1 Installation of a DAQ System in Hall C Cuore Collaboration Meeting Como, February 21 st - 23 rd 2007 S. Di Domizio A. Giachero M. Pallavicini S. Di Domizio
2 Summary slide CUORE-like DAQ system installed in HallC R&D setup 48 DAQ channels available System driven by Apollo, the CUORE DAQ software Few days data taking performed during the Clamps Run Hardware setup validation Apollo software testing and debugging
3 Hardware Setup 1 Crate 3 X 16 Ch ADC Boards NI PXI-1033 NI PXI-6284 A Patch Panel split the signal after bessel filters and send it to both the DAQ systems Detector and FE Bessel Filters Box Patch Panel Acquisition driven by a dedicated pc optically connected to the crate APOLLO DAQ VXI DAQ An improved version of the patch panel will be ready soon 4 unipolar output for oscilloscope connection Some interface to NI Boards digital I/O channels Active components are required in order to gain these features
4 Apollo DAQ Software Data taking Continuous data stream can be saved into single channel files: Useful for debugging and inspection of non standard detector performance Produced file size is ~ 160 MB/ch/day The whole DAQ chain can be reproduced offline starting from continuous data stream files Data base Basic interface with data base has been implemented, even if the currently installed db is slightly different from the one that will be used in CUORE At moment only a small bunch of setup parameters are read from the db and also few parameters are written back Trigger engine For each channel up to 4 trigger algorithm can process acquired data in parallel Trigger engine only flags the data (1 independent flag for each running trigger) The Event Builder decides how to treat the flags and builds the Root Event accordingly
5 The User Interface Basic Graphical User interface Set Run number, select Profile from DB, start and stop measurement... Virtual oscilloscope for online measurement monitor
6 Performed measurements Few days data taking performed in January and February during Clamps run: VXI and Apollo DAQ systems were run in parallel and separately Apollo data continuously saved into files for offline analysis and re-processing A first attempt of trigger has been realized in order to have a complete DAQ chain triggered events also saved in root file format In order to compare the 2 systems and study mutual influence, triggered data is converted in binary format used for standard CUORICINO analysis Analysis in progress: some preliminary results will be shown in the next slides
7 Trigger performance after binary conversion pulse max location distribution is not so bad if compared with VXI data The main purpose of the trigger algorithm was to obtain a CUORCINO-like data format for comparison with the VXI DAQ data
8 Spectrum Comparison Spectrum obtained from 3 day bkg measurement when systems were running in parallel
9 Next Steps Perform a complete analysis on the acquired data Compare VXI voltage spectrum in parallel and stand-alone measurement and repeat this exercise for all 8 acquired channels Compare power spectra for noise and signals Porting to the new DB structure Currently used db revealed potential internal incoherence Apollo GUI and monitoring tools GUI functionalities improvement Virtual scope debugging and improvement Voltage spectrum Counting rate Load Curves Working on low level communication with FE Automatic Diana-based Load curves construction and working point finder
MIE 402: WORKSHOP ON DATA ACQUISITION AND SIGNAL PROCESSING Spring 2003
MIE 402: WORKSHOP ON DATA ACQUISITION AND SIGNAL PROCESSING Spring 2003 OBJECTIVE To become familiar with state-of-the-art digital data acquisition hardware and software. To explore common data acquisition
More informationPulseCounter Neutron & Gamma Spectrometry Software Manual
PulseCounter Neutron & Gamma Spectrometry Software Manual MAXIMUS ENERGY CORPORATION Written by Dr. Max I. Fomitchev-Zamilov Web: maximus.energy TABLE OF CONTENTS 0. GENERAL INFORMATION 1. DEFAULT SCREEN
More informationPITZ Introduction to the Video System
PITZ Introduction to the Video System Stefan Weiße DESY Zeuthen June 10, 2003 Agenda 1. Introduction to PITZ 2. Why a video system? 3. Schematic structure 4. Client/Server architecture 5. Hardware 6. Software
More informationLab 1 Introduction to the Software Development Environment and Signal Sampling
ECEn 487 Digital Signal Processing Laboratory Lab 1 Introduction to the Software Development Environment and Signal Sampling Due Dates This is a three week lab. All TA check off must be completed before
More informationCAEN Tools for Discovery
Viareggio March 28, 2011 Introduction: what is the SiPM? The Silicon PhotoMultiplier (SiPM) consists of a high density (up to ~10 3 /mm 2 ) matrix of diodes connected in parallel on a common Si substrate.
More informationME EN 363 ELEMENTARY INSTRUMENTATION Lab: Basic Lab Instruments and Data Acquisition
ME EN 363 ELEMENTARY INSTRUMENTATION Lab: Basic Lab Instruments and Data Acquisition INTRODUCTION Many sensors produce continuous voltage signals. In this lab, you will learn about some common methods
More informationGREAT 32 channel peak sensing ADC module: User Manual
GREAT 32 channel peak sensing ADC module: User Manual Specification: 32 independent timestamped peak sensing, ADC channels. Input range 0 to +8V. Sliding scale correction. Peaking time greater than 1uS.
More informationTechniques for Extending Real-Time Oscilloscope Bandwidth
Techniques for Extending Real-Time Oscilloscope Bandwidth Over the past decade, data communication rates have increased by a factor well over 10X. Data rates that were once 1Gb/sec and below are now routinely
More information8 DIGITAL SIGNAL PROCESSOR IN OPTICAL TOMOGRAPHY SYSTEM
Recent Development in Instrumentation System 99 8 DIGITAL SIGNAL PROCESSOR IN OPTICAL TOMOGRAPHY SYSTEM Siti Zarina Mohd Muji Ruzairi Abdul Rahim Chiam Kok Thiam 8.1 INTRODUCTION Optical tomography involves
More informationPC-based Personal DSP Training Station
Session 1220 PC-based Personal DSP Training Station Armando B. Barreto 1, Kang K. Yen 1 and Cesar D. Aguilar Electrical and Computer Engineering Department Florida International University This paper describes
More informationPRELIMINARY INFORMATION. Professional Signal Generation and Monitoring Options for RIFEforLIFE Research Equipment
Integrated Component Options Professional Signal Generation and Monitoring Options for RIFEforLIFE Research Equipment PRELIMINARY INFORMATION SquareGENpro is the latest and most versatile of the frequency
More informationSUBSYSTEMS FOR DATA ACQUISITION #39. Analog-to-Digital Converter (ADC) Function Card
SUBSYSTEMS FOR DATA ACQUISITION #39 Analog-to-Digital Converter (ADC) Function Card Project Scope Design an ADC function card for an IEEE 488 interface box built by Dr. Robert Kolbas. ADC card will add
More informationUsing SignalTap II in the Quartus II Software
White Paper Using SignalTap II in the Quartus II Software Introduction The SignalTap II embedded logic analyzer, available exclusively in the Altera Quartus II software version 2.1, helps reduce verification
More informationCMS Conference Report
Available on CMS information server CMS CR 1997/017 CMS Conference Report 22 October 1997 Updated in 30 March 1998 Trigger synchronisation circuits in CMS J. Varela * 1, L. Berger 2, R. Nóbrega 3, A. Pierce
More informationLow-Cost Personal DSP Training Station based on the TI C3x DSK
Low-Cost Personal DSP Training Station based on the TI C3x DSK Armando B. Barreto 1 and Cesar D. Aguilar Electrical and Computer Engineering Florida International University, CEAS-3942 Miami, FL, 33199
More informationLog-detector. Sweeper setup using oscilloscope as XY display
2002/9/4 Version 1.2 XYdisp user manual. 1. Introduction. The XYdisp program is a tool for using an old DOS PC or laptop as XY display to show response curves measured by a sweeper log-detector combination.
More informationVIRTUAL INSTRUMENTATION
VIRTUAL INSTRUMENTATION Virtual instrument an equimplent that allows accomplishment of measurements using the computer. It looks like a real instrument, but its operation and functionality is essentially
More informationDPD80 Visible Datasheet
Data Sheet v1.3 Datasheet Resolved Inc. www.resolvedinstruments.com info@resolvedinstruments.com 217 Resolved Inc. All rights reserved. General Description The DPD8 is a low noise digital photodetector
More informationAR SWORD Digital Receiver EXciter (DREX)
Typical Applications Applied Radar, Inc. Radar Pulse-Doppler processing General purpose waveform generation and collection Multi-channel digital beamforming Military applications SIGINT/ELINT MIMO and
More information3. Configuration and Testing
3. Configuration and Testing C51003-1.4 IEEE Std. 1149.1 (JTAG) Boundary Scan Support All Cyclone devices provide JTAG BST circuitry that complies with the IEEE Std. 1149.1a-1990 specification. JTAG boundary-scan
More informationDPD80 Infrared Datasheet
Data Sheet v1.4 DPD8 Infrared DPD8 Infrared Datasheet Resolved Inc. www.resolvedinstruments.com info@resolvedinstruments.com 217 Resolved Inc. All rights reserved. DPD8 Infrared General Description The
More informationRecording of Coincidence Signals in a Software Medium
Science Journal of Circuits, Systems and Signal Processing 2018; 7(1): 28-33 http://www.sciencepublishinggroup.com/j/cssp doi: 10.11648/j.cssp.20180701.14 ISSN: 2326-9065 (Print); ISSN: 2326-9073 (Online)
More informationIntroduction to GRIP. The GRIP user interface consists of 4 parts:
Introduction to GRIP GRIP is a tool for developing computer vision algorithms interactively rather than through trial and error coding. After developing your algorithm you may run GRIP in headless mode
More informationIntegration of Virtual Instrumentation into a Compressed Electricity and Electronic Curriculum
Integration of Virtual Instrumentation into a Compressed Electricity and Electronic Curriculum Arif Sirinterlikci Ohio Northern University Background Ohio Northern University Technological Studies Department
More informationPEP-II longitudinal feedback and the low groupdelay. Dmitry Teytelman
PEP-II longitudinal feedback and the low groupdelay woofer Dmitry Teytelman 1 Outline I. PEP-II longitudinal feedback and the woofer channel II. Low group-delay woofer topology III. Why do we need a separate
More informationGALILEO Timing Receiver
GALILEO Timing Receiver The Space Technology GALILEO Timing Receiver is a triple carrier single channel high tracking performances Navigation receiver, specialized for Time and Frequency transfer application.
More informationGetting Started with the LabVIEW Sound and Vibration Toolkit
1 Getting Started with the LabVIEW Sound and Vibration Toolkit This tutorial is designed to introduce you to some of the sound and vibration analysis capabilities in the industry-leading software tool
More informationMTL Software. Overview
MTL Software Overview MTL Windows Control software requires a 2350 controller and together - offer a highly integrated solution to the needs of mechanical tensile, compression and fatigue testing. MTL
More informationCoincidence Detection using the Broadcom AFBR-S4N44P163 4 x 4 SiPM Array and the Vertilon SIB916 Sensor Interface Board Application Note
Overview The Broadcom AFBR-S4N44P163 4 x 4 element silicon photomultiplier array and Vertilon SIB916 sensor interface board are an ideal combination for use in coincidence detection applications such as
More informationC8000. switch over & ducking
features Automatic or manual Switch Over or Fail Over in case of input level loss. Ducking of a main stereo or surround sound signal by a line level microphone or by a pre recorded announcement / ad input.
More informationBuilding Video and Audio Test Systems. NI Technical Symposium 2008
Building Video and Audio Test Systems NI Technical Symposium 2008 2 Multimedia Device Testing Challenges Integrating a wide range of measurement types Reducing test time while the number of features increases
More informationA Versatile Multichannel Digital Signal Processing Module for Microcalorimeter Arrays
A Versatile Multichannel Digital Signal Processing Module for Microcalorimeter Arrays H. Tan, J. W. Collins, M. Walby, W. Hennig, W. K. Warburton, P. Grudberg XIA LLC, 3157 Genstar Rd, Hayward, CA 94544,
More informationEAN-Performance and Latency
EAN-Performance and Latency PN: EAN-Performance-and-Latency 6/4/2018 SightLine Applications, Inc. Contact: Web: sightlineapplications.com Sales: sales@sightlineapplications.com Support: support@sightlineapplications.com
More informationQuick Reference Manual
Quick Reference Manual V1.0 1 Contents 1.0 PRODUCT INTRODUCTION...3 2.0 SYSTEM REQUIREMENTS...5 3.0 INSTALLING PDF-D FLEXRAY PROTOCOL ANALYSIS SOFTWARE...5 4.0 CONNECTING TO AN OSCILLOSCOPE...6 5.0 CONFIGURE
More informationProposed reference equalizer change in Clause 124 (TDECQ/SECQ. methodologies).
Proposed reference equalizer change in Clause 124 (TDECQ/SECQ methodologies). 25th April 2017 P802.3bs SMF ad hoc Atul Gupta, Macom Marco Mazzini, Cisco Introduction In mazzini_01a_0317_smf, some concerns
More informationAI-1616L-LPE. Features. High-precision Analog input board (Low Profile size) for PCI Express AI-1616L-LPE 1. Ver.1.02 Ver.1.01
High-precision Analog input board (Low Profile size) for PCI Express AI-1616L-LPE This product is a multi-function, PCI Express bus-compliant interface board that incorporates high-precision 16-bit analog
More informationLogic Analysis Basics
Logic Analysis Basics September 27, 2006 presented by: Alex Dickson Copyright 2003 Agilent Technologies, Inc. Introduction If you have ever asked yourself these questions: What is a logic analyzer? What
More informationLogic Analysis Basics
Logic Analysis Basics September 27, 2006 presented by: Alex Dickson Copyright 2003 Agilent Technologies, Inc. Introduction If you have ever asked yourself these questions: What is a logic analyzer? What
More informationAI-1204Z-PCI. Features. 10MSPS, 12-bit Analog Input Board for PCI AI-1204Z-PCI 1. Ver.1.04
10MSPS, 12-bit Analog Board for PCI AI-1204Z-PCI * Specifications, color and design of the products are subject to change without notice. This product is a PCI bus-compliant interface board that expands
More informationMajor Differences Between the DT9847 Series Modules
DT9847 Series Dynamic Signal Analyzer for USB With Low THD and Wide Dynamic Range The DT9847 Series are high-accuracy, dynamic signal acquisition modules designed for sound and vibration applications.
More informationSample. Data Acquisition and Signal Conditioning. Course Manual. Course Software Version 2011 February 2012 Edition Part Number P-01
Data Acquisition and Signal Conditioning Course Manual Course Software Version 2011 February 2012 Edition Part Number 320733P-01 Data Acquisition and Signal Conditioning Copyright 1995 2012 National Instruments
More informationAI-1664LAX-USB. Features. 100KSPS 16-bit Analog Input Unit for USB AI-1664LAX-USB 1. Ver.1.01
100KSPS 16-bit Analog Unit for USB AI-1664LAX-USB * Specifications, color and design of the products are subject to change without notice. This product is a USB2.0-compliant analog input unit that extends
More informationDetecting and Analyzing System for the Vibration Comfort of Car Seats Based on LabVIEW
Detecting and Analyzing System for the Vibration Comfort of Car Seats Based on LabVIEW Ying Qiu Key Laboratory of Conveyance and Equipment, Ministry of Education School of Mechanical and Electronical Engineering,
More informationSignalTap Analysis in the Quartus II Software Version 2.0
SignalTap Analysis in the Quartus II Software Version 2.0 September 2002, ver. 2.1 Application Note 175 Introduction As design complexity for programmable logic devices (PLDs) increases, traditional methods
More informationAn Introduction to the Spectral Dynamics Rotating Machinery Analysis (RMA) package For PUMA and COUGAR
An Introduction to the Spectral Dynamics Rotating Machinery Analysis (RMA) package For PUMA and COUGAR Introduction: The RMA package is a PC-based system which operates with PUMA and COUGAR hardware to
More informationni.com Digital Signal Processing for Every Application
Digital Signal Processing for Every Application Digital Signal Processing is Everywhere High-Volume Image Processing Production Test Structural Sound Health and Vibration Monitoring RF WiMAX, and Microwave
More informationDT9857E. Key Features: Dynamic Signal Analyzer for Sound and Vibration Analysis Expandable to 64 Channels
DT9857E Dynamic Signal Analyzer for Sound and Vibration Analysis Expandable to 64 Channels The DT9857E is a high accuracy dynamic signal acquisition module for noise, vibration, and acoustic measurements
More informationDAC Express Release 3.4 (VT9801B)
DAC Express Release 3.4 (VT9801B) DAC Express 3.4 Highlights n Display Wizard for fast test setups n 48-channel high performance remote strain measurement unit (EX1629) n Combine multi-channel analog,
More informationELMB Full Branch Test
Fernando Varela 1 ELMB Full Branch Test Outline Architecture ELMB Full Branch Set-Up Powering I/O functionality Bus Behavior SW Architecture Test Procedure SCADA Panels Run Control Offline Analysis Findings
More informationTHE DIAGNOSTICS BACK END SYSTEM BASED ON THE IN HOUSE DEVELOPED A DA AND A D O BOARDS
THE DIAGNOSTICS BACK END SYSTEM BASED ON THE IN HOUSE DEVELOPED A DA AND A D O BOARDS A. O. Borga #, R. De Monte, M. Ferianis, L. Pavlovic, M. Predonzani, ELETTRA, Trieste, Italy Abstract Several diagnostic
More informationPAM4 signals for 400 Gbps: acquisition for measurement and signal processing
TITLE PAM4 signals for 400 Gbps: acquisition for measurement and signal processing Image V1.00 1 Introduction, content High speed serial data links are in the process in increasing line speeds from 25
More informationSwitching Solutions for Multi-Channel High Speed Serial Port Testing
Switching Solutions for Multi-Channel High Speed Serial Port Testing Application Note by Robert Waldeck VP Business Development, ASCOR Switching The instruments used in High Speed Serial Port testing are
More informationHEAD. HEAD VISOR (Code 7500ff) Overview. Features. System for online localization of sound sources in real time
HEAD Ebertstraße 30a 52134 Herzogenrath Tel.: +49 2407 577-0 Fax: +49 2407 577-99 email: info@head-acoustics.de Web: www.head-acoustics.de Data Datenblatt Sheet HEAD VISOR (Code 7500ff) System for online
More informationFPGA Development for Radar, Radio-Astronomy and Communications
John-Philip Taylor Room 7.03, Department of Electrical Engineering, Menzies Building, University of Cape Town Cape Town, South Africa 7701 Tel: +27 82 354 6741 email: tyljoh010@myuct.ac.za Internet: http://www.uct.ac.za
More informationDevelopment of an oscilloscope based TDP metric
Development of an oscilloscope based TDP metric IEEE 2015 Greg LeCheminant Supporters Jonathan King Finisar Ali Ghiasi Ghiasi Quantum 2015 Page 2 Understanding the basic instrumentation issues Equivalent-time
More informationNew GRABLINK Frame Grabbers
New GRABLINK Frame Grabbers Full-Featured Base, High-quality Medium and video Full capture Camera boards Link Frame Grabbers GRABLINK Full Preliminary GRABLINK DualBase Preliminary GRABLINK Base GRABLINK
More informationECAL LED system update. A. Celentano
ECAL LED system update A. Celentano 1 ECAL LMS overview (x 4) Design: individual bi-color LEDs mounted in front of each PbWO4 crystal. Main controllers (2 x) Driver Boards (8 x) Connection boards (4 x)
More informationDevelopment of an oscilloscope based TDP metric
Development of an oscilloscope based TDP metric IEEE 2015 Greg LeCheminant Jim Stimple Marlin Viss Supporters Jonathan King Finisar Ali Ghiasi Ghiasi Quantum Pavel Zivny Tektronix 2015 Page 2 Understanding
More informationLow Cost, High Speed Spectrum Analyzers For RF Manufacturing APPLICATION NOTE
Low Cost, High Speed Spectrum Analyzers For RF Manufacturing APPLICATION NOTE Application Note Table of Contents Spectrum Analyzers in Manufacturing...3 Low Cost USB Spectrum Analyzers for Manufacturing...3
More informationFront End Electronics
CLAS12 Ring Imaging Cherenkov (RICH) Detector Mid-term Review Front End Electronics INFN - Ferrara Matteo Turisini 2015 October 13 th Overview Readout requirements Hardware design Electronics boards Integration
More informationAD16-64(LPCI)LA. Non-isolated high precision analog input board for Low Profile PCI AD16-64(LPCI)LA 1. Ver.1.01
Non-isolated high precision analog board for Low Profile PCI AD16-64(LPCI)LA * Specifications, color and design of the products are subject to change without notice. This product is a PCI bus compatible
More informationSound and Vibration Data Acquisition
NI 9233, NI 9234 NEW! 24-bit resolution 102 db dynamic range 4 simultaneous analog inputs ±5 V input range Antialiasing filters TEDS read/write Recommended Software LabVIEW Sound and Vibration Toolkit
More informationSolving Problems for Problem Solvers ELECTROPHYSIOLOGY SUITEUITE
Solving Problems for Problem Solvers LABPACAC ELECTROPHYSIOLOGY SUITEUITE Scientific Solutions LabPac ElectroPhysiology Suite Overview of the LabPac EP Suite Scientific Solutions offers the LabPac ElectroPhysiology
More informationExperiment 13 Sampling and reconstruction
Experiment 13 Sampling and reconstruction Preliminary discussion So far, the experiments in this manual have concentrated on communications systems that transmit analog signals. However, digital transmission
More informationNI-DAQmx Device Considerations
NI-DAQmx Device Considerations January 2008, 370738M-01 This help file contains information specific to analog output (AO) Series devices, C Series, B Series, E Series devices, digital I/O (DIO) devices,
More informationImproving EPICS IOC Application (EPICS user experience)
Improving EPICS IOC Application (EPICS user experience) Shantha Condamoor Instrumentation and Controls Division 1 to overcome some Software Design limitations A specific use case will be taken as an example
More informationFront End Electronics
CLAS12 Ring Imaging Cherenkov (RICH) Detector Mid-term Review Front End Electronics INFN - Ferrara Matteo Turisini 2015 October 13 th Overview Readout requirements Hardware design Electronics boards Integration
More informationA 400MHz Direct Digital Synthesizer with the AD9912
A MHz Direct Digital Synthesizer with the AD991 Daniel Da Costa danieljdacosta@gmail.com Brendan Mulholland firemulholland@gmail.com Project Sponser: Dr. Kirk W. Madison Project 11 Engineering Physics
More informationDT9837 Series. High Performance, USB Powered Modules for Sound & Vibration Analysis. Key Features:
DT9837 Series High Performance, Powered Modules for Sound & Vibration Analysis The DT9837 Series high accuracy dynamic signal acquisition modules are ideal for portable noise, vibration, and acoustic measurements.
More informationLAX_x Logic Analyzer
Legacy documentation LAX_x Logic Analyzer Summary This core reference describes how to place and use a Logic Analyzer instrument in an FPGA design. Core Reference CR0103 (v2.0) March 17, 2008 The LAX_x
More informationLEP400 Etch Depth Monitor Real-time, in-situ plasma etch depth monitoring and end point control plus co-linear wafer vision system
LEP400 Etch Depth Monitor Real-time, in-situ plasma etch depth monitoring and end point control plus co-linear wafer vision system Base Configuration Etch Depth Monitoring LEP400 Recessed Window Plasma
More informationECE 5765 Modern Communication Fall 2005, UMD Experiment 10: PRBS Messages, Eye Patterns & Noise Simulation using PRBS
ECE 5765 Modern Communication Fall 2005, UMD Experiment 10: PRBS Messages, Eye Patterns & Noise Simulation using PRBS modules basic: SEQUENCE GENERATOR, TUNEABLE LPF, ADDER, BUFFER AMPLIFIER extra basic:
More information1. Abstract. Mixed Signal Oscilloscope Ideal For Debugging Embedded Systems DLM2000 Series
Yokogawa Electric Corporation High Frequency Measurement Development Dept. C&M Business HQ. Motoaki Sugimoto 1. Abstract From digital home electronics to automobiles, a boom has recently occurred in various
More informationNanoGiant Oscilloscope/Function-Generator Program. Getting Started
Getting Started Page 1 of 17 NanoGiant Oscilloscope/Function-Generator Program Getting Started This NanoGiant Oscilloscope program gives you a small impression of the capabilities of the NanoGiant multi-purpose
More informationTrigger synchronization and phase coherent in high speed multi-channels data acquisition system
White Paper Trigger synchronization and phase coherent in high speed multi-channels data acquisition system Synopsis Trigger synchronization and phase coherent acquisition over multiple Data Acquisition
More informationTrigger Cost & Schedule
Trigger Cost & Schedule Wesley Smith, U. Wisconsin CMS Trigger Project Manager DOE/NSF Review May 9, 2001 1 Baseline L4 Trigger Costs From April '00 Review -- 5.69 M 3.96 M 1.73 M 2 Calorimeter Trig. Costs
More informationMulti-Parameter Monitoring Data Acquisition System for SpO 2 Signals
Multi-Parameter Monitoring Data Acquisition System for SpO 2 Signals Natasha Naik 1, Anupama B 2, Sandeep Patil 3, Balu Vasista 4 M.Tech Student, Department of Electronics and Communication, NMAMIT, Nitte,
More informationBenefits of the R&S RTO Oscilloscope's Digital Trigger. <Application Note> Products: R&S RTO Digital Oscilloscope
Benefits of the R&S RTO Oscilloscope's Digital Trigger Application Note Products: R&S RTO Digital Oscilloscope The trigger is a key element of an oscilloscope. It captures specific signal events for detailed
More informationVocoder Reference Test TELECOMMUNICATIONS INDUSTRY ASSOCIATION
TIA/EIA STANDARD ANSI/TIA/EIA-102.BABC-1999 Approved: March 16, 1999 TIA/EIA-102.BABC Project 25 Vocoder Reference Test TIA/EIA-102.BABC (Upgrade and Revision of TIA/EIA/IS-102.BABC) APRIL 1999 TELECOMMUNICATIONS
More informationLow-speed serial buses are used in wide variety of electronics products. Various low-speed buses exist in different
Low speed serial buses are widely used today in mixed-signal embedded designs for chip-to-chip communication. Their ease of implementation, low cost, and ties with legacy design blocks make them ideal
More informationInterfacing the TLC5510 Analog-to-Digital Converter to the
Application Brief SLAA070 - April 2000 Interfacing the TLC5510 Analog-to-Digital Converter to the TMS320C203 DSP Perry Miller Mixed Signal Products ABSTRACT This application report is a summary of the
More informationRe: ENSC 370 Project Physiological Signal Data Logger Functional Specifications
School of Engineering Science Simon Fraser University V5A 1S6 versatile-innovations@sfu.ca February 12, 1999 Dr. Andrew Rawicz School of Engineering Science Simon Fraser University Burnaby, BC V5A 1S6
More informationA New "Duration-Adapted TR" Waveform Capture Method Eliminates Severe Limitations
31 st Conference of the European Working Group on Acoustic Emission (EWGAE) Th.3.B.4 More Info at Open Access Database www.ndt.net/?id=17567 A New "Duration-Adapted TR" Waveform Capture Method Eliminates
More informationAdvanced Synchronization Techniques for Data Acquisition
Application Note 128 Advanced Synchronization Techniques for Data Acquisition Introduction Brad Turpin Many of today s instrumentation solutions require sophisticated timing of a variety of I/O functions
More informationMSO-28 Oscilloscope, Logic Analyzer, Spectrum Analyzer
Link Instruments Innovative Test & Measurement solutions since 1986 Store Support Oscilloscopes Logic Analyzers Pattern Generators Accessories MSO-28 Oscilloscope, Logic Analyzer, Spectrum Analyzer $ The
More informationmedlab One Channel ECG OEM Module EG 01000
medlab One Channel ECG OEM Module EG 01000 Technical Manual Copyright Medlab 2012 Version 2.4 11.06.2012 1 Version 2.4 11.06.2012 Revision: 2.0 Completely revised the document 03.10.2007 2.1 Corrected
More informationUpdate on DAQ for 12 GeV Hall C. Brad Sawatzky
Update on DAQ for 12 GeV Hall C Brad Sawatzky SHMS/HMS Trigger/Electronics H. Fenker 2 SHMS / HMS Triggers SCIN = 3/4 hodoscope planes CER = Cerenkov(s) STOF = S1 + S2 EL-Hi = SCIN + PSh_Hi EL-Lo = 2/3{SCIN,
More informationDMC550 Technical Reference
DMC550 Technical Reference 2002 DSP Development Systems DMC550 Technical Reference 504815-0001 Rev. B September 2002 SPECTRUM DIGITAL, INC. 12502 Exchange Drive, Suite 440 Stafford, TX. 77477 Tel: 281.494.4505
More informationSuperB- DCH. Servizio Ele<ronico Laboratori FrascaA
1 Outline 2 DCH FEE Constraints/Estimate & Main Blocks front- end main blocks Constraints & EsAmate Trigger rate (150 khz) Trigger/DAQ data format I/O BW Trigger Latency Minimum trigger spacing. Chamber
More informationB I O E N / Biological Signals & Data Acquisition
B I O E N 4 6 8 / 5 6 8 Lectures 1-2 Analog to Conversion Binary numbers Biological Signals & Data Acquisition In order to extract the information that may be crucial to understand a particular biological
More informationDSA-1. The Prism Sound DSA-1 is a hand-held AES/EBU Signal Analyzer and Generator.
DSA-1 The Prism Sound DSA-1 is a hand-held AES/EBU Signal Analyzer and Generator. The DSA-1 is an invaluable trouble-shooting tool for digital audio equipment and installations. It is unique as a handportable,
More informationArtisan Technology Group is your source for quality new and certified-used/pre-owned equipment
Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment FAST SHIPPING AND DELIVERY TENS OF THOUSANDS OF IN-STOCK ITEMS EQUIPMENT DEMOS HUNDREDS OF MANUFACTURERS SUPPORTED
More informationDigital Audio Design Validation and Debugging Using PGY-I2C
Digital Audio Design Validation and Debugging Using PGY-I2C Debug the toughest I 2 S challenges, from Protocol Layer to PHY Layer to Audio Content Introduction Today s digital systems from the Digital
More informationS C L M Software Requirements Specification 1.0
S C L M Software Requirements Specification 1.0 Scanning Confocal LabVIEW Microscope Martin Moene Introduction 1 Description 2 Features 7 Interfaces 17 Nonfunctional 17 Other 17 Glossary 17 Dictionary
More informationZeroplus Logic Analyzer Multi-LA Stack and LA-Oscilloscope Stack
Zeroplus Logic Analyzer Multi-LA Stack and LA-Oscilloscope Stack Preface As digital technology develops, new 3C products continuously come into the market. To help engineers to release their products earlier,
More informationAn Overview of Beam Diagnostic and Control Systems for AREAL Linac
An Overview of Beam Diagnostic and Control Systems for AREAL Linac Presenter G. Amatuni Ultrafast Beams and Applications 04-07 July 2017, CANDLE, Armenia Contents: 1. Current status of existing diagnostic
More informationPLASMA MONITOR (PT20 UVVis) USER GUIDE
Thin Film Measurement solution Software, sensors, custom development and integration PLASMA MONITOR (PT20 UVVis) USER GUIDE August 2012 Plasma monitor with VFT probe. INTRODUCTION Plasma Monitor includes
More informationBEAMAGE 3.0 KEY FEATURES BEAM DIAGNOSTICS PRELIMINARY AVAILABLE MODEL MAIN FUNCTIONS. CMOS Beam Profiling Camera
PRELIMINARY POWER DETECTORS ENERGY DETECTORS MONITORS SPECIAL PRODUCTS OEM DETECTORS THZ DETECTORS PHOTO DETECTORS HIGH POWER DETECTORS CMOS Beam Profiling Camera AVAILABLE MODEL Beamage 3.0 (⅔ in CMOS
More informationOverview. Know Your Oscilloscope. Front Panel. Rear Panel. Sharing Agilent s Resources with Engineering Educators
Know Your Oscilloscope Overview Front Panel Sharing Agilent s Resources with Engineering Educators www.educatorscorner.com Horizontal (time) controls Run control Special purpose menus/controls Trigger
More informationSony XCD V60CR cameras to inspect automotive cables
Sony XCD V60CR cameras to inspect automotive cables Crafelec application Established in France for over 14 years, CRAFELEC is specialized in automation, industrial IT, electrical and industrial maintenance.
More information