipment meets lass energy efficiency levels. ompatible range ote: this picture is showing aesthetics

More information

Basic & Safe. Industrial plugs and sockets

Basic & Safe. Industrial plugs and sockets asic & Safe Industrial plugs and sockets Screwless terminal connectors Highly reliable and safe products Easy to install thanks to clear terminal marking Resistant against vibrations and heat fluctuations

More information

Nessie Coils for VDH and VDHT valves

Nessie Coils for VDH and VDHT valves Data Sheet Nessie Coils for VDH and VDHT valves Introduction The coils for the Danfoss High-Pressure Systems valves are high-performance and reliable coils based on more than 50 years manufacturing of

More information

WFH SERIES Fluorescent High-Bay Lighting for Hazardous Locations

WFH SERIES Fluorescent High-Bay Lighting for Hazardous Locations WFH SERIES W FH Fluorescent High-Bay Lighting for Hazardous Locations Class I, Division 2, Groups A, B, C, & D Class II, Division 2, Groups F & G Class III UL Listed for Wet & Hazardous Locations CUL Listed

More information

SQM40/41 Actuators for air and gas dampers

SQM40/41 Actuators for air and gas dampers SQM40/41 Actuators for air and gas dampers Description SQM40/41 actuators are used for the positioning of flow control valves, butterfly valves, dampers or any application requiring rotary motion. The

More information

EZ-LIGHT S18L General Purpose Indicators Controlled Access, Inc. orders this part as S18DLGRYPQ

EZ-LIGHT S18L General Purpose Indicators Controlled Access, Inc. orders this part as S18DLGRYPQ EZ-LIGHT S8L General Purpose Indicators ontrolled ccess, Inc. orders this part as S8DLGRYPQ Datasheet D-Operated LED Indicators with One, Two, or Three olors Up to three independent colors in one unit

More information

Water Rotary Unions. 100th. Special Design Features BARCO

Water Rotary Unions. 100th. Special Design Features BARCO BARCO BULLETIN RS 3100 BARCO SERIES E-75 RS Water Rotary s BARCO 1908 2008 100th ANNIVERSARY CARY, IL Special Design Features Dry run capability. Silicon carbide to carbon graphite mechanical seals. For

More information

EXLUX ECOLUX 6480 Series

EXLUX ECOLUX 6480 Series EXLUX ECOLUX 6480 Series L I G H T I N G 6000 6008 6400 6408 6600 6608 6480 Explosion Protected Fluorescent Luminaires for Hazardous and Corrosive Applications Features: Electronic Ballasts For Fluorescent

More information

Part-Turn Electric Multi-Turn Electric

Part-Turn Electric Multi-Turn Electric Optional 7 Handwheel Available NEMA 4 Enclosure Approvals MAR s Only (Canadian Standard Association) Enclosure NEMA 7 Enclosure Approvals MAR s Only (Canadian Standard Association) Class I, Divisions 1

More information

TEK-LCD 7801A. NEMA 4X Loop-Powered Feet and Inches Level Meter. ACCESSORIES. Technology Solutions

TEK-LCD 7801A. NEMA 4X Loop-Powered Feet and Inches Level Meter.   ACCESSORIES. Technology Solutions Technology Solutions TEK-LCD 7801A NEMA 4X Loop-Powered Feet and Inches Level Meter ACCESSORIES www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction The

More information

40 micron filter element standard, 5 micron available. Metal bowl with sight gauge standard. Twist drain as standard, optional auto drain.

40 micron filter element standard, 5 micron available. Metal bowl with sight gauge standard. Twist drain as standard, optional auto drain. atalog 7P-6 Hi-low 6 Series Prep-ir II, 6 Series / & Inch Ports 6 ilters Hi-low utomatic eatures xcellent water removal efficiency or heavy duty applications with minimum pressure drop requirement. Unique

More information

WCHE BTU/Hr Watts

WCHE BTU/Hr Watts 763.576.3200 SPEC-00754 F763.422.2211 THERMAL MANAGEMENT SEALED ENCLOSURE COOLING HEAT EXCHANGERS Sealed Enclosure Cooling Heat Exchangers CLIMAGUARD AIR-TO-WATER INDOOR WCHE01 2968 BTU/Hr. 870 Watts WCHE04/WCHE06

More information

LPUM - Local Power Unit General. Product Data Sheet January 2013 SD E06

LPUM - Local Power Unit General. Product Data Sheet January 2013 SD E06 LPUM - Local Power Unit General Product Data Sheet January 2013 SD 1520-0E06 TM LPUM - Local Power Unit January 2013 Description The LPUM - (Local Power Unit) - is an integrated electro-hydraulic system

More information

EXLUX ECOLUX C-LUX 6480 Series

EXLUX ECOLUX C-LUX 6480 Series EXLUX ECOLUX C-LUX 6480 Series 6000 6008 6400 6408 6600 6608 6500 6480 Explosion Protected Fluorescent Luminaires for Hazardous and Corrosive Applications Features: Electronic Ballasts For Fluorescent

More information

Contactors. Agency approvals. UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B

Contactors. Agency approvals. UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B Contactors Applications Type DP provide high performance with flexibility and reliability, designed to match numerous applications including: Motors Power supplies Food service equipment Compressors Business

More information

AC diagonal module Ø 200 mm

AC diagonal module Ø 200 mm max. 850 m /h C diagonal module Ø 00 mm Material: Housing: Plastic P Support bracket: Plastic P Impeller: Plastic P Rotor: Coated in black Number of blades: 7 Direction of air flow: "V" Direction of rotation:

More information

Features. Specifications. Finish. Notes

Features. Specifications. Finish. Notes Spec-00732 BPH FX ( McLean Electronics Cooling Sealed Enclosure Cooling McLean Electronics Cooling: Sealed Enclosure Cooling SPECTRACOOL Narrow Indoor/Outdoor N43 11000 BTU/Hr. 3223 Watt N36 / BTU/Hr.

More information

Agency approvals UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B

Agency approvals UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B 11 Applications Type DP provide high performance with flexibility and reliability, designed to match numerous applications including: Motors Power supplies Food service equipment Compressors Business machines

More information

Magnetic Drive Pumps. 180 Hines Ave. Bellville, OH PH: FAX:

Magnetic Drive Pumps. 180 Hines Ave. Bellville, OH PH: FAX: Operation is similar to standard centrifugal pumps, except the impeller is driven with a magnetic coupling, eliminating the need for a shaft seal. Magnetic drive pumps must be used where flooded suction

More information

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43 Overview The MAG 6000 I/I Ex d transmitter is designed for the demands in the process industry. The robust die cast aluminium housing provides superb protection, even in the most harsh industrial environments.

More information

RA / Functional description 1/8. 4/3-, 4/2- and 3/2 Directional Control Valves Model WE 6.. /E, Series 6X with wet pin AC or DC solenoids

RA / Functional description 1/8. 4/3-, 4/2- and 3/2 Directional Control Valves Model WE 6.. /E, Series 6X with wet pin AC or DC solenoids 4/-, 4/- and / Directional Control Valves Model WE 6.. /E, Series 6X with wet pin C or DC solenoids Size 6 (D 0) up to 50 SI (50 ar) up to 1 GM (80 L/min) R 178/06.98 R 178/06.98 Replaces: 0.96 Features:

More information

Metric Series. PXM409 Differential Series. mv/v, 0 to 5 or 0 to 10 Vdc, or 4 to 20 ma Outputs Uni-Directional Ranges 0-25 mbar to 0-70 bar

Metric Series. PXM409 Differential Series. mv/v, 0 to 5 or 0 to 10 Vdc, or 4 to 20 ma Outputs Uni-Directional Ranges 0-25 mbar to 0-70 bar Micro-Machined Silicon Transducers wet/dry differential mv/v, 0 to 5 or 0 to 10 Vdc, or 4 to 20 ma Outputs Uni-Directional Ranges 0-25 mbar to 0-70 bar PXM409 Differential Series U 5-Point NIST Traceable

More information

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial DMP 5 Industrial Pressure Transmitter Welded, Dry Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Industrial Pressure Transmitter Nominal pressure from 0... 6 bar up to 0... 600 bar Output

More information

N BTU/Hr Watt. N /8000 BTU/Hr. 1758/2344 Watt. N BTU/Hr Watt. Air Conditioners

N BTU/Hr Watt. N /8000 BTU/Hr. 1758/2344 Watt. N BTU/Hr Watt. Air Conditioners Spec-00732 F Sealed Enclosure Air Conditioners Sealed Enclosure Air Conditioners SPECTRACOOL Narrow Indoor/Outdoor N43 11000 BTU/Hr. 3223 Watt INDUSTRY STANDARDS N36 / BTU/Hr. / Watt N28 BTU/Hr. Watt UL/cUL

More information

70 Series End Mount 8700 Style NEMA Frame Sizes 182TC through 256TC/UC Torque Ratings: 10 to 105 lb-ft

70 Series End Mount 8700 Style NEMA Frame Sizes 182TC through 256TC/UC Torque Ratings: 10 to 105 lb-ft 70 Series End Mount 8700 Style EMA Frame Sizes 182 through 256/U Ratings: 10 to 105 Dripproof EMA 2, SA 2, IP43 70 Series Specifications: Reaction ime: 20-25 milliseconds (release and set) AK: 8.5 Register

More information

NexGen SERIES 22 QUBE Encoder

NexGen SERIES 22 QUBE Encoder ynapar brand ncoder Installation Manual NexGen SRIS 22 QU ncoder Key eatures New phased-array SI sensor ouble the loading of previous Qube xpanded resolution up to 3600PPR New IP67 sealing option Unbreakable

More information

Okta 1000, Roots pump without motor

Okta 1000, Roots pump without motor Okta 1000, Roots pump without motor Okta 1000, Roots pump without motor Similar Image High-performance Roots pump with a pumping speed of 590 to 1,775 m 3 /h Without motor (coupling and motor lantern are

More information

SOGEVAC. Rotary Vane Vacuum Pumps single-stage, oil-sealed, m 3 x h -1 ( cfm) Central Vacuum Supply Systems

SOGEVAC. Rotary Vane Vacuum Pumps single-stage, oil-sealed, m 3 x h -1 ( cfm) Central Vacuum Supply Systems SOGEVAC Rotary Vane Vacuum Pumps single-stage, oil-sealed, 10-1200 m 3 x h -1 (5.9-707 cfm) Central Vacuum Supply Systems 172.02.02 Excerpt from the Product Section C02 Edition 2010 Contents General Product

More information

Level Measurement Continuous level measurement - Capacitance transmitters

Level Measurement Continuous level measurement - Capacitance transmitters Overview Probe Applications Rod version Rod version with stilling well Cable version PFA coated cable version Extended cable with rod version Conductive liquids, slurries or solids Conductive liquids or

More information

Digital Flow Switch for Water 3 -color/2-screen display

Digital Flow Switch for Water 3 -color/2-screen display 3-color display New Digital Flow Switch for Water 3 -color/-screen display RoHS Main screen Sub screen Note 3) Main screen Sub screen Note 3) Instantaneous flow rate Set value Note ) ccumulated value Peak/ottom

More information

820 NOVA 820 NOVA. 1 Control knob. 2 Pressure regulator cap screw 3 Pilot gas rate adjuster 4 Thermocouple connection

820 NOVA 820 NOVA. 1 Control knob. 2 Pressure regulator cap screw 3 Pilot gas rate adjuster 4 Thermocouple connection MAIN FEATURES Control knob with Off, Pilot and On positions. Thermoelectric flame supervision device with re-start interlock. Near silent shut-off valve. Servo-controlled pressure regulator. Step opening

More information

SPECIFICATION FIBER OPTIC SPLICE CLOSURE. Spec No : VSS-1007-BS403A-04A/SD. VSS-0107-BS403A-04A/SD R & D Center Manufacturing Division

SPECIFICATION FIBER OPTIC SPLICE CLOSURE. Spec No : VSS-1007-BS403A-04A/SD. VSS-0107-BS403A-04A/SD R & D Center Manufacturing Division SPECIFICATION FIBER OPTIC SPLICE CLOSURE Model Spec. No. Distribution Depts. VSOF-BS403A VSS-0107-BS403A-04A/SD R & D Center Manufacturing Division Sales Division Management Division Revision 10. 07 (Rev.4)

More information

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection with Flush Process Connection piezoresistive pressure sensor up to independent contacts, configurable optional: analogue output Exprotection (for wire) cooling element up to 00 C nominal pressure ranges

More information

Revision 2.0 Parts List Minor

Revision 2.0 Parts List Minor Revision.0 www.grindex.com Parts List 803.8 Minor Table of Contents Table of Contents Introduction... Specially approved products... Product Description...3 Products included... 3 The data plate...3 Exploded

More information

WCHE BTU/Hr Watts

WCHE BTU/Hr Watts 763.576.3200 SPEC-01037 A763.422.2211 COOLING SEALED ENCLOSURE COOLING HEAT EXCHANGERS Sealed Enclosure Cooling Heat Exchangers CLIMAGUARD AIR-TO-WATER INDOOR HEAT EXCHANGERS WCHE01 2968 BTU/Hr. 870 Watts

More information

Digital Flow Switch for Water

Digital Flow Switch for Water 3-color display New Digital Flow Switch for Water RoHS IP65 3-color / 2-screen display Main screen Sub screen Note 3) Main screen Sub screen Note 3) Instantaneous flow rate Set value Note ) ccumulated

More information

High efficiency pumps with LCD display electronically controlled HEP Optimo L series, H2 product group

High efficiency pumps with LCD display electronically controlled HEP Optimo L series, H2 product group High efficiency pumps with LCD display electronically controlled HEP Optimo L series, H2 product group indicate which mode has been active or selected. By pressing the activation pushbutton for more than

More information

Proportional output thumbwheels - sprung to centre

Proportional output thumbwheels - sprung to centre New! HR series Distinctive features and specifications High reliability, long life HR-A-R Sealed to IP68 Backlighting option EMI/RFI shielding Other detent options on request Patented solution ENVIRONMENTAL

More information

CR BTU/Hr. 469 Watt. CR and 4000 BTU/Hr. 791 and 1172 Watts CR & 8000 BTU/Hr and 2344 Watts.

CR BTU/Hr. 469 Watt. CR and 4000 BTU/Hr. 791 and 1172 Watts CR & 8000 BTU/Hr and 2344 Watts. 763.576.3200 Spec-00614 I763.422.2211 Sealed Enclosure Cooling Air Conditioners Sealed Enclosure Cooling Air Conditioners PROAIR Harsh Environment CR23 1600 BTU/Hr. 469 Watt CR29 2700 and 4000 BTU/Hr.

More information

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO. DMP 5 Industrial Pressure Transmitter Welded, Dry Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 6 bar up to 0... 600 bar Output signals -wire: 4... 0 ma -wire:

More information

Revision 1.0 Parts List Minor

Revision 1.0 Parts List Minor Revision.0 www.grindex.com Parts List 803.8 Minor Table of Contents Table of Contents Introduction... Specially approved products... Product Description...3 The data plate...3 Parts... 4 Exploded view...

More information

Model # of Colors Colors Input Connection 1 K90TLGRPQ 2 Green, Red K90TLGYRPQ 3 Green, Red, Yellow K90TLBGYRPQ 4 Blue, Green, Yellow, Red

Model # of Colors Colors Input Connection 1 K90TLGRPQ 2 Green, Red K90TLGYRPQ 3 Green, Red, Yellow K90TLBGYRPQ 4 Blue, Green, Yellow, Red Datasheet Large Multicolor that Alternates Between Active Inputs Bright, uniform indicator light Alternates between colors when multiple inputs are active Models are available with up to five colors in

More information

FLOMAT. Flowmeters. Electromagnetic Insertion Flowmeter: Series. Instrumentation for fluids

FLOMAT. Flowmeters. Electromagnetic Insertion Flowmeter: Series. Instrumentation for fluids Flowmeters Instrumentation for fluids Series FLOMT FLOMT Electromagnetic Insertion Flowmeter: Introduction For use in large diameter pipes or open channels as an economical solution for liquid metering.

More information

CAPACITIVE SENSORS KAS. Series 26. Level Control Food Industry Pharmaceutical Industry Semiconductor Industry Chemical Industry

CAPACITIVE SENSORS KAS. Series 26. Level Control Food Industry Pharmaceutical Industry Semiconductor Industry Chemical Industry CAPACITIVE SENSORS KAS Series 26 Level Control Food Industry Pharmaceutical Industry Semiconductor Industry Chemical Industry Registrier-Nr.: 1327-01 Testing laboratory accredited according to DIN EN 45001

More information

Selection matrix for electronic pressure switches

Selection matrix for electronic pressure switches Selection matrix for electronic pressure switches Type / series 0500 050 050 05 050 0570 050 05 05 05 050 05 05 05 055 056 Page 09 09 7 0 5 5 5 5 9 9 9 9 9 9 Technology Measuring cell ceramic / thick-film

More information

2291 Guided Wave Radar Level Transmitter

2291 Guided Wave Radar Level Transmitter 2291 Guided Wave Radar Level Transmitter Product description / Function The 2291 Guided Wave Radar level transmitter is designed for continuous level measuring of conductive or non-conductive liquids,

More information

STE Technic Project Engineering Services Trade Ltd. Co. General Information. Main Features. Proven Performance

STE Technic Project Engineering Services Trade Ltd. Co. General Information. Main Features. Proven Performance Technic Cross-Flow Fans T R A N S F O R M E R C O O L I N G S O L U T I O N S Transformer Cross-Flow Fans General Information provides optimal solutions for air forced cooling of transformers. High performance

More information

Illustrated Feature. Options

Illustrated Feature. Options Applications Enclosed and gasketed fixtures for use where vapors, moisture, dirt or corrosive atmospheres are encountered. For use in hazardous locations defined by the NEC as Class I, Division 2. Groups

More information

Level instruments. Point level measurement - Capacitance switches. Pointek CLS100. 5/10 Siemens FI Overview.

Level instruments. Point level measurement - Capacitance switches. Pointek CLS100. 5/10 Siemens FI Overview. Siemens G 2009 Overview Configuration is a compact 2-wire inverse frequency shift capacitance switch for level detection in constricted spaces, interfaces, solids, liquids, slurries and foam. Benefits

More information

Level Measurement Point level measurement RF Capacitance switches

Level Measurement Point level measurement RF Capacitance switches Siemens AG 2018 Overview Configuration Installation Standpipes 50 (2) 20 (0.79) max. is a compact, 2-wire, inverse frequency shift capacitance switch for level and material detection in constricted spaces,

More information

Linear flow controls VFC Linear flow controls with actuator IFC

Linear flow controls VFC Linear flow controls with actuator IFC Linear flow controls VFC Linear flow controls with actuator Product brochure GB 3 Edition 01.16 Linear relationship between adjustment angle and flow rate Large control ratio of 25:1 Actuators IC 20 or

More information

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing Description The electronic pressure switch is the successful combination of hygienic process connections with flush welded

More information

PERFORMANCE SPECIFICATION SHEET CIRCUIT BREAKERS, MAGNETIC, LOW-POWER, SEALED, TRIP-FREE THREE-POLE, AUXILIARY CONTACTS

PERFORMANCE SPECIFICATION SHEET CIRCUIT BREAKERS, MAGNETIC, LOW-POWER, SEALED, TRIP-FREE THREE-POLE, AUXILIARY CONTACTS INH-POUND MIL-PRF-39019/6H 14 May 0 SUPERSEDING MIL-PRF-39019/6G 27 ugust 1997 PERFORMNE SPEIFITION SHEET IRUIT REKERS, MGNETI, LOW-POWER, SELED, TRIP-FREE THREE-POLE, UXILIRY ONTTS This specification

More information

WCHE BTU/Hr Watts

WCHE BTU/Hr Watts Spec-00754 B Sealed Enclosure Heat Exchangers Sealed Enclosure Heat Exchangers CLIMAGUARD Air-to-Water Indoor WCHE01 2968 BTU/Hr. 870 Watts WCHE04/WCHE06 7506/10577 BTU/Hr. 2200/3100 Watts WCHE14 22861

More information

Revision 2.0 Parts List Minette 1~, 3~

Revision 2.0 Parts List Minette 1~, 3~ Revision.0 www.grindex.com Parts List 80.7 Minette ~, 3~ Table of Contents Table of Contents Introduction... Specially approved products... Product Description...3 Products included... 3 The data plate...3

More information

N43 N36 N28. Sealed Enclosure Cooling Air Conditioners

N43 N36 N28. Sealed Enclosure Cooling Air Conditioners SPECTRACOOL NARROW INDOOR/OUTDOOR N43 N36 N28 11000 BTU/Hr. / BTU/Hr. BTU/Hr. 3223 Watt / Watt Watt INDUSTRY STANDARDS UL/cUL Listed; Type 12, 3R, 4; 4X optional; File No. SA6453 CE IP 56 Internal Loop

More information

Sentronic PLUS Electronic Pressure Regulator. Installation Manual

Sentronic PLUS Electronic Pressure Regulator. Installation Manual Sentronic PLUS Electronic Pressure Regulator Installation Manual Sentronic PLUS ASCO NUMATICS Sentronic PLUS Electronic Pressure Regulator Electrical Characteristics * Max. ripple: 10 % Specifications

More information

Sentronic PLUS. Electronic Pressure Regulator. Installation Manual

Sentronic PLUS. Electronic Pressure Regulator. Installation Manual Sentronic PLUS Electronic Pressure Regulator Electronic Pressure Regulator Sentronic PLUS Sentronic PLUS Electronic Pressure Regulator General Electrical Characteristics Nominal Diameter DN (mm) Voltage

More information

COILS COUPLING TABLE COILS/ELECTROPILOTS ELECTROPILOTS/SOLENOID VALVES. Electropilots. Coils. Solenoid valves G6 GL6.

COILS COUPLING TABLE COILS/ELECTROPILOTS ELECTROPILOTS/SOLENOID VALVES. Electropilots. Coils. Solenoid valves G6 GL6. COUPLING TABLE COILS/ELECTOPILOTS ELECTOPILOTS/SOLENOID VALVES Electropilots A B AA(U1) AA(U3) AB (U2) Coils U04 U05 U1 U2 U3 10 mm 15 mm 22 mm 30 mm 30 mm BE AE BD ACN CL CM ISO 1 ISO 2 ISO 3 ISO 4 ISO

More information

Bimetal Temperature Switch

Bimetal Temperature Switch Phone: +44 19 635533 Fax: +44 19 635262 Data sheet 608301 Page 1/8 Bimetal Temperature Switch Special features Electromechanical temperature switch with a fixed switching temperature Protection type IP52,

More information

EXPlora. Introduction

EXPlora. Introduction Introduction EXPlora The EXPlora range is most suited to manufacturers of ancillary electrical equipment such as motors, pumps, lighting equipment, process and control gear for use in factories and plant

More information

LMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor

LMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor LMP Screw-In Transmitter with piezoresistive Stainless Steel Sensor flush diaphragm hydrostatic level measurement of clean, thin fluid media nominal pressure ranges from 0... 40 mbar up to 0... 40 bar

More information

Revision 3.0 Parts List Salvador 1~, 3~

Revision 3.0 Parts List Salvador 1~, 3~ Revision 3.0 www.grindex.com Parts List 809.8 Salvador ~, 3~ Table of Contents Table of Contents Introduction... Specially approved products... Product Description...3 Products included... 3 The data

More information

Appendix B. Ballast Cut-sheets

Appendix B. Ballast Cut-sheets Appendix B ut-sheets Electrical Specifications VEZ-S3-S Brand Name MARK X POWERLINE Type Electronic Dimming Starting Method Programmed Start onnection Series Voltage 77 requency 50/60 HZ Status Active

More information

Panel-Mounted Thermostat

Panel-Mounted Thermostat Data Sheet 602026 Page 1/7 Panel-Mounted Thermostat EM Series Special features Safety temperature monitor STW (STB) Safety temperature limiter STB Tested according to DIN EN 14597 and PED 2014/68/EU Brief

More information

Electromagnetic Block Valves Direct Acting

Electromagnetic Block Valves Direct Acting Electromagnetic Block Valves Direct Acting Outline Drawing Models A B C D E NW16 2.50 2.28 4.43 1.58 1.58 (64) (58) (113) (40) (40) NW25 2.98 2.28 4.83 1.98 1.98 (76) (58) (123) (50) (50) Features Benefits

More information

Hazard King -HKXP Series Division 1

Hazard King -HKXP Series Division 1 Hazard King -HKXP Series Division 1 Window/ Through-Wall Explosion Proof Div. 1 / Zone 1 Air onditioning Units N.E.. and I.E.. Approved for Explosion Proof Locations 50 and 60 Hertz Models Standard Features

More information

Revision 1.0 Parts List Salvador 1~, 3~

Revision 1.0 Parts List Salvador 1~, 3~ Revision.0 www.grindex.com Parts List 809.8 Salvador ~, 3~ Table of Contents Table of Contents Introduction... Specially approved products... Product Description...3 The data plate...3 Parts... 4 Exploded

More information

Pressure Measurement Transmitters for applications with advanced requirements (Advanced)

Pressure Measurement Transmitters for applications with advanced requirements (Advanced) Siemens AG 07 Y Article No. Pressure transmitters for absolute pressure from differential pressure series, SITRANS P DS III with HART 7 M 4-7 7 7 7 7-7 7 7 7 Click on the Article No. for the online configuration

More information

www.mete-enerji.com.tr INDUSTIAL IEC PLUGS AND SOCKETS INDUSTIAL IEC PLUGS AND SOCKETS Position of the Earthing Contact acc. to IEC 60309-2 225/400-265/460 V~ 60 Hz (1) 3 P+N+ 3 P+ 2 P+ 120/208-144/250V~

More information

EZ-STATUS WLS28-2 Multicolor LED Strip Light

EZ-STATUS WLS28-2 Multicolor LED Strip Light EZ-STATUS WLS8- Multicolor LED Strip Light Datasheet Banner's WLS8- Multicolor LED Strip Lights have sturdy aluminum housings, shatterproof windows, and environmental ratings that make it ideal for harsh

More information

Data sheet: Wilo-Drain TP 50 E 101/5,5 (1~230 V)

Data sheet: Wilo-Drain TP 50 E 101/5,5 (1~230 V) Data sheet: Wilo-Drain TP 50 E 101/5,5 (1~230 V) Pump curves Wilo-Drain TP 50 E - 50 Hz - 2900 rpm Unit Max. delivery head H max 9.5 m Max. volume flow Q max 26 m 3 /h Optimal delivery head H opt 5.0 m

More information

Magnecraft Power Relays

Magnecraft Power Relays Description DPST-NO, 30 A; DPDT, 30 A (NO) / 3 A (NC) Description The series power relays offer a small package size and features Class F insulation for a maximum coil temperature of 55 C (3 F). These

More information

TFRN Industrial RTD temperature sensor. CombiTemp TM

TFRN Industrial RTD temperature sensor. CombiTemp TM Main features Pt100 sensor element, 2- or 4-wire HART uilt in graphical display, CombiView TM DFON optional Head mounted t ransmitter, FlexTop type 22xx ATEX Programmable by touch screen Easy and full

More information

Micro-Machined Silicon Transducers

Micro-Machined Silicon Transducers Micro-Machined Silicon Transducers wet/wet differential Pressure Models mv/v, 0 to 5 or 0 to 10 Vdc, or 4 to 20 ma Outputs Uni-Directional Ranges 0-25 mbar to 0-70 bar PXM409 Differential Series Standard

More information

Pressure transmitter COMPACT IO-Link,

Pressure transmitter COMPACT IO-Link, Pressure transmitter COMPACT IO-Link, for diaphragm seal operation, Type series CA1510 Features Digital pressure transmitter with IO-Link V1.1 output signal Data transmission rate COM 3 (230.4 kbaud) Hygienic

More information

Max. temp. of sensor C. Capillary tube mm. Switching difference K. Sensor cartridge mm

Max. temp. of sensor C. Capillary tube mm. Switching difference K. Sensor cartridge mm 21.610/1 RAK: Universal thermostat How energy efficiency is improved Demand-led controlling, monitoring and limiting, without auxiliary energy. Areas of application For controlling and monitoring the temperature

More information

Installation Guide. PowerLogic LVCT. 1 VAC and.333 VAC Current Transducers

Installation Guide. PowerLogic LVCT. 1 VAC and.333 VAC Current Transducers Installation Guide PowerLogic LVT 1 V and.333 V urrent Transducers ontents Installation Overview... 2 Specifications... 2 Introduction... 3 escription... 3 Ratings... 3 imensions... 4 NGR HZR O LTRI SHOK,

More information

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure DMP 4 Industrial Pressure Transmitter Without Media Isolation accuracy according to IEC 60770: 0,5 % FSO Nominal pressure from 0... 0 mbar up to 0... 000 mbar Product characteristics excellent linearity

More information

TFRH Hygienic RTD temperature sensor. CombiTemp TM

TFRH Hygienic RTD temperature sensor. CombiTemp TM Main features Pt100 sensor element, 2- or 4-wire uilt in graphical display, CombiView TM DFON optional Head mounted transmitter, FlexTop type 22xx HART, PA ATEX 3-A, FDA Programmable by touch screen Easy

More information

Environmental Technology, Inc.

Environmental Technology, Inc. Models LCD 1H and LCD 3H Snow Switch Installation and Operation Manual We manage heat Environmental Technology, Inc. 1850 N Sheridan Street South Bend, Indiana 46628 (574) 233-1202 or (800) 234-4239 FAX

More information