video door entry system - installation instructions

Size: px
Start display at page:

Download "video door entry system - installation instructions"

Transcription

1 4 TRADE 007 AUDIO 008 VIDEO Tel : Fax : WEB : oronation Road Park Royal, London NW0 7QJ video door entry system installation instructions IN008v 0008 Getting started Thank you for choosing SRS. If you are installing this system with one entrance panel continue to step. If however you are installing more than one entrance please follow the instructions (IN4) supplied with the multi entrance relay box. Install the cables Use W08 (BT spec.) twisted paired and RG coaxial cable. See cable layout fig.. Any cable joint is potentially a cause of connection faults, it is therefore prudent to keep junctions to a minimum. For this reason we recommend making connections at the panel (max. telephones) or at ONE point in the riser (usually adjacent to the ). fig. video layout 7n 7 7 Install the video phones The video phones should be connected according to the diagram overleaf. Ignore the dashed wires if additional features are not required. If additional video phones are required to be called simultaneously, please refer to Fig.. fig. 00mm 4 Install the entrance panel Please refer to the instructions (IN4000) supplied with the door entry panel. Operation The video door entry system functions as follows. Upon pressing one of the external buttons the corresponding video phone sounds (only when on hook), the screen will light and display the image from the camera. When the called phone handset is picked up, contact is established and conversation may take place. In order to operate the electric lock the push button marked by a key symbol should be fully depressed. Two other buttons (AN70) are provided for auxiliary use. The picture will stay lit for a preset period ( seconds to minutes) adjustable at the 008 PSU. 007 functions The 007 unit (PSU) has built in lock release timer (with relay output), v ac, v dc, and tone outputs. When the lock release button on the phone is pressed, terminal and (at the phone) are shorted, causing the lock release timer to start which in turn changes the state of the relay. The time can be adjusted between 40 seconds (approx.). The v ac (A) and v dc () terminals may be used to power lock releases up to 0. Amps. ac/dc = number of cores n = number of phones = RG oaxial cable If the installation is for a single apartment (with monitor), or a block of apartments on a single riser (with monitor per apartment) AN00 video distributor is not necessary. However for all other installations it is recommended that the distributor is fitted. See fig. 4. AN70 & AN770S (AN70) and slides into the side of the monitor (AN770S) V V R R Three monitors may be called simultaneously. For simultaneous call add local (AN48S) for each additional monitor. W08 fig. calling more than video monitor M AN48S Local PSU From previous video monitor Alternative diagrams & data sheets are available. all or visit D ME entrance basic system diagram over leaf D ME entrance system with video phones (simultaneous call) D nme entrance system (without Trades button) D nmed entrance system (with Trades button) diagram over leaf D nme entrance system (without Trades button) D nmne multi entrance system (without Trades button) E requirements This product was tested for compliance with E directive 8//EE with the panel connected to Earth. Always ensure that external metal parts are independently connected to mains protective earth to avoid electrical shock hazard. dio Door Entry Systems Video Door Entry Systems Keypads Access ontrol Systems Electric Locking & Accessories SRS Wholesale Limited registered in England No: 4 T No: 4

2 R e m e m b e r Always fit the lock supressor supplied, SRS TZ. This device must be connect ed to a l l electric locks and electric releases. Fit directly across the lock ter m i n a l s. Trouble shooting The first rule of trouble shooting is to make your system as simple as possible. ie. remove any nonessential conn e c t i o n s. No picture (the monitor lights up) a heck for V at the camera b heck video signal c heck correct connection of video distributor if used No picture (monitor won t light up) a In order for the monitor to light it must be called and get 8V from the PSU. b heck for a call tone at the monitor c heck for 8V on R (ve) & R (ve), both at the PSU and more i m p o r t a n t l y, at the monitor. Poor picture a Failure to fit end of line resistors. For systems w i t h o u t video distributor (AN00) ONE resistor should be fitted across V & V of the last monit o r. For systems w i t h video distributor O N E resistor should be fitted across V & V of the last monitor for each output ( in total if one distributor fitt e d ). b Low power to the video monitor. heck for 8 volts between R and R (ve) at the monitor when the monitor has been called. If the voltage is less than volts then picture quality will be poor. In this case check for overall load (max amp) and cross sectional area of the R & R wires. High pitched screech: a Excessive amplification (volume requires adjustment) b Unhooked handset hanging down & facing wall c Short circuit on wires & d Incorrect cable used e Poor alignment of microphone to hole in front plate. No speech a heck for short circuits and/or breaks on wires &. b heck V dc at speaker unit Lock release will not trigger a heck lock connections b Remove cable(s) from at the 007 (PSU). Trigger input with egress button. If this corrects the fault, check wire to telephone. c With a meter check lock relay output is changing state. fig. 4 connection of video distributor telephone (AN70) and slides (AN770S) telephone (AN70) and slides (AN770S) telephone (AN70) and slides (AN770S) telephone (AN70) and slides (AN770S) V V V4 Out IN Video to monitor Video to monitor Video to monitor Video to monitor 4 Video OUT To IN of next AN00 (or fit resistor across OUT and ) Video IN V V R R V V R R V V R R V V R R SRS Video amera 008 VIDEO

3 D M E Video Diagram Monitors Entrances One entrance video door entry system calling monitor..04 AN70 & AN770S (AN70) and slides into the side of the monitor (AN770S) V V R R W08 Installation Notes : able requirements : Maximum recommended overall distance for W08 BT spec. twisted paired cable run is 00 metres. For longer cable runs up to 0 metres the cables R & R should be.mm dia. interference. The action of making a call will draw current from at the 008. The timed output R (8vdc) is started. The monitor can be lit only whilst the timer is running and a call has been made. Video Telephone Three monitors may be called simultaneously. For simultaneous call add local (AN48S) for each additional monitor, as shown. A video distributor (AN00) is also recommended if an additional monitor is called simultaneously. TWO wires for terminal of the telephone. White / Green & are shown. This is intentional and should be followed for best results. Two push buttons are available for other functions (eg. opening a second lock) marked / & Q/Q. These are both push to make momentary switches. all button 008 VIDEO 008V Video PSU R R Speaker Unit T amera Unit Z 0 A V A fail locked A V fail locked V fail open N/ GND N/ OM v A V A FAIL LOKED illustrated

4 D nm E D Video Diagram Monitors Entrances Distributor One entrance video door entry system calling n monitors..0 Installation Notes : Video Note Fit resistor at each monitor if using AN00 as shown. AN70 & AN770S (AN70) and slides into the side of the monitor (AN770S) V V R R W08 able requirements : It is recommended that cables are star wired to the video monitors from a central point Maximum recommended overall distance for W08 BT spec. twisted paired cable run is 00 metres. For longer cable runs up to 0 metres the cables R & R should be.mm dia. interference. The action of making a call will draw current from at the 008. The timed output R (8vdc) is started. The monitor can be lit only whilst the timer is running and a call has been made. Video Telephone Three monitors may be called simultaneously. For simultaneous call add local (AN48S) for each additional monitor. AN70 & AN770S (AN70) and slides into the side of the monitor (AN770S) V V R R W08 TWO wires for terminal of the telephone. White / Green & are shown. This is intentional and should be followed for best results. Two push buttons are available for other functions (eg. opening a second lock) marked / & Q/Q. These are both push to make momentary switches. Optional keypad The programmable keypad is an option which when ordered can be built into the panel or supplied as a separate unit. Set the lock time on the keypad for sec. The actual lock operating time is set by the timer on the 007. AN70 & AN770S W08 (AN70) and slides into the side of the monitor (AN770S) V V R R AN00 Video Distributor V RG oax V RG oax all buttons V4 Out IN RG oax RG oax Master Fit resistor across Out & Gnd of last AN00 RG Speaker Unit T amera Unit V A fail A V fail V fail open N/ 008V lock timer relay (40s) V FAIL LOKED illustrated with transil fitted

5 D M E /04 Video Diagram Monitors Entrances One entrance video door entry system calling monitor keypad..04 Installation Notes : AN70 & AN770S (AN70) and slides into the side of the monitor (AN770S) V V R R W08 W08 able requirements : Maximum recommended overall distance for W08 BT spec. twisted paired cable run is 00 metres. For longer cable runs up to 0 metres the cables R & R should be.mm dia. interference. The action of making a call will draw current from at the 008. The timed output R (8vdc) is started. The monitor can be lit only whilst the timer is running and a call has been made. Video Telephone Three monitors may be called simultaneously. For simultaneous call add local (AN48S) for each additional monitor. Note: If using AN777 telephone in place of AN70. onnect as per AN70 except add the following: onnect terminal to v (007. terminal ) If door monitoring is required. onnect terminal 8 to v (007. terminal ) via a door monitor microswitch. A video distributor (AN00) is also recommended if an additional monitor is called simultaneously. TWO wires for terminal of the telephone. White / Green & are shown. This is intentional and should be followed for best results. Two push buttons are available for other functions (eg. opening a second lock) marked / & Q/Q. These are both push to make momentary switches. Keypad The programmable keypad is an option which when ordered can be built into the panel or supplied as a separate unit. Set the lock time on the keypad (default is secs) all button Speaker Unit 008 VIDEO 008V video all Tone v ac A 0 Volts 0 v dc Intercom 07/ R R Z RG oax & T amera Unit Built in Keypad optional v 0v N Tmlk OM EGR PSU V A fail A V fail V fail open N/ Relay shown for fail locked

6 D Video Diagram nm E /4 D Monitors Entrances keypad Distributor Two entrance (with Trades button) video door entry system calling n monitors with video distribution..04 To further monitors AN70 & AN770S (AN70) and slides into the side of the monitor (AN770S) V V R R Use W08 cable twisted pairs minimum Installation Notes: Ignore dashed wires if not required. able Requirements interference. W08 is suitable for distances up to 00 metres. For longer cable runs you should increase the dimensions of the cores according to the chart. Wire metres Trm Function Loudspeaker Microphone ommon ve Lock release all tone R monitor power (ve).0.. R monitor power (8v).0.. Diameter of conductors mm AN70 & AN770S (AN70) and slides into the side of the monitor (AN770S) V V R R AN00 Video Distributor for 4 monitors V V V4 Out IN Use W08 cable twisted pairs minimum Video to monitor Video to monitor Video to monitor Video to monitor 4 To IN of next AN00 Master White / Green & white / blue TWO wires for terminal of the telephone. White / Green & are shown. This is intentional and should be followed for best results. 4 entrance relay When current is drawn from PS (entrance A or B) the relay will latch to the calling entrance for approx. 0 seconds or the duration of the call (whichever is longer). The other entrance, if calling, will hear an engaged tone. Site the (07) close to the relay (4). Two push buttons are available for other functions (eg. opening a second lock) marked / & Q/Q. These are both push to make momentary switches. / terminal The / terminal is a connection which can be used instead of terminal. If you are experienceing feedback (and you are sure it not a connection problem) then the / terminal is used to half the volume of the telephone earpiece. Use with caution Optional keypad The programmable keypad is an option which when ordered can be built into the panel or supplied as a separate unit. TR TR 4 OM all buttons Trade button if fitted TR TR 4 Brown OM Trade button if fitted all buttons TRADE Speaker Unit T amera Unit Built in Keypad optional v 0v N Tmlk OM EGR Brown / White oax PS V V N V V EA EB 4 entrance relay RELAY 4 entrance relay 0 PS V V N I Brown / White oax Speaker Unit T amera Unit TRADE PSU V A fail A V fail V fail open N/ V A fail A V fail V fail open N/ R R Z 0 A onnection shown V fail locked GND N/ OM onnection shown V fail locked 008V lock timer relay (40s)

TeleHawk Door entry system

TeleHawk Door entry system Veermount Technology Limited TeleHawk Door entry system INSTALLATION MANUAL (For product supplied after January 1st, 2006) IMPORTANT NOTE. Long term system reliability and low maintenance costs can only

More information

1 EX5. Technical Characteristics. Dimensions

1 EX5. Technical Characteristics. Dimensions These robust IP rated standalone keypads are designed to operate in both internal and external environments. EX5 Keypads include backlit metallic or plastic keys with a choice of plastic or metal housings

More information

Art M Digital codelock module

Art M Digital codelock module CODELOCK UNIT MODULES Art. 4900-4900M This module has on the front a 12 stainless steel button keypad (keys from 0 to 9 plus ENTER and CLEAR keys), 2 LEDS for operation signalling, the keypad illumination

More information

Aspect 2 Circuit Digital Scene Control

Aspect 2 Circuit Digital Scene Control Aspect 2 Circuit Digital Scene Control S p e c i f i c a t i o n 2 circuits of trailing edge dimming 500W total between the two circuits Both circuits feature independent overload, short-circuit and open-circuit

More information

Installation & User Manual For. Styluscom. Wired Video Intercom System. Models StylusAB, StylusABK, StylusAS Manual Version 1.

Installation & User Manual For. Styluscom. Wired Video Intercom System. Models StylusAB, StylusABK, StylusAS Manual Version 1. Installation & User Manual For Styluscom Wired Video Intercom System Models StylusAB, StylusABK, StylusAS Manual Version 1 P a g e 1 Contents Overview of system.pg 3 Site Survey.Pg 3 SIM card.pg 3 Power.Pg

More information

CABLE SIZE AND INSTALLATION GUIDE

CABLE SIZE AND INSTALLATION GUIDE CABLE SIZE AND INSTALLATION GUIDE EDITION 1.0 CONTENTS PAGE Cable Guide Introduction 3 Cable Types 3-4 Acceptable Cables 4-5 Video System Cables 5 High Voltage and Low Voltage Cables 6 Audio Systems (3+1

More information

Access Control Keypad for MK-DV, JB-DV

Access Control Keypad for MK-DV, JB-DV #91173 0406 Access Control Keypad for MK-DV, JB-DV - INSTRUCTIONS - The KVI is a surface mount electronic access control keypad for use with Aiphone s MK-DV or JB-DV video door station. Designed with the

More information

ACT 10 Digital Keypad Operating & Installation Instructions This manual is found at

ACT 10 Digital Keypad Operating & Installation Instructions This manual is found at ACT 10 Digital Keypad Operating & Installation Instructions 18-00001 This manual is found at www.eaglesecuritysolutions.co.uk Installation Notes Always remember to factory default the controller before

More information

Two (2) Channel 365 Day 24 Hr. Timer/Controllers

Two (2) Channel 365 Day 24 Hr. Timer/Controllers Two (2) Channel 365 Day 24 Hr. Timer/Controllers Models include: PT2724 - Timer module PT2724E - Timer module in enclosure Installation Guide Rev. 020317 More than just power. TM Overview: Altronix PT2724/PT2724E

More information

Overview: Specifications: Installation Instructions:

Overview: Specifications: Installation Instructions: Overview: The SignalGuys.com Start/Stop Work Timer PT724A is an extremely versatile 24 Hour 365 Day Event Timers designed to support a wide range of applications. Such applications include: Start/Stop

More information

HS-509 VIBRATION TRIP MODULE

HS-509 VIBRATION TRIP MODULE HS-509 VIBRATION TRIP MODULE 1. Overview The HS-509 is a configurable trip amplifier capable of accepting a 4-20mA signal from a HS-420 sensor and providing two trip action relay outputs along with an

More information

Description Diagram Page

Description Diagram Page notiziario tecnico 2004 SISTEMA VIDEO 4+n installation wiring diagrams VIDEO SYSTEM 4+n INDEX: Description Diagram Page Section of wires 2/UK Suggestions for the correct installation 3/UK Terminal functions

More information

CAMTO LTD. Arc detecting system DC/AC

CAMTO LTD. Arc detecting system DC/AC CAMTO LTD Arc detecting system DC/AC Arc detecting system DC/AC The system is based on experience with arc protection since 1962. The system units are built into boxes that all fit on a 35 mm DIN-rail.

More information

Operating instructions Electronic preset counter Type series 717

Operating instructions Electronic preset counter Type series 717 Operating instructions Electronic preset counter Type series 717 1. Description 5.98.3_gb 6-digit adding/subtracting counter with two presets Very bright 8mm high LED display Counting and preset range

More information

PT Two (2) Channel 365 Day 24 Hr. Timer/Controller

PT Two (2) Channel 365 Day 24 Hr. Timer/Controller PT2724 - Two (2) Channel 365 Day 24 Hr. Timer/Controller Overview: This unit is an extremely versatile two channel 365 Day 24 Hour Timer / Controller designed to support a wide range of applications. Such

More information

Unlocking of building entrance door shall be possible by pressing the monitor's door-opener button.

Unlocking of building entrance door shall be possible by pressing the monitor's door-opener button. DIGITAL COLOR VIDEO INTERCOM SYSTEM The contractor shall supply, install, test and commission a modern Electronic Digital Color Video Entry Phone System of an approved manufacturer and design to facilitate

More information

Product information. Front-door station series with video for surface-mount

Product information. Front-door station series with video for surface-mount Product information Front-door station series with video for surface-mount series VPES series VPDS 2 05/2006 Table of contents Scope of delivery...3 Safety notices...3 General notes on the cabling in TCS

More information

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) * EE-SX/6 Photomicrosensor with 0- to 00-mA direct switching capacity for built-in application. Series includes models that

More information

Single Axis Position Controller

Single Axis Position Controller SERIES P9511 Single Axis Position Controller Compact Construction Simple Go-to operation Integrated Relay Output Integrated Mains Power Supply ELEKTRO-TRADING sp. Z o.o. 44-109 Gliwice, ul. Mechaników

More information

SSPT724A Timer Quick Start Guide

SSPT724A Timer Quick Start Guide SSPT724A Timer Quick Start Guide Open timer enclosure and remove mounting parts and instructions. When ready to program the timer, plug in timer to 120 Volt Ac power receptacle Press the SET button to

More information

MBUS 10 RS232 TO MBUS LEVEL CONVERTER

MBUS 10 RS232 TO MBUS LEVEL CONVERTER Media and protocol converters MBUS 10 RS232 TO MBUS LEVEL CONVERTER RS232 to MBus level conversion Maximum 10 MBus slaves Baud Rate: 300 to 19200 bps RS232 MBus opto isolation Over-current and short-circuit

More information

USER S GUIDE. 1 Description PROGRAMMABLE 3-RELAY LOGIC MODULE

USER S GUIDE. 1 Description PROGRAMMABLE 3-RELAY LOGIC MODULE 1 Description The is a programmable 3 relay logic module that may be used for multiple applications, including simple timing, door mounted sensor inhibiting and advanced relay sequencing. The contains

More information

1 Overview. 2 Specifications. 3 Installation Instructions. HPT724 Programmable LCD Timer PN 52765:A 1/25/06 ECN Product Installation Document

1 Overview. 2 Specifications. 3 Installation Instructions. HPT724 Programmable LCD Timer PN 52765:A 1/25/06 ECN Product Installation Document Honeywell 12 Clintonville Road Northford, CT 06472 http://www.honeywellpower.com HPT724 Programmable LCD Timer PN 52765:A 1/25/06 ECN 05-637 1 Overview Product Installation Document The Honeywell HPT724

More information

Art M Digital codelock module

Art M Digital codelock module CODELOCK UNIT MODULES Art. 4800-4800M The module features 12 stainless steel buttons (Keys 0-9, ENTER and CLEAR), 2 LED s for progress information during use and programming and a mirror finish stainless

More information

Operating Instructions

Operating Instructions CNTX Contrast sensor Operating Instructions CAUTIONS AND WARNINGS SET-UP DISTANCE ADJUSTMENT: As a general rule, the sensor should be fixed at a 15 to 20 angle from directly perpendicular to the target

More information

Heating thermostat Series AMHs B Operating Instructions 11.06/

Heating thermostat Series AMHs B Operating Instructions 11.06/ Heating thermostat Series AMHs-1-80 B 60.3045.0 Operating Instructions 11.06/ 00367556 Typographical conventions Warning signs The signs for Danger and Warning are used in this manual under the following

More information

Modular Lube Lubrication Systems System Controls

Modular Lube Lubrication Systems System Controls Model 84501 Program Timer Solid State Designed to control the lubrication cycle frequency of air-operated single-stroke pumps. Timer turns pump on/off at programmed intervals via a 3-way or 4-way air solenoid

More information

Art. VR4KCLM-1 - VRCLM Digital codelock

Art. VR4KCLM-1 - VRCLM Digital codelock Fig. 1 VR4KCLM-1 Fig. 2 VRCLM CODELOCK UNIT MODULES The module features 12 stainless steel buttons (Keys 0-9, and CLEAR), 2 LED s for progress information during use and programming and a brushed finish

More information

Provides an activation of Relay 1 triggered by Input 1. The function also provides an option for reverse-logic on the activation of Input 1.

Provides an activation of Relay 1 triggered by Input 1. The function also provides an option for reverse-logic on the activation of Input 1. USER S GUIDE PROGRAMMABLE 3-RELAY LOGIC MODULE 1 Description The is a programmable 3 relay logic module that may be used for multiple applications, including simple timing, door mounted sensor inhibiting

More information

ImproX SupaGate 4-Channel Controller INSTALLATION MANUAL

ImproX SupaGate 4-Channel Controller INSTALLATION MANUAL MODEL NUMBER: SGI911-1-1-GB-XX IMPROX SUPAGATE SPECIFICATIONS ImproX SupaGate 4-Channel Controller INSTALLATION MANUAL Working Environment... Passive Frequency... RF Frequency... Security... Input Voltage...

More information

ImproX (TRT) Twin Remote Terminal INSTALLATION MANUAL

ImproX (TRT) Twin Remote Terminal INSTALLATION MANUAL SPECIFICATIONS MODEL NUMBER: XRT910-0-0-GB-XX XRT911-0-0-GB-XX XTT911-0-0-NN-XX IMPROX TRT ImproX (TRT) Twin Remote Terminal INSTALLATION MANUAL Working Environment XRT910-0-0-GB-XX... (Aluminium Extruded

More information

LEON AUDIO. Speaker s Timer. mk3. A versatile timer for use at conferences to indicate the time remaining for a speech.

LEON AUDIO. Speaker s Timer. mk3. A versatile timer for use at conferences to indicate the time remaining for a speech. LEON AUDIO 62 Edgeware Road, Aldgate, South Australia, 5154. Phone +61 8 8339 3865 Fax +61 8 8370 8780 www.leonaudio.com.au Speaker s Timer mk3 A versatile timer for use at conferences to indicate the

More information

Enterview 2 / Enterview 2V 4 WIRE VIDEO DOORPHONE SYSTEM

Enterview 2 / Enterview 2V 4 WIRE VIDEO DOORPHONE SYSTEM Enterview / Enterview V WIRE VIDEO DOORPHONE SYSTEM INSTALLATION AND OPERATION. Introduction This Video doorphone System is an easy-to-use system offering many benefits and conveniences, such as relieving

More information

Solis Export Power Manager

Solis Export Power Manager Solis Export Power Manager Installation and Operation Manual Ningbo Ginlong Technologies Co., Ltd. No. 57 Jintong Road, Binhai Industrial Park, Xiangshan, Ningbo, Zhejiang, 3572, P.R.China Tel: +86 (0)574

More information

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N Weekly Timer 1/4 DIN Size Timer Features Prompted Programming and Large LCD Display 24 hours x 7 days programming using just 5 switches 16 program steps and cycle operation Two independent 15 A control

More information

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650 M. K. JUCHHEIM GmbH & Co Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.de

More information

VIDEO DOOR PHONE CAV-51M

VIDEO DOOR PHONE CAV-51M VIDEO DOOR PHONE CAV-51M 513-11, Sangdaewon-dong, Jungwon-gu, Seongnam-si, Gyeonggi-do, Korea Int l Business Dept. : Tel.; +82-31-7393-540~550 Fax.; +82-31-745-2133 Web site : www.commax.com Printed In

More information

Kuhnke Technical Data. Contact Details

Kuhnke Technical Data. Contact Details Kuhnke Technical Data The following page(s) are extracted from multi-page Kuhnke product catalogues or CDROMs and any page number shown is relevant to the original document. The PDF sheets here may have

More information

Figure 1: Device components

Figure 1: Device components Order No. : 2860 10 Order No. : 2830 10 Operation- and Assembly Instructions 1 Safety instructions Electrical equipment may only be installed and fitted by electrically skilled persons. Failure to observe

More information

DLP200M 2 Relay Module for Heating and Cooling Plants

DLP200M 2 Relay Module for Heating and Cooling Plants Product Sheet TH6.24 Thermostat Type DLP200M DLP200M 2 Relay Module for Heating and Cooling Plants The DLP 200 M is a relay module for activation of loads (namely thermal actuators or circulators) in wireless

More information

DLP600M 6+1 Relay Module for Heating and Cooling Plants

DLP600M 6+1 Relay Module for Heating and Cooling Plants Product Sheet TH6.25 Thermostat Type DLP600M DLP600M 6+1 Relay Module for Heating and Cooling Plants The DLP 600 M is a relay module for activation of loads (namely thermal actuators or circulators) in

More information

Installer Manual Video door entry unit with 3.5" monitor for Due Fili (Two-Wire) call system Elvox Vimar Group.

Installer Manual Video door entry unit with 3.5 monitor for Due Fili (Two-Wire) call system Elvox Vimar Group. Installer Manual 19558 Video door entry unit with 3.5" monitor for Due Fili (Two-Wire) call system Elvox Vimar Group. Table of Contents Technical characteristics 3 Type of system 3 Advantages of the Due

More information

Master Clock Controller. User Guide. pyramidtimesystems.com

Master Clock Controller. User Guide. pyramidtimesystems.com Master Clock Controller User Guide pyramidtimesystems.com TABLE OF CONTENTS TABLE OF CONTENTS... PRODUCT OVERVIEW... FEATURES... 3 CONTENTS... 4 WALL MOUNTING... 5 INSTALLATION... 6 PROGRAMMING... 7-8

More information

SU17 Series Fiber Optic Sensors

SU17 Series Fiber Optic Sensors SU17 Series Fiber Optic Sensors Fiber Optic Diffuse and Thru-Beam Mode See page 750 Sensing Range: Determined by fiber optic cable Output: NPN, PNP Built-in auto-tuning Digital display Mutual interference

More information

Model /29S RF Splitter

Model /29S RF Splitter Instruction Manual Model 1584-29/29S RF Splitter March 2013, Rev. 0 LNB VOLTAGE A B MODEL 1584 COMBINER CROSS TECHNOLOGIES INC. GND+DC ON Data, drawings, and other material contained herein are proprietary

More information

EA63-7D. Generator Automatic Voltage Regulator Operation Manual. Self Excited Automatic Voltage Regulator

EA63-7D. Generator Automatic Voltage Regulator Operation Manual. Self Excited Automatic Voltage Regulator EA63-7D Generator Automatic Voltage Regulator Operation Manual Self Excited Automatic Voltage Regulator SP POWERWORLD LTD Willows, Waterside, Ryhall, Stamford, Lincs, PE9 4EY, UK Tel: +44 1780 756872 -

More information

User Guide. Centrex Recording Interface

User Guide. Centrex Recording Interface User Guide Centrex Recording Interface Table of Contents Introduction... 2 The Meridian Business Set... 3 Key Numbering Plan (18 button add-on)... 4 Key Numbering Plan (36 button add-on)... 5 Key Numbering

More information

Sensor module. Safety instructions. Function Correct use. Product characteristics. Structure of the device. Operation. Ref.No.

Sensor module. Safety instructions. Function Correct use. Product characteristics. Structure of the device. Operation. Ref.No. Sensor module Ref.No.: SM 1608 V03 Safety instructions Caution! Electrical devices may only be installed and fitted by electrically skilled persons. Non-compliance with the installation information could

More information

4.9 BEAM BLANKING AND PULSING OPTIONS

4.9 BEAM BLANKING AND PULSING OPTIONS 4.9 BEAM BLANKING AND PULSING OPTIONS Beam Blanker BNC DESCRIPTION OF BLANKER CONTROLS Beam Blanker assembly Electron Gun Controls Blanker BNC: An input BNC on one of the 1⅓ CF flanges on the Flange Multiplexer

More information

Instruction Manual. Series 3000 Model R-165A. Audio/Video IF/RF Relay Panel. CATV Switching and Control

Instruction Manual. Series 3000 Model R-165A. Audio/Video IF/RF Relay Panel. CATV Switching and Control Series 3000 Model R-165A Audio/Video IF/RF Relay Panel Instruction Manual CATV Switching and Control 585-765-2254 fax 585-765-9330 100 Housel Ave. Lyndonville NY 14098 www.monroe-electronics.com Table

More information

SceneStyle2 User Guide

SceneStyle2 User Guide SceneStyle2 User Guide Mode Lighting (UK) Limited. The Maltings, 63 High Street, Ware, Hertfordshire, SG12 9AD, UNITED KINGDOM. Telephone: +44 (0) 1920 462121 Facsimile: +44 (0) 1920 466881 e-mail: website:

More information

Tech Support: Customer Service: General Tech Questions: Tech Docs:

Tech Support: Customer Service: General Tech Questions: Tech Docs: Tech Support: 1-800-407-4545 Customer Service: 1-800-523-2462 General Tech Questions: Tech_Services@beainc.com Tech Docs: www.beasensors.com BR3-X Programmable 3 Relay Advanced Logic Module & Restroom

More information

SINCE 1989 Quality Products, Prompt Services, Trustful Relationships www.kmindustrialcorp.com KM Industrial Corporation has established itself as a trusted supplier of Electrical, Machinery and Industry

More information

Master Clock Controller. User Guide. pyramidtimesystems.com

Master Clock Controller. User Guide. pyramidtimesystems.com Master Clock Controller User Guide pyramidtimesystems.com TABLE OF CONTENTS TABLE OF CONTENTS... PRODUCT OVERVIEW... FEATURES... 3 CONTENTS... 4 WALL MOUNTING... 5 INSTALLATION... 6 PROGRAMMING... 7-8

More information

Inductive linear position sensor LI300P0-Q25LM0-LIU5X3-H1151

Inductive linear position sensor LI300P0-Q25LM0-LIU5X3-H1151 Rectangular, aluminium / plastic Versatile mounting possibilities LED indicates measuring range Immune to electromagnetic interferences Extremely short blind zones 12 bit resolution 4-wire, 15 30 VDC Analog

More information

User Manual. Color video door phone CDV-40Q

User Manual. Color video door phone CDV-40Q User Manual Color video door phone CDV-40Q Thank Thank you you for for purchasing purchasing COMMAX COMMAX products. products. Please Please carefully carefully read read this this User s User sguide Guide(in

More information

SCALE & WEIGHT DISPLAYS

SCALE & WEIGHT DISPLAYS The MICRO SERIES SCALE & WEIGHT DISPLAYS LARGE DIGIT MODELS Mighty-5S DPM MODELS Micro-S & Mighty-1S Mighty-1S Micro-S ELECTRO-NUMERICS, INC. Introduction The Electro-Numerics family of Digital Panel Meters

More information

User Manual Color Video Door Phone

User Manual Color Video Door Phone User Manual Color Video Door Phone CMV-43A Thank you for purchasing COMMAX products. Please carefully read this User s Guide (in particular, precautions for safety) before using a product and follow instructions

More information

GS-CU001M COMMENTATOR UNIT PRODUCT DETAILS

GS-CU001M COMMENTATOR UNIT PRODUCT DETAILS GLENSOUND ELECTRONICS LTD GS-CU001M COMMENTATOR UNIT PRODUCT DETAILS 6 BROOKS PLACE, MAIDSTONE, KENT, ME1 1HE. ENGLAND. TEL: + (0) 1622 7020 Visit our Website at www.glensound.co.uk + (0) 1622 7662 FAX:

More information

Master Clock Controller. User Guide. pyramidtimesystems.com

Master Clock Controller. User Guide. pyramidtimesystems.com Master Clock Controller User Guide pyramidtimesystems.com TABLE OF CONTENTS TABLE OF CONTENTS... PRODUCT OVERVIEW... FEATURES... 3 CONTENTS... 4 WALL MOUNTING... 5 INSTALLATION... 6 PROGRAMMING... 7-8

More information

T5, T8, TC-L. PC T5 PRO lp W V 50/60/0 Hz, HO. Electronic ballasts Linear lamps T5, T8 and compact lamps TC-L

T5, T8, TC-L. PC T5 PRO lp W V 50/60/0 Hz, HO. Electronic ballasts Linear lamps T5, T8 and compact lamps TC-L T, T8, TC-L Electronic ballasts PC T PRO lp 80 W 0 0 V 0/0/0 Hz, HO L D,1 0, 1 side fixing feature side fixing feature ø,1 defined lamp warm start is 1. s constant light output independent of fluctuations

More information

Vorne Industries. 87/719 Analog Input Module User's Manual Industrial Drive Itasca, IL (630) Telefax (630)

Vorne Industries. 87/719 Analog Input Module User's Manual Industrial Drive Itasca, IL (630) Telefax (630) Vorne Industries 87/719 Analog Input Module User's Manual 1445 Industrial Drive Itasca, IL 60143-1849 (630) 875-3600 Telefax (630) 875-3609 . 3 Chapter 1 Introduction... 1.1 Accessing Wiring Connections

More information

VIDEO DOOR PHONE. Model No. APV-4PM

VIDEO DOOR PHONE. Model No. APV-4PM VIDEO DOOR PHONE Model No. APV-4PM Thank you for purchasing our COMMAX product. Please carefully read this User s Guide (in particular, precautions for safety) before using the product and follow the instructions

More information

150(5-7/8") 272.5(10-3/4") IN USE ABC DEF GHI JKL MNO PQRS TUV WXYZ. Unit center. 100(3-15/16") (Bracket-mounting pitch) 110(4-5/16") (GF-3B size)

150(5-7/8) 272.5(10-3/4) IN USE ABC DEF GHI JKL MNO PQRS TUV WXYZ. Unit center. 100(3-15/16) (Bracket-mounting pitch) 110(4-5/16) (GF-3B size) NI8 June, 2017UDATEREVI PRODUCT ESDRAWINGDGF3B) FL=1300(4'3") or 1500 TIOENTRANCE ODELNO.MOUNTING(using NGTDMBNMSTATION CRIP Unit FL=1187.5(463/4") or 1387.5(545/8") IGFIGG5561816F.NAMEPRODUCT DRAWING.NO.Unit

More information

Digital Ratio Controller

Digital Ratio Controller Digital Ratio Controller RSC-406 Control Panel USER S MANUAL RATIO CONTROLLER SPEED RUN PRG ERR RATIO % CH RSC-406 Prelude Thank you for applying our RSC-406 Ratio Controller (abb.406) to you machinery

More information

INSTRUCTIONS FOR USE Pro-Ject Tuner Box S

INSTRUCTIONS FOR USE Pro-Ject Tuner Box S INSTRUCTIONS FOR USE Pro-Ject Tuner Box S Dear music lover, thank you for purchasing a Pro-Ject Audio Systems FM-tuner. In order to achieve maximum performance and reliability you should study these instructions

More information

EA350. Generator Automatic Voltage Regulator Operation Manual

EA350. Generator Automatic Voltage Regulator Operation Manual Generator Automatic Voltage Regulator Operation Manual Self Excited Automatic Voltage Regulator For General Generators Compatible with Marathon SE350* * Use for reference purpose only and not a genuine

More information

(1) (2) (3) Bedienungs- und Montageanleitung. Safety instructions. Structure of the device

(1) (2) (3) Bedienungs- und Montageanleitung. Safety instructions. Structure of the device 3 x cinch/s-video socket Order no. 33 1532 xx USB/3.5 mm audio socket Order no. 33 1539 xx VGA socket Order no. 33 1540 xx VGA socket with screw-in lift terminals Order no. 33 1541 xx High definition socket

More information

User Manual Color video door phone

User Manual Color video door phone User Manual Color video door phone CDV-43Q Thank Thank you you for for purchasing purchasing COMMAX COMMAX products. products. Please Please carefully carefully read read this this User s User s Guide

More information

SM-10 SAT Level Meter User s Manual

SM-10 SAT Level Meter User s Manual SM-10 SAT Level Meter User s Manual DAGATRONICS CORPORATION 263-1 DUCKIDONG, ILSAN, KOYANG, KYUNGKIDO, KOREA TEL: +82-31-916-8005 FAX: +82-31-916-8080 Email: dagatron@dagatron.com Website: www.dagatron.com

More information

Fixed Audio Output for the K2 Don Wilhelm (W3FPR) & Tom Hammond (NØSS) v August 2009

Fixed Audio Output for the K2 Don Wilhelm (W3FPR) & Tom Hammond (NØSS) v August 2009 Fixed Audio Output for the K2 Don Wilhelm (W3FPR) & Tom Hammond (NØSS) v. 2.1 06 August 2009 I have had several requests to provide a fixed audio output from the K2. After looking at the circuits that

More information

LINE DRIVERS MANUAL PART NUMBER: DA3000TM0 1-IN, 1-OUT COMPOSITE VIDEO + AUDIO LINE DRIVER TABLE MOUNT USER S GUIDE

LINE DRIVERS MANUAL PART NUMBER: DA3000TM0 1-IN, 1-OUT COMPOSITE VIDEO + AUDIO LINE DRIVER TABLE MOUNT USER S GUIDE MANUAL PART NUMBER: 400-0175-001 DA3000TM0 1-IN, 1-OUT COMPOSITE VIDEO + AUDIO LINE DRIVER TABLE MOUNT USER S GUIDE TABLE OF CONTENTS Page PRECAUTIONS / SAFETY WARNINGS... 2 GENERAL... 2 INSTALLATION...

More information

ALM-6813/6812 INSTALLATION AND PROGRAMMING MANUAL

ALM-6813/6812 INSTALLATION AND PROGRAMMING MANUAL ALM-6813/6812 INSTALLATION AND PROGRAMMING MANUAL Installation and programming Manual v2.2 1 MARSS Solar Defender SYSTEM This guidebook provides the essential instructions to install and configure the

More information

Telemetry Receiver Installation Guide

Telemetry Receiver Installation Guide BBV Telemetry Receiver Installation Guide Models covered Rx400P Building Block Video Ltd., Unit 1, Avocet Way, Diplocks Industrial Estate, Hailsham, East Sussex, UK. Tel: +44 (0)1323 842727 Fax: +44 (0)1323

More information

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area Guide for installers METTLER TOLEDO MultiRange System solution analog Ex1 Hazardous area Safe area System solution analog Ex1 Contents Contents Page 1 Safety precautions... 2 2 System overview... 3 2.1

More information

SPECIFICATION NO Model 207 Automatic GTAW Welding System

SPECIFICATION NO Model 207 Automatic GTAW Welding System 1.0 Introduction The Model 207 is a completely self-contained Gas Tungsten Arc Welding (GTAW) System requiring only input power, inert gas and AMI Welding Head (or manual torch) for operation. Its small

More information

FlexiScan. Impro FlexiScan 4-Channel Controller INSTALLATION MANUAL

FlexiScan. Impro FlexiScan 4-Channel Controller INSTALLATION MANUAL MODEL NUMBER: HCM991-0-0-GB-XX FlexiScan SPECIFICATIONS Impro FlexiScan 4-Channel Controller INSTALLATION MANUAL Working Environment... Security... Input Voltage... The Impro FlexiScan is designed to work

More information

Output Board - v2* 4.1 Overview. 4.2 Audio Circuitry Program and Audition Outputs

Output Board - v2* 4.1 Overview. 4.2 Audio Circuitry Program and Audition Outputs Output Board - v2* 4.1 Overview This circuit board provides the following console functions: Line output amplification Cue amplification Headphone amplification External Inputs (balanced *) Monitor sends

More information

POINTS POSITION INDICATOR PPI4

POINTS POSITION INDICATOR PPI4 POINTS POSITION INDICATOR PPI4 Monitors the brief positive operating voltage across points motors when they are switched Lights a corresponding led on a control panel to show the last operation of each

More information

Site Installation Model MP-8433

Site Installation Model MP-8433 Site Installation Model MP- Rev. //0 SCOREBOARD SITE INSTALLATION INSTRUCTIONS CAUTION: All American Scoreboards (AAS) recommends the sign be installed by a licensed contractor, and must meet all local

More information

System 2000 System 2000 HLK relay insert. 1 Safety instructions. 2 Device components. 3 Function. Order No. : Operating instructions

System 2000 System 2000 HLK relay insert. 1 Safety instructions. 2 Device components. 3 Function. Order No. : Operating instructions Order No. : 0303 00 Operating instructions 1 Safety instructions Electrical equipment may only be installed and fitted by electrically skilled persons. Failure to observe the instructions may cause damage

More information

Site Installation Model MP-8424

Site Installation Model MP-8424 Site Installation Model MP- Rev. //0 SCOREBOARD SITE INSTALLATION INSTRUCTIONS CAUTION: All American Scoreboards (AAS) recommends the sign be installed by a licensed contractor, and must meet all local

More information

PREPAX DELUXE INTERCOM SYSTEMS

PREPAX DELUXE INTERCOM SYSTEMS PREPAX DELUXE INTERCOM SYSTEMS Thank you for investing in a PREPAX Deluxe model intercom system. Kindly make sure that the input voltage specifications are maintained and that no external voltage is applied

More information

XTM72 Exerciser Timer Module

XTM72 Exerciser Timer Module Capricorn Controls DA01XTM1-1 Data & Application Note Page 1 of 6 XTM72 Exerciser Timer Module Genset Controls - Timers - Monitors - Trips - Battery Charging - Spares & Accessories - Custom Products This

More information

epos & Security Essentials Trade ONLY ONLY Trade Catalogue Call us Now on Visit Our Website

epos & Security Essentials Trade ONLY ONLY Trade Catalogue Call us Now on Visit Our Website epos & Security Essentials Trade Catalogue Trade ONLY ONLY Call us Now on 024 7668 8590 Visit Our Website www.tronicextreme.co.uk 2 Item No. 10595 Item No. 10596 TP-101 All in One Touch Screen epos System

More information

Operating Instructions

Operating Instructions COUNTERS CONTROLLERS ENCODERS Operating Instructions Electronic Preselection Counter Two preselections NE 216 Contents Page 1 Safety indications... 2 2 Get to know your NE 216... 4 2.1 NE216 components...

More information

Multi-functional safety relay modules PROTECT SRB-E

Multi-functional safety relay modules PROTECT SRB-E Multi-functional safety relay modules PROTECT SRB-E PROTECT SRB-E The configurable User-friendly Up to 16 different applications can be selected Monitoring of all conventional safety switchgear Safety

More information

Intelligent Security and Fire Ltd

Intelligent Security and Fire Ltd User Manual Product ranges covered by this manual Vi-P14 Vi-P14A Document Reference Date Firmware Vi-Q4C1 Viq601a.doc 26/11/2009 From Viq001a21 Videoswitch Telephone 01252-851510 Ocean House, Redfields

More information

Solid-State Digital Timer

Solid-State Digital Timer Solid-State Digital Timer 1/16 DIN, Digital-Set Timer with 0.1 Second to 9,990 Hours Range 8 field-selectable operation modes Universal AC/DC supply voltage timers available Operations include ON-delay,

More information

For applications from 0.25 to 5 HP, the MD60 is a simple AC Microdrive that can be panel mounted as well as wall or machine mounted.

For applications from 0.25 to 5 HP, the MD60 is a simple AC Microdrive that can be panel mounted as well as wall or machine mounted. For applications from 0.25 to 5 HP, the MD60 is a simple AC Microdrive that can be panel mounted as well as wall or machine mounted. N223 Reliance Electric s MD60 AC Drive is ready to operate out-of-the-box!

More information

Miniguard HF-2 with Prox Reader or TELEPROX

Miniguard HF-2 with Prox Reader or TELEPROX Miniguard HF-2 with Prox Reader or TELEPROX Handsfree Telephone Entry Autodialer INSTALLATION and OPERATIONAL INSTRUCTIONS 255 Glider Circle Corona, CA 92880 (951) 371-1730 Facsimile (951) 371-2592 www.trigonelectronics.com

More information

Operating instructions Retro-reflective sensor. OJ50xx laser / / 2010

Operating instructions Retro-reflective sensor. OJ50xx laser / / 2010 Operating instructions Retro-reflective sensor OJ50xx laser 70481 / 00 05 / 010 Contents 1 Preliminary note3 1.1 Symbols used 3 Safety instructions 3 4 Installation 4 4.1 Installation of the supplied mounting

More information

Weekly Time Switch. Rated time Time setting range Time division 24 hrs x 7 days 00:00 to 23:59 1min

Weekly Time Switch. Rated time Time setting range Time division 24 hrs x 7 days 00:00 to 23:59 1min Weekly Time Switch Easy Programming with Large LCD Display and Interactive Functions Programming for 24 hrs x 7 days using just five switches. Sixteen program steps available. Power supply freely selectable

More information

PicoBoo PLUS. OPERATING MANUAL V1.1 (Sep 8, 2011) 6 Oakside Court Barrie, Ontario L4N 5V5 Tel: or

PicoBoo PLUS. OPERATING MANUAL V1.1 (Sep 8, 2011) 6 Oakside Court Barrie, Ontario L4N 5V5 Tel: or PicoBoo PLUS OPERATING MANUAL V1.1 (Sep 8, 2011) 6 Oakside Court Barrie, Ontario L4N 5V5 Tel: 1-877-815-5744 or 905-803-9274 www.frightideas.com Getting familiar with your PicoBoo PLUS Powering Up Sizing

More information

RD RACK MOUNT DIMMER OWNERS MANUAL VERSION /09/2011

RD RACK MOUNT DIMMER OWNERS MANUAL VERSION /09/2011 RD - 122 RACK MOUNT DIMMER OWNERS MANUAL VERSION 1.3 03/09/2011 Page 2 of 14 TABLE OF CONTENTS UNIT DESCRIPTION AND FUNCTIONS 3 POWER REQUIREMENTS 3 INSTALLATION 3 PLACEMENT 3 POWER CONNECTIONS 3 OUTPUT

More information

TECHNOLOGY USER MANUAL. Audio and Video Door Entry System Nexa Modular Gb2 2-Wire

TECHNOLOGY USER MANUAL. Audio and Video Door Entry System Nexa Modular Gb2 2-Wire TEHNOOGY USER MANUA Audio and Video Door Entry System Nexa Modular Gb2 2-Wire AWD267 Rev. 08/2018 2 TENTS Introduction......2 ontents.....2. Set-up warnings......2. Safety precautions...... 3 haracteristics...3

More information

2 Hour Electronic Boost Timer

2 Hour Electronic Boost Timer 2 Hour Electronic Boost Timer Model No. TGBT4 Installation & Operating Instructions 1. General Information These instructions should be read carefully and retained for further reference and maintenance.

More information

Self Excited Automatic Voltage Regulator For Generator Compatible with Marathon SE350* Operation Manual

Self Excited Automatic Voltage Regulator For Generator Compatible with Marathon SE350* Operation Manual Self Excited Automatic Voltage Regulator For Generator Compatible with Marathon SE350* Operation Manual s * Use for reference purpose only and not a genuine Marathon product. 1. INTRODUCTION Sensing Input

More information

BooBox Flex. OPERATING MANUAL V1.1 (Feb 24, 2010) 6 Oakside Court Barrie, Ontario L4N 5V5 Tel: Fax:

BooBox Flex. OPERATING MANUAL V1.1 (Feb 24, 2010) 6 Oakside Court Barrie, Ontario L4N 5V5 Tel: Fax: BooBox Flex OPERATING MANUAL V1.1 (Feb 24, 2010) 6 Oakside Court Barrie, Ontario L4N 5V5 Tel: 905-803-9274 Fax: 647-439-1470 www.frightideas.com Connections The BooBox Flex is available with Terminal Blocks

More information

Sentinel I24 Digital Input and Output Configuration

Sentinel I24 Digital Input and Output Configuration Application Bulletin: #155 Date: October 19, 2007 Sentinel I24 Digital Input and Output Configuration The Sentinel I24 can communicate with external hardware using digital inputs and outputs. There are

More information