1 IMPROVING MAN-MACHINE INTERACTION IN CONTROL CENTERS: THE IMPORTANCE OF A FULL-GRAPHICS INTERFACE A. Almeida.do Vale M. J. Dias Gongalves Zita A. Vale Member,IEEE University of Porto/Faculty of Engineering Department of Electrical and Computer Engineering Rua dos Bragas Porto Codex - Portugal Phone: Fax: Telex: FEUP P zav@garfield.fe.up.pt KEYWORDS: SCADA/EMS Hardware Implementation and Design, User Interface, Full-Graphics Displays ABSTRACT - Control Centers are responsible for the control, supervision and monitoring of Power Systems. It is of primary importance that the software existing in Control Centers provides operators with the most important, recent and correct information about the state of the system. The use of semi-graphic consoles proved to be insufficient for this kind of tasks. In this paper we present a multi window system with zooming facilities in a full-graphics environment. This system helps operators providing them with the information they need in a more concise and friendly way. Some examples concerning the Portuguese Electrical Network are presented. Future improvements discussed. in this application are!.introduction Nowadays, Electric Power Systems are remotly controlled from Control Centers. These centers usually control a Power System extending through a large geographic area and including some tens of substations. In order to provide an efficient and real-time control, Control Centers must have access to a large volume of information about the state of the Power System. This information is acquired in measuring points installed all over the electrical network and transmitted to Control Centers using telecommunication systems. The whole system is usually known as a SCADA (Supervisory Control and Data Acquisition System) [ 1). The increasing complexity of Power Systems and the aim of delivering high quality electrical energy at minimum costs make Control Center operator tasks highly demanding. 'Control Centers include complex computerized applications but human operators still play the most important role in identifying problems and taking decisions. Recent experience has shown that, specially in emergency situations, the interpretation of the displayed information is a difficult task even for experienced and well-trained operators. In fact, man-machine interfaces used in today's Control Centers provide operators with great amounts of information, without taking into account human limitations. The main factors that contribute to the incompatibility between the system and operators are: the great amount of information displayed at the same time without any filtering, the incapacity of the graphics displays of showing at the same time information of generic and specific level, and the non-existence of a general representation of the entire Electrical Network in the library of graphic images. The solution for this kind of problems includes the use of a multi-window system with zooming facilities in a full-graphics environment in SCADA implementation and design. This must be supported by good knowledge about Control Center operators needs and with optimum control of the displayed information. This will help operators in receiving the most important information about the Electrical Network in order to take the most appropriate actions. This paper presents a software package that is being developed at the University of Porto, using c language in a "Decsystem 5500 RISC - Digital" with graphic support of a color high 273

2 resolution X terminal "Tektronics". This software is designed to Portuguese Control Centers. alter the existing ones or to treat a different network. The new Portuguese Control System has been installed between May 1988 and February The system is hierarchic and includes the National Control Center (NCC) at the top level, two Subestation Operation Centers (SOC) at Vermoim and Sacavem and four Hydroplant Control Centers (HCC). The National Control Center uses two machines VAX 8600 with 3 semi-graphic consoles with a total of 7 video displays. The use of this kind of display does not allow a friendly manmachine interface. In our system the operator can easily get information, of generic and specific level, in the same display, due to the possibility of opening different windows for displaying information. The most important information is displayed in the screen with top priority, on the other hand the less important information can be accessed only by operators demand. It provides an image of the whole Portuguese electrical network. This image includes information about topology and alarms that is continuously updated according to data that is acquired in the Power System and transmitted to Control Centers. The main goal of this screen is to provide dispatchers with general information about the whole network. On the other hand, it identifies the areas of the network that are causing the generation of alarms. Under request, operators can easily access more detailed information about a specific area (zoom view) of the network and a specific plant, without loosing a general view of the entire network. Our software prov.ides, as the conventional user interfaces, the electrical diagram of each plant. Besides this, it includes a set of new possibilities such as small windows displaying information about typical load diagrams, or about each equipment (electric and mechanic characteristics, faults,.. ). This system includes a drawing tool, built in the same environment, that allows operators to build, expand or alter graphic images without any programming effort. This facility may be used when is necessary to include new plants, 2. USER INTERFACE - AN OPEN SUBJECT The great evolution in computer hardware, made it possible to process great volumes of information in very short periods of time. However human abilities have not increased that much and some computer applications do not respect human limitations [2]. This gap between computer and human abilities is today widely recognized and research works concerning human and computer interaction are becoming more and more important [3]. In our opinion, the design of the User Interface (UI) of computer applications, should not be treated in the restricted limits of displays design. In fact, the design of the UI involves mainly two different questions: a) what information is to be displayed b) how will that information be displayed Both questions have equal importance and neglecting one of them makes effort involved in the other. useless the Answering question a) involves a deep understanding of the problems being treated. Artificial Intelligence techniques are presently used for this purpose [4]. Question b) concerns directly the building of the displays to be presented to operators and is still an open question. Considering that the way in what information is presented determines how useful it will be, the UI must be regarded as a crucial aspect of any computer application. The UI is obviously even more important in the case of real-time applications as the ones installed in Control Centers. In case of an accident, decisions must be based on different kinds of information and be taken as quickly as possible. In these situations, a good UI is of great help to operators. The use of full-graphics displays presents a wide range of new possibilities to the UI of Energy Management Systems (EMS) and SCADA. As these application are very complex and expensive, electrical utilities must carefully decide on the use of full-graphics technology in their EMS [5,6]. 274

3 Full-graphics technology allows to introduce a set of new facilities: multi-window systems, scroll windows, zooming and panning, extensive use of menus and buttons actuated through the use of the mouse. This is specially important because of the flexibility that can be reached using this facilities. Using this technology, operators can access different levels of information at the same time in a very friendly and flexible way. The use of full-graphics displays in the UI of an EMS must however consider some particular aspects of this application. It is important to use the new possibilities only when they constitute a real improvement to the UI. Some of them, that seem very attractive at the first sight, proved not to be well accepted by operators. In particular, operators do not seem to like to work with a lot of windows with resizing and dragging possibilities [5]. Moreover, window manipulation increases the time response in case of emergency situations. The optimal solution is a multi-window system where window manipulation is controlled by the application itself and by operators. This has also the advantage of providing. an easier management of the displayed information ("obliging" operators to see the most important information). In general, full-graphics create a new philosophy technology may of displaying information: - a great volume and variety of additional information is ready to be displayed, on operator's demand - zooming and panning provide easy and flexible access to the available information - analog values are used to construct graphics (lines, bars, pie charts) showing, at a glance, the most important information - icons (to be clicked on) are used to have direct and quick access to more detailed information about the objects they represent. Colors [6,7] are still a very important means of providing and reinforcing information. Its use is of special importance in the following situations : indication of device status - differentiation of voltage levels (e.g. in transmission lines) - indication of severity of alarms - helping in the interpretation of graphics. Till now we have only addressed the use of full-graphics displays for an overall renovation of Control Centers [6,8]. However, this technology has a much more immediate application in the existing Control Centers, in the case of new appended applications [4]. In fact, a new application (e.g. a Knowledge Based System) can be appended to the existing EMS, running in a different machine communicating with the main computer through a Local Area Network (LAN). In these cases, the machine used for the new application is usually a workstation providing a fullgraphics UI. 3. SYSTEM OVERVIEW The application that is being presented in this paper, has been developed using C Language in a Decsystem 5500 RISC-DIGITAL, with a graphic support of a color high resolution X terminal. It was implemented with the aid of the XWindows programming libraries, and permits the simulation and the building of a electrical network representation for future control and supervising. The Main Display of the application includes three subwindows with the following contents: - Mapboard window containing a graphic representation of the entire electrical network (Synoptic Board) - Menu window containing a wide variety of menus, specially used for the building of the different zoom views, electrical diagrams of the plants and the mapboard - Zoom window were the zoom views are displayed. The program has two entirely different ways of operation. The first one is used for building the different plant diagrams. The second is the user interface application, intended to use in real-time operation Display Building When the program starts, a menu window is displayed in the bottom right corner of the main window, that allows operator to build new diagrams and expand the existing ones. There are three types of diagrams that can be 275

4 modified or created: - the mapboard the zoom windows - the plant diagram windows. For this kind of operation, the user only has to press the mouse button in the desired menu button Mapboard building The different building options within this application are : - inclusion of the different plants in the mapboard. - inclusion of the different lines connecting the plants in the synoptic board. The menu concerning the inclusion of the plants is shown in figure 1. ~ - Substation 1~1- Thermal power plant Green - Green line (220 kv) Blue - Blue line (150 kv) Black - Black line (60 kv) Figure 2 - Building lines The procedure for including new lines is very simple being only necessary to choose the density, color, and location by pressing the mouse button in the desired places. The program detects automatically the name of a plant when an extremity of the line is selected. While the user is including new lines, a text file named "LINHAS.MJG" is being updated Zoom building : The program gives to the operator the possibility to build the different zoom zones existing in the screen. For this kind of action it must be selected from the initial menu the option "Zoom". Then it will be presented a second menu named "Building Zoom". The format of the specified menu is as shown below in figure 3. 1~1- Hydro power plant ] "Building Lines" menu ~- "Building Plant Diagrams" menu Figure 1 - Building window As the operator is including in the board the new plants, a text file named "PORTINST.MJG" is being updated. If the operator wants to include new lines in the synoptic board it is necessary to select the option "Lines" and a new menu is displayed (see figure 2). 0 - Substation in small size 00 [ll] ~ - Substation in large size - Hydro power plant - Thermal power plant - Plant - Includes the name of the station I~ - Menu for including the different lines interconnecting all the plants Figure 3 - Building zoom Q - Line of small density B- Line of medium density ~ - Line of large density Red - Red line (400 kv) The procedure for building the zoom images is very simple and it is only necessary to select with the mouse the plants to install and its location in the zoom window. There are essentially three steps to build the image: - choose the type of plant to include - choose the desired place to display the 276

5 in the zoom window - select "Plant" to include the name of the plant. The program displays upon the zoom window a grid to help the selection of the desired place in the image to build. A image reporting this stage of building a zoom window is show below in figure 4. ~ to indicate that the line to include starts and ends in a plant existing in the zoom view [J) to include terminals located in vertical way Q to include terminals located in a horizontal way Define Area is used to select the upper left corner and the right bottom. While the zoom and the lines are being inserted in the screen, two files are being updated ( "ZOOM.MJG" and "ZOOMLI.MJG"). Figure 4 - Building a zoom window When the image is completed in terms of the plants existing in that zoom area, the user can easily include the different lines that interconnect the plants. When the referred option is selected, a new menu, called "Building Zoom lines " is displayed, having the aspect shown in figure 5. Figure 5 - Building zoom lines This menu includes the following buttons: - Four zones corresponding to four different color lines (different voltage levels) - Start button to initiate the building of a new line in the zoom window - End button to terminate the building of a new line l!5ji to indicate that the line to include starts in a plant existing in the zoom view and ends in a plant not existing in the zoom view Plant diagram building : The other kind of images that the program displays is the electric diagram of the plants. The operator can easily build this diagrams needing only to choose in the first menu the option corresponding to this item. Then a new window is opened showing the plant diagram to alter or a white window to bui 1 t another plant diagram. The menu provided to the user to build this kind of diagrams has the following items: - generator - transformer (Two-winding) - auto-transformer (Up and Down position) - circuit breaker - disconnecter - busbar - line - bypass disconnecter - interbar - small characters to include panels numbers and line names - large characters to include device numbers, voltage levels and titles for the stations - possibility to clear a already included symbol - save option to include the name of the built plant. An example of a plant diagram built with this application can be found in figure

6 or equivalent device, if it is installed (track ball). Figure Normal operation :1, [ I Plant diagram The other way of using this application is to use the different images built as it was described before, to control, supervise and interact with an electrical network. In normal operation the main display of the application has the aspect displayed in figure 7. The only device that operators must use to easily and rapidly access to the different images of the controlled network is the mouse In the mapboard (the principal area where the actions are taken) there are hot spots that correspond to the plants and zoom areas. Dispatchers experience shows that the names of the different plants are easily memorized after a short period of intense use and interface with the controlled network. Due to this aspect the mapboard in this application does not show the name of each plant, but only the corresponding symbol included in its geographic location. The operator can access this information only by pressing the left button of the mouse over the desired plant symbol. The name is immediately displayed in a small window displayed in the right bottom corner of the mapboard window. To get more detailed information, the user must press the center button of the mouse to display a zoom image of the selected area. The aspect of a zooming operation is shown in figure 7. It can be observed that the selected zoom area is marked in the synoptic board with a rectangle. In this zoom window the operator can have a different level of information without loosing the image of the entire V /CCL3 srn/s\ic2 Figure 7 - Main display window 278

7 network, what was not possible in the non full-graphic displays. This application also provides operators with the display of plant diagrams. To display this type of information it is only necessary to press the right button of the mouse above the desired station in the mapboard. Immediately a graphic window is displayed showing a complete description of the plant diagram. An example showing this type of images is presented in figure 6 (Vermoim substation). 4. CONCLUSIONS The User Interface is presently accepted to be a very important factor for the success of a computer application. Together with Knowledge Based Systems, a full-graphics based interface can help Control Center operators in performing their tasks in an efficient and more friendly way. In this paper, we presented a software package, based on XWindows, that provides a very friendly and flexible User Interface for Control Centers. This package includes applications for building, with minimum effort, the displays to be used in real operation. The principal characteristic of the application presented is the great simplicity of the files that include the different graphic images (text files) and the great facility of integration in a more extended software package of EMS/SCADA hardware design. 3) 4) 5) 6) 7) 8) c. Weisang and K. Zinser, "Graphics and Knowledge-Based Operator Support", The Second International Forum on Expert Systems and Computer Simulation in Energy Engineering, Erlangen, Germany, pp; , March 17-20, 1992 z. A. Vale and A. M. Moura, "An Expert System with Temporal Reasoning for Alarm Processing in Power System Control Centers", 92 SM 602-3, IEEE Power Engineering Society 1992 Summer Meeting, Seattle, U.S.A, July 12-16, 1992 S. Clark, J. Steventon and R. Masiello, "Full-Graphics Man-Machine Interface for Power System Control Centers", IEEE Computer Applications in Power, Vol. 1, No. 3, pp , July 1988 J. Young, T. Green and T. Desmond, "Building Quality Full-Graphics Displays", IEEE Computer Applications in Power, Vol. 5, No. 2, pp , April 1992 K. Imhof and c. Arias, "Show it with Colors. Connectivity, Status, and Value Information in Energy Management Systems", IEEE Computer Applications in Power, Vol. 3, No. 4, pp , October 1990 E. Euxibie, P. Jourdin, P. Audousset and F. Audrain, "A New Alarm Processing for the Forthcoming National Control System of Electricite De France", The third IEE International Conference on Power System Monitoring and Control, London, United Kingdom, REFERENCES 1) W. Ackerman and w. Block, "Understanding Supervisory Systems", IEEE Computer Applications in Power, Vol. 5, No. 4, pp , October ) Zita A. Vale and A. Machado e Moura, "An Expert System to Assist Operators of the Power System Control Centres", Information-Decision-Action Systems in Complex Organisations, Oxford, United Kingdom, IEE Conference Publication No. 353, pp , 6-8 April, 1992 This work is partially sponsored by JNICT (The National Institute for Scientific Research). 279

Visualization and Human Factors in Electric Power System Operation

Visualization and Human Factors in Electric Power System Operation Visualization and Human Factors in Electric Power System Operation Sushil Kumar Soonee, Devendra Kumar, Samir Chandra Saxena and Sunil Kumar Abstract--Optimal and effective operation of a large power system

More information

HARMONIZATION OF SYNOPTIC BLOCK DIAGRAMS ON THE CONTROL PANELS OF MV SWITCHGEAR AND CONTROLGEAR

HARMONIZATION OF SYNOPTIC BLOCK DIAGRAMS ON THE CONTROL PANELS OF MV SWITCHGEAR AND CONTROLGEAR HARMONIZATION OF SYNOPTIC BLOCK DIAGRAMS ON THE CONTROL PANELS OF MV SWITCHGEAR AND CONTROLGEAR Yvan L. Tits ELECTRABEL 8, Boulevard du Régent, B-1000 Brussels (Belgium) Tel: +32 2 518 62 66 - Fax: +32

More information

Specification. NGTS Issue 1 October 1993

Specification. NGTS Issue 1 October 1993 The Electrical Standards for SHE Transmission s area are non-maintained versions of National Grid Technical Specifications that are applicable to the SHE Transmission System only. These specific versions

More information

ADS Basic Automation solutions for the lighting industry

ADS Basic Automation solutions for the lighting industry ADS Basic Automation solutions for the lighting industry Rethinking productivity means continuously making full use of all opportunities. The increasing intensity of the competition, saturated markets,

More information

Quick Reference Manual

Quick Reference Manual Quick Reference Manual V1.0 1 Contents 1.0 PRODUCT INTRODUCTION...3 2.0 SYSTEM REQUIREMENTS...5 3.0 INSTALLING PDF-D FLEXRAY PROTOCOL ANALYSIS SOFTWARE...5 4.0 CONNECTING TO AN OSCILLOSCOPE...6 5.0 CONFIGURE

More information

Software Quick Manual

Software Quick Manual XX177-24-00 Virtual Matrix Display Controller Quick Manual Vicon Industries Inc. does not warrant that the functions contained in this equipment will meet your requirements or that the operation will be

More information

Grid Interactive Advanced Features Self-Supply Mode

Grid Interactive Advanced Features Self-Supply Mode Grid Interactive Advanced Features Self-Supply Mode CHILICON POWER MICROINVERTERS AND CP-100 CORTEX GATEWAY SYSTEM OVERVIEW Chilicon Power Advanced Inverter functions Power Factor Control: -0.8 to +0.8

More information

Interactive Virtual Laboratory for Distance Education in Nuclear Engineering. Abstract

Interactive Virtual Laboratory for Distance Education in Nuclear Engineering. Abstract Interactive Virtual Laboratory for Distance Education in Nuclear Engineering Prashant Jain, James Stubbins and Rizwan Uddin Department of Nuclear, Plasma and Radiological Engineering University of Illinois

More information

Defining and Labeling Circuits and Electrical Phasing in PLS-CADD

Defining and Labeling Circuits and Electrical Phasing in PLS-CADD 610 N. Whitney Way, Suite 160 Madison, WI 53705 Phone: 608.238.2171 Fax: 608.238.9241 Email:info@powline.com URL: http://www.powline.com Defining and Labeling Circuits and Electrical Phasing in PLS-CADD

More information

INDIAN INSTITUTE OF TECHNOLOGY KHARAGPUR NPTEL ONLINE CERTIFICATION COURSE. On Industrial Automation and Control

INDIAN INSTITUTE OF TECHNOLOGY KHARAGPUR NPTEL ONLINE CERTIFICATION COURSE. On Industrial Automation and Control INDIAN INSTITUTE OF TECHNOLOGY KHARAGPUR NPTEL ONLINE CERTIFICATION COURSE On Industrial Automation and Control By Prof. S. Mukhopadhyay Department of Electrical Engineering IIT Kharagpur Topic Lecture

More information

Lab experience 1: Introduction to LabView

Lab experience 1: Introduction to LabView Lab experience 1: Introduction to LabView LabView is software for the real-time acquisition, processing and visualization of measured data. A LabView program is called a Virtual Instrument (VI) because

More information

Cisco Spectrum Expert Software Overview

Cisco Spectrum Expert Software Overview CHAPTER 5 If your computer has an 802.11 interface, it should be enabled in order to detect Wi-Fi devices. If you are connected to an AP or ad-hoc network through the 802.11 interface, you will occasionally

More information

SpikePac User s Guide

SpikePac User s Guide SpikePac User s Guide Updated: 7/22/2014 SpikePac User's Guide Copyright 2008-2014 Tucker-Davis Technologies, Inc. (TDT). All rights reserved. No part of this manual may be reproduced or transmitted in

More information

Fig. 1. The Front Panel (Graphical User Interface)

Fig. 1. The Front Panel (Graphical User Interface) ME 4710 Motion and Control Data Acquisition Software for Step Excitation Introduction o These notes describe LabVIEW software that can be used for data acquisition. The overall software characteristics

More information

Preset 10 Ethernet Interface Configuration & Owner s Manual

Preset 10 Ethernet Interface Configuration & Owner s Manual Preset 10 Ethernet Interface Configuration & Owner s Manual model: PRE10E-A Doug Fleenor Design, Inc. 396 Corbett Canyon Road Arroyo Grande, CA 93420 (805) 481-9599 Voice and FAX Manual Revision 0 September

More information

invr User s Guide Rev 1.4 (Aug. 2004)

invr User s Guide Rev 1.4 (Aug. 2004) Contents Contents... 2 1. Program Installation... 4 2. Overview... 4 3. Top Level Menu... 4 3.1 Display Window... 9 3.1.1 Channel Status Indicator Area... 9 3.1.2. Quick Control Menu... 10 4. Detailed

More information

REFURBISHMENT OF SECONDARY SYSTEMS IN HIGH VOLTAGE SUBSTATIONS LESSONS LEARNED IN VENEZUELA

REFURBISHMENT OF SECONDARY SYSTEMS IN HIGH VOLTAGE SUBSTATIONS LESSONS LEARNED IN VENEZUELA 21, rue d'artois, F-75008 Paris http://www.cigre.org B3-110 Session 2004 CIGRÉ REFURBISHMENT OF SECONDARY SYSTEMS IN HIGH VOLTAGE SUBSTATIONS LESSONS LEARNED IN VENEZUELA by E. PADILLA * L. CEDEÑO E. PELAYO

More information

CI-218 / CI-303 / CI430

CI-218 / CI-303 / CI430 CI-218 / CI-303 / CI430 Network Camera User Manual English AREC Inc. All Rights Reserved 2017. l www.arec.com All information contained in this document is Proprietary Table of Contents 1. Overview 1.1

More information

Please feel free to download the Demo application software from analogarts.com to help you follow this seminar.

Please feel free to download the Demo application software from analogarts.com to help you follow this seminar. Hello, welcome to Analog Arts spectrum analyzer tutorial. Please feel free to download the Demo application software from analogarts.com to help you follow this seminar. For this presentation, we use a

More information

Session 1 Introduction to Data Acquisition and Real-Time Control

Session 1 Introduction to Data Acquisition and Real-Time Control EE-371 CONTROL SYSTEMS LABORATORY Session 1 Introduction to Data Acquisition and Real-Time Control Purpose The objectives of this session are To gain familiarity with the MultiQ3 board and WinCon software.

More information

6.111 Project Proposal IMPLEMENTATION. Lyne Petse Szu-Po Wang Wenting Zheng

6.111 Project Proposal IMPLEMENTATION. Lyne Petse Szu-Po Wang Wenting Zheng 6.111 Project Proposal Lyne Petse Szu-Po Wang Wenting Zheng Overview: Technology in the biomedical field has been advancing rapidly in the recent years, giving rise to a great deal of efficient, personalized

More information

TV Synchronism Generation with PIC Microcontroller

TV Synchronism Generation with PIC Microcontroller TV Synchronism Generation with PIC Microcontroller With the widespread conversion of the TV transmission and coding standards, from the early analog (NTSC, PAL, SECAM) systems to the modern digital formats

More information

Computer Graphics. Introduction

Computer Graphics. Introduction Computer Graphics Introduction Introduction Computer Graphics : It involves display manipulation and storage of pictures and experimental data for proper visualization using a computer. Typically graphics

More information

Data Acquisition Using LabVIEW

Data Acquisition Using LabVIEW Experiment-0 Data Acquisition Using LabVIEW Introduction The objectives of this experiment are to become acquainted with using computer-conrolled instrumentation for data acquisition. LabVIEW, a program

More information

D-Lab & D-Lab Control Plan. Measure. Analyse. User Manual

D-Lab & D-Lab Control Plan. Measure. Analyse. User Manual D-Lab & D-Lab Control Plan. Measure. Analyse User Manual Valid for D-Lab Versions 2.0 and 2.1 September 2011 Contents Contents 1 Initial Steps... 6 1.1 Scope of Supply... 6 1.1.1 Optional Upgrades... 6

More information

welcome to i-guide 09ROVI1204 User i-guide Manual R16.indd 3

welcome to i-guide 09ROVI1204 User i-guide Manual R16.indd 3 welcome to i-guide Introducing the interactive program guide from Rovi and your cable system. i-guide is intuitive, intelligent and inspiring. It unlocks a world of greater choice, convenience and control

More information

ENGINEER AND CONSULTANT IP VIDEO BRIEFING BOOK

ENGINEER AND CONSULTANT IP VIDEO BRIEFING BOOK SPRING 2008 ENGINEER AND CONSULTANT IP VIDEO BRIEFING BOOK Leading the Security Industry Since 1967 A & E SUPPORT SERVICES World Headquarters 89 Arkay Drive Hauppauge, NY 11788 Phone: 800-645-9116 Richard

More information

AMIQ-K2 Program for Transferring Various-Format I/Q Data to AMIQ. Products: AMIQ, SMIQ

AMIQ-K2 Program for Transferring Various-Format I/Q Data to AMIQ. Products: AMIQ, SMIQ Products: AMIQ, SMIQ AMIQ-K2 Program for Transferring Various-Format I/Q Data to AMIQ The software AMIQ-K2 enables you to read, convert, and transfer various-format I/Q data files to AMIQ format. AMIQ-K2

More information

High Performance Raster Scan Displays

High Performance Raster Scan Displays High Performance Raster Scan Displays Item Type text; Proceedings Authors Fowler, Jon F. Publisher International Foundation for Telemetering Journal International Telemetering Conference Proceedings Rights

More information

Generator protection relay

Generator protection relay Page 1 Issued: April 1999 Status: New Data subject to change without notice Features Off-the-shelf generator protection relay for small and medium sized power generators Three-phase time overcurrent and

More information

System Requirements SA0314 Spectrum analyzer:

System Requirements SA0314 Spectrum analyzer: System Requirements SA0314 Spectrum analyzer: System requirements Windows XP, 7, Vista or 8: 1 GHz or faster 32-bit or 64-bit processor 1 GB RAM 10 MB hard disk space \ 1. Getting Started Insert DVD into

More information

Triple RTD. On-board Digital Signal Processor. Linearization RTDs 20 Hz averaged outputs 16-bit precision comparator function.

Triple RTD. On-board Digital Signal Processor. Linearization RTDs 20 Hz averaged outputs 16-bit precision comparator function. Triple RTD SMART INPUT MODULE State-of-the-art Electromagnetic Noise Suppression Circuitry. Ensures signal integrity even in harsh EMC environments. On-board Digital Signal Processor. Linearization RTDs

More information

Linkage 3.6. User s Guide

Linkage 3.6. User s Guide Linkage 3.6 User s Guide David Rector Friday, December 01, 2017 Table of Contents Table of Contents... 2 Release Notes (Recently New and Changed Stuff)... 3 Installation... 3 Running the Linkage Program...

More information

Table of content. Table of content Introduction Concepts Hardware setup...4

Table of content. Table of content Introduction Concepts Hardware setup...4 Table of content Table of content... 1 Introduction... 2 1. Concepts...3 2. Hardware setup...4 2.1. ArtNet, Nodes and Switches...4 2.2. e:cue butlers...5 2.3. Computer...5 3. Installation...6 4. LED Mapper

More information

HCS-4100/20 Series Application Software

HCS-4100/20 Series Application Software HCS-4100/20 Series Application Software HCS-4100/20 application software is comprehensive, reliable and user-friendly. But it is also an easy care software system which helps the operator to manage the

More information

Introduction To LabVIEW and the DSP Board

Introduction To LabVIEW and the DSP Board EE-289, DIGITAL SIGNAL PROCESSING LAB November 2005 Introduction To LabVIEW and the DSP Board 1 Overview The purpose of this lab is to familiarize you with the DSP development system by looking at sampling,

More information

Getting started with

Getting started with Getting started with Electricity consumption monitoring single phase for homes and some smaller light commercial premises OVERVIEW: The OWL Intuition-e electricity monitoring system comprises of three

More information

GS122-2L. About the speakers:

GS122-2L. About the speakers: Dan Leighton DL Consulting Andrea Bell GS122-2L A growing number of utilities are adapting Autodesk Utility Design (AUD) as their primary design tool for electrical utilities. You will learn the basics

More information

PYROPTIX TM IMAGE PROCESSING SOFTWARE

PYROPTIX TM IMAGE PROCESSING SOFTWARE Innovative Technologies for Maximum Efficiency PYROPTIX TM IMAGE PROCESSING SOFTWARE V1.0 SOFTWARE GUIDE 2017 Enertechnix Inc. PyrOptix Image Processing Software v1.0 Section Index 1. Software Overview...

More information

Implementing VGA Application on FPGA using an Innovative Algorithm with the help of NIOS-II

Implementing VGA Application on FPGA using an Innovative Algorithm with the help of NIOS-II Implementing VGA Application on FPGA using an Innovative Algorithm with the help of NIOS-II Ashish B. Pasaya 1 1 E & C Engg. Department, Sardar Vallabhbhai Patel institute of technology, Vasad, Gujarat,

More information

KF200 PORTABLE MANUAL

KF200 PORTABLE MANUAL KF200 PORTABLE MANUAL THIS MANUAL CONTAINS: KF200 OPERATORS MANUAL KF200 GRAIN SOFTWARE MANUAL SPECIAL NOTE BOONE CABLE WORKS & ELECTRONICS, INC. 1773-219TH LANE - P.O. BOX 369 READ THIS ENTIRE BOOKLET

More information

Effective Test Procedures for Installing and Maintaining RF Transmitter Sites

Effective Test Procedures for Installing and Maintaining RF Transmitter Sites Product: Hand Held Spectrum Analyzer R&S FSH3 Effective Test Procedures for Installing and Maintaining RF Transmitter Sites This application note describes an effective method for generating test setups,

More information

ME EN 363 ELEMENTARY INSTRUMENTATION Lab: Basic Lab Instruments and Data Acquisition

ME EN 363 ELEMENTARY INSTRUMENTATION Lab: Basic Lab Instruments and Data Acquisition ME EN 363 ELEMENTARY INSTRUMENTATION Lab: Basic Lab Instruments and Data Acquisition INTRODUCTION Many sensors produce continuous voltage signals. In this lab, you will learn about some common methods

More information

Next Generation Software Solution for Sound Engineering

Next Generation Software Solution for Sound Engineering Next Generation Software Solution for Sound Engineering HEARING IS A FASCINATING SENSATION ArtemiS SUITE ArtemiS SUITE Binaural Recording Analysis Playback Troubleshooting Multichannel Soundscape ArtemiS

More information

CDV07. Analog video distribution amplifier(s)

CDV07. Analog video distribution amplifier(s) CDV07 Analog video distribution amplifier(s) TECHNICAL MANUAL CDV07 Analog video distribution amplifier Lange Wagenstraat 55 NL-5126 BB Gilze The Netherlands Phone: +31 161 850 450 Fax: +31 161 850 499

More information

VideoMate U3 Digital Terrestrial USB 2.0 TV Box Start Up Guide

VideoMate U3 Digital Terrestrial USB 2.0 TV Box Start Up Guide VideoMate U3 Digital Terrestrial USB 2.0 TV Box Start Up Guide Compro Technology, Inc. www.comprousa.com Copyright 2001-2005. Compro Technology, Inc. No part of this document may be copied or reproduced

More information

TV Character Generator

TV Character Generator TV Character Generator TV CHARACTER GENERATOR There are many ways to show the results of a microcontroller process in a visual manner, ranging from very simple and cheap, such as lighting an LED, to much

More information

KNX Technical Reference Manual Busch-EnergyControl

KNX Technical Reference Manual Busch-EnergyControl 0073-1-7703 Rev. 02 05.2011 KNX Technical Reference Manual Busch-EnergyControl 6762-500 Efficiency with a future Less consumption and fewer costs pay off for people and the environment. You only need the

More information

Software Quick Manual

Software Quick Manual XX113-30-00 Workstation and NVR Quick Manual Vicon Industries Inc. does not warrant that the functions contained in this equipment will meet your requirements or that the operation will be entirely error

More information

S-Series Server Setup Quiz

S-Series Server Setup Quiz 1. In the System Setup window, System Information displays additional information such as: (a) IP Address (b) Modems (c) Sound Card (d) Video Channels and Audio Channels 2. You can change the Recording

More information

Vision Call Statistics User Guide

Vision Call Statistics User Guide The Vision Call Reporting package is a web based near real time statistical tool that enables users to understand the call flow of inbound traffic both in terms of where calls have come from and also how

More information

E X P E R I M E N T 1

E X P E R I M E N T 1 E X P E R I M E N T 1 Getting to Know Data Studio Produced by the Physics Staff at Collin College Copyright Collin College Physics Department. All Rights Reserved. University Physics, Exp 1: Getting to

More information

TABLE OF CONTENTS 1. OVERVIEW INSTALLATION DA-3G CONNECTIONS SPECIFICATIONS SERIAL VIDEO INPUT...

TABLE OF CONTENTS 1. OVERVIEW INSTALLATION DA-3G CONNECTIONS SPECIFICATIONS SERIAL VIDEO INPUT... TABLE OF CONTENTS 1. OVERVIEW... 1 2. INSTALLATION... 3 2.1. 500DA-3G CONNECTIONS... 3 3. SPECIFICATIONS... 4 3.1. SERIAL VIDEO INPUT... 4 3.2. SERIAL VIDEO OUTPUT... 4 3.3. ELECTRICAL... 4 3.4. PHYSICAL...

More information

inside i-guidetm user reference manual 09ROVI1204 User i-guide Manual R16.indd 1

inside i-guidetm user reference manual 09ROVI1204 User i-guide Manual R16.indd 1 inside i-guidetm user reference manual 09ROVI1204 User i-guide Manual R16.indd 1 4/6/10 12:26:18 PM Copyright 2010 Rovi Corporation. All rights reserved. Rovi and the Rovi logo are trademarks of Rovi Corporation

More information

Toronto Hydro - Electric System

Toronto Hydro - Electric System Toronto Hydro - Electric System FIT Commissioning Requirements and Reports Comments and inquiries can be e-mailed to: FIT@torontohydro.com Customers without e-mail access can submit through regular mail

More information

NEW. Simply smart. Simply LUXOR. The LUXORliving smart home system.

NEW. Simply smart. Simply LUXOR. The LUXORliving smart home system. NEW Simply smart. Simply LUXOR. The LUXORliving smart home system. LUXORliving controls your building. Simply safe. The new LUXORliving smart home system. LUXORliving is the intuitive smart home system

More information

PCIe: EYE DIAGRAM ANALYSIS IN HYPERLYNX

PCIe: EYE DIAGRAM ANALYSIS IN HYPERLYNX PCIe: EYE DIAGRAM ANALYSIS IN HYPERLYNX w w w. m e n t o r. c o m PCIe: Eye Diagram Analysis in HyperLynx PCI Express Tutorial This PCI Express tutorial will walk you through time-domain eye diagram analysis

More information

SR-D8-M, SR-D8-S. (Ver ) SOFTWARE INSTRUCTIONS

SR-D8-M, SR-D8-S. (Ver ) SOFTWARE INSTRUCTIONS SOFTWARE INSTRUCTIONS active l ine array speak er SYStems SR-D8-M, SR-D8-S (Ver. 1.1.1) Thank you for purchasing TOA's Active Line Array Speaker Systems. Please carefully follow the instructions in this

More information

Logisim: A graphical system for logic circuit design and simulation

Logisim: A graphical system for logic circuit design and simulation Logisim: A graphical system for logic circuit design and simulation October 21, 2001 Abstract Logisim facilitates the practice of designing logic circuits in introductory courses addressing computer architecture.

More information

Teacher s AIDE Training System. EZ Teach Silver Installation

Teacher s AIDE Training System. EZ Teach Silver Installation Teacher s AIDE Training System EZ Teach Silver Installation A front row seat for every Student in your class! Page 1 of 17 TRODUCTION...3 EZ TEACH SILVER STALLATION 5 EASY STEPS...3 EZ Teach Components...3

More information

Compressed Air Management Systems SIGMA AIR MANAGER Pressure flexibility Switching losses Control losses next.

Compressed Air Management Systems SIGMA AIR MANAGER Pressure flexibility Switching losses Control losses next. Compressed Air Management Systems SIGMA AIR MANAGER Pressure flexibility Switching losses Control losses next.generation Sigma Air Manager Integrated performance for maximum energy savings An orchestra

More information

Reference Guide 2015 ZOOM CORPORATION. Copying or reprinting this manual in part or in whole without permission is prohibited.

Reference Guide 2015 ZOOM CORPORATION. Copying or reprinting this manual in part or in whole without permission is prohibited. Reference Guide 2015 ZOOM CORPORATION Copying or reprinting this manual in part or in whole without permission is prohibited. Introduction is a mixer application designed specifically for the. Using a

More information

The BAT WAVE ANALYZER project

The BAT WAVE ANALYZER project The BAT WAVE ANALYZER project Conditions of Use The Bat Wave Analyzer program is free for personal use and can be redistributed provided it is not changed in any way, and no fee is requested. The Bat Wave

More information

NOTICE: This document is for use only at UNSW. No copies can be made of this document without the permission of the authors.

NOTICE: This document is for use only at UNSW. No copies can be made of this document without the permission of the authors. Brüel & Kjær Pulse Primer University of New South Wales School of Mechanical and Manufacturing Engineering September 2005 Prepared by Michael Skeen and Geoff Lucas NOTICE: This document is for use only

More information

Your remote control holds the key to navigating through the features of i-guide. Words appearing in ALL CAPS refer to a specific button on the remote. Note that all remotes may not have all of the buttons.

More information

Altera s Max+plus II Tutorial

Altera s Max+plus II Tutorial Altera s Max+plus II Tutorial Written by Kris Schindler To accompany Digital Principles and Design (by Donald D. Givone) 8/30/02 1 About Max+plus II Altera s Max+plus II is a powerful simulation package

More information

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A)

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODULE T I A Training Document Page 1 of 66 Module This document has been written by Siemens AG for training

More information

PSC300 Operation Manual

PSC300 Operation Manual PSC300 Operation Manual Version 9.10 General information Prior to any attempt to operate this Columbia PSC 300, operator should read and understand the complete operation of the cubing system. It is very

More information

BioTechnology. An Indian Journal FULL PAPER. Trade Science Inc.

BioTechnology. An Indian Journal FULL PAPER. Trade Science Inc. [Type text] [Type text] [Type text] ISSN : 0974-7435 Volume 10 Issue 19 BioTechnology 2014 An Indian Journal FULL PAPER BTAIJ, 10(19), 2014 [11171-11176] Study on background monitoring system of intelligent

More information

XNET-NVR User s Guide

XNET-NVR User s Guide XNET-NVR User s Guide Ver. 1.0 (070918) 1 of 39 Table of Contents 1. Program Installation... 4 2. Overview... 4 3. Top Level Menu... 5 3.1. Display Window... 9 3.1.1. Channel Status Indicator Area... 9

More information

Witold MICKIEWICZ, Jakub JELEŃ

Witold MICKIEWICZ, Jakub JELEŃ ARCHIVES OF ACOUSTICS 33, 1, 11 17 (2008) SURROUND MIXING IN PRO TOOLS LE Witold MICKIEWICZ, Jakub JELEŃ Technical University of Szczecin Al. Piastów 17, 70-310 Szczecin, Poland e-mail: witold.mickiewicz@ps.pl

More information

iutilities Dynamic multi-process visualization and control

iutilities Dynamic multi-process visualization and control iutilities Dynamic multi-process visualization and control i N T E L L I G E N T i N N O V A T I V E i N T E G R A T E D i N T E R A C T I V E All-in-one digital solution for managed process monitoring

More information

DIGITAL INSTRUMENTS S.R.L. SPM-ETH (Synchro Phasor Meter over ETH)

DIGITAL INSTRUMENTS S.R.L. SPM-ETH (Synchro Phasor Meter over ETH) DIGITAL INSTRUMENTS S.R.L. SPM-ETH (Synchro Phasor Meter over ETH) SPM-ETH (Synchro Phasor Meter over ETH) Digital Instruments 1 ver the years, an awareness of the criticality of the Power Grid and Orelated

More information

Introduction to GRIP. The GRIP user interface consists of 4 parts:

Introduction to GRIP. The GRIP user interface consists of 4 parts: Introduction to GRIP GRIP is a tool for developing computer vision algorithms interactively rather than through trial and error coding. After developing your algorithm you may run GRIP in headless mode

More information

Analyze Frequency Response (Bode Plots) with R&S Oscilloscopes Application Note

Analyze Frequency Response (Bode Plots) with R&S Oscilloscopes Application Note Analyze Frequency Response (Bode Plots) with R&S Oscilloscopes Application Note Products: R&S RTO2002 R&S RTO2004 R&S RTO2012 R&S RTO2014 R&S RTO2022 R&S RTO2024 R&S RTO2044 R&S RTO2064 This application

More information

Multiband Noise Reduction Component for PurePath Studio Portable Audio Devices

Multiband Noise Reduction Component for PurePath Studio Portable Audio Devices Multiband Noise Reduction Component for PurePath Studio Portable Audio Devices Audio Converters ABSTRACT This application note describes the features, operating procedures and control capabilities of a

More information

YXLON Cougar EVO PLUS

YXLON Cougar EVO PLUS YXLON Cougar EVO PLUS The best small footprint X-ray inspection system for LABORATORY applications Technology with Passion Choose a custom-built EVO solution for premium inspection Why compromise? As technology

More information

A generic real-time video processing unit for low vision

A generic real-time video processing unit for low vision International Congress Series 1282 (2005) 1075 1079 www.ics-elsevier.com A generic real-time video processing unit for low vision Fernando Vargas-Martín a, *, M. Dolores Peláez-Coca a, Eduardo Ros b, Javier

More information

INSTALATION AND OPERATION MANUAL ABYSSAL OS Overlay Module Version 1.0.1

INSTALATION AND OPERATION MANUAL ABYSSAL OS Overlay Module Version 1.0.1 INSTALATION AND OPERATION MANUAL ABYSSAL OS Overlay Module Version 1.0.1 Thank you for purchasing the Abyssal OS Overlay Module for your ROV. This instruction manual contains all the information you ll

More information

Statement SmartLCT User s Manual Welcome to use the product from Xi an NovaStar Tech Co., Ltd. (hereinafter referred to as NovaStar ). It is our great

Statement SmartLCT User s Manual Welcome to use the product from Xi an NovaStar Tech Co., Ltd. (hereinafter referred to as NovaStar ). It is our great LED Display Configuration Software SmartLCT User s Manual Software Version: V3.0 Rev3.0.0 NS110100239 Statement SmartLCT User s Manual Welcome to use the product from Xi an NovaStar Tech Co., Ltd. (hereinafter

More information

Crestron TPMC-4SM Fusion RV Interface Operations Guide

Crestron TPMC-4SM Fusion RV Interface Operations Guide Crestron TPMC-4SM Fusion RV Interface Operations Guide The specific patents that cover Crestron products are listed at patents.crestron.com. Crestron, the Crestron logo and Fusion RV are either trademarks

More information

ZYLIA Studio PRO reference manual v1.0.0

ZYLIA Studio PRO reference manual v1.0.0 1 ZYLIA Studio PRO reference manual v1.0.0 2 Copyright 2017 Zylia sp. z o.o. All rights reserved. Made in Poland. This manual, as well as the software described in it, is furnished under license and may

More information

DAC20. 4 Channel Analog Audio Output Synapse Add-On Card

DAC20. 4 Channel Analog Audio Output Synapse Add-On Card DAC20 4 Channel Analog Audio Output Synapse Add-On Card TECHNICAL MANUAL DAC20 Analog Audio Delay Line Lange Wagenstraat 55 NL-5126 BB Gilze The Netherlands Phone: +31 161 850 450 Fax: +31 161 850 499

More information

PRODUCT BROCHURE. Gemini Matrix Intercom System. Mentor RG + MasterMind Sync and Test Pulse Generator

PRODUCT BROCHURE. Gemini Matrix Intercom System. Mentor RG + MasterMind Sync and Test Pulse Generator PRODUCT BROCHURE Gemini Matrix Intercom System Mentor RG + MasterMind Sync and Test Pulse Generator GEMINI DIGITAL MATRIX INTERCOM SYSTEM In high profile broadcast environments operating around the clock,

More information

Basic LabVIEW Programming Amit J Nimunkar, Sara Karle, Michele Lorenz, Emily Maslonkowski

Basic LabVIEW Programming Amit J Nimunkar, Sara Karle, Michele Lorenz, Emily Maslonkowski Introduction This lab familiarizes you with the software package LabVIEW from National Instruments for data acquisition and virtual instrumentation. The lab also introduces you to resistors, capacitors,

More information

Reference Guide 2014 ZOOM CORPORATION. Copying or reprinting this manual in part or in whole without permission is prohibited.

Reference Guide 2014 ZOOM CORPORATION. Copying or reprinting this manual in part or in whole without permission is prohibited. Reference Guide 2014 ZOOM CORPORATION Copying or reprinting this manual in part or in whole without permission is prohibited. Introduction is a mixer application designed specifically for the. Using a

More information

DMX 512 Language Date: Venerdì, febbraio 12:15:08 CET Topic: Educational Lighting Site

DMX 512 Language Date: Venerdì, febbraio 12:15:08 CET Topic: Educational Lighting Site DMX 512 Language Date: Venerdì, febbraio 15 @ 12:15:08 CET Topic: Educational Lighting Site DMX512 Cable Connectors Principles of functioning Distaces Terminations Splitter & Buffer DMX 1990 Until a few

More information

Configuring the Stack ST8961 VS Module when used in conjunction with a Stack ST81xx series display.

Configuring the Stack ST8961 VS Module when used in conjunction with a Stack ST81xx series display. Configuring the Stack ST8961 VS Module when used in conjunction with a Stack ST81xx series display. Your Stack ST8961 VS module allows you to synchronize, overlay, and record data available on your Stack

More information

OPTIMUM Power Technology: Low Cost Combustion Analysis for University Engine Design Programs Using ICEview and NI Compact DAQ Chassis

OPTIMUM Power Technology: Low Cost Combustion Analysis for University Engine Design Programs Using ICEview and NI Compact DAQ Chassis OPTIMUM Power Technology: Low Cost Combustion Analysis for University Engine Design Programs Using ICEview and NI Compact DAQ Chassis World Headquarters (USA): European Sales Office: Japanese Office: 3117

More information

Intelligent Monitoring Software IMZ-RS300. Series IMZ-RS301 IMZ-RS304 IMZ-RS309 IMZ-RS316 IMZ-RS332 IMZ-RS300C

Intelligent Monitoring Software IMZ-RS300. Series IMZ-RS301 IMZ-RS304 IMZ-RS309 IMZ-RS316 IMZ-RS332 IMZ-RS300C Intelligent Monitoring Software IMZ-RS300 Series IMZ-RS301 IMZ-RS304 IMZ-RS309 IMZ-RS316 IMZ-RS332 IMZ-RS300C Flexible IP Video Monitoring With the Added Functionality of Intelligent Motion Detection With

More information

Design of Fault Coverage Test Pattern Generator Using LFSR

Design of Fault Coverage Test Pattern Generator Using LFSR Design of Fault Coverage Test Pattern Generator Using LFSR B.Saritha M.Tech Student, Department of ECE, Dhruva Institue of Engineering & Technology. Abstract: A new fault coverage test pattern generator

More information

Click Here To Start Demo

Click Here To Start Demo Click Here To Start Demo AirLogix Demo Title Screen AirLogix Interactive Demonstrator Version 3.0 Copyright 2005 by Case Engineering inc This is intended as a working active demonstration only. Every attempt

More information

2D/3D Multi-Projector Stacking Processor. User Manual AF5D-21

2D/3D Multi-Projector Stacking Processor. User Manual AF5D-21 2D/3D Multi-Projector Stacking Processor User Manual AF5D-21 Thank you for choosing AF5D-21 passive 3D processor. AF5D-21 is an advanced dual channel passive 3D processor with 10 bits high end scaler and

More information

SIWAREX FTA Weighing Module for High Accuracy Requirements Calibrating SIWAREX FTA with SIWATOOL FTA

SIWAREX FTA Weighing Module for High Accuracy Requirements Calibrating SIWAREX FTA with SIWATOOL FTA SIWAREX FTA Weighing Module for High Accuracy Requirements Calibrating SIWAREX FTA with SIWATOOL FTA Quick Guide For modules with order number 7MH4900-2AA01 Contents 1 2 3 4 5 6 Hardware-Requirements..

More information

Amplifiers STARLINE 2000 Broadband Telecommunications Distribution Amplifier [BT*/*]

Amplifiers STARLINE 2000 Broadband Telecommunications Distribution Amplifier [BT*/*] mplifiers STRLINE 2000 Broadband Telecommunications Distribution mplifier [BT*/*] FETURES 750 MHz and 870 MHz power doubling technology in Gas or silicon 60/0V powering Meets IEEE C62.41 11 and BellCore

More information

passport guide user manual

passport guide user manual passport guide user manual Copyright 2011 Rovi Corporation. All rights reserved. Rovi and the Rovi logo are trademarks of Rovi Corporation. Passport is a registered trademark of Rovi Corporation and/or

More information

Explore the Art of Detection

Explore the Art of Detection Y.Cougar Microfocus and nanofocus X-ray inspection systems for the electronics industries Explore the Art of Detection Technology with Passion Our specialty: The Art of Detection. Developing outstanding

More information

Pre-processing of revolution speed data in ArtemiS SUITE 1

Pre-processing of revolution speed data in ArtemiS SUITE 1 03/18 in ArtemiS SUITE 1 Introduction 1 TTL logic 2 Sources of error in pulse data acquisition 3 Processing of trigger signals 5 Revolution speed acquisition with complex pulse patterns 7 Introduction

More information

PulseCounter Neutron & Gamma Spectrometry Software Manual

PulseCounter Neutron & Gamma Spectrometry Software Manual PulseCounter Neutron & Gamma Spectrometry Software Manual MAXIMUS ENERGY CORPORATION Written by Dr. Max I. Fomitchev-Zamilov Web: maximus.energy TABLE OF CONTENTS 0. GENERAL INFORMATION 1. DEFAULT SCREEN

More information

FS3. Quick Start Guide. Overview. FS3 Control

FS3. Quick Start Guide. Overview. FS3 Control FS3 Quick Start Guide Overview The new FS3 combines AJA's industry-proven frame synchronization with high-quality 4K up-conversion technology to seamlessly integrate SD and HD signals into 4K workflows.

More information