1 ÉTUDES ET RÉALISATIONS ÉLECTRONIQUES / INSTRUENTATIONS / AUTOATISE CURRENT GENERATOR programmable, ± points Route de Brindas - Parc d activité d Arbora - N Soucieu en Jarrest Tél Fax Tel. Intern Fax Intern ARDETE - TA IN/14 - B 04/03 - Any data in this documentation may be modified without prior tice. G 400 User handbook Valid for instruments with version 01.xx RCS Lyon B http: // - info@ardetem.com ARDETE Soucieu en Jarrest - FRANCE

2 Summary 1. INTRODUCTION p2 2. SPACE REQUIREENTS p2 3. CONNECTINGS p3 4. PROGRAING p3 4.1 Communication with the instrument p3 4.2 Orientation through the programming p3 4.3 ain menu p4 4.4 Programming menu p Programming of the display p4 4.5 Features of the inputs and programming limits p Logic inputs (optional) p6 4.6 Features of the outputs and programming limits p Analog output p6 Summary 6. ERROR ESSAGES p8 7. GENERAL WARRANTY TERS p8 8. LEXIQUE p Display features p6 4.7 Reading of the configuration p6 4.8 Access code p7 4.9 Programming of a new access code p Functions which can be reached from the main menu p Generating of an output value p Entering of the increase step p8 5. FUNCTIONS ACCESSIBLE FRO THE FRONT FACE p8 5.1 Decreasing of the output signal p8 5.2 Increasing of the output signal p8 p1

3 1. INTRODUCTION The G400 is a digital current genera (0-25 ma). Each instrument is equipped on its front face with a five 14mm high red digits display, whose brightness suits applications in industrial control rooms perfectly. A programmable display scale fac allows visualising the value of the generated current in display units permanently. It can be fitted as option with 2 insulated logic inputs with programmable functions. Functions: - Programmable display scale fac - easurement of the current generated on the output (in display unit) - Entering of the generated value (in display unit) - Increasing or decreasing of the output signal by pressing of a key. - Complies with standards EN on rejections and EN ; immunity (industrial environment) EN level 3, EN level 3, EN level 4, EN level 3. CE marking according to the directive EC SPACE REQUIREENTS Dimensions of the housing: (L x H x D) (with terminals) 96 x 48 x 124 mm Holding panel max. thickness 30 Option logic inputs: (specify on order) - Generating of a specific value by logic inputs - Increasing or decreasing of the output signal by logic inputs terminals case tightenings external seal General features: - Accuracy: 0.1 % of the full scale at +25 C - Thermic drift < 150 ppm/ C - Residual ripple 0,2 % - Admissible load 0Ω < Lr < 450 Ω (Lr: load resistance) - Response time: 40ms - Insulation: inputs / power supply: 2,5 kv eff. 50Hz-1min inputs / output: 2.5 kv eff. 50Hz-1min Panel mounting cut out 44 x 91 mm - Power supply: (specify on order) 2 Versions: High Voltage or Low Voltage High Voltage: Vac and Vdc 50/60/400 Hz Low Voltage: Vac and Vdc 50/60/400 Hz - Power draw: 5 W max. 8 VA max. Protection: Front face: IP 65 Housing: IP20 Terminals: IP 20 Housing: Self-extinguishing case of black UL 94 V0 ABS. Plug-off connecs on rear face for screwed connectings (2.5mm², flexible or rigid) Display: ± points (14 mm) Electroluminescent red (green optional) p2

4 3. CONNECTINGS OUTPUT CURRENT /25 ma active ma C B A C Location of the terminals (view of case rear side) D E Reading convention: ove through the main menu Revert to previous menu Blinking display: awaiting validation or setting Entering of a parameter: First start by increasing or decreasing the 1st digit and the sign: from -9 to +9. The 2nd from 0 to 9. The 3rd from 0 to 9. The 4th from 0 to 9. and Between each entering, validate the cipher with key OPTION LOGIC INPUTS channels TOR 1 TOR 2 CO E 4. PROGRAING POWER SUPPLY AC DC ~ ~ Communication with the instruments During the measuring several functions can be reached from the front face: Display of the measure A 4.2 Orientation through the programming The dialogue is ensured by 4 keys located on the front face. ove through the menus: downwards, or decrease the value shown Validation of the displayed parameter, or access to a submenu Exit from a submenu to access the next menu / access to the programming exit menu Note: In mode programming, the instrument will automatically revert to measure with the former configuration if key is pressed during 1min. ove through the menus: upwards, or increase the value shown Decreasing of the output signal p8 Increasing of the output signal p8 Access to the main menu p4 p3

5 4.3 ain menu scroll menus vertical move Programming of the display read ProG P.CodE EIS StEP displ. displ. ode reading of the configuration (see p6) CodE If code correct, access to the programming menu (see p4) Programming of the access code (see p7) Generating of an output value (see p7) Entering of the increase step (see p8) Authorized by access code Entering of the access code The access to the programming menu is protected by a 4-cipher code. The code is 0000 on facy exit (to change the code, see page 7) Point d.disp F.diSP Out.A place of the decimal point (1) display corresponding to the output down scale d.out display corresponding to the output full scale F.out (1) Changing this parameter requires re-programming the following parameters: d.disp, FdiSP, 4.4 Programming menu displ. OUt.A SAuE Access to the programming of the display fac p4 Access to the programming of the analog output p5 Access to the programming of the logic inputs (option logic inputs) p5 Access to the programming of the display brightness p5 Access to the programming exit menu with or without saving the configuration p5 Note: Press to go on to the next menu ove through the menus / choice Note: Press to go to the menu SAuE In mode programming, the instrument will automatically revert to measure with the former configuration if key is pressed during 1min. enu exit / access Downwards move / decrease Upwards move / increase Validation / vertical move p4

6 Out.A if option d.out F.out Liit or (2) (2) YES down scale of the analog output (2) < x < (ma) full scale of the analog output no Analog output Out.A YES: The analog output can t exceed the values d.out and F.out No: The analog output can range from 0 to 27.5 ma. See also the features of the outputs p6 br.dig null SAuE adjusting of the digits brightness on 4 levels deleting of the unsignificant zeros YES See also the display features p6 Programming of the brightness of the displays (3) 1 2 ualue EiS function entering of the value to be generated (value + decimal point) in display unit VAluE EiS (3) (3) InCrE. function increasing of the output signal InCrE. decre. function decreasing of the output signal If Liit = YES then EiS.1 and EiS.2 can t exceed the values d.disp and F.diSP. If Liit = No then EiS.1 and EiS.2 can t exceed the display value corresponding to an analog output < 0 or > 27.5 ma. If EiS.1 and/or EiS.2 are programmed out of range, the instrument will propose after SAvE YES a new entering of these parameters. decre. See also the features of the logic inputs p6 Option logic inputs revert to the measure display SAuE YES exit and save the configuration exit without saving the configuration Exit from the programming with or without saving SAvE Note: In case the position of the decimal point has been modified, the instrument will propose after SAvE YES all the parameters related to the decimal point which have t been modified (see page 4). If EiS.1 and/or EiS.2 are programmed out of range the instrument will propose after entering these parameters again, after SAvE YES. After SAvE YES, the analog output is enforced to the value d.out. Note: Press to go on to the next menu ove through the menus / choice enu exit/access Downwards move / decrease Upwards move / increase Validation / vertical move p5

7 4.5 Input features and programming limits Logic inputs (optional) Board of 2 logic inputs: 24 Vdc signal input Possible functions: In case of activation of logic input 1 and/or 2, the value EiS.1 ualue and/or EiS.2 (in display unit) will be generated. In case of simultaneous activation of the logic inputs TOR 1 and TOR 2, the value EiS.1 will be generated (logic input 1 has a priority). decre. InCrE. d.out F.out Decreasing of the output signal by the programmed step Increasing of the output signal by the programmed step Note: If Liit = YES: The decreasing or increasing will longer be possible when the analog output has reached the values d.out or F.out. If Liit = No: The decreasing or increasing will longer be possible when the analog output is < 0 or > 27.5 ma. 4.6 Features of the outputs and programming limits Out.A Analog output 0/25mA active current output Accuracy: 0.1 % in relation to the display (at +25 C) Residual ripple 0.2% Amissible load: 0Ω Lr 450Ω (current) Programmable scale ratio with enlarging effect Response time: 40 ms in relation to the display Down scale of the analog output (eg (4mA)). Full scale of the analog output (eg (20mA)) Display features Point d.disp F.diSP Place of the decimal point Display corresponding to the output down scale Display corresponding to the output full scale br.dig Adjusting of the digits brightness Lowest brightness Strongest brightness Deleting of the unsignificant zeros null = YES Suppresses the unsignificant zeros on the left hand side of the display. Eg.: Value to be displayed: 0015 Display = 0015 null = Display = 15 = YES Eg.: Value to be displayed: null = Display = Display = 0.15 = YES 4.7 Reading of the configuration read displ Out.A About Validation / vertical move read Reading of the measure display parameters Reading of the analog output parameters Reading of the logic inputs parameters (option logic inputs) Reading of the display programming parameters Reading of the instrument internal parameters In each reading submenu, use keys and to move, and key to visualise the parameters. Reminder: if key is pressed during 20 s., the instrument will revert to the measure display. p6

8 4.9 Programming of a new access code Submenu About G400 n 0 A0123 Validation / vertical move type of the instrument number of the instrument if code correct (old) P.CodE Enter previous code Enter new code if code t valid (old) display during 2s. and revert to the measure display (4) A---- A---t Analog output Analog output and 2 logic inputs ProG Pt10. Err CH.SU FC4E (4) programme version error code in case of self-diagsis error check sum of the flash memory new code recorded Revert to the measure display Reminder: If key is pressed during 1 min, the instrument will revert to the measure display Functions which can be reached from the main menu Generating of an output value 4.8 Access code An access code adjustable from 0000 to 9999 serves to protect the genera from unauthorized programming, and to lock the access to some functions. Press enu to revert to the measure display. EIS if Enter the value to be generated (value + decimal point) in display unit Facy code x x x x 0 to 5 Access to the programming of the increase step 6 to 9 No access Revert to the measure display Note: If Liit = YES and if the entered value is t comprised between d.disp and F.disp, then Err.1 will appear during 2s.: the entered value must be changed. If Liit = No and if the entered value corresponds to a value of the analog output < 0 or > 27.5 ma then Err.1 will appear during 2s.: the entered value must be changed. p7

9 Entering of the increase step 6. ERROR ESSAGES Press enu to revert to the measure display. StEP Entering of the increase step (value + decimal point (in display unit)) Err.1 O.L. Er.xxx Value set out of range Displayable value overload Self-diagsis error Revert to the measure display Note: If entered step < then Err1 appears during 2 s.: the entered step must be changed. 5. FUNCTIONS WHICH CAN BE ACCESSED DIRECTLY ON FRONT FACE DURING THE EASURING 5.1 Decreasing of the output signal 5.2 Increasing of the output signal 7. GENERAL WARRANTY TERS WARRANTY applying and duration This appliance is garanteed for a duration of 1 year against any design or manufacturing defects, under rmal operating conditions. Processing conditions * : Processing t under warranty will be submited to the acceptance of a repair estimate. The customer will return the products at his charge, and they will be resed to him after processing. Without a written agreement on the repair estimate within 30 days, products will t be held. Display of the measure Display of the measure * Complete warranty terms and details available on request. Decreasing of the output signal by a value corresponding to the increase step at each pressing Increasing of the output signal by a value corresponding to the increase step at each pressing 8. LEXIQUE essages shown by the meter in mode programming and/or in mode reading Keep pressing key or to scroll the output value quickly (quick increasing or decreasing). Note: If Liit = YES: The decreasing or increasing will longer be possible when the analog output has reached the values d.out or F.out. If Liit = No: The decreasing or increasing will longer be possible when the analog output is < 0 or > 27.5 ma. General access read ProG CodE P.CodE Access to the reading of the parameters Access to the programming of the input and output parameters Code for access to the programming of the input and output parameters Programming of a new access code p8

10 Logic inputs x Display displ. Access to the logic inputs programming submenu Programming of logic input 1 and/or 2 ualue EiS.x decre. InCrE. In case of activation of logic input 1 and/or 2, the value EiS.1 and/or EiS.2 will be generated (in display unit). In case of simultaneous activation of logic inputs 1 and 2 the value EiS.1 will be generated (priority to logic inp. 1). Value to be gener. in case of activation of logic input x Decreasing of the output signal by the programmed step Increasing of the output signal by the programmed step Access to the display programming submenu Point d.disp F.diSP Display parameters Choice of the decimal point position Place of the decimal point Display down scale Display full scale br.dig Lowest brightness 4444 null Deleting of the unsignificant zeros YES Deleting Submenu programming of the display features Adjusting of the digits brightness (4 levels) Strongest brightness No deleting Analog output Out.A SAuE Err.1 O L Er.xxx Access to the current output programming submenu d.out F.out Liit Down scale of the analog output Full scale of the analog output The analog output will t be able to pass the values d.out and F.out Liit YES The analog output can range from 0 to 27.5 ma. Saving of the configuration YES Reading of the instrument internal features About Access to the submenu reading of the internal features G400 n 0 PrOG OPtIO. A---t Err CH.Su FC4E Error messages Saving of the configuration Saving Type of the instrument: G400 A0006 Programme version Identification numbers Programme version number Option code Value of the option code Self-diagsis error Type of error Display of the check sum Value of the check sum Value set out of range Displayable value overload Self-diagsis error No saving p9

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01 Universal Flow Controller Model 261 / 261-EC-01 Instruction Manual Type ARS 261-EC 01 Art.-no: 82212264 Table of Contents 1. Safety Instructions 2. Product ID - Dimensions 3. Function Description 4. Installation

More information

Operating instructions Electronic preset counter Type series 717

Operating instructions Electronic preset counter Type series 717 Operating instructions Electronic preset counter Type series 717 1. Description 5.98.3_gb 6-digit adding/subtracting counter with two presets Very bright 8mm high LED display Counting and preset range

More information

E8Y. Micropressure Sensor with Easy-to-Read Digital Display. Differential Pressure Sensor. Ordering Information. Sensors

E8Y. Micropressure Sensor with Easy-to-Read Digital Display. Differential Pressure Sensor. Ordering Information. Sensors Differential Sensor Micropressure Sensor with Easy-to-Read Digital Repeat accuracy of ±1% FS (setting resolution: 0.01 kpa), high-precision pressure control available. Compact design (31 mm) saves mounting

More information

Electronic Pulse Counter Combination device

Electronic Pulse Counter Combination device Electronic Pulse Counter Combination device measuring monitoring analysing Input: pulse counter, time meter Display: 6-digit LED Height of digits: 14/8 mm Operation with front-panel buttons Material: plastic

More information

MULTIS L72. Operating instructions

MULTIS L72. Operating instructions GB MULTIS L72 Operating instructions 2 SOCOMEC - Ref. : 876 091B ENGLISH GB Contents PRELIMINARY OPERATIONS 4 GENERAL INFORMATION 5 PRESENTATION 4 INSTALLATION 5 Mechanical environment Climatic environment

More information

Multifunction Digital Timer

Multifunction Digital Timer Multifunction Digital Timer 72 x72 mm Timer with Easy-to-use Functions Nine output modes accommodate a wide variety of applications. All parameters set by scroll-through menus accessed from the front panel.

More information

48x24. Options ORDER NUMBER OF TYPE PFL B

48x24. Options ORDER NUMBER OF TYPE PFL B Frequency metering (0.01 Hz 9999 Hz) with 2 setpoints Free scalable indication and setpoints from 0 up to +9999 Standard: min/max memory - option: analogue output Allow to be placed side by side in grid

More information

Operating Instructions

Operating Instructions CNTX Contrast sensor Operating Instructions CAUTIONS AND WARNINGS SET-UP DISTANCE ADJUSTMENT: As a general rule, the sensor should be fixed at a 15 to 20 angle from directly perpendicular to the target

More information

AK-PVE4 Operating Instructions. Measuring of norm signals in wall-type units. Performance:

AK-PVE4 Operating Instructions. Measuring of norm signals in wall-type units. Performance: AK-PVE4 Operating Instructions Measuring of norm signals in wall-type units 1 2 P Performance: Digit heights: 20 mm Colour: red Display range: -999 9999 Wall-type housing: light grey made of ABS-plastic

More information

263 Series LED Bargraph Indicator and Controllers

263 Series LED Bargraph Indicator and Controllers 263 Series LED Bargraph Process Control Water Treatment High resolution 51 segment LED Bargraph for easy reading Accuracy 1% Red display Vertical or Horizontal mounting & stackable Connection Diagrams

More information

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV MG-XV operating instruction Measuring of norm signals, 4-8-digit Panel instrument type MG-BV Construction instrument type MG-AV Contents 1. Brief description... 3 2. Safety instructions... 3 2.1. Proper

More information

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell 99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load

More information

multi-function meters

multi-function meters multi-function meters eclipse 2 eclipse 7 installation and operating manual 1 GENERAL DESCRIPTION 2 INSTALLATION 3 WIRING INFORMATION 4 2 ECLIPSE 2 METERS 2.1 PROGRAMMING THE METER 5 2.2 INFORMATION 6

More information

Electronic converter for level transmitters MT03L Instructions manual

Electronic converter for level transmitters MT03L Instructions manual Electronic converter for level transmitters MT03L Instructions manual R-MI-MT03L Rev.: 1 English version PREFACE Thank you for choosing the MT03L converter from MT03 series of Tecfluid S.A. This instruction

More information

02/11/2015

02/11/2015 DIN Rail Mount 17.5 mm MUS/MUSF 80 AC/DC Part number 84872141 Control relays monitoring their own power supply - MUS : Over/undervoltage control Selectable latching (memory) function - MUSF : Over/undervoltage

More information

Operating Instructions (ed. 5.97) Electronic Preset Counter Type Series 904

Operating Instructions (ed. 5.97) Electronic Preset Counter Type Series 904 Operating Instructions 3.96.3 (ed. 5.97) Electronic Preset Counter Type Series 904 1. Description 6 digit preset counter, 2 presets, add./subtr. bright 2-line LCD display with symbols for activated outputs

More information

Kuhnke Technical Data. Contact Details

Kuhnke Technical Data. Contact Details Kuhnke Technical Data The following page(s) are extracted from multi-page Kuhnke product catalogues or CDROMs and any page number shown is relevant to the original document. The PDF sheets here may have

More information

DUCATI SISTEMI S. P. A. DUCA47-96 USER MANUAL

DUCATI SISTEMI S. P. A. DUCA47-96 USER MANUAL DUCATI SISTEMI S. P. A. DUCA47-96 USER MANUAL Introduction The instrument DUCA47-96 is a digital multimeter for panel mounting that allows the measurement of the principal electrical parameters in three-phase

More information

Operating Manual RISH OPTIMA VAF

Operating Manual RISH OPTIMA VAF Operating Manual RISH OPTIMA VAF 2-60-006-00-00511_Rev. A - 5/2014 Section DIGITAL MULTIFUNCTION INSTRUMENT Programmable Multi-function Digital Panel Meter Installation & Operating Instructions Contents

More information

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency, Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency, Temperature, RPM, Pressure, etc. LED/ LCD displays 1999 to 99999

More information

Weekly Time Switch. Rated time Time setting range Time division 24 hrs x 7 days 00:00 to 23:59 1min

Weekly Time Switch. Rated time Time setting range Time division 24 hrs x 7 days 00:00 to 23:59 1min Weekly Time Switch Easy Programming with Large LCD Display and Interactive Functions Programming for 24 hrs x 7 days using just five switches. Sixteen program steps available. Power supply freely selectable

More information

MODEL: 40DPT. Digital Panel Meters 40 Series. [3] OPTIONS blank: none /Q: With options (specify the specification)

MODEL: 40DPT. Digital Panel Meters 40 Series. [3] OPTIONS blank: none /Q: With options (specify the specification) Digital Panel Meters 40 Series C VOLTGE INPUT DIGITL PNEL METER (4 digit, process meter, true RMS sensing) Functions & Features 4 digit (±9999) panel meter Scaling and functions High visible, 0.8" (20.3mm)

More information

AE-341 SERIES PROCESS INDICATORS 2 TO 6 DIGITS 0-20 MA, 4-20 MA, 0-5V, OR 0-10V SCALED INPUT

AE-341 SERIES PROCESS INDICATORS 2 TO 6 DIGITS 0-20 MA, 4-20 MA, 0-5V, OR 0-10V SCALED INPUT FN: 341MAN1.DOC AE-341 SERIES PROCESS INDICATORS 2 TO 6 DIGITS 0-20 MA, 4-20 MA, 0-5V, OR 0-10V SCALED INPUT DESCRIPTION AE Series Process Indicators are available with 1", 2.3", 4", 8", or 12" high digits,

More information

Standard RS232 RS ma

Standard RS232 RS ma 1 / 5 CONTROL AND VISUALIZATION OF AC CURRENT IN SINGLE PHASE LINES BY EXTERNAL SHUNT Function Operating mode Current control Frequency control DC component control Shunt Timer Resolution Current precision

More information

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N Weekly Timer 1/4 DIN Size Timer Features Prompted Programming and Large LCD Display 24 hours x 7 days programming using just 5 switches 16 program steps and cycle operation Two independent 15 A control

More information

Operation Manual TX20 1/8 DIN Microcomputer Based ph/orp Controller with relays

Operation Manual TX20 1/8 DIN Microcomputer Based ph/orp Controller with relays Operation Manual TX20 1/8 DIN Microcomputer Based /ORP Controller with relays 11751 Markon Drive Garden Grove, CA. 92841 U.S.A. pg. 1 CONTENTS GENERAL INTRODUCTION.....3 INITIAL INSPECTION......3 USING

More information

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A and 3DPT, 10 A UL Listed when used with proper Magnecraft s The 750R series octal base, plug-in relays offer clear or full-feature covers with multiple mounting options and accessories. 750R 750R Full-Feature

More information

AX 345. Process Indicator with Two Analogue Inputs, Calculations and Programmable Analogue Output. Operating Instructions for Model AX 346

AX 345. Process Indicator with Two Analogue Inputs, Calculations and Programmable Analogue Output. Operating Instructions for Model AX 346 control motion interface motrona GmbH Zwischen den Wegen 32 78239 Rielasingen - Germany Tel. +49 (0)7731-9332-0 Fax +49 (0)7731-9332-30 info@motrona.com www.motrona.com AX 346 Process Indicator with Two

More information

Pressure Sensor. Ordering Information. Mini-Cube Pressure Sensor with Easy-to-Read LED Display

Pressure Sensor. Ordering Information. Mini-Cube Pressure Sensor with Easy-to-Read LED Display Sens Mini-Cube Sens with Easy-to-Read LED Display Industry s smallest, lightest l Both analog bar and digital pressure values are displayed Two independent outputs plus one analog output are available

More information

Figure 1: Standard 906 Sensor and Pulser Disc. Figure 2: Standard 906 Sensor and Pulser Wrap

Figure 1: Standard 906 Sensor and Pulser Disc. Figure 2: Standard 906 Sensor and Pulser Wrap Description: The TR5000 is a Full Logic Control Process ratemeter that can display up to three separate values of rate and compare them to programmable set points. Rates A & B can be programmed by the

More information

Standard signal metering in wall-mounting case

Standard signal metering in wall-mounting case User manual AKV-2VR4C Standard signal metering in wall-mounting case Technical features: Digit height: 20 mm Colour: red Range of display: -999 9999 Wall-mounting case: black, made of ABS-plastic Protection

More information

K3NX Process Meter OPERATION MANUAL

K3NX Process Meter OPERATION MANUAL Cat.No. N90 E1 1 K3NX Process Meter OPERATION MANUAL K3NX Process Meter Operation Manual Produced January 1998 Notice: OMRON products are manufactured for use according to proper procedures by a qualified

More information

User Manual M1. Thermocouple type K, B, S, N, E, T, R, L, J. Technical features:

User Manual M1. Thermocouple type K, B, S, N, E, T, R, L, J. Technical features: User Manual M1 Thermocouple type K, B, S, N, E, T, R, L, J Technical features: red display of -1999 9999 digits (optional: green, orange or blue display) minimal installation depth: from 63 mm with plug-in

More information

12months. on-site warranty. DZE ELECTRONIC PRESSURE SWITCH for detection of overload per EN 81 2 featuring two adjustable switching points

12months. on-site warranty. DZE ELECTRONIC PRESSURE SWITCH for detection of overload per EN 81 2 featuring two adjustable switching points BUCHER PRODUCTS AVAILABLE FROM HYDRATEC DZE ELECTRONIC PRESSURE SWITCH for detection of overload per EN 81 2 featuring two adjustable switching points 12months on-site warranty All our work comes with

More information

Micro-DCI 53ML5100 Manual Loader

Micro-DCI 53ML5100 Manual Loader Micro-DCI 53ML5100 Manual Loader Two process variable inputs Two manually controlled current outputs Multiple Display Formats: Dual Channel Manual Loader, Single Channel Manual Loader, Manual Loader with

More information

Process Transmitter RMA 422

Process Transmitter RMA 422 Technical Information TI 072R/24/ae Process Transmitter RMA 422 Multi-functional 1-2 channel top hat DIN rail unit with loop power supply, alarm set point monitoring, mathematics function and 1-2 analog

More information

User Manual M1. Direct current / Direct voltage signals 0-20 ma, 4-20 ma, 0-10 VDC. Technical features:

User Manual M1. Direct current / Direct voltage signals 0-20 ma, 4-20 ma, 0-10 VDC. Technical features: M1_61GB.pdf update: 17.09.2014 72x36 User Manual M1 Direct current / Direct voltage signals 0-20 ma, 4-20 ma, 0-10 VDC Technical features: red display of -1999 9999 digits (optional: green, orange or blue

More information

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm Low-cost Encoder with Diameter of 50 mm CSM DS_E An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. High-precision detection of automatic machine timing.

More information

UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4

UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4 UDC100 Universal Digital Controller 51-52-03-29 11/99 Page 1 of 4 Specification Overview The UDC100 Universal Digital Controller is a microprocessor-based 1/4 DIN low cost temperature controller. It combines

More information

ORDERING Page 6 STANDARDS, DIMENSIONS and ACCESSORIES Request bulletin SDA

ORDERING Page 6 STANDARDS, DIMENSIONS and ACCESSORIES Request bulletin SDA BE1-59NC CAPACITOR NEUTRAL OVERVOLTAGE RELAY The BE1-59NC Capacitor Neutral Overvoltage Relay provides sensitive protection for capacitor banks. ADVANTAGES Helps avoid cascading capacitor failures. Sensing

More information

MULTIS LMp / LMg. Systèmes de Coupure et de Protection Switching and Protection Systems

MULTIS LMp / LMg. Systèmes de Coupure et de Protection Switching and Protection Systems I MULTIS LMp / LMg F Notice d utilisation GB Operating instructions D Bedienungsanleitung NL Gebruiksaanwijzing Istruzioni per l uso SP Instrucciones de servicio P Manual de instruções Systèmes de Coupure

More information

AES-402 Automatic Digital Audio Switcher/DA/Digital to Analog Converter

AES-402 Automatic Digital Audio Switcher/DA/Digital to Analog Converter Broadcast Devices, Inc. AES-402 Automatic Digital Audio Switcher/DA/Digital to Analog Converter Technical Reference Manual Broadcast Devices, Inc. Tel. (914) 737-5032 Fax. (914) 736-6916 World Wide Web:

More information

LOW-COST, 3 1/2 DIGIT DC VOLTMETERS MODEL 201A & 201AN OPTION 201AN-AC / 301AN

LOW-COST, 3 1/2 DIGIT DC VOLTMETERS MODEL 201A & 201AN OPTION 201AN-AC / 301AN LOW-COST, 3 1/2 DIGIT DC VOLTMETERS MODEL 201A & 201AN OPTION 201AN-AC / 301AN STANDARD FEATURES ±1,999-count display span ±200 mv to ±200 Vdc ranges True-differential input with 80 db CMR 3-wire ratio

More information

VLC-3 USER'S MANUAL. Light Program Controller. M rev. 04 K rev. 00 & ( ( 5, 352*5$0 1 : $ 2 ' 6(77,1*6 )81&7,216

VLC-3 USER'S MANUAL. Light Program Controller. M rev. 04 K rev. 00 & ( ( 5, 352*5$0 1 : $ 2 ' 6(77,1*6 )81&7,216 Light Program Controller VLC-3 USER'S MANUAL +50,1 +50,1 1 : $ ' 2 7. 6 8 ' 5, 7 6 6. $ ( 3 352*5$0 0,16(& )81&7,216 6(77,1*6 & 8 5 5 ( 1 7 3 ( 5, 2 ' M 890-00189 rev. 04 K 895-00406 rev. 00 GENERAL...

More information

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency, Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency, Temperature, RPM, Pressure, etc. LED/ LCD displays 1999 to 99999

More information

Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features

Panel cutout required: 1.772 x 3.622 (45mm x 92mm) 1.76 (45mm) 2.45 (62mm) 3.20 (81mm) 3.60 (91mm) 0.59 (15mm) Special Features NEMA4X, IP65 Front Bezel Meter with Relays Option RELAY2 RELAY1 24V OUT POWER 4 3 2 1 6 5 2 1 2 1 NO NC COM NO NC COM RTD TC P P RTD 3 4 1 2 5 TC 6 SWITCH Rear View Gasket APM765 Panel Meter Description

More information

LAUREL ELECTRONICS, INC.

LAUREL ELECTRONICS, INC. LAUREL ELECTRONICS, INC. Laureate Digital Panel Meter for Process, Strain & Potentiometer Follower Signals Features Selectable ±0.2, ±2, ±20, ±200, ±300 & ±600 Vdc voltage ranges Selectable ±2, ±20, ±200

More information

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40 Characteristics Type of contactor LC- LC- LC- LC- LC-D & D09 D8 D2 D38 D40 D0 D9 LC-D0 DT20 & DT2 DT32 & DT40 Environment Rated insulation voltage (Ui) Conforming to IEC 947-4-, overvoltage category III,

More information

User Manual M1. Thermocouple type K, B, S, N, E, T, R, L, J. Technical features:

User Manual M1. Thermocouple type K, B, S, N, E, T, R, L, J. Technical features: User Manual M1 Thermocouple type K, B, S, N, E, T, R, L, J Technical features: red display of -1999 9999 digits (optional green, orange or blue display) minimal installation depth: 27 mm without plug-in

More information

F90 Series (Rate Indicators / Controllers) INSTRUCTION MANUAL

F90 Series (Rate Indicators / Controllers) INSTRUCTION MANUAL F90 Series (Rate Indicators / Controllers) INSTRUCTI MANUAL FEATURES DIN 48 9mm DIN 48 9mm Standard Panel Size Monitor & Preset Type 1 Monitor type with the large display 2 Preset Type can make the upper/lower

More information

CH1 CH2 CH3 CH4. Master /Fade CH5. 600s CH6. 60s SC1 SC2 SC4 SC3 SC5. SC6 Off/Pro. AL Fade 6 Pro. User guide

CH1 CH2 CH3 CH4. Master /Fade CH5. 600s CH6. 60s SC1 SC2 SC4 SC3 SC5. SC6 Off/Pro. AL Fade 6 Pro. User guide 1 1 CH1 CH2 1 1 CH4 CH 1 CH3 6s Master /Fade CH6 1 SC1 6s SC4 SC2 SC SC3 SC6 Off/Pro AL Fade 6 Pro User guide CONTENTS INTRODUCTION...2 Welcome 2 Safety 2 Supplied items 3 INSTALLATION...4 Mounting 4

More information

MT03A Electronic converter for flow rate transmitters

MT03A Electronic converter for flow rate transmitters Instructions manual MT03A Electronic converter for flow rate transmitters The art of measuring R-MI-MT03A Rev.: 0 English version PREFACE Thank you for choosing a Tecfluid S.A product. This instruction

More information

Set Point Controller OC557. Operator s Manual

Set Point Controller OC557. Operator s Manual OC557_Manual_GB1206D Set Point Controller OC557 4 20mA Input Operator s Manual METRIX ELECTRONICS LTD. Tel: +44 (0)845 034 3234 Minchens Court, Minchens Lane Fax: +44 (0)845 034 3233 Bramley, Tadley, Hampshire

More information

SCALE & WEIGHT DISPLAYS

SCALE & WEIGHT DISPLAYS The MICRO SERIES SCALE & WEIGHT DISPLAYS LARGE DIGIT MODELS Mighty-5S DPM MODELS Micro-S & Mighty-1S Mighty-1S Micro-S ELECTRO-NUMERICS, INC. Introduction The Electro-Numerics family of Digital Panel Meters

More information

INSTALLATION & OPERATING INSTRUCTIONS SINGLE/TWO CHANNEL 24HR/7 DAY TIMER. Cat No. TR671/TR672TOP

INSTALLATION & OPERATING INSTRUCTIONS SINGLE/TWO CHANNEL 24HR/7 DAY TIMER. Cat No. TR671/TR672TOP SINGLE/TWO CHANNEL 24HR/7 DAY TIMER Cat No. TR671/TR672TOP INSTALLATION & OPERATING INSTRUCTIONS TR671/TR672TOP 24Hr/7 Day 1/2 Channel Digital TOP Module (without Power Supply) Please read the instructions

More information

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description Description LAUREL ELECTRONICS, INC. Features Laureate Digital Panel Meter for Load Cell & Microvolt Input 20, 50, 100, 250 & 500 mv ranges Span adjust from 0 to ±99,999, zero adjust from -99,999 to +99,999

More information

Veeder-Root brand Series C628 Dual Preset Counter (C628-8XXX) Technical Manual

Veeder-Root brand Series C628 Dual Preset Counter (C628-8XXX) Technical Manual Introduction Your Veeder-Root brand C628 Dual Preset Counter is one model in a family of 1/8 DIN units which offers breakthrough display technology as well as easy-to-program single-line parameters. Designed

More information

Lighted Pushbutton Switch (Square) Ultra Bright LED Type

Lighted Pushbutton Switch (Square) Ultra Bright LED Type New Products Lighted Pushbutton Switch (Square) Ultra Bright LED Type Large Square-bodied Lighted Pushbutton Switches New models added with Ultra LEDs. New models with ultra bright LEDs added to single-screen

More information

USER MANUAL. Compact dimensions 6 DIN modules, with 4 LED s display with 7 segments, for an excellent reading of the measurements

USER MANUAL. Compact dimensions 6 DIN modules, with 4 LED s display with 7 segments, for an excellent reading of the measurements DUCATI SISTEMI S. P. A. DUCA47 USER MANUAL Introduction The instrument DUCA47 is a digital multimeter that allows the measurement of the principal electrical parameters in threephase 230/400Vac networks

More information

INDEP. QUARTZ MIN. - 1/2 MIN. AFNOR / IRIG B DHF / RADIO

INDEP. QUARTZ MIN. - 1/2 MIN. AFNOR / IRIG B DHF / RADIO Style 12 INDEP. QUARTZ MIN. - 1/2 MIN. AFNOR / IRIG B DHF / RADIO INSTALLATION AND OPERATING INSTRUCTIONS B.P. 1 49340 TRÉMENTINES FRANCE Tél. : 02 41 71 72 00 Fax : 02 41 71 72 01 www.bodet.com Réf. :

More information

INSTRUCTIONS FOR USE Pro-Ject Tuner Box S2

INSTRUCTIONS FOR USE Pro-Ject Tuner Box S2 INSTRUCTIONS FOR USE Pro-Ject Tuner Box S2 Dear music lover, thank you for purchasing a Pro-Ject Audio Systems FM-tuner. In order to achieve maximum performance and reliability you should study these instructions

More information

Operating Manual. Basic Control BC16. two-channel for eco moon

Operating Manual. Basic Control BC16. two-channel for eco moon Operating Manual Basic Control BC16 two-channel for eco moon Dear Customer, Thank you for choosing a WALTRON daytime lighting controller. Your daytime lighting controller is a high-quality product that

More information

MultiMac SM. Eddy Current Instrument for Encircling Coil, Sector and Rotary Probe Testing of Tube, Bar, & Wire

MultiMac SM. Eddy Current Instrument for Encircling Coil, Sector and Rotary Probe Testing of Tube, Bar, & Wire MultiMac SM Eddy Current Instrument for Encircling Coil, Sector and Rotary Probe Testing of Tube, Bar, & Wire Features of the MultiMac SM Electronics Simultaneous Coil and/or Rotary Probe operation Differential

More information

Bedienungsanleitung KCT2-6ST-V KC-LED-96-1T-24VDC

Bedienungsanleitung KCT2-6ST-V KC-LED-96-1T-24VDC FABRIKAUTOMATION Bedienungsanleitung KCT2-6ST-V Elektronischer Anzeigenzähler Pulse counter/position indicator Compteurs à affichage électroniques Contatori con display elettronici Contadores indicadores

More information

ST-4000D SIGNAL LEVEL METER

ST-4000D SIGNAL LEVEL METER ST-4000D SIGNAL LEVEL METER Rev 100606 Table of Contents Features / Specifications.... 1 Keypad Illustration....... 2 Keypad Controls.... 2 Getting Started: Powering the Meter...... 3 Quick Use Instructions.....

More information

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module Helvar Data is subject to change without notice. www.helvar.com i Contents Section Page Introduction 1 Installation 2 1. Attach

More information

OPERATION MANUAL JENDPM008 THERMOCOUPLE PANEL THERMOMETER. TIP TEMPerature Products 340 W Broad Street Burlington, NJ 08016

OPERATION MANUAL JENDPM008 THERMOCOUPLE PANEL THERMOMETER. TIP TEMPerature Products 340 W Broad Street Burlington, NJ 08016 OPERATION MANUAL JENDPM008 THERMOCOUPLE PANEL THERMOMETER TIP TEMPerature Products 340 W Broad Street Burlington, NJ 08016 1-800-TIP-TEMP Tel. (609) 239-1900 Fax (609) 239-1911 www.tiptemp.com GENERAL

More information

2 MHz Lock-In Amplifier

2 MHz Lock-In Amplifier 2 MHz Lock-In Amplifier SR865 2 MHz dual phase lock-in amplifier SR865 2 MHz Lock-In Amplifier 1 mhz to 2 MHz frequency range Dual reference mode Low-noise current and voltage inputs Touchscreen data display

More information

KNX Dimmer RGBW - User Manual

KNX Dimmer RGBW - User Manual KNX Dimmer RGBW - User Manual Item No.: LC-013-004 1. Product Description With the KNX Dimmer RGBW it is possible to control of RGBW, WW-CW LED or 4 independent channels with integrated KNX BCU. Simple

More information

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI ATEX category II 1 G, Ex-zone 0 ATEX category II 2 D, Ex-zone 21 Threaded barrel, M18 x 1 Chrome-plated brass 2-wire, 14 30 VDC Analog output 4 20 ma Cable connection Wiring diagram Type code Ident no.

More information

SC-HD-2A HDMI Scaler & Audio Embedder / Extractor

SC-HD-2A HDMI Scaler & Audio Embedder / Extractor User s Manual SC-HD-2A HDMI Scaler & Audio Embedder / Extractor Scale HDMI or DVI video Embed Digital or Analog Audio into HDMI output Extract (De-embed) Digital and Analog Audio from HDMI input UMA1246

More information

Model Number Structure

Model Number Structure Cycle Control Units CSM DS_E_7_1 Refer to Safety Precautions for All Power Controllers. Used in Combination with the to Enable High-precision Temperature Control Use cycle control to achieve power control

More information

Magnecraft Power Relays

Magnecraft Power Relays Description DPST-NO, 30 A; DPDT, 30 A (NO) / 3 A (NC) Description The series power relays offer a small package size and features Class F insulation for a maximum coil temperature of 55 C (3 F). These

More information

Operating Instructions

Operating Instructions COUNTERS CONTROLLERS ENCODERS Operating Instructions Electronic Preselection Counter Two preselections NE 216 Contents Page 1 Safety indications... 2 2 Get to know your NE 216... 4 2.1 NE216 components...

More information

APPLICATIONS. Automatic warehouse. Trasportation lines

APPLICATIONS. Automatic warehouse. Trasportation lines INDUCTIVE TUBULAR SENSOR M12 SERIES There are millions of inductive sensors deployed in almost every area of factory automation. They detect metal objects contactless and are distinguished by a long operating

More information

AS09..S 3-pole Contactors - Spring Terminals

AS09..S 3-pole Contactors - Spring Terminals 4 kw 5 hp AS09..S 3-pole Contactors - Spring AC Operated Description - 3-pole contactors with spring terminals, - N.C. or N.O. built-in auxiliary contact, - Rail-mounted, no tools required, - Additional

More information

MultiMac. Eddy Current Instrument for Encircling Coil, Sector and Rotary Probe Testing of Tube, Bar, & Wire

MultiMac. Eddy Current Instrument for Encircling Coil, Sector and Rotary Probe Testing of Tube, Bar, & Wire MultiMac Eddy Current Instrument for Encircling Coil, Sector and Rotary Probe Testing of Tube, Bar, & Wire Inspection Features Versatile Threshold Selection Challenging test conditions are made simple

More information

ED3. Digital Encoder Display Page 1 of 13. Description. Mechanical Drawing. Features

ED3. Digital Encoder Display Page 1 of 13. Description. Mechanical Drawing. Features Description Page 1 of 13 The ED3 is an LCD readout that serves as a position indicator or tachometer. The ED3 can display: Speed or position of a quadrature output incremental encoder Absolute position

More information

Triple RTD. On-board Digital Signal Processor. Linearization RTDs 20 Hz averaged outputs 16-bit precision comparator function.

Triple RTD. On-board Digital Signal Processor. Linearization RTDs 20 Hz averaged outputs 16-bit precision comparator function. Triple RTD SMART INPUT MODULE State-of-the-art Electromagnetic Noise Suppression Circuitry. Ensures signal integrity even in harsh EMC environments. On-board Digital Signal Processor. Linearization RTDs

More information

Sprite TL Quick Start Guide

Sprite TL Quick Start Guide Sprite TL Quick Start Guide with 115 VAC Power Cord and 4-Conductor Signal Cable Reference Manual Sprite TL Online and downloadable Product Manuals and Quick Start Guides are available at www.hydrosystemsco.com

More information

SECTION 8. Counters & Timers. Laurel Hecon Simpson Yokogawa (YCA)

SECTION 8. Counters & Timers. Laurel Hecon Simpson Yokogawa (YCA) SECTION Counters & Timers (Analog / Digital) Laurel Hecon Simpson Yokogawa (YCA) Counters and Timers from the following manufacuturers are also available but not shown in catalog: Texmate Triplett (LFE)

More information

Hybrid Chart Recorder 250 mm (10")

Hybrid Chart Recorder 250 mm (10) Hybrid Chart Recorder 250 mm (10") RD5100 Series U High Speed Scanning at 36 Points/Sec and High-Speed Recording U High Accuracy of 0.05% U Various Industrial Values Can be Measured at the Same Time with

More information

2 WIRE - LOOP POWERED TRANSMITTER FOR PT100 AND NI100 PROBES

2 WIRE - LOOP POWERED TRANSMITTER FOR PT100 AND NI100 PROBES EN K20RTD 2 WIRE - LOOP POWERED TRANSMITTER FOR PT00 AND NI00 PROBES General Description The K20RTD instrument converts a temperature signal read by a PT00 (EN 60 75) or NI00 probe with connection by 2,

More information

GAUGEMASTER PRODIGY EXPRESS

GAUGEMASTER PRODIGY EXPRESS GAUGEMASTER PRODIGY EXPRESS DCC01 USER MANUAL Version 1.2 2014 1 T A B L E O F C O N T E N T S 1 Getting Started Introduction Specifications and Features Quick Start Connecting to Your Layout Running a

More information

Product Guide. Analog Panel Meters for use in Electrical Engineering Systems. M Series. Instruments clamping to 35 mm DIN rails W/P/ LSP BWQ BGQ

Product Guide. Analog Panel Meters for use in Electrical Engineering Systems. M Series. Instruments clamping to 35 mm DIN rails W/P/ LSP BWQ BGQ Product Guide Analog Panel Meters for use in Electrical Engineering Systems M Series 200.U.001.05 M Series W/P/ LSP Instruments clamping to 35 mm DIN rails BWQ BGQ TP TG WQ /0S WQ /2S FQ /2 W BI BIW SY

More information

3.5. Control Relays and Timers. Contents. 9575H Series 3000 Type AA, AC and DC. General Purpose Relays Type AA

3.5. Control Relays and Timers. Contents. 9575H Series 3000 Type AA, AC and DC. General Purpose Relays Type AA .5 9575H Series 000 Relay Contents 9575H Series 000 Type AA, AC and DC Product Selection....................... Accessories............................ Technical Data and Specifications........... Dimensions............................

More information

ST-4000 SIGNAL LEVEL METER

ST-4000 SIGNAL LEVEL METER ST-4000 SIGNAL LEVEL METER Table of Contents Features / Specifications.... 1 Keypad Illustration....... 2 Keypad Controls.... 2 Getting Started: Powering the Meter.... 3 Quick Use Instructions.. 3 Main

More information

FlexiScan. Impro FlexiScan 4-Channel Controller INSTALLATION MANUAL

FlexiScan. Impro FlexiScan 4-Channel Controller INSTALLATION MANUAL MODEL NUMBER: HCM991-0-0-GB-XX FlexiScan SPECIFICATIONS Impro FlexiScan 4-Channel Controller INSTALLATION MANUAL Working Environment... Security... Input Voltage... The Impro FlexiScan is designed to work

More information

ORDERING Page 6 BASLER RELAY STANDARDS, DIMENSIONS, ACCESSORIES Request bulletin SDA

ORDERING Page 6 BASLER RELAY STANDARDS, DIMENSIONS, ACCESSORIES Request bulletin SDA BE1-59NC CAPACITOR NEUTRAL OVERVOLTAGE RELAY The BE1-59NC Capacitor Neutral Overvoltage Relay provides sensitive protection for capacitor banks. ADDITIONAL INFORMATION INSTRUCTION MANUAL ADVANTAGES Helps

More information

AES-404 Digital Audio Switcher/DA/Digital to Analog Converter

AES-404 Digital Audio Switcher/DA/Digital to Analog Converter Broadcast Devices, Inc. AES-404 Digital Audio Switcher/DA/Digital to Analog Converter Technical Reference Manual Broadcast Devices, Inc. Tel. (914) 737-5032 Fax. (914) 736-6916 World Wide Web: www.broadcast-devices.com

More information

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area Guide for installers METTLER TOLEDO MultiRange System solution analog Ex1 Hazardous area Safe area System solution analog Ex1 Contents Contents Page 1 Safety precautions... 2 2 System overview... 3 2.1

More information

Dimming actuators GDA-4K KNX GDA-8K KNX

Dimming actuators GDA-4K KNX GDA-8K KNX Dimming actuators GDA-4K KNX GDA-8K KNX GDA-4K KNX 108394 GDA-8K KNX 108395 Updated: May-17 (Subject to changes) Page 1 of 67 Contents 1 FUNCTIONAL CHARACTERISTICS... 4 1.1 OPERATION... 5 2 TECHNICAL DATA...

More information

45 Hz to 500 Hz 1.0% Hz to 1 khz 2.0% + 3. Accuracy 0.09% + 2. Range / resolution. Range / resolution. Accuracy 1% + 2

45 Hz to 500 Hz 1.0% Hz to 1 khz 2.0% + 3. Accuracy 0.09% + 2. Range / resolution. Range / resolution. Accuracy 1% + 2 AC Voltage Range¹ / resolution 2 3 4 45 Hz to 500 Hz 1.0% + 3 500 Hz to 1 khz 2.0% + 3 600.0 mv / 0.1 mv 6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V 1000 V / 1 V 1. All AC voltage ranges are specified

More information

INSTRUCTIONS FOR USE Pro-Ject Tuner Box S

INSTRUCTIONS FOR USE Pro-Ject Tuner Box S INSTRUCTIONS FOR USE Pro-Ject Tuner Box S Dear music lover, thank you for purchasing a Pro-Ject Audio Systems FM-tuner. In order to achieve maximum performance and reliability you should study these instructions

More information

ProVu PD6000 Process Meter

ProVu PD6000 Process Meter Congratulations on your purchase of the ProVu PD6000 process meter! This quick start guide will briefly describe some of the common setup procedures for this meter. This guide includes: Basic Wiring for

More information

AT450SAW Programmable Selective Amplifier

AT450SAW Programmable Selective Amplifier AT450SAW Programmable Selective Amplifier LEMELETTRONICA srl Via Grezze 38 25015 Desenzano del Garda (BS) ITALY Tel. +39 030-9120006 Fax +39 030-9123035 www.lemelettronica.it Technical Specifications

More information

LM/TM-30xx, 31xx Series LCD Monitor User s Manual Rev. A0

LM/TM-30xx, 31xx Series LCD Monitor User s Manual Rev. A0 LM/TM-30xx, 31xx Series LCD Monitor User s Manual Rev. A0 FCC NOTICE This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions

More information

XTM72E & F Real-Time Clock Modules

XTM72E & F Real-Time Clock Modules Capricorn Controls Ltd Data & Application Notes Page 1 of 8 XTM72E & F Real-Time Clock Modules Originally designed to compliment our wide range of Gen-Set controls, these DC powered Real-Time-Clocks have

More information

SINCE User Manual 7 DAY PROGRAMMABLE DIGITAL TIMER MODEL PS-100. The best solutions for automation and protection.

SINCE User Manual 7 DAY PROGRAMMABLE DIGITAL TIMER MODEL PS-100. The best solutions for automation and protection. SINCE 1973 User Manual 7 DAY PROGRAMMABLE DIGITAL TIMER MODEL PS-100 The best solutions for automation and protection www.nassarelectronics.com Description The PS-100 is a 7 day programmable digital timer

More information

Industriefunkuhren. Technical Manual. IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C / AFNOR NF S87-500

Industriefunkuhren. Technical Manual. IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C / AFNOR NF S87-500 Industriefunkuhren Technical Manual IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C37.118 / AFNOR NF S87-500 Module 7628 ENGLISH Version: 02.01-06.03.2013 2 / 20 7628 IRIG-B

More information