COILS COUPLING TABLE COILS/ELECTROPILOTS ELECTROPILOTS/SOLENOID VALVES. Electropilots. Coils. Solenoid valves G6 GL6.
|
|
- Milton Short
- 6 years ago
- Views:
Transcription
1 COUPLING TABLE COILS/ELECTOPILOTS ELECTOPILOTS/SOLENOID VALVES Electropilots A B AA(U1) AA(U3) AB (U2) Coils U04 U05 U1 U2 U3 10 mm 15 mm 22 mm 30 mm 30 mm BE AE BD ACN CL CM ISO 1 ISO 2 ISO 3 ISO 4 ISO 1 ISO 2 ISO mm ISO mm NAMU interface G1/4 Solenoid valves G6 GL6 subbase G7 PS AC AF tube Ø 4 tube Ø 6 tube Ø 8 G1/4 G1/2 G1/4 G3/8 G1/2 G1 1/2 Accessories 6 AG G1/4 G1 1/2 6_3
2 U04 10 mm coils for B series electropilots UNIVE GOUP U04 coil with integrated 90 upward connector 1,2 1,2 DE352 1,35 1,35 DE452 Upon request 12 VDC U04 coil with inline connector D500 D D ,2 1,2 DE552 1,35 1,35 DE652 D500 D D Upon request 12 VDC U04 coil with loose cables (length 300 mm) (b) 1,2 1,2 24 VDC DE052L030 Upon request 12 VDC U04 coil with inline connector with protecting cover for complete tightness 1,35 1,35 DE642I 1,35 1,35 DE652I D500 D D = 110V 230V solenoid valves must be builtin (EN602041) under continuous service a maximum temperature will not compromise the functioning of the coil provided that the working position is ventilated (b) = different wire lengths are available upon request 6_4
3 U05 15 mm coils for A series electropilots UNIVE GOUP U05 coil with integrated 90 upward connector 2 2 DD351 D500 D D U05 coil with integrated 90 upward connector 2 2 DD151 D500 D D U05 coil with inline connector 2 2 DD551 Upon request: version with LED and V DC version U05 coil with loose cables D500 D D ,5 1,5 (b) DD051L030 Accessories 2 2 DD052L030 = 110V 230V solenoid valves must be builtin (EN602041) under continuous service a maximum temperature will not compromise the functioning of the coil provided that the working position is ventilated (b) = different wire lengths are available upon request 6_5
4 U05 15 mm coils for A series electropilots / s for U04 U05 coils UNIVE GOUP U05 lato 15 mm coil Faston DC W AC VA Contin. Start Conti. Start 1,5 2 1,5 2 2,3 2,3 2,3 3,2 3,2 3,2 Tolerance tension DC AC DCV ACV Frequency HZ DD011 DD013 DD040 DD041 DD042 DD050 DD051 DD052 DD060 DD070 AM5109 s for U04 e U05 coils Length mm Coil MINIATUE CONNECTO WITHOUT WIES D500 MINIATUE CONNECTO WITH LOOSE CABLES D53030 D53050 D MINIATUE CONNECTO WITH CABLE CAUTION! Do not invert the polarity when connecting to be coil with LED. 15 mm connector D53530 D53550 D U05 AM5109 Protection according to IP65. PG9 cable connection. 180 rotation on the coil. Upon request version with LED: = 110V 230V solenoid valves must be builtin (EN602041) under continuons service a maximum temperature will not compromise the functioning of the coil provided that the working position is ventilated 6_6
5 U1 U2 U3 Coil UNIVE GOUP Possibility of replacement without intervention in the pneumatic circuit Other voltages available upon request 360 rotation on the pilot. Coil winding: H class Ambient temperature: C. Fluid temperature: C. The solenoid valves functioning with V230V must be incorporated (EN602041) Under continuous service a maximum temperature will not compromise the functioning of the coil provided that the working position is ventilated. U1 22 mm coil to be used with U1 electropilot Tolerance tension DA0050 DA0051 5,4 VA (max) 5,4 VA (max) 5,4 VA (max) 7,8 VA (max) 7,8 VA (max) 7,8 VA (max) 24 V AC/5060 HZ 110 V AC/5060 HZ 230 V AC/5060 HZ DA0106 DA0108 DA0124 U2 30 mm coil to be used with U2 electropilot continuous start DB0501 DB VA (max) 10 VA (max) 10 VA (max) 16 VA (max) 16 VA (max) 16 VA (max) 24 V AC/5060 HZ 110 V AC/5060 HZ 230 V AC/5060 HZ DB0507 DB0509 DB0510 U3 30 mm coil to be used with U1 electropilot 6 continuous start DC0301 DC0302 Accessories 3,3 VA (max) 3,3 VA (max) 3,3 VA (max) 5 VA (max) 5 VA (max) 5 VA (max) 24 V AC/5060 HZ 110 V AC/5060 HZ 230 V AC/5060 HZ DC0307 DC0309 DC0309 = 110V 230V solenoid valves must be builtin (EN602041) under continuons service a maximum temperature will not compromise the functioning of the coil provided that the working position is ventilated 6_7
6 s UNIVE GOUP for U1 coil Coil U1 AM5110 Protection according to IP 65. PG9 cable connection. 180 rotation on the coil LED and moulded cable are available upon request. for U2, U3 coil Coil DIN connector U2/U3 AM5111 Protection according to IP 65. PG9 cable connection. 360 rotation on the coil. LED and moulded cable are available upon request. 6_8
7 Coils U04 U05 U1 U2 U3 Coils and s Electropilots 3 MATCHING TABLE COILS/ELECTOPILOTS ELECTOPILOTS/SOLENOID VALVES A (U05) B (U04) AA (U1) AA (U3) AB (U2) U04 10 mm Solenoid valves Coils U05 U1 U2 U3 BE AE BD ACN CL CM COMPA 2/4 G6 GL6 G7 PS 15 mm 22 mm 30 mm 30 mm ISO 1 ISO 2 ISO 3 ISO 4 ISO 1 ISO 2 ISO mm ISO mm Interface NAMU G1/4 subbase tube Ø 4 tube Ø 6 tube Ø 8 AC G1/4 G1/2 AF G1/4 G3/8 G1/2 G1 G1 1/2 AG G1/4 G1 G1 1/2 P15E = Standard = Upon request = M12 10 mm U04 Coils for B series electropilots With integrated 90 upward connector With inline connector DE352 1,2 W DE452 1,35 W (with led) DE355 0,5 W NEW : D500 D D DE552 1,2 W DE652 1,35 W (with led) DE555 0,5 W NEW : D500 D D With loose cables (length 300 mm) With inline connector with protecting cover for complete tightness DE052L030 1,2 W DE642I 1,35 W DE652I 1,35 W (with led) DE655I 0,5 W NEW : D530C D530C Subject to change
8 U04 U05 U1 U2 U3 Coils and s UNIVE GOUP 15 mm U05 Coils for A series electropilot with integrated 90 upward connector with integrated 90 downward connector with inline connector DD351 2 W DD151 2 W : D500 D D : D500 D D DD551 2 W : D500 D D VALVES with loose cables 15 mm Faston DD051L030 DD052L030 2 W W DD013 DD040 DD041 DD042 DD050 : AM V AC Hz VA 24 V AC Hz 2,3 VA 2 W W 48 V AC Hz 2,3 VA DD051 DD052 DD060 DD070 2 W W 110 V AC Hz 2,3 VA 230 V AC Hz 2,3 VA U1 U2 U3 Coil 22 mm (U1) 30 mm (U2) DA0050 DA0051 DA0106 DA0108 DA0124 W W 24 V AC Hz 5 VA 110 V AC Hz 5 VA 230 V AC Hz 5 VA DB0501 DB0502 DB0507 DB0509 DB W 11 W 24 V AC Hz 10 VA 110 V AC Hz 10 VA 230 V AC Hz 10 VA 30 mm (U3) DC0301 DC0302 DC0307 DC0309 DC0310 W W 24 V AC Hz 3,3 VA 110 V AC Hz 3,3 VA 230 V AC Hz 3,3 VA U1U2U3 coils are certified in compliance with CSA regulation, certificate n. L For coils certified in compliance with UL regulation, please contact our Sales Office s Miniature connector without wires D500 Miniature connector with loose cables D53030 D53050 D Miniature connector with cable D53530 D53550 D mm 20 mm 30 mm AM5109 U05 AM5110 U1 AM5111 U2/U3 Subject to change 3 87
3/2-directional valve, electrically operated, Series AS3-SOV G 3/8 - G 1/2 pipe connection ATEX optional
Preparation of compressed air Maintenance units and components 1 IM0046156 Version Poppet valve, Can be assembled into blocks Nominal flow 4500 l/min Nominal flow, 1 2 4500 l/min Nominal flow, 2 3 3200
More informationSERIES x5. Nickel-plated brass Connection 1) PUR cable type 1 Degree of protection. IP 67 Mounting. Embeddable Max. switching frequency
1 Size SERIES 400 x SERIES x Operating distance mm 0.8 0.8 1. Housing material Connection 1) PUR cable type 1 PUR cable type 1 / Connector S8 PUR cable type 1 Degree of protection Mounting Max. switching
More informationSERIES 400 SERIES 620
x 0. 0... PUR cable type,000 Hz SERIES 00 SERIES 0 0,000 Hz Table Diagram ---.... 9 VDC /. ma** PUR cable type / Connector S,000 Hz 0,000 Hz Table Diagram ---.... 9 VDC /. ma** PUR cable type,000 Hz x
More informationSize B INDUSTRIAL STANDARD
Size B INDUSTRIA STANDARD Actuators series DIN EN 70-80 Industrial standard + ow housing Degree of protection IP6 Wired versions Moulded versions Degree of protection IP67 Female power connector Cable
More informationCoils for solenoid valves
MAKING MODERN LIVING POSSIBLE Technical leaflet Coils for solenoid valves www.danfoss.com B and A coils Encapsulated coils with long operating life, even under extreme conditions Standard coils for a.c.
More informationNessie Coils for VDH and VDHT valves
Data Sheet Nessie Coils for VDH and VDHT valves Introduction The coils for the Danfoss High-Pressure Systems valves are high-performance and reliable coils based on more than 50 years manufacturing of
More informationSingle Point Flow Monitor SW118 SW119
SW8 SW9 SW8 SW9 Single point flow monitors with MIN/MAX monitoring function, suitable for water, oil, air and media with similar thermal conductivities (selectable by means of a medium switch). With either
More informationLC3D115M7 TeSys D - star delta starter - 3 x 3P (3 NO) A V AC coil
Characteristics TeSys D - star delta starter - 3 x 3P (3 NO) - 115 A - 220 V AC coil Main Range Product name Product or component type Device short name Contactor application Utilisation category Device
More informationRCA3 SOLENOID PILOT VALVES PENTAIR CLEAN AIR SYSTEMS
RCA3 SOLENOID S PENTAIR CLEAN AIR SYSTEMS GOYEN RCA3D REMOTE PILOT Remote solenoid pilot valve to control the actuation of dust collector diaphragm valves. RCA3D with flying lead connection INSTALLATION
More informationMechanical flow switch for On/Off control
Mechanical flow switch for On/Off control Economic integration in pipe systems without any additional piping Magnetic measuring principle Mechanical adjustment of setpoint Type 8010 can be combined with...
More informationSITOP power supply. Technical data, April SITOP Power Supply. Answers for industry.
SITOP power supply Technical data, April 2010 SITOP Power Supply Answers for industry. SITOP reliable power supply Efficient operation of a machine or plant requires a reliable, constant power supply.
More informationPhotoelectrics Through-beam Type PA18C.T..., DC
Photoelectrics Through-beam Type, DC Miniature sensor range Range: 20 m (Axial), 16 m (Radial) Sensitivity adjustment by potentiometer Modulated, infrared light 850 nm Supply voltage: to 30 VDC Output:
More informationLinear flow control with actuator IFC
Linear flow control with actuator Product brochure GB 3 Edition 01.14 Linear relationship between adjustment angle and flow rate Large control ratio of 25:1 EC type-tested and certified Actuators IC 20
More information1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control
IEC Contactors and Starters. XT Family of Contactors Contactors and Starters Product Description The Eaton XT contactors and starters includes nonreversing and reversing contactors, overload relays and
More informationLC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil
Product data sheet Characteristics LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationLinear flow controls VFC Linear flow controls with actuator IFC
Linear flow controls VFC Linear flow controls with actuator Product brochure GB 3 Edition 01.16 Linear relationship between adjustment angle and flow rate Large control ratio of 25:1 Actuators IC 20 or
More informationHigh performance circuit breakers
Series High performance Description The high performance MCB offers a compact solution to circuit protection. The devices are DIN rail mounted. The is available with application-specific trip characteristics
More informationPhotoelectric Sensors E3F2
Photoelectric Sensors E3F2 Threaded Cylindrical Photoelectric Sensors with Built-in Amplifier for Use as an Optical Proximity Switch M18 DIN-sized cylindrical housing Housing materials: plastic, nickel
More informationLC3D180AV7 TeSys D - star delta starter - 3 x 3P (3 NO) - 18 A V AC coil
Characteristics TeSys D - star delta starter - 3 x 3P (3 NO) - 18 A - 400 V AC coil Main Range Product name Product or component type Device short name Contactor application Utilisation category Device
More informationLC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil
Product datasheet Characteristics LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationKuhnke Technical Data. Contact Details
Kuhnke Technical Data The following page(s) are extracted from multi-page Kuhnke product catalogues or CDROMs and any page number shown is relevant to the original document. The PDF sheets here may have
More informationPart-Turn Electric Multi-Turn Electric
Optional 7 Handwheel Available NEMA 4 Enclosure Approvals MAR s Only (Canadian Standard Association) Enclosure NEMA 7 Enclosure Approvals MAR s Only (Canadian Standard Association) Class I, Divisions 1
More informationSolenoid Valves. Inline Valves IV. Nominal diameter 3 mm. Suitability for Industry-Specific Applications Schmalz - Applications.
Solenoid s Inline s IV Nominal diameter 3 mm Suitability for Industry-Specific Applications Applications Inline valve for deactivation of unused suction pads Individual control of the suction pads of a
More informationSiemens AG Safety along the complete line: SIRIUS 3SE7 cable-operated switches SIRIUS. Answers for industry.
Safety along the complete line: 3SE7 cable-operated switches Answers for industry. Everything well under control. 3SE7 cable-operated switches With cable-operated switches from our 3SE7 product range,
More informationRead/write head TN-CK40-H1147
Rectangular, height 40 mm Read/write head (5 positions) Plastic, PBT-GF30-VO Every read/write head can communicate with a number of different TURCK data carriers. Powered and operated only via BL ident
More informationProduct Data Sheet
Product Data Sheet www.moteck.com Actuator ID11 ID11 is designed for industrial applications, such as agricultural and construction machines. Comparing with ID1, the installation length of ID11 is 4mm
More informationAPPLICATIONS. Automatic warehouse. Trasportation lines
INDUCTIVE TUBULAR SENSOR M12 SERIES There are millions of inductive sensors deployed in almost every area of factory automation. They detect metal objects contactless and are distinguished by a long operating
More informationCentrifuge 5418/5418 R
Register your instrument! www.eppendorf.com/myeppendorf Operating Manual Technical data 41 9 Technical data 9.1 Power supply Centrifuge 5418 Mains connection Centrifuge 5418 R 230 V, 50 Hz 60 Hz 120 V,
More informationLED DRIVERS. LQC4D-V1 4 channels. User Manual FEATURES
pag. 1/13 FEATURES Outputs: 4 x channels BUS+SEQUENCER+FADER+DIMMER+DRIVER Input: DC 12/24/48 Vdc BUS Command: DALI LOCAL Command: 4x N.O. push button (with or without memory), 0-10V, 1-10V Controls: dimmer,
More informationSentronic PLUS Electronic Pressure Regulator. Installation Manual
Sentronic PLUS Electronic Pressure Regulator Installation Manual Sentronic PLUS ASCO NUMATICS Sentronic PLUS Electronic Pressure Regulator Electrical Characteristics * Max. ripple: 10 % Specifications
More information82540/ /2-way diaphragm valves
> > ort size: DN 8... 50, 1/4... 2 (ISO G/NT) > > Valve operates without differential pressure > > High flow rate > > For robust industry solutions > > Damped operation > > Suitable for vacuum > > Solenoid
More information3.5. Control Relays and Timers. Contents. 9575H Series 3000 Type AA, AC and DC. General Purpose Relays Type AA
.5 9575H Series 000 Relay Contents 9575H Series 000 Type AA, AC and DC Product Selection....................... Accessories............................ Technical Data and Specifications........... Dimensions............................
More informationElectronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650
M. K. JUCHHEIM GmbH & Co Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.de
More information1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control
XT Family of Contactors Contactors and Starters Product Description The Eaton XT contactors and starters includes nonreversing and reversing contactors, overload relays and a variety of related accessories.
More information-V- New. Connecting cables for valves, socket type B, industry standard Type codes Connecting cable with PUR cable sheath NEBV B2 W 3 F P K 0.
Type codes Connecting cable with PUR cable sheath NEBV B2 W 3 F P K 0.6 N LE 3 NEBV Connecting cables for valves Connection technology on left, field device side B2 Socket type B to industry standard,
More informationtechnical data (according to IEC ) Degree of protection IP 67 Max. ripple content 15 % U B / 20 % U B (amplifier) No-load supply current
Inductive Sensors: high-temperature ü For ambient temperatures of up to +230 C ü With integrated electronics, up to +180 C ü With external electronics, up to +230 C ü Excellent long-term reliability (according
More informationMagnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A
and 3DPT, 10 A UL Listed when used with proper Magnecraft s The 750R series octal base, plug-in relays offer clear or full-feature covers with multiple mounting options and accessories. 750R 750R Full-Feature
More informationBUS UNITRONIC BUS CAN
BUS UNITRONIC BUS CAN For CAN bus systems; stationary applications; 120 Ω LAPP KABEL UNITRONIC BUS CAN UNITRONIC BUS CAN is designed to the CAN open and ISO11898 standard. It is well suited for high-speed
More informationPROXIMITY SWITCHES INDUCTIVE TUBULAR SENSOR M30 SERIES HIGHLIGHTS APPLICATIONS
INDUCTIVE TUBULAR SENSOR M30 SERIES There are millions of inductive sensors deployed in almost every area of factory automation. They detect metal objects contactless and are distinguished by a long operating
More informationLevel Measurement silometer FMC 420, FMC 423
Technical Information TI 077F/00/en Level Measurement silometer FMC 420, FMC 423 For connecting to capacitance probes or Deltapilot S hydrostatic probes Main applications The is used for continuous level
More informationModular Lube Lubrication Systems System Controls
Model 84501 Program Timer Solid State Designed to control the lubrication cycle frequency of air-operated single-stroke pumps. Timer turns pump on/off at programmed intervals via a 3-way or 4-way air solenoid
More informationElectrical connection
Color sensors Dimensioned drawing en 02-2013/01 50121262 068-14515 12mm 32mm 10-30 V DC 500 Hz Scanner for color detection Simultaneous selection of up to 3 colors Detection independent of distance Teach-in
More informationDIN EUROCARD CONNECTORS
DIN 41612 EUROCARD CONNECTORS 2230 SERIES SERIES. Vertical Female Type Half B Connectors. PCB Solder 4mm Wrap post tail length 13mm Wrap post tail length 17mm Soldar cable 16 a 2230 T061 2230 T063 2230
More informationSOFTLINK 300. Modules Specifications. Reference Manual
SOFTLINK 300 Reference Manual Edition 04/2011 Preface Purpose of the manual This manual gives you a brief overview of SOFTLINK 300 Modules. You can look up information on the description, order No., technical
More informationActuators IC 20, IC 40
Actuators IC 20, IC 40 IC 20 for basic applications with three-point step control and automatic/manual mode changeover for easy commissioning IC 40 for complex applications with programmable functions
More information9 Control Equipment. Measurement- and Control Equipment Series 8214, 8218
9 Control Equipment Measurement- and Control Equipment Series, Explosion protection to CENELEC IEC Can be used in Zone 1 and Zone 2 Designed for panel mounting Enclosure material : Polyester resin : Aluminium,
More informationSafety dialogue solutions
Characteristics 5 Environment Conformity to standards Products XY2 CH, XY2 CE: EN/IEC 60947-5-1, EN/ISO 13850:2006, UL 508 and CSA C 22-2 n 14 (with suffi x H7) XY2 CB: EN/IEC 60947-5-1, EN/ISO 13850:2006,
More informationSentronic PLUS. Electronic Pressure Regulator. Installation Manual
Sentronic PLUS Electronic Pressure Regulator Electronic Pressure Regulator Sentronic PLUS Sentronic PLUS Electronic Pressure Regulator General Electrical Characteristics Nominal Diameter DN (mm) Voltage
More informationLC1D50AFE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil
Product data sheet Characteristics LC1D50AFE7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationFLUID VIEW 12V LED TAPE LIGHT
DRY LOCATION FLUID VIEW 12V LED TAPE LIGHT Medium brightness Available in 8+ CRI 16.4 ft. maximum run UL Listed & R/C SAM Manual Suitable for closet use 5-Year limited warranty SUITABLE FOR CLOSET USE
More informationFLEXIBLE SERIES DA LR WW LENTUS
Technical Information is an ideal solution which can be used easily for limited areas or thin spaces because of its minimalist design of 1cm, flexible body structure and sticky band feature found behind..
More informationV 180 Series Photoelectric Switches
D A T A S H E E T V 180 Series Photoelectric Switches VS 180 / VE 180 1 m x VL 180 m 1 m*) *) with polarizing filter v VT 180 110 mm 00 mm n Photoelectric switches of cylindrical design in threaded metal
More informationType Contact form Model
Low Signal Relay G6A High sensitivity can be driven by digital circuits. Low-profile design allows use in.70 mm (0.50 in) PC board rack. Surge withstand meets FCC Part 68 regulation. Units can be mounted
More information1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control
. XT Family of Contactors Contactors and Starters Product Description The Eaton XT contactors and starters includes nonreversing and reversing contactors, overload relays and a variety of related accessories.
More informationGOYEN PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS CLEAN AIR SOLUTIONS PRODUCT LEAFLET
PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS CLEAN AIR SOLUTIONS 3-6VFD COMBINATION FLAME AND DUST IGNITION PROOF ENCLOSURES Goyen pilot valve enclosures for hazardous locations are available in a combination
More informationConnecting cables for valves, socket type A, EN Type codes Connecting cable with PUR cable sheath
Type codes Connecting cable with PUR cable sheath NEBV A1 W 3 F P K 0.6 N LE 3 Function NEBV Connecting cables for valves Connection technology on left, field device side A1 Plug socket type A, EN 175301-803
More informationLC3D80B7 TeSys D - star delta starter - 3 x 3P (3 NO) - 80 A - 24 V AC coil
Characteristics TeSys D - star delta starter - 3 x 3P (3 NO) - 80 A - 24 V AC coil Price* : 4058.00 USD has not been replaced. Please contact your customer care center for more information. Main Range
More informationMinicontactorrelay,2NO/2NC,DCoperated
Minicontactorrelay,2NO/2NC,DCoperated Partno. DILER-22-G(24VDC) Articleno. 010042 CatalogNo. XTRM10A22TD Deliveryprogramme Product range DILER Mini-contactors Application Contactor relays Connection technique
More information1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control
. XT Family of Contactors Contactors and Starters Product Description The Eaton XT contactors and starters includes nonreversing and reversing contactors, overload relays and a variety of related accessories.
More informationRoots pumps with a pumping speed of 280 to 840 m 3 /h: Okta 500 DUO DN1 DN B A
3.1 Vacuum generation / / Convection cooled OktaLine Okta 500 with a pumping speed of 280 to 840 m 3 /h: High-performance Roots pump with a pumping speed of 280 to 840 m 3 /h With 3-phase motor, IE2 No
More information1.1. Contactors and Starters... Contents Description Relays and Timers Catalog Number Selection... Product Selection...
IEC ors and Starters. Contents Description Catalog Number Selection................ Product Selection....................... Accessories........................... Technical Data and Specifications..........
More informationSensor technologies Proximity sensors Series ST4. Brochure
Series ST Brochure 2 Series ST ST Sensor, Series ST with cable open cable ends, -pin Sensor, Series ST mm C-slot with cable Plug, M8, -pin 6 Sensor, Series ST mm C-slot with cable Plug, M8, -pin, with
More informationProcess Transmitter RMA 422
Technical Information TI 072R/24/ae Process Transmitter RMA 422 Multi-functional 1-2 channel top hat DIN rail unit with loop power supply, alarm set point monitoring, mathematics function and 1-2 analog
More informationLC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC
Product datasheet Characteristics LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC Price* : 86.25 GBP Main Range Product name Product or component type Device short name Contactor application Utilisation category
More informationTeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40
Characteristics Type of contactor LC- LC- LC- LC- LC-D & D09 D8 D2 D38 D40 D0 D9 LC-D0 DT20 & DT2 DT32 & DT40 Environment Rated insulation voltage (Ui) Conforming to IEC 947-4-, overvoltage category III,
More informationPanel-Mounted Thermostat
Data Sheet 602026 Page 1/7 Panel-Mounted Thermostat EM Series Special features Safety temperature monitor STW (STB) Safety temperature limiter STB Tested according to DIN EN 14597 and PED 2014/68/EU Brief
More informationElectrical connection
Colour sensors Dimensioned drawing Part No. 50109619 12.5mm 60mm 10-30 V DC 6 khz Scanner for colour detection Very short response time 85µs for detection of fast or small objects and marks Direct indication
More informationSTE Technic Project Engineering Services Trade Ltd. Co. General Information. Main Features. Proven Performance
Technic Cross-Flow Fans T R A N S F O R M E R C O O L I N G S O L U T I O N S Transformer Cross-Flow Fans General Information provides optimal solutions for air forced cooling of transformers. High performance
More informationDMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.
DMP 5 Industrial Pressure Transmitter Welded, Dry Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 6 bar up to 0... 600 bar Output signals -wire: 4... 0 ma -wire:
More informationLC1D150B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A - 24 V AC 50/60 Hz coil
Product data sheet Characteristics LC1D150B7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationLC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil
Product datasheet Characteristics LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationI Ex-protected connectors exlink I
Y-Junction-box Technical data Y-Junction-box / Marking to 94/9/EC II 2 G Ex de IIC T6/T5 / II 2D Ex td A21 T80 C/ T95 C EC-Type Examination Certificate PTB 05 ATEX 1084 IECEx-Certificate of Conformity
More informationAK-PVE4 Operating Instructions. Measuring of norm signals in wall-type units. Performance:
AK-PVE4 Operating Instructions Measuring of norm signals in wall-type units 1 2 P Performance: Digit heights: 20 mm Colour: red Display range: -999 9999 Wall-type housing: light grey made of ABS-plastic
More informationPROPORTIONAL VALVES Sentronic plus
04GB-06/R0 PROPORTIONAL VALVES Sentronic plus with external pressure supply G / FEATURES Sentronic plus is a highly dynamical -way proportional valve with digital control. Sentronic plus stands for: Digital
More informationAnalog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/
> 8 channels for 2-wire HART transmitters > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit monitoring for each field circuit > Module
More informationSelection table SITOP power supplies
Selection table SITOP power supplies Input voltage Output voltage 1-phase 120 V AC, 230 V AC Output current SITOP compact LOGO!Power SITOP lite SITOP smart SITOP modular SIMATIC Design Special design,
More information1. Uses. 2. Power Supply. 1) Removal or Positioning of Weld Lines. 2) Regulation of the Injection Quantity by Gate Operation
1. Uses YUDO have produced the Sequence Injection Timer - SIT500 Series to provide a means of controlling the mould filling sequence when using Valve Gate Hot- Runner Systems. The Sequence Injection Timer
More informationINSTALLATION MANUAL FT-FOTR-1VDE-ST-S
INSTALLATION MANUAL FT-FOTR-1VDE-ST-S 1-Channel Digital Duplex Baseband Video Transmitter and Receiver With Reverse Data Transmission & Ethernet Transmission v1.0 4/5/11 1 PACKAGE CONTENTS This package
More informationRead/write head TN-M18-H1147
Threaded barrel, M18 x 1 Chrome-plated brass Every read/write head can communicate with a number of different TURCK data carriers. Powered and operated solely via BLident interface module M12 x 1 male,
More informationRead/Write Head TN-CK40-H1147
Rectangular, height 40 mm Read/write head (5 positions) Plastic, PBT-GF30-VO /S2503 Connectors /S2500 Connectors Type designation Ident no. 7030006 Mounting conditions Non-flush Ambient temperature -25
More informationAC 2-wire Inductive Sensors
Tubular, M12 1 AC-sensors are optimized for controllers with alternating current inputs. When maintaining the rated operating current, the sensors can directly control fuses and relays. Housing size M12
More informationFilters for Power Lines (Low Leakage Current)
Filters for Power Lines (Low Leakage Current) 40 to 100 A, 100 db from 150 khz Series/Type: Date: January 2004 EPCOS AG 2015. Reproduction, publication and dissemination of this publication, enclosures
More informationPendant Light Fitting IEC Series 6470/2
> Available light sources high-pressure sodium lamps (HSE) metal halide lamps (HIE) halogen lamps (QT) > Versatile mounting methods > Enclosure made of saltwater-resistant aluminium www.stahl.de 11435E
More informationDatasheet - SRB301LC 24VAC/DC
25.02.2016-18:05:23h Datasheet - SRB301LC 24VAC/DC Guard door monitors and Safety control modules for Emergency Stop applications / General Purpose safety controllers (Series PROTECT SRB) / SRB301LC Preferred
More informationProduct Data Sheet 4656 ZW
The engineer's choice 4656 ZW INDEX 1 General... 3 2 Mechanics... 3 2.1 GENERAL... 3 2.2 CONNECTIONS... 4 3 Operating Data... 5 3.1 ELECTRICAL OPERATING DATA... 5 3.2 OPERATING DATA - ELECTRICAL INTERFACE
More informationALLEN BRADLEY TIMING RELAY
ALLEN BRADLEY TIMING RELAY Configuration Details Product: 700-HS12BA1 Description: 700-HS General Purpose Square Base Timing Relay, On Delay Timer, 1.0 to 180 seconds, DPDT, 120V AC 50/60Hz CONTROL RELAY
More informationLC1D65AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC 50/60 Hz coil
Characteristics TeSys D contactor - 3P(3 NO) - AC-3 -
More informationStandard signal metering in wall-mounting case
User manual AKV-2VR4C Standard signal metering in wall-mounting case Technical features: Digit height: 20 mm Colour: red Range of display: -999 9999 Wall-mounting case: black, made of ABS-plastic Protection
More informationCapacitance Limit Detection nivotester FTC 420/421/422
Technical Information TI 127F/00/en Capacitance Limit Detection nivotester FTC 420/421/422 Limit switches in Minipac design for liquids and bulk solids Application Nivotester FTC 420...422 capacitive limit
More informationCAPACITIVE SENSORS KAS. Series 26. Level Control Food Industry Pharmaceutical Industry Semiconductor Industry Chemical Industry
CAPACITIVE SENSORS KAS Series 26 Level Control Food Industry Pharmaceutical Industry Semiconductor Industry Chemical Industry Registrier-Nr.: 1327-01 Testing laboratory accredited according to DIN EN 45001
More informationAccessories EXP1 - cards to 19 rack extending the number of 1Vpp outputs to 3 at one-input cards
BREAK-TW-V.4/4, BREAK--V.4/4 BOX DIN RACK IP56 Optoconverters are designed to transfer videosignal and or data. I FM modulation I AGC optical loss I Universal for MM and SM fibres I Up to 3 independent
More informationProduct Data Sheet 4650 N-465
The engineer's choice 4650 N-465 INDEX 1 General... 3 2 Mechanics... 3 2.1 GENERAL... 3 2.2 CONNECTIONS... 4 3 Operating Data... 5 3.1 ELECTRICAL OPERATING DATA... 5 3.2 ELECTRICAL FEATURES... 5 3.3 AERODYNAMIC...
More information1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control
. XT Family of Contactors Contactors and Starters Product Description The Eaton XT contactors and starters includes nonreversing and reversing contactors, overload relays and a variety of related accessories.
More informationLVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:
HM 1808 LVDT Inductive Position Transducer - Hydraulic Series SM-HYD Hydraulic Series Key-Features: Content: - Screw flange M18x1,5 / M30x1,5 or plug-in flange Ø18 - Pressure up to 400 bar - Measurement
More informationE6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm
Low-cost Encoder with Diameter of 50 mm CSM DS_E An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. High-precision detection of automatic machine timing.
More informationProduct Data Sheet 8506 VW-691
The engineer's choice 8506 VW-691 INDEX 1 General... 3 2 Mechanics... 3 2.1 GENERAL... 3 2.2 CONNECTIONS... 4 3 Operating Data... 5 3.1 ELECTRICAL OPERATING DATA... 5 3.2 OPERATING DATA - ELECTRICAL INTERFACE
More informationProcess transmitter RMA422
Technical information TI072R/09/en Mat. No. 51001905 Process transmitter RMA422 Multifunctional 1-2 channel top hat DIN rail unit with intrinsically safe current input and loop power supply, alarm set
More informationCOVER PAGE FOR TEST REPORT
Issue Date: 2007-05-23 Page 1 of 3 Report Reference # E135803-A37-UL-1 COVER PAGE FOR TEST REPORT Product Category: Product Category CCN: Test Procedure: Product: Model/Type Reference: Rating(s): Power
More informationAnalog Input Module HART Ex n Inputs, 8 Channels Series 9461/15
> 8 channels for 2-wire HART transmitters > Inputs for Ex nl, Ex na and Nonincendive > Galvanic separation between inputs and system > Open-circuit and short-circuit monitoring for each field circuit >
More informationMedia Tube CW x 48.5mm 1.12 x mm mm mm kg 5.1lbs. 1.6kg 3.5lbs
Date: Quantity: Company: Project: Media Tube CW The Traxon Media Tube CW is an IP66/IP67-rated slim LED tube for any wall or façade media lighting. Available in 295mm, 495mm, 995mm, and 1495mm lengths,
More information