INVERTERS UPS FREQUENCY CONVERTERS. Land Sea Air MILITARY COMMERCIAL INDUSTRIAL AS Certificate No: US

Size: px
Start display at page:

Download "INVERTERS UPS FREQUENCY CONVERTERS. Land Sea Air MILITARY COMMERCIAL INDUSTRIAL AS Certificate No: US"

Transcription

1 INVERTERS UPS FREQUENCY CONVERTERS Land Sea Air MILITARY COMMERCIAL INDUSTRIAL

2 TABLE OF CONTENTS ABOUT US Technological leader in power conversion technology Pgs. I-III UNINTERRUPTIBLE POWER SUPPLIES Full array of rugged true online UPS systems Pgs INVERTERS Full array of rugged pure sinewave DC-AC inverter systems Pgs FREQUENCY CONVERTERS Full array of rugged solid state frequency converter systems Pgs POWER ACCESSORIES Full Array of Rugged Portable Transformers Custom EMI Filters External Bypass Switches Power Distribution Units Pg. 108 QUALITY ASSURANCE Reliability Quality Rugged Design Pg. IV OTHER DIVISIONS Technology Dynamics Inc divisions at a glance Pg. V For more information, please visit us at or us at novasales@theallpower.com

3 ABOUT US COMPANY PROFILE & FACILITIES I Technology Dynamics Inc. (TDI) is has been America s premier supplier of rugged MIL-Spec AC and DC Power Solutions since The company structure encompasses multiple divisions, each dedicated to a specific niche within the power conversion and electronic packaging sectors, as follows: TECHNOLOGY DYNAMICS, INC. The All Power Company Bergenfield, NJ TECHNOLOGY DYNAMICS, INC. Bergenfield, NJ Switching Power Supplies DC-DC Converters DC-UPS Battery Backup NOVA ELECTRIC Bergenfield, NJ Rugged Transformers Custom EMI Filters Bypass Switches Pure Sinewave DC-AC Inverters True Online UPS Frequency Converters ELECTRONICS INTEGRATION TECHNOLOGY, INC. Eatontown, NJ Contract Manufacturing Build-to-Print PCB Assembly & Services NOVA INTEGRATION SOLUTIONS Saint Cloud, FL Rugged & Mil-Spec Printers Rackmount & Custom Chassis ATR Chassis & Backplanes NOVA BATTERY SYSTEMS Bergenfield, NJ Custom Battery Packs Custom Battery Chargers Battery Research & Testing MID-EASTERN INDUSTRIES Bergenfield, NJ Linear Power Supplies Towed Array Power Supplies Control Power Systems Bergenfield, NJ Bergenfield, NJ Eatontown, NJ Bergenfield, NJ Bergenfield, NJ St Cloud, FL NOVA ELECTRIC BERGENFIELD, NJ ELECTRONIC INTEGRATION TECHNOLOGY INC. EATON TOWN, NJ NOVA BATTERY SYSTEMS BERGENFIELD, NJ FACILITIES Nova Electric Div. resides within a 50,000 square foot factory complex in Bergenfield, NJ USA, approximately 20 minutes from New York City. This plant includes all necessary facilities for the complete design, manufacturing, and testing of True Online UPS Systems, Pure Sinewave DC-AC Inverters, Solid State Frequency Converters, Power Distribution Units, EMI Filters, Maintenance Bypass Switches, Power Supplies, and related accessories. Having all facets of the design and production of our products under one roof ensures total quality, quick delivery, and gives Nova Electric the ability to rapidly customize COTS equipment as required. IN HOUSE CAPABILITIES Electrical and mechanical engineering Sheet metal fabrication Transformer parts manufacture and assembly PC board assembly Final box assembly Test facilities including vibration and temperature Research and Development Continuous technology development Product assembly Full battery electrical testing Software simulation tools NOVA ELECTRIC Leader in power conversion technology since 1966 MADE IN USA

4 II ABOUT US DESIGN CAPABILITIES Nova Electric s product mix consists primarily of Pure Sine Wave DC-AC Inverters, True On-Line UPS Systems, and Solid-State Frequency Converters. These AC Sources are normally sold off the shelf or ruggedized to satisfy harsh environment military applications. Military-grade models as shown are fully qualified to many standards such as MIL-STD-1399, MIL-STD-461, MIL-S-901, MIL-STD-810, MIL-STD-167, MIL-STD-740, DOD-STD-1399, MIL-STD-1275, and many others. In addition, most of Nova s standard products can be modified or customized to meet specific requirements. The Pure Sine Wave DC-AC Inverters span the 100W to 200+ KW power levels, in most standard nominal DC inputs including 12, 24, 36, 48, 72, 120, 155, 240, 350, 600, and 750 VDC. AC Outputs offered include any standard single phase voltage (120 or 220 VAC) or three-phase voltage (120/208, 220/380, or 277/480 VAC), in 50 Hz, 60 Hz, or 400 Hz versions. Our inverters are offered in freestanding, rack-mount, and NEMA cabinet configurations as required, though the standard enclosures are as shown VDC NOMINAL 120VAC OR 220VAC 1 PHASE 50 Hz, 60 Hz or 400 Hz The True On-Line UPS Systems are offered in 1 KVA to 450+ KVA power levels, in any standard single phase voltage (120 or 220 VAC) or three-phase voltage (120/208, 220/380, or 277/480 VAC), in 50 Hz, 60 Hz, or 400 Hz versions. Most of our UPS Systems can also function as voltage / frequency converters, with the ability to convert a given single or three phase AC input to another single or three phase AC output, in conjunction with the usual battery backup capabilities. Many models also offer an Auto-Select input function, which allows the UPS to operate automatically on either a 120 or 220 VAC, 50, 60, or 400 Hz input voltage. Our UPS Systems are offered in freestanding, rack-mount, and NEMA cabinet configurations as required, though the standard enclosures are as shown. 120/208 VAC 60 Hz 3 Phase ETL CERTIFIED TO UL 1778 For more information, please visit us at or us at novasales@theallpower.com

5 III The Solid-State Frequency Converters are available in 120 VA to 450+ KVA power levels, and can convert any standard single phase voltage (120 or 220 VAC) or three-phase voltage (120/208, 220/380, or 277/480 VAC) to another. Every model is available in 50 Hz, 60 Hz, or 400 Hz input or output. Alternative frequencies (such as 100 Hz for special railroad applications) are available upon request. All of these converters boast the superior reliability, reduced maintenance costs and noise levels, and more compact, lightweight dimensions that can only be achieved utilizing a modern solid-state design. These converters are offered in freestanding, rack-mount, and NEMA cabinet configurations as required, though the standard enclosures are as shown. SINGLE PHASE 120 VA KVA COMPACT 1U-4U CHASSIS 700W - 4KW POWER UNIVERSAL 120/240 VAC PFC INPUT Hz OPTIONAL SNMP COMMUNICATIONS Many of Nova Electric s models feature sophisticated PWM technology, microprocessor control, comprehensive display panels, as well as SNMP / Ethernet, RS-232, and RS-485 communications capabilities. All can be ruggedized against shock, vibration, and humidity to meet MIL-STD-810. These power sources are offered in a wide variety of standard rugged and COTS configurations, which can also be quickly customized per each customer s unique application. However, for a majority of applications, the products shown do not require any modification or customization. GREEN INITIATIVES We applaud the US Armed Forces for their initiatives to reduce our dependence on fossil fuels. We strive to make our products smaller, lighter, and more efficient in keeping with US Armed Forces desire to reduce carbon footprints at installations worldwide. As a result, end users can expect: Smaller physical footprints for higher space efficiency Lighter Weight for less energy expended on mobile applications Higher Efficiency for less wasted power loss during usage In addition, products are manufactured using renewable energy sources, including the company s 175 KW Rooftop Solar Array for Electrical power used in manufacturing. NOVA ELECTRIC Leader in power conversion technology since 1966 MADE IN USA

6 1 ULTRA-LIGHTWEIGHT RUGGED GALAXY SERIES UPS F COMPACT CHASSIS (1U - 5U TALL) MIL-SPEC COMPLIANT 1-5 KVA F BULKHEAD MOUNTING AVAILABLE F ULTRA LIGHTWEIGHT DESIGN F POWER FACTOR CORRECTED UNIVERSAL INPUT F FULL COMPLIANCE TO MIL-SPECS F SNMP COMMUNICATIONS F LITHIUM PHOSPHATE BATTERIES AVAILABLE UNIVERSAL 120/240 VAC PFC INPUT SNMP COMMUNICATIONS WHEN EVERY POUND COUNTS! APPLICATIONS Shipboard Shelters Tactical Systems Aircraft HMMWVs Mobile Systems Ground Support Transit Cases COMPLIANCE MIL-STD-1399 MIL-STD-810 MIL-S-901 MIL-STD-167 MIL-STD-461 MIL-STD-704 DOD-STD-1399 For more information, please visit us at or us at novasales@theallpower.com

7 Uninterruptible Power Supply for Naval Ground Airborne Applications WHEN EVERY POUND COUNTS! Nova s Ultra Lightweight Galaxy-Series UPS Systems are highreliability power sources specifically designed for demanding applications in high shock, vibration, humidity, and EMI environments in compliance to MIL-STD-1399, MIL-STD-461, MIL-S-901, MIL-STD-167, MIL-STD-810, MIL-STD-740, and DOD-STD These models utilize True On-Line technology, offering maximum field-proven reliability for severe environment and high reliability applications such as: 1U Rack Mount 2 r MILITARY APPLICATIONS HMMWV UAV Shipboard Submarine Aircraft Mobile Power Units Shelters Transportable Systems Tactical Systems Ground Support 2U Rack Mount 3U Rack Mount r r r HEAVY-DUTY INDUSTRIAL APPLICATIONS DEMANDING COMMERCIAL APPLICATIONS COMMUNICATIONS SYSTEMS 4U Rack Mount Bulkhead Mounting 5U Rack Mount NOVA ELECTRIC Leader in power conversion technology since 1966 MADE IN USA

8 3 Uninterruptible Power Supply for Naval Ground Airborne Applications PROTECTIVE FEATURES AC & DC Input Circuit Breakers Low Battery Automatic Overload & Short Citcuit Protection Shut Off with Circuit Breaker Thermal Protected Input Under/Overvoltage Protected Audible Alarm with Silence Switch ENVIRONMENTAL UPS Operating Temp.: -20 to +55 C (Extended ranges optional) UPS Storage temperature range: -40 to +71 C (Electronics Only - Extended ranges optional) Humidity: to 95% RH non-condensing All boards conformal coated with Acrylic MIL-I Type R. Elevation: 15,000 Ft. (4,572 m) operating; 40,000 Ft. (12,192 m) non-operating (Higher Optional) Shock: 20 g, 11 ms half sinewave Audible Noise: Less than 55 dba at 5 ft. MTBF: 100,000+ hours per field +25C Ambient Ground-Fixed MTTR: 30 minutes by qualified personnel INDICATORS Status (Red / Green) UPS Off (Red) UPS Off (Red) Logic Fault (Red) Low Battery (Red) Over Temperature (Red) Load on Utility (Red) with optional transfer switch AUDIBLE Audible alarm with silence swich. COMMUNICATIONS SNMP V1.0 standard via CAT-5 Connector (V3.0 Optional) RS 232 (Available-Optional) Via DB 9 Connector Alarm Contacts (Available-Optional) Major Alarm: Logic Fault, Low Battery, OT, UPS Overloaded Minor Alarm: Utility Off, Load on Utility (With optional transfer switch) For more information, please visit us at or us at novasales@theallpower.com

9 Uninterruptible Power Supply for Naval Ground Airborne Applications 4 AVAILABLE OPTIONS Power distribution units MS connector mates and multiple output outlets Chassis Slide Guides Internal transfer switch (static or electromechanical) Custom Enclosures Additional run time via external batteries 3Ø Power Input Premium VRLA batteries with up to 10 year life 400 Hz input and / or output LiFe models feature internal Lithium Iron Phosphate batteries for substantial weight savings and longer runtime, including embedded Battery Management System CAD Free Connectors Non-PVC wiring 28 VDC Input High IP Protection for front / rear panels AUX DC Outputs RTCA/DO-160G Compliant Aircraft Grade Package Typical IP32 Protection Package ELECTRICAL Input Voltage: Output Voltage: Frequency: SPECIFICATIONS Voltage Regulation: 120/240 VAC ( VAC) PFC (3Ø input optional) 120, 208, or 230 VAC (specify) 50 / 60 / 400 Hz. Available ± 2% NL to FL Frequency Regulation: ± 0.5% NL to FL Harmonic Distortion: Input Power Factor: Efficiency at full load: Connections: 5% THD, 3% typical 0.95 or half-full load full load typical (batteries charged) MS Connector (mates optional) Overload: 110% load for 10 minutes 115% load for 5 minutes 120% load for 2 minutes NOMINAL DIMENSIONS: UPS Dimensions: 19 Wide x 24 Deep (See chart for height) Note: External batteries available on all models if increased run time is required up to 24 hours. External battery drawer typically 2-4U depending on requirements. BATTERIES Internal on all but 5KVA EXT models Standard sealed, maintenance free lead acid batteries have -20 C to +50 C storage range. Optional Premium sealed, maintenance free lead acid batteries have -40 C to +80 C operating range and useful life of C ambient. Optional Lithium Iron Phosphate batteries (as shown in units with LiFe model suffix) have -20 C to +60 C operating range and useful life of C ambient, but are much lighter than lead acid batteries and offer about twice the battery run time in the same volume battery pack. NOVA ELECTRIC Leader in power conversion technology since 1966 MADE IN USA

10 5 Uninterruptible Power Supply for Naval Ground Airborne Applications 120 VAC RACK MOUNT MODELS (400Hz Input and/or Output optional on all models) MODEL KVA KW NOMINAL INPUT INPUT AMPS UPS LBS. RUNTIME GRSLPFC11-5K60-120/240A-120-5M-5U VAC 26A KW 5U GRSLPFC11-5K60-120/240A-120-5M-5U-LIFE VAC 26A KW 5U GRSLPFC11-5K60-120/240A-120-4U VAC 26A 45 External 4U GRSLPFC11-3K60-120/240A-120-5M-4U VAC 26A 95 5 min. 4U GRSLPFC11-3K60-120/240A-120-5M-4U-LIFE VAC 24/12A 70 5 min. 4U GRSLPFC11-3K60-120/240A M-4U VAC 24/12A 95 7 min. 4U GRSLPFC11-3K60-120/240A-120-5M-3U VAC 24/12A 80 5 min. 3U GRSLPFC11-3K60-120/240A-120-5M-3U-LIFE VAC 24/12A 65 5 min. 3U GRSLPFC11-2K60-120/ M-3U VAC 16/8A 80 7 min. 3U GRSLPFC11-2K60-120/ M-3U-LIFE VAC 16/8A 65 7 min. 3U GRSLPFC11-1.5K60-120/240A M-2U VAC 12/6A 60 5 min. 2U GRSLPFC11-1.5K60-120/240A M-2U-LIFE VAC 12/6A min. 2U GRSLPFC11-1K60-120/240A M-1U-LIFE VAC 8/4A min. 1U 230 VAC RACK MOUNT MODELS (400Hz Input and/or Output optional on all models) MODEL KVA KW NOMINAL INPUT INPUT AMPS UPS LBS. RUNTIME GRSLPFC11-5K50-120/240A-230-5M-5U VAC 26A KW 5U GRSLPFC11-5K60-120/240A-230-5M-5U-LIFE VAC 26A KW 5U GRSLPFC11-5K50-120/240A-230-5M-4U VAC 26A 45 External 4U GRSLPFC11-3K50-120/240A-230-5M-4U VAC 30/15A 95 5 min. 4U GRSLPFC11-3K60-120/240A-230-5M-4U-LIFE VAC 30/15A 70 5 min. 4U GRSLPFC11-3K50-120/240A M-4U VAC 24/12A 95 7 min. 4U GRSLPFC11-3K50-120/240A M-3U VAC 24/12A 80 5 min. 3U GRSLPFC11-3K60-120/240A-230-5M-3U-LIFE VAC 24/12A 65 5 min. 3U GRSLPFC11-2K50-120/240A M-3U VAC 16/8A 80 7 min. 3U GRSLPFC11-2K50-120/240A M-3U-LIFE VAC 16/8A 65 7 min. 3U GRSLPFC11-1.5K50-120/240A M-2U VAC 12/6A 60 5 min. 2U GRSLPFC11-1.5K50-120/240A M-2U-LIFE VAC 12/6A min. 2U GRSLPFC11-1K50-120/240A M-1U-LIFE VAC 8/4A min. 1U 3Ø INPUT RACK MOUNT MODELS (400Hz Input and/or Output optional on all models) MODEL KVA KW NOMINAL INPUT INPUT AMPS UPS LBS. RUNTIME GRSLPFC11-5K60-120/ M-5U /208 VAC 3Ø 15A KW 5U GRSLPFC11-5K60-120/208-5M-5U-LIFE /208 VAC 3Ø 15A KW 5U GRSLPFC11-3K60-120/ M-4U /208 VAC 3Ø 11A 95 5 min. 4U GRSLPFC11-3K60-120/ M-4U-LIFE /208 VAC 3Ø 9A 70 5 min. 4U GRSLPFC11-3K60-120/ M-4U /208 VAC 3Ø 9A 95 7 min. 4U GRSLPFC11-3K60-120/ M-3U /208 VAC 3Ø 9A 80 5 min. 3U GRSLPFC11-3K60-120/ M-3U-LIFE /208 VAC 3Ø 9A 65 5 min. 3U GRSLPFC11-2K60-120/ M-3U /208 VAC 3Ø 6A 80 7 min. 3U GRSLPFC11-2K60-120/ M-3U-LIFE /208 VAC 3Ø 6A 65 7 min. 3U GRSLPFC11-1.5K60-120/ M-2U /208 VAC 3Ø 5A 60 5 min. 2U GRSLPFC11-1.5K60-120/ M-2U-LIFE /208 VAC 3Ø 5A min. 2U HEIGHT HEIGHT HEIGHT For more information, please visit us at or us at novasales@theallpower.com

11 Uninterruptible Power Supply for Naval Ground Airborne Applications 120 VAC BULKHEAD MOUNTING MODELS (400Hz Input and/or Output optional on all models) MODEL KVA KW NOMINAL INPUT INPUT AMPS UPS LBS. RUNTIME (MINUTES) DIMENSIONS GHSLPFC11-5K60-120/240A-120-5M VAC 52/26A x 24 x 16 GHSLPFC11-5K60-120/240A M-LIFE VAC 52/26A x 24 x 16 GHSLPFC11-3K60-120/240A-120-5M VAC 30/15A x 24 x 16 GHSLPFC11-3K60-120/240A-120-5M-LIFE VAC 30/15A x 24 x 16 GHSLPFC11-3K60-120/240A-120-7M VAC 24/12A x 24 x 16 GHSLPFC11-3K60-120/240A M-LIFE VAC 24/12A x 24 x 16 GHSLPFC11-2K60-120/ M VAC 16/8A x 24 x 16 GHSLPFC11-2K60-120/ M-LIFE VAC 16/8A x 24 x 16 GHSLPFC11-1.5K60-120/240A-120-5M VAC 12/6A x 24 x 16 GHSLPFC11-1.5K60-120/240A M-LIFE VAC 12/6A x 24 x 16 GHSLPFC11-1K60-120/240A VAC 8/4A x 24 x 16 GHSLPFC11-1K60-120/240A-120-LIFE VAC 8/4A x 24 x VAC BULKHEAD MOUNTING MODELS (400Hz Input and/or Output optional on all models) MODEL KVA KW NOMINAL INPUT INPUT AMPS UPS LBS. RUNTIME (MINUTES) DIMENSIONS GHSLPFC11-5K50-120/240A-230-5M VAC 52/26A x 24 x 16 GHSLPFC11-5K50-120/240A M-LIFE VAC 52/26A x 24 x 16 GHSLPFC11-3K50-120/240A-230-5M VAC 30/15A x 24 x 16 GHSLPFC11-3K50-120/240A-230-5M-LIFE VAC 30/15A x 24 x 16 GHSLPFC11-3K50-120/240A-230-7M VAC 24/12A x 24 x 16 GHSLPFC11-3K50-120/240A M-LIFE VAC 24/12A x 24 x 16 GHSLPFC11-2K50-120/ M VAC 16/8A x 24 x 16 GRHSLPFC11-2K50-120/ M-LIFE VAC 16/8A x 24 x 16 GHSLPFC11-1.5K50-120/240A-230-5M VAC 12/6A x 24 x 16 GHSLPFC11-1.5K50-120/240A M-LIFE VAC 12/6A x 24 x 16 GHSLPFC11-1K50-120/240A VAC 8/4A x 24 x 16 GHSLPFC11-1K50-120/240A-230-LIFE VAC 8/4A x 24 x 16 3Ø INPUT BULKHEAD MOUNTING MODELS (400Hz Input and/or Output optional on all models) MODEL KVA KW NOMINAL INPUT INPUT AMPS UPS LBS. RUNTIME (MINUTES) DIMENSIONS GHSLPFC11-5K60-120/ M-5U /208 VAC 3Ø 15A x 24 x 16 GHSLPFC11-5K60-120/ M-LIFE /208 VAC 3Ø 15A x 24 x 16 GHSLPFC11-3K60-120/ M /208 VAC 3Ø 11A x 24 x 16 GHSLPFC11-3K60-120/ M-LIFE /208 VAC 3Ø 11A x 24 x 16 GHSLPFC11-3K60-120/ M /208 VAC 3Ø 9A x 24 x 16 GHSLPFC11-3K60-120/ M-LIFE /208 VAC 3Ø 9A x 24 x 16 GHSLPFC11-2K60-120/ M /208 VAC 3Ø 6A x 24 x 16 GHSLPFC11-2K60-120/ M-LIFE /208 VAC 3Ø 6A x 24 x 16 GHSLPFC11-1.5K60-120/ M /208 VAC 3Ø 5A x 24 x 16 GHSLPFC11-1.5K60-120/ M-LIFE /208 VAC 3Ø 5A x 24 x 16 GHSLPFC11-1K60-120/ /208 VAC 3Ø 2A x 24 x 16 GHSLPFC11-1K60-120/ LIFE /208 VAC 3Ø 2A x 24 x 16 6 NOVA ELECTRIC Leader in power conversion technology since 1966 MADE IN USA

12 7 Uninterruptible Power Supply for Naval Ground Airborne Applications SYSTEM COMPLIANCE MIL-STD-1399 Section 300B: For Type I apparatus MIL-STD-740-1: Airborne Sound Measurements for Shipboard Equipment MIL-STD-740-2: Structureborne Vibratory Acceleration Measurements Additional Ruggedization to meet MIL-S-901, MIL-STD-167, MIL-STD-810, and DOD-STD-1399: The UPS System s construcon is extremely robust, and ruggedized throughout. All components and modules within the unit are mounted using additional steel brackets and heavy-duty stainless-steel hardware, which is then further secured using Loctite and RTV where required. All boards are conformal-coated (Acrylic MIL-I Type R) for maximum resistance to potential condensation and fungus growth. The unit was tested and qualified as follows: MIL-S-901D for Grade A, Class II, Type B Equipment mounted in shock-isolated rack attenuating to 20g/11ms max Bulkhead Mount UPS are 901D compliant with optional shock mounts MIL-STD for Type I Equipment MIL-STD-810 Air Temperature per MIL-STD-810F Method 502.4, Procedure II Steady State Temperature per MIL-STD-810F, Method 501.4, Procedure I (Constant Temperature) and Method 502.4, Procedure I Temperature Shock per MIL-STD-810F, Method 503.4, Procedure II, Cyclic Thermal Shock testing per MIL-STD-810G, Method 503.5, Procedure I-D Operating Temperature Shock per MIL-STD-810B Method to 71 C High Temperature Storage per MIL-STD-810G, Method 501.5, Procedure I Low Temperature Storage testing per MIL-STD-810G, Method 502.5, Procedure I Operational Humidity per MIL-STD-810F Method Humidity per MIL-STD-801G, Method 507.5, Procedure I Storage and Transportation Humidity per MIL-STD-810F, Method Salt Fog Atmosphere per MIL-STD-810F Method Altitude per MIL-STD-810F, Method 500.4, Procedure I, Storage/Air Transport Operating and Non-Operating Altitude Testing per MIL-STD-810G, Method 500.5, Procedure II Rapid Decompression per MIL-STD-810F, Method 500.4, Procedure III Transit Shock per MIL-STD-810F, Method 516, Procedures IV, V and VI Transportation Vibration per MIL-STD-810F, Method 514.5, Procedure II for loose cargo transportation Transportation Vibration per MIL-STD-810G, Method 514-6, Procedure I, Category 20 Vibration per MIL-STD-810B Method 514.6, Category 12, Procedure I Transit Drop per MIL-STD-810F, Method 516.5, Procedure IV Transit Drop per MIL-STD-810G, Method 516.6, Procedure IV Bench Handling per MIL-STD-810F, Method 516.5, Procedure VI Bench Handling per MIL-STD-810G, Method 516.6, Procedure VI DOD-STD-1399 Section 301A Table V Design Limits for Ship Motion Internal EMI Reduction Package to meet MIL-STD-461: The design of this unit is specifically focused on reducing EMI emissions. The UPS contains substantial internal filtering to minimize EMI emissions. Inputs which may be susceptible to transients are protected by several methods. The compact rack mount chassis is specifically treated with low surface resistivity finishes on the interior. All aluminum parts are treated with clear irridite. The steel parts are treated with zinc plate, followed by a clear chromate. Paint method via ANSI-61 gray is designed to assure excellent bonding of mating sheet metal parts. All input and output ventilation filters include metal honeycomb-style or mesh filters. The unit was tested and qualified as follows: MIL-STD-461E: CE101, CE102, CS101, CS114, CS116, RE102, RS101, and RS103 OPTIONAL COMPLIANCE WITH RCTA/DO-160G AIRCRAFT GRADE PACKAGE Qualifications to RTCA/DO-160G include: Rapid Decompression: Section 4 Cabin Pressure (8K) to Max Oper Alt (35K) in 15 sec; Hold for 10 min Crash Safety Sustained: Section 7, Cat B - Up = 3.0g - Down = 6.0g - Fwd = 9.0g - Aft = 1.5g - Side =4.0g Explosive Atmosphere: Non-Ignition Test Sec , Cat E Qualifications to MIL-STD-810B include: Operating Temperature Shock per MIL-STD-810B Method to 71 C Vibration per MIL-STD-810B Method 514.6, Category 12, Procedure I Note: Qualification testing was performed with optional premium batteries required to meet temperature testing requirements. For more information, please visit us at or us at novasales@theallpower.com

13 Uninterruptible Power Supply for Naval Ground Airborne Applications 8 TYPICAL KW BULKHEAD CABINET NOVA ELECTRIC Leader in power conversion technology since 1966 MADE IN USA

14 9 Uninterruptible Power Supply for Naval Ground Airborne Applications Notes: 1. MS Connectors with mates optional 2. Chassis slides optional TYPICAL 1U CHASSIS EST. WEIGHT 60 LBS. VRLA BATTERIES 37 LBS. LIFE BATTERIES TYPICAL 2U CHASSIS For more information, please visit us at or us at

15 Uninterruptible Power Supply for Naval Ground Airborne Applications 10 TYPICAL 3U CHASSIS NOVA ELECTRIC Leader in power conversion technology since 1966 MADE IN USA

16 11 Uninterruptible Power Supply for Naval Ground Airborne Applications TYPICAL 4U CHASSIS For more information, please visit us at or us at

17 Uninterruptible Power Supply for Naval Ground Airborne Applications 12 TYPICAL 5U CHASSIS NOVA ELECTRIC Leader in power conversion technology since 1966 MADE IN USA

18 13 GALAXY SERIES 5-6 KVA TRUE ON-LINE UPS 5, 6 KVA Militarized Rack Mount True Online UPS with External Battery Drawers APPLICATIONS Nova s transformer isolated Galaxy -Series UPS Systems are high-reliability power sources specifically designed for demanding applications in high shock, vibration, humidity, and EMI environments. They can be built to meet MIL-STD-810, MIL-S-901, MIL-STD-1472, MIL-STD-461, and other standards optionally. These models utilize True On-Line technology and the most durable componentry, offering maximum field-proven reliability for severe environment and high reliability applications such as: q SHELTERS q SHIPBOARD POWER q MOBILE SYSTEMS q TACTICAL SYSTEMS q HMMWVs q GROUND SUPPORT q MIL-STD-810 q MIL-S-901 q MIL-STD-461 q MIL-STD-167 For more information, please visit us at or us at novasales@theallpower.com

19 14 OPTIONS Emergency Power Off Circuit MS Connector Mates Chassis Slides Guides Internal Solid State Transfer Switch Premium 10 Year Life Wide Temperature Range Batteries RS232 or SNMP Run Time to 24+ Hours Three Phase Input Custom Cabinets & Turnkey Solutions Rail Frequency Hz - 83, 91.66, 100, 200, or 250 Hz. PROTECTIVE FEATURES AC & DC Input Circuit Breakers Low Battery Shut Off Overload & Thermal Protected Input Under/Overvoltage Protected Audible Alarm with Silence Switch. MODEL KVA INPUT ELECTRICAL Frequency: Specify 50, 60, or 400Hz Voltage Regulation: ± 1% NL to FL Frequency Regulation: ± 0.5% NL to FL Harmonic Distortion: 5% THD Power Factor: 0.7 lead to 0.7 lag Efficiency at full load: 75-80% typical Overload: 125% for 5 minutes ELECTRICAL BATTERIES 7 High x 19 Wide x 21 Deep Rack Mount battery drawers containing sealed,maintenance-free, user replaceable batteries rated for 3-5 years lifetime. Battery cabinets and racks also available with run time from 5 minutes to 24+ hours MODEL SELECTION INPUT AMPS UPS LBS. MECHANICAL SPECIFICATIONS ENVIRONMENTAL Operating Temp.: -20 to +50 C Storage Temp. Range: -20 to +50 C (extended range available) Humidity: to 95% non-condensing Elevation: 15,000 Ft. (4,572m) operating; 40,000 ft. (12,192m) non-operating Shock: 20g/11mS Audible Noise: Less than 55 dba at 5 ft. DIAGNOSTIC Alarm Contacts: Standard RS 232 or SNMP: Optional BATTERY STD. RUN TIME GRS11-5K VAC 66A 120 VAC, 60 Hz 200 PC5K Min. 225 GRS11-5K VAC 39A 220 VAC, 50 Hz 200 PC5K Min. 188 GRS11-5K VAC 66A 115 VAC, 400 Hz 200 PC5K Min. 225 GRS11-5K60-120/ /208 VAC 23A 120 VAC, 60 Hz 200 PC5K Min. 225 GRS11-6K VAC 79A 120 VAC, 60 Hz 225 PC5K Min. 225 GRS11-6K VAC 47A 220 VAC, 50 Hz 225 PC5K Min. 188 GRS11-6K VAC 79A 115 VAC, 400 Hz 225 PC5K Min. 225 BATTERY LBS. GRS11-6K60-120/ /208 VAC 28A 120 VAC, 60 Hz 225 PC5K Min. 225 NOTES: 1. ALL DIMENSIONS ARE IN INCHES. 2. EXTERIOR COLOR ANSI #61 GRAY. TYPICAL 5-6 KVA UPS CHASSIS.12 AC/DC VOLTMETER SEE TOP COVER SCREEN BELOW FOR DETAILS AIR INTAKE (BOTH SIDES) #5/16-18 THD HOLE FOR LIFTING EYE BOLTS PROVIDED (2) PL. BOTH SIDES J4 ALARM CONTACTS DE-9SMS J3 DC INPUT MS3102R VOLTMETER SWITCH SYSTEM STATUS (GREEN/RED) 8.72 BATTERY INPUT CIRCUIT BREAKER 8.72 ALARM SILENCE SWITCH J1 AC INPUT MS3102R INDICATORS (SEE CAPTION) CHASSIS SLIDE GENERAL DEVICE P/N: CTHRS-122 (OPTIONAL) EXHAUST FANS GROUND STUD 1/4-20 WITH WING NUT J2 AC MS3102R.50 NOVA ELECTRIC Leader in power conversion technology since 1966 MADE IN USA

20 15 GALAXY SERIES KVA TRUE ON-LINE UPS KVA Three Phase UPS System APPLICATIONS Nova s Rugged, True On-Line Galaxy-Series Rack-Mount UPS Systems are available in Three-Phase output configuration. The UPS Systems can be packaged in various ways, including custom cabinet enclosures. Any run time up to 24 hours is available upon request. Please contact the factory for more details We will work to provide you with the perfect UPS for your industrial / commercial / Militarized application! q SHELTERS q SHIPBOARD POWER q MOBILE SYSTEMS q TACTICAL SYSTEMS q HMMWVs q GROUND SUPPORT q MIL-STD-810 q MIL-S-901 q MIL-STD-461 q MIL-STD-167 For more information, please visit us at or us at novasales@theallpower.com

21 16 OPTIONS MS Connector Mates Chassis Slides External Solid State Transfer Switch (5.25 High x 19 Wide x 17 Deep) Premium 10 Year Life Wide Temperature Range Batteries RS232 or SNMP Run Time to 24+ Hours Custom Painting and Plating Custom Cabinets & Turnkey Solutions PROTECTIVE FEATURES AC & DC Input Circuit Breakers Low Battery Shut Off Overload & Thermal Protected Input Under/Overvoltage Protected Audible Alarm with Silence Switch. ELECTRICAL Input: 120/208, 220/380 or 115/200 VAC Frequency: 50, 60, or 400Hz Voltage Regulation: ± 2% NL to FL Frequency Regulation: ± 0.5% NL to FL Harmonic Distortion: 5% THD Power Factor: 0.7 lead to 0.7 lag Efficiency at full load: 75-80% typical Overload: 125% for 5 minutes ELECTRICAL BATTERIES 7 High x 19 Wide x 21 Deep Rack Mount battery drawers containing sealed, maintenance-free, user replaceable batteries rated for 3-5 years lifetime. Battery cabinets and racks also available with run time from 5 minutes to 24+ hours. MODEL SELECTION ENVIRONMENTAL Operating Temp.: -20 to +50 C Storage Temp. Range: -20 to +50 C (extended range available) Humidity: to 95% non-condensing Elevation: 15,000 Ft. (4,572m) operating; 40,000 ft. (12,192m) non-operating Shock: 20g/11mS Audible Noise: Less than 55 dba at 5 ft. DIAGNOSTIC Alarm Contacts: Standard RS 232 or SNMP: Optional MODEL KVA INPUT UPS LBS. GRSL11-3K3/6-120/ / /208 VAC, 60 Hz 120/208 VAC, 60 Hz 165 GRSL11-3K3/5-220/ / /380 VAC, 50 Hz 220/380 VAC, 50 Hz 165 GRSL11-3K3/4-115/ / /200 VAC, 400 Hz 115/200 VAC, 400 Hz 165 GRSL11-5K3/6-120/ / /208 VAC, 60 Hz 120/208 VAC, 60 Hz 175 GRSL11-5K3/5-220/ / /380 VAC, 50 Hz 220/380 VAC, 50 Hz 175 GRSL11-5K3/4-115/ / /200 VAC, 400 Hz 115/200 VAC, 400 Hz 175 GRSL11-8K3/6-120/ / /208 VAC, 60 Hz 120/208 VAC, 60 Hz 185 GRSL11-8K3/5-220/ / /380 VAC, 50 Hz 220/380 VAC, 50 Hz 185 GRSL11-8K3/4-115/ / /200 VAC, 400 Hz 115/200 VAC, 400 Hz 185 MECHANICAL SPECIFICATIONS NOVA ELECTRIC Leader in power conversion technology since 1966 MADE IN USA

22 17 NAVY GALAXY SERIES TRUE ON-LINE UPS POWER FACTOR CORRECTED & GALVANICALLY ISOLATED 1.5KVA & 2.5KVA 19 RACK MOUNT 3 U HIGH APPLICATIONS This rugged Navy Galaxy-Series UPS System is specifically designed for submarine and shipboard applications in compliance to MIL-STD-1399, MIL-STD-461, MIL-S-901, MIL-STD-167, MIL-STD-810, and MIL-STD-740. The example pictured is a compact 2.5 KVA unit built for use on submarines, as well as other high profile shipboard and submarine applications in US and US-friendly fleets worldwide. This model has a three-phase power factor corrected (PFC) input of 115 VAC L-L, 50/60 Hz per MIL-STD-1399 Section 300 Type I and a pure sinewave galvanically isolated output of 115 VAC, Single-Phase. Single-phase input is optional, and output frequency is available in 50, 60, or 400 Hz (specify.) This UPS System contains all of the features standard on other Galaxy-Series units, as well as additional features that make it ideal for Naval applications. ADVANCED FEATURES q AUTOMATIC DC OFFSET q TWO STAGE BATTERY CHARGER q TOTALLY MODULAR DESIGN q INPUT INRUSH CURRENT CONTROL q SYNCHRONIZED PFC MODULES q EFFICIENCY EXCEEDING 80% For more information, please visit us at or us at novasales@theallpower.com

23 18 OPTIONS Single Phase Input RS232 or SNMP Interface Monitoring Software Chassis Slides MS Connector Mates High Speed Mechanical Transfer Switch Custom Painting and Markings PROTECTIVE FEATURES AC & DC Input Circuit Breakers Low Battery Shut Off Overload & Thermal Protected Audible Alarm with Silence Switch ALARMS & DIAGNOSTICS System Status: Green/Red Utility Off: Red UPS Off: Red Low Battery: Red Logic Fault: Red UPS Overload: Red Over-Temperature: Red Load on Utility: Red (with XFR SW option) ELECTRICAL Optional Input Voltages available (select): 115, 120, 208, 220, 230, 240 VAC. 1Ø 115/200, 120/208, 220/380 3Ø Optional Input Frequencies available (specify): 50, 60 or 400 Hz Optional Output Voltages Available (specify): 115, 120, 208, 220, 230, 240 VAC 1Ø Output Frequency (specify): 50, 60 or 400Hz Voltage Regulation: ± 2% NL to FL Frequency Regulation: 0.1% Harmonic Distortion: 2% THD Typical 5% Max Input Power Factor: 0.99 at full load Efficiency at full load: 82% typical Overload: 125% for 5 minutes INTERNAL BATTERIES Premium 10 year life wide temp batteries which are sealed, maintenance- free, and user replaceable. MODEL SELECTION ENVIRONMENTAL Operating Temp: -20 to +50 C per MIL-STD-810D Storage Temp Range: -40 to +71 C Humidity: to 95% non-condensing Elevation: 15,000 Ft. (4,572m) operating 40,000Ft. (12,192m) non-operating Audible Noise: Less than 55 dba at 5 ft. Cooling: Forced air (exhaust at rear) Airflow 200 CFM Maximum EMI: per MIL-STD-461B/E Vibration: per IEC Type I Shock: 20g for 20mS half sinewave per MIL-S-901C Grade A Structureborne noise: MIL-STD-740B Grade A MTBF: 100,000+ hours per field data MTTR: 30 minutes PARTIAL MODEL SELECTION KVA INPUT UPS LBS. RUN TIME NGRS11-1.5K VAC 115 VAC min NGRS11-1.5K60-115(D) VAC L-L 115 VAC min NGRS11-2.5K VAC 115 VAC min NGRS11-2.5K60-115(D) VAC L-L 115 VAC min MECHANICAL SPECIFICATIONS NOVA ELECTRIC Leader in power conversion technology since 1966 MADE IN USA

24 19 NAVY GALAXY SERIES TRUE ON-LINE UPS POWER FACTOR CORRECTED & GALVANICALLY ISOLATED 5 KVA 19 RACK MOUNT 5 U HIGH APPLICATIONS This rugged Navy Galaxy-Series UPS System is specifically designed for submarine and shipboard applications in compliance to MIL-STD-1399, MIL-STD-461, MIL-STD-901, MIL-STD-167, MIL-STD-810, and MIL-STD-740. The example pictured is a compact 2.5 KVA unit built for use on submarines, as well as other high profile shipboard and submarine applications in US and US-friendly fleets worldwide. This model has a three-phase power factor corrected (PFC) input of 115 VAC L-L, 50/60 Hz per MIL- STD-1399 Section 300 Type I and a pure sinewave galvanically isolated output of 115 VAC, Single- Phase. Single-phase input is optional, and output frequency is available in 50, 60, or 400 Hz (specify.) This UPS System contains all of the features standard on other Galaxy-Series units, as well as additional features that make it ideal for Naval applications. ADVANCED FEATURES q AUTOMATIC DC OFFSET q TWO STAGE BATTERY CHARGER q TOTALLY MODULAR DESIGN q INPUT INRUSH CURRENT CONTROL q SYNCHRONIZED PFC MODULES q EFFICIENCY EXCEEDING 80% For more information, please visit us at or us at novasales@theallpower.com

25 20 OPTIONS Single Phase Input RS232 or SNMP Interface Monitoring Software Chassis Slides MS Connector Mates High Speed Mechanical Transfer Switch Custom Painting and Markings PROTECTIVE FEATURES AC & DC Input Circuit Breakers Low Battery Shut Off Overload & Thermal Protected Audible Alarm with Silence Switch. Optional EPO ALARMS & DIAGNOSTICS System Status: Green/Red Utility Off: Red UPS Off: Red Low Battery: Red Logic Fault: Red UPS Overload: Red Over-Temperature: Red Load on Utility: Red (with XFR SW option) ELECTRICAL Optional Input Voltages available (select): 115, 120, 208, 220, 230, 240 VAC. 1Ø 115/200, 120/208, 220/380 3Ø Optional Input Frequencies available (specify): 50, 60 or 400 Hz Optional Output Voltages Available (specify): 115, 120, 208, 220, 230, 240 VAC 1Ø Output Frequency (specify): 50, 60 or 400Hz Voltage Regulation: ± 2% NL to FL Frequency Regulation: 0.1% Harmonic Distortion: 2% THD Typical 5% Max Input Power Factor: 0.99 at full load Efficiency at full load: 82% typical Overload: 125% for 5 minutes EXTERNAL BATTERIES Premium 10 year life wide temp batteries which are sealed, maintenance- free, and user replaceable. MODEL SELECTION ENVIRONMENTAL Operating Temp: -20 to +50 C per MIL-STD-810D Storage Temp Range: -40 to +60 C Humidity: to 95% non-condensing Elevation: 15,000 Ft. (4,572m) operating 40,000Ft. (12,192m) non-operating Audible Noise: Less than 55 dba at 5 ft. Cooling: Forced air (exhaust at rear) Airflow 200 CFM Maximum EMI: per MIL-STD-461B/E Vibration: per IEC Type I Shock: 20g for 20mS half sinewave per MIL-S-901C Grade A Structureborne noise: MIL-STD-740B Grade A MTBF: 100,000+ hours per field data MTTR: 30 minutes PARTIAL MODEL SELECTION KVA INPUT UPS LBS. RUN TIME BATTERY LBS. NGRS11-5K60-115(D) VAC L-L 115 VAC min 120 MECHANICAL SPECIFICATIONS NOVA ELECTRIC Leader in power conversion technology since 1966 MADE IN USA

26 21 NAVY GALAXY SERIES TRUE ON-LINE UPS APPLICATIONS This rugged Navy Galaxy-Series UPS System is specifically designed for submarine and shipboard applications in compliance to MIL-STD-1399, MIL-STD-461, MIL-STD-901, MIL-STD-167, MIL-STD-464, MIL-STD-810, and MIL-STD-740. The example pictured is a compact variation for use on the US Navy DDG-1000, as well as other high profile shipboard and submarine applications on US and US-friendly fleets worldwide. This model has a three-phase power factor corrected (PFC) input of 115 VAC L-L, 50/60 Hz per MIL-STD-1399 Section 300 Type I and a pure sinewave galvanically isolated output of 115 VAC, Single- Phase. Single-phase input is optional, and output frequency is available in 50, 60, or 400 Hz (specify.) This UPS System contains all of the features standard on other Galaxy-Series units, as well as additional features that make it ideal for Naval or other military applications. ADVANCED FEATURES q q AUTOMATIC DC OFFSET TOTALLY MODULAR DESIGN q SYNCHRONIZED PFC MODULES q TWO STAGE BATTERY CHARGER q INPUT INRUSH CURRENT CONTROL q EFFICIENCY EXCEEDING 80% POWER FACTOR CORRECTED & GALVANICALLY ISOLATED 1.5KVA & 2.5KVA BULKHEAD MOUNT For more information, please visit us at or us at novasales@theallpower.com

27 22 OPTIONS Single Phase Input RS 232 or SNMP Interface MS Connector Mates High Speed Mechanical Transfer Switch Wide temperature range Shock mounts Manual bypass switch External bypass switch Custom Paint & Markings ALARMS & DIAGNOSTICS System Status: Green/Red Utility Off: Red UPS Off: Red Low Battery: Red Logic Fault: Red Alarm Contacts: Standard RS 232 or SNMP: Optional UPS Overload: Red Over-Temperature: Red Load on Utility: Red (with XFR SW option) ELECTRICAL Optional Input Voltages available (select): 115, 120, 208, 220, 230, 240 VAC. 1Ø 115/200, 120/208, 220/380 3Ø Optional Input Frequencies available (specify): 50, 60 or 400 Hz Optional Output Voltages Available (specify): 115, 120, 208, 220, 230, 240 VAC 1Ø Output Frequency (specify): 50, 60 or 400Hz Voltage Regulation: ± 2% NL to FL Frequency Regulation: 0.1% Harmonic Distortion: 2% THD Typical 5% Max Input Power Factor: 0.99 at full load Efficiency at full load: 82% typical Overload: 125% for 5 minutes INTERNAL BATTERIES Premium wide temp batteries which are sealed, maintenance free, and user replaceable. Extended runtime available. MODEL SELECTION ENVIRONMENTAL Operating Temp: -20 to +50 C per MIL-STD-810 Storage Temp Range: -40 to +60 C Humidity: to 95% non-condensing Elevation: 15,000 Ft. (4,572m) operating 40,000 Ft. (12,192m) non-operating Audible Noise: Less than 55 dba at 5 ft. Cooling: Forced air EMI: per MIL-STD-461 Vibration: per MIL-STD-167 Shock: 20g for 20mS half sinewave Per MIL-S-901D Grade A Structureborne noise: MIL-STD-740B Grade A MTBF: 100,000+ hours per field data MTTR: 30 minutes PARTIAL MODEL SELECTION KVA INPUT UPS (Lbs.) RUN TIME NGHS11-1.5K VAC 120 VAC min NGHS11-1.5K60-115(D) VAC L-L 120 VAC min NGHRS11-2.5K VAC 120 VAC min NGHS11-2.5K60-115(D) VAC L-L 120 VAC min MECHANICAL SPECIFICATIONS NOVA ELECTRIC Leader in power conversion technology since 1966 MADE IN USA

28 23 JUPITER SERIES FREESTANDING UPS 10KVA TO 450+ KVA THREE PHASE 50/60/400 Hz Sine-wave Single Phase available on special order GALVANIC ISOLATED APPLICATIONS Nova UPSs are high-reliability power sources specifically designed for demanding applications in high shock, vibration, humidity, and EMI environments. They can be built to meet MIL-STD-810, MIL-STD-1399, MIL-STD-1472, MIL-STD-461, and other standards optionally. q MILITARY APPLICATIONS VEHICULAR SHIPBOARD q AC POWER FROM VEHICLE BATTERY q COMMUNICATIONS q SHELTERS q UTILITY APPLICATIONS q EMERGENCY LIGHTING FEATURES Complete input to output Galvanic isolation. Almost silent high frequency operation Push button starting and stopping Diagnostic panel with LCD and LED display Soft start on inverter Maintenance free batteries True On-Line Operation Solid state transfer switch built-in Maintenance bypass switch built-in Overload and short circuit protection All electronics are built in modular front access and front removable sub assemblies for easy service and maintenance Batteries may be built into units up to 20KVA Automatic dual rate battery charger (float charge and boost charge) Remote isolated dry relay contacts Available options to meet military specs For more information, please visit us at or us at novasales@theallpower.com

29 JUPITER SERIES FREESTANDING UPS MONITORING FEATURES 24 The UPS includes an RS232 communication option called UPSCOM. This is an RS232 connection to a PC that can monitor information related to the UPS output and any abnormal conditions that have occurred in real time.standard commercially available software is provided. The RS232 feature is included at no additional charge. FRONT PANEL LCD DISPLAY AND LED INDICATORS - These will report all UPS parameters, including input and output voltages, currents, frequency, DC voltage and many other functions. LCD DISPLAY - Real time status, data, and historical events are displayed via the LCD display. The UPS parameters, real-time clock, inverter, and buzzer can also be set through this LCD, which is backlit by LEDs for visual clarity. STATUS LEDs - LEDs representing all important operational information provide feedback to the user. LED descriptions are as follows: UPS ON UPS is running normally. UPS SS UPS static switch is on while the reserve static switch is opened (off). SHORT CIRCUIT UPS output is in short circuit state. FUSE / OVERTEMP SD UPS has shut down due to either fuse open or over temperature. UPS FAIL SHUT DOWN UPS has shut down due to low UPS AC output voltage. BYPASS ON SHUT DOWN UPS shut down due to closed bypass breaker. UPS shut down due closed bypass breaker (while inverter running). HIGH DC SHUT DOWN UPS shut down due to high DC bus. OVERLOAD SHUT DOWN UPS shutdown due to overload of the inverter for a period greater than the inverter can accept. The UPS will start after 7 seconds. 70% LOAD load connected to the output is over 70% of the inverter rating. 110% LOAD load connected to the output is over 110% of the inverter rating. 125% LOAD load connected to the output is over 125% of the inverter rating. 150% LOAD load connected to the output is over 150% of the inverter rating. RESERVE AC FAIL reserve AC magnitude is out of range. RESERVE FREQ FAIL reserve frequency is out of range. BATTERY LOW - DC bus (or battery) is lower than specified range. Low battery shut down will occur soon. BATTERY LOW SHUT DOWN inverter shutdown due to DC bus (or battery) lower than the acceptable DC voltage of the inverter. HIGH DC DC voltage over the acceptable DC voltage of the inverter. EMERGENCY STOP Inverter shut down activated by emergency stop switch. DATA LINE Blink when data is transmitted to or received from the communication port. WARNING LEDs When abnormal condition occurs, these LEDs will light to warn the user of the cause of the fault condition. Therefore all these LEDs are off under normal condition. These LEDs are: RESERVE FAIL Reserve AC input is abnormal either due to AC magnitude out of range or frequency out of range. FUSE/TEMP - Either inverter fuse is open or over temperature has occurred. OVERLOAD Output is overloaded by over 110%, 125% or 150% HIGH DC This LED will light when DC input approaches high-line limit. BAT LOW This LED will light when the DC voltage is low. BAT LOW STOP This LED will light when the DC voltage is lower than specified range. FAULT T The inverter is off due to abnormal conditions such as overload, short circuit, high DC, fuse over temperature, bypass breaker on emergency stop. Since these LEDs are located behind the transparent window, the user can use them clearly without opening the door.audible ALARM The audible alarm will beep under either one of the following conditions: INVERTER IS OVERLOADED 110% beep once every 3 seconds 125% beep once every second 150% beep twice every second INVERTER IS SHORT CIRCUITED Beeps continuously FUSE OPEN Beeps continuously HEAT SINK OVER TEMPERATURE Beeps continuously HIGH DC SHUTDOWN Beeps continuously BYPASS ON STOP Beeps continuously EMERGENCY ON STOP Beeps continuously. The buzzer will also beep once every time the UPS is switched on or off to acknowledge to the user that his key entry is valid and accepted. Since these LEDs are located behind the transparent window, the user can use them clearly without opening the door. NOVA ELECTRIC Leader in power conversion technology since 1966 MADE IN USA

30 25 JUPITER SERIES FREESTANDING UPS COMMUNICATION OPTIONS We offer options for communications with this Inverter series. Some popular options available at additional cost include the following: UPSCAN This is a hand held remote display and control module with LCD and LED display that can monitor via RS-485 up to 99 UPS Units at a remote distance of up to 3,000 feet. NETAGENT This provides capability to monitor the Inverter over the internet. It includes the appropriate additional SNMP card and microprocessor. The software required is provided by MEGATEC at additional cost. OTHER OPTIONS CASTERS & LEVELERS For portability, the 22 wide Jupiter cabinets may be optionally equipped with the base-mounted caster / leveler set as shown here. DC INPUT BREAKER OPTION / BATTERY FUSE The optional DC Input breaker disconnect or fuse is offered to provide protection for the DC Battery connection. One or the other must be ordered. SHOCK MOUNT OPTION The cabinet can be shock mounted, using optional rubber on coil type isolators. This will be enable the unit to withstand shock levels as specified in MIL-STD-901 RUGGEDIZING OPTION This option will add conformal coating and other additional internal structural members to allow the unit to meet many portions of MIL-STD-810. TURN ON SERVICE OPTION We offer a turn on service that will ensure the UPS has been properly installed and the full warranty is in effect (failures caused by incorrect installation are not covered by the warranty.) If this option is selected, the customer will also automatically receive an additional 3 months added to the warranty at no additional charge. SPARE PARTS KIT OPTION We offer a spare parts package that includes one of each board, spare fuses, spare semiconductors, and spare fans. These spare part kits are priced lower when ordered with the initial order then if they are ordered later on. TYPICAL VIEW OF JUPITER SERIES UPS, INVERTERS AND BATTERY CHARGERS For more information, please visit us at or us at novasales@theallpower.com

31 JUPITER SERIES FREESTANDING UPS 26 FREESTANDING UPS 3 PHASE INPUT / 3 PHASE KVA /320 PHASE BATTERY INVERTER STATIC SWITCH OVERALL CHARACTERISTICS Input Voltage (VAC) Input Range Input Frequency Input Frequency Range Power Walk In Please Specify 120/ / / / / Phase delta Phase delta Phase delta Phase delta ± 20% (>+20% is available upon request) Please Specify: 50 Hz or 60 Hz Hz (optional) ± 5% (wider ranges offered, please consult factory) 0% - 100%: 20 sec Voltage Regulation 1% Efficiency 98% Rectification Type 6 Pulse Standard, 12 Pulse Optional 12 Pulse Standard Battery Type Maximum Charge Current (Adc Selectable) LO, MED, HI Battery Start Output Voltage (VAC) Wave Form Maintenance free lead-acid batteries / 12V x 29pcs. (348 VDC Nominal) Yes, UPS can be started without AC source. Please Specify 120/ / / / / Phase delta Phase delta Phase delta Phase delta Sinewave Output Power Factor 0.8 Frequency Lock Range Output Frequncy (Free Running) OVERLOAD Phase Shift Under 100% Unbalanced Load ± 5% (alternate ranges offered on special order) Please Specify: 50 Hz or 60 Hz or 400 Hz (crystal controlled) , 100 or 250 Hz optional 0.7 lead to lag <0.5% THD (Linear Load) <2% <110% Continuous % 15 minutes % 5 minutes > % 30 seconds > % 15 seconds Efficiency (100% Load) 93% 93.50% 94% 94.50% 95% Voltage Range Mains <-> Inverter Overload Same as Main Rectifer Input. (Different voltages are available upon request) 0 ms (True Online) As per inverter rating plus >200% to 300% = 1 second Overall Efficiency 91% 91.50% 92% 92.50% 93% Maximum Heat Dissipation (KW) Full Load 2.4 K 4.8 K 6.5 K 8.9 K 10.3 K 12 K 16 K 19 K 22 K 30 K 45 K 60 K Audible Noise < 65 dba (at 1 m) < 67 dba (at 1 m) Temperature Humidity Altitude MTTR -10 C to +50 C (Extended ranges available) 0%-95% (Non-condensing) <1500 m Above Sea Level Less Than 30 minutes IEC Yes for 220/380VAC 50Hz Models No EN ,-2 Short Circuit Protection Lighting / EMC Filter MOV / Input & Output ( FCC CLASS A) Galvanic Isolation Yes Yes Input and Output True Galvanic Isolation Remote Control/ Communication Interface Monitoring 1~99 Units simultaneously / Dry Contact, RS-232, RS-485 (Optional) NOVA ELECTRIC Leader in power conversion technology since 1966 MADE IN USA

32 27 JUPITER SERIES FREESTANDING UPS 60 Hz MODEL KVA KW IN/OUT (VAC) DIMENSIONS (HxWxD) BATTERY UPS WEIGHT RUN BATTERY WEIGHT BATTERY TIME DIMMENSIONS Kg. Lbs. (MIN) (H x W x D) Kg. Lbs. J11-10K3/6-120/ /208-10M / x x J11-20K3/6-120/ /208-10M / x x J11-30K3/6-120/ / / x x J11-30K3/6-120/ / / x x J11-30K3/6-120/ / / x x J11-40K3/6-120/ / / x x J11-40K3/6-120/ / / x x J11-40K3/6-120/ / / x x J11-50K3/6-120/ / / x x J11-50K3/6-120/ / / x x J11-60K3/6-120/ / / x x J11-60K3/6-120/ / / x x J11-80K3/6-120/ / / x x J11-100K3/6-120/ / / x x J11-120K3/6-120/ / / x x J11-160K3/6-120/ / / x x J11-200K3/6-277/ / / x x J11-240K3/6-277/ / / x x J11-240K3/6-277/ / / x x J11-300K3/6-277/ / / x x J11-320K3/6-277/ / / x x J11-320K3/6-277/ / / x x HR V 29 pcs. HR V 58 pcs. 12V 26AH 29 pcs. 12V 26AH 58 pcs. 12V 75AH 29 pcs. 12V 26AH 29 pcs. 12V 26AH 58 pcs. 12V 75AH 29 pcs. 12V 26AH 58 pcs. 12V 75AH 29 pcs. 12V 26AH 58 pcs. 12V 75AH 29 pcs. 12V 75AH 29 pcs. 12V 88AH 29 pcs. 12V 100AH 29 pcs. 12V 75AH 58 pcs. 12V 88AH 58 pcs. 12V 100AH 58 pcs. 12V 75AH 87 pcs. 12V 88AH 87 pcs. 12V 88AH 87 pcs. 12V 100AH 87 pcs. CONTACT FACTORY FOR SINGLE PHASE MODELS 10 Internal Internal x x x x x x x x x x x x x x x x x x x x x x x x x x x 2 x (43.50 ) x x 2 x (43.50 ) x x 2 x (43.50 ) x x 3 x (43.50 ) x x 3 x (43.50 ) x x 3 x (43.50 ) x x 3 x (43.50 ) x For more information, please visit us at or us at novasales@theallpower.com

33 JUPITER SERIES FREESTANDING UPS Hz MODEL KVA KW IN/OUT (VAC) DIMENSIONS (HxWxD) BATTERY UPS WEIGHT RUN BATTERY WEIGHT BATTERY TIME DIMMENSIONS Kg. Lbs. (MIN) (H x W x D) Kg. Lbs. J11-10K3/5-220/ /380-10M / x x J11-20K3/5-220/ /380-10M / x x J11-30K3/5-220/ / / x x J11-30K3/5-220/ / / x x J11-30K3/5-220/ / / x x J11-40K3/5-220/ / / x x J11-40K3/5-220/ / / x x J11-40K3/5-220/ / / x x J11-50K3/5-220/ / / x x J11-50K3/5-220/ / / x x J11-60K3/5-220/ / / x x J11-60K3/5-220/ / / x x J11-80K3/5-220/ / / x x J11-100K3/5-220/ / / x x J11-120K3/5-220/ / / x x J11-160K3/5-220/ / / x x J11-200K3/5-220/ / / x x J11-240K3/5-220/ / / x x J11-240K3/5-220/ / / x x J11-300K3/5-220/ / / x x J11-320K3/5-220/ / / x x J11-320K3/5-220/ / / x x HR V 29 pcs. HR V 58 pcs. 12V 26AH 29 pcs. 12V 26AH 58 pcs. 12V 75AH 29 pcs. 12V 26AH 29 pcs. 12V 26AH 58 pcs. 12V 75AH 29 pcs. 12V 26AH 58 pcs. 12V 75AH 29 pcs. 12V 26AH 58 pcs. 12V 75AH 29 pcs. 12V 75AH 29 pcs. 12V 88AH 29 pcs. 12V 100AH 29 pcs. 12V 75AH 58 pcs. 12V 88AH 58 pcs. 12V 100AH 58 pcs. 12V 75AH 87 pcs. 12V 88AH 87 pcs. 12V 88AH 87 pcs. 12V 100AH 87 pcs. 10 Internal Internal x x x x x x x x x x x x x x x x x x x x x x x x x x x 2 x (43.50 ) x x 2 x (43.50 ) x x 2 x (43.50 ) x x 3 x (43.50 ) x x 3 x (43.50 ) x x 3 x (43.50 ) x x 3 x (43.50 ) x NOVA ELECTRIC Leader in power conversion technology since 1966 MADE IN USA

34 129 JUPITER SERIES FREESTANDING UPS TYPICAL DIMENSION DRAWINGS (22 WIDE) For more information, please visit us at or us at

35 JUPITER SERIES FREESTANDING UPS 30 TYPICAL DIMENSION DRAWINGS (43.5 WIDE) NOVA ELECTRIC Leader in power conversion technology since 1966 MADE IN USA

36 31 JUPITER SERIES FREESTANDING UPS TYPICAL DIMENSION DRAWINGS (87 WIDE) For more information, please visit us at or us at

37 JUPITER SERIES FREESTANDING UPS 32 TYPICAL DIMENSION DRAWINGS (87 WIDE) NOVA ELECTRIC Leader in power conversion technology since 1966 MADE IN USA

38 33 JUPITER SERIES FREESTANDING UPS ETL Certified to UL /208 VAC, 60 Hz, 3 Phase ETL CERTIFIED TO UL 1778 APPLICATIONS Nova s Jupiter-Series UPS Systems are highreliability power sources specifically designed for demanding commercial, heavy industrial, and military applications. They can be built to meet MIL-STD-810, MIL-S-901, MIL-STD-461, and other standards optionally. These models utilize True On- Line technology and the most durable components, offering maximum field-proven reliability for severe environment and high reliability applications. q MILITARY APPLICATIONS VEHICULAR SHIPBOARD q AC POWER FROM VEHICLE BATTERY q COMMUNICATIONS q SHELTERS q UTILITY APPLICATIONS q EMERGENCY LIGHTING FEATURES Complete input to output Galvanic isolation. High frequency almost silent operation Push button starting and stopping Diagnostic panel with LCD and LED display Soft start on inverter Overload & and short circuit protection on charger and inverter Maintenance free batteries True On-Line Operation Maintenance bypass switch built-in at no additional charge Solid state transfer switch built-in at no additional charge All electronics are built in modular front access and front removable sub assemblies for easy service and maintenance Batteries may be built into units up to 20KVA Automatic dual rate battery charger (float charge and boost charge) FCC class A approved Remote isolated dry relay contacts For more information, please visit us at or us at novasales@theallpower.com

39 JUPITER SERIES FREESTANDING UPS ETL Certified to UL 1778 MONITORING FEATURES 34 The UPS includes an RS232 communication option called UPSCOM. This is an RS232 connection to a PC that can monitor information related to the UPS output and any abnormal conditions that have occurred in real time.standard commercially available software is provided. The RS232 feature is included at no additional charge. FRONT PANEL LCD DISPLAY AND LED INDICATORS - These will report all UPS parameters, including input and output voltages, currents, frequency, DC voltage and many other functions. LCD DISPLAY - Real time status, data, and historical events are displayed via the LCD display. The UPS parameters, real-time clock, inverter, and buzzer can also be set through this LCD, which is backlit by LEDs for visual clarity. STATUS LEDs - LEDs representing all important operational information provide feedback to the user. LED descriptions are as follows: UPS ON UPS is running normally. UPS SS UPS static switch is on while the reserve static switch is opened (off). SHORT CIRCUIT UPS output is in short circuit state. FUSE / OVERTEMP SD UPS has shut down due to either fuse open or over temperature. UPS FAIL SHUT DOWN UPS has shut down due to low UPS AC output voltage. BYPASS ON SHUT DOWN UPS shut down due to closed bypass breaker. UPS shut down due closed bypass breaker (while inverter running). HIGH DC SHUT DOWN UPS shut down due to high DC bus. OVERLOAD SHUT DOWN UPS shutdown due to overload of the inverter for a period greater than the inverter can accept. The UPS will start after 7 seconds. 70% LOAD load connected to the output is over 70% of the inverter rating. 110% LOAD load connected to the output is over 110% of the inverter rating. 125% LOAD load connected to the output is over 125% of the inverter rating. 150% LOAD load connected to the output is over 150% of the inverter rating. RESERVE AC FAIL reserve AC magnitude is out of range. RESERVE FREQ FAIL reserve frequency is out of range. BATTERY LOW - DC bus (or battery) is lower than specified range. Low battery shut down will occur soon. BATTERY LOW SHUT DOWN inverter shutdown due to DC bus (or battery) lower than the acceptable DC voltage of the inverter. HIGH DC DC voltage over the acceptable DC voltage of the inverter. EMERGENCY STOP Inverter shut down activated by emergency stop switch. DATA LINE Blink when data is transmitted to or received from the communication port. WARNING LEDs When abnormal condition occurs, these LEDs will light to warn the user of the cause of the fault condition. Therefore all these LEDs are off under normal condition. These LEDs are: RESERVE FAIL Reserve AC input is abnormal either due to AC magnitude out of range or frequency out of range. FUSE/TEMP - Either inverter fuse is open or over temperature has occurred. OVERLOAD Output is overloaded by over 110%, 125% or 150% HIGH DC This LED will light when DC input approaches high-line limit. BAT LOW This LED will light when the DC voltage is low. BAT LOW STOP This LED will light when the DC voltage is lower than specified range. FAULT T The inverter is off due to abnormal conditions such as overload, short circuit, high DC, fuse over temperature, bypass breaker on emergency stop. Since these LEDs are located behind the transparent window, the user can use them clearly without opening the door.audible ALARM The audible alarm will beep under either one of the following conditions: INVERTER IS OVERLOADED 110% beep once every 3 seconds 125% beep once every second 150% beep twice every second INVERTER IS SHORT CIRCUITED Beeps continuously FUSE OPEN Beeps continuously HEAT SINK OVER TEMPERATURE Beeps continuously HIGH DC SHUTDOWN Beeps continuously BYPASS ON STOP Beeps continuously EMERGENCY ON STOP Beeps continuously. The buzzer will also beep once every time the UPS is switched on or off to acknowledge to the user that his key entry is valid and accepted. Since these LEDs are located behind the transparent window, the user can use them clearly without opening the door. NOVA ELECTRIC Leader in power conversion technology since 1966 MADE IN USA

40 35 JUPITER SERIES FREESTANDING UPS ETL Certified to UL 1778 COMMUNICATION OPTIONS We offer options for communications with this Inverter series. Some popular options available at additional cost include the following: UPSCAN This is a hand held remote display and control module with LCD and LED display that can monitor via RS-485 up to 99 UPS Units at a remote distance of up to 3,000 feet. NETAGENT This provides capability to monitor the Inverter over the internet. It includes the appropriate additional SNMP card and microprocessor. The software required is provided by MEGATEC at additional cost. OTHER OPTIONS DC INPUT BREAKER OPTION / BATTERY FUSE The optional DC Input breaker disconnect or fuse is offered to provide protection for the DC Battery connection. One or the other must be ordered. TURN ON SERVICE OPTION We offer a turn on service that will ensure the UPS has been properly installed and the full warranty is in effect (failures caused by incorrect installation are not covered by the warranty.) If this option is selected, the customer will also automatically receive an additional 3 months added to the warranty at no additional charge. SPARE PARTS KIT OPTION We offer a spare parts package that includes one of each board, spare fuses, spare semiconductors, and spare fans. These spare part kits are priced lower when ordered with the initial order then if they are ordered later on. TYPICAL VIEW OF JUPITER SERIES UPS, INVERTERS AND BATTERY CHARGERS For more information, please visit us at or us at novasales@theallpower.com

41 JUPITER SERIES FREESTANDING UPS ETL Certified to UL FREESTANDING UPS 3 PHASE INPUT / 3 PHASE KVA PHASE BATTERY INVERTER OVERALL CHARACTERISTICS Input Voltage (VAC) Input Range Input Frequency Input Frequency Range Power Walk In 120/208 VAC ± 20% (>+20% is available upon request) Please Specify: 50 Hz or 60 Hz Hz (optional) ± 5% (wider ranges offered, please consult factory) 0% - 100%: 20 sec Voltage Regulation 1% Efficiency 98% Rectification Type Battery Type Maximum Charge Current (Adc Selectable) LO, MED, HI Battery Start 6 Pulse Standard, 12 Pulse Optional Maintenance free lead-acid batteries/ 12V (348 VDC Nominal) Yes, UPS can be started without AC source. Output Voltage (VAC) 120/208 Wave Form Sinewave Output Power Factor 0.8 Frequency Lock Range Output Frequncy (Free Running) OVERLOAD Phase Shift Under 100% Unbalanced Load 50 / 60 Hz +/- 3 Hz 50 / 60 Hz +0.1Hz (crystal controlled) 0.7 lead to lag <0.5% THD (Linear Load) <2% <110% Continuous % UP TO 15 minutes % UP TO 5 minutes > % UP TO 30 seconds > % UP TO 15 seconds Overall Efficiency 91% 91.5% 92% Maximum Heat Dissipation (KW) Full Load 2.4 K 3.6K 4.8K 6.5K 8.9K 10.3K 12K Audible Noise < 65 dba (at 1 m) Temperature Humidity Altitude MTTR EN ,-2 Short Circuit Protection 0-40ºC (32-104ºF)(Other ranges available) 0%-95% (Non-condensing) <1500 m Above Sea Level Less Than 30 minutes Lighting / EMC Filter MOV / Input & Output ( FCC CLASS A) Galvanic Isolation Yes Yes Input and Output True Galvanic Isolation Remote Control/ Communication Interface LED, LCD, Audible Alarm Monitoring 1~99 Units simultaneously / Dry Contact, RS-232, RS-485 (Optional) YES NOVA ELECTRIC Leader in power conversion technology since 1966 MADE IN USA

42 37 Standard ETL Model Selection: JUPITER SERIES FREESTANDING UPS ETL Certified to UL Hz MODEL KVA KW IN/OUT (VAC) DIMENSIONS (HxWxD) BATTERY UPS WEIGHT RUN BATTERY WEIGHT BATTERY TIME DIMMENSIONS Kg. Lbs. (MIN) (H x W x D) Kg. Lbs. JE11-10K3/6-120/ /208-10M / x 22 x JE11-10K3/6-120/ /208-20M / x 22 x JE11-15K3/6-120/ /208-5M / x 22 x JE11-15K3/6-120/ /208-15M / x 22 x JE11-20K3/6-120/ /208-10M / x 22 x JE11-30K3/6-120/ / / x 22 x JE11-30K3/6-120/ / / x 22 x JE11-30K3/6-120/ / / x 22 x JE11-40K3/6-120/ / / x 22 x JE11-40K3/6-120/ / / x 22 x JE11-40K3/6-120/ / / x 22 x JE11-50K3/6-120/ / / x 22 x JE11-50K3/6-120/ / / x 22 x JE11-60K3/6-120/ / / x 22 x JE11-60K3/6-120/ / / x 22 x HR V 29pcs HR V 58pcs HR V 29pcs HR V 58pcs HR V 58pcs 12V 26AH 29pcs 12V 26AH 58pcs 12V 75AH 29pcs 12V 26AH 29pcs 12V 26AH 58pcs 12V 75AH 29pcs 12V 26AH 58pcs 12V 75AH 29pcs 12V 26AH 58pcs 12V 75AH 29pcs 10 Internal Internal Internal Internal Internal x 22 x x 22 x x 22 x x 22 x x 22 x x 22 x x 22 x x 22 x x 22 x x 22 x Note: Any UPS can be used with larger batteries to obtain higher run times. 75AH, 88AH and 100AH batteries are also available. Consult factory for run times. For more information, please visit us at or us at novasales@theallpower.com

43 JUPITER SERIES FREESTANDING UPS ETL Certified to UL 1778 TYPICAL DIMENSION DRAWINGS (22 WIDE) 38 NOVA ELECTRIC Leader in power conversion technology since 1966 MADE IN USA

44 39 NERM Series MODULAR UPS SYSTEMS 10 KVA to 400 KVA (For 220/380 VAC Power Systems) 6 KVA to 240 KVA (For 120/208 VAC Power Systems) APPLICATIONS Nova Electric s NERM-Series True Online UPS provides a modular backup solution for data centers, computer systems, and any other critical equipment which demands dependable backup power. The NERM s state of the art design combines the latest IGBT three-level technology along with modern DSP Control for maximum reliability, low THD-i, and extremely high system efficiency. Modules can be stacked from 6 KVA to 400 KVA, offering hot-swappable flexibility with the highest quality, at a price you can afford. Power expansion is very simple to achieve by adding more individual power modules to the system, which can reach 200 KVA power in a single rack. Two racks can be paralleled for 400 KVA power. STANDARD FEATURES High input power factor (>0.99) with low input THD-i (<3%). Low adaptability for linear and nonlinear load. Low audible noise system design (<55db). Double DSP controller for each individual power module. Digital control for all major UPS subassemblies including rectifier, inverter, battery charger, and battery discharge. IGBT modules rather than discrete semiconductor components are used in the power module for high reliability. 6 MODULE CABINET Conformal coated boards for humidity resistance. Built in PDU circuit breakers for cabinet AC input, AC output and maintenance bypass. Digital paralleling technology with very low circulating current between power modules. Front access cabinet with both top and bottom cable connections. Each individual module is configured with an independent DSP controller to avoid single point of failure risk. Generator-friendly interface. RS232, 485, and dry contacts all standard For more information, please visit us at or us at novasales@theallpower.com

45 NERM Series MODULAR UPS SYSTEMS 40 PARTIAL OPTION SELECTION VRLA batteries in modular drawers. Battery circuit breaker. SNMP communication card. Battery temperature compensation module. User replaceable air filter for dusty environments. Parallel operation kit. Input isolation transformer. Alternate remote shutdown / EPO configurations. Battery cold start module (Allows the UPS to start on battery alone). HIGH RELIABILITY DESIGN The low-loss integrated three-level IGBTs used in each NERM Series power module result in higher efficiency and enhaced reliability due to lower heatsink temperatures. MODULE FEATURES NERM MODULE Hot swap building block 12 KVA and 6 KVA 120/208 VAC and 20 KVA and 10 KVA 220/380 VAC Independent control. Designed for parallel operation with active current sharing. Designed for (N+1) redundancy. Capable of hot swap. Automatic mechanical disconnection in case of failure or maintenance. THE MODULAR HOT SWAP DESIGN Each UPS power module is designed to be hot swappable for hassle -free power expansion and system maintenance. Each module is controlled independently, thus avoiding a single point failure risk. If any individual module fails or disconnects, the system continues to operate and supply power without interruption, ensuring a high level of reliability and protection. EASY OPERATION AND INSTALLATION The modular flexibility of the NERM-Series UPS dramatically reduces technician time spent on installation and maintenance. A large touchscreen LCD panel ensures that users can quickly and easily access vital information. INTELLIGENT BATTERY MANAGEMENT Each UPS module contains a powerful 3.2 KW battery charger, and up to ten modules can be paralleled for 32 KW maximum battery charging capacity. These chargers are DSP controlled with intelligent digital algorithms designed specifically to prolong battery life. THE SMART PROTECTION SYSTEM Each individual power module and the overall system are protected by both hardware and software. Protection functions include abnormal current, incorrect input or output voltage, over temperature, and short circuit. The combination of these hardware and software protection functions results in extremely high reliability, with a very user friendly interface. 10 MODULE CABINET NOVA ELECTRIC Leader in power conversion technology since 1966 MADE IN USA

46 41 NERM Series MODULAR UPS SYSTEMS SPECIFICATION & MODEL SELECTION 220/380 VAC Thru 277/480 VAC Models Capacity KVA (to 400 KVA with 2 racks) MAIN INPUT Input voltage (with neutral) 220/380, 230/400, 240/415 or 277/480 VAC (with optional transformer) Input frequency 50/60 Hz Input Power factor >0.99 Input current THD (Total Harmonic Distortion) <3% Input voltage window -20% to +20% at full load; -40% to +20% at 70% load or less Frequency window HZ Programmable BATTERY Battery voltage ±240 VDC (Nominal) Charger power 20%*Power Charger voltage precision 1% BYPASS Bypass voltage 220/380, 230/400, 240/415 or 277/480 VAC (with optional transformer) Bypass voltage window -20%~ +15%, full load, settable < 125%, long term operation (2 hours maximum) 125%<load<130%, for more than 1 hour Bypass overload capability 130%<load<150%, for more than 6 minutes >1000%, for more than 100 ms Output voltage 220/380, 230/400, 240/415 or 277/480 VAC (with optional transformer) Voltage precision ±0.5% (balanced load), ±1% (unbalanced load) Voltage THD (Total Harmonic Distortion) THD<1.5% (linear load), THD<5% (nonlinear load) Power factor 0.8 Phase tolerance 120 ±0.5 (balance and unbalance load) Crest factor 3:1 Up to 105%, continuous operation Up to 110%, transfer to bypass after 1hour Overload capability Up to 125%, transfer to bypass after 10 minutes Up to 150%, transfer to bypass after 1 minute >150%, transfer to bypass after 200 ms SYSTEM Normal mode: 95% System efficiency ECO mode: 99% Battery mode efficiency 95% Display LCD+LED, Touch screen and keyboard IP class IP20 Interface (Communication Ports) RS232, RS485, Dry Contacts, SNMP Card, EPO, Generator Interface Installation/Connection Top or bottom cable connection Operation temperature 0-40 C (to 50 C with 15% derating) Storage temperature (Electronics) -25 C to +70 C (Battery may be different) Relative humidity 0-95% (non-condensing) Noise (db) <55dB Weight (kg/lb) Note: Cabinets do not need to be fully populated Dimension (W*D*H)(mm/inch) 6 Module Cabinet NERM060/10,RM090/15,NERM120/20 150kg/330Lb 10 Module Cabinet NERM100/10,RM150/15,NERM200/20 180kg/396Lb NEPM10 10KVA 20kg/44Lb NEPM20 20KVA 22kg/49Lb 6-module Cabinet 600*900*1600 / 23.6*35.5*63 10-module Cabinet 600*900*2000 / 23.6*35.5*78.8 Module (10/20 KVA) 440*600*134 / 17.3*23.6*5.27 For more information, please visit us at or us at novasales@theallpower.com

47 Capacity Input voltage (with neutral) Input frequency NERM Series 42 MODULAR UPS SYSTEMS SPECIFICATION & MODEL SELECTION 120/208 VAC Models 220/380 VAC Thru 277/ KVA (to VAC 240 KVA with Models 2 racks) MAIN INPUT 120/208 VAC 50/60 Hz Input Power factor >0.99 Input current THD (Total Harmonic Distortion) <3% Input voltage window -20% to +20% at full load, -40% to +20% at 70% load or less Frequency window HZ Programmable BATTERY Battery voltage ±120 VDC (Nominal) Charger power 20%*Power Charger voltage precision 1% BYPASS Bypass voltage 120/208 VAC Bypass voltage window -20%~ +15%, full load, settable < 125%, long term operation (2 hours maximum) 125%<load<130%, for more than 1 hour Bypass overload capability 130%<load<150%, for more than 6 minutes >1000%, for more than 100 ms Output voltage 120/208 VAC Voltage precision ±1% (balance load), ±2% (unbalance load) Voltage THD (Total Harmonic Distortion) Voltage THD (Total Harmonic Distortion), THD<2% (linear load), THD<5% (nonlinear load) Power factor 0.8 Phase tolerance 120 ±0.5 (balance and unbalance load) Crest factor 3:1 Up to 105%, continuous operation Up to 110%, transfer to bypass after 1hour Overload capability Up to 125%, transfer to bypass after 10 minutes Up to 150%, transfer to bypass after 1 minute >150%, transfer to bypass after 200 ms SYSTEM Normal mode: 90% System efficiency ECO mode: 99% Battery mode efficiency 90% Display LCD+LED, Touch screen and keyboard IP class IP20 Interface (Communication Ports) RS232, RS485, Dry Contacts, SNMP Card, EPO, Generator Interface Installation/Connection Top or bottom cable connection Operation temperature 0-40 C (to 50 C with 15% derating) Storage temperature (Electronics) -25 C to +70 C (Battery may be different) Relative humidity 0-95% (non-condensing) Noise (db) <55dB Weight (kg/lb) Note: Cabinets do not need to be fully populated Dimension (W*D*H)(mm/inch) 6 Module Cabinet NERM036/06L, NERM072/12L 150kg/330Lb 10 Module Cabinet NERM072/06L, NERM120/12L 180kg/390Lb NEPM06L 6KVA 20kg/44Lb NEPM12L 12KVA 22kg/49Lb 6-module Cabinet 600*900*1600 / 23.6*35.5*63 10-module Cabinet 600*900*2000 / 23.6*35.5*78.8 Module (6/12 KVA) 440*600*134 / 17.3*23.6*5.27 NOVA ELECTRIC Leader in power conversion technology since 1966 MADE IN USA

48 43 AET UPS SERIES 1 KVA KVA UL LISTED C True, Double-Conversion, On-Line UPS 19 INCH RACK MOUNT AND TOWER CONFIGURATION Flexible Mounting Orientation Allows system integrators more flexibility in designing their backup power system to maximize space. With the rotatable LCD design, the user can mount the UPS vertically or horizontally. 19 Rack Mount adapters are included with each unit. Chassis Slides are optional. User-Friendly Graphic LCD This robust LCD display enables field service engineers to easily troubleshoot the UPS without opening the box thus reducing downtime. APPLICATIONS Communication Equipment Network Servers Computers Workstations Wireless Communications Other Electronic Pheripherals Single Voltage Battery Pack Design A 48 VDC standard battery pack design comprised of 4 x 12V7AH is used in all AET series UPS models and are interchangeable with each other. Additional battery drawers can be added to increase battery runtime. Hot-Swappable Battery The standard 48 VDC battery pack allows installers to take the headache out of battery installation. Installers can now simply slide the used battery pack out of the unit and replace it with a new pack. All AET battery packs are interchangeable reducing the risk of system failures. Light Weight Design The AET Model is specially designed for field installation. The light weight design requires only a single installer to put the system in place. This will significantly reduce on-the-job injuries and installation fees. User-Remote Interface The off-site user can now test, set parameters, monitor power status, save files, and shutdown the system all via the remote interface. The user-remote interface includes SNMP/HTTP Card, RS232, USB, DB9, and AS400 interface. Cruiser Software (Included) Users are able to customize the various Cruiser controls such as warning method, alarm messages and several shortcut icons to easily access the most commonly used functions. For more information, please visit us at or us at novasales@theallpower.com

49 SPECIFICATIONS Long back-up battery maximizes extended runtime Topology PARTIAL MODEL NAME AET11-1.5K AET11-1.6K AET11-2.2K AET11-2.5K AET11-3K AET11-3.2K On-battery Output Waveform True On-Line, Double Conversion True Sine Wave Number of Phase Single (1 Phase 2W + G) INPUT Maximum Capacity (VA/W) 1500 VA/1050 W 1600 VA/1120 W 2200 VA/1540 W 2500 VA/1750 W 3000 VA/2100 W 3200 VA/2240 W Nominal Input Voltage 120 VAC 230 VAC 120 VAC 230 VAC 120 VAC 230 VAC Input Voltage Range VAC VAC VAC VAC VAC VAC Nominal Input Frequency 50/60 Hz ± 5 Hz Input PFC > full load Input Short Protection Circuit Breaker on front of the UPS Nominal Output Voltage 100/110/115/120 VAC 208/220/230/240 VAC 100/110/115/120 VAC 208/220/230/240 VAC 100/110/115/120 VAC 208/220/230/240 VAC Output Voltage Regulation Rated Voltage ± 2 % Output T.H.D. < 3 Linear Load High Effciency Mode (AC to AC) > 86 % > 88 % > 88% Crest Factor 3 : 1 Start on Battery YES Output Frequency 50/60 Hz (Autotracking) Overload Capability Sustaining at least 120 seconds at % load, % max 12 seconds. Imidiate shutdown and transfer of load to bypass at 150% load. Auto transfer back to UPS when overload is removed. BATTERY User Replaceable Battery 1 x 48 VDC Battery Pack 96V (2 x 48VDC) Battery Pack 96V (2 x 48VDC) Battery Pack Typical Back-up Time (Full/Half Load) 6/17 min 9/26 min 6/17 min Battery Type Sealed VRLA 12V7AH; Hot Swap Recharge Time to 90% 8 Hours Extended Battery Cabinet Extendible Battery Module in 2U high (comprises 2x48VDC Battery Packs) Operation Transition from or to battery operation is accomplished with no interruption of power to the load. Upon restoration of input power, the UPS will automatically resume normal operation and recharge the battery. ADVANCE WARNING DIAGNOSTICS Front Panel Indication Front panel menu driven LCD monitoring and control panel for all functions. Audible Alarms DC Mode, Low Battery, voltage / Frequency Error, Charger Fail, Over Load, Fault, PFC Overload COMMUNICATION INTERFACE Communication Port RS Port (Standard); DB9, AS400, USB Cards (optional) SNMP Manageable YES ENVIRONMENTAL Temperature (Operation/Storage) 0 ºC to + 40 ºC / -15 to + 50 ºC Relative Humidity 0% to 95% non-condesing Altitude Up to 10,000 ft (3,000 meters) at up to 40 ºC, without derating Audible Noise < 45 1 meter MECHANICAL 44 Dimensions ( W x H x D) Note: Change W to 19 for Rack Mount Configuration 426 x 88(2U) x 500 (mm) x 3.46(2U) x 19.7 (in) 426 x 176(4U) x 500 (mm) x 6.93(4U) x 19.7 (in) 426 x 176(4U) x 500 (mm) x 6.93(4U) x 19.7 (in) Weight (UPS/Battery Packs) 26.4 / 24.6 lb 12 / 11.2 Kgs 29 / 68.7 lb 13.2 / 31.2 Kgs 29.5 / 69 lb 13.4 / 31.4 Kgs Total Weight 51 lb 23.2 Kgs 97.7 lb 44.4 Kgs 98.5 lb 44.6 Kgs CONFORMANCE EMI/RFI Compatibility FCC Part 15 Class B (1.5KVA, 2.2KVA, 3KVA Models) EN Class B, EN55022B, IEC/EN (Harmonic Current) (1.6KVA, 2.5KVA, 3.2KVA Models) Safety UL, cul (CSA) (1.5KVA, 2.2KVA, 3KVA Models) CE, TUV, GS (1.6KVA, 2.5KVA, 3.2KVA Models) NOVA ELECTRIC Leader in power conversion technology since 1966 MADE IN USA

50 45 CGLUPS SERIES RUGGED LIGHTWEIGHT DC INPUT UPS 1.5-2KW V INPUT PURE SINEWAVE AC 19 RACK MOUNT APPLICATIONS The CGLUPS DC Input rugged, military UPS is intended for military applications wherever pure sinewave batterybacked AC power is required directly from a DC input source. 28 VDC from Aircraft buss or Land Vehicle alternator feeds the CGLUPS and charges the batteries via diode isolation module, which blocks the batteries from feeding back onto the 28 VDC source. If the DC source is lost, the DC UPS continues powering the load using its internal batteries for approximately 5 minutes at full load, 0.8PF. Nova s CGLUPS-Series DC Input rugged, military UPS systems are high-reliability power sources specifically designed for demanding applications in high shock, vibration, humidity, and EMI environments. These rugged, military UPS systems can be built to meet MIL-STD-810, MIL-STD-1399, MIL-S-901, MIL-STD-1472, MIL-STD-461, and other standards optionally. These rugged UPS models utilize the most durable componentry, offering maximum fieldproven reliability for severe, harsh environments and high reliability applications such as: q SHELTERS q SHIPBOARD POWER q GROUND SUPPORT q AIRCRAFT/UAVs q HMMWVs q HEAVY DUTY INDUSTRIAL q TACTICAL SYSTEMS q MOBILE SYSTEMS q DEMANDING COMMERCIAL q COMMUNICATION SYSTEMS For more information, please visit us at or us at novasales@theallpower.com

51 46 FEATURES Microprocessor based design with absolutely accurate and stable frequency Panel indicators for battery voltage & load level Compact and light weight, yet very rugged Tightly regulated output voltage and frequency Switch selectable 50 or 60 Hz output, all models Capable of driving highly reactive loads such as electric tools and appliances. Capable of driving highly capacitive loads such as switching power supplies. Very low harmonic distortion, THD<3% Standard DC input 20-32VDC Standard outputs 110V/60Hz, 230V/50Hz. Switch selectable ±10V output change. Below 1W consumption in sleep mode. OPTIONAL FEATURES Panel indicators for battery voltage & load level Compact and light weight, yet very rugged SPECIFICATIONS Input Voltage: VDC Output Voltage: 100/110/120 VAC (110V Model) 220/230/240 VAC (220V Model) Output Frequency: 50 or 60 HZ User Selectable ±0.05% Accuracy Surge Rating: 2KW for 1.5KW Continous Models 4KW for 2KW Continuous Models Efficiency (full load): 83% (110V Model) 86% (220V Model) No load Current: <1.0W Sleep Mode Output Waveform Sinewave: <3% THD Output Regulation: -10% / +4% All models Protection: Overload, Short Circuit, Reverse Polarity (Fuse), O.T., Over/Under Input Voltage MTBF: 30,000 hours per MIL-HDBK-217 MTTR: 30 minutes by qualified personnel ENVIRONMENTAL Ambient operating temperature range: -20 to +50 C Storage temp. range: -40 to +60 C (w/optional premium batteries) Humidity: to 95% RH non-condensing - Designed to meet MIL-STD-810. All boards conformal coated with Acrylic MIL-I Type R. Shock: 20g, 11 ms half sinewave - Designed to meet MIL-STD-810 optionally EMI: Designed to meet FCC Part 15, Class A. Designed to meet MIL-STD-461 with optional additional filtering. Elevation: 15,000 ft. (4,572 m) operating** 40,000 ft. (12,192 m), non-operating** Audible noise: Less than 55 dba at 5 ft. (1.5 m) Transportation and handling: MIL-STD-810C **Follow manufacturer instructions regarding recommended elevation parameters for batteries. MODEL SELECTION 120 VAC MODELS 220 VAC MODELS MODEL INPUT RANGE (VDC) VAC FREQ. (Hz) CONTINUOUS POWER RUN TIME MODEL INPUT RANGE (VDC) VAC FREQ. (Hz) CONTINUOUS POWER RUN TIME CGLUPS-1.5K or KW 5 min CGLUPS-2K or 60 2 KW 4 min CGLUPS-1.5K or KW 5 min CGLUPS-2K or 60 2 KW 4 min MECHANICAL SPECIFICATIONS NOVA ELECTRIC Leader in power conversion technology since 1966 MADE IN USA

52 47 RCGL2K SERIES RUGGED PURE-SINEWAVE INVERTER 12, 24 OR 48 VDC INPUT 120V OR 220V 1Ø 50 Hz or 60 Hz APPLICATIONS The RCGL (pure sine wave) inverters are intended for commercial, industrial or military applications wherever standard utility-like power is needed at 50 or 60 Hz. These inverters are ideal for running electronic loads such as computers, monitors, printers, telecom systems, radios, fluorescent lamps from batteries, field generators, and solar electro-voltaic panels. They can also drive hand drills, motors and small compressors. This unit can be ruggedized against shock, vibration and humidity optionally for mobile applications. Utilizing field proven technology, this family of rugged pure sinewave DC-AC Inverters is suitable for harsh environments and can be customized for unique applications including: q MILITARY SHELTERS q GROUND SUPPORT q MOBILE SYSTEMS q TACTICAL SYSTEMS q UTILITY APPLICATIONS q COMMUNICATIONS q MIL-STD-810 q MIL-STD-461 For more information, please visit us at or us at novasales@theallpower.com

53 48 STANDARD FEATURES Microprocessor based design with absolutely accurate and stable frequency. Panel LED s for battery voltage & load level. Compact and light weight, yet rugged and vehicle rated % efficient. Tightly regulated output voltage and frequency Switch selectable 50 or 60 Hz output. Capable of driving highly reactive loads such as electric tools and appliances. Capable of driving highly capacitive loads such as switching power supplies. Very low harmonic distortion, THD<3%. Suitable for vehicle mounting. Switch selectable ±10V output change. Load Controlled Cooling fan. ELECTRICAL Input Voltage: 12, 24 or 48 V Output Voltage 110V model: 100/110/120 VAC Output Voltage 220V model: 220/230/240 VAC Output Frequency: 50 or 60 HZ (User Selectable % Accuracy) Continuous Power Rating: 2000W Surge Rating: 4000W Efficiency 120V model (full load): 93% Efficiency 220V model (full load): 95% No load Current: <1.0W Sleep Mode Output Waveform Sinewave: <3% THD Output Regulation: ±3% MTBF: over 100,000 hours per field data MTTR: 30 minutes PROTECTIVE FEATURES Overload Short Circuit Reverse Polarity (Fuse) O.T, Over/Under Input Voltage. MODEL SELECTION ENVIRONMENTAL Operating Temperature: -20 C to +50 C Storage Temperature: -40 C to + 71 C Shock: 20g / 11mS per MIL-STD-810 Vibration: per MIL-STD-810 Humidity: per MIL-STD-810 to 95% non condensing EMI: per MIL-STD-461 CE102, CS101, CS114, CS115, CS116, RE102, and RS103 POPULAR OPTIONS MS Connector Mates Chassis Slides Additional Ruggedization against Shock/Vibration / Humidity to MIL-STD-810 Weatherproofing Package (Sealed Breakers / Switches, additional dust filtration, and louvered air intake / exhaust for protection from splashing water Internal Electromechanical Transfer Switch MODEL INPUT RANGE VDC VAC FREQ. (Hz) CONTINUOUS POWER APPROX. WEIGHT (Lb.) SIZE (H x W x L) (INCHES) RCGL-2K or 60 2 KW 29 Lb x x RCGL-2K or 60 2 KW 29 Lb x x RCGL-2K or 60 2 KW 29 Lb x x RCGL-2K or 60 2 KW 29 Lb x x RCGL-2K or 60 2 KW 29 Lb x x RCGL-2K or 60 2 KW 29 Lb x x MECHANICAL SPECIFICATIONS NOVA ELECTRIC Leader in power conversion technology since 1966 MADE IN USA

54 49 RCGL3K SERIES RUGGED PURE-SINEWAVE INVERTER 24 OR 48 VDC INPUT 120V OR 220V 1Ø 50 Hz or 60 Hz APPLICATIONS The RCGL (pure sine wave) inverters are intended for commercial, industrial or military applications wherever standard utility-like power is needed at 50 or 60 Hz. These inverters are ideal for running electronic loads such as computers, monitors, printers, telecom systems, radios, fluorescent lamps from batteries, field generators, and solar electro-voltaic panels. They can also drive hand drills, motors and small compressors. This unit can be ruggedized against shock, vibration and humidity optionally for mobile applications. Utilizing field proven technology, this family of rugged pure sinewave DC-AC Inverters is suitable for harsh environments and can be customized for unique applications including: q MILITARY SHELTERS q GROUND SUPPORT q MOBILE SYSTEMS q TACTICAL SYSTEMS q UTILITY APPLICATIONS q COMMUNICATIONS q MIL-STD-810 q MIL-STD-461 For more information, please visit us at or us at novasales@theallpower.com

55 50 STANDARD FEATURES Microprocessor based design with absolutely stable frequency Panel LED s for battery voltage & load level Compact and light weight, yet rugged and vehicle rated 93-95% efficient Tightly regulated output voltage and frequency Switch selectable 50 or 60 Hz output Capable of driving highly reactive loads such as electric tools and appliances Capable of driving highly capacitive loads such as switching power supplies Very low harmonic distortion, THD<3% Suitable for vehicle mounting Switch selectable ±10V output change Load Controlled Cooling fan ELECTRICAL Input Voltage: 12, 24 or 48 V Output Voltage 110V model: 100/110/120 VAC Output Voltage 220V model: 220/230/240 VAC Output Frequency: 50 or 60 HZ (User Selectable +.05% Accuracy) Continuous Power Rating: 2000W Surge Rating: 4000W Efficiency 120V model (full load): 93% Efficiency 220V model (full load): 95% No load Current: <1.0W Sleep Mode Output Waveform Sinewave: <3% THD Output Regulation: ±3% MTBF: over 100,000 hours per field data MTTR: 30 minutes PROTECTIVE FEATURES Overload Short Circuit Reverse Polarity (Fuse) O.T, Over/Under Input Voltage MODEL SELECTION ENVIRONMENTAL Operating Temperature: -20 C to +50 C Storage Temperature: -40 C to + 71 C Shock: 20g / 11mS per MIL-STD-810 Vibration: per MIL-STD-810 Humidity: per MIL-STD-810 to 95% non condensing EMI: per MIL-STD-461 CE102, CS101, CS114, CS115, CS116, RE102, and RS103 POPULAR OPTIONS MS Connector Mates Chassis Slides Additional Ruggedization against Shock / Vibration/ Humidity to MIL-STD-810 Weatherproofing Package (Sealed Breakers /Switches, additional dust filtration, and louvered air intake / exhaust for protection from splashing water Internal Electromechanical Transfer Switch MODEL INPUT RANGE VDC VAC FREQ. (Hz) CONTINUOUS POWER APPROX. WEIGHT (Lb.) SIZE (H x W x L) (INCHES) RCGL-3K or 60 3 KW 29 Lb x x RCGL-3K or 60 3 KW 29 Lb x x RCGL-3K or 60 3 KW 29 Lb x x RCGL-3K or 60 3 KW 29 Lb x x MECHANICAL SPECIFICATIONS NOVA ELECTRIC Leader in power conversion technology since 1966 MADE IN USA

56 51 OCGL SERIES RUGGED PORTABLE OUTDOOR DC-AC INVERTERS 24 OR 48 VDC INPUT 120V OR 220V 1Ø 50 Hz or 60 Hz APPLICATIONS The OCGL (pure sine wave) inverters are intended for outdoor military or industrial applications wherever standard utility-like power is needed at 50 or 60 Hz. These inverters are ideal for running electronic loads such as computers, monitors, printers, telecom systems, radios, fluorescent lamps from batteries, field generators, and solar electro-voltaic panels. They can also drive hand drills, motors and small compressors. These units can be ruggedized against shock, vibration and humidity optionally for mobile applications and offer IP54 protection from the elements. Utilizing field proven technology, this family of rugged pure sinewave DC-AC Inverters is suitable for harsh environments and can be customized for unique applications including: q MILITARY SHELTERS q GROUND SUPPORT q MOBILE SYSTEMS q TACTICAL SYSTEMS q UTILITY APPLICATIONS q COMMUNICATIONS q MIL-STD-810 q MIL-STD-461 For more information, please visit us at or us at novasales@theallpower.com

57 52 FEATURES Microprocessor based design with absolutely accurate and stable frequency Compact and light weight, yet rugged and vehicle rated 89-95% efficient. Tightly regulated output voltage and frequency Switch selectable 50 or 60 Hz output Capable of driving highly reactive loads such as electric tools and appliances Capable of driving highly capacitive loads such as switching power supplies Very low harmonic distortion, THD <3% Suitable for vehicle or wall mounting IP Rating: 54 (higher ratings optional) ELECTRICAL Input Voltage: 12, 24 or 48 V Output Voltage 110V model: 100/110/120 VAC Output Voltage 220V model: 220/230/240 VAC Output Frequency: 50 or 60 HZ ± 0.05% Accuracy 2KW Surge Rating: 4000W 3KW Surge Rating: 6000W No load Current: <1.0W Sleep Mode Output Waveform Sinewave: <3% THD Output Regulation: -10% / +4% All models MTBF: over 100,000 hours per field data MTTR: 30 minutes MODEL SELECTION PROTECTIVE FEATURES Overload Short Circuit Reverse Polarity (Fuse) O.T, Over/Under Input Voltage ENVIRONMENTAL Operating Temperature: -20 C to +50 C Storage Temperature: -40 C to + 71 C Shock: 20g / 11mS per MIL-STD-810 Vibration: per MIL-STD-810 (Munson Road Test) Humidity: per MIL-STD-810 to 95% non condensing EMI: per MIL-STD-461 CE102, CS101, CS114, CS115, CS116, RE102, and RS103 MODEL INPUT RANGE VDC VAC FREQ. (Hz) CONTINUOUS POWER EFFICIENCY (FULL LOAD) APPROX. WEIGHT (Lb.) SIZE (H x W x L) (INCHES) OCGL2K or 60 2 KW 89% 29 Lb x x OCGL2K or 60 2 KW 91% 29 Lb x x OCGL2K or 60 2 KW 92% 29 Lb x x OCGL3K or 60 3 KW 91% 34 Lb x x OCGL2K or 60 2 KW 94% 29 Lb x x OCGL3K or 60 3 KW 93% 34 Lb x x OCGL2K or 60 2 KW 93% 29 Lb x x OCGL3K or 60 3 KW 92% 34 Lb x x OCGL2K or 60 2 KW 95% 29 Lb x x OCGL3K or 60 3 KW 94% 34 Lb x x MECHANICAL SPECIFICATIONS NOVA ELECTRIC Leader in power conversion technology since 1966 MADE IN USA

58 53 GALAXY MIL SERIES RUGGED PURE-SINEWAVE DC-AC INVERTERS VDC (MIL-STD-1275 OPTIONAL) INPUT 120V OR 220V 1Ø 50 Hz, 60 Hz or 400 Hz APPLICATIONS The Galaxy-MIL Series Inverters are extremely rugged by design, and built to withstand the rigors of harsh environment military applications where MIL-STD-461 and MIL-STD-810 apply. MIL-STD-1275 is optional as well. The units are ultra reliable and used worldwide on a variety of high profile mission critical applications where light weight, high MTBF, and low MTTR are called for. They can be easily customized with a variety of options to fit almost any application from vehicular to aircraft. q MILITARY SHELTERS q GROUND SUPPORT q MOBILE SYSTEMS q TACTICAL SYSTEMS q UTILITY APPLICATIONS q COMMUNICATIONS q MIL-STD-810 q MIL-STD-461 For more information, please visit us at or us at novasales@theallpower.com

59 54 FEATURES Pure Sinewave Output Small Size & Light Weight for Portability High reliability: MTBF: 30,000+ Hours per MIL-HDBK-217 MTTR: 30 Minutes (assuming qualified tech) OV, O.L. and O.T. protected Withstands high reactive load Tight voltage and frequency regulation Output fault alarm (relay closure) All boards conformal coated with Acrylic MIL-I Type AR OPTIONS MS Mating Connectors Special output voltages and frequencies Provision for 3 Phase connection with 2 more identical units 19 Panel mount or wall mount plates Alternative connectors Custom painting and marking Non-PVC wiring Transfer switch to alternate AC source External EMI filter box ELECTRICAL Input: 20-32VDC (MIL-STD-1275 Optional) Output: 120VAC (220VAC optional) Frequency: Specify 50, 60, or 400Hz Voltage Regulation: ± 1.5% NL to FL Frequency Regulation: ± 0.5% NL to FL Efficiency at full load: 85-86% typical Reactive Load: 0.7 Lead to 0.7 Lag Distortion: 5% THD, 3% Single Harmonic Overload: 125% for 5 minutes Sync & Phase Lock Range: +/-3 Hz Transient Response: Approx. 1/4 cycle recovery to 95% of nominal PROTECTIVE FEATURES Automatic overload, short circuit Over-temperature protected Dust filters Output circuit breaker MODEL SELECTION ENVIRONMENTAL Op. Temp.: -32 to +50 C per MIL-STD-810 Storage Temp. Range: -40 to +80 C Humidity: to 95% RH non-condensing Elevation: 15,000 Ft. (4,572m) operating; 40,000 Ft. (12,192m) non-operating Audible Noise: Less than 55 dba at 5 ft. Rain & Dripping Water: to MIL-STD-810F Vibration: per MIL-STD-810F Shock: per MIL-STD-810F Fungus: to MIL-STD-810F Salt / Fog: per MIL-STD-810 Sand / Dust: per MIL-STD-810 EMI: Designed to meet MIL-STD-461 CE102, CS101, CS106, CS109, CS114, CS115, CS116, RE102, RS103 (with optional filtering box) MODEL INPUT VDC POWER APPROX. WEIGHT (Lb.) MECHANICAL SPECIFICATIONS SIZE (H x W x L) (INCHES) NGL600W MIL W 7 Lb x 9.50 x GL1K MIL KVA 15 Lb x x GL2.5K MIL KVA 35 Lb x x GL5K MIL KVA 65 Lb x x TYPICAL GL2.5K60-24-MIL EXTERNAL (OPTIONAL) EXTERNAL (OPTIONAL) NOVA ELECTRIC Leader in power conversion technology since 1966 MADE IN USA

60 55 GALAXY SERIES RUGGED PURE-SINEWAVE DC-AC INVERTERS VDC INPUT 120V OR 220V 1Ø 50 Hz, 60 Hz or 400 Hz APPLICATIONS The transformer isolated Galaxy Series Inverters are extremely rugged by design, and feature an optional advanced Internal Suppression Filter Network (ISFN) to suppress the significant transients usually associated with rail and military applications. The units are also extremely reliable, designed to provide many years of service in harsh shock, vibration, humidity, and EMI environments. Utilizing field proven technology, this family of rugged pure sinewave DC-AC Inverters is suitable for harsh environments and can be customized for unique applications including: q SHELTERS q GROUND SUPPORT q UTILITY APPLICATIONS q TACTICAL SYSTEMS q RAIL q CRANE APPLICATIONS q MIL-STD-810 q MIL-STD-461 q MOBILE SYSTEMS q MIL-STD-167 q MIL-STD-704 q MIL-S-901 (OPTIONAL) For more information, please visit us at or us at novasales@theallpower.com

61 56 HIGH RELIABILITY MTBF: 100,000 Hours MTBR: 30 Minutes (assuming qualified tech) ELECTRICAL Input: 62-84VDC Output: specify 120 or 220VAC 1Ø (Three-Phase Output Optional) Frequency: Specify 50, 60, or 400Hz Voltage Regulation: ± 2% NL to FL Frequency Regulation: ± 0.5% NL to FL Harmonic Distortion: 5% THD Power Factor: 0.7 lead to 0.7 lag Efficiency at full load: 75-88% typical Overload: 125% for 5 minutes PROTECTIVE FEATURES Current Limit Short Circuit Protection, Thermal Protection Semiconductor Protection ISFN (Optional) ENVIRONMENTAL Operating Temp.: -20 to +50 C Storage Temp. Range: -40 to +71 C Humidity: to 95% non-condensing Elevation: 15,000 Ft. (4,572m) operating; 40,000 ft. (12,192m) non-operating Shock: 20g for 11mS half sinewave Audible Noise: Less than 55 dba at 5 ft. OPTIONS Ruggedization Chassis Slides NEMA Cabinet Enclosures Additional Meters Input Transient Filter (ISFN) Transfer Switch STANDARD INDICATORS Output Volt & Amp Meters (GS/GH Models) Input Power On Lamp (GS/GH Models) MODEL SELECTION MODEL INPUT VDC POWER APPROX. WEIGHT (LB) SIZE (H x W x L) INCHES GS1K KVA x x GS1.5K KVA x x GS2K KVA x x GS2.5K KVA x x GS3K KVA x x GS5K KVA x x MECHANICAL SPECIFICATIONS TYPICAL 1-2KVA GS SERIES CHASSIS AIR EXHAUST FAN SEE TOP COVER SCREEN BELOW FOR DETAILS 2.25 AIR INTAKE (BOTH SIDES) REAR VIEW TERMINAL BLOCK SCREW SIZE #8-32 NOTES: CHASSIS SLIDES (BOTH SIDES) GENERAL DEVICES P/N: CTS-120 (OPTIONAL) 1. ALL DIMENSIONS ARE IN INCHES. 2. EXTERIOR ANSI# 61 GRAY SEMI-GLOSS. 3. HANDLES PROJECT 1.50 INCHES FROM PANEL SURFACE. 4. CHASSIS SLIDES OPTIONAL. NOVA ELECTRIC Leader in power conversion technology since 1966 MADE IN USA

62 57 GALAXY SERIES PURE-SINEWAVE DC-AC INVERTERS VDC INPUT 120V OR 220V 1Ø 50 Hz, 60 Hz or 400 Hz APPLICATIONS The transformer isolated Galaxy Series Inverters are extremely rugged by design, and feature an optional advanced Internal Suppression Filter Network (ISFN) to suppress the significant transients usually associated with rail and military applications. The units are also extremely reliable, designed to provide many years of service in harsh shock, vibration, humidity, and EMI environments. Utilizing field proven technology, this family of rugged pure sinewave DC-AC Inverters is suitable for harsh environments and can be customized for unique applications including: q SHELTERS q GROUND SUPPORT q UTILITY APPLICATIONS q TACTICAL SYSTEMS q RAIL q CRANE APPLICATIONS q MIL-STD-810 q MIL-STD-461 q MOBILE SYSTEMS q MIL-STD-167 q MIL-STD-704 q MIL-S-901 (OPTIONAL) For more information, please visit us at or us at novasales@theallpower.com

63 58 HIGH RELIABILITY MTBF: 100,000 Hours MTBR: 30 Minutes (assuming qualified tech) ELECTRICAL Input: 62-84VDC Output: specify 120 or 220VAC 1Ø (Three-Phase Output Optional) Frequency: Specify 50, 60, or 400Hz Voltage Regulation: ± 2% NL to FL Frequency Regulation: ± 0.5% NL to FL Harmonic Distortion: 5% THD Power Factor: 0.7 lead to 0.7 lag Efficiency at full load: 75-88% typical Overload: 125% for 5 minutes STANDARD INDICATORS Output Volt & Amp Meters (GS/GH Models) Input Power On Lamp (GS/GH Models) MODEL INPUT VDC VAC PROTECTIVE FEATURES Current Limit Short Circuit Protection, Thermal Protection Semiconductor Protection ISFN (Optional) ENVIRONMENTAL Operating Temp.: -20 to +50 C Storage Temp. Range: -40 to +71 C Humidity: to 95% non-condensing Elevation: 15,000 Ft. (4,572m) operating; 40,000 ft. (12,192m) non-operating Shock: 20g for 11mS half sinewave Audible Noise: Less than 55 dba at 5 ft. MODEL SELECTION FREQ. (Hz) CONTINUOUS POWER MECHANICAL SPECIFICATIONS OPTIONS Ruggedized to meet MIL-STD-810 shock,vibration and humidity ( R option) Wide temperature range -40 C to +71 C Special output voltages and frequencies Provision for 3 Phase connection with 2 more identical units MS Connectors or outlets Custom painting and marking Handles High inrush for motor start Transfer switch to alternate AC source Switchable 50/60 Hz output RS232 or SNMP Communication Output fault alarm (relay closure) APPROX. WEIGHT (LB) SIZE (H x W x L) INCHES GH VA x x 7.15 GH1K KVA x x 7.15 GH2K KVA x x 8.00 G3K KVA x x GH5K KVA x x GH7.5K KVA x x GH10K KVA x x GH15K KVA x x GH20K KVA C/F x x GH25K KVA C/F x x GH30K KVA C/F x x GH35K KVA C/F x x Typical 3-6KVA chassis NOVA ELECTRIC Leader in power conversion technology since 1966 MADE IN USA

64 59 GALAXY SERIES RUGGED PURE-SINEWAVE DC-AC INVERTERS VDC INPUT 120V OR 220V 1Ø 50 Hz, 60 Hz or 400 Hz APPLICATIONS The transformer isolated Galaxy Series rugged inverters are extreme military inverters and rail inverters by design, and feature an optional advanced Internal Suppression Filter Network (ISFN) to suppress the significant transients usually associated with rail and military applications. These rugged, military inverter units are also extremely reliable, designed to provide many years of service in harsh shock, vibration, humidity, and EMI environments. Utilizing field proven technology, this family of rugged, military, pure sinewave, DC-AC inverters are ruggedized military inverters suitable for harsh environments and can be customized for unique applications including: q MILITARY SHELTERS q GROUND SUPPORT q MOBILE SYSTEMS q TACTICAL SYSTEMS q UTILITY APPLICATIONS q COMMUNICATIONS q MIL-STD-810 q MIL-STD-461 q UTILITY POWER For more information, please visit us at or us at novasales@theallpower.com

65 60 ELECTRICAL Input: VDC Output: specify 120 or 220VAC 1Ø (Three-Phase Output Optional) Frequency: Specify 50, 60, or 400Hz Voltage Regulation: ± 2% NL to FL Frequency Regulation: ± 0.5% NL to FL Harmonic Distortion: 5% THD Power Factor: 0.7 lead to 0.7 lag Efficiency at full load: 75-88% typical Overload: 125% for 5 minutes STANDARD INDICATORS Output Volt & Amp Meters Input Power On Lamp HIGH-RELIABILITY MTBF: 100,000 Hours MTBR: 30 Minutes (assuming qualified tech) ENVIRONMENTAL Operating Temp.: -20 to +50 C (extended range optional) Storage Temp. Range: -40 to +71 C Humidity: to 95% non-condensing Elevation: 15,000 Ft. (4,572m) operating; 40,000 Ft. (12,192m) non-operating Shock: 20g for 11mS half sinewave Audible Noise: Less than 55 dba at 5 ft. PROTECTIVE FEATURES Current Limit Short Circuit Protection Thermal Protection Semiconductor Protection ISFN (Optional) MODEL SELECTION OPTIONS Ruggedized to meet MIL-STD-810 shock,vibration and humidity ( R option) Wide temperature range -40 C to +71 C Special output voltages and frequencies Provision for 3 Phase connection with 2 more identical units MS Connectors or outlets Custom painting and marking Handles High inrush for motor start Transfer switch to alternate AC source Chassis slides (rack mount models only) Switchable 50/60 Hz output RS232 or SNMP Communication Output fault alarm (relay closure) MODEL INPUT VDC POWER APPROX. WEIGHT (LB) SIZE (H x W x L) INCHES GS1K KVA x x GS1.5K KVA x x GS2K KVA x x GS2.5K KVA x x GS3K KVA x x GS5K KVA x x GH7.5K KVA x x GH10K KVA x x GH15K KVA x x GH20K KVA x x GH25K KVA x x GH30K KVA x x GH35K KVA x x MECHANICAL SPECIFICATIONS TYPICAL 1-2KVA GS SERIES CHASSIS AIR EXHAUST FAN SEE TOP COVER SCREEN BELOW FOR DETAILS 2.25 AIR INTAKE (BOTH SIDES) REAR VIEW TERMINAL BLOCK SCREW SIZE #8-32 NOTES: CHASSIS SLIDES (BOTH SIDES) GENERAL DEVICES P/N: CTS-120 (OPTIONAL) 1. ALL DIMENSIONS ARE IN INCHES. 2. EXTERIOR ANSI# 61 GRAY SEMI-GLOSS. 3. HANDLES PROJECT 1.50 INCHES FROM PANEL SURFACE. 4. CHASSIS SLIDES OPTIONAL. NOVA ELECTRIC Leader in power conversion technology since 1966 MADE IN USA

66 61 GALAXY SERIES RUGGED PURE-SINEWAVE DC-AC INVERTERS VDC INPUT 120V OR 220V 1Ø 50 Hz, 60 Hz or 400 Hz APPLICATIONS The transformer isolated Galaxy Series Inverters are extremely rugged by design, and feature an optional advanced Internal Suppression Filter Network (ISFN) to suppress the significant transients usually associated with electric utility and military applications. The units are also extremely reliable, designed to provide many years of service in harsh shock, vibration, humidity, and EMI environments. Utilizing field proven technology, this family of rugged pure sinewave DC-AC Inverters is suitable for harsh environments and can be customized for unique applications including: q MILITARY SHELTERS q GROUND SUPPORT q MOBILE SYSTEMS q TACTICAL SYSTEMS q UTILITY APPLICATIONS q COMMUNICATIONS q MIL-STD-810 q MIL-STD-461 q UTILITY POWER For more information, please visit us at or us at novasales@theallpower.com

67 62 ELECTRICAL Input: VDC Output: specify 120 or 220VAC 1Ø (Three-Phase Output Optional) Frequency: Specify 50, 60, or 400Hz Voltage Regulation: ± 2% NL to FL Frequency Regulation: ± 0.5% NL to FL Harmonic Distortion: 5% THD Power Factor: 0.7 lead to 0.7 lag Efficiency at full load: 75-88% typical Overload: 125% for 5 minutes STANDARD INDICATORS Output Volt & Amp Meters Input Power On Lamp HIGH-RELIABILITY MTBF: 100,000 Hours MTBR: 30 Minutes (assuming qualified tech) ENVIRONMENTAL Operating Temp.: -20 to +50 C (extended range optional) Storage Temp. Range: -40 to +71 C Humidity: to 95% non-condensing Elevation: 15,000 Ft. (4,572m) operating; 40,000 Ft. (12,192m) non-operating Shock: 20g for 11mS half sinewave Audible Noise: Less than 55 dba at 5 ft. PROTECTIVE FEATURES Current Limit Short Circuit Protection Thermal Protection Semiconductor Protection ISFN (Optional) MODEL SELECTION OPTIONS Ruggedized to meet MIL-STD-810 shock,vibration and humidity ( R option) Wide temperature range -40 C to +71 C Special output voltages and frequencies Provision for 3 Phase connection with 2 more identical units MS Connectors or outlets Custom painting and marking Handles High inrush for motor start Transfer switch to alternate AC source Switchable 50/60 Hz output RS232 or SNMP Communication Output fault alarm (relay closure) MODEL INPUT VDC VAC FREQ. (Hz) CONTINUOUS POWER APPROX. WEIGHT (LB) SIZE (H x W x L) INCHES GH VA x x 7.15 GH1K KVA x x 7.15 GH2K KVA x x 8.00 GH3K KVA x x GH5K KVA x x GH6K KVA x x GH7.5K KVA x x GH10K KVA x x GH15K KVA x x GH20K KVA C/F x x GH25K KVA C/F x x GH30K KVA C/F x x GH35K KVA C/F x x MECHANICAL SPECIFICATIONS CONDUIT ACCESS PLATE W / NEOPRENE SEAL INVERTER HEATSINK W / NEOPRENE SEAL TYPICAL GH2K CHASSIS "INVERTER ON" INDICATOR LIGHT W / NEOPRENE SEAL NAME PLATE NOVA PLATE "NOVA LOGO" NOVA ELECTRIC Leader in power conversion technology since 1966 MADE IN USA

68 63 GALAXY SERIES RUGGED PURE-SINEWAVE DC-AC INVERTERS VDC INPUT 120V OR 220V 1Ø 50 Hz, 60 Hz or 400 Hz APPLICATIONS The transformer isolated Galaxy Series Inverters are extremely rugged by design, and feature an optional advanced Internal Suppression Filter Network (ISFN) to suppress the significant transients usually associated with heavy industrial and military applications. The units are also extremely reliable, designed to provide many years of service in harsh shock, vibration, humidity, and EMI environments. Utilizing field proven technology, this family of rugged pure sinewave DC-AC Inverters is suitable for harsh environments and can be customized for unique applications including: q SHELTERS q GROUND SUPPORT q ALUMINUM MILLS q TACTICAL SYSTEMS q STEEL MILLS q CRANE APPLICATIONS q MIL-STD-810 q MIL-STD-461 q DOD-STD-1399 q MIL-S-901 q MIL-STD-704 (OPTIONAL) For more information, please visit us at or us at novasales@theallpower.com

69 64 STANDARD FEATURES Pure Sinewave Output Internal Transient Supression Filter Network for input voltage transients High reliability, MTBF exceeds 100,000 hrs O.V, O.L, and O.T protected MTTR below 30 minutes Withstands high reactive load Tight voltage and frequency regulation Boards are conformal coated ENVIRONMENTAL Operating Temp.: -20 to +50 C Cooling: By internal DC brushless fan Vibration: Normal shipping and handling Shock: 20g for 11mS half sinewave Humidity: To 95% RH non-condensing EMI: Designed to meet FCC Part 15 Class A. Can meet MIL-STD-461 with additional filtering MODEL INPUT VDC VAC ELECTRICAL Input: 240 VDC (Extended range available) Output: See table Frequency: 50Hz, 60Hz, or 400Hz (±0.5%) Voltage Regulation: ± 1.5% NL to FL Frequency Regulation: ± 0.5% NL to FL Reactive Load: 0.75 lead to 0.75 lag Efficiency: Approximately 88% (depending on model) Overload: 125% for 5 minutes Distortion: 5% THD, 3% Single Harmonic Overload: 125% for 5 minutes Overload Protection Range: Automatic overload & short circuit protection Sync & Phase Lock Range: ±3Hz Typical Trasient Response: Approx. 1/4 cycle recovery to 95% of nominal MODEL SELECTION FREQ. (Hz) CONTINUOUS POWER APPROX. WEIGHT (LB) MECHANICAL SPECIFICATIONS OPTIONS Ruggedized to meet MIL-STD-810 shock,vibration and humidity ( R option) Wide temperature range -40 C to +71 C Special output voltages and frequencies Provision for 3 Phase connection with 2 more identical units MS Connectors or outlets Custom painting and marking Handles High inrush for motor start Transfer switch to alternate AC source Chassis slides (rack mount models only) Switchable 50/60 Hz output RS232 or SNMP Communication Output fault alarm (relay closure) APPROX. EFFICIENCY SIZE (H x W x L) INCHES GS VA 50 88% 5.25 x x GS1K KVA 95 88% 5.25 x x GS2K KVA % 5.25 x x GS3K KVA % 8.75 x x GS5K KVA % 8.75 x x TYPICAL 5U CHASSIS NOVA ELECTRIC Leader in power conversion technology since 1966 MADE IN USA

70 65 GALAXY SERIES RUGGED PURE-SINEWAVE DC-AC INVERTERS VDC INPUT 120V OR 220V 1Ø 50 Hz, 60 Hz or 400 Hz APPLICATIONS The transformer isolated Galaxy Series Inverters are extremely rugged by design, and feature an optional advanced Internal Suppression Filter Network (ISFN) to suppress the significant transients usually associated with heavy industrial and military applications. The units are also extremely reliable, designed to provide many years of service in harsh shock, vibration, humidity, and EMI environments. Utilizing field proven technology, this family of rugged pure sinewave DC-AC Inverters is suitable for harsh environments and can be customized for unique applications including: q SHELTERS q GROUND SUPPORT q ALUMINUM MILLS q TACTICAL SYSTEMS q STEEL MILLS q CRANE APPLICATIONS q MIL-STD-810 q MIL-STD-461 q DOD-STD-1399 q MIL-S-901 q MIL-STD-704 (OPTIONAL) For more information, please visit us at or us at novasales@theallpower.com

71 66 STANDARD FEATURES Pure Sinewave Output Internal Transient Supression Filter Network for input voltage transients High reliability, MTBF exceeds 100,000 hrs O.V, O.L, and O.T protected MTTR below 30 minutes Withstands high reactive load Tight voltage and frequency regulation Boards are conformal coated ENVIRONMENTAL Operating Temp.: -20 to +50 C Cooling: By internal DC brushless fan Vibration: Normal shipping and handling Shock: 20g for 11mS half sinewave Humidity: To 95% RH non-condensing EMI: Designed to meet FCC Part 15 Class A. Can meet MIL-STD-461 with additional filtering MODEL INPUT VDC VAC ELECTRICAL Input: 240VDC (Extended range available) Output: See table Frequency: 50Hz, 60Hz, or 400Hz (±0.5%) Voltage Regulation: ± 1.5% NL to FL Frequency Regulation: ± 0.5% NL to FL Reactive Load: 0.75 lead to 0.75 lag Efficiency: Approximately 88% (depending on model) Overload: 125% for 5 minutes Distortion: 5% THD, 3% Single Harmonic Overload: 125% for 5 minutes Overload Protection Range: Automatic overload & short circuit protection Sync & Phase Lock Range: ±3Hz Typical Trasient Response: Approx. 1/4 cycle recovery to 95% of nominal FREQ. (Hz) CONTINUOUS POWER APPROX. WEIGHT (LB) AVAILABLE OPTIONS 400 Hz Output High IP Protection for Intake / Exhaust fans (typically IP32) AUX DC Outputs Ruggedization against high shock, vibration and humidity MS connector mates and multiple output outlets Electromechanical transfer switch Custom Enclosures CAD Free Connectors Non-PVC wiring Output Volt & Amp meters Output frequency meters Elapsed time meter Shock mounts Floor mount feet APPROX. EFFICIENCY SIZE (H x W x L) INCHES GH VA 90 88% x x 7.15 GH1K KVA 95 88% x x 7.15 GH2K KVA % x x 8.00 GH3K KVA % x x GH5K KVA % x x GH7.5K KVA % x x GH10K KVA % x x GH15K KVA % x x GH20K KVA % x x GH25K KVA % x x GH30K KVA 900 C/F x x GH35K KVA 1100 C/F x x CONDUIT ACCESS PLATE W / NEOPRENE SEAL INVERTER HEATSINK W / NEOPRENE SEAL.72 MODEL SELECTION MECHANICAL SPECIFICATIONS TYPICAL GH2K CHASSIS "INVERTER ON" INDICATOR LIGHT W / NEOPRENE SEAL NAME PLATE NOVA PLATE "NOVA LOGO" NOVA ELECTRIC Leader in power conversion technology since 1966 MADE IN USA

72 67 GALAXY SERIES PURE-SINEWAVE DC-AC INVERTERS VDC INPUT 1Ø OR 3Ø AC 50 Hz, 60 Hz or 400 Hz APPLICATIONS The transformer isolated Galaxy Series Inverters are extremely rugged by design, and feature an optional advanced Internal Suppression Filter Network (ISFN) to suppress the significant transients usually associated with rail and military applications. The units are also extremely reliable, designed to provide many years of service in harsh shock, vibration, humidity, and EMI environments. Utilizing field proven technology, this family of rugged pure sinewave DC-AC Inverters is suitable for harsh environments and can be customized for unique applications including: q WORK TRAINS q TROLLEYS q SHOW TRAINS q SUBWAYS q LOCOMOTIVES q MILITARY For more information, please visit us at or us at novasales@theallpower.com

73 68 ELECTRICAL Input: VDC (Extended Available) Output: specify 120 or 220VAC 1Ø (Three-Phase Output Optional) Frequency: Specify 50, 60, or 400Hz Voltage Regulation: ± 1.5% NL to FL Frequency Regulation: ± 0.5% NL to FL Harmonic Distortion: 5% THD Power Factor: 0.7 lead to 0.7 lag Efficiency at full load: 90% typical Overload: 125% for 5 minutes HIGH RELIABILITY MTBF: 100,000 Hours MTBR: 30 Minutes (assuming qualified tech) STANDARD INDICATORS Input Power On Lamp PROTECTIVE FEATURES Current Limit Short Circuit Protection Thermal Protection Semiconductor Protection, and ISFN Input OV/UV Alarm and Monitor with Contact Closures ENVIRONMENTAL Operating Temp.: -20 to +50 C Storage Temp. Range: -40 to +71 C Humidity: to 95% non-condensing Elevation: 15,000 Ft. (4.572m) operating; 40,000 Ft. (12.192m) non-operating Shock: 20g for 11mS Audible Noise: Less than 55 dba at 5 ft. SINGLE PHASE MODEL SELECTION MODEL INPUT (VDC) (VAC) FREQ. (Hz) POWER SIZE (H x W x L) GH1K KVA x x 8.00 GH2K KVA x x 8.00 GH3K KVA x x GH5K KVA x x GH7.5K KVA x x GH10K KVA x x GH15K KVA x x GH20K KVA x x GH25K KVA x x GH30K KVA x x GH35K KVA x x THREE PHASE MODEL SELECTION MECHANICAL SPECIFICATIONS OPTIONS Ruggedized to meet MIL-STD-810 shock,vibration and humidity ( R option) Wide temperature range -40 C to +71 C Special output voltages and frequencies Provision for 3 Phase connection with 2 more identical units MS Connectors or outlets Custom painting and marking Handles High inrush for motor start Transfer switch to alternate AC source Switchable 50/60 Hz output RS232 or SNMP Communication Output fault alarm (relay closure) MODEL INPUT (VDC) (VAC) FREQ. (Hz) POWER SIZE (H x W x L) GS1.5K3/6-600(120/208) / KVA Consult Factory GS3K3/6-600(120/208) / KVA Consult Factory GS4.5K3/6-600(120/208) / KVA Consult Factory GH6K3/6-600(120/208) / KVA Consult Factory GH9K3/6-600(120/208) / KVA Consult Factory GH15K3/6-600(120/208) / KVA Consult Factory GH20K3/6-600(120/208) / KVA Consult Factory GH25K3/6-600(120/208) / KVA Consult Factory GH30K3/6-600(120/208) / KVA Consult Factory GH35K3/6-600(120/208) / KVA Consult Factory CONDUIT ACCESS PLATE W / NEOPRENE SEAL INVERTER HEATSINK W / NEOPRENE SEAL TYPICAL GH2K CABINET "INVERTER ON" INDICATOR LIGHT W / NEOPRENE SEAL NAME PLATE NOVA PLATE "NOVA LOGO" NOVA ELECTRIC Leader in power conversion technology since 1966 MADE IN USA

74 69 ULTRA-LIGHTWEIGHT RUGGED GALAXY SERIES DC-AC INVERTER COMPACT 3U CHASSIS 2-5KVA POWER 270VDC NOMINAL WIDE RANGE INPUT OPTIONAL SNMP COMMUNICATIONS APPLICATIONS The Lightweight Galaxy-Series DC-AC Inverters are high-reliability power sources specifically designed for demanding applications in high shock, vibration, humidity, and EMI environments in compliance to MIL-STD-461, MIL-S-901, MIL-STD-167, MIL-STD-810, MIL-STD-740, and DOD-STD These models utilize field-proven technology, offering maximum reliability for severe environment and high reliability applications such as: q SHELTERS q GROUND SUPPORT q TRANSIT CASES q TACTICAL SYSTEMS q HMMWVs q SHIPBOARD POWER q MIL-STD-810 q SERVERS q MOBILE SYSTEMS q MIL-STD-167 q MIL-S-901 q MIL-STD-461 For more information, please visit us at or us at novasales@theallpower.com

75 70 OPTIONS 400 Hz Output High IP Protection for front / rear panels AUX DC Outputs MS connector mates and multiple output outlets Chassis Slide Guides Electromechanical transfer switch Custom Enclosures CAD Free Connectors Non-PVC wiring Bulkhead mounting OPTIONAL INDICATORS Status (Red / Green) Inverter Off (Red) Logic Fault (Red) Over Temperature (Red) Load on Utility (Red) (optional with transfer switch) ELECTRICAL Input Voltage: 270 VDC Nominal, VDC Operating Range (other ranges available) Output Voltage: 120, 208, or 230 VAC (specify) Frequency: 50 / 60 / 400 Hz. Available Voltage Regulation: ± 2% NL to FL Frequency Regulation: ± 0.5% NL to FL Harmonic Distortion: 5% THD, 3% typical Input Power Factor: 0.95 or half-full load (except 3 phase input models) Efficiency at full load: full load typical Connections: MS Connector (mates optional) OPTIONAL REMOTE CONTACTS/COMMUNICATIONS SNMP V1.0 via CAT-5 Connector Major Alarm: Logic Fault, Overtemperature, Overload Minor Alarm: Utility Off RS 232 (Available-Optional) Via DB 9 Connector Alarm Contacts(Available-Optional) ENVIRONMENTAL UPS Operating Temp.: -20 to +55 C (Extended ranges optional - Consult factory) UPS Storage Temp. Range: -40 to +71 C Humidity: to 95% non-condensing Elevation: 15,000 Ft. (4,572m) operating; 40,000 ft. (12,192m) non-operating Shock: 20g for 11mS Audible Noise: Less than 55 dba at 5 ft. OPTIONAL PROTECTIVE FEATURES DC Input Circuit Breaker, AC Output Circuit Breaker, and Audible Alarm with Silence Switch NOMINAL DIMENSIONS 5.25 H x W x D MODEL SELECTION 120 VAC MODELS 220 VAC MODELS MODEL INPUT VDC VAC FREQ. (Hz) CONTINUOUS POWER APPROX. WEIGHT (LB) SIZE (H x W x L) INCHES MODEL INPUT VDC VAC FREQ. (Hz) CONTINUOUS POWER APPROX. WEIGHT (LB) SIZE (H x W x L) INCHES GL2K KVA x x GL3K KVA x x GL4K KVA x x GL5K KVA x x GL2K50-270(220) KVA x x GL3K50-270(220) KVA x x GL4K50-270(220) KVA x x GL5K50-270(220) KVA x x MECHANICAL SPECIFICATIONS NOVA ELECTRIC Leader in power conversion technology since 1966 MADE IN USA

76 71 GALAXY SERIES PURE-SINEWAVE DC-AC INVERTERS COMPACT BULKHEAD MOUNT CHASSIS 2-5KVA POWER 270VDC NOMINAL WIDE RANGE INPUT OPTIONAL SNMP COMMUNICATIONS APPLICATIONS Nova s Lightweight Galaxy-Series DC-AC Inverters are high-reliability power sources specifically designed for demanding applications in high shock, vibration, humidity, and EMI environments in compliance to MIL-STD-461, MIL-S-901, MIL-STD-167, MIL-STD-810, MIL-STD-740, and DOD-STD These models utilize field-proven technology, offering maximum reliability for severe environment and high reliability applications such as: q SHELTERS q GROUND SUPPORT q SERVERS q TACTICAL SYSTEMS q HMMWVs q SHIPBOARD POWER q MIL-STD-810 q SUBMARINES q MOBILE SYSTEMS q MIL-STD-167 q MIL-S-901 q MIL-STD-461 For more information, please visit us at or us at novasales@theallpower.com

77 72 OPTIONS 400 Hz Output High IP Protection for Intake / Exhaust fans (typically IP32) AUX DC Outputs Ruggedization against high shock, vibration and humidity MS connector mates and multiple output outlets Chassis Slide Guides Electromechanical transfer switch Custom Enclosures CAD Free Connectors Non-PVC wiring Rack mounting Output Volt & Amp meters Output frequency meters Elapsed time meter Shock mounts Floor mount feet 120 VAC MODELS NOMINAL DIMENSIONS 30H x 24 W x D OPTIONAL INDICATORS Status (Red / Green) Inverter Off (Red) Logic Fault (Red) Over Temperature (Red) Load on Utility (Red) Optional with transfer switch ELECTRICAL Input Voltage: 270 VDC Nominal, VDC Operating Range (other ranges available) Output Voltage: 120, 208, or 230 VAC (specify) Frequency: 50 / 60 / 400 Hz. Available Voltage Regulation: ± 2% NL to FL Frequency Regulation: ± 0.5% NL to FL Harmonic Distortion: 5% THD, 3% typical Input Power Factor: 0.95 or half-full load (except 3 phase input models) Efficiency at full load: full load typical Connections: MS Connector (mates optional) MODEL SELECTION OPTIONAL REMOTE CONTACTS/COMMUNICATIONS SNMP V1.0 via CAT-5 Connector Major Alarm: Logic Fault, Overtemperature, Overload Minor Alarm: Utility Off RS 232 (Available-Optional) Via DB 9 Connector Alarm Contacts(Available-Optional) ENVIRONMENTAL UPS Operating Temp.: -20 to +55 C (Extended ranges optional - Consult factory) UPS Storage Temp. Range: -40 to +71 C Humidity: to 95% non-condensing Elevation: 15,000 Ft. (4,572m) operating; 40,000 Ft. (12,192m) non-operating Shock: 20g for 11mS Audible Noise: Less than 55 dba at 5 ft. OPTIONAL PROTECTIVE FEATURES DC Input Circuit Breaker, AC Output Circuit Breaker, and Audible Alarm with Silence Switch 220 VAC MODELS MODEL INPUT VDC VAC FREQ. (Hz) CONTINUOUS POWER APPROX. WEIGHT (LB) MODEL INPUT VDC VAC FREQ. (Hz) CONTINUOUS POWER APPROX. WEIGHT (LB) GLH2K KVA 150 GLH3K KVA 150 GLH4K KVA 150 GLH5K KVA 150 GLH2K50-270(220) KVA 55 GLH3K50-270(220) KVA 57 GLH4K50-270(220) KVA 60 GLH5K50-270(220) KVA 60 MECHANICAL SPECIFICATIONS NOVA ELECTRIC Leader in power conversion technology since 1966 MADE IN USA

78 73 NGL SERIES RUGGED DC TO AC INVERTERS 1 KW (FRONT PANEL) 100 W (FRONT PANEL) 2 KW & 3 KW (FRONT PANEL) VDC INPUT 120V OR 230V 1Ø 50 Hz, 60 Hz or 400 Hz APPLICATIONS 3.5 KW FRONT PANEL The NGL modular inverters are intended for industrial or military applications wherever standard generator or utility-like power is needed at 50 Hz, 60 Hz or 400 Hz. These inverters are intended for running electronic loads such as computers, monitors, printers, telecom systems and radios from VDC nominal derived from batteries and field generators. They can also be used for properly scaled hand tools, motors and air conditioner units. These units can be further ruggedized against shock, vibration and humidity to meet tough military special applications. Utilizing field proven technology, this family of rugged pure sinewave DC-AC Inverters is suitable for harsh environments and can be optionally customized for unique sizes. Combining 3 inverters to form a 3 phase power system is optional. In this configuration, a 3 phase and neutral line is generated with precise synchronization. q MILITARY SHELTERS q GROUND SUPPORT q MOBILE SYSTEMS q TACTICAL SYSTEMS q SHIP APPLICATIONS q COMMUNICATIONS For more information, please visit us at or us at novasales@theallpower.com

79 74 FEATURES Crystal Controlled Frequency Compact and light weight, yet rugged and vehicle rated % efficient. Tightly regulated output voltage and freq. Able to supply inrush current. Factory set to 50 Hz, 60 Hz or 400Hz output. Capable of driving highly reactive loads such as motors and AC. Capable of driving highly capacitive loads such as non PFC switching power supplies. Very low harmonic distortion, THD<3%. Suitable for vehicle mounting. Fan cooled with air filter. Can be wired to form 3Ø output. ELECTRICAL Input Voltage: 12, 24, 48, 120, 155 or 270 VDC Output Voltage 120V model: 100/110/120 VAC Output Voltage 230V model: 220/230/240 VAC Output Frequency: 50 Hz,60 Hz or 400 Hz Surge Rating: 120% 5 minutes Efficiency 120V model (full load): 86% Efficiency 230V model (full load): 88% Output Waveform Sinewave: <3% THD Output Regulation: ± 2.5% MTBF: over 100,000 hours per field data MTTR: 30 minutes PROTECTIVE FEATURES Overload Overvoltage Overtemperature ENVIRONMENTAL Operating Temperature: -20 C to +50 C Storage Temperature: -40 C to + 71 C Shock: 20g / 11mS per MIL-STD-810 Vibration: per MIL-STD-810 Surface Vehicle or MIL-STD-167 Shipboard Humidity: per MIL-STD-810 to 95% non condensing EMI: per MIL-STD-461 (May require additional external EMI filter.) POPULAR OPTIONS MS Connector and Mates Rack Mount Enclosure Mounting Bracket Internal Electromechanical Transfer Switch Partial Single Phase Model Selection - 100W - 3KW in 50, 60, and 400 Hz MODEL KW / VA FREQ. (Hz) See XX in Model NOMINAL INPUT (VDC) See YY in Model VOLTAGE (VAC) See ZZZ in Model WEIGHT (Lb. / Kg.) DIMENSIONS ( H x W x L - Inch & [mm] ) NGL10XX-YY-ZZZ NGL1KXX-YY-ZZZ NGL2KXX-YY-ZZZ NGL3KXX-YY-ZZZ 100W / 120VA 1KW / 1.2KVA 2KW / 2.5KVA 3KW / 3.5KVA Select: Specialty frequencies also available. Consult Factory. Select: Specialty inputs also available. Consult Factory. Select: Specialty inputs also available. Consult Factory. 2.4 / / / / x 4.50 x 7.75 [ 68 x 114 x 197 ] [ 66 x 127 x 254 ] 5.00 x 8.00 x [ 127 x 203 x 318 ] 5.00 x 8.00 x [ 127 x 203 x 318 ] NGL3.5KXX-YY-ZZZ 3.5KW / 4.5KVA 16.3 / x 8.00 x [ 127 x 203 x 375 ] Partial Three Phase Model Selection - 300W - 9KW in 50, 60, and 400 Hz MODEL KW / VA FREQ. (Hz) See XX in Model NOMINAL INPUT (VDC) See YY in Model VOLTAGE (VAC) See ZZZ in Model WEIGHT (Lb. / Kg.) DIMENSIONS ( H x W x L - Inch & [mm] ) NGL303/XX-YY(ZZZ/ZZZ) NGL3K3/XX-YY(ZZZ/ZZZ) NGL6K3/XX-YY(ZZZ/ZZZ) NGL9K3/XX-YY(ZZZ/ZZZ) 300W / 360VA 3KW / 3.6KVA 6KW / 7.5KVA 9KW / 13.5KVA Select: Specialty frequencies also available. Consult Factory. Select: Specialty inputs also available. Consult Factory. Select: 115/ / / / /415 Specialty inputs also available. Consult Factory. 7.2 / / / / Ø systems are available in individual freestanding single-phase modules, 19 rack mount, wall mount, and many other packaging configurations. Please consult factory for details on sizes available. MODEL SELECTION INPUT VOLTAGE SELECTION NGL { { { { POWER IN VA 2. FREQUENCY 3. INPUT VOLTAGE SELECTION 4. VOLTAGE SELECTION NOMINAL RANGE NOVA ELECTRIC Leader in power conversion technology since 1966 MADE IN USA

80 75 NGL SERIES RUGGED DC TO AC INVERTERS OUTLINE DRAWINGS 100 W VA 1 KW K For more information, please visit us at or us at novasales@theallpower.com

81 76 OUTLINE DRAWINGS 2 KW 3 KW KW 3 KW 3.5 KW K NOVA ELECTRIC Leader in power conversion technology since 1966 MADE IN USA

82 77 JUPITER SERIES PURE-SINEWAVE DC-AC INVERTERS APPLICATIONS Nova s Jupiter-Series DC-AC Inverters are high-reliability pure sinewave power sources specifically designed for demanding commercial, heavy industrial, and military applications. They can be built to meet MIL-STD-810, MIL-S-901, MIL-STD-461, and other standards optionally. These models utilize the most durable components, offering maximum field-proven reliability for severe environment and high reliability applications such as utility stations, shelters, shore power, and communications. q Military programs, vehicular, shipboard q AC Power from battery q Communications q Shelters q Utility Applications q Emergency Lighting FEATURES Complete input to output Galvanic isolation. Almost silent high frequency operation Push button starting and stopping Diagnostic panel with LCD and LED display Soft start on inverter Overload and short circuit protection Optional solid state transfer switch built in Optional maintenance bypass switch built in Optional DC input circuit breaker Remote isolated dry relay contacts Available options to meet military specs including MIL-STD-461, MIL-STD-167, MIL-STD-810 All electronics are built in modular front access and front removable sub assemblies for easy service and maintenance For more information, please visit us at or us at novasales@theallpower.com

83 78 The Inverter includes an RS232 communication option called UPSCOM. This is an RS232 connection to a PC that can monitor the information related to the inverter output and any abnormal conditions that have occurred in real time. Standard commercially available software is provided. The RS232 Feature is included at no additional charge. FRONT PANEL LCD DISPLAY AND LED INDICATORS - These will report all Inverter parameters, including input and output voltages, currents, frequency, DC voltage and many other functions. LCD DISPLAY - Real time status, data, and historical events are displayed via the LCD display. The Inverter parameters, real time clock, and buzzer alarm also can be set through this LCD. The LCD is backlit by LEDs for easy visuals. STATUS LEDs - A series of LEDs representing all the important status information of the Inverter provide information to the user. These LEDs are especially important when abnormal conditions occur. Since these LEDs are located behind the transparent window, the user can see them clearly without opening the door. LED descriptions are as follows: INVERTER ON Inverter is running normally. INVERTER SS Inverter static switch is on while the reserve static switch is opened (off). SHORT CIRCUIT Inverter output is in short circuit state. FUSE / OVERTEMP SD Inverter has shut down due to either open fuse open or overtemperature. INVERTER FAIL SHUT DOWN Inverter has shut down due to low inverter AC output. BYPASS ON SHUT DOWN Inverter shut down due closed bypass breaker (while inverter running). HIGH DC SHUT DOWN Inverter shut down due to high DC bus. OVERLOAD SHUT DOWN Inverter shut down due to overload of the inverter for a period greater than the inverter can accept. The inverter will start after 7 seconds. 70% LOAD load connected to the output is over 70% of the inverter rating. 110% LOAD load connected to the output is over 110% of the inverter rating. 125% LOAD load connected to the output is over 125% of the inverter rating. 150% LOAD load connected to the output is over 150% of the inverter rating. RESERVE AC FAIL reserve AC magnitude is out of range. RESERVE FREQ FAIL reserve frequency is out of range. BATTERY LOW - DC bus (or battery) is lower than specified range. Low battery shut down will occur soon. BATTERY LOW SHUT DOWN Inverter shut down due to DC bus (or battery) lower than the acceptable DC voltage of the inverter. COMMUNICATIONS OPTIONS Some popular communications options available at additional cost include the following: UPSCAN: This is a hand held remote display and control module with LCD and LED display that can monitor up to 99 inverter units via RS-485 at a remote distance of up to 3,000 feet. NETAGENT: This provides capability to monitor the inverter over the internet. It includes the appropriate additional SNMP card and microprocessor. The software required is provided separately. HIGH DC DC voltage over the acceptable DC voltage of the inverter. EMERGENCY STOP Inverter shutdown activated by emergency stop switch. DATA LINE Blinks when data is transmitted to or received from the communication port. MONITORING FEATURES WARNING LEDs When abnormal condition occurs, these LEDs will light to warn the user of the cause of the fault condition. Therefore all these LEDs are off under normal condition. These LEDs are: RECT AC FAIL Rectifier AC input is abnormal either due to AC magnitude out of the range or phase rotation error; rectifier shut down. RESERVE FAIL Reserve AC input is abnormal either due to AC magnitude out of range or frequency out of range. FUSE/TEMP - Either inverter fuse is open or over temperature has occurred. OVERLOAD Output is overloaded by over 110%, 125% or 150% HIGH DC This LED will light as long as the DC voltage is over 430VDC. BAT LOW This LED will light when the DC voltage is lower than 320VDC. BAT LOW STOP This LED will light when the DC voltage is lower than 295VDC, inverter on is inhibited. FAULT The inverter is off due to abnormal conditions such as overload, short circuit, high DC, fuse over temperature, bypass breaker on emergency stop. AUDIBLE ALARM The audible alarm will beep under one of the following conditions: INVERTER IS OVERLOADED : 110% beep once every 3 seconds 125% beep once every second 150% beep twice every second INVERTER IS SHORT CIRCUITED Beeps continuously FUSE OPEN Beeps continuously HEAT SINK OVER TEMPERATURE Beeps continuously HIGH DC SHUTDOWN Beeps continuously BYPASS ON STOP Beeps continuously EMERGENCY ON STOP Beeps continuously. The buzzer will also beep once every time the inverter is switched on or off to acknowledge to the user that his key entry is valid and accepted. OTHER OPTIONS DC INPUT BREAKER OPTION The optional DC Input breaker disconnect is offered to provide protection for the input. SHOCK MOUNT OPTION The cabinet can be shock mounted using optional rubber or coil type isolators. This will enable the unit to withstand shock levels as specified in MIL-S-901. RUGGEDIZING OPTION This option will add conformal coating and other additional internal structural members to allow the unit to meet many portions of MIL-STD-810 including shock, vibration, and humidity. TURN ON SERVICE OPTION We offer a turn on service that will ensure the Inverter has been properly installed and the full warranty is in effect (failures caused by incorrect installation are not covered by the warranty.) If this option is selected, the customer will also automatically receive an additional 3 months added to the warranty at no additional charge. SPARE PARTS KIT OPTION We offer a spare parts package that includes one of each board, spare fuses, spare semiconductors, and spare fans. These spare part kits are priced lower when ordered with the initial order than if they are ordered later on. DRIP SHIELD OPTIONS This option offers protection against falling or dripping liquids. CUSTOMIZED EPO This feature can be customized to trip off current breakers or perform other inhibits depending customer needs. NOVA ELECTRIC Leader in power conversion technology since 1966 MADE IN USA

84 79 JUPITER SERIES PURE-SINEWAVE DC-AC INVERTERS SPECIFICATION FOR JUPITER 120 VDC 1Ø OR 3Ø INVERTER SERIES INVERTER Input Voltage Range DC INPUT/ 1Ø OR 3Ø VDC (Extended Ranges Available) STANDARD PRODUCT LISTING VDC INPUT 60 Hz - 1Ø MODELS VAC FREQ. CONTINUOUS POWER WEIGHT (Lbs.) SIZE (H x W x L ) J10K Hz 10 KVA / 8 KW x 22 x 31.5 Output Voltage (VAC) Wave Form Output Power Factor Frequency Lock Range 3-Phase Models Please Specify 120/ / / / / delta 220 delta 240 delta 380 delta 480 delta OR Single Phase Models Please Specify 120 VAC 220 VAC 240 VAC 480 VAC Pure Sinewave 0.7 lead to 0.7 lag ± 5% (alternate ranges offered on special order) J15K Hz 15 KVA / 12 KW x 22 x 31.5 J20K Hz 20 KVA / 16 KW x 22 x 31.5 J30K Hz 30 KVA / 24 KW x 43.5 x 31.5 J40K Hz 40 KVA / 32 KW x 43.5 x 31.5 J50K Hz 50 KVA / 40 KW x 43.5 x 31.5 J60K Hz 60 KVA / 48 KW x 87 x 31.5 J80K Hz 80 KVA / 64 KW x 87 x 31.5 J100K Hz 100 KVA / 80 KW x 87 x 31.5 Output Frequency (Free Running) Phase Shift Under 100% Unbalanced Load THD (Linear Load) Overload Please Specify: 50 Hz or 60 Hz or 400 Hz (crystal controlled) <0.5% (3-Phase Models) 2% Typical 3% Max <110% Continuous % 15 minutes % 10 minutes >150% 1 minute Efficiency (100% Load) 89-90% Static Switch Voltage Range Mains <-> Inverter Optional Same as AC output ~Different voltages are available upon request~ 0 ms (True Online) Audible Noise >65dBA (at 1m) Temperature Humidity Altitude EN ,-2 Short Circuit Protection -10 C to +50 C (Extended ranges available) 0%-95% (Non-condensing) Up to 1500 m Above Sea Level Lighting/EMC Filter MOV/Input & Output (FCC CLASS A) Galvanic Isolation LED, LCD, Audible Alarm Remote Control/ Communication Interface Yes Yes Input / Output Galvanically Isolated Yes Monitoring 1~90 Units simultaneously/ Dry contact, RS-232, RS-485 (Optional) 50 Hz - 1Ø MODELS VAC FREQ. CONTINUOUS POWER WEIGHT (Lbs.) SIZE (H x W x L ) J10K50-120(220) Hz 10 KVA / 8 KW x 22 x 31.5 J15K50-120(220) Hz 15 KVA / 12 KW x 22 x 31.5 J20K50-120(220) Hz 20 KVA / 16 KW x 22 x 31.5 J30K50-120(220) Hz 30 KVA / 24 KW x 43.5 x 31.5 J40K50-120(220) Hz 40 KVA / 32 KW x 43.5 x 31.5 J50K50-120(220) Hz 50 KVA / 40 KW x 43.5 x 31.5 J60K50-120(220) Hz 60 KVA / 48 KW x 87 x 31.5 J80K50-120(220) Hz 80 KVA / 64 KW x 87 x 31.5 J100K50-120(220) Hz 100 KVA / 80 KW x 87 x Hz - 1Ø MODELS VAC FREQ. CONTINUOUS POWER WEIGHT (Lbs.) SIZE (H x W x L ) J10K Hz 10 KVA / 8 KW x 22 x 31.5 J15K Hz 15 KVA / 12 KW x 22 x 31.5 J20K Hz 20 KVA / 16 KW x 22 x 31.5 J30K Hz 30 KVA / 24 KW x 43.5 x 31.5 J40K Hz 40 KVA / 32 KW x 43.5 x 31.5 J50K Hz 50 KVA / 40 KW x 43.5 x 31.5 J60K Hz 60 KVA / 48 KW x 87 x 31.5 J80K Hz 80 KVA / 64 KW x 87 x 31.5 J100K Hz 100 KVA / 80 KW x 87 x Ø MODELS VAC FREQ. CONTINUOUS POWER WEIGHT (Lbs.) SIZE (H x W x L ) J10K3/6-120(120/208) 120/ Hz 10 KVA / 8 KW x 22 x 31.5 J10K3/5-120(220/380) 220/ Hz 10 KVA / 8 KW x 22 x 31.5 J10K3/4-120(115/200) 115/ Hz 10 KVA / 8 KW x 22 x 31.5 J20K3/6-120(120/208) 120/ Hz 20 KVA / 16 KW x 22 x 31.5 J20K3/5-120(220/380) 220/ Hz 20 KVA / 16 KW x 22 x 31.5 J20K3/4-120(115/200) 115/ Hz 20 KVA / 16 KW x 22 x 31.5 J30K3/6-120(120/208) 120/ Hz 30 KVA / 24 KW x 43.5 x 31.5 J30K3/5-120(220/380) 220/ Hz 30 KVA / 24 KW x 43.5 x 31.5 J30K3/4-120(115/200) 115/ Hz 30 KVA / 24 KW x 43.5 x 31.5 J40K3/6-120(120/208) 120/ Hz 40 KVA / 32 KW x 43.5 x 31.5 J40K3/5-120(220/380) 220/ Hz 40 KVA / 32 KW x 43.5 x Ø MODELS VAC FREQ. CONTINUOUS POWER WEIGHT (Lbs.) SIZE (H x W x L ) J50K3/6-120(120/208) 120/ Hz 50 KVA / 40 KW x 43.5 x 31.5 J50K3/5-120(220/380) 220/ Hz 50 KVA / 40 KW x 43.5 x 31.5 J50K3/4-120(115/200) 115/ Hz 50 KVA / 40 KW x 43.5 x 31.5 J60K3/6-120(120/208) 120/ Hz 60 KVA / 48 KW x 87 x 31.5 J60K3/5-120(220/380) 220/ Hz 60 KVA / 48 KW x 87 x 31.5 J60K3/4-120(115/200) 115/ Hz 60 KVA / 48 KW x 87 x 31.5 J80K3/6-120(120/208) 120/ Hz 80 KVA / 64 KW x 87 x 31.5 J80K3/5-120(220/380) 220/ Hz 80 KVA / 64 KW x 87 x 31.5 J80K3/4-120(115/200) 115/ Hz 80 KVA / 64 KW x 87 x 31.5 J100K3/6-120(120/208) 120/ Hz 100 KVA / 80 KW x 87 x 31.5 J100K3/5-120(220/380) 220/ Hz 100 KVA / 80 KW x 87 x 31.5 J40K3/4-120(115/200) 115/ Hz 40 KVA / 32 KW x 43.5 x 31.5 J100K3/4-120(115/200) 115/ Hz 100 KVA / 80 KW x 87 x 31.5 * For Input Circuit Breaker, add B1 suffix to part number For Solid State Transfer Switch, add Y11 suffix to part number For more information, please visit us at or us at novasales@theallpower.com

85 80 SPECIFICATION FOR JUPITER 240 VDC 1Ø OR 3Ø INVERTER SERIES INVERTER Input Voltage Range Output Voltage (VAC) Wave Form Output Power Factor Frequency Lock Range Output Frequency (Free Running) Phase Shift Under 100% Unbalanced Load THD (Linear Load) Overload DC INPUT/ 1Ø OR 3Ø VDC (Extended Ranges Available) 3-Phase Models Please Specify 120/ / / / / delta 220 delta 240 delta 380 delta 480 delta OR Single Phase Models Please Specify 120 VAC 220 VAC 240 VAC 480 VAC Pure Sinewave 0.7 lead to 0.7 lag ± 5% (alternate ranges offered on special order) Please Specify: 50 Hz or 60 Hz or 400 Hz (crystal controlled) <0.5% (3-Phase Models) 2% Typical 3% Max <110% Continuous % 15 minutes % 10 minutes >150% 1 minute Efficiency (100% Load) 90-91% Static Switch Voltage Range Mains <-> Inverter Optional Same as AC output ~Different voltages are available upon request~ 0 ms (True Online) Audible Noise >65dBA (at 1m) >67dBA (at 1m) Temperature Humidity Altitude EN ,-2 Short Circuit Protection -10 C to +50 C (Extended ranges available) 0%-95% (Non-condensing) Up to 1500 m Above Sea Level Lighting/EMC Filter MOV/Input & Output (FCC CLASS A) Galvanic Isolation LED, LCD, Audible Alarm Remote Control/ Communication Interface Yes Yes Input / Output Galvanically Isolated Yes Monitoring 1~90 Units simultaneously/ Dry contact, RS-232, RS-485 (Optional) STANDARD PRODUCT LISTING VDC INPUT 60 Hz - 1Ø MODELS VAC FREQ. CONTINUOUS POWER WEIGHT (Lbs.) SIZE (H x W x L ) J10K Hz 10 KVA / 8 KW x 22 x 31.5 J20K Hz 20 KVA / 16 KW x 22 x 31.5 J30K Hz 30 KVA / 24 KW x 22 x 31.5 J40K Hz 40 KVA / 32 KW x 22 x 31.5 J50K Hz 50 KVA / 40 KW x 43.5 x 31.5 J60K Hz 60 KVA / 48 KW x 43.5 x 31.5 J80K Hz 80 KVA / 64 KW x 87 x 31.5 J100K Hz 100 KVA / 80 KW x 87 x 31.5 J120K Hz 120 KVA / 96 KW x 87 x 31.5 J160K Hz 160 KVA / 128 KW x 87 x 31.5 J200K Hz 200 KVA / 160 KW x 87 x Hz - 1Ø MODELS VAC FREQ. CONTINUOUS POWER WEIGHT (Lbs.) SIZE (H x W x L ) J10K50-240(220) Hz 10 KVA / 8 KW x 22 x 31.5 J20K50-240(220) Hz 20 KVA / 16 KW x 22 x 31.5 J30K50-240(220) Hz 30 KVA / 24 KW x 22 x 31.5 J40K50-240(220) Hz 40 KVA / 32 KW x 22 x 31.5 J50K50-240(220) Hz 50 KVA / 40 KW x 43.5 x 31.5 J60K50-240(220) Hz 60 KVA / 48 KW x 43.5 x 31.5 J80K50-240(220) Hz 80 KVA / 64 KW x 43.5 x 31.5 J100K50-240(220) Hz 100 KVA / 80 KW x 43.5 x 31.5 J120K50-240(220) Hz 120 KVA / 96 KW x 87 x 31.5 J160K50-240(220) Hz 160 KVA / 128 KW x 87 x 31.5 J200K50-240(220) Hz 200 KVA / 160 KW x 87 x Hz - 1Ø MODELS VAC FREQ. CONTINUOUS POWER WEIGHT (Lbs.) SIZE (H x W x L ) J10K Hz 10 KVA / 8 KW x 22 x 31.5 J20K Hz 20 KVA / 16 KW x 22 x 31.5 J30K Hz 30 KVA / 24 KW x 22 x 31.5 J40K Hz 40 KVA / 32 KW x 22 x 31.5 J50K Hz 50 KVA / 40 KW x 43.5 x 31.5 J60K Hz 60 KVA / 48 KW x 43.5 x 31.5 J80K Hz 80 KVA / 64 KW x 43.5 x 31.5 J100K Hz 100 KVA / 80 KW x 43.5 x 31.5 J120K Hz 120 KVA / 96 KW x 87 x Ø MODELS VAC FREQ. CONTINUOUS POWER WEIGHT (Lbs.) SIZE (H x W x L ) J160K Hz 160 KVA / 128 KW x 87 x 31.5 J200K Hz 200 KVA / 160 KW x 87 x 31.5 J10K3/6-240(120/208) 120/ Hz 10 KVA / 8 KW x 22 x 31.5 J10K3/5-240(220/380) 220/ Hz 10 KVA / 8 KW x 22 x Ø MODELS VAC FREQ. CONTINUOUS POWER WEIGHT (Lbs.) SIZE (H x W x L ) J20K3/6-240(120/208) 120/ Hz 20 KVA / 16 KW x 22 x 31.5 J20K3/5-240(220/380) 220/ Hz 20 KVA / 16 KW x 22 x 31.5 J30K3/6-240(120/208) 120/ Hz 30 KVA / 24 KW x 22 x 31.5 J30K3/5-240(220/380) 220/ Hz 30 KVA / 24 KW x 22 x 31.5 J40K3/6-240(120/208) 120/ Hz 40 KVA / 32 KW x 22 x 31.5 J40K3/5-240(220/380) 220/ Hz 40 KVA / 32 KW x 22 x 31.5 J50K3/6-240(120/208) 120/ Hz 50 KVA / 40 KW x 44 x 31.5 J50K3/5-240(220/380) 220/ Hz 50 KVA / 40 KW x 44 x 31.5 J60K3/6-240(120/208) 120/ Hz 60 KVA / 48 KW x 43.5 x 31.5 J60K3/5-240(220/380) 220/ Hz 60 KVA / 48 KW x 43.5 x 31.5 J80K3/6-240(120/208) 120/ Hz 80 KVA / 64 KW x 43.5 x 31.5 J80K3/5-240(220/380) 220/ Hz 80 KVA / 64 KW x 43.5 x 31.5 J100K3/6-240(120/208) 120/ Hz 100 KVA / 80 KW x 43.5 x 31.5 J100K3/5-240(220/380) 220/ Hz 100 KVA / 80 KW x 43.5 x 31.5 J120K3/6-240(120/208) 120/ Hz 120 KVA / 96 KW x 87 x 31.5 J120K3/5-240(220/380) 220/ Hz 120 KVA / 96 KW x 87 x 31.5 J160K3/6-240(120/208) 120/ Hz 160 KVA / 128 KW x 87 x 31.5 J160K3/5-240(220/380) 220/ Hz 160 KVA / 128 KW x 87 x 31.5 J200K3/6-240(120/208) 120/ Hz 200 KVA / 160 KW x 87 x 31.5 J200K3/5-240(220/380) 220/ Hz 200 KVA / 160 KW x 87 x 31.5 NOVA ELECTRIC Leader in power conversion technology since 1966 MADE IN USA

86 81 JUPITER SERIES PURE-SINEWAVE DC-AC INVERTERS SPECIFICATION FOR JUPITER 350 VDC 1Ø OR 3Ø INVERTER SERIES INVERTER Input Voltage Range Output Voltage (VAC) Wave Form Output Power Factor Frequency Lock Range Output Frequency (Free Running) Phase Shift Under 100% Unbalanced Load THD (Linear Load) Overload DC INPUT/ 1Ø OR 3Ø VDC (Extended Ranges Available) 3-Phase Models Please Specify 120/ / / / / delta 220 delta 240 delta 380 delta 480 delta OR Single Phase Models Please Specify 120 VAC 220 VAC 240 VAC 480 VAC Pure Sinewave 0.7 lead to 0.7 lag ± 5% (alternate ranges offered on special order) Please Specify: 50 Hz or 60 Hz or 400 Hz (crystal controlled) <0.5% (3-Phase Models) 2% Typical 3% Max <110% Continuous % 15 minutes % 10 minutes >150% 1 minute Efficiency (100% Load) 90-91% Static Switch Voltage Range Mains <-> Inverter Optional Same as AC output ~Different voltages are available upon request~ 0 ms (True Online) Audible Noise >65dBA (at 1m) >67dBA (at 1m) Temperature Humidity Altitude EN ,-2 Short Circuit Protection -10 C to +50 C (Extended ranges available) 0%-95% (Non-condensing) Up to 1500 m Above Sea Level Lighting/EMC Filter MOV/Input & Output (FCC CLASS A) Galvanic Isolation LED, LCD, Audible Alarm Remote Control/ Communication Interface Yes Yes Input / Output Galvanically Isolated Yes Monitoring 1~90 Units simultaneously/ Dry contact, RS-232, RS-485 (Optional) STANDARD PRODUCT LISTING VDC INPUT 60 Hz - 1Ø MODELS VAC FREQ. CONTINUOUS POWER WEIGHT (Lbs.) SIZE (H x W x L ) J10K Hz 10 KVA / 8 KW x 22 x 31.5 J20K Hz 20 KVA / 16 KW x 22 x 31.5 J30K Hz 30 KVA / 24 KW x 22 x 31.5 J40K Hz 40 KVA / 32 KW x 22 x 31.5 J50K Hz 50 KVA / 40 KW x 43.5 x 31.5 J60K Hz 60 KVA / 48 KW x 43.5 x 31.5 J80K Hz 80 KVA / 64 KW x 87 x 31.5 J100K Hz 100 KVA / 80 KW x 87 x 31.5 J120K Hz 120 KVA / 96 KW x 87 x 31.5 J160K Hz 160 KVA / 128 KW x 87 x 31.5 J200K Hz 200 KVA / 160 KW x 87 x Hz - 1Ø MODELS VAC FREQ. CONTINUOUS POWER WEIGHT (Lbs.) SIZE (H x W x L ) J10K50-350(220) Hz 10 KVA / 8 KW x 22 x 31.5 J20K50-350(220) Hz 20 KVA / 16 KW x 22 x 31.5 J30K50-350(220) Hz 30 KVA / 24 KW x 22 x 31.5 J40K50-350(220) Hz 40 KVA / 32 KW x 22 x 31.5 J50K50-350(220) Hz 50 KVA / 40 KW x 43.5 x 31.5 J60K50-350(220) Hz 60 KVA / 48 KW x 43.5 x 31.5 J80K50-350(220) Hz 80 KVA / 64 KW x 43.5 x 31.5 J100K50-350(220) Hz 100 KVA / 80 KW x 43.5 x 31.5 J120K50-350(220) Hz 120 KVA / 96 KW x 87 x 31.5 J160K50-350(220) Hz 160 KVA / 128 KW x 87 x 31.5 J200K50-350(220) Hz 200 KVA / 160 KW x 87 x Hz - 1Ø MODELS VAC FREQ. CONTINUOUS POWER WEIGHT (Lbs.) SIZE (H x W x L ) J10K Hz 10 KVA / 8 KW x 22 x 31.5 J20K Hz 20 KVA / 16 KW x 22 x 31.5 J30K Hz 30 KVA / 24 KW x 22 x 31.5 J40K Hz 40 KVA / 32 KW x 22 x 31.5 J50K Hz 50 KVA / 40 KW x 43.5 x 31.5 J60K Hz 60 KVA / 48 KW x 43.5 x 31.5 J80K Hz 80 KVA / 64 KW x 43.5 x 31.5 J100K Hz 100 KVA / 80 KW x 43.5 x 31.5 J120K Hz 120 KVA / 96 KW x 87 x Ø MODELS VAC FREQ. CONTINUOUS POWER WEIGHT (Lbs.) SIZE (H x W x L ) J160K Hz 160 KVA / 128 KW x 87 x 31.5 J200K Hz 200 KVA / 160 KW x 87 x 31.5 J10K3/6-350(120/208) 120/ Hz 10 KVA / 8 KW x 22 x 31.5 J10K3/5-350(220/380) 220/ Hz 10 KVA / 8 KW x 22 x Ø MODELS VAC FREQ. CONTINUOUS POWER WEIGHT (Lbs.) SIZE (H x W x L ) J20K3/6-350(120/208) 120/ Hz 20 KVA / 16 KW x 22 x 31.5 J20K3/5-350(220/380) 220/ Hz 20 KVA / 16 KW x 22 x 31.5 J30K3/6-350(120/208) 120/ Hz 30 KVA / 24 KW x 22 x 31.5 J30K3/5-350(220/380) 220/ Hz 30 KVA / 24 KW x 22 x 31.5 J40K3/6-350(120/208) 120/ Hz 40 KVA / 32 KW x 22 x 31.5 J40K3/5-350(220/380) 220/ Hz 40 KVA / 32 KW x 22 x 31.5 J50K3/6-350(120/208) 120/ Hz 50 KVA / 40 KW x 44 x 31.5 J50K3/5-350(220/380) 220/ Hz 50 KVA / 40 KW x 44 x 31.5 J60K3/6-350(120/208) 120/ Hz 60 KVA / 48 KW x 43.5 x 31.5 J80K3/6-350(120/208) 120/ Hz 80 KVA / 64 KW x 43.5 x 31.5 J80K3/5-350(220/380) 220/ Hz 80 KVA / 64 KW x 43.5 x 31.5 J100K3/6-350(120/208) 120/ Hz 100 KVA / 80 KW x 43.5 x 31.5 J100K3/5-350(220/380) 220/ Hz 100 KVA / 80 KW x 43.5 x 31.5 J120K3/6-350(120/208) 120/ Hz 120 KVA / 96 KW x 87 x 31.5 J120K3/5-350(220/380) 220/ Hz 120 KVA / 96 KW x 87 x 31.5 J160K3/6-350(120/208) 120/ Hz 160 KVA / 128 KW x 87 x 31.5 J160K3/5-350(220/380) 220/ Hz 160 KVA / 128 KW x 87 x 31.5 J200K3/6-350(120/208) 120/ Hz 200 KVA / 160 KW x 87 x 31.5 J60K3/5-350(220/380) 220/ Hz 60 KVA / 48 KW x 43.5 x 31.5 J200K3/5-350(220/380) 220/ Hz 200 KVA / 160 KW x 87 x 31.5 * For Input Circuit Breaker, add B1 suffix to part number For Solid State Transfer Switch, add Y11 suffix to part number For more information, please visit us at or us at novasales@theallpower.com

87 82 TYPICAL DIMENSION DRAWINGS (22 WIDE) NOVA ELECTRIC Leader in power conversion technology since 1966 MADE IN USA

88 83 JUPITER SERIES PURE-SINEWAVE DC-AC INVERTERS TYPICAL DIMENSION DRAWINGS (43 WIDE) For more information, please visit us at or us at

89 84 TYPICAL DIMENSION DRAWINGS (87 WIDE) NOVA ELECTRIC Leader in power conversion technology since 1966 MADE IN USA

90 85 CGL300W SERIES PURE-SINEWAVE DC-AC INVERTERS 300W / 350VA 12 OR 24 VDC 120V 50/60 Hz OR 220 V 50/60 Hz APPLICATIONS Nova Electric s CGL-Series inverters are intended for commercial and industrial applications wherever pure sinewave power is needed at 50 or 60 Hz. These inverters are ideal for running electronic loads such as computers, monitors, printers, telecom systems, radios, fluorescent lamps from batteries, field generators, and solar electro-voltaic panels. They can also drive hand drills, motors and small compressors please consult the factory for proper sizing. These CGL models can also be optionally ruggedized against shock, vibration, and humidity for military applications including vehicle mounted, shipboard, submarine, aircraft, and ground fixed shelters. q COMPUTERS q SAIL BOATS q APPLIANCES q PRINTERS q PHOTO VOLTAIC q INSTRUMENTS For more information, please visit us at or us at novasales@theallpower.com

91 86 FEATURES Microprocessor based design with absolutely accurate and stable frequency. Panel indicators for battery voltage & load level. Compact and light weight, yet rugged and vehicle rated, 83-90% efficient. Tightly regulated output voltage and frequency Selectable 50 or 60 Hz output, all models Capable of driving highly reactive loads such as electric tools and appliances. Capable of driving highly capacitive loads such as switching power supplies. Very low harmonic distortion, THD<3%. Suitable for vehicle or wall mounting. Standard outputs 110V/60Hz, 230V/50Hz. Switch selectable ±10V output change. INPUT VDC 110 V MODELS 50 Hz or 60 Hz ELECTRICAL Input Voltage: See below Output Voltage 110V model: 100/110/120 VAC Output Voltage 220V model: 220/230/240 VAC Output Frequency: 50 or 60 HZ (Selectable) ± 0.05% Accuracy Continuous Power Rating: 300W/350VA Surge Rating: 400W/480VA Peak Output Current: 10 Amps 110V model / 5 Amps 230V model Efficiency 110V model (full load): 83% Efficiency 220V model (full load): 90% No load Current: 0.7A for 110V Models, 0.35A for 230V Models Output Waveform Sinewave: <5% THD Output Regulation: -10% / +5% All models Protection: MODEL SELECTION 230 V MODELS 50 Hz or 60 Hz MECHANICAL SPECIFICATIONS PROTECTIVE FEATURES Overload Short Circuit Reverse Polarity (Fuse) O.T, Over/Under Input Voltage Fan Failure ENVIRONMENTAL Operating Temperature: -20 to +50 C Storage Temperature: -40 C to + 70 C Humidity: To 95% non-condensing DIMENSIONS (L x W x H ) WEIGHT (Lbs.) V CGL300W CGL300W x 6.10 x V CGL300W CGL300W x 6.10 x SPECIFICATION 110 V MODELS 230 V MODELS EMI CONDUCTION AND RADIATION Compliance to FCC class B Compliance to EN55022 class B EMS IMMUNITY / Compliance to EN ,-3 LVD / Compliance to EN e-mark / Compliance to E-13*72/245/EEC,95,94/EC NOVA ELECTRIC Leader in power conversion technology since 1966 MADE IN USA

92 87 CGL600W SERIES PURE-SINEWAVE DC-AC INVERTERS 600W / 700VA 12 V, 24 V, 48 V INPUT SIX MODELS FOR 110V 50/60 Hz & 220 v 50/60 Hz APPLICATIONS Nova Electric s CGL-Series inverters are intended for commercial and industrial applications wherever pure sinewave power is needed at 50 or 60 Hz. These inverters are ideal for running electronic loads such as computers, monitors, printers, telecom systems, radios, fluorescent lamps from batteries, field generators, and solar electro-voltaic panels. They can also drive hand drills, motors and small compressors please consult the factory for proper sizing. These CGL models can also be optionally ruggedized against shock, vibration, and humidity for military applications including vehicle mounted, shipboard, submarine, aircraft, and ground fixed shelters. q COMPUTERS q SAIL BOATS q APPLIANCES q PRINTERS q PHOTO VOLTAIC q INSTRUMENTS q MONITORS q ELECTRIC TOOLS q RVs For more information, please visit us at or us at novasales@theallpower.com

93 88 STANDARD FEATURES Microprocessor based design with absolutely accurate and stable frequency. Compact and light weight, yet rugged and vehicle rated. Tightly regulated output voltage and frequency Switch selectable 50 or 60 Hz output, all models Capable of driving highly reactive loads such as electric tools and appliances. Capable of driving highly capacitive loads such as switching power supplies. Very low harmonic distortion, THD<3%. Suitable for vehicle or wall mounting. Standard outputs 110V/60Hz, 230V/50Hz. Switch selectable ±10V output change. UL / e-13 / CE / FCC Approved INPUT VDC 120 V MODELS 50 Hz or 60 Hz ELECTRICAL Input Voltage: See below Output Voltage 110V model: 100/110/120 VAC Output Voltage 220V model: 220/230/240 VAC Output Frequency: 50 or 60 HZ User Selectable ±0.05% Accuracy Continuous Power Rating: 600W/700VA Surge Rating: 800W/1000VA Peak Output Current: 10 Amps 110V model 5 Amps 230V model Efficiency 110V model (full load): 83% Efficiency 220V model (full load): 90% No load Current: 0.7A for 110V Models 0.35A for 230V Models Output Waveform Sinewave: <4% THD Output Regulation: -10% / +4% All models Protection: Overload, Short Circuit, Reverse Polarity (Fuse), O.T, Over/Under Input Voltage, Fan Failure MODEL SELECTION 220 V MODELS 50 Hz or 60 Hz MECHANICAL SPECIFICATIONS SAFETY & EMC Safety: UL458 EN60950 EMC: FCC Class B, EN :1992, EN :1992, EN55022B:1994, EN :1995, EN :1996, ENV50204:1995 e-mark e ENVIRONMENTAL Operating Temp.: -20 to +50 C Storage Temp. Range: -40 to +71 C Humidity: To 95% non-condensing INDICATORS Input level Output level Failure DIMENSIONS (L x W x H ) WEIGHT (Lbs.) V CGL600W CGL600W x 7.10 x V CGL600W CGL600W x 7.10 x V CGL600W CGL600W x 7.10 x SPECIFICATION 110 V MODELS 230 V MODELS EMI CONDUCTION AND RADIATION Compliance to FCC class A Compliance to EN55022 class A EMS IMMUNITY / Compliance to EN ,-3 LVD / Compliance to EN e-mark / Compliance to E-13*72/245/EEC,95,94/EC NOVA ELECTRIC Leader in power conversion technology since 1966 MADE IN USA

94 89 CGL1.5K SERIES PURE-SINEWAVE DC-AC INVERTERS 600W / 700VA 12 V, 24 V, 48 V INPUT SIX MODELS FOR 110V 50/60 Hz & 220 v 50/60 Hz APPLICATIONS Nova Electric s CGL-Series inverters are intended for commercial and industrial applications wherever pure sinewave power is needed at 50 or 60 Hz. These inverters are ideal for running electronic loads such as computers, monitors, printers, telecom systems, radios, fluorescent lamps from batteries, field generators, and solar electro-voltaic panels. They can also drive hand drills, motors and small compressors please consult the factory for proper sizing. These CGL models can also be optionally ruggedized against shock, vibration, and humidity for military applications including vehicle mounted, shipboard, submarine, aircraft, and ground fixed shelters. q COMPUTERS q SAIL BOATS q APPLIANCES q PRINTERS q PHOTO VOLTAIC q INSTRUMENTS q MONITORS q ELECTRIC TOOLS q RVs q MILITARY For more information, please visit us at or us at novasales@theallpower.com

95 90 FEATURES Microprocessor based design with absolutely accurate and stable frequency. Panel indicators for battery voltage & load level. Compact and light weight, yet rugged and vehicle rated, 83-90% efficient. Tightly regulated output voltage and frequency Switch selectable 50 or 60 Hz output, all models Capable of driving highly reactive loads such as electric tools and appliances. Capable of driving highly capacitive loads such as switching power supplies. Very low harmonic distortion, THD<3%. Suitable for vehicle or wall mounting. Standard inputs 10-16VDC Standard outputs 110V/60Hz, 230V/50Hz. Switch selectable ±10V output change. RS232 communication standard. Below 1W consumption in sleep mode ELECTRICAL Input Voltage: See below Output Voltage 110V model: 100/110/120 VAC Output Voltage 220V model: 220/230/240 VAC Output Frequency: 50 or 60 HZ User Selectable % Accuracy Continuous Power Rating:1500W/2000VA Surge Rating: 2000W/2500VA Peak Output Current: 25 Amps 110V model / 11 Amps 230V model Efficiency 110V model (full load): 83% Efficiency 220V model (full load): 86% No load Current: <1.0W Sleep Mode Output Waveform Sinewave: <3% THD Output Regulation: -10% / +4% All models Protection: Overload, Short Circuit, Reverse Polarity (Fuse), O.T, Over/Under Input Voltage, Fan Failure RS-232 & Remote Control Standard on all models. SAFETY & EMC Safety: UL458 EN60950 EMC: FCC Class B, EN :1992, EN :1992, EN55022B:1994, EN :1995, EN :1996, ENV50204:1995 e-mark e ENVIRONMENTAL Operating Temp: -20 to +50 C Storage Temp Range: -40 to +71 C Humidity: to 95% non condensing MODEL SELECTION CGL1.5K CGL1.5K CGL1.5K CGL1.5K CGL1.5K CGL1.5K DC Voltage 12 VDC 24 VDC 48 VDC 12 VDC 24 VDC 48 VDC Voltage Range 10.5~15.0 VDC 21.0~30.0 VDC 42.0~60.0 VDC 10.5~15.0 VDC 21.0~30.0 VDC 42.0~60.0 VDC Efficiency (Typ.) 87.0% 90.0% 92.0% 87.0% 90.0% 94.0% Low VDC Alarm 11 VDC 22 VDC 44 VDC 11 VDC 22 VDC 44 VDC Low VDC Shutdown 10.5 VDC 21.0 VDC 42.0 VDC 10.5 VDC 21.0 VDC 42.0 VDC Over Voltage 15.3 VDC 30.6 VDC 61.2 VDC 15.3 VDC 30.6 VDC 61.2 VDC No Load Current Draw 0.87 A 0.43 A 0.23 A 0.87 A 0.43 A 0.22 A Weight 15.5 Lbs. / 7 Kg. FRONT PANEL MECHANICAL SPECIFICATIONS 1.00 [25.40] 3.58 [90.93] TOP VIEW [387.60] [195.58] REAR PANEL INPUT NEG- POS+ RS-232C CHASSI S GND 4.13 [104.90] 9.65 [245.11] [262.13] [273.05] NOVA ELECTRIC Leader in power conversion technology since 1966 MADE IN USA

96 91 CGL2K SERIES PURE-SINEWAVE DC-AC INVERTERS 2000 WATTS 12 V, 24 V, 48 V INPUT 120 V 50/60 Hz or 220 V 50/60 Hz Output APPLICATIONS Nova Electric s CGL-Series inverters are intended for commercial and industrial applications wherever pure sinewave power is needed at 50 or 60 Hz. These inverters are ideal for running electronic loads such as computers, monitors, printers, telecom systems, radios, fluorescent lamps from batteries, field generators, and solar electro-voltaic panels. They can also drive hand drills, motors and small compressors please consult the factory for proper sizing. These CGL models can also be optionally ruggedized against shock, vibration, and humidity for military applications including vehicle mounted, shipboard, submarine, aircraft, and ground fixed shelters. q COMPUTERS q SAIL BOATS q APPLIANCES q PRINTERS q PHOTO VOLTAIC q INSTRUMENTS q MONITORS q ELECTRIC TOOLS q RVs q MILITARY For more information, please visit us at or us at novasales@theallpower.com

97 92 STANDARD FEATURES Microprocessor based design with absolutely accurate and stable frequency. Panel LED s for battery voltage & load level. Compact and light weight, yet rugged and vehicle rated % efficient. Tightly regulated output voltage and frequency Switch selectable 50 or 60 Hz output, all models Capable of driving highly reactive loads such as electric tools and appliances. Capable of driving highly capacitive loads such as switching power supplies. Very low harmonic distortion, THD<3%. Suitable for vehicle or wall mounting. Switch selectable ±10V output change. Loading Controlled Cooling fan. SAFETY & EMC Safety: UL458 EN60950 EMC: FCC Class B, EN :1992, EN :1992, EN55022B:1994, EN :1995, EN :1996, ENV50204:1995 e-mark e ELECTRICAL Input Voltage: See below Output Voltage 110V model: 100/110/120 VAC Output Voltage 220V model: 220/230/240 VAC Output Frequency: 50 or 60 HZ User Selectable ± 0.05% Accuracy Continuous Power Rating: 2000W Surge Rating: 4000W Efficiency 120V model (full load): 89% Efficiency 220V model (full load): 91% No load Current: <1.0W Sleep Mode Output Waveform Sinewave: <3% THD Output Regulation: -10% / +4% All models MODEL SELECTION ENVIRONMENTAL Operating Temp: -20 to +50 C Storage Temp Range: -40 to +71 C Humidity: to 95% non condensing PROTECTIVE FEATURES Input reverse polarity Undervoltage Overvoltage Output short circuit Overload Overtemperature CGL2K CGL2K CGL2K CGL2K CGL2K CGL2K DC Voltage 12 VDC 24 VDC 48 VDC 12 VDC 24 VDC 48 VDC Voltage Range 10.5~15.0 VDC 21.0~30.0 VDC 42.0~60.0 VDC 10.5~15.0 VDC 21.0~30.0 VDC 42.0~60.0 VDC Efficiency (Typ.) 89.0% 92.0% 93.0% 91.0% 94.0% 95.0% Low VDC Alarm 11 VDC 22 VDC 44 VDC 11 VDC 22 VDC 44 VDC Low VDC Shutdown 10.5 VDC 21.0 VDC 42.0 VDC 10.5 VDC 21.0 VDC 42.0 VDC Over Voltage 15.3 VDC 30.6 VDC 61.2 VDC 15.3 VDC 30.6 VDC 61.2 VDC No Load Current Draw 2.80 A 1.50 A 0.70 A 2.64 A 1.32 A 0.65 A Stand-By Current Draw 0.50 A 0.30 A 0.15 A 0.60 A 0.25 A 0.15 A Weight 20 Lbs. / 9.0 Kg. MECHANICAL SPECIFICATIONS NOVA ELECTRIC Leader in power conversion technology since 1966 MADE IN USA

98 93 CGL3K SERIES PURE-SINEWAVE DC-AC INVERTERS 3000 WATTS 12 V, 24 V, 48 V INPUT 120 V 50/60 Hz or 220 V 50/60 Hz Output APPLICATIONS Nova Electric s CGL-Series inverters are intended for commercial and industrial applications wherever pure sinewave power is needed at 50 or 60 Hz. These inverters are ideal for running electronic loads such as computers, monitors, printers, telecom systems, radios, fluorescent lamps from batteries, field generators, and solar electro-voltaic panels. They can also drive hand drills, motors and small compressors please consult the factory for proper sizing. These CGL models can also be optionally ruggedized against shock, vibration, and humidity for military applications including vehicle mounted, shipboard, submarine, aircraft, and ground fixed shelters. q COMPUTERS q SAIL BOATS q APPLIANCES q PRINTERS q PHOTO VOLTAIC q INSTRUMENTS q MONITORS q ELECTRIC TOOLS q RVs q MILITARY For more information, please visit us at or us at novasales@theallpower.com

99 94 FEATURES True sinewave output THD < 3% Input and output fully isolated Load controlled cooling fan Advanced microprocessor control Output frequency 50/60 Hz switch selectable Low power saving mode to conserve energy e-13 / CE / FCC approved PROTECTIVE FEATURES Input reverse polarity Undervoltage Overvoltage Output short circuit Overload Overtemperature ELECTRICAL Input Voltage: 12, 24 or 48VDC Output Voltage 110V models: 100/110/120 VAC Output Voltage 230V models: 220/230/240 VAC Rated Power: 2000W Surge Power: 4000W Frequency: 50 or 60 HZ switch selectable AC Regulation: +/- 3% Std. Rceptacles 110V models: NEMA5-20r Std. Rceptacles 220V models: Schuko Led Indicators: Input voltage level, output load level and fault status ENVIRONMENTAL Operating Temp: -20 to +50 C Storage Temp Range: -40 to +71 C Humidity: to 95% non condensing MODEL SELECTION SAFETY & EMC Safety Standards: UL458 (with optional GFCI outlet only) Isolation Resistance: I/P - O/P: 100M Ohms / 500VDC FOR 110V Models EMI Conduction and Radiation: Compliance to FCC class A FOR 230V Models EMI Conduction and Radiation: Compliance to EN55022 class A EMS Immunity: Compliance to EN ,3 LVD: Compliance to EN e-mark: Compliance to e-13 * 72/245/EEC, 95/54/EC CGL3K CGL3K CGL3K CGL3K CGL3K CGL3K DC Voltage 12 VDC 24 VDC 48 VDC 12 VDC 24 VDC 48 VDC Voltage Range 10.5~15.0 VDC 21.0~30.0 VDC 42.0~60.0 VDC 10.5~15.0 VDC 21.0~30.0 VDC 42.0~60.0 VDC Efficiency (Typ.) 88.0% 91.0% 92.0% 90.0% 93.0% 94.0% Low VDC Alarm 11 VDC 22 VDC 44 VDC 11 VDC 22 VDC 44 VDC Low VDC Shutdown 10.5 VDC 21.0 VDC 42.0 VDC 10.5 VDC 21.0 VDC 42.0 VDC Over Voltage 15.3 VDC 30.6 VDC 61.2 VDC 15.3 VDC 30.6 VDC 61.2 VDC No Load Current Draw 2.00 A 1.60 A 0.80 A 2.80 A 1.50 A 0.70 A Stand-By Current Draw 0.55 A 0.35 A 0.19 A 0.50 A 0.35 A 0.19 A Weight 20 Lbs. / 9.0 Kg. MECHANICAL SPECIFICATIONS NOVA ELECTRIC Leader in power conversion technology since 1966 MADE IN USA

100 95 RUGGED GALAXY SERIES SOLID-STATE FREQUENCY CONVERTERS SINGLE PHASE 120 VA KVA APPLICATIONS Nova frequency converters are high-reliability power sources specifically designed for demanding applications in high shock, vibration, humidity, and EMI environments. They can be built to meet MIL-STD-810, MIL-STD-1399, MIL-STD-1472, MIL-STD-461, and other standards optionally. They are suitable for severe environment and high reliability applications such as: q MILITARY q AIRCRAFT POWER q U.S. POWER ABROAD HMMWV UAV Shipboard Submarine Aircraft Mobile Power Units Shelters q AC POWER FROM VEHICLE BATTERY q CELLULAR SITES q POWER CONDITIONING & FREQUENCY STABILIZATION q RAILROAD SIGNALING POWER q COMMUNICATIONS SYSTEMS q EUROPEAN POWER / EXPORT TESTING For more information, please visit us at or us at novasales@theallpower.com

101 96 FEATURES Solid-State Design Advanced Modular Capabilities Pure Sinewave Output Lightweight, extremely compact enclosures High reliability OV, O.L. and O.T. protected MTTR below 30 minutes; modular design Withstands high reactive load Tight voltage and frequency regulation Boards are conformal coated AVAILABLE OPTIONS Ruggedization to meet MIL-STD-810 shock, vibration and humidity Wide temperature range -40 C to +71 C Special output voltages and frequencies 19, 23, or 24 Panel Mount MS Connectors or outlets Custom painting and marking Heavy-Duty Handles High inrush for motor start Wall Mount Plate Chassis slides (rack mount models only) Custom NEMA Wall-Mount or Floor-Mount Enclosures Frequency Meters Elapsed Time Meter Alarm Contact Closures Remote Start / Stop Control Output Circuit Breaker Crystal Frequency Control Contacts for Remote Operation Dual Output Safety Door Locks (Cabinet Models) +/- 10% Output Voltage Adjustment (located on front door of Cabinet Models) Heavy Duty Casters (Cabinet Models) Rail Frequency Hz 83, 91.66, 100, 200, or 250 Hz. Ethernet / SNMP or RS232 SPECIFICATIONS Power Ratings: 120 VA 7.5+ KVA Input Voltage: Most standard AC voltages including 115, 120, 200, 208, 220, 240, 277, 380, and 480 available in single and three-phase configurations. Output Voltage: Most standard AC voltages including 115, 120, 200, 208, 220, 240, 277, 380, and 480 available in single and three-phase configurations. Frequency: 50 Hz, 60 Hz, or 400 Hz (±0.5%) Frequency Regulation: ±0.5% N.L. to F.L. (Crystal available) Frequency Transients: None MODEL SELECTION Voltage Regulation: ±1.5% N.L. to F.L. Efficiency: Approximately 85-95% (depending on model) Total Harmonic Distortion: 3% Typical, 5% Max Overload: 120% Typical Power Factor: 0.7 Lead to 0.7 Lag Input Circuit Protection: Circuit Breaker / Fuses, Transient Suppressors Output Circuit Protection: Current Limit, Short Circuit Protection, Thermal Protection, and Semi-Conductor Protection Phase Rotation: Any (three-phase models) ENVIRONMENTAL Operating Temp: -20 C to +50 C Standard -40 C to +71 C Optional Cooling: Forced Air by internal fan Vibration: Normal shipping and handling Shock: 20g, 11 ms half sinewave Designed to meet MIL-STD-810 optionally Elevation: 10,000 ft. typical Humidity: to 95% RH non-condensing Designed to meet MIL-STD-810. All boards conformal coated with Acrylic MIL-I Type R. Audible Noise: 65 dba at 5 ft. typical EMI: Designed to meet FCC Part 15, Class A. Designed to meet MIL-STD-461 with optional additional filtering. MTBF: 30,000+ hours typical per MIL-MDBK-217 MTTR: Less than 30 minutes. Partial Model Number KVA VOLTAGE FREQUENCY WEIGHT (Lbs.) DIMENSIONS (H x W x D) Partial Model Number KVA VOLTAGE FREQUENCY WEIGHT (Lbs.) DIMENSIONS (H x W x D) GSFC5050 GSFC5060 GSFC x x GSFC3K50 GSFC3K x x GSFC1K50 GSFC1K60 GSFC1K400 GSFC1.5K50 GSFC1.5K60 GSFC1.5K400 GSFC2K50 GSFC2K60 GSFC2K x x x x x x GSFC3K x x GSFC4K50 GSFC4K60 GSFC4K400 GSFC5K50 GSFC5K60 GSFC5K400 GSFC7.5K50 GSFC7.5K60 GSFC7.5K x x x x x x MECHANICAL SPECIFICATIONS TYPICAL GSFC 1-2 KVA CHASSIS SEE TOP COVER SCREEN BELOW FOR DETAILS NOTES: 1. ALL DIMENSIONS ARE IN INCHES. 2. EXTERIOR ANSI# 61 GRAY SEMI-GLOSS. 3. HANDLES PROJECT 1.50 INCHES FROM PANEL SURFACE. AIR INTAKE AIR EXHAUST FAN SHOCK BLOCK W/GUIDE PIN SUPPLIED (OPTIONAL) (OPTIONAL) CHASSIS SLIDES (BOTH SIDES) GENERAL DEVICES PN: CTS-120 (OPTIONAL) J2 AC MS3102 AC INPUT AC REAR VIEW AC INPUT MS NOVA ELECTRIC Leader in power conversion technology since 1966 MADE IN USA

102 97 RUGGED GALAXY SERIES SOLID-STATE FREQUENCY CONVERTERS THREE PHASE 1.5 KVA KVA APPLICATIONS Nova frequency converters are high-reliability power sources specifically designed for demanding applications in high shock, vibration, humidity, and EMI environments. They can be built to meet MIL-STD-810, MIL-STD-1399, MIL-STD-1472, MIL-STD-461, and other standards optionally. They are suitable for severe environment and high reliability applications such as: q MILITARY q AIRCRAFT POWER q U.S. POWER ABROAD HMMWV UAV Shipboard Submarine Aircraft Mobile Power Units Shelters q AC POWER FROM VEHICLE BATTERY q CELLULAR SITES q POWER CONDITIONING & FREQUENCY STABILIZATION q RAILROAD SIGNALING POWER q COMMUNICATIONS SYSTEMS q EUROPEAN POWER / EXPORT TESTING For more information, please visit us at or us at novasales@theallpower.com

103 98 FEATURES Solid-State Design Advanced Modular Capabilities Pure Sinewave Output Lightweight, extremely compact enclosures High reliability OV, O.L. and O.T. protected MTTR below 30 minutes; modular design Withstands high reactive load Tight voltage and frequency regulation Boards are conformal coated AVAILABLE OPTIONS Power Factor correction available on selected GLFC-Series models. Ruggedization to meet MIL-STD-810 shock, vibration and humidity Wide temperature range -40 C to +71 C Special output voltages and frequencies 19, 23, or 24 Panel Mount MS Connectors or outlets Custom painting and marking Heavy-Duty Handles High inrush for motor start Wall Mount Plate Chassis slides (rack mount models only) Partial Model Number GLFC1.5K3/5 GLFC1.5K3/6 MODEL SELECTION KVA VOLTAGE FREQUENCY / / MECHANICAL SPECIFICATIONS WEIGHT (Lbs.) DIMENSIONS (H x W x D) x x GLFC1.5K3/ / x x GLFC2K3/5 GLFC2K3/ / / x x GLFC2K3/ / x x GLFC3K3/5 GLFC3K3/ / / x x GLFC3K3/ / x x GLFC4.5K3/5 GLFC4.5K3/6 4.5 Custom NEMA Wall-Mount or Floor-Mount Enclosures Frequency Meters Elapsed Time Meter Alarm Contact Closures Remote Start / Stop Control Output Circuit Breaker Crystal Frequency Control Contacts for Remote Operation Dual Output +/- 10% Output Voltage Adjustment (located on front door of Cabinet Models) SPECIFICATIONS Power Ratings: 1.5KVA 4.5KVA Input Voltage: Most standard AC voltages including 115, 120, 200, 208, 220, 240, 277, 380, and 480 available in single and three-phase configurations. Power Factor correction available on selected GLFC-Series models. Output Voltage: Most standard AC voltages including 115, 120, 200, 208, 220, 240, 277, 380, and 480 available in single and three-phase configurations. Frequency: 50 Hz, 60 Hz, or 400 Hz (±0.5%) Frequency Regulation: ±0.5% N.L. to F.L. (Crystal available) Frequency Transients: None Voltage Regulation: ±1.5% N.L. to F.L. Efficiency: Approximately 85-95% (depending on model) 220/ / Total Harmonic Distortion: 3% Typical, 5% Max Overload: 120% Typical Power Factor: 0.7 Lead to 0.7 Lag Input Circuit Protection: Circuit Breaker / Fuses, Transient Suppressors Output Circuit Protection: Current Limit, Short Circuit Protection, Thermal Protection, and Semi-Conductor Protection Phase Rotation: Any (three-phase models) ENVIRONMENTAL Operating Temp: -20 C to +50 C Standard -40 C to +71 C Optional Cooling: Forced Air by internal fan Vibration: Normal shipping and handling Shock: 20g, 11 ms half sinewave Designed to meet MIL-STD-810 optionally Elevation: 10,000 ft. typical Humidity: to 95% RH non-condensing Designed to meet MIL-STD-810. All boards conformal coated with Acrylic MIL-I Type R. Audible Noise: 65 dba at 5 ft. typical EMI: Designed to meet FCC Part 15, Class A. Designed to meet MIL-STD-461 with optional additional filtering. MTBF: 30,000+ hours typical per MIL-MDBK-217 MTTR: Less than 30 minutes x x GLFC4.5K3/ / x x SEE TOP COVER SCREN BELOW FOR DETAILS MS3102R AIR INTAKE (BOTH SIDES) CHASSIS SLIDES (BOTH SIDES) GENERAL DEVICES P/N: CTS-120 (OPTIONAL) NOVA ELECTRIC Leader in power conversion technology since 1966 MADE IN USA

104 99 RUGGED GALAXY SERIES SOLID-STATE FREQUENCY CONVERTERS COMPACT 1U-4U CHASSIS 700W - 4KW POWER UNIVERSAL 120/240 VAC PFC INPUT Hz OPTIONAL SNMP COMMUNICATIONS APPLICATIONS Nova s Ultra Lightweight Galaxy-Series Solid-State Frequency Converter Systems are highreliability power sources specifically designed for demanding applications in high shock, vibration, humidity, and EMI environments in compliance to MIL-STD-1399, MIL-STD-461, MIL-S-901, MIL-STD-167, MIL-STD-810, MIL-STD-740, and DOD-STD These models offer maximum field-proven reliability for severe environment and high reliability applications such as: q MILITARY q AIRCRAFT POWER q U.S. POWER ABROAD HMMWV UAV Shipboard Submarine Aircraft Mobile Power Units Shelters q AC POWER FROM VEHICLE BATTERY q CELLULAR SITES q POWER CONDITIONING & FREQUENCY STABILIZATION q RAILROAD SIGNALING POWER q COMMUNICATIONS SYSTEMS q EUROPEAN POWER / EXPORT TESTING For more information, please visit us at or us at novasales@theallpower.com

105 100 FEATURES Ruggedization against high shock, vibration and humidity MS connector mates and multiple output outlets Chassis Slide Guides Custom Enclosures Ø Power Input 400 Hz input and / or output Output breaker PROTECTIVE FEATURES Input Circuit Breakers Automatic Overload & Short Circuit Protection Thermal Protected Input Under/Overvoltage Protected Optional Audible Alarm with Silence Switch NOMINAL DIMENSIONS Dimensions: 19 Wide x 24 Deep (See chart for height) Partial Model Number GLFCPFC-5K60-120/240A-120-4U GLFCPFC-3K60-120/240A-120-4U GLFCPFC-3K60-120/240A-120-3U GLFCPFC-2K60-120/240A-120-3U GLFCPFC-1.5K60-120/240A U GLFCPFC-1K60-120/240A-120-1U KVA KW NOMINAL INPUT VAC VAC VAC VAC VAC VAC ELECTRICAL Input Voltage: 120/240 VAC Autoselect PFC (3Ø input optional) Output Voltage: 120/208/230 VAC (specify) Frequency: 50 / 60 / 400 Hz. Available Voltage Regulation: ± 2% NL to FL Frequency Regulation: ± 0.5% NL to FL Harmonic Distortion: 5% THD, 3% typical Input Power Factor: 0.95 or half-full load Efficiency at full load: full load typical Overload: 110% load for 10 minutes 115% load for 5 minutes 120% load for 2 minutes Connections: MS Connector (mates opt.). OPTIONAL REMOTE CONTACTS / COMMUNICATIONS SNMP V1.0 (Available-Optional) via CAT-5 Connector RS 232 (Available-Optional) Via DB 9 Connector 50/60 Hz MODEL SELECTION (400 Hz Available) INPUT FREQ. 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz VAC FREQ. WEIGHT (Lbs.) HEIGHT Hz 45 4U Hz 42 4U Hz 40 3U Hz 40 3U Hz 30 2U Hz 25 1U Partial Model Number GLFCPFC-5K50-120/240A-230-4U GLFCPFC-3K50-120/240A-230-4U GLFCPFC-3K50-120/240A-230-3U GLFCPFC-2K50-120/240A-230-3U GLFCPFC-1.5K50-120/240A U GLFCPFC-1K50-120/240A-230-1U MECHANICAL SPECIFICATIONS KVA KW Alarm Contacts (Available-Optional) Optional Audible Alarm with Silence Switch. ENVIRONMENTAL Operating Temp.: -20 to +50 C (Extended ranges optional) Storage temperature range: -40 to +71 C Humidity: to 95% RH non-condensing per MIL-STD-810. All boards conformal coated with Acrylic MIL-I Type R. Elevation: 15,000 ft. (4,572m) operating; 40,000 ft. (12,192m) non-operating Shock: 20g, 11 ms half sinewave per MIL-STD-810 Audible Noise: Less than 55 dba at 5 ft. EMI: MIL-STD-461 ENVIRONMENTAL MTBF: 100,000+ hours per field +25C Ambient Ground-Fixed MTTR: 30 minutes by qualified personnel NOMINAL INPUT VAC VAC VAC VAC VAC VAC INPUT FREQ. 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz VAC FREQ. WEIGHT (Lbs.) HEIGHT Hz 45 4U Hz 42 4U Hz 40 3U Hz 40 3U Hz 30 2U Hz 25 1U TYPICAL 2U CHASSIS NOVA ELECTRIC Leader in power conversion technology since 1966 MADE IN USA

106 101 JUPITER SERIES 3Ø FREQUENCY CONVERTER 10KVA TO 450+ KVA THREE PHASE 50/60/400 Hz Sine-wave GALVANIC ISOLATED APPLICATIONS Nova s Jupiter-Series Solid-State Frequency Converters are high-reliability power sources specifically designed for demanding commercial, heavy industrial, and military applications. They can be built to meet MIL-STD-810, MIL-S-901, MIL-STD-461, and other standards optionally. These models utilize True On-Line technology and the most durable components, offering maximum field-proven reliability for severe environment and high reliability applications. Singlephase input and/or output models are available upon request. q MILITARY APPLICATIONS q q q q q q VEHICULAR SHIPBOARD AIRCRAFT SHELTER COMMUNICATION SYSTEMS CELLULAR SITES EUROPEAN POWER/EXPORT TESTING POWER CONDITIONING & FREQUENCY STABILITY US POWER ABROAD RAILROAD SIGNALING POWER FEATURES Complete input to output Galvanic isolation. High frequency (almost silent) operation Push button starting and stopping Diagnostic panel with LCD and LED display Soft start Maintenance free batteries can be added for UPS capability (consult factory) Overload and short circuit protection All electronics are built in modular front access and front removable sub assemblies for easy service and maintenance Batteries may be built into units up to 20KVA Available options to meet military specs E/F Circuit for aircraft applications Parallel option for increased power For more information, please visit us at or us at novasales@theallpower.com

107 JUPITER SERIES 3Ø FREQUENCY CONVERTER MONITORING The Converter includes an RS232 communication option called UPSCOM. This is an RS232 connection to a PC that can monitor the three phase information related to the converter output and any abnormal conditions that have occurredin real time. Standard commercially available software is provided. The RS232 Feature is included at no additional charge. FRONT PANEL LCD DISPLAY AND LED INDICATORS - These will report all Converter parameters, including input and output voltages, currents, frequency, DC voltage, current, and many other functions. LCD DISPLAY - Real time status, data, and historical events are displayed by the LCD display. The Converter parameters, real time clock, and buzzer alarm also can be set through this LCD. The LCD is backlit by LEDs for easy visuals. STATUS LEDs - A series of LEDs representing all the important status information of the Converter provide information to the user. These LEDs are especially important when abnormal conditions occur. Since these LEDs are located behind the transparent window, the user can see them clearly without opening the door. LED descriptions are as follows: CONVERTER ON Converter is running normally. CONVERTER SS Converter static switch is on while the reserve static switch is opened (off). SHORT CIRCUIT Converter output is in short circuit state. FUSE / OVERTEMP SD Converter has shut down due to either fuse open or high temperature. CONVERTER FAIL SHUT DOWN Converter has shut down due to low converter AC output. BYPASS ON SHUT DOWN Converter shut down due closed bypass breaker (while inverter running). OVERLOAD SHUT DOWN Converter shut down due to overload of the converter for a period greater than the converter can accept. The converter will start after 7 seconds. 70% LOAD load connected to the output is over 70% of the converter rating. 110% LOAD load connected to the output is over 110% of the converter rating. 125% LOAD load connected to the output is over 125% of the converter rating. 150% LOAD load connected to the output is over 150% of the converter rating. RESERVE AC FAIL reserve AC magnitude is out of range. RESERVE FREQ FAIL reserve frequency is out of range. BATTERY LOW - DC bus (or battery) is lower than specified range. Low battery shut down will occur soon. BATTERY LOW SHUT DOWN Converter shut down due to DC bus (or battery) lower than the acceptable DC voltage of the converter. COMMUNICATION OPTIONS Some popular communications options available at additional cost include the following: UPSCAN: This is a hand held remote display and control module with LCD and LED display that can monitor up to 99 converter units via RS- 485 at a remote distance of up to 3,000 feet. NETAGENT: This provides capability to monitor the converter over the internet. It includes the appropriate additional SNMP card and microprocessor. The software required is provided separately. EMERGENCY STOP Converter shutdown activated by emergency stop switch. DATA LINE Blink when data is transmitted to or received from the communication port. 102 WARNING LEDs When abnormal condition occurs, these LEDs will light to warn the user of the cause of the fault condition. Therefore all these LEDs are off under normal condition. These LEDs are: RECT AC FAIL Rectifier AC input is abnormal either due to AC magnitude out of the range or phase rotation error; rectifier shut down. RESERVE FAIL Reserve AC input is abnormal either due to AC magnitude out of range or frequency out of range. FUSE/TEMP - Either converter fuse is open or over temperature has occurred. OVERLOAD Output is overloaded by over 110%, 125% or 150% HIGH DC This LED will light as long as the DC voltage is over 430VDC. BAT LOW This LED will light when the DC voltage is lower than 320VDC. BAT LOW STOP This LED will light when the DC voltage is lower than 295VDC, inverter on is inhibited. FAULT The converter is off due to abnormal conditions such as overload, short circuit, high DC fuse over temperature, bypass breaker on emergency stop. AUDIBLE ALARM The audible alarm will beep under one of the following conditions: CONVERTER IS OVERLOADED: 110% beep once every 3 seconds 125% beep once every second 150% beep twice every second CONVERTER IS SHORT CIRCUITED Beeps continuously FUSE OPEN Beeps continuously HEAT SINK OVER TEMPERATURE Beeps continuously HIGH DC SHUTDOWN Beeps continuously BYPASS ON STOP Beeps continuously EMERGENCY ON STOP Beeps continuously. The buzzer will also beep once every time the converter is switched on or off to acknowledge to the user that his key entry is valid and accepted. OTHER OPTIONS SHOCK MOUNT OPTION The cabinet can be shock mounted using optional rubber or coil type isolators. This will enable the unit to withstand shock levels as specified in MIL-S-901 RUGGEDIZING OPTION This option will add conformal coating and other additional internal structural members to allow the unit to meet many portions of MIL-STD-810 including shock, vibration, and humidity. TURN ON SERVICE OPTION We offer a turn on service that will ensure the Converter has been properly installed and the full warranty is in effect (failures caused by incorrect installation are not covered by the warranty.) If this option is selected, the customer will also automatically receive an additional 3 months added to the warranty at no additional charge. SPARE PARTS KIT OPTION We offer a spare parts package that includes one of each board, spare fuses, spare semiconductors, and spare fans. These spare part kits are priced lower when ordered with the initial order than if they are ordered later on. DRIP SHIELD OPTIONS This option offers protection against falling or dripping liquids. CUSTOMIZED EPO This feature can be customized to trip off current breakers or perform other inhibits depending customer needs. NOVA ELECTRIC Leader in power conversion technology since 1966 MADE IN USA

108 103 JUPITER SERIES 3Ø FREQUENCY CONVERTER KVA Input Voltage (VAC) Input Range Input Frequency Input Frequency Range Power Walk In Please Specify 120/ / / / / delta 240 3delta 380 3delta 400 3delta 480 3delta +/- 20% (>+20% is available upon request) Please Specify: 50 Hz or 60 Hz or 400 Hz ± 5% (wider ranges offered, please consult factory) 0% - 100%: 20 sec Rectifier 98% Rectification Type 6 Pulse Standard, 12 Pulse Optional 12 Pulse Standard Output Voltage (VAC) Wave Form Output Power Factor Output Freq. (Free Running) Phase Shift Under 100% Unbalanced Load Please Specify 120/ / / / / delta 240 3delta 380 3delta 400 3delta 480 3delta Sinewave 0.7 lead to lag Please Specify: 50 Hz or 60 Hz or 400 Hz (crystal controlled) , 100 or 250 Hz optional <0.5% THD (Linear Load) < 2% <110% Continuous OVERLOAD % 15 minutes % 10 minutes >150% 1 minute Efficiency (100% Load)(%) Overall Efficiency (%) Maximum Heat Dissipation (KW) Full Load 2.4 K 4.8 K 6.5 K 8.9 K 10.3 K 12 K 16 K 19 K 22 K 30 K 45 K 60 K 86 K Audible Noise <65 dba (at 1m) <67dBA (at 1m) Temperature Humidity Altitude EN ,-2 Short Circuit Protection MTBF -10 C to +50 C (Extended ranges available) 0%-95% (Non-condensing) <1500 m Above Sea Level Yes Yes 100,000 Hours for loss of AC Output Lighting/EMC Filter MOV / Input & Output ( FCC CLASS A) Galvanic Isolation LED, LCD Audible Alarm Remote Control/ Communication Interface Input and Output True Galvanic Isolation Yes Monitoring 1~99 Units simultaneously / Dry Contact, RS-232, RS-485 (Optional) For more information, please visit us at or us at novasales@theallpower.com

109 JUPITER SERIES 3Ø FREQUENCY CONVERTER 50 Hz MODELS KVA KW IN (VAC) OUT (VAC) DIMMENSIONS (H x W x D) WEIGHT (KG) JFC10K3/5-120/ / / /380 63" x 22" x 31.5" JFC20K3/5-120/ / / /380 63" x 22" x 31.5" JFC30K3/5-120/ / / /380 63" x 22" x 31.5" JFC40K3/5-120/ / / /380 63" x 22" x 31.5" JFC50K3/5-120/ / / /380 63" x 22" x 31.5" JFC60K3/5-120/ / / /380 63" x 22" x 31.5" JFC80K3/5-120/ / / /380 63" x 43.3" x 31.5" JFC100K3/5-120/ / / /380 63" x 43.3" x 31.5" JFC120K3/5-120/ / / /380 63" x 43.3" x 31.5" JFC160K3/5-120/ / / /380 63" x 43.3" x 31.5" JFC200K3/5-277/ / / /380 63" x 87.0" x 31.5" JFC240K3/5-277/ / / /380 63" x 87.0" x 31.5" JFC300K3/5-277/ / / /380 63" x 87.0" x 31.5" JFC320K3/5-277/ / / /380 63" x 87.0" x 31.5" JFC450K3/5-277/ / / /380 63" x 130" x 31.5" Hz MODELS KVA KW CONTACT FACTORY FOR SINGLE PHASE MODELS IN (VAC) OUT (VAC) DIMMENSIONS (H x W x D) WEIGHT (KG) JFC10K3/6-220/ / / /208 63" x 22" x 31.5" JFC20K3/6-220/ / / /208 63" x 22" x 31.5" JFC30K3/6-220/ / / /208 63" x 22" x 31.5" JFC40K3/6-220/ / / /208 63" x 22" x 31.5" JFC50K3/6-220/ / / /208 63" x 22" x 31.5" JFC60K3/6-220/ / / /208 63" x 22" x 31.5" JFC80K3/6-220/ / / /208 63" x 43.3" x 31.5" JFC100K3/6-220/ / / /208 63" x 43.3" x 31.5" JFC120K3/6-220/ / / /208 63" x 43.3" x 31.5" JFC160K3/6-220/ / / /208 63" x 43.3" x 31.5" JFC200K3/6-220/ / / /480 63" x 87.0" x 31.5" JFC240K3/6-220/ / / /480 63" x 87.0" x 31.5" JFC300K3/6-220/ / / /480 63" x 87.0" x 31.5" JFC320K3/6-220/ / / /480 63" x 87.0" x 31.5" JFC450K3/6-380(3)-277/ /480 63" x 130" x 31.5" Hz MODELS KVA KW IN (VAC) OUT (VAC) DIMMENSIONS (H x W x D) WEIGHT (KG) JFC10K3/4-120/ / / /200 63" x 22" x 31.5" JFC20K3/4-120/ / / /200 63" x 22" x 31.5" JFC30K3/4-120/ / / /200 63" x 22" x 31.5" JFC40K3/4-120/ / / /200 63" x 22" x 31.5" JFC50K3/4-120/ / / /200 63" x 22" x 31.5" JFC60K3/4-120/ / / /200 63" x 22" x 31.5" JFC80K3/4-120/ / / /200 63" x 43.3" x 31.5" JFC100K3/4-120/ / / /200 63" x 43.3" x 31.5" JFC120K3/4-120/ / / /200 63" x 43.3" x 31.5" JFC160K3/4-120/ / / /200 63" x 43.3" x 31.5" JFC200K3/4-277/ / / /200 63" x 87.0" x 31.5" JFC240K3/4-277/ / / /200 63" x 87.0" x 31.5" JFC300K3/4-277/ / / /200 63" x 87.0" x 31.5" JFC320K3/6-220/ / / /200 63" x 87.0" x 31.5" JFC450K3/6-380(3)-277/ /480 63" x 130" x 31.5" WEIGHT (Lbs) WEIGHT (Lbs) WEIGHT (Lbs) 104 NOVA ELECTRIC Leader in power conversion technology since 1966 MADE IN USA

110 105 JUPITER SERIES 3Ø FREQUENCY CONVERTER TYPICAL DIMENSION DRAWINGS (22 WIDE) For more information, please visit us at or us at

111 JUPITER SERIES 3Ø FREQUENCY CONVERTER TYPICAL DIMENSION DRAWINGS (43.5 WIDE) 106 NOVA ELECTRIC Leader in power conversion technology since 1966 MADE IN USA

112 107 JUPITER SERIES 3Ø FREQUENCY CONVERTER TYPICAL DIMENSION DRAWINGS (87 WIDE) For more information, please visit us at or us at

113 POWER CONVERSION ACCESORIES 108 RUGGED PORTABLE TRANSFORMERS Nova Electric s transformers are all designed and built in house to exact customer specifications from 250 W to 500+ KW and beyond. Transformers are available in freestanding, rack mount (with or without chassis slides and shock bull pin receptacles,) or sealed portable enclosures appropriately ruggedized for military or harsh environment applications. Connectors and other miscellaneous options can be ordered as per unique customer requirements. CUSTOM EMI FILTERS Nova s extensive experience in designing and manufacturing MIL-STD-461 compliant UPSs, DC-AC Inverters, and Frequency Converters allows us to design and build custom EMI Filters which attenuate conducted emissions to comply with the CE102 limit. EXTERNAL MAINTENANCE BYPASS SWITCHES In applications where external MBS are required in harsh environments, industrial grade products often fall short in being able to withstand high shock, vibration, and humidity for extended periods of time. Now, the same standalone MBSs previously only supplied with Nova s military power conversion equipment are available for purchase on their own. Rack mount and bulkhead mount versions are available, all featuring the same ruggedized construction that allows our supplies to be qualified to MIL-STD-810, MIL-STD-167, MIL-S-901, and other related environmental standards. POWER DISTRIBUTION UNITS (PDUs) Nova Electric offers a full line of COTS and MOTS Power Distribution Units (PDU) designed to manage power capacity and functionality for military and harsh environment applications. The same robust construction that characterizes our MIL-STD-810, MIL-S-901 and MIL-STD-167 AC Power Sources applies to our PDUs, which are also available with enhanced filtering to meet MIL-STD-461 and Tempest-Grade requirements. NOVA ELECTRIC Leader in power conversion technology since 1966 MADE IN USA

114 IV QUALITY ASSURANCE RELIABILITY AND SERVICEABILITY (MTBF & MTTR) Reliability is a feature that is designed and integrated into every piece of equipment that carries the Nova Electric name. This is accomplished by utilizing state of the art circuitry which substantially reduces the total number of components (especially heat producing components). The result is greater efficiency, high reliability and low cost. In fact, a study of installed units has indicated an MTBF of over 100,000 hours! MTBF figures are based upon ground fixed normal 25-degree ambient temperature and proper and preventive maintenance. The MTTR for all items offered is approximately 30 minutes. This is published on the data sheets for the offered items. Part of the maintenance and repair philosophy of the units is to use the BIT equipment to aid in fault isolation. At that point, a decision is made to either replace an LRU within the power supply with a spare. The MTTR value specified is based upon proper training of local maintenance technicians and engineers. QUALITY CONTROL Nova Electric obtained AS9100C:ISO9001:2008 Quality Management System Standard Registration by Bureau of Veritas on October 15, This is a testament to Nova Electric s years of experience with formal Quality Assurance/Control Systems and procedures that remain in compliance with AS9100C, ISO19011, AS9102, AS9104, MIL-I-45208A, and MIL-STD-45662A requirements. Certification of Compliance to AS9100C ensures product safety and reliability. As part of the upgrade to the AS9100 System, the organization has implemented risk as a critical factor within its QMS. Internal Auditors are certified and trained by ANAB accredited certification bodies. Nova Electric maintains both a Counterfeit Risk Part Prevention Program, as well as a Part Obsolesce Prevention Program, which are in accordance to AS5553 and MIL-STD Third party laboratories are contracted for calibration in compliance with ANSI/NCSL Z540. In addition, operators and inspectors are certified to J-STD-001 and IPC-A-610 Class 2 (formerly MIL-STD-2000) for soldered assemblies. Instructors on staff have been certified by the DOD to MIL-STD-2000 category C as far back as 1990, the year following release of this soldering standard. Long before AS9100 or ISO 9000 became marketing buzzwords, Nova Electric s configuration controls, process controls, and ESD controls were approved by customers from both the government (military) and industry. Nova Electric s commercial (COTS) products benefit from the same quality systems originally developed for our military customers MILITARY AND RUGGED COMMERCIAL (COTS) DESIGNS All of Nova Electric s products feature robust build quality and rugged designs. They are suitable for demanding military, industrial, and commercial applications. Most products can be equipped to meet MIL-STD-461, MIL-STD-810, MIL-S-901, MIL-STD-167, MIL-STD-1399, MIL-STD-1472, and other important specifications as required. Please consult the factory about your specific application. GOVERNMENT QUALITY ASSURANCE Our Quality Assurance Department will be glad to work with the designated Government Quality Assurance Representative (GQAR) on government or military projects. HAZARDOUS MATERIALS As is usually required for most applications, we certify that there is no asbestos material or mercury in our rugged AC Power Sources. MSDS are available from the factory for batteries used in our UPS Systems. For more information, please visit us at or us at novasales@theallpower.com

115 OTHER DIVISIONS QTHER V TECHNOLOGY DYNAMICS INC. SWITCHING POWER SUPPLIES DC TO DC CONVERTERS HOT SWAP POWER SYSTEMS Integration Solutions MID-EASTERN INDUSTRIES RUGGED & MIL-SPEC PRINTERS Division of TECHNOLOGY DYNAMICS LINEAR POWER SUPPLIES ULTRA LOW NOISE AND VERY HIGH PRECISION LABORATORY MILITARY Also Custom Linear Systems Up to 10KW NIS PRINTER ON THE Shuttle Carrier Aircraft (SCA) Design excellence since 1976! Reliable Power Where You Need It TECHNOLOGY DYNAMICS INC SHOCK ISOLATED COLOR INKJET Switching P. S, DC-DC Converters & DC UPS RUGGED COLOR LASER NOVA Integration Solutions 19 East 17th Street, Saint Cloud, Florida Phone: Web: MIL-SPEC WIDE FORMAT Applications: NOVA INTEGRATION SOLUTIONS Rugged Printers, VME, ATR Automatic Test System Medical Military towed arrays Down Hole exploration Industrial Process Control MID EASTERN INDUSTRIES Linear Power Supplies, Programmable P.S. Electronics Integration Technology Inc. subsidiary of Technology Dynamics Inc. PC BOARD SERVICES SMT PCB PROTOTYPING CO M P L E X B OX A S S E M B LY S YS T E M S I N T E G R AT I O N FINAL TESTING NOVA BATTERY SOLUTIONS Battery packs for medical devices and instrumentation devices THE ALL POWER SOURCE Components for power conversion 10 Industrial Way East, Eatontown, NJ Phone: Fax: info@eit-inc.com ELECTRONIC INTEGRATION TECHNOLOGY Contract manufacturing NOVA ELECTRIC Leader in power conversion technology since 1966 MADE IN USA

Chloride EDP Series Three-Phase UPS ( kva): The EDP Series UPS is designed

Chloride EDP Series Three-Phase UPS ( kva): The EDP Series UPS is designed R A H I G H E R L E V E L O F C O N F I D E N C E Chloride EDP Series Three-Phase UPS (12-3000 kva): The EDP Series UPS is designed for commercial users who require versatility for today s application

More information

MASTER DIALOG ERM 8-20kVA three/single phase ERT kVA three/three phase

MASTER DIALOG ERM 8-20kVA three/single phase ERT kVA three/three phase MASTER DIALOG ERM 8-20kVA three/single phase ERT 10-160kVA three/three phase The Master Dialog range uses advanced double-conversion on-line (VFI) technology with a transformer isolated inverter output

More information

Single output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements.

Single output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements. RoHS Lead-Solder-Exemption Compliant New 3.3 V and 5 V Output Models Universal Input 85-264 VAC Industry-Standard Footprint: 7.0" x 4.3" x 1.97" (177.8 x 109.2 x 50.0 mm) Input Transient & ESD Compliance

More information

Digital High Resolution Display Technology. A New Way of Seeing Things.

Digital High Resolution Display Technology. A New Way of Seeing Things. R Digital High Resolution Display Technology A New Way of Seeing Things. Raytheon s Digital Display Digital Light Processing (DLP ) by Texas Instruments is a revolutionary new way to project and display

More information

Power Amplifier 1.5 MHz to 18 GHz, Split Bands. Now with smart digital monitoring and control options 19 Rack Mount Family Data Sheet

Power Amplifier 1.5 MHz to 18 GHz, Split Bands. Now with smart digital monitoring and control options 19 Rack Mount Family Data Sheet General Description: These are wideband CW / Pulse Power Amplifiers, designed for pulse operation, and general-purpose, amplification. Using an advanced high power density LDMOS and GaN semiconductor processes,

More information

Product Range Power Supplies

Product Range Power Supplies aschenbrenner a elektronik gmbh Product Range Power Supplies Aktualisiert 2018 / 04 Phone.: +49 (0) 8031-6506-0 www.aschenbrenner-elektronik.de DC / DC Power Supplies 12 V DC Output type numbers: 00791

More information

FN Series Scalable N+1 UPS 3kVA to 40kVA Tower

FN Series Scalable N+1 UPS 3kVA to 40kVA Tower FN Series Scalable N+ UPS kva to 0kVA Tower Advanced Features: * Parallel Units with a Single of up to 0kVA * True N+ Redundancy * ECO Mode: 97% Efficiency * DSP Double-Conversion On-line Sinewave Design

More information

N BTU/Hr Watt. N /8000 BTU/Hr. 1758/2344 Watt. N BTU/Hr Watt. Air Conditioners

N BTU/Hr Watt. N /8000 BTU/Hr. 1758/2344 Watt. N BTU/Hr Watt. Air Conditioners Spec-00732 F Sealed Enclosure Air Conditioners Sealed Enclosure Air Conditioners SPECTRACOOL Narrow Indoor/Outdoor N43 11000 BTU/Hr. 3223 Watt INDUSTRY STANDARDS N36 / BTU/Hr. / Watt N28 BTU/Hr. Watt UL/cUL

More information

1 Power Protection and Conditioning

1 Power Protection and Conditioning Power Protection and Conditioning MCR Hardwired Series Power Line Conditioning with Voltage Regulation The MCR Hardwired Series provides excellent noise filtering and surge protection to safeguard connected

More information

Modular Block Converter Systems

Modular Block Converter Systems Modular Block Converter Systems The Modular Block Converter System eliminates system downtime and maximizes ease of repair by providing fully modular systems for up conversion or down conversion. Critical

More information

Re-defining the utility-scale inverter

Re-defining the utility-scale inverter Re-defining the utility-scale inverter We believe in green energy in the ability to meet and contribute to growing power demand while supporting a smart grid that serves a smart society. Solution at a

More information

MAP110 AC-DC Series Data Sheet

MAP110 AC-DC Series Data Sheet Description Single-Output Model Selection VOLTAGE RANGE OUTPUT CURRENT OUTPUT CURRENT REGULATION REGULATION %p-p (NOTE 1) ACCURACY MAP110-1005 5V 4.95V to 5.50 16A 2 0.2% 1% 1% 5.09V to 5.11V MAP110-1012

More information

X-Band Redundant LNB Systems

X-Band Redundant LNB Systems X-Band Redundant LNB Systems BRX-1000 Series Introduction Redundant LNB systems minimize system downtime due to LNB failure by providing a spare LNB and an automatic means of switching to the spare upon

More information

Modular Power System acc. VG MoFess Module for Military Ground Vehicles

Modular Power System acc. VG MoFess Module for Military Ground Vehicles This new modular Power System for Military Ground Vehicles based on a standard box incorporating up to three different power modules. The power inlet module (230 V AC) includes line filter, lightning protection

More information

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter PSI-MOS-RS232/FO 850 E Serial to Fiber Converter perle.com/products/serial-fiber-converters/psi-mos-rs232-fo850e-rs232-to-fiber.shtml Connect RS232 devices to fiber optic cable Extend serial data up to

More information

Satellite Up- and Downconverter Indoor / Outdoor

Satellite Up- and Downconverter Indoor / Outdoor Visit us at www.work-microwave.de Satellite Up- and Downconverter Indoor / Outdoor Single / Dual / Triple Band Single / Dual Channel S-, C-, X-, Ku-, K (DBS)-, Ka-, and Q-band WORK Microwave s satellite

More information

Signal Conditioners. Highlights. Battery powered. Line powered. Multi-purpose. Modular-style. Multi-channel. Charge & impedance converters

Signal Conditioners. Highlights. Battery powered. Line powered. Multi-purpose. Modular-style. Multi-channel. Charge & impedance converters Signal Conditioners Highlights Battery powered Line powered Multi-purpose Modular-style Multi-channel Charge & impedance converters Industrial charge amplifiers & sensor simulators PCB Piezotronics, Inc.

More information

Stud Welding Equipment

Stud Welding Equipment Stud Welding Equipment 10/16 N550c Arc Charger Breakthrough Charger design provides powerful 550A Arc Welder from 120V wall outlet! The N550c Arc Charger is the first of a revolutionary new class of stud

More information

MAXTECH, Inc. BRC-1000 Series. C-Band Redundant LNB Systems. Technology for Communications. System Block Diagrams

MAXTECH, Inc. BRC-1000 Series. C-Band Redundant LNB Systems. Technology for Communications. System Block Diagrams MAXTECH, Inc. Technology for Communications BRC-1000 Series C-Band Redundant LNB Systems Introduction Redundant LNB systems minimize system downtime due to LNB failure by providing a spare LNB and an automatic

More information

XPert Filtered Balance Systems

XPert Filtered Balance Systems 8 FEATURES & BENEFITS Patented* XPert Filtered Balance Systems provide user protection by keeping powders and particulates contained during procedures involving powders. The built-in blower and exhaust

More information

Features. Specifications. Finish. Notes

Features. Specifications. Finish. Notes Spec-00732 BPH FX ( McLean Electronics Cooling Sealed Enclosure Cooling McLean Electronics Cooling: Sealed Enclosure Cooling SPECTRACOOL Narrow Indoor/Outdoor N43 11000 BTU/Hr. 3223 Watt N36 / BTU/Hr.

More information

MASTR II BASE STATION 12/24V POWER SUPPLY 19A149979P1-120 VOLT/60 Hz 19A149979P2-230 VOLT/50 Hz

MASTR II BASE STATION 12/24V POWER SUPPLY 19A149979P1-120 VOLT/60 Hz 19A149979P2-230 VOLT/50 Hz Mobile Communications MASTR II BASE STATION 12/24V POWER SUPPLY 19A149979P1-120 VOLT/60 Hz 19A149979P2-230 VOLT/50 Hz CAUTION THESE SERVICING INSTRUCTIONS ARE FOR USE BY QUALI- FIED PERSONNEL ONLY. TO

More information

T-Series Indoor/Outdoor Air Conditioners. Keeps its cool during peak heat loads and hot weather. Product Overview. T-Series A/C

T-Series Indoor/Outdoor Air Conditioners. Keeps its cool during peak heat loads and hot weather. Product Overview. T-Series A/C : Product Overview Keeps its cool during peak heat loads and hot weather A/C Indoor/Outdoor Air Conditioners Chapter Contents PRODUCT OVERVIEW T15 Model 800 BTU...43 Indoor/Outdoor Air Conditioners...42

More information

N43 N36 N28. Sealed Enclosure Cooling Air Conditioners

N43 N36 N28. Sealed Enclosure Cooling Air Conditioners SPECTRACOOL NARROW INDOOR/OUTDOOR N43 N36 N28 11000 BTU/Hr. / BTU/Hr. BTU/Hr. 3223 Watt / Watt Watt INDUSTRY STANDARDS UL/cUL Listed; Type 12, 3R, 4; 4X optional; File No. SA6453 CE IP 56 Internal Loop

More information

16W Ku-band Matchbox BUC

16W Ku-band Matchbox BUC 16W Ku-band Matchbox BUC MBB-KUS016 // MBB-KUE016 Field-Proven Performance Wavestream s Ku-band Matchbox Block Upconverter (BUC) offers unmatched efficiency and performance suitable for mobile SATCOM,

More information

Fibre Optic Modem ODW-622

Fibre Optic Modem ODW-622 Fibre Optic Modem ODW-622 RS-232 to fibre optic link, redundant ring or multidrop applications The ODW-622 can be used to create either redundant ring or multidrop solutions for devices with RS-232 interfaces.

More information

Fibre Optic Modem ODW-611

Fibre Optic Modem ODW-611 Fibre Optic Modem ODW-611 PROFIBUS DP to fibre optic link, point-to-point applications The ODW-611 is a fibre optic modem designed for point-to-point fibre optic connections between PROFI- BUS DP networks.

More information

TECHNICAL GUIDE 95.5% AFUE SINGLE STAGE RESIDENTIAL GAS FURNACES MULTI-POSITION MODELS: TG9S

TECHNICAL GUIDE 95.5% AFUE SINGLE STAGE RESIDENTIAL GAS FURNACES MULTI-POSITION MODELS: TG9S TECHNICAL GUIDE 95.5% AFUE SINGLE STAGE RESIDENTIAL GAS FURNACES MULTI-POSITION MODELS: TG9S NATURAL GAS 40-130 MBH INPUT Due to continuous product improvement, specifications are subject to change without

More information

Engineered to meet your needs T he oldest name in stud welding,

Engineered to meet your needs T he oldest name in stud welding, Engineered to meet your needs T he oldest name in stud welding, Nelson Stud Welding Inc., continues it s leadership role into the 21st century with the introduction of a full line of new drawn-arc welding

More information

Ku-Band Redundant LNB Systems

Ku-Band Redundant LNB Systems Ku-Band Redundant LNB Systems BRK-1000 Series Introduction Redundant LNB systems minimize system downtime due to LNB failure by providing a spare LNB and an automatic means of switching to the spare upon

More information

Synthesized Block Up- and Downconverter Indoor / Outdoor

Synthesized Block Up- and Downconverter Indoor / Outdoor Visit us at www.work-microwave.de Synthesized Block Up- and Downconverter Single / Dual / Triple Band Single / Dual Channel S-, C-, Ku-, K (DBS)-, Ka- and Q-band WORK Microwave s synthesized block converters

More information

Rack mounted telephone- and leased line modem for industrial applications

Rack mounted telephone- and leased line modem for industrial applications Rack mounted telephone- and leased line modem for industrial applications TR-6 Rack modem for industrial PSTNand /-wire leased line applications The TR-6 is an analogue V. 9 -rack PSTN modem as well as

More information

CR BTU/Hr. 469 Watt. CR and 4000 BTU/Hr. 791 and 1172 Watts CR & 8000 BTU/Hr and 2344 Watts.

CR BTU/Hr. 469 Watt. CR and 4000 BTU/Hr. 791 and 1172 Watts CR & 8000 BTU/Hr and 2344 Watts. 763.576.3200 Spec-00614 I763.422.2211 Sealed Enclosure Cooling Air Conditioners Sealed Enclosure Cooling Air Conditioners PROAIR Harsh Environment CR23 1600 BTU/Hr. 469 Watt CR29 2700 and 4000 BTU/Hr.

More information

C-Band Redundant LNB Systems

C-Band Redundant LNB Systems C-Band Redundant LNB Systems BRC-1000 Series Introduction Redundant LNB systems minimize system downtime due to LNB failure by providing a spare LNB and an automatic means of switching to the spare upon

More information

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit DATASHEET - S811+N66N3S Delivery program Soft starter, 66 A, 200-600 V AC, Us= 24 V DC, with control unit, Frame size N Part no. S811+N66N3S Catalog No. 168978 Eaton Catalog No. S811PLUSN66N3S EL-Nummer

More information

Model KT 53 Cooling incubators with thermoelectric cooling

Model KT 53 Cooling incubators with thermoelectric cooling Model KT 53 Cooling incubators with thermoelectric cooling The KT series combines outstanding performance with impressive energy efficiency and environmental friendliness. The cooled incubators of the

More information

P Output Ratings. Dimensions and Weights. Prime Rating

P Output Ratings. Dimensions and Weights. Prime Rating #DEALER_LOGO P275-5 #FGWILSON_GENSET_IMAGE Output Ratings Voltage, Frequency Prime Standby 400/230V, 50 Hz 480/277V, 60 Hz kva 250 275 kw 200 220 kva kw Ratings at 0.8 power factor. Please refer to the

More information

XR47-24 Models 24 W/ F (43 W/ C)

XR47-24 Models 24 W/ F (43 W/ C) 763.576.3200 Spec-00620 F763.422.2211 Cooling Sealed Enclosure Cooling Heat Exchangers Sealed Enclosure Cooling Heat Exchangers CLIMAGUARD Air-to-Air Indoor XR20 Models 4 W/ F (7 W/ C) XR29-08 Models 8

More information

P Output Ratings. Dimensions and Weights. Prime Rating

P Output Ratings. Dimensions and Weights. Prime Rating - P220-3 #FGWILSON_GENSET_IMAGE Output Ratings Voltage, Frequency Prime Standby 400V, 50 Hz 480V, 60 Hz kva 200 220 kw 160 176 kva - - kw - - Ratings at 0.8 power factor. Please refer to the output ratings

More information

T BTU/Hr Watts. T BTU/Hr Watts. Finish. Accessories. Options

T BTU/Hr Watts. T BTU/Hr Watts. Finish. Accessories. Options T-SERIES Mid-size Outdoor T29 4000 BTU/Hr. 1173 Watts T43, 8000, 10000 BTU/Hr., 2344, 2930 Watts T50 12000 BTU/Hr. 3516 Watts T53 19000 BTU/Hr. 5567 Watts Industry Standards UL/cUL Listed; Type 12, 3R,

More information

T BTU/Hr Watts

T BTU/Hr Watts 763.576.3200 Spec-00734 H763.422.2211 Sealed Enclosure Air Conditioners Sealed Enclosure Air Conditioners T-SERIES Mid-size Outdoor T29 4000 BTU/Hr. 1173 Watts T43, 8000, 10000 BTU/Hr., 2344, 2930 Watts

More information

PRELIMINARY Sunny Boy 240-US

PRELIMINARY Sunny Boy 240-US PRELIMINARY Sunny Boy 240-US SB 240-US-10 Optimized reliability Simple installation Unrivaled monitoring SMA-backed security Multigate technology allows for reduced component count Private band powerline

More information

P Output Ratings. Dimensions and Weights. Prime Rating

P Output Ratings. Dimensions and Weights. Prime Rating - P165-5 #FGWILSON_GENSET_IMAGE Output Ratings Voltage, Frequency Prime Standby 400V, 50 Hz 480V, 60 Hz kva 150 165 kw 120 132 kva 168.8 187.5 kw 135 150 Ratings at 0.8 power factor. Please refer to the

More information

P88-3. Output Ratings. Dimensions and Weights. Prime Rating

P88-3. Output Ratings. Dimensions and Weights. Prime Rating - P88-3 #FGWILSON_GENSET_IMAGE Output Ratings Voltage, Frequency Prime Standby 400V, 50 Hz 480V, 60 Hz kva 80 88 kw 64 70.4 kva 90 100 kw 72 80 Ratings at 0.8 power factor. Please refer to the output ratings

More information

P Output Ratings. Dimensions and Weights. Prime Rating

P Output Ratings. Dimensions and Weights. Prime Rating - #FGWILSON_GENSET_IMAGE Output Ratings Voltage, Frequency Prime Standby 400V, 50 Hz 480V, 60 Hz kva 150 165 kw 120 132 kva kw Ratings at 0.8 power factor. Please refer to the output ratings technical

More information

Fibre optic router for TP/FT-10 LRW-112PP

Fibre optic router for TP/FT-10 LRW-112PP Fibre optic router for TP/FT-10 LRW-112PP Lo n Wo r k s to fibre optic link, point-to-point applications The LRW-112PP router offers an easy way to extend the distance between LONWORKS 78 kbit/s TP/FT

More information

P Output Ratings. Dimensions and Weights. Prime Rating

P Output Ratings. Dimensions and Weights. Prime Rating #DEALER_LOGO P660-3 #FGWILSON_GENSET_IMAGE Output Ratings Voltage, Frequency Prime Standby 400/230V, 50 Hz 480/277V, 60 Hz kva 600 660 kw 480 528 kva kw Ratings at 0.8 power factor. Please refer to the

More information

P Output Ratings. Dimensions and Weights. Prime Rating

P Output Ratings. Dimensions and Weights. Prime Rating - P150-5 #FGWILSON_GENSET_IMAGE Output Ratings Voltage, Frequency Prime Standby 400V, 50 Hz 480V, 60 Hz kva 135 150 kw 108 120 kva 150 165 kw 120 132 Ratings at 0.8 power factor. Please refer to the output

More information

T BTU/Hr Watts

T BTU/Hr Watts T-SERIES Mid-size Outdoor T29 4000 BTU/Hr. 1173 Watts T43, 8000, 10000 BTU/Hr., 2344, 2930 Watts T50 12000 BTU/Hr. 3516 Watts T53 19000 BTU/Hr. 5567 Watts INDUSTRY STANDARDS UL/cUL Listed; Type 12, 3R,

More information

L-Band Block Up- and Downconverter Indoor / Outdoor

L-Band Block Up- and Downconverter Indoor / Outdoor Visit us at www.work-microwave.com L-Band Block Up- and Downconverter Single / Dual / Triple Band Single / Dual Channel S-, C-, X-, Ku-, K- (DBS), Ka-band (Q/V-band available on request) VSBU / VSBD Type

More information

P Output Ratings. Dimensions and Weights. Prime Rating

P Output Ratings. Dimensions and Weights. Prime Rating - #FGWILSON_GENSET_IMAGE Output Ratings Voltage, Frequency Prime Standby 400V, 50 Hz 480V, 60 Hz kva 180 200 kw 144 160 kva 200 218.8 kw 160 175 Ratings at 0.8 power factor. Please refer to the output

More information

Forced Convection Laboratory Ovens

Forced Convection Laboratory Ovens Forced Convection Laboratory Ovens Introducing Esco Isotherm - world class laboratory ovens from Esco for high-forced volume thermal convection applications such as drying and curing among many others.

More information

SAL Series Wireless Clock (V1)

SAL Series Wireless Clock (V1) SAL Series Wireless Clock (V1) HIGHLIGHTS Microprocessor based movement Each clock acts as a repeater and transmitter 915 928MHz frequency hopping technology Receiving and transmission rate every four

More information

P Output Ratings. Dimensions and Weights. Prime Rating

P Output Ratings. Dimensions and Weights. Prime Rating #DEALER_LOGO P400-3 #FGWILSON_GENSET_IMAGE Output Ratings Voltage, Frequency Prime Standby 400/230V, 50 Hz 480/277V, 60 Hz kva 350 400 kw 280 320 kva kw Ratings at 0.8 power factor. Please refer to the

More information

Model KT 115 Cooling incubators with thermoelectric cooling

Model KT 115 Cooling incubators with thermoelectric cooling Model KT 115 Cooling incubators with thermoelectric cooling The KT series combines outstanding performance with impressive energy efficiency and environmental friendliness. The cooled incubators of the

More information

SINAMICS G130 / G150. Line harmonics filter. Operating Instructions 05/2010 SINAMICS

SINAMICS G130 / G150. Line harmonics filter. Operating Instructions 05/2010 SINAMICS SINAMICS G130 / G150 Line harmonics filter Operating Instructions 05/2010 SINAMICS s Safety information 1 General 2 SINAMICS SINAMICS G130 / G150 Operating Instructions Mechanical installation 3 Electrical

More information

Model KT 53 Refrigerated incubators with thermoelectric refrigeration

Model KT 53 Refrigerated incubators with thermoelectric refrigeration Model KT 53 Refrigerated incubators with thermoelectric refrigeration The KT series combines outstanding performance with impressive energy efficiency and environmental friendliness. The refrigerated incubators

More information

P65-5. Output Ratings. Dimensions and Weights. Prime Rating

P65-5. Output Ratings. Dimensions and Weights. Prime Rating - P65-5 #FGWILSON_GENSET_IMAGE Output Ratings Voltage, Frequency Prime Standby 400V, 50 Hz 480V, 60 Hz kva 60 65 kw 48 52 kva 68.8 75 kw 55 60 Ratings at 0.8 power factor. Please refer to the output ratings

More information

User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W

User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W Entry Line Fast Ethernet Switch Fast Ethernet Switch with PoE+ for Industrial Use Page

More information

Synthesized Block Up- and Downconverter

Synthesized Block Up- and Downconverter Visit us at www.w ork-microw ave.de Synthesized Block Up- and Downconverter S, C, X, Ku, K, The satellite up- and downconverters developed and manufactured by WORK Microwave are designed to meet the requirements

More information

SITOP power supply. Technical data, April SITOP Power Supply. Answers for industry.

SITOP power supply. Technical data, April SITOP Power Supply. Answers for industry. SITOP power supply Technical data, April 2010 SITOP Power Supply Answers for industry. SITOP reliable power supply Efficient operation of a machine or plant requires a reliable, constant power supply.

More information

ODW-621. RS-232 Point-to-point applications

ODW-621. RS-232 Point-to-point applications Re-timing Data rate up to 250 kbit/s 9-position D-sub connector Redundant power supply inputs Status interface for fault indication Fibre link fault indication (Red) Design for harsh environments 40 to

More information

T BTU/Hr Watts

T BTU/Hr Watts T-SERIES LARGE CAPACITY OUTDOOR T62 20000 BTU/Hr. 5860 Watts T70-36 36000 BTU/Hr. 10548 Watts T70-60 59000 BTU/Hr. 17287 Watts INDUSTRY STANDARDS UL/cUL Listed; Type 12, 3R, 4; 4X optional; File No. SA6453

More information

Power Transformers & High Frequency Magnetics Your one source for all your magnetics needs!

Power Transformers & High Frequency Magnetics Your one source for all your magnetics needs! www.signaltransformer.com Power Transformers & High Frequency Magnetics Your one source for all your magnetics needs! Audio Battery Chargers Communication Dental Equipment Elevator Controls Fire & Safety

More information

Series CT7N Bimetallic Overload Relays

Series CT7N Bimetallic Overload Relays Series CT7N imetallic Overload Relays Choose CT7N overloads in DC applications and when monitoring Variable Frequency Drives Sprecher + Schuh has always paid particular attention to the subject of motor

More information

Ratings at 0.8 power factor. Please refer to the output ratings technical data section for specific generator set outputs per voltage.

Ratings at 0.8 power factor. Please refer to the output ratings technical data section for specific generator set outputs per voltage. - P2000/P2250E #FGWILSON_GENSET_IMAGE Output Ratings Voltage, Frequency Prime Standby 400V, 50 Hz 480V, 60 Hz kva 2000 2250 kw 1600 1800 kva kw Ratings at 0.8 power factor. Please refer to the output ratings

More information

P1000P1/P1100E1 50Hz

P1000P1/P1100E1 50Hz - P1000P1/P1100E1 50Hz #FGWILSON_GENSET_IMAGE Output Ratings Voltage, Frequency Prime Standby 400V, 50 Hz 480V, 60 Hz kva 1000 1100 kw 800 880 kva kw Ratings at 0.8 power factor. Please refer to the output

More information

P550-3L. Output Ratings. Dimensions and Weights. Prime Rating

P550-3L. Output Ratings. Dimensions and Weights. Prime Rating - P550-3L Optional LS Upgrade #FGWILSON_GENSET_IMAGE Output Ratings Voltage, Frequency 400V, 50 Hz 480V, 60 Hz Prime Standby kva 500 550 kw 400 440 kva kw Ratings at 0.8 power factor. Please refer to the

More information

P800P1/P900E1. Output Ratings. Dimensions and Weights. Prime Rating

P800P1/P900E1. Output Ratings. Dimensions and Weights. Prime Rating #DEALER_LOGO P800P1/P900E1 #FGWILSON_GENSET_IMAGE Output Ratings Voltage, Frequency Prime Standby 400/230V, 50 Hz 480/277V, 60 Hz kva 800 900 kw 640 720 kva 844 938 kw 675.2 750.4 Ratings at 0.8 power

More information

R&S FK2900M HF Antenna Tuning Unit For stationary and shipboard applications

R&S FK2900M HF Antenna Tuning Unit For stationary and shipboard applications Secure Communications Product Brochure 05.00 R&S FK2900M HF Antenna Tuning Unit For stationary and shipboard applications R&S FK2900M HF Antenna Tuning Unit At a glance The R&S FK2900M is an antenna tuning

More information

SPECIAL SPECIFICATION 6735 Video Optical Transceiver

SPECIAL SPECIFICATION 6735 Video Optical Transceiver 2004 Specifications CSJ 0924-06-244 SPECIAL SPECIFICATION 6735 Video Optical Transceiver 1. Description. This Item governs the furnishing and installation of Video optical transceiver (VOTR) in field location(s)

More information

P1350P1/P1500E1 50Hz

P1350P1/P1500E1 50Hz - P1350P1/P1500E1 50Hz #FGWILSON_GENSET_IMAGE Output Ratings Voltage, Frequency Prime Standby 400V, 50 Hz 480V, 60 Hz kva 1350 1500 kw 1080 1200 kva kw Ratings at 0.8 power factor. Please refer to the

More information

LONWORKS Fibre Optic Converter

LONWORKS Fibre Optic Converter LONWORKS Fiber Optic Converter LRW-102 and LRW-102/PP LONWORKS to fibre optic link, multidrop and redundant ring applications The LRW-102 is a fibre optic modem designed for multidrop and redundant ring

More information

Multiple Band Outdoor Block Up- and Downconverters

Multiple Band Outdoor Block Up- and Downconverters Multiple Band Outdoor Block Up- and Downconverters Vertical Mount Option RF IF LO Frequency Frequency Frequency Model Band (GHz) (MHz) (GHz) Number Block Upconverters 1 12.75 13.25 0.95 1.45 11.8 UPB2-WS-13.625

More information

P400-3L. Output Ratings. Dimensions and Weights. Prime Rating

P400-3L. Output Ratings. Dimensions and Weights. Prime Rating - P400-3L Optional LS Upgrade #FGWILSON_GENSET_IMAGE Output Ratings Voltage, Frequency 400V, 50 Hz 480V, 60 Hz Prime Standby kva 350 400 kw 280 320 kva kw Ratings at 0.8 power factor. Please refer to the

More information

GENESIS Indoor Air Conditioners

GENESIS Indoor Air Conditioners Product Overview : Indoor Air Conditioners M28 Model M52 460 Volt 3-Phase Model M17 Model 68 68 Product Overview : The specifier s choice for cooling industrial process controls Indoor Air Conditioners

More information

FREQUENCY CONVERTER 1/3 RACK-MOUNTED BLOCK CONVERTER. Narda-MITEQ FEATURES OPTIONS. Unit shown with Option 17. Unit shown without Option 17

FREQUENCY CONVERTER 1/3 RACK-MOUNTED BLOCK CONVERTER. Narda-MITEQ FEATURES OPTIONS. Unit shown with Option 17. Unit shown without Option 17 1/3 RACK-MOUNTED BLOCK CONVERTER Unit shown with Option 17 Unit shown without Option 17 FEATURES Automatic 5/10 MHz internal/external reference selection with a 0.1 Hz nominal bandwidth clean-up loop Gain

More information

Operating Instructions 07/2007 Edition. SINAMICS G130/G150 Line harmonics filter. sinamics

Operating Instructions 07/2007 Edition. SINAMICS G130/G150 Line harmonics filter. sinamics Operating Instructions 07/2007 Edition SINAMICS G130/G150 Line harmonics filter sinamics s Safety information 1 General 2 SINAMICS SINAMICS G130/G150 Operating Instructions Mechanical installation 3 Electrical

More information

Direct PWM. 1000/2000 Series POWERBLOK MODULE

Direct PWM. 1000/2000 Series POWERBLOK MODULE Direct PWM 1000/2000 Series POWERBLOK MODULE Features A universal servo-drive integrated on a Power Hybrid Module. Designed for direct PWM Servo Control Designed for use with Deta Tau's PMAC controllers

More information

Hitachi Kokusai Electric Comark LLC

Hitachi Kokusai Electric Comark LLC Hitachi Kokusai Electric Comark LLC TRANSMIT TER OF THE FUTURE Solid State. Broadband. Affordable. The future has arrived. With rapid changes in solid state RF device technologies and design techniques,

More information

SCALE & WEIGHT DISPLAYS

SCALE & WEIGHT DISPLAYS The MICRO SERIES SCALE & WEIGHT DISPLAYS LARGE DIGIT MODELS Mighty-5S DPM MODELS Micro-S & Mighty-1S Mighty-1S Micro-S ELECTRO-NUMERICS, INC. Introduction The Electro-Numerics family of Digital Panel Meters

More information

MCR3 POWER EQUIPMENT. Microprocessor Controlled Constant Current Regulator. Compliance with Standards. Uses. Features

MCR3 POWER EQUIPMENT. Microprocessor Controlled Constant Current Regulator. Compliance with Standards. Uses. Features Microprocessor Controlled Constant Current Regulator Compliance with Standards FAA: ICAO: IEC: 61822 CENELEC: AC 150/5345-10 (current edition), L-828, L-829. Aerodrome Design Manual Part 5, para. 3.2 (current

More information

Ku-Band Redundant LNB Systems. 1:1 System RF IN (WR75) TEST IN -40 db OFFLINE IN CONTROLLER. 1:2 System POL 1 IN (WR75) TEST IN -40 db POL 2 IN

Ku-Band Redundant LNB Systems. 1:1 System RF IN (WR75) TEST IN -40 db OFFLINE IN CONTROLLER. 1:2 System POL 1 IN (WR75) TEST IN -40 db POL 2 IN BRK-1000 Series Ku-Band Redundant LNB Systems Introduction Redundant LNB systems minimize system downtime due to LNB failure by providing a spare LNB and an automatic means of switching to the spare upon

More information

Agilent High Capacity RV Pumps & Roots Pumping Systems

Agilent High Capacity RV Pumps & Roots Pumping Systems Agilent High Capacity RV Pumps & Roots Pumping Systems 2-3 MS-Series Rotary Vane Pumps 4-5 RPS-Series Roots Pumping Systems and RPK-Series Roots Pumping Kits 6-7 Typical Applications 8-15 Pump Models MS-Series

More information

GENESIS Indoor Air Conditioners

GENESIS Indoor Air Conditioners PH FX ( Product Overview : Indoor Air Conditioners M28 Model M52 460 Volt 3-Phase Model M17 Model 74 74 Product Overview : The specifier s choice for cooling industrial process controls Indoor Air Conditioners

More information

TX33 Models 28 W/ F (50 W/ C) TX23 Models 14 W/ F (25 W/ C) TX38 Models 56 W/ F (100 W/ C) TX52 Models 83 W/ F (150 W/ C)

TX33 Models 28 W/ F (50 W/ C) TX23 Models 14 W/ F (25 W/ C) TX38 Models 56 W/ F (100 W/ C) TX52 Models 83 W/ F (150 W/ C) CLIMAGUARD Air-to-Air Outdoor TX23 Models 14 W/ F (25 W/ C) TX33 Models 28 W/ F (50 W/ C) TX38 Models 56 W/ F (100 W/ C) TX52 Models 83 W/ F (150 W/ C) INDUSTRY STANDARDS ; Type 12, 4; 4X optional; File

More information

SPECIAL SPECIFICATION 1987 Single Mode Fiber Optic Video Transmission Equipment

SPECIAL SPECIFICATION 1987 Single Mode Fiber Optic Video Transmission Equipment 1993 Specifications CSJ 0027-12-086, etc. SPECIAL SPECIFICATION 1987 Single Mode Fiber Optic Video Transmission Equipment 1. Description. This Item shall govern for the furnishing and installation of color

More information

USER MANUAL. 27 Full HD Widescreen LED Monitor L270E

USER MANUAL. 27 Full HD Widescreen LED Monitor L270E USER MANUAL 27 Full HD Widescreen LED Monitor L270E TABLE OF CONTENTS 1 Getting Started 2 Control Panel/ Back Panel 3 On Screen Display 4 Technical Specs 5 Care & Maintenance 6 Troubleshooting 7 Safety

More information

Ka-Band Outdoor Block Upconverters and Low-Noise Block Downconverters

Ka-Band Outdoor Block Upconverters and Low-Noise Block Downconverters R Back to Block/Fixed Tuned Converters Ka-Band Outdoor Block Upconverters and Low-Noise Block Downconverters Ka-BAND OUTDOOR BLOCK AND LOW-NOISE BLOCK Specifications Options Outline Drawings Phase Noise

More information

FREQUENCY CONVERTER. MULTIPLE OUTPUT WIDEBAND Ku AND Ka DOWNCONVERTERS. Narda-MITEQ FEATURES OPTIONS

FREQUENCY CONVERTER. MULTIPLE OUTPUT WIDEBAND Ku AND Ka DOWNCONVERTERS. Narda-MITEQ FEATURES OPTIONS MULTIPLE OUTPUT WIDEBAND Ku AND Ka DOWNCONVERTERS FEATURES Small weather resistant enclosure Automatic 5/10 MHz internal/external reference selection 10/100 Base-T Ethernet and RS-485/RS-422 remote control

More information

Thermo Scientific Revco PLUS Ultra-Low Temperature Chest Freezers. Maximizing Critical Sample Protection and Storage

Thermo Scientific Revco PLUS Ultra-Low Temperature Chest Freezers. Maximizing Critical Sample Protection and Storage Thermo Scientific Revco PLUS Ultra-Low Temperature Chest Freezers Maximizing Critical Sample Protection and Storage 1 Safeguarding your precious samples with advanced technology and exceptional quality

More information

1/3 RACK-MOUNTED BLOCK CONVERTERS

1/3 RACK-MOUNTED BLOCK CONVERTERS AMPLITUDE SLOPE CONTROL Unit shown with option 17 Unit shown without option 17 FEATURES Automatic 5/10 MHz internal/external reference selection with a 0.1 Hz nominal bandwidth clean-up loop Gain control

More information

Model KBF 115 Constant climate chambers with large temperature / humidity range

Model KBF 115 Constant climate chambers with large temperature / humidity range Model KBF 115 Constant climate chambers with large temperature / humidity range The BINDER KBF is the specialist for unconditionally reliable stability testing and precise maintenance of constant climate

More information

ULTRALOW TEMPERATURE FREEZERS -86 C

ULTRALOW TEMPERATURE FREEZERS -86 C ULTRALOW TEMPERATURE FREEZERS -86 C NUAIRE MEANS ENVIRONMENTALLY SAFE Laboratory professionals the world over depend on NuAire for safe, reliable laboratory equipment that lasts longer and performs better

More information

Model CB 60 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

Model CB 60 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor Model CB 60 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor The BINDER CB series CO 2 incubator is the premium class among the CO 2 incubators. It is suitable for all sensitive

More information

Magnecraft Power Relays

Magnecraft Power Relays Description DPST-NO, 30 A; DPDT, 30 A (NO) / 3 A (NC) Description The series power relays offer a small package size and features Class F insulation for a maximum coil temperature of 55 C (3 F). These

More information

Model # of Colors Colors Input Connection 1 K90TLGRPQ 2 Green, Red K90TLGYRPQ 3 Green, Red, Yellow K90TLBGYRPQ 4 Blue, Green, Yellow, Red

Model # of Colors Colors Input Connection 1 K90TLGRPQ 2 Green, Red K90TLGYRPQ 3 Green, Red, Yellow K90TLBGYRPQ 4 Blue, Green, Yellow, Red Datasheet Large Multicolor that Alternates Between Active Inputs Bright, uniform indicator light Alternates between colors when multiple inputs are active Models are available with up to five colors in

More information

Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features

Panel cutout required: 1.772 x 3.622 (45mm x 92mm) 1.76 (45mm) 2.45 (62mm) 3.20 (81mm) 3.60 (91mm) 0.59 (15mm) Special Features NEMA4X, IP65 Front Bezel Meter with Relays Option RELAY2 RELAY1 24V OUT POWER 4 3 2 1 6 5 2 1 2 1 NO NC COM NO NC COM RTD TC P P RTD 3 4 1 2 5 TC 6 SWITCH Rear View Gasket APM765 Panel Meter Description

More information